Loading...
B-2017-1258ri CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-1258 10551 CASTINE AVE CUPERTINO, CA 95014-1310 (326 44 035) BAY AREA SOLAR SOLUTIONS INC PLEASANTON,CA 94588 OWNER'S NAME: BHAGATWALA DHARMESH C AND SUSHMA DATE ISSUED: 08/01/2017 OWNER'S PHONE: 408-209-0298 PHONE NO: (925) 380-9500 LICENSED CONT A TOR'S D .LARATION BUILDING PERMIT INFO: License Class C-10 Lic. #928652 Contractor BAY AREA SOLAR SOLUTIONS iNC Date 02/28/2019 X BLDG —ELECT —PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: N 14 PANEL ROOF MOUNTED PV SYSTEM (4.27 KW) I hereby affirm under penalty of perjury one of the following two declarations: t. I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation: $14321.40 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction, and hereby authorize 326 44 035 representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of.this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM, LAST CALLED INSPECTION. gnature - Date 8/1/2017 Issued by: AbbyAyende Date: 08/01/2017 OWNER -BUILDER DECLARATION I hereby' affirmthat I', am exempt from the Contrac'tor's License Law for one of the RE -ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed. If a roof is i. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I' agree to remove all new materials for ' compensation, will do the work, and the structure is not intended or offered for inspection. sale,(Sec.7044, Business & Professions Code) 2' I, as owner of the property, am exclusively contracting with licensed Signature ofApplicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: $1112017 I herebyaffirm a,rm under penalty of perjury one of the following three declarations: i, I have and will maintain a Certificate of Consent to self -insure for Worker's ALL ROOF COVERINGS TO BE CLASS. "A" OR BETTER Compensation, as provided for by Section 3700 of the Labor Code, for the performance) of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. -1 have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Sectjon,3700 of the Labor Code, for the performance of the work for which this California Health &Safety Code, Sections 25505, 25533, and 25534. I will Ii ' permit's issued. maintain compliance with the Cupertino Municipal. Code, Chapter 9.12 and the 'store 3.'cn the performance of the work for which this permit is issued, I .I certify Health & Safety Code, Section 25532(a) should I or handle hazardous .. .1 shallinot,employ any person in_any manner so as to become subject to the material. Additionally, should I use equipment or devices which emit hazardous � , air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code; Chapter 9.12 and exemption, 3 become subject to the Worker's Compensation provisions of the the Health & Safety Code, Sections 25505, 25533, and 25534. Labor Code,'I must forthwith comply with such provisions or this permit shall be deemed revoked. ner or authorized agent: APPLICANT CERTIFICATION Date: 8/1/201 . I certify that I have read this application and state'that the above information is correct. I agree to bomply with all city and county; ordinances and state laws CONSTRUCTION LENDING AGENCY ,I I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, ' judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply With all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section;9.18'. I understand my plans shall be used as public records. Licensed Signature Date W/2011 professional list ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 AE CUPERTINO I (408) 777-3228 • FAX (408) 777-3333 • building()cupertino.org PROJECT ADDRESSr vi P 1 APN # n - - j U I "7'L.� - OWNER NAME a ? ops �®"VAU-hamtXki PHONE LOS- �,/� ea cSTREET ADDRESS ITYSTA ZIP FAX CONTACT NAME16 �t V` PHO ? v Jy J STREET ADDRESS ,_ ' lm itpa %a J T Aw OA qqm� '' •• ``3�, FAX VJ 1 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNERAGENT XCONTRACTOR, ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT ON R LICENSE NUMBE V 7LICENSE TYPE va, BUS. LIC # U Y r m 1L"I d'/Q l UW G V u F ' STREET RES r kIk TJYb5 UI ��P /�, �p PHONF�y,� I o �/� (�� ARCIRTECT/BNGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF 14, SED Or Duplex ❑ Multi -Family STRUCTURE: LL❑ CommercialURBAN PROJECT IN WB.DLAND INTERFACE AREA EIYes El No PROJECT IN FLOOD ZONE ElYes ElNO OLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ElOTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS: - I KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: c DESCRIPTION OF WORK RECEIVEDBY: By my signature below, I certify to each of the following/I am the pro erty owner or authorized agent to act on the property owner's behalf. I hive read this application and the information I ha a provided i correg I have rea the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating t building con tract on. I autho ' e representatives of Cupertino to enter the above-identifieddpr./oppertty" for inspection purposes. Signature of ApplicanUAge . Date: ( o 1 SUPPLEMEAL INFORMATION REQUIRED ' CJ �y OFFICE USE ONLY OVER-THE-COUNTER., pppW❑ ❑ EXPRESS U ❑ STANDARD U ,a ' ❑ LARGE w ❑ MAJOR. PVApp_2011.doc revised 03/16/11 M UZ CUPERTINO CONTRACTOR I SUBCONTRACTOR ]LIST Building Department City Of Cupertino 10300 Tone Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 Fax: 408-777-3333 *Our municipal code requires all businesses working in the city to hay NO BUILDING FINAL OR FINAL OCCUPANCY INSPEC ON GENERAL CON I IaACTOR AND AL SUBC®NTIZA O HA BUSINESS LICENSE. I am not using any subcontract rs: , Please check applicable City of Cupertino business license. WILL BE SCHEDULED UNTIL THE OBTAINED A CITY OF CUPERTINO and comp to a following information: Date SUBCONT'RACT'OR AIT BUSINESS LICENSE # -11TIRT BUSINESS LICENSE # • r fl:I� !:'I:c�� i. . 1� 1,1~'kV1',� � • • . !,I1�1, i1104��i *Our municipal code requires all businesses working in the city to hay NO BUILDING FINAL OR FINAL OCCUPANCY INSPEC ON GENERAL CON I IaACTOR AND AL SUBC®NTIZA O HA BUSINESS LICENSE. I am not using any subcontract rs: , Please check applicable City of Cupertino business license. WILL BE SCHEDULED UNTIL THE OBTAINED A CITY OF CUPERTINO and comp to a following information: Date Owner / Contractor Signature _ Date SUBCONT'RACT'OR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing' Flooring / Carpeting Linoleum / Wood G1'ass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner / Contractor Signature _ Date IF7E,L-- SMOKE / CARBON MONOXIDE ALARMSP3-14-05' OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinci cupertino.orq :PEP:PEPIrf CANNOT.B 'FIN at).UNTIL;°THIS CERTIEiCATS;HAS BEEN COMPLETED,SI N + ,AND RETURNED TO rliF DIVISION. PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314,2016 CBC Sections 420 6 and 9072.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000 00,CRC Section R314 and CBC Sections 907.2.11.5 and 420 6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations. AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of X X the bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420 6 and shall be approved by the Office of the State Fire Marshal. Power Supply In dwelling units with no commercial power supply, alarm(s)may be solely battery operated. In existing dwelling units,alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.11 4 and 420 6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property,I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below /�,j Address. /0 ,� J 5 - Permit No. OD*. l 9453Specify Number of Alarms: #Smoke Alarms: MEI #Carbon Monoxide Detectors. I have read and agree to comply r1 ,e terms and conditions of this statement Owner(or Owner Agent's)Name: SignaturesV ' .�• fig.1 17 Date: . .. .. . (. Contractor Name: Signature Lic.# Date: Smoke and CO fonn.doc revised 12/15/16 Lt � F � -' WATER-CONSERVING PLUMBING FIXTURES fr - OWNER CERTIFICATE OF COMPLIANCE 14, COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 44 CUPERTINO 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 f (40 )777-3 8-•'FAX(408)777-3333•buildinq(u�cuoertino.orq ' Owner Name A0,, ,,v, � Permit No. T14—I - Address 10 S `�I, C4{ - . L j' 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Qls-l\To Go to Question 2. 2. Does your real property have a licensed plumber certifying that,due to the age or configuration of the property or its plumbing,installation of water-conserving plumbing fixtures is not technically feasible? ! ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. 711r-No Go to Question 3. 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of fon-n. E-No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ! ' ❑ No My real property is built and available for use or occupancy after January 1, 1994. A Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. P ase check ONE of the following: My proer is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014,building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures throughout the building.On or before January 1,2017,all non- compliant plumbing fixtures shall be replaced with water-conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). ❑ My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after Jannaiy 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1,2019,all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). 0 My property is a commercial real property. See Civil Code Section 1101.5. On and after January 1,2014,specified building alterations or improvements shall require non-compliant plumbing fixtures to be replaced with water-conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building(regardless of whether property undergoes alterations or improvements). I,as the owner or owner's agent of this property,certify under penalty of perjury that non-compliant plumbing fixtures will be replaced prior to date specified above with water-conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8,the current California Plumbing Code and California Green Building Standards Code,and manufacturer's installation requirements, and that the water-conserving plumbing fixtures comply with the requirements as indicated in the table on the following page. C Owner or Owner Agent's Signature: ? ` Dater -` / 110111.— Upon completing and signing this Certificate,please v°.., it to Building Division in order to final your b ,,Iding permit. SB407 2015.doc revised 01/05/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS6700 Santa Rita Road #E, Pleasanton, CA 94588Phone: (888) 888-0711CSLB #928652 (B) EXP. 02/28/2017X____________ ______________ISSUED FOR: PERMIT DATE: Solar Photovoltaic System7/26/2017 DHARMESH BHAGATWALA10551 CASTINE AVENUECUPERTINO, CA, 95014 PV-1 PROJECT INFORMATION VICINITY MAP SHEET INDEX APPLICABLE CODES PLAN SET LEGEND SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR LOAD CENTER INVERTER SUB AC DC SLC INV JUNCTION BOXJB COMBINER BOXCB ABBREVIATIONS EXTERIOR INTERIOR EXT INT NEW(N) EXISTING(E) ELECTRICAL METALLIC TUBINGEMT RIGID METALLIC TUBINGRMT VOLTAGE OPEN CIRCUITVOC VOLTAGE AT MAX. POWERVMP SHORT CIRCUIT CURRENTISC CURRENT AT MAX. POWERIMP AHJ NOTES PV MONITORING METERM NOT TO SCALENTS OCCUPANCY: R-3 CONSTRUCTION TYPE: VB UNSPRINKLERED MAIN SERVICE PANELMSP PROJECT INFORMATION ALL WORK TO COMPLY WITH THE FOLLOWING CODES: 2016 CA BUILDING CODE 2016 CA RESIDENTIAL CODE 2016 CA MECHANICAL CODE 2016 CA ELECTRICAL CODE 2016 CA GREEN CODE 2016 CA PLUMBING CODE 2016 CA ENERGY CODE 2016 CA FIRE CODE PV-1 PROJECT INFORMATION PV-1A SITE PLAN, HOUSE PHOTO PV-2 ROOF PLAN PV-2A ATTACHMENT DETAILS PV-3 ELECTRICAL LINE DIAGRAM & ELECTRICAL CALCULATIONS PV-3A ELECTRICAL NOTES PV-4 & 4A REQUIRED SIGNAGE ENPHASE AC SOLAR PVENCOMBINER BOX CITY PERFORMANCEPM MAIN BREAKER ONLYUM/MB UTILITY METER & METER RAPID SHUTDOWN BOXRS 14 X 305 W LG Electronics LG305N1C-G4 ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 1 X 3800 W SolarEdge Technologies SE3800H-US (240V) 14 X 400 W SolarEdge Technologies P400 Power Optimizer SYSTEM SIZE: 4.270 kW DC STC, 3.762 kW AC ARRAY AREA: 248 SF AHJ: CITY OF CUPERTINO APN: 326-440-35 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA 95014 PROJECT SITE Arnold Hom 08/01/17 08/01/17 B-2017-1258 Abby Ayende 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 SCALE: 1":15'-0" N SCALE: N.T.S. HOUSE PHOTO SITE PLAN PV-1A SITE PLAN, HOUSE PHOTO ARRAY LOCATION WITH BUILT IN RAPID SHUTDOWN OPTIMIZER LOCATED AT EACH PANEL STRING # OF PANELS TILT, AZIMUTH 1 14 18°, 180° TOTAL # OF PANELS 14 (E) ONE-STORY HOUSE (E) DRIVEWAY (N) SOLAR PV ARRAY PER TABLE BELOW SEE PV-2 FOR ROOFTOP EQUIPMENT CALLOUTS AND ROOF AND ARRAY DIMENSIONS. FIRE ACCESS POINT 1 2 3 4 SITE PLAN LEGEND 1 2 3 4 24'-3" 5'-11" 22'-6" 6'-10" 112'-0" 79'-1" 112'-0" 79'-1" CASTINE AVENUE PL PL PL PL MSP AC INV SUB 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Arnold Hom 08/01/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 SCALE: 1":10'-0" ROOF PLAN N ARRAY & ROOF INFO MODULE TYPE, DIMENSIONS & WEIGHT PV-2 ROOF PLAN WITH BUILT IN RAPID SHUTDOWN OPTIMIZER LOCATED AT EACH PANEL 1 2 CONC. W TILE CONC. W TILE 2x6 RAFTERS @ 24" o.c 2x6 RAFTERS @ 24" o.c 180 180 18 18 301 252 180 180 18 18 123.9 88.5 41.2% 35.1% 7 5 72 72 Roof Plane Roof Type: Roof Framing: Roof Azimuth (deg): Roof Slope (deg): Roof Area (sf): Array Azimuth (deg): Array Tilt (deg): Array Area (sf): % Coverage of Roof # of Panels Attachment spacing (in): PANEL TYPE: LG305N1C-G4 PANEL WEIGHT: 37.48 LB PANEL DIMENSIONS: 64.57 IN. X 39.37 IN. PANEL AREA: 17.70 SF UNIT WEIGHT OF PANELS: 37.48LB/17.7SF = 2.12 PSF OPTIMIZER & RACKING 0.34 PSF AREA PER ATTACHMENT: 6'X2.69' = 16.1 SF WEIGHT PER ATTACHMENT: 16.1SFX2.46PSF = 43.5 LB 3 CONC. W TILE 2x6 RAFTERS @ 24" o.c 180 18 382 180 18 35.4 9.3% 2 72 ALL ARRAY AND ROOF INFORMATION IS SHOWN TO THE RIGHT INCLUDING FRAMING AND ATTACHMENT SPACING. Roof Plane Roof Type: Roof Framing: Roof Azimuth (deg): Roof Slope (deg): Roof Area (sf): Array Azimuth (deg): Array Tilt (deg): Array Area (sf): % Coverage of Roof # of Panels Attachment spacing (in): R1 R2 R3 CONDUIT SHALL BE EMT CONDUIT (EXTERIOR) OR EMT OR FMC AS AHJ ALLOWS (INTERIOR), CONTRACTOR TO RUN CONDUIT ON ROOF AND UNDER EAVES OR WITHIN ATTIC. CONDUIT RUN TO BE DETERMINED AT THE TIME OF INSTALL. ANY EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE. FIRE ACCESS POINT 1 2 3 ROOF PLAN LEGEND (E) INTERIOR RAFTER SUPPORT (E) EXTERIOR WALL 1 2 3 4 4 (N) CONDUIT ROUTE MSP AC INV SUB JB JB JB (E) PLUMBING VENT (E) ROOF VENT (E) CHIMNEY 5 6 7 8 (E) SKYLIGHT 5 6 8 7 11'-8" 3'-0" 1'-7" 3'-0" 3'-0" 1'-7" 1'-6" 3'-0" 3'-0" 1'-6" 7'-8" 7'-8" 1'-6" 5'-11" 5'-11" 7'-10" 7'-10" 1'-6" Arnold Hom 08/01/17 (E) ROOF FRAMING, SEE ROOF INFO M1 SEALANT PENETRATION SEALED W/ (2) 5/16" STAINLESS STEEL LAG BOLT MIN. 2.5" BOLT AND NUT ALUMINUM "L" BRACKET W/ 3/8" PV MODULES MATCH (E) ROOF SLOPE UNIRAC RAILS MOUNT "W" TILE REPLACEMENT 614 "1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 PV-2A ATTACHMENT DETAILS SCALE: 1/2" = 1'-0" ATTACHMENT DETAIL Arnold Hom 08/01/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 SINGLE LINE DIAGRAM SCALE: N.T.S. ELECTRICAL SINGLE LINE DIAGRAM 600 V, NEMA 3R W/ EUROSTRIP OR POLARIS IT CONNECTORS JUNCTION BOX A B C ELECTRICAL EQUIPMENT CALLOUTS STRINGS CONNECTED IN PARALLEL SEE PV-3A FOR ELECTRICAL NOTES SOLAREDGE POWER OPTIMIZER P400 (240V) MAX DC VOLTAGE: 80V DC VOLTAGE INPUT RANGE: 8-80V @ 240V PEAK POWER TRACKING VOLTAGE: 8-80V @ 240V AC NOMINAL VOLTAGE/RANGE: 5-60 @ 240V MAX AC OUTPUT CURRENT: 15A CEC WEIGHTED EFFICIENCY: 98.8% @ 240V PV BREAKER IS TO BE LOCATED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. PV-3 TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1PH, 120/240V, 3W BOND TO EXISTING UFER IRREVERSIBLE GROUNDING CONNECTION NO MAIN BREAKER - RULE OF SIX C B STRINGS CONNECTED IN PARALLEL @ INVERTER JB A LOW MEAN TEMP PER ASHRAE HANDBOOK MFR VOLTAGE TEMP COEFFICIENT (oC) VOLTAGE LOW TEMP. CORR. (oC) HIGH AMBIENT TEMP (oC) CONDUIT HEIGHT (in) ROOF TOP ADDED TEMP PER Table 310.15(B)(3)© (oC) ADJUSTED TEMP TEMP CORRECTION ROOF 0 -0.28 1.07 32 0.5-3.5 22 54 .76 WALL 0 32 N/A 0 32 .96 4.270kW DC STC, 3.762 kW AC SOLAR ARRAY 14 LG Electronics 305W MODULES TOTAL MAX PV VOLTAGE & CURRENT CALCS: RECORD LOW TEMP (˚C): (PER ASHRAE HANDBOOK) TEMP COEFFICIENT (Voc) PER MANUFACTURER: -0.28%/C VOLTAGE CORRECTION: 1.07 Vcorrection X Voptm 1.07* 350 = 374.5V OUTPUT FROM POWER OPTIMIZER PER STRING: 12.2A 1.25 X Iopt 1.25 * 12.2 = 15.25A WIRE TAG # CONDUIT WIRE QTY (CARRY CURRENT) WIRE GAUGE (AWG) WIRE TYPE WIRE LENGTH (FEET) TEMP RATING: WIRE LOCATION ADJUSTED WIRE TEMP WIRE AMP TEMP CORRECTION PER TABLE 310.15(B)(2)(a): CONDUIT FILL PER Table 310.15(B)(3)(a): WIRE OCP: TERMINAL 75oC RATING STRINGS PER SET OF WIRES (DC) OR # 0F INVERTERS: SHORT CIRCUIT CURRENT (DC) OR AC OUTPUT CEC 690.8(A) CEC 690.8(B) STRING AMPS GROUND SIZE GROUND TYPE OCPD CHECK 1 NONE 2 10 PV WIRE 15 90°C ROOF 54 40 X 0.76 X 1 = 30.4 35 1 X 12.20 X 1.25 X 1 = 15.25 #6 SBC NONE 2 3/4" EMT 2 10 THWN-2 80 90°C ROOF 54 40 X 0.76 X 1 = 30.4 35 1 X 12.20 X 1.25 X 1 = 15.25 #8 THWN-2 NONE 3 3/4" EMT 3 10 THWN-2 20 90°C WALL 32 40 X 0.96 X 1 = 38.4 35 1 X 16.00 X 1.25 X 1 = 20 #8 THWN-2 20A 2P PANEL DECAL LG Electronics LG305N1C-G4 305W Vmp= 32.5V Voc= 40.1V Isc= 9.93A Imp= 9.39A CEC PTC POWER=284.4W SolarEdge Technologies SE3800H-US (240V) INVERTER MAX DC VOLTAGE: 480V DC VOLTAGE INPUT RANGE: 380-480V @240V PEAK POWER TRACKING VOLTAGE: 380-480V @240V AC NOMINAL VOLTAGE/RANGE: 211-264V @240V MAX AC OUTPUT CURRENT: 16A CEC WEIGHTED EFFICIENCY: 99% @240V 3.8kW INVERTER UNGROUNDED SOLAREDGE TECHNOLOGIES SE3800H-US (240V) (240V) INVERTER 240 VAC, 16 A NEMA 3R, UL LISTED, (WITH INTEGRATED DC DISCONNECT) EQUIPPED WITH RAPID SHUTDOWN KIT (E) 200A MAIN SERVICE PANEL NOT CENTER FED AC DISCONNECT 240 VAC, 30A NEMA 3R, UL LISTED SUB 120% RULE BUS BAR MAIN BREAKER ALLOWED MAX PV OCPD 125 125 25 STRING # OF PANELS TILT, AZIMUTH 1 14 18°, 180° TOTAL # OF PANELS 14 STRING W/ 1 POWER OPTIMIZER PER PANEL 1 (E) 125A SUB PANEL (E) (3) #2 THWN-2 & (1) #8 GROUND 2-POLE 20A PV BREAKER, BACKFED EXISTING 125A SUB PANEL BREAKER Arnold Hom 08/01/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 PV-3A ELECTRICAL NOTES ELECTRICAL NOTES ADDITIONAL AHJ REQUIRED ELECTRICAL NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES PER CEC 690.9 (A) RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ UNIRAC INTEGRATED GROUND. MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS 1. PV ARRAYS ARE PER SINGLE LINE. 2. PV ARRAY WIRING TO JUNCTION IS #10 AWG PV WIRE W/ FIELD INSTALLED MC CONNECTORS TO INTERFACE W/ MODULES. 3. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 4. PV POWER SOURCE DISCONNECT (INTEGRATED) RATED AT 36 AMPS, 600Vdc, NEMA 3R RAINPROOF. 5. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER CEC 250.58. 6. WHEN REQUIRED, GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM PROTECTION OF BARE ARMOR SHEATHED CABLE FOR ALL CONDUCTOR SIZES. 7. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 8. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. 9. INVERTER SHALL BE PER ATTACHED CUT SHEET. 10. AC DISCONNECT SHALL BE PER SINGLE LINE. 11. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO CEC 690. 12. POLE OF PV ARRAY REFERENCED TO GROUND AT THE INVERTER IN SINGLE LINE. 13. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 14. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% 15. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 16. ALL WORK TO COMPLY WITH 2016 CALIFORNIA ELECTRIC CODE, 2016 CALIFORNIA BUILDING CODE 17. D.C. ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSIBLE COMBINER BOX OR FUSIBLE DC DISCONNECT MEANS. 18. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 19. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 20. CONDUCTORS ON ROOF ARE TO BE 1/2" TO 3" OFF OF THE ROOF SURFACE. 21. GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. 22. PV WIRES UTILIZED IN SYSTEM ARE UL-4703 COMPLIANT. 23. ON RESIDENTIAL ROOF INSTALLATIONS ALL RACKING AND MODULES ARE UL2703 COMPLIANT 24. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IEDNTIFED AS WHITE. 25. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE SMALLER THAN 14 AWG. 26. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. GROUNDING: UNIRAC INTEGRATED CLAMP MODEL # 30-20-27-C UL LISTED #2703 Arnold Hom 08/01/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 PV-4 REQUIRED SIGNAGE ON THE FACE OF THE MAIN SERVICE DISCONNECT PER NEC 690.15 & NEC 690.13(B): CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES CRC R331.2 & CFC 605.11.1: WARNING: PHOTOVOLTAIC POWER SOURCE MARKING SHALL BE REFLECTIVE AND PLACED EVERY 10 FEET AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND AT ALL PV COMBINER AND JUNCTION BOXES. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH APPROVED ADHESIVE. MINIMUM OF 3/8" HIGH WHITE LETTERING ON RED BACKGROUND. LOCATED AT BACKFED BREAKER. CEC 690.64 AND 705.12(D)(3)(4)(b) PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC 690.35(F). WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL ALSO HAVE LABEL IDENTIFIED EVERY 10 FEET - AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. WARNING INVERTER CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. ON FACE OF THE SERVICE METER PANEL PER CEC 690.54 & CEC 705.12(D)(4): WARNING DUAL POWER SOURCE. SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM ON FACE OF THE SERVICE METER PANEL PER CEC 690.56 (C): PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN ADJACENT TO THE MAIN SERVICE DISCONNECT PER NEC 690.15 & NEC 690.13(B): MAIN PHOTOVOLTAIC SYSTEM DISCONNECT SIGNAGE AT CONDUIT & BOXES: SIGNAGE AT MAIN SERVICE PANEL: 1 MSP1 FRONT OF HOME CAUTION SERVICE POINT & UTILITY METERING (N) PV DISCONNECT (N) PV INVERTER (N) SOLAR ARRAY YOU ARE HERE CASTINE AVENUE 10551 CASTINE AVENUE, CUPERTINO, CA 95014 MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL: MSP2 MSP3 MSP4 MSP5 MSP6 2 RATED AC OUTPUT CURRENT = 16A AC NORMAL OPERATING VOLTAGE = 240V (E) SUB PANEL INSIDE GARAGE Arnold Hom 08/01/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B) EXP. 02/28/2017 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 7/26/2017 DHARMESH BHAGATWALA 10551 CASTINE AVENUE CUPERTINO, CA, 95014 PV-4A REQUIRED SIGNAGE ON DISCONNECTING MEANS IN 1 4" HIGH LETTERING PER CEC 690.17 (E). WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL FOR SOLAR AC DISCONNECT PER NEC 690.15 & NEC 690.13(B): PHOTOVOLTAIC AC DISCONNECT ON FACE OF THE UTILITY AC DISCONNECT: PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION ON FACE OF THE UTILITY AC DISCONNECT PER NEC 110.27(C): WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL. ON FACE OF THE AC DISCONNECT PER CEC 690.54: SIGNAGE AT AC DISCONNECT: C1 AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING PER CEC 690.5(C): WARNING ELECTRICAL SHOCK HAZARD. IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUNDED AND ENERGIZED. SIGNAGE AT GROUND FAULT INDICATOR: C2 C3 C4 C5 B1 RATED AC OUTPUT CURRENT = 16A AC NORMAL OPERATING VOLTAGE = 240V PV SYSTEM AC DISCONNECT SIGNAGE AT INVERTER: LABEL FOR SOLAR DC DISCONNECT PER NEC 690.15 & NEC 690.13(B) : PHOTOVOLTAIC DC DISCONNECT LABEL FOR INVERTER PER CEC 690.7 (E): WARNING BIPOLAR PHOTOVOLTAIC ARRAY. DISCONNECTION OF NEUTRAL OF GROUNDED CONDUCTORS MAY RESULT IN OVERVOLTAGE ON ARRAY OR INVERTER B2 B3 B4 ON ROOFTOP JUNCTION BOX & SHUTDOWN BOX NEC 690.17(E): WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. __________________________________________________________________ DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ON RAPID SHUTDOWN SWITCH LOCATED ON OR WITHIN 3' FROM SWITCH, IN 3 8" LETTERS IN WHITE ON RED BACKGROUND RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SIGNAGE AT RAPID SHUTDOWN EQUIPMENT: D1 D2 LABEL FOR SOLAREDGE TECHNOLOGIES SE3800H-US (240V) INVERTER PER CEC 690.53: GRID-TIED PHOTOVOLTAIC POWER SOURCE & DC DISCONNECT RATED MAXIMUM POWER-POINT CURRENT = 12.20 A RATED MAXIMUM POWER-POINT VOLTAGE = 350 V MAX SYSTEM VOLTAGE = 374.5 V SHORT-CIRCUIT CURRENT = 15.3 A MAX INVERTER OUTPUT = 3.8 kW, 16 A, 240VAC Arnold Hom 08/01/17 LG’s new module, LG NeON™ 2, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. LG NeON™ 2 demonstrates LG’s efforts to increase customer’s values performance under real environment, and aesthetic design suitable for roofs. Enhanced Performance Warranty LG NeON™ 2 has an enhanced performance warranty. The annual degradation has fallen from -0.7%/yr to -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p more output than the previous LG NeON™ modules. High Power Output Compared with previous models, the LG NeON™ 2 Aesthetic Roof LG NeON™ 2 has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may help increase the value of a property with its modern design. Double-Sided Cell Structure The rear of the cell used in LG NeON™ 2 will contribute to the rear of the module is reabsorbed to generate a great amount of additional power. Better Performance on a Sunny Day LG NeON™ 2 now performs better on sunny days thanks Outstanding Durability With its newly reinforced frame design, LG has extended the warranty of the LG NeON™ 2 for an additional 2 years. Additionally, LG NeON™ 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. LG305N1C-G4 L L About LG Electronics Innovation for a Better Life 60 cell LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Group’s rich experience in semi-conductor, LCD, hmjrnxyw~0 fsi rfyjwnfqx nsizxyw~/ bj xzhhjxxkzqq~ wjqjfxji Ņwst Mono X® series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, NeON™ (previously known as Mono X® NeON) & 2015 NeON2 with CELLO technology won “Intersolar Award”, which proved LG is the leader of innovation in the industry. LG305N1C-G4 Characteristic Curves North America Solar Business Team LG Electronics U.S.A. Inc 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: lg.solar@lge.com www.lgsolarusa.com DS-N2-60-C-G-F-EN-50427 Copyright © 2016 LG Electronics. All rights reserved. 01/01/2016 Innovation for a Better Life Electrical Properties (NOCT*) Module Type Maximum Power (Pmax) MPP Voltage (Vmpp) MPP Current (Impp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 305 W 223 29.7 7.49 37.1 8.01 * NOCT (Nominal Operating Cell Temperature): Irradiance 800 W/m2, ambient temperature 20 °C, wind speed 1 m/s Electrical Properties (STC *) Module Type MPP Voltage (Vmpp) MPP Current (Impp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Operating Temperature (°C) Maximum System Voltage (V) Maximum Series Fuse Rating (A) Power Tolerance (%) -40 ~ +90 1000 20 0 ~ +3 305 W 32.5 9.39 40.1 9.93 18.6 * STC (Standard Test Condition): Irradiance 1000 W/m², Module Temperature 25 °C, AM 1.5 * The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. Mechanical Properties Cells Cell Vendor Cell Type Cell Dimensions # of Busbar Dimensions (L x W x H) Front Load Rear Load Weight Connector Type Junction Box Length of Cables Glass Frame 6 x 10 LG Monocrystalline / N-type 156.75 x 156.75 mm / 6 inches 12 (Multi Wire Busbar) 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch 6000 Pa / 125 psf 5400 Pa / 113 psf 17.0 ± 0.5 kg / 37.48 ± 1.1 lbs MC4, MC4 Compatible, IP67 IP67 with 3 Bypass Diodes 2 x 1000 mm / 2 x 39.37 inch High Transmission Tempered Glass Anodized Aluminum Temperature Characteristics NOCT Pmpp Voc Isc 46 ± 3 °C -0.38 %/°C -0.28 %/°C 0.03 %/°C Module Fire Performance (USA) Fire Rating (for CANADA) Product Warranty Output Warranty of Pmax IEC 61215, IEC 61730-1/-2 IEC 62716 (Ammonia Test) IEC 61701 (Salt Mist Corrosion Test) ISO 9001 UL 1703 Type 2 (UL 1703) Class C (ULC/ORD C1703) 12 years Linear warranty* * 1) 1st year: 98%, 2) After 2nd year: 0.6%p annual degradation, 3) 83.6% for 25 years Current (A) Isc, Voc, Pmax (%) Voltage (V) Temperature (°C) 10.00 1000W 600W 200W 800W 400W 6.00 2.00 8.00 4.00 0.00 10.00 30.00 20.00 40.00 15.00 35.00 25.00 45.00 5.00 Isc Voc Pmax 140 60 100 20 120 40 80 0 -40 90 5 -25 50 75 Dimensions (mm/in) * The distance between the center of the mounting/grounding holes. Detail X Detail Y Detail Z Long side frame 7.5 / 0.30 4.0 / 0.16 5.5 / 0.22 R1.5 / R0.06 4.0 / 0.16 Ø8.2 / Ø0.32 10.0 / 0.39 29.0 / 1.14 40.0 / 1.57 10.0 / 0.39 29.0 / 1.14 40.0 / 1.57 Short side frame 40 / 1.57 270 / 0.63 170 / 6.69 105 / 4.13 (Z view) Ø8.2 / Ø0.32 Mounting holes(8ea) (X view) 5.5 x 4.0 / 0.22 x 0.16 Drain holes(4ea) Ø4.3 / Ø0.17 Grounding holes(12ea) 1000 / 39.37 (Distance between mounting holes) (Size of short side) 1640 / 64.57 (Size of long side) 960 / 37.80 1100 / 43.31 Junction box 1000 / 39.37 Cable length (Distance between mounting holes) 1300 / 52.18 (Distance between mounting holes) Drain holes(4ea) (Y view) 7.5 x 4.0 / 0.3 x 0.16 Arnold Hom 08/01/17 SolarEdge Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US INVERTERS www.solaredge.us h^ͳEͳ'ZDEzͳ/d>zͳ&ZEͳ:WEͳ,/Eͳh^dZ>/ͳd, Ed,Z>E^ͳh<ͳ/^Z>ͳdhZ<zͳ^Khd, &Z/ͳh>'Z/ Optimized installation with HD-Wave technology ^ƉĞĐŝĮĐĂůůLJ ĚĞƐŝŐŶĞĚ ƚŽ ǁŽƌŬ ǁŝƚŚ ƉŽǁĞƌ ŽƉƟŵŝnjĞƌƐ ZĞĐŽƌĚͲďƌĞĂŬŝŶŐ ĞĸĐŝĞŶĐLJ /ŶƚĞŐƌĂƚĞĚ ĂƌĐ ĨĂƵůƚ ƉƌŽƚĞĐƟŽŶ ĨŽƌ E ϮϬϭϭ ϲϵϬ͘ϭϭ ĂŶĚ ŝŶƚĞŐƌĂƚĞĚ ƌĂƉŝĚ ƐŚƵƚĚŽǁŶ ĨŽƌ E ϮϬϭϰ ϲϵϬ͘ϭϮ džƚƌĞŵĞůLJ ƐŵĂůů ,ŝŐŚ ƌĞůŝĂďŝůŝƚLJ ǁŝƚŚŽƵƚ ĂŶLJ ĞůĞĐƚƌŽůLJƟĐ ĐĂƉĂĐŝƚŽƌƐ ƵŝůƚͲŝŶ ŵŽĚƵůĞͲůĞǀĞů ŵŽŶŝƚŽƌŝŶŐ KƵƚĚŽŽƌ ĂŶĚ ŝŶĚŽŽƌ ŝŶƐƚĂůůĂƟŽŶ KƉƟŽŶĂů͗ ZĞǀĞŶƵĞ ŐƌĂĚĞ ĚĂƚĂ͕ E^/ ϭϮ͘ϮϬ ůĂƐƐ Ϭ͘ϱ ;Ϭ͘ϱй ĂĐĐƵƌĂĐLJͿ 12-25 ͘ϭϮ © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2017. V.01. Subject to change without notice. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US ^ϯϬϬϬ,ͳh^ ^ϯϴϬϬ,ͳh^ ^ϱϬϬϬ,ͳh^ ^ϲϬϬϬ,ͳh^ ^ϳϲϬϬ,ͳh^ KhdWhd ZĂƚĞĚ  WŽǁĞƌ KƵƚƉƵƚ ϯϬϬϬ ϯϴϬϬ ϱϬϬϬ ϲϬϬϬ ϳϲϬϬ s DĂdž͘  WŽǁĞƌ KƵƚƉƵƚ ϯϬϬϬ ϯϴϬϬ ϱϬϬϬ ϲϬϬϬ ϳϲϬϬ s  KƵƚƉƵƚ sŽůƚĂŐĞ DŝŶ͘ͲEŽŵ͘ͲDĂdž͘ ;ϭϴϯ Ͳ ϮϬϴ Ͳ ϮϮϵͿ  ac  KƵƚƉƵƚ sŽůƚĂŐĞ DŝŶ͘ͲEŽŵ͘ͲDĂdž͘ ;Ϯϭϭ Ͳ ϮϰϬ Ͳ ϮϲϰͿ Vac  &ƌĞƋƵĞŶĐLJ ;EŽŵŝŶĂůͿ ϱϵ͘ϯ Ͳ ϲϬ Ͳ ϲϬ͘ϱ;ϭͿ ,nj DĂdžŝŵƵŵ ŽŶƟŶƵŽƵƐ KƵƚƉƵƚ ƵƌƌĞŶƚ ϮϬϴs Ϯϰ  DĂdžŝŵƵŵ ŽŶƟŶƵŽƵƐ KƵƚƉƵƚ ƵƌƌĞŶƚ ϮϰϬs ϭϮ͘ϱ ϭϲ Ϯϭ Ϯϱ ϯϮ  '&/ dŚƌĞƐŚŽůĚ hƟůŝƚLJ DŽŶŝƚŽƌŝŶŐ͕ /ƐůĂŶĚŝŶŐ WƌŽƚĞĐƟŽŶ͕ ŽƵŶƚƌLJ ŽŶĮŐƵƌĂďůĞ dŚƌĞƐŚŽůĚƐ Yes /EWhd DĂdžŝŵƵŵ  WŽǁĞƌ ϰϲϱϬ ϱϵϬϬ ϳϳϱϬ ϵϯϬϬ ϭϭϴϬϬ W dƌĂŶƐĨŽƌŵĞƌͲůĞƐƐ͕ hŶŐƌŽƵŶĚĞĚ Yes DĂdžŝŵƵŵ /ŶƉƵƚ sŽůƚĂŐĞ ϰϴϬ Vdc EŽŵŝŶĂů  /ŶƉƵƚ sŽůƚĂŐĞ ϯϴϬ ϰϬϬ Vdc DĂdžŝŵƵŵ /ŶƉƵƚ ƵƌƌĞŶƚ ϮϬϴs ϭϱ͘ϱ ĚĐ DĂdžŝŵƵŵ /ŶƉƵƚ ƵƌƌĞŶƚ ϮϰϬs ϴ͘ϱ ϭϬ͘ϱ ϭϯ͘ϱ ϭϲ͘ϱ ϮϬ ĚĐ DĂdž͘ /ŶƉƵƚ ^ŚŽƌƚ ŝƌĐƵŝƚ ƵƌƌĞŶƚ ϰϱ ĚĐ ZĞǀĞƌƐĞͲWŽůĂƌŝƚLJ WƌŽƚĞĐƟŽŶ Yes 'ƌŽƵŶĚͲ&ĂƵůƚ /ƐŽůĂƟŽŶ ĞƚĞĐƟŽŶ ϲϬϬŬ ^ĞŶƐŝƟǀŝƚLJ DĂdžŝŵƵŵ /ŶǀĞƌƚĞƌ ĸĐŝĞŶĐLJ ϵϵ ϵϵ͘Ϯ й  tĞŝŐŚƚĞĚ ĸĐŝĞŶĐLJ ϵϵ й EŝŐŚƫŵĞ WŽǁĞƌ ŽŶƐƵŵƉƟŽŶ ф Ϯ͘ϱ W ^>&ͳ^h^d/E/E' WKtZ Khd>d ΈKWd/KE>Ή EŽŵŝŶĂů KƵƚƉƵƚ sŽůƚĂŐĞ ϭϮϬ V DĂdžŝŵƵŵ KƵƚƉƵƚ WŽǁĞƌ ϭϱϬϬ;ϮͿ W džƚĞƌŶĂů KƵƚůĞƚ ǁŝƚŚ '&/ Yes /d/KE> &dhZ^ ^ƵƉƉŽƌƚĞĚ ŽŵŵƵŶŝĐĂƟŽŶ /ŶƚĞƌĨĂĐĞƐ Z^ϰϴϱ͕ ƚŚĞƌŶĞƚ͕ ŝŐĞĞ ;ŽƉƟŽŶĂůͿ͕ ĞůůƵůĂƌ ;ŽƉƟŽŶĂůͿ ZĞǀĞŶƵĞ 'ƌĂĚĞ ĂƚĂ͕ E^/ ϭϮ͘ϮϬ KƉƟŽŶĂů;ϯͿ ZĂƉŝĚ ^ŚƵƚĚŽǁŶ Ͳ E ϮϬϭϰ ϲϵϬ͘ϭϮ ƵƚŽŵĂƟĐ ZĂƉŝĚ ^ŚƵƚĚŽǁŶ ƵƉŽŶ  'ƌŝĚ ŝƐĐŽŶŶĞĐƚ ^dEZ KDW>/E ^ĂĨĞƚLJ h>ϭϳϰϭ͕ h>ϭϲϵϵ͕ ^ ϮϮ͘Ϯ͕ ĂŶĂĚŝĂŶ &/ ĂĐĐŽƌĚŝŶŐ ƚŽ d͘/͘>͘ DͲϬϳ 'ƌŝĚ ŽŶŶĞĐƟŽŶ ^ƚĂŶĚĂƌĚƐ /ϭϱϰϳ͕ ZƵůĞ Ϯϭ͕ ZƵůĞϭϰ ;,/Ϳ ŵŝƐƐŝŽŶƐ & WĂƌƚ ϭϱ ůĂƐƐ  /E^d>>d/KE ^W/&/d/KE^  KƵƚƉƵƚ ŽŶĚƵŝƚ ^ŝnjĞ ͬ t' ZĂŶŐĞ Ϭ͘ϳϱͲϭ͟ ŽŶĚƵŝƚ ͬ ϭϰͲϲ t'  /ŶƉƵƚ ŽŶĚƵŝƚ ^ŝnjĞ ͬ η ŽĨ ^ƚƌŝŶŐƐ ͬ t' ZĂŶŐĞ Ϭ͘ϳϱͲϭ͟ ŽŶĚƵŝƚ ͬϭͲϮ ƐƚƌŝŶŐƐ ͬ ϭϰͲϲ t' ŝŵĞŶƐŝŽŶƐ ǁŝƚŚ ^ĂĨĞƚLJ ^ǁŝƚĐŚ ;,džtdžͿ ϭϳ͘ϳ dž ϭϰ͘ϲ dž ϲ͘ϴ ͬ ϰϱϬ dž ϯϳϬ dž ϭϳϰ ŝŶ ͬ ŵŵ tĞŝŐŚƚ ǁŝƚŚ ^ĂĨĞƚLJ ^ǁŝƚĐŚ Ϯϱ͘ϯ ͬ ϭϭ͘ϱ ůď ͬ ŬŐ EŽŝƐĞ ф Ϯϱ Ě ŽŽůŝŶŐ EĂƚƵƌĂů ŽŶǀĞĐƟŽŶ KƉĞƌĂƟŶŐ dĞŵƉĞƌĂƚƵƌĞ ZĂŶŐĞ Ͳϭϯ ƚŽ нϭϰϬ ͬ ͲϮϱ ƚŽ нϲϬ;ϰͿ ;ͲϰϬȗ& ͬ ͲϰϬȗ ŽƉƟŽŶͿ;ϱͿ ȗ& ͬ ȗ WƌŽƚĞĐƟŽŶ ZĂƟŶŐ ED ϯZ ;/ŶǀĞƌƚĞƌ ǁŝƚŚ ^ĂĨĞƚLJ ^ǁŝƚĐŚͿ ;ϭͿ &Žƌ ŽƚŚĞƌ ƌĞŐŝŽŶĂů ƐĞƫŶŐƐ ƉůĞĂƐĞ ĐŽŶƚĂĐƚ ^ŽůĂƌĚŐĞ ƐƵƉƉŽƌƚ ;ϮͿ ĞƉĞŶĚƐ ŽŶ Ws ĂǀĂŝůĂďŝůŝƚLJ ;ϯͿ ZĞǀĞŶƵĞ ŐƌĂĚĞ ŝŶǀĞƌƚĞƌ WͬE͗ ^dždždždž,Ͳh^ϬϬϬEEϮ ;ϰͿ WŽǁĞƌ ĚĞͲƌĂƟŶŐ ĨƌŽŵ ϱϬȗ ;ϱͿ ͲϰϬ ǀĞƌƐŝŽŶ WͬE͗ ^dždždždž,Ͳh^ϬϬϬEEhϰ Arnold Hom 08/01/17 POWER OPTIMIZER www.solaredge.us h^ രͳ ര 'ZDEz ͳ രര/d>z ͳ രര&ZE ͳ രര:WE ͳ രര,/E ͳ രര/^Z> ͳ രരh^dZ>/ SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 Up to 25% more energy ^ƵƉĞƌŝŽƌ ĞĸĐŝĞŶĐLJ ;ϵϵ͘ϱйͿ DŝƟŐĂƚĞƐ Ăůů ƚLJƉĞƐ ŽĨ ŵŽĚƵůĞ ŵŝƐŵĂƚĐŚ ůŽƐƐĞƐ͕ ĨƌŽŵ ŵĂŶƵĨĂĐƚƵƌŝŶŐ ƚŽůĞƌĂŶĐĞ ƚŽ ƉĂƌƟĂů ƐŚĂĚŝŶŐ &ůĞdžŝďůĞ ƐLJƐƚĞŵ ĚĞƐŝŐŶ ĨŽƌ ŵĂdžŝŵƵŵ ƐƉĂĐĞ ƵƟůŝnjĂƟŽŶ &ĂƐƚ ŝŶƐƚĂůůĂƟŽŶ ǁŝƚŚ Ă ƐŝŶŐůĞ ďŽůƚ EĞdžƚ ŐĞŶĞƌĂƟŽŶ ŵĂŝŶƚĞŶĂŶĐĞ ǁŝƚŚ ŵŽĚƵůĞͲůĞǀĞů ŵŽŶŝƚŽƌŝŶŐ DŽĚƵůĞͲůĞǀĞů ǀŽůƚĂŐĞ ƐŚƵƚĚŽǁŶ ĨŽƌ ŝŶƐƚĂůůĞƌ ĂŶĚ ĮƌĞĮŐŚƚĞƌ ƐĂĨĞƚLJ PV power optimization at the module-level © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2015 V.01. Subject to change without notice. ;ϮͿ /ƚ ŝƐ ŶŽƚ ĂůůŽǁĞĚ ƚŽ ŵŝdž WϰϬϱ ǁŝƚŚ WϯϬϬͬWϰϬϬͬWϲϬϬͬWϳϬϬ ŝŶ ŽŶĞ ƐƚƌŝŶŐ͘ P300 (for 60-cell modules) P320 (for high-power 60-cell modules) P400 (for 72 & 96-cell modules) P405 ;ĨŽƌ ƚŚŝŶ Įůŵ modules) INPUT Rated Input DC Power;ϭͿ ϯϬϬ ϯϮϬ 400 405 W Absolute Maximum Input Voltage ;sŽĐ Ăƚ ůŽǁĞƐƚ ƚĞŵƉĞƌĂƚƵƌĞͿ 48 80 ϭϮϱ sĚĐ DWWd KƉĞƌĂƟŶŐ ZĂŶŐĞ ϴ Ͳ ϰϴ ϴ Ͳ ϴϬ ϭϮ͘ϱ Ͳ ϭϬϱ sĚĐ DĂdžŝŵƵŵ ^ŚŽƌƚ ŝƌĐƵŝƚ ƵƌƌĞŶƚ ;/ƐĐͿ ϭϬ ϭϭ ϭϬ ĚĐ Maximum DC Input Current ϭϮ͘ϱ ϭϯ͘ϳϱ ϭϮ͘ϱ ĚĐ DĂdžŝŵƵŵ ĸĐŝĞŶĐLJ ϵϵ͘ϱ % tĞŝŐŚƚĞĚ ĸĐŝĞŶĐLJ ϵϴ͘ϴ % KǀĞƌǀŽůƚĂŐĞ ĂƚĞŐŽƌLJ II KhdWhd hZ/E' KWZd/KE ΈWKtZ KWd/D/Z KEEd dK KWZd/E' ^K>Z' /EsZdZΉ Maximum Output Current ϭϱ ĚĐ Maximum Output Voltage ϲϬ 85 sĚĐ KhdWhd hZ/E' ^dEz ΈWKtZ KWd/D/Z /^KEEd &ZKD ^K>Z' /EsZdZ KZ ^K>Z' /EsZdZ K&&Ή ^ĂĨĞƚLJ KƵƚƉƵƚ sŽůƚĂŐĞ ƉĞƌ WŽǁĞƌ KƉƟŵŝnjĞƌ ϭ sĚĐ ^dEZ KDW>/E EMC & WĂƌƚϭϱ ůĂƐƐ ͕ /ϲϭϬϬϬͲϲͲϮ͕ /ϲϭϬϬϬͲϲͲϯ ^ĂĨĞƚLJ /ϲϮϭϬϵͲϭ ;ĐůĂƐƐ // ƐĂĨĞƚLJͿ͕ h>ϭϳϰϭ RoHS Yes /E^d>>d/KE ^W/&/d/KE^ Maximum Allowed System Voltage ϭϬϬϬ sĚĐ ŽŵƉĂƟďůĞ ŝŶǀĞƌƚĞƌƐ ůů ^ŽůĂƌĚŐĞ ^ŝŶŐůĞ WŚĂƐĞ ĂŶĚ dŚƌĞĞ WŚĂƐĞ ŝŶǀĞƌƚĞƌƐ ŝŵĞŶƐŝŽŶƐ ;t dž > dž ,Ϳ ϭϮϴ dž ϭϱϮ dž Ϯϳ͘ϱ ͬ ϱ dž ϱ͘ϵϳ dž ϭ͘Ϭϴ ϭϮϴ dž ϭϱϮ dž ϯϱ ͬ ϱ dž ϱ͘ϵϳ dž ϭ͘ϯϳ ϭϮϴ dž ϭϱϮ dž ϰϴ ͬ ϱ dž ϱ͘ϵϳ dž ϭ͘ϴϵ ŵŵ ͬ ŝŶ tĞŝŐŚƚ ;ŝŶĐůƵĚŝŶŐ ĐĂďůĞƐͿ ϳϳϬ ͬ ϭ͘ϳ ϵϯϬ ͬ Ϯ͘Ϭϱ ϵϯϬ ͬ Ϯ͘Ϭϱ Őƌ ͬ ůď /ŶƉƵƚ ŽŶŶĞĐƚŽƌ Dϰ ŽŵƉĂƟďůĞ KƵƚƉƵƚ tŝƌĞ dLJƉĞ ͬ ŽŶŶĞĐƚŽƌ ŽƵďůĞ /ŶƐƵůĂƚĞĚ͖ Dϰ ŽŵƉĂƟďůĞ KƵƚƉƵƚ tŝƌĞ >ĞŶŐƚŚ Ϭ͘ϵϱ ͬ ϯ͘Ϭ ϭ͘Ϯ ͬ ϯ͘ϵ ŵ ͬ Ō KƉĞƌĂƟŶŐ dĞŵƉĞƌĂƚƵƌĞ ZĂŶŐĞ ͲϰϬ Ͳ нϴϱ ͬ ͲϰϬ Ͳ нϭϴϱ ȗ ͬ ȗ& WƌŽƚĞĐƟŽŶ ZĂƟŶŐ /Wϲϴ ͬ EDϲW ZĞůĂƟǀĞ ,ƵŵŝĚŝƚLJ Ϭ Ͳ ϭϬϬ % ;ϭͿ ZĂƚĞĚ ^d ƉŽǁĞƌ ŽĨ ƚŚĞ ŵŽĚƵůĞ͘ DŽĚƵůĞ ŽĨ ƵƉ ƚŽ нϱй ƉŽǁĞƌ ƚŽůĞƌĂŶĐĞ ĂůůŽǁĞĚ͘ SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P400 / P405 Ws ^z^dD ^/'E h^/E'  ^K>Z' /EsZdZ ΈϮΉ ^/E'> W,^ d,Z W,^ ϮϬϴs d,Z W,^ ϰϴϬs DŝŶŝŵƵŵ ^ƚƌŝŶŐ >ĞŶŐƚŚ ;WŽǁĞƌ KƉƟŵŝnjĞƌƐͿ 8 ϭϬ ϭϴ DĂdžŝŵƵŵ ^ƚƌŝŶŐ >ĞŶŐƚŚ ;WŽǁĞƌ KƉƟŵŝnjĞƌƐͿ 25 25 50 Maximum Power per String 5250 ϲϬϬϬ ϭϮϳϱϬ W WĂƌĂůůĞů ^ƚƌŝŶŐƐ ŽĨ ŝīĞƌĞŶƚ >ĞŶŐƚŚƐ Žƌ KƌŝĞŶƚĂƟŽŶƐ Yes Arnold Hom 08/01/17 Arnold Hom 08/01/17 Arnold Hom 08/01/17 Arnold Hom 08/01/17 Arnold Hom 08/01/17 Business Stream ProductsRenewable and Solar Technology TÜV Rheinland PTLPhotovoltaic Testing Laboratory2210 South Roosevelt StreetTempe, Arizona 85282Main Phone: 480-966-1700Main Fax; 775-314-6458Email: info@tuvptl.com TÜV RheinlandNorth America Holding, Inc.1 Federal StreetBoston, MA 02110Main Phone: 617-426-4888Main Fax: 617-426-6888Member ofTÜV Rheinland GroupAttn: John Nagyvary Unirac Inc. 1411 Broadway Blvd Albuquerque, NM 87102 Phone: +505 242 6411Email: john.nagyvary@unirac.com Email:MWitt@us.tuv.comDecember 19, 2014 UL SU 2703 Fire Testing Completed Type of Equipment: PV Mounting System Model Designation: Unirac Roof Mount Test Requirement: UL Subject 2703, Issue 2 TÜV Rheinland File Number:L1-URC140731-RMTÜV Rheinland Project Number:URC14 0731Dear Mr. Nagyvary, This letter is confirmation that the Unirac Roof Mount (RM) PV Mounting System hassuccessfully completed fire testing according to the UL Subject 2703 with references fromUL1703 rev. May 2014 standard.Congratulations on this achievement.The Unirac Roof Mount (RM) PV Mounting System has demonstrated compliance with aClass A Fire Rating when installed with the following Fire Types: • Type 1• Type 2• Type 3Complete test results, including any necessary mitigation measures for the fire rating, canbe found in report R1-URC140731-RM. This correspondence may be used as a Letter of Compliance (LOC) indicating the UniracRoof Mount (RM) PV Mounting System has met the relevant system fire requirements. Sincerely, Mark Witt Engineering Manager TÜV Rheinland PTL, LLC Arnold Hom 08/01/17        5$&.,1* 127 ,1&/8'('  7+,6 ('*( 72:$5'6 522) 5,'*( %$6( 02817 $66(0%/< 62/' 6(3$5$7(/< 4075B%0 ,7(0 12 '(6&5,37,21 47<  &$3 6&5(: 6(55$7(' )/$1*( +(; +($'  ;  81&$ *5$'(  =,1&   3267  2' ;  77 0,//   :$6+(5 6($/,1*  ,' ;  2' (3'0 %21'(' 66   )/$6+,1* 5(3/$&(0(17 7,/( 67,/(  &21( 2 0,//   &2//$5 &2817(5 )/$6+,1*  ,' (3'0  :$6+(5 )(1'(5  ,' ;  2'  66   :$6+(5 63/,7/2&.  ,'  66   &$3 6&5(: +(; +($'  ;  81& $  66   '2 127 6&$/( '5$:,1* 6+((7  2)  5$' 6&$/(  :(,*+75(9 $ 6,=( 7,7/( '$7( '5$:1 %< ',0(16,216 $5( ,1 ,1&+(6 72/(5$1&(6 )5$&7,21$/  7:2 3/$&( '(&,0$/  7+5(( 3/$&( '(&,0$/  35235,(7$5< $1' &21),'(17,$/ 7+( ,1)250$7,21 &217$,1(' ,1 7+,6 '5$:,1* ,6 7+( 62/( 3523(57< 2) 48,&. 02817 39 $1< 5(352'8&7,21 ,1 3$57 25 $6 $ :+2/( :,7+ 287 7+( :5,77(1 3(50,66,21 2) 48,&. 02817 39 ,6 352+,%,7(' &23<5,*+7 ‹  48,&. 02817 39      81/(66 27+(5:,6( 63(&,),('  40756 7,/( 5(3/$&(0(17 67,/(  3267  Arnold Hom 08/01/17 GET OFF THE ROOF FASTER THAN EVER BEFORE SMSOLAR MOUNT SOLARMOUNT defined the standard in solar racking. New enhancements are designed to get installers off the roof faster than ever before. Components are pre-assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. OPTIMIZED COMPONENTS • VERSATILITY • AVAILABILITY • DESIGN TOOLS ROOF MOUNT SYSTEMS NEW ENHANCEMENTS ELIMINATE THE GROUNDWIRE FROM YOUR SOLARMOUNT ARRAY LOSE THE COPPER & LUGS INTEGRATED GROUNDINGPOWERED BY: UL2703 BONDING & GROUNDING SYSTEM FIRE CLASSIFICATION CLASS A - TYPE 1, 2, 3 & 10 MODULES MECHANICAL LOADING LISTED UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN OPTIMIZED COMPONENTS INTEGRATED BONDING & PRE-ASSEMBLED PARTS Components are pre-assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps or bonding jumpers to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS 4XLFNO\ VHW PRGXOHV ˊXVK WR WKH URRI RU DW D GHVLUHG WLOW DQJOH &KDQJH PRGXOH orientation to portrait or landscape while securing a large variety of framed PRGXOHV RQ ˊDW ORZ VORSHG RU VWHHS SLWFKHG URRIV $YDLODEOH LQ PLOO FOHDU DQG GDUN DQRGL]HG ˉQLVKHV WR RXWSHUIRUP \RXU SURMHFWV ˉQDQFLDO DQG DHVWKHWLF DVSLUDWLRQV AVAILABILITY NATIONWIDE NETWORK Unirac maintains the largest network of stocking distributors for our racking VROXWLRQV 2XU SDUWQHUV KDYH GLVWLQJXLVKHG WKHLU OHYHO RI FXVWRPHU VXSSRUW DYDLODELOLW\ DQG RYHUDOO YDOXH WKHUHE\ SURYLGLQJ WKH KLJKHVW OHYHO RI VHUYLFH WR users of Unirac products. Count on our partners for fast and accurate delivery to meet your project objectives. Visit Unirac.com for a list of distributors. AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE &UHDWLQJ D ELOO RI PDWHULDOV LV MXVW D IHZ FOLFNV DZD\ ZLWK 8%XLOGHU D powerful online tool that streamlines the process of designing a code FRPSOLDQW VRODU PRXQWLQJ V\VWHP 6DYH WLPH E\ FUHDWLQJ D XVHU SURˉOH DQG recall preferences and projects automatically when you log in. You will enjoy the ability to share projects with customers; there’s no need to print UHVXOWV DQG VHQG WR D GLVWULEXWRU MXVW FOLFN DQG VKDUH SMSOLAR MOUNT BANKABLE WARRANTY $V D +LOWL *URXS &RPSDQ\ 8QLUDF KDV WKH ˉQDQFLDO strength to back our products and reduce your risk. +DYH SHDFH RI PLQG NQRZLQJ \RX DUH UHFHLYLQJ SURGXFWV RI H[FHSWLRQDO TXDOLW\ 62/$502817 is covered by a 10-year limited product ZDUUDQW\ DQG D \HDU OLPLWHG ˉQLVK ZDUUDQW\ TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues LQ UHDO WLPH $Q RQOLQH OLEUDU\ RI GRFXPHQWV LQFOXGLQJ HQJLQHHULQJ UHSRUWV VWDPSHG OHWWHUV DQG WHFKQLFDO GDWD VKHHWV JUHDWO\ VLPSOLˉHV your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO FHUWLˉFDWLRQV IRU   DQG 2+6$6  ZKLFK PHDQV ZH GHOLYHU WKH KLJKHVW VWDQGDUGV IRU ˉW IRUP DQG IXQFWLRQ 7KHVH FHUWLˉFDWLRQV GHPRQVWUDWH RXU H[FHOOHQFH DQG FRPPLWPHQW WR ˉUVW FODVV EXVLQHVV SUDFWLFHV INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MICROINVERTER MOUNT w/ WIRE MANAGEMENT INTEGRATED BONDING L-FOOT w/ T-BOLT NEW ENHANCEMENTS R © PUB - 150101 - DIGITAL UPDATES Arnold Hom 08/01/17 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration(Single Phase Inverters)This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapidshutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014690.12 (1) through (4).Kit Contentsƒ Rapid shutdown cablesƒ Micro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keepthem for installation of other rapid shutdown kits)Cable InstallationPerform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to theSafety Switch in the SolarEdge Installation Guide].1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCDindicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step.2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING!If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the inputcapacitors of the inverter to discharge.3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover.4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals,as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals.Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase7.6-11.4 kW inverters.DC connection terminalsDisconnect hereDisconnect hereSwitch terminal blockArnold Hom 08/01/17 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters)Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch,making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going intothe DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in):ƒ If the cables at the top are red and black from left to right, connect as shown below.Figure 2: Rapid shutdown cable connected – option 1ƒ If the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 26 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connectionspring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable fromthe switch to the DC+ terminal block.7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality.8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m.Red (+) Black (-)Black (-) DC+ DC-Red (+) with rapidshutdown resistorBlack (-) Red (+)Black (-)Red (+) with rapid shutdown resistorDC+ DC-Arnold Hom 08/01/17 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters)Rapid Shutdown Kit Installation - MAN-01-00186-1.6 3 Inverter Software Compatibility Check and UpgradePerform this procedure after activating the inverter [Step 1 in Chapter 5: Commissioning the Installation of the SolarEdgeInstallation Guide], and before pairing (Step 2 in Chapter 5 of the SolarEdge Installation Guide).To use the rapid shutdown feature, the inverter communication board firmware (CPU) must be:x Version 2.0700 or higher, if the CPU version is 2.0xxxx Version 3.0700 or higher, if the CPU version is 3.0xxx► To check the inverter CPU version:1 Verify that the inverter has been activated using the activation card supplied with the inverter.2 Press the LCD light button short presses until the screen below is reached.ID: ######## ## DSP1 /2:x.xxxx/x.xxxx CPU :0002. 0 700 Country:XXXXX 3 Check the CPU version number. If lower than 2.0700, upgrade the inverter software as described below; otherwise proceedto “Power Optimizer Pairing”.► To upgrade the inverter software:Use the supplied SD card adapter or the micro-SD card, which can be removed from the adapter, according to the activationcard slot on your inverter communication board, labeled .1 Verity that the AC breaker connected to the inverter is OFF.2 Open the inverter cover’s six Allen screws and carefully pull the cover horizontally before lowering it, as described in itsmanual.3 Insert the card into the card slot on the communication board. If the communication board has an SD card slot, use thesupplied SD card adapter. If there is a micro-SD card slot, remove the micro-SD card from the adaptor and insert it.4 Close the inverter cover and turn the AC on. If upgrade is required (as described above), it starts automatically.5 Wait for the message "Done" to be displayed on the LCD.6 Verify the correct version as described above.7 Remove the card from the inverter and keep it for additional kit installations.Power Optimizer PairingPairing at this stage will reprogram the power optimizers to perform rapid shutdown.1 Verify that the ON/OFF switch at the bottom of the inverter is OFF.2 Turn ON the AC breaker and the Safety Switch.3 Perform Pairing as described in Step 2: Pairing, of Chapter 5: Commissioning of the SolarEdge Installation Guide. Enabling Rapid ShutdownThere is an option in setup mode to enable the functionality of rapid shutdown.1 Verify that the ON/OFF switch at the bottom of the inverter is ON.2 Enter Setup mode by pressing and holding the LCD light button.3 Select Maintenance Î Optimizer Conf. Î Set Rapid Shutdown. NOTE:Whenever replacing, removing or adding a component in the string, perform Pairing and rapid shutdown setting.TroubleshootingIf the inverter does not enter production mode and the LCD displays Night Mode, the connection order of the rapid shutdowncables may be incorrect. Recheck the cables and make sure that the rapid shutdown cables connected to the bottom of theswitch are reversed relative to the cables connected at the top of the switch (see Figure 2 and Figure 3).Arnold Hom 08/01/17