Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
B-2017-1251
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-1251 21067 MANITA CT CUPERTINO, CA 95014-5074 (362 23 042) BAY AREA UNDERPINNING INC FAIRFIELD, CA 94534 OWNER'S NAME: NG FRANKLIN YUNG-CHO AND MARY MA-LAING TRU DATE ISSUED: 07/31/2017 OWNER'S PHONE: 408-257-5699 PHONE NO: (701) 310-0602 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B• D-30 Lic. #01132 Contractor SAY AREA UNDERPINNING INC Date 11/30/2017 XBLDG _ELECT _PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with'Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: UNDERPIN A PORTION OF THE FOUNDATION WITH ECP MODEL I hereby affirm under penalty of perjury one of the following two declarations: 300 RESISTANCE PILES TO PARTIALLY RELEVEL THE FLOOR 1. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the erformance of the work for which this permit is issued. I have and will maintain Worke?s Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $19127.50 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 362 23 042 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands an will comply with all non -point source;regu tions per t Cupertino M icipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. nature Date 1 Issued by: Abby Ayende Date: 07/31/2017 I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is i. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the propert}; am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: -U I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER i. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code,, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued, I Health & Safety Code, Section 25532(a) should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, C pter 9.12 and exemption, I become subject to the Worker's Compensation provisions of the the Health & Safety Cod 5 05, 25533, and 553C , Sections 2 Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. ner or thorized agent: APPLICANT CERTIFICATION Date: Z(' I certify that I have read this application and state that the above information is NSTRUCTI QN LENDING AGE CY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date U Professional M> 1 i COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 C R,T (408) 777-3228 • FAX (408) 777-3333 • building(cD-cupertino.org ❑.NEW QONSTRU.&.QN,_, _❑_ADDITION _ _,__❑ ALTERATION / TI ❑ REVISION, / DEFERRED ORIGINAL PERMIT #. PROJECT ADDRESS APN # c � J210:67,,M, ail to .Court 3(Q2- Z3 O'TZ OWNERNAA E - -Frank Ng PHONE 4D8-2-57-56BB E 'n Fyng2928 hotmail.com STREET ADDRESS CITY, STATE, ZIP FAX !' 21067 ManitaCourt Cupertino, CA 95014 CONTACT NAME PHONE E-MAIL Clifford Tanaka 415-798-0444 c aW';' h a I e'r'@ g miai1.com STREET ADDRESS cIIY, STATE, ZIP' FAX, 16 E1 nwoad'Court Novat%, CA 94945, DOWNER OWNER-BUILDER ❑ OWNERAGENT �QCONTRACTOR ❑CONTRACTORAGENT 17 ARCHITECT ❑ENGINEER DEVELOPER TENANT CONTRACTOR'NAME LICENSE NUMBER LICENSE TYPE BUS. LIC # Steve Egloff 867128 B, Dk ! COMPANY NAME E-MAIL FAX Bay Area Underpinning, Inc. hannah@ba areaunderpinning.co' STREET ADDRESS CITY, -STATE; ZIP,PHONE' .517.0 Fulton Drive Rairfield.,'C :534 707 10-0602,' ARCHITECT/ENGINEER NAME LICENSE NUMBER. BUS: T 3C °^-itfford `-anaka -56956 COMPANYNAN19 E-MAIL FAX:' I , STREET ADDRESS CITY, STATE, ZIP ' .,:PHONE . 16 Elmwood Court Novato, CA 94945 ' 415-798-0444 DESCRIPTION. OF WORI4p �, F° 'Underpin a portion of the.foundatfdrit rith EGf Model 300-kbsiatance I?�le�s•to; artiall relevel. the:,floor. EXISTING USE PROPOSED USE CONSTR. TYPE # STORIES �- USE TYPE , DCC. SQ.FT. ;I VALUATION (s) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA.j, BATRRODM 7iITCHEN 'OTHER "'REMOTdEL AREA cREWDEL AREA . _RMODEL A%EA ; :•_POREWAREA =' ✓,T3ECK"AREA ., .:'QT`AL:IIECKifz�ItCHAREA-QARAGE'•AREA:• DETACH_ ATTACH # DWELLING UNITS: IS A SECOND UNIT 0 YES SECOND STORY ❑ YES BEING ADDED? DNO ADDITION? ONO '' ! L ,PRE-APPLICATION 0 YES IF YES, PROVIDE COPY OF Is THE BLDG AN 0 YES 'RE .IViYD $3j T iVALUAT ION: • . PLANNING APPL.# DNO PLANNING APPROVAL LETTER EICHLER HOME? 0 NO __ yz owner or authorized ent t - acf on, th co a cation d the infolmationI have p ogid d is correct. I Have re d'the Descri tion of Work and veri It:IS accutate. I a ©caner s behalf? I have lead this' Y Y rte" & P opt P l agree to ails I with all applicable,l©cal= PP pr P fY - ... � ,. P Y ardinances'and'stateiaws rel'atinfo ui[ding co eu. T auttio . e repzesentatives of Cupertinosfi enter;the ali'ove-id tified erty foriilspectronpurpilses: Signature of ApplicantiAgent; Date: i suPPLEmENTAL INFORMATION REQUIRED- New EQUIRED New SFD or Multifamily dwellings: Apply,for demolition permit for existing building(s). Demolition permit is required prior to issuance of building w permitfoz,fiew.,building. 1 is it �iItt 1' 4 . _)aornmerclalBldgs: `Provides•oc+mpletedH'a;zardousMiterlals'Disclosure r sA t �i sfi +�3i Torre If.'any HaSardous'Matefials:%are being USe&aS''part of this W.ojec _ Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. Ia�rolt lstlmrI�urerc nF � �� M�I.RIiAUNA'tEI�IT` I;r-HISA1.'Ct��'y � BldgApp 2011. d6cl revW d 06121/11 I SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 (408)777-3228• FAX(408)777-3333• buildino cupertino.orq I'ERNII;I CANNOT BE:FINALED'UNTII;: WATER-CONSERVING PLUMBING FIXTURES OWNER CERTIFICATE OF COMPLIANCE yts. COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 (408)777-3 28•FAX( 08)777-3333•buildinq a(�cuoertino.orq i Owner Name aI Permit No. 1320) 2- i1 S 4 Address 2-tO67 fr r-t"4- f -T i C-A- 9S-0 t tit Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. l No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? 0 Yes Civil Code Sections 1101.1 through 1101.8 do not apply. 0 The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of fonn. O No Go to Question 3. 3. Is water service permanently disconnected for your building? O Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. {}i No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? O No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. 3,Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form... 5. Please check ONE of the following X My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017, all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). O My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014,specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). O My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). I,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements, and that th water<c '�nservung pluyarbing fixtures comply with the requirements as indicated in the table on the following page. �- / Owner or. Owner Agent's Signature: Date: 'i/J /2 i 7 Upon completing and signing this Certificate,please return it to the Building Division in order to final your building permit. SB407 2015.doc revised 01/05/17 CLIFFORD TANAKA P.E. cawhelerftmaikcom 16 ELM WOOD COURT NOVATO,CA 94945 (415) 798-0444 Project .)_ Sheet of ( r--144-j"..3 MA Co Date Date CA.)PFAX1100 Q 61( SbvL By T p rttif b INSPECTION REPORT P( Lez-5 - C.0 /'AC-1 CAtt, LA.,) (fl-1 pc-,nevi,-5 5 nrup 6 "7,z .• LU ‘t' Er 2569 ; ito,*4 '1676117- , , f s 1 Installation Log: Model 30 ,11. Job Name: NG N I Job Address: 21067 MonicaC1 License#667128 City: State: Ca 95014 e 4 . n r: lam: 3-4f! I Utilities Check By: 811 t . - Special Notes: _ I Drive Cylinder: Yellow Enerpac Location and Driving Force-Pounds Pipe# Feet PIER#1 PIER#2 _PIER#3 PIER#4 PIER*5. PIER#6 PIER#7 PIER*8 PIER#9 PIER#10 PIER*11 ,PIER#12 PIER#13 PIER#14 PIER#15 Starter 3.5 ft 800 600 600 800 1300 1300 1300 800 , 900 No. 2 7ft 1000 1000 ! 800 1000 1800 1400 1800 1000 1500 No.3 10 54ft 1.800 .4900 4000 .1500 . .:4200 . 1500 2000 , 1000 . -2000 No.4 14ft 2500 , UG 2530 .2400 2100 1600 2700 '2130 30013 No.""5 11,5,11 zoo :31100 3580 0, 2000 X000 46011 _-2600 :3400= i Na:L6 21'ft 6000 6600 -SOO 3300 21100 =4609 No. 7 24.5 ft 4500 3000 No. 8 28 ft 4500 No. 9 31.5 ft No. 10 35ft No. 11 38.5 ft 1 No. 12 42 ft No. 13 45.5 ft No. 14 49ft .No 15 ".52.511 .: No. 16 5611 'No. 17 59.5 ft No. 18 63ff No. 19 66.5 ft No. 20 70ff No. 21 73.51E No. 22 77 ft No. 23. 80 ft No: 24 . 84 ft No. 25 87.5 ft 'No. 26 91 No. 27 94.5ft No. 28 a 98ft _ ' ia. 29 101.5ft No.30 105 ft No, 31 1O8t a g ; No. 33` 112 ft No.33 115 5,ft -No. 34 119 ft No. 35 122.5 ft No. 36 126 ft No. 37 129,5 ft No. 36 133 ft No, 39 138.5 ft No.40 1801t Coupler Used, It 1 1 1 t 0 3 0 0 0 0 Depth .21 a' ,21 ,21 . 17,5 . ,1 .5 17,6 21 17.5 ? „ -,– r:.- 'f. . .. r 3.1XI0. ' 8, -1, 3500 . 4500 °. 4$00 ;P 4396 . 4,600 ,- 3500 h' ` ;;:_ 'Final Pus234bs , 29,700 38,510 p 3.564 20,790 ' 26,730 26,730 26,730 27,324 20,596 ' 111x1 Lift PSI ,�.—,,� Lifting rc c�ins 9c„O –3,S111,41 Design Safety Factor Q ( 4i' Date.Completed: I Installer: AlexVilla a Uv rn s a` F Q Materia!Notes: Count t (12 44‘ 41w 1_,...."//1 t 300EPSkat 9 300 Brnc 0I`44 1‘'. L CI" 0 Cp,�\Fd Abby Ayende 09/19/17 09/19/17 B-2017-1603 Abby Ayende Abby Ayende 09/19/17