Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13120173
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20771 MCCLELLAN RD CONTRACTOR:R&B CONTRACTING PERMIT NO: 13120173 OWNER'S NAME: ALEXANDER&YE YINING MARTINOVIC 5655 SILVERCREEK VLY RD DATE ISSUED:05/02/2014 OWNER'S PHONE: 4083400164 SAN JOSE,CA 95138 PHONE NO:(408)410-7100 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL 1" �p / ADD 820 S.F.TO FRONT OF SFD. REMODEL 200 S.F.OF License Class Lic.# Z G► Y INTERIOR, ADD 2 SKYLIGHTS &2 SUN TUNNELS �/f Contractor �`" g Date 2 l I hereby affirm that I am licensed under t e provisions dChIpter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I dwill maintain a certificate of consent to self-insure for Worker's Compe sation,as provided for by Section 3700 of the Labor Code,for the perfo anteof the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$200000 a and will maintain Worker's Compensation Insurance,as provided for by S ti n 3700 of the Labor Code,for the performance of the work for which this APN Number:35916012.00 Occupancy Type: it is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. t agree to comply with all city and county ordinances and state laws relating WITHIN 180 DA IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 D + OM ALLED INSPECTION. indemnify and keep harmless the City of Cu ertino against liabilities,judgments, C/ costs,and expenses which may accrue tns s ity in consequence of > y / granting of this permit. Additionally hei9Cq) icunderstands and Date: with all non-point sou e regulatiolis per utino Municipal e,Section 9.18. RE-ROOFS: Signature Date 2 �`f Alt roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for L—"- inspection. ElOWN -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: The following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District t performance of the work for which this permit is issued. will maintain compliance with the Cu er.0rnicipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Section 5,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this / Owner or authorized agent: ate: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,[ CONSTRU TION L DING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,1 must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shalt be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that t have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state taws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION 112 COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION n -V 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 ^_� V CUPERTINO (408) 777-3228• FAX (408)777-3333•building(Wcupertino.org \ ❑NEW CONSTRUCTION © ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS APN# ZUq-41 MCCLF-(-LAt j fZO,. C.UPEIZ-It tO , CA°ISOs 3�jr1 - I C)I -2. OWNER NAME PHONE E-MAIL ALEXAIvbEfZ MA2TIrvOViC p3 - 3 0 - C�16 " ALEXAN,`3EIZ,MAI Tli\jo'-,K:(C:'G-MAIL-C STREET ADDRESS . CITY, STATE,ZIP FAX Z04�1 MCCLEL-LAN W CUPG1ZTI►1J0 , CA c�5014 CONTACT NAME APHONE E-MAIL (_�XAN�EP. M�2�r 11VO� I C 03 - 3 0 - 01614, ALEXA,\JCM,N1APTI1\)0VICC' GMAIL.a M STREET ADDRESS CITY,STATE, ZIP FAX 2-64771 MCCLELLAIJ RD C,UPIE>zrr t10 , CA C15014 - OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# NADIA PiC' iC0 COMPANY NAME E-MAIL FAX 13C,,c-T DESIGN 1S,,UP1C> Bcc-T S, u0io C YANGO . M STREET ADDRESS CITY,STATE,ZIP PHONE '5$G t-,3 . 1ST ST/LcE"r 4226 SAN J-05 CA (_)46 - Zl 5 DESCRIPTION OF WORK 2>3ZO s. 4 Od a;+16 in in on n+e.r or �i oi mc,54eroo,,,% C'A J Z Skt� 1"' Z- su•,-i-vnne�s EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES i� USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA 5 1 AREA Z AREA NET AREA G 7 BATHROOM KITCHEN L OTHER D C/`"'0 REMODEL AREA REMODEL AREA REMODEL AREA 'L PORCH,AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: EIDETACH ❑ATTACH x DWELLING UNITS. ISA SECOND UNIT []YES SECOND STORY ❑YES BEINGADDED? ®NO ADDITION? ONO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RE TOTAL VALUATION: PLANNING APPL# ENO PLANNING APPROVAL LETTER EICHLER HOME? ®NO r' 'j 00 ! 000 By my signature below,l certify to each of the following: I am the property owner or authe "ent to e(on th perty owner's behalf I have read this application and the information I have provided is correct. I have read the Description of Work and veri ccurate. 1 agree to comply with all applicable local ordinances and state laws relating to building construction. 1 authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date. 12 12-0 /'Z01-j SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP _New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure TANDARD El PUBLICWORKS form if any Hazardous Materials are being used as part of this project. LARGE ❑ FIRE DEPT _Copy of Planning Approval Letter or Meeting with Planning prior to 11 vtA•IOR El snxrrARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: 20771 MCCLELLAN RD DATE: 12/20/201371REVIEWED BY: MELISSA APN: 359 16 012 BP#: `VALUATION: 1$200,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex 72nd Unit? 0 Yes No PENTAMATION 1R3SFDADD USE: OTC. 0 Yes 0 No PERMIT TYPE: WORK ADD 820 S.F. TO FRONT OF SFD. REMODEL 200 S.F. OF INTERIOR ADD 2 SKYLIGHTS & 2 SUN SCOPE ITUNNELS OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. s.f. R-3 (Custom) II-B,III-B,IV,V-B 820 $2,577.00 IR3PLNCK $1,617.00 IR3INSP TOTALS: 820 $2,577.00 $1,617.00 MECII, HOURLY () Yes O No PLUMB,HOURLY Q Yes Q No ELEC,HOURLY 0 Yes E)No 14t-clr. Plun t-'hexh 'Irunh. Pluo(Cfrcr'- Ekz. flan C.hccI Much. Perwit Fec Plrrrnb. Permit;. r: flee. Permit Fee: Other Mech.Insp. (Other Plumb Irish. Other Elec.Insp. Lj Ifech. Imp.Fe. Phan]). hrsp. Tee Elec.Insp. Fee: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'1 info. FEE ITEMS (Fee Resolution 11-053 Ef. 711113) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,577.00 200 s.f. Remodel,Other Suppl. PC Fee: 0 Reg. 0 OT F0,07 hrs $0.00 $418.00 IREMRESOTH PME Plan Check: $0.00 F-2-7 # Skylight Permit Fee: $1,617.00 $836.00 1SKYL<10SF <= 10 s.f. Suppl. Insp. Fee:Q Reg. 0 OT TO.0 Thrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Consit-uction Ttzr: Administrative Fee., 0 Work Without Permit? Yes (E) No $0.00 0 Advanced Planning Fee: IPLLONGR $114.80 Select a Non-Residential 0 Travel bocurnentution Fees: Building or Structure 0 i Strong Motion Fee: IRSEISMICR $20.00 Select an Administrative Item Bldg;Stds Commission Fee: IBCBSC $8.00 SUBTOTALS: $4,336.801$1,254.00 TOTAL FEE: F $5,590.80 Revised: 10/01/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RT I'NO Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: Z-,;r PERMIT# OWNER'S NAME: ` ICS PHONE# 410'5 3 Y O — '016Y GENERAL CONTRACTOR: (�c,v Ae—1 1„/6 BUSINESS LICENSE# ADDRESS: # 3 51 -/W CITY/ZIPCODE: 5'6ty *Our municipal code requires all business s working i the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: &Vi! ti-c7 V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum/Wood Glass/ Glazing Heating Insulation Landscaping Lathing Masonry Painting /Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Contractor'Signature Date 2010 CALGREEN RESIDENTIAL CHECKLIST — .MANDATORY ITEMS .COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION. CUPERTINO ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL .10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228 • FAX(408)777-3333• building(5)cupertino.orgSUBMITTA PURPOSE: -L # 1 The 2010 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory-built housing and other types of swellings with sleeping accommodations and new acce's"sory buildings associated with such uses. Existing site and landscaping improvements that are not otherw' e not subject to the requirements of CALGreen. OPY, Project Name: . Martinovic addition EC Project Address: 20771 McClellan Rd., Cupertino, CA Project Description: 820 Sq.ft. front addition 20?013 Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the 2010 California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Requirements A4.1 PLANNING AND DESIGN Planning and Design - Site Preservation 4.104.1 A site plan and inventory of the site is developed and used to minimize site disturbance in order preserve desirable existing natural resources and ❑X minimize future adverse effects on the proposed structure. Planning and Design - Site Development 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. MX 4.106.3 The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage X❑ system will manage all surface water flows. Page I of 5 CalGreen 2010.doc revised 08/27/11 A4.2 ENERGY EFFICIENCY General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum ❑ ❑ standard design required by the California Energy Standards. . . .3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the follow methods. ❑ Water saving fixtures or flow restrictors shall be used per Table 4.303.2. ❑ ❑ As of 7/01/2011 ❑ A 20 percent reduction in baseline water use shall be demonstrated per Table 4.303.1. 4.303.2 When using the calculation method specified in Section 4.303.1, 0 multiple showerheads shall not exceed maximum flow rates. ❑ As of 7/01/2011 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with specified performance requirements. As of 7/01/2011 Outdoor Water Use 4.304.1 Automatic irrigation systems installed at the time of final inspection ❑ ❑ shall be weather-based. A4.4 Enhanced Durability and Reduced Maintenance 4.406.1 Joints and openings.Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected ❑ ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Where a local jurisdiction does not have a construction and demolition waste management ordinance, a construction waste management plan shallX❑ ❑ be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the ❑ ❑ building occupant or owner. Page 2 of 5 CalGreen_2010.doc revised 08127111 ENVIRONMENTAL , Fireplaces 4.503.1 Install only a direct-vent sealed-combustion gas or sealed wood- ❑ El fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Duct openings and other related air distribution component openings ❑ El be covered during construction. 4.504.2.1 Adhesives, sealants and caulks shall be,compliant with VOC and ❑ ❑ other toxic compound limits. 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. ❑X ❑ 4.504.2.3 Aerosol paints and other coatings shall be compliant with product X❑ ❑ weighted MIR Limits for ROC and other toxic compounds. 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit ❑ ❑ finish materials have been used. 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. X❑ ❑ 4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance ❑ ❑ Schools(CHPS) Low-emitting Materials List or be certified under the Resilient Floor Covering Institute(RCFI) FloorScore program. 4.504.5 Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall comply with low formaldehyde ❑X ❑ emission standards. Interior Moisture Control 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. X❑ ❑ 4.505.3 Moisture content of building materials used in wall and floor framing is ❑ ❑ checked before enclosure. Page 3 of 5 CnlGreen_20/0.docrevised 08127111 Indoor Air Quality and Exhaust 4.506.1 Exhaust fans which terminate outside the building are provided in ❑ every bathroom. Environmental Comfort 4.507.1 Whole house exhaust fans shall have insulated louvers or covers .which close when the fan is off. Covers or louvers shall have a minimum insulation value of R-4.2. 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL OQUALIFICATIONS - Qualifications 702.1 HVAC system installers are trained and certified in the proper installation of HVAC systems. El 702.2 The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the discipline they inspect XO and verify. Verifications 703.1 Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen 2010.docrevised 08127111 CALGREEN SIGNATURE DECLARATIONS Project Name:. MartinoVlc addition Project Address: 20771 McClellan Rd., Cupertino, CA Project Description: 820 sq.ft. front addition SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1 —"Design Verification"and submit the completed checklist(Columns 1 and 2)with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2010 California Green Building Standards Code as adopted by the City of Cupertino. 1Z 20 Owner's Signature Date A L-EXA 1,i0E=2 rZtO iC Owner's Na (Please Print) /Z. !b . 20/3 Desi Professional's Signature Date *✓ z q P,'d40 Design Professional's Name (Please Print) Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance(Please Print) Phone Email Address for License Professional responsible for CalGreen compliance SECTION 2 — IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3,together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2010 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance(Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen 2010.docrevised 08/27/11 BUILDING ENERGY ANALYSIS REPORT PROJECT: Martinovic addition 20771 MCCLELLAN RD CUPERTINO, CA 95014 Project Designer: Nadia Pichko 1953 O'Toole Way San Jose, CA 95131 (408) 646-2195 'lop,Report Prepared by: Igor Pichko, CEPE Plar San Pedro, CA 90731 TA (424) 477-2127 SUL5WITI" A , . 1 . _ Job Number: 201312063 DEC 202013 Date: 12/16/2013 The EnergyPro computer program has been used to'perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16714:55:05 0:201312063 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 10 HVAC System Heating and Cooling Loads Summary 13 EnergyPro 5.1 by EnergySoft Job Number: ID:201312063 User Number:20658 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Martinovic addition ❑ Multi Family m Existing+Addition/Alteration 1211612013 . Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Stories 20771 MCCLELLAN RD CUPERTINO CA Climate Zone 04 2,332 820 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavit (ft) Features (see Part 2 of 5) Status Wall Wood Framed None 705 Existing Wall Wood Framed None 152 Existing Door Opaque Door None 18 Existing Floor Wood Framed w/Crawl Space None 1,512 Existing Roof Wood Framed Attic R-11 1,496 Existing Wall Wood Framed R-13 477 New Wall Wood Framed R-13 221 New Floor Wood Framed w/Crawl Space R-19 820 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Front(S) 43.5 1.280 0.80 none none Bug Screen Removed Left(W) 23.5 1.280 0.80 none none Bug Screen Existing Rear(N) 66.0 1.280 0.80 none none Bug Screen Existing Rear(N) 52.0 0.770 0.70 none none Bug Screen Existing Right(E) 50.0 0.580 0.65 none none Bug Screen New Right(E) 40.0 0.530 0.53 none none Bug Screen New Skylight 16.0 0.580 0.65 none none None New Front(S) 79.0 0.580 0.65 none none Bug Screen New Front(S) 40.0 0.530 0.65 none . none Bug Screen New Skylight 16.0 0.580 0.65 none none None New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 75%AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Existing FAU&A/C Ducted Ducted Attic,Ceiling Ins,vented 2.1 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12.16T14:55:05 ID:201312063 Page 3 of 13 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type 10 Single Family ❑Addition Alone Date MartinoviC addition ❑ Multi Family 0 Existing+Addition/Alteration 12116/2013 Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories 20771 MCCLELLAN RD CUPERTINO CA Climate Zone 04 2,332 820 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes IZ1 No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes El No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 804 New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status WATER HEATING Qty. Type Gallons Min. Eff Distribution Status Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16T14:55:05 10. 201312063 Page 4 of 13 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Martinovic addition ❑ Multi Family Existing+Addition/Alteration 12/16/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16714:55:05 ID:201312063 Pa e 5 of 13 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Martinovic addition ❑ Multifamily ❑Existing+Addition/Alteration 12/16/201 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/V r Space Heating 75.35 60.97 14.37 Spade Cooling 42.65 48.58 -5.92 Fans 14.54 14.07 0.47 Domestic Hot Water 17.61 17.61 0.00 Pumps 0.00 0.00 0.00 Totals 150.14 141.22 8.92 Percent Better Than Standard: 5.9 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 330 119 Fuel Available at Site: Natural Gas (vt7 290 24 Raised Floor Area: 2,332 (N) 823 118 Slab on Grade Area: 0 (E) 480 90 Average Ceiling Height: 8.7 Roof 2,332 32 Fenestration Average U-Factor: 0.78 TOTAL: 383 Average SHGC: 0.68 Fenestration/CFA Ratio: 16.4 REMARKS STATEMENT OF COMPLIANCE This.dertificate of compliance lists the building features and specifications needed r -C.ABEC � to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Plar ���� I or Pichko, CEPE 12/16/2013 Address Name 9 Cit /S tate/Zip San Pedro, CA 90731 Phone (424)477-2127 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Nadia Pichko 11 9p�("�/ Address 1953 O'Toole Way Name Nadia Pichko 1�.1�0 V City/State/Zip San Jose, CA 95131 Phone (408)646-2195 Signed License# Date Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16T14:55:05 0:201312063 Page 6 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name m Single Family ❑Addition Alone Date Building Type Martinovic addition ❑ Multi Family m Existing+Addition/Alteration 12/16/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments well 221 0.356 None 180 90 Remove 4.3.1-A1 Existing Home Door 20 0.500 None 180 90 Removec 4.5.1-A4 Existing Home we// 217 0.356 None 270 90 Existing 4.3.1-A1 Existing Home Wall 80 0.356 None 270 90 Removec 4.3.1-A1 Existing Home we// 314 0.356 None 0 90 Existing 4.3.1-A1 Existing Home we// 174 0.356 None 90 90 Existing 4.3.1-A1 Existing Home we// 80 0.356 None 90 90 Removec 4.3.1-A1 Existing Home Wall 152 0.356 None 0 90 Existing 4.3.1-A1 Existing Home Door 18 0.500 None 0 90 Existing 4.5.1-A4 Existing Home Floor 1,512 0.097 None 0 180 Existing 4.4.1-A1 Existing Home Roof 1,496 0.079 R-11 0 0 Existing 4.2.1-A2 Existing Home Wall 211 0.102 R-13 180 90 New 4.3.1-A3 New Addition Wall 50 0.102 R-13 270 90 New 4.3.1-A3 New Addition we// 216 0.102 R-13 90 90 New 4.3.1-A3 New Addition we// 221 0.102 R-13 0 90 New 14.3.1-A3 I New Addition Floor 1 820 0.0371R-19 0 180 New 4.4.1-A4 INewAddition FENESTRATION SURFACE DETAILS ID Type Area . LI-Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 43.5 1.280 Default 0.80 Default 180 Removed Single Metal Clear Existing Home 2 Window 23.5 1.280 Default 0.80 Default 270 Existing Single Metal Clear Existing Home 3 Window 66.0 1.280 Default 0.80 Default 0 Existing Single Metal Clear Existing Home 4 Window 52.0 0.770 Default 0.70 Default 0 Existing Sliding Glass Door Default Existing Home 5 Window 26.0 0.580 Default 0.65 Default 90 New Double Non Metal Clear Existing Home 6 Window 40.0 0.530 Default 0.53 Default 90 New Sliding Glass Door Non Metal Ti Existing Home 7 Skylight 16.0 0.580 Default 0.65 Default 0 New Double Non Metal Clear Existing Home 8 Window 79.0 0.580 Default 0.65 Default 180 New Double Non Metal Clear New Addition 9 Window 40.0 0.530 Default 0.65 Default 180 New French Door New Addition 10 Window 24.0 0.580 Default 0.65 Default 90 New Double Non Metal Clear New Addition 11 Skylight 16.0 0.580 Default 0.65 Default 0 New Double Non Metal Clear New Addition (1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 None 1.00 8 Bug Screen 0.76 9_Bug Screen 0.76 10 Bug Screen 0.76 11 None 1.00 Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16T14:55:05 ID:201312063 Page 7 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Martinovic addition ❑ Multi Family ❑ Existing+Addition/Alteration 2/16/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavit Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 804 0.031 R-30 0 0 New 4.2.1-A20 New Addition FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments (1) Ll-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H I Dist Len H t Ener Pro 5.1 by Ener Soft User Number:20658 RunCode:2013-12-16714:55:05 0:201312063 Page 8 of 13 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R Project Name Building Type ❑ Single Family ❑Addition Alone Date MartinoviC addition ❑ Multi Family ❑ Existing+Addition/Alteration 12/16/201 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existing Altered Removed Volume Year Built Existing FAU&A/C Existing+Alterations 1,512 12,096 1961 Addition 820 8,200 Totals 820 1,5121 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status Existing FAU&A/C 1 Central Furnace 75%AFUE Split Air Conditioner 8.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts System Name Heating Cooling Duct Location R-Value Tested? Status Existing FAU&A/C Ducted Ducted Attic, Ceiling Ins, vented 2.1 ❑ Existing WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. Type Distribution Btuh al or RE Pilot Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft 0 ro Pipe Pipe Insul. Control Qt . HP Plenum Outside Buried Q S S stem Name Length Diameter Thick. Ener Pro 5.1 b4 Ener Soft User Number:20658 RunCode:2013-12-16T14:55:05 0:201312063 Page 9 of 13 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date Martinovic addition 12/16/2013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R, CF-1 R-ADD,or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC ,and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulat ing Material. Indicate type and include on CF-6R Form. §118(1):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(i)when the installation of a Cool Roof is specified on the CF-1 R Form. *§150(a):Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50 c : Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. §150(f):Air retarding wrap is tested labeled,and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. 150 :Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1A:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113: HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve,backflow prevention, pump isolation valve, and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 1 12 c . §1500)1 A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2:Cooling system piping (suction,chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table 123-A. §150(')3A:Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance,and wind. §1 50@3A:Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number.20658 RunCode:2013-12-16T14:55:05 0:201312063 Page 10 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Martinovic addition 12/1612013 §150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181,UL 181 A,or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150(m)1:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. §150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight,moisture, equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light- §1 14(b)l: i ht_§114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 :Residential pool systems orequipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150 Residential Lighting Measures: §150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2. 150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a medium screw-base socket. 150(k)6:Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150(k). §150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer,energy management system(EMCS),or a multi-scene programmable control system;and all permanently installed luminaries in garages,laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number:20658 RunCode:2013-12-16T14:55:05 ID:201312063 Page 11 of 13 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Martinovic addition 12/16/2013 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages,laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2:Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms,garages, laundry rooms, closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2,0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units,entrances, balconies, and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptionl to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket,and consume no more than five watts of power as determined according to§130(d). §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number:20658 RunCode:2013-12-16T14:65:05 ID:201312063 Page 12 of 13 4 . HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Martinovic addition 12/16/2013 System Name Floor Area Existing FAU &A/C 2,332 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG.PEAK Heating System CFM Sensible Latent CFM Sensible Output perSystem 55,000 Total Room Loads 938 31,502 929 962 48,777 Total Output Btuh 55,000 Return Vented Lighting 0 Output Btuh/s ft 23.6 Return Air Ducts 2,578 4,992 Cooling System Return Fan 0 0 Output perSystem 42,000 Ventilation o 0 0 0 0 Total Output Btuh 42,000 Supply Fan 0 0 Total Output Tons 3.5 Supply Air Ducts 2,578 4,992 Total Output Btuh/s ft 18.0 Total Output s ft/Ton 666.3 TOTAL SYSTEM LOAD 36,657 929 1 58,762 Air System CFM perSystem 1,000 HVAC EQUIPMENT SELECTION Airtlow cfm 1,000 Existing FAU 8 A/C 37,892 0 55,000 Airflow cfm/s ft 0.43 Airflow cfm/Ton 285.7 Outside Air % 0.0% Total Adjusted System Output 37,892 0 55,000 Outside Air cfm/s ft 0.00 (Adjusted for Peak Design conditions) Note:values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 28 OF 68 OF 68 OF 119 OF Outside Air 0 cfm Supply Fan Heating Coil 117 OF 1,000 cfm �ROOM 68°F 70 OF �41 4 LTT...... U 4 COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Coolie Peak 88/68 OF 80/58 OF 80/58 OF 45/43 OF Outside Air 0 cfm Supply Fan Cooling Coil 47/44 OF 1,000 cfm 27.0% ROOD SO 158 OF 78 58 OF EnergyPro 5.1 by EnergySoff User Number:20658 RunCode:2013-12-16T14:55:05 ID:201312063 Page 13 o"3