Loading...
B-2017-0010M CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO: B-2017-0010 10088 WOLFE RD STE 100 CUPERTINO, CA 95014 (316 20 108) M R CHRISTENSEN CONSTRUCTION INC CONCORD, CA 94520 OWNER'S NAME: CUPERTINO PROPERTY DEVEL I LLC DATE ISSUED: 06/13/2017 OWNER'S PHONE: 408-343-1088 PHONE NO: (925) 674-0464 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class B Lic. #Z4 262 Contractor M R CHRISTENSEN CONSTRUCTION INC Date 06/30/2019 X BLDG —ELECT _PLUMB MECH RESIDENTIAL X COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing _ with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. JOB DESCRIPTION: STE 100 STOUTS - T.I. - RESTAURANT (3,362 SF) I hereby affirm under penalty of perjury one of the following two declarations: 1. 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Irfor ce of the work for which this permit is issued. . I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this Sq. Ft Floor Area: Valuation:,$525000.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read,this application and state that the above APN Number: Occupancy Type: information is correct. I agree to comply with all city and county ordinances 31620 108 A (Tenant Improvements) and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree,to save indemnify and keep harmless the City;of Cupertino against liabilities, judgments, costs,' and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. ignature /Z��..Date 8/14/2017 Issued by: AbbyAyende OWNER DECLARATION Date: 06/13/2017 -BUILDER I hereby affirm that I am exempt from the Contractor's License Law for one of the RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is following two reasons: r. I, as owner of the property, or my employees with wages as their sole installed without first obtaining an inspection, I agree to remove all new materials for compensation, will do the work, and the structure is not intended or offered for inspection. sale (Sec.7044, Business & Professions Code) 2. I, as owner of the property, am exclusively contracting with licensed Signature of Applicant: contractors to construct the project (Sec.7044, Business & Professions Code). Date: 8/14/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER r. I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance, as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code, for the performance of the work for which this California Health & Safety Code, Sections 25505, 25533, and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health &Safety Code, Section 25532(a) should I store or handle hazardous 3. 1 certify that in the performance of the work for which this permit is issued, I material. Additionally, should I use equipment or devices which emit hazardous shall not employ any'person in any manner so as to become subject to the air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If, after making this certificate of will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and exemption, I become.subject to the Worker's Compensation provisions of the the Health & Safety Code„ Sections 25505, 25533, and 25534. Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. O00 wner or authorized agent: APPLICANT CERTIFICATION Date: 8/14/2017 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct. I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction, and hereby authorize representatives of this city of work's for which this permit is issued (Sec. 3097, Civ C.) to enter upon the above mentioned property for inspection purposes. (We) agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code, Section 9.18. 1 understand my plans shall be used as public records. Licensed Signature Date 811412017 professional CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 UPE1371iV0 (408) 777-3228 - FAX (408) 777-3333 -- bUildiinntc rc cuperlino.ora 6-2-01 '�—p0/ 0 r l *rr�cr i+nwre rntrna rn�i n nrtt rrnrs ei TrttA7lnAt l P% 1 1 TiTzvICiohy i n-Pri:RRF.r) ownINAL PERMIT iE PRG1SCrADDKESS 10088 Wolfe Road Suite 100 AIIN$ 1 `_ •- �� ... I W OWNERNAME Susan Song PHONE/ (408)343-1088x110 E-h9All, ssong@kcrdevelopment-.com Stevens Creek Blvd,#200 Cn�Y,STATE,z1F Cupertino, CA 95014 PAx (408) 863-7333 CON'I'ACI'NAh1E Sunnie Wu PHONE (510)488-6476 11 -MAIL sunniew restaurantdesi nconce ts.co l3TREl?1'All1)RtaSS 1017 22nd Ave Suite 110-b cITY,srATE 2tr Oakland, CA 94606 Mx(510) 436-7400 13 OWNER ❑ OWNP.R•AUHMER ❑ OWMRAOENT 11 CONIRACI'01t 13 Co1rRACTORAGLNr �' ARCHITECT D ENomser, ❑ DEVELOPOIt LZ TENANT CONTRACTOR NAME G_GS LICENSE DER o Z LICrNSE TYPE AUS. LiC ft CUV1P YN h1E !F+� J (moo, '/y( cre E�h�AIL AX rj�f� GUH SIRL'L•'F AUDRE'S V(Sd t7� � o CETY, C, �� C/ ZU Plt()NE. ARCIRTECIYGNOINEERNAMR Peter Braun 1,10ENSENu"IDER C-13221 BUS, LIC I COINVANYNAME Restaurant: Design Concepts ?-MAfI. 11 I.1 O@res tater antdes i.gnconcepts . co Pax (510)436-7400 STREF.TADORMS 1017 22nd Ave Suite 110-b G'1TY,STATG,ztP Oakland, CA 94606 PHONE (510)436-93 32 DESCRIPTIO, OF WORK NON e'4 ment, new hood, new millwork, new Walls, new restrooms, and new dining room finishes. No patio work w/this permit. EXISTING USE N/A PROI' SW USG WNS7R.TYPr A-2 1-A aSTORIP.S 5 USE TYPE OCC. SQ.r•C VALUATION {S) ExlsrG ARrA3362sgfi NEW FLOOR ..As'+^ n/a Drwo AREA n/a TUML 3362sgft MARr:A A-2 1-A 17.3 3362 525,000 BATHROOM 344s ft[e1Tt`HEN REMODCLAREA j, 710sgft ,IMMODELAREA OITIER [U]NIODELALUM 2308sgft PORCH AMIA DECK" R&\ TOTAL )ECIUPOKCH AM GARAGE AREA: n/a n n/a 8DETACH n/a ATTACII I fl AIVRLI.ING UNITS: ; IS A SECOND UNrr J1YLS SECOND STORY f] YES n/a BEING ADDED? ONO ADD111ON? ®NO PRE :5 LICArI6'q E[YE. IF Yes, PROVIDE COPY OF [STHE DLDG AN [3 YES 'R TOTAL VALUATION: _ I'LANNINGAPPI.B []NO, PLANNINOAPPROVAL LBITHR EICIiLER11ONR? ®NO 525,000 BY my signature below" 'ccrti ry to cacti of the following: i am the pinperty owner or authorized agont to act on the property owner's behalf.I have read this application and the inreririlttion {Rave provided 1s correct I have read the Description or Work and verity it is accurate, 1 agree to comply with atl applicable local ordinances and state laws'iohiting to builldding coltstrtt(;tigalL I authorize representatives of Culwrtino to enter the above•idenliricd property for inspection purposes, Signature o rAppl icant/Agert,t; Date: 1/3/2017 3UPPLEI-MENTAL, INFORMATION REQUIRPI) PJ AN C)tECK TYPE ROUTING SLIP . 0 0V R'rIIE•COUN'rER ❑ BUILDING PLAN REVIEW —New SFD or Multifirinily, dwellings. Apply Por demolition permit for existing building(s). Demolition permit is required prior to issuance orbuilding permit for now building. ❑ EXPRESS ❑ PLANNINO' PLAN RLVIELY . Commercial Bldgs: 11rovide a completer! Hazardous Materials Disclosure; 1:1STANDARD 0 'PUAt'Ic WORKS Tor—in if any FIamrdous,Materials are being used its part orthis project. ❑ LARCE ❑ PIRR' DEPT x Copy of planning AoproJal Letter or Mcoting with. Planning prior to 0 DL\roR ❑ sANrrARYsrwFRwsTRiar submittal of Building Permit application. y 1.1 ENVIRONT4ENTALREALTIi Bldgflpp_201 Ldoc revised 0612!!11 Ihttp:9www.maxitrol.com/ES/index es.htmll � ._ D Espanol a t ® I.. { M , ' I (index en.htmll Home About Us' 1 Distributors Products Regulator Sizing Contact Search Conversions I ! s ml) (regsizprog.asp) (contact.html) (.ublicsearch.as') (conversions.htnil) 9 Nt elitin tame .i{i � ANT I t www.ITIERTIK111- TROL.com d Attention: [00 O Mh kkh)` I A vent limiting orifice or device when used with Maxitrol regulators,does not release or relieve fuel gas into the environment during normal operation. l ' it 1 Maximum Allowable. I" Vent Limiter ,; Specific Flow Rate,cubic feet v Gravity1per hour(cm , , 3/s) , Vent limiter for use only with natural, tt _ manufactured, mixed gases and LP 0.64 2.5 (19.5) : 9`: gas-air mixtures. i:''„ .' Vent limiter for use with liquefied 1.53 1.0 (7.9) 7 EL r'' petroleum gases. i — miwoozmiliAN, Komb.N.N. we r. -'” , l Ball Cher&: kki 1 ,„'',, S' \ 1 bI_ _ , 1-1 - -- ,et 12A39 Open/Normal Closed/Limiting PositionPosition „i , m - i ;,� t,. 1 r. 12A09 (1/8" NPT) 12A39(3/8" NPT) 12A49 (11J2n NPT) Yi, . NOTES: , Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure Is critical.Vent limiters should not be used outdoors if they are exposed to the environment. ,. 13A15,13A15-5,and 13A25 Vent Protectors are available for outdoor applications to ensure proper vent protection. Vent limiters can only be installed in regulators for which they are certified.Vent limtiers must only be installed directly into the vent connection of the regulator without intermediate pipe or fittings.When using a vent limiting deivice,the regulator must be installed in a horizontial upright position. 4'. i NOTE:Maxitrol vent limiters meet ANSI Z21.80/C5A 6.66.The requirement states"Vent limiters shall be of materials having melting points of not less than 800°F(427°C):' Home(index en.htmil I Events(uacomingevents.htmll I Careers(iobs.html)I Contact(contacthtmil I Literature Request(iitreouests.asn) Ihtgr4 I. a,/ES-nd es mul — Es pacloC ' 111 i-1 (', O(index en.hfml) Home About Us „ Distributors Products Regulator Sizing Contact Search Conversions A eiIt �hmeni �DE 'roducts.html)• (regsizprog.asp) (contacthtml) " I (•ublicsearch.as.) (conversions.html)i 1 I! www.mERTIK 1311•XITROL coo mi, NEPA 54/ANSI Z223.1 NATIONAL FUEL GAS CODE(2012) 5.8.6 Venting. . 5.8.5.1.Line Gas.Pressure'Regulators. 065-5 J_L._. , Line gas pressure regulators shall comply with the following I /'~ %, ` ' 1.An independent vent to the exterior of the building,sized in accordance with the regulator manufacturer's instructions,shall be provided where the location of the regulator is such that a ruptured diaphragm will cause a hazard. 0 , a.Where there is more than one regulator at a location;each regulator shall have a separate vent to the outdoors,or if approved by 1 the authority having jurisdiction,the vent lines shall be permitted to be manifolded in accordance with accepted engineering practices to minimize backpressure in the event of diaphragm failure.(See 5.9.7 for information on properly locating the vent.) ` b.Materials for vent piping shall be in accordance with section 5.6. Exception:A regulator and vent limiting means combination listed as complying with ANSI 221.80/CSA 6.22,Line Pressure Regulators,shall be 1 permitted to be used without a vent to the outdoors. 2.The vent shall be designed to prevent the entry of water,insects,or other foreign materials that could cause blockage. '' 3.The regulator vent shall terminate at least 3 ft(0.9 m)from a source of ignition. 4.At location where regulators might be submerged during floods,a special antiflood-type breather vent fitting shall be installed,or the ;- vent line shall be extended above the height of the expected flood waters. i 5.A regulator shall not be vented to the appliance flue or exhaust system. , ,a ( Codes for Vent Limiters ' l Vent limiters are designed for use indoors and spaces where limiting the amount of gas escapement due to diaphragm failure is critical.Vent limiters i should not be used outdoors if they are exposed to the environment. , Regulators used outdoors must be installed in accordance with one of the following national codes: !,. 1 A.'National Fuel Gas Code; ANSI Z223.1 / NFPA 54 2012 section "9.1.19 Venting of Gas Appliance Pressure Regulators. Venting of gas appliance pressure regulators shall comply with the following requirements:(2)Vent limiting means shall be employed on listed appliance regulators only.(3)In the case of vents leading outdoors,Means shall be employed to prevent water from entering this pipe and also to prevent blockage N of vents by insects and foreign matter:' n B.International Fuel Code 2011 section "410.3 Venting of Regulators. i Pressure regulators that require a vent shall have an independent vent to the outdoors The vent shall be designed to prevent the entry of water or i' foreign objects.EXCeption:A vent to the outdoors is not required for regulators equipped with and labeled for utilization with approved vent-limiting devices installed in accordance with the manufacturers instructions." 1 C.,Uniform Plumbing Code IAPMO/ANSI UPCI-2012 section "1209.7.5 Venting. 1209.7.5.1 Line Gas Pressure i'' Regulators. r Lihe gas pressure regulators shall be installed In accordance with the following requirements: S =i " (1)An independent vent to the exterior of the building,sized in accordance with manufacturer's instructions,shall be provided where the location of a 1'4 regulator is such that a ruptured diaphragm will cause a hazard.Where more than one regulator at a location,each regulator shall have a separate vent i 't to the oudoors,or where approved by the.Authority Having Jurisdiction,the vent lines shall be permitted to be manifolded in accordance with accepted j engineering practices to minimize backpressure in the event of diaphragm failure.[See NFPA 54:5.9.7]for information of properly locating the vent) Materials for vent pipes shall be in accordance with Section 1209.5. 1 :r gii li Z.agOatorth .n'' btiliordtin.' -at c.m e m; sn its rl, ccordaiir rw xh ANSlf 9 8'O�ICS/t:6shallabet rmitte'd tos ,ose tfao,' E vein:ze(t ` .o. ..if ' (2)The vent shall be designed to prevent the entry of water,insects,or other foreign materials that could cause blockage' ,, Vent limiters will not prevent water,insects,or other foreign materials from entering the regulator. s' '1 i : i' ,'' CAIN CSA B149.1 Natural Gas&Propane Gas Installation Code Canada(2011) ;` 5.2:2 Additional requirements for pressure regulators for propane applications 1, I ! G<i 5.2.2.4.When used on a system operating at 2 psig(14 kPa)or less,a line pressure regulator equipped with a leak limiting sgstem orificed for 1 ff/h • (r, 4'; (0.0283 m'/h)of having aspecific gravity if 1.53 shall be exempt from the requirement of Clause 5.2.1.5(b). 1 A regulator with vent limiting means shall be installed in a ventilated space only. ( • dditional requirements for pressure regulators for natural gas applications .1.When used on a system operating at 2 psig(14 kPa)or less,a line pressure regulator equipped with a leak limiting system orificed for 2.5 ft'/h ( 6 m'/h)of a specific gravity of 0.6 shall be exempt from the requirement of Clause 5.2.1.5(b). A i ulator with vent limiting means shall be Installed in a ventilated space only. 5.2.3.2.For systems with inlet pressures above 2 psig(14 kPa)a pressure regulator shall be exempt from compliance with Clause 5.2.1.5(b)of this j Code,provided that it is equipped to limit the escape of gas from the vent openings,even in the event of a main diaphragm failure,to less than 2.5 ft'/h J (0.0706 m'/h),that it has having an overpressure protection device(OPD)set to a pressure either below 2 psig(14 kPa)or 2 times the delivery pressure 1 on the system and certified,to ANSI Z21.80/CSA 6.22. I ' I • i' Home(index en.htmll I Events(upcomineevents.htmll I Careers(iobs.htmll I Contact(contact html)I Literature Request(litreouests.asol ®2017 Maxitrol Company,All Rights Reserved t7111111115S1 lia Since 1970 Certifies that: , Adrian E® .ovoa Completed a Training Course in the Theory and Practice of. Applying Subsurface Interface Radar in Engineering and Geophysical Investigations. _ _ _ _ StructureScan Mini- . November 13, 2013 f NC 'k _ e"---Vic_.‘„ZZZ._-- -7 - Christopher Hawekotte, President Dan Welch,Training Manager Geophysical Survey Systems Inc. x -• - pjstrt !Wa ,Salem;NH :03079gUSAt' s, _ -.- - - =w p 31109 AX 8 954 _ Z lrrd 'a _ : ,-,,,,,„„-,71,--25!4--.;-4.-,,,,„4,. 3 �u 3:89 �`F r; _,.._> -,. an _ - = �,.,,. .-. _ ww geo-7,3,-k'',7,-":",7‘,',..14%,t4';''hsiO - -, :_.=�' .-'i'��f -y .�.rr - -..� �,., ., �.,<; .'�' _"may r ,:' '''41.41.,,,...W .� °2�. '�.;; .. .,. , fir. 3:. �m r- ;,, � •. :ktn,:�M rr �' - a� ,..,,,,4A•44.4- u • .1ur ,: .�,.. ,w 3 " r,L„.‘,44' ,rc aa„..w, `Y a ,-,,,'A-,4,, 1*' iy+, „..6 - -.:_..tr.. - : .,tf b xt ... ';k: ,. -m ,,, A,, ; y ,.., � ' h -,- "x: Y• 4>E 4. _.,,, .R ,, 4 , 4 r,., 2� t .T. - :%'.,,,!-', i� r 6 .: ' l+-`- „, _:,, ;.. yy.'e; ",.a-,. ,.. ., ,NF 1. . ..r,4.0:',":'�'• e��i : . �”' �;, 6 k`; _ a _< .F`"�r_ ?� jta-r: eY'}w•, ,..;+. '<,' N',i,., 1;71,‘1 .-_.:'S '"_ ,� vi+^ ''a jl`+a,s,� f.$� ,� - ". .�i". w"R"-el � €>`}s .--. Y"'a s' B -a-o ,7OO( L) EL (-` fr Service Agreement No.:21400 Date: 09/29/2017 3801 Charter Park Court,Ste.M,San Jose,CA 95136 Tel:(408)266-7000 Fax:(408)266-7050 p Reg ❑ Night ❑ Sat ❑Sun ❑ PW Contactus@safe2core.com Contractor License No.:940453 CUSTOMER'INFORMATION: JOBSITE INFORMATION: Company: MR Christensen Project Name: Stout Burgers Requestor: Matt Christensen Job/Project#: Cell II: P.O.#: 925.766,3713 ' Tel#: Addre 10088 Wolfe Rd,Cupertino , Address: • Contact: Ranolfo Remarks: Tel#: 209.409.1630 DESCRIPTION'OF SERVICES: I CONCRETE SCANNING 0 CONCRETE CUTTING `: 0 UTILITY LOCATING 0 OTHER, Instructions&Special Equipment: Scan 4-6 areas 1'x 2'on 12"thick slab and(3)8'x 16'ceiling.Lift on site. Completion Notes: -Scanned3areas on slab Marked all rebar and conduits found in slab Grit open areas only All • Work completed,will comeback next week for overhead scanning Operator: Adrian Start Time: 01:30 PM(' Lunch Break: End lime: 02:15 PM(• Total Hours: 0.75 Oper/Helper: Start Time: Lunch Break: End Time: Total Hours: Disclaimer:Ground Penetrating Radar(GPR)is a non-destructive method used to locate embedded materials in concrete and soil such as plastic,metal,steel,voids etc.Safe2core, Inc.will not be liable for any damages to rebar,post-tension cables,conduits,or any other embedded targets that arise as a result of Ground Penetrating Radar inspections performed by our technicians. GPR has accuracy limitations that could result in human error. Safe2core,Inc.will not be liable for any damages to nonconductive lines(Nonmetallic,PVC,Water, Etc.)and for any conductive lines(Electrical,Gas,Etc.)with no accessible connection point or those that do not appear on blueprints,maps,or as-builts provided by customer prior to locating.Safe2core will not accept back charges under any circumstances for the repair of any damaged embedded target.Safe2core reserves the right to,choose the repairing company if we believe Safe2core.is responsible for it.Safe2core,Inc.will not be responsible for any loss or damage arising out of the use of,or reliance on the data collected,or the report presented. Customer further agrees that he/she has carefully read the forgoing release agreement,knows and understands the contents of the same,and signs this release agreement as his/her own free act.Customer shall indemnify and hold Safe2core,Inc.and its directors,officers,employees,and agents harmless from and against any liability and all claims,actions,proceedings,damages,losses and expenses(including attorneys'fees)arising from any personal injury or death,and for injury or destruction of property of a person' or organization,including any loss that arise from the performance of the work under this agreement. Ranolfo a Accepted By(Print Name) (Signature)