Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14110026
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10271JOHNSON AVE CONTRACTOR:SOLARCITY PERMIT NO: 14110026 OWNER'S NAME: JASON PARK 3055 CLEARVIEW WAY DATE ISSUED: 11/05/2014 OWNER'S PHONE: 6507937496 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL E] INSTALL 8 ROOF TOP,FLUSH MOUNTED PV PANELS License Class # � (2.08KW) r Contractor Date I hereby aff� at I am licensed under the provisi s of .hapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$4000 ave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:37518030.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYSJEILL LED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply :i=ssued by: Date: with all non-point source regulations per the Cupertino Municipal Code,Section RE-ROOFS: Signature Z_9,�4� Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See,7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: Date• permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date _ OAOALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION O 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 \ (408)777-3228• FAX(408)777-3333• building o1cupertino.org CUPERTINO PROJECT ADDRESS APN# 'r OWNER NAME HONE ! J E-MAIL �fww �" -lro STREET ADDRESS CITY, STATE,ZIP FAX 1 CONTACT NAME PHONE E-MAIL �-1 30- aLam ET ADDRESS CTTY,SATE,ZIP FAX v �o A ❑ OWNER ❑ OWNER-BUILDER ❑ OWNERAGENT CONTRACTOR ❑CONTRACTORAGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT C�NTRACTORNAME LI OBE LIC�ENSm�YPE BUS.LIC# c_cda COMPANY NAME E-MAIL v �J FAX So 1 } 0. STREET ADDRESS CITY,STATE,ZIP PHONE 3 ` W� Yg CL G 0 830- ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS - - CITY,STATE,ZIP PHONE USE OF P)SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FORSOLARPANELS. NUMBER OFPANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): O TOTAL VALUATION: Q DESCRIPTION OF WORK 1 G� l� s 1 �= p$ `:k ,5 81yv ,c By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating t build' construction. I auth ' representatives of Cupertino to enter the above-identified pr perry for inspection purposes. Signature of Applicant/Agent: Date: S PPLEMENTAL INFOPMATION REQUIREDr, oFRicEusE oi` Y -� ❑ OyF.lt THE-r;OLINTER�i r ?� s A V 3. K%4, v r�� ��7'�xPREss j FSI� n I0{ ya tix3ra t Er x: ❑ STAI\DARI1� t ) .k +moi t Y :R w vzaRti�")� z<lj ❑'. BARGE rIt�, .a�4'�= " ;j . x' res rahs MAJOR w _. 4 N U.y _.; PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10271 JOHNSON AVE DATE: 11/05/2014 REVIEWED BY: MELISSA APN: 375 18 030 BP#: `VALUATION: 1$4,000 'PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RE USE: PERMIT TYPE: ; WORK INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS 2.08k SCOPE Lj NOTE; This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-0153 Eff 7i1--%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: (j) Reg. Q OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:(F) Reg. ® OT 1 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? ® Yes E) No $0.00 E) Advanced Planning) Fee: $0.00 Select a Non-Residential Building or Structure 0 Strong Motion Fee: IBSENMICR $0.52 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.52 $236.00 TOTAL FEE-T $237.52 Revised: 10/01/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE PLOT PLAN:!) EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY CHECKED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. "CNItJU,NITY DE�, EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING ELOPI�IENT ;EpARTtj��fi OAT f -� GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN E3UILDIN(3 DI\ASION _ LUPE GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. APPROVED RTINO GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL This set Of plans :3 1 ; a . PLANNING DEPT. HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) p c flcaba,; t,t _T 5e kept a�lh& O ob si e Burin �.�;,� I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER g str ,action. It is un;a,.,,v to make anry DATE Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR changes Of ` lteratfons an same or to deViat� Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC rarCF'G ;t;}oufaaproual from rh,. 4L;Ihin �. kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). Thi atrt cf ; i g OKClac 131.DG. DEPT. kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN �held r S SHALL N(C)) LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY R� b "4�1 of p'e v'oia�ic^� MIN MINIMUM UL LISTING. M�h rd,nUncO or, tafe Lau> (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE , �'Up�RTINO NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING DU OC ON CENTER HARDWARE. "-'x TT Building Depatrenr PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND ''j NOV O 5 2014 PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. \ SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTORREVIEWED AOR CODE COroPUANCE OFFICE SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & COPY STC STANDARD TESTING CONDITIONS 690.47. Reviewed By ? f✓/,� TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT W WATT VICINITY MAP INDEX W 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES jA PV5Cut THREE LINE CutTHREE Attache����r�� CA # 888104 1. THIS SYSTEM IS GRID—INTERTIED VIA A C-10 UL—LISTED SOYSTEM CHAS INIONING INVERTER. BATTERIES, O UPS. N 0 V 0 `� ?.G]g 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. , By 4. ALL WORK TO BE DONE TO THE 2013 MODULE GROUNDING METHOD: SLEEKMOUNT CALIFORNIA BUILDING CODE. AHJ: Cupertino 5. ALL ELECTRICAL WORK SHALL COMPLY WITH IREV BY DATE COMMENTS p THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY REV A NAME 1/6/2014 COMMENTS 70 THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company (PG&E) 0 D q11 Ge.olodiced- Surv6y.'USDA--Egrrn e -v'c e A-c 4'1�C CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-9502511 0 0 PRESSE OWNER. DEQ¶°" DESIGN PARK, JASON PARK RESIDENCE Lindsay Stone `?�,SolarCit . CONTAINED SHALL NOT BE USED FOR THE ■ NOR ESHALL IFIT OF TNBE DISCLOSED IYONE EXCEPT NLWHOLE ORARCITY CIN M01 m Mo 10271 JOHNSON AVE Api PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C 2.08 KW PV ARRAY ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ 3055 aearriew way CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE T:(650)638-102Sm 8 F:(650)638-1029 PERMISSION OF SOLARCITY INC. 6507937496 PV 1 10/31/2014 ( () ) ABB PVI-3.0—OUTD—S—US—Z—A COVER SHEET (888)-SOL-CITY ass-24x9 www.9alarcIty.aam 1 PITCH: 18 ARRAY PITCH:18 MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle STORY: 1 Story c� Y V J C CUPERTINO 8WIding Qepat-nen! i> Q PE%/;E='lVC---D r-'OR CODE COMPLIANCE o ilev:ewed By co c (E) DRIVEWAY o 3' FSB MPI o LEGEND w0 LG) 9 e O (E) UTILITY METER & WARNING LABEL to W INVERTER W/ INTEGRATED DC DISCO L-e�] e e & WARNING LABELS ® DC DISCONNECT & WARNING LABELS A PV3 © AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS F DISTRIBUTION PANEL & LABELS Front Of House LC LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR --• CONDUIT RUN ON INTERIOR GATE/FENCE O Inv I. � INTERIOR EQUIPMENT 7 L-"J r O (DN G) TOTAL ARRAY AREA (SF): 145 SITE PLAN a TOTAL ROOF AREA (SF): 2129 Scale: 1/8" = 1' W E TOTAL ARRAY AREA IS a 6.81 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL — THE INFORMATION HEREIN FMOUN-nNG PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THEJ B-9502511 00 PARK, JASON � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., +: PARK RESIDENCE Lindsay Stone �. �SolarCityNOR SHALL IT BE DISCLOSED IN WHOLE OR INunt Type C 10271 JOHNSON AVE 2.08 KW PV ARRAY �. '►IN •PART TO OTHERS OUTSIDE THE RECIPIENTSORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ 3055 geQvler Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET' REV' DATE' T:(650)Son Mateo, F.-(650)238-1029 PERMISSION of SOLARCITY INC. ABB PVI-3.0-OUTD-S-US-Z-A 6507937496 SITE PLAN / / P V 2 10 31 2014 (e8e)-sa-aTr(765-2489)..,..sdarcRy.com S1 4" 4' '-4 11'-6» (E) LBW SIDE VIEW OF MPl NTS A MPI X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT off Oil RAFTER 2X8 @ 24" OC ROOF AZI 179 PITCH 18 STORIES: 1 ARRAY AZI 179 PITCH 18 C.J. 2X10 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT - - . C QF'ER ( IN® ZEP ARRAY SKIRT (6) HOLE. = iSL ddin,g DPpaFtrrTero (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. .+ t-wv a 5 2-614 ZEP FLASHING C (3) (3) INSERT FLASHING. .pct It;` L '-(.R C"'Lr- WklPLIANCE- (E) COMP. SHINGLE (1) `y (E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULESINSTALL LEVELING FOOT WITH (2-1/2» EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER S1 STANDOFF CONFIDENTIAL — THE INFORMATION HEREIN O NUMBERPREMISE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-9 5 0 2 511 0 0 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: PARK, JASON �."� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10271 JOHNSON AVE PARK RESIDENCE Lindsay Stone �:;;SolarCity. Comp Mount Type C 2.08 KW PV ARRAY '�'"° PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINO, CA 95014 3oss a �■way ORGANIZATION, EXCEPT IN CONNECTION PATH THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV. DATE SonT:(650)638 Mateo,028CA 94638 -1029 PERMISSION OF SOLARCITY INC. ABB PVI-3.0—OUTD—S—US—Z—A 6507937496 STRUCTURAL VIEWS P V 3 10/31/2014 (666)-sa-aTY(765-24e9)rwr.edaraty.com UPLIFT CALCULATIONS GOPERl�INO �3 u tiding DeDartrnen. - 10.3 .2M4 5 2014 ;SolarC�t on#17.6 U y SleekMountT"' PV System -� �i ✓ ii rUR p C���pLIANCE Structural Design Application kevie",La ey Project Information Risk Category: II PV System Type SolarCity SleekMount- Comp Roof Comp Roof Number of Layers 1 Roof Slope 180 Rafter Spacing 24"O.C. PV System Module Orientation Landscape PV Module Area 142 sf PV Module Width 39" PV ModuleLength66" Standoff Attachment Hardware Comp Mount Type C Ground/Roof Snow Loads Ground Snow Load pg_ 0.0 Psf ASCE Table 7-1 Slunvundh*Roof Snow 0.0 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq:7.4-1 Wind Design�Cffls"a Wind Design Code ASCE 7-10 Wind.Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig.26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof Fig.30.4-2A/8/C-5A/8 Mean Roof Helght h 15 ft Section 26.2 Effective Wind Area 1 Module A 1 17.8 sf I IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic factor Kzt 1.00 Section 26:8. Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh=0.002562W2.4(Kzt)(Kd)N^2) Equatlon 30.31 psf Ext--Pressure Coefficient(Up) GCp(Up) -0.88 Fig.30.4-2A/13/C-SA/B Ext Pressure CoeNiclent Down Down 0.45 AD.30:4-2n/B/G5A/a Design Wind Pressure P p=gh G tion 30.4-1 Wind Pressure upP(up) -19.6 psf Wind Pressure Down down 16.0 Allowable Standoff Spadnigs x-Wrection Y Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape. 24" NA Standoff Configuration Landscape Not-Staggered Max Standoff Tributary Area TO 209 PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T ddual -196 lbs ,Uplift Capacity of Standoff T-allow 637 lbs Standoff Demand D(R 1 30.7% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9502511 0 0 PREMISE 094R DESCRIPTION: DESIG1t CONTAINED SHALL NOT BE USED FOR THE PARK, JASON PARK RESIDENCE Lindsay Stone �-`lf BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �3 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10271 JOHNSON AVE 2.08 KW PV ARRAY � h� oar ity PART TO OTHERS OUTSIDE THE RECIPIENTSMoES CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 pOW'vieW way THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ PA( NAME SHEET; REV DATE: son Mateo CA 9M02 PPERMSSIONCITY EOFIPSOLARCITY INC. THE wwrrEN PAGE 6507937496 PV 4 10/31/2014 (888)-SOL-CITY(7s58-24r8(9)www d'dtycom ABB PVI-3.0-OUTD-S-US-Z-A UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:Square D Inv 1: DC Ungrounded LINV —(1)ABBf PVI-3.0—OUTD—S—US—Z—A LABEL: A —(8)REC REC260PEZ CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1009594496 FCI inverter; Zigbee 3000W, 240V, 96% PV 4odule; 260W, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Overhead Service Entrance Voc: 37.8 Vpmax: 30.7 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL E) 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 PAR 20OA/2P 3 ABB PVI-3.0—OUTD—S—US—Z—A nf ) LOADS Ll 2aov SolarCity NGFP/GFCI 2 A 1 Vstart = DEFAULT 0A/2P —— _EGC! DC+ DCS A �--------------------------------------------- GEC -- I DC- Da MP 1: 1x8 3 13B EC—'C------------------------ —'---- --�-----------------� -- I I N I I EGC/GEC Z Z C7 GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I I I CUPER 1fIIVC3 j '.wilding Department `i P-OR CODE OUMiPLII NC.0- liE,-vlevved By ��G.x.• Voc* TT= MAX VOC AT MIN TEMP O1 (1)QUAREBreaker,D AAH�14,22 SpacesPV BACKFEED BREAKER /� A /� (1)S2dxa2�STRIINGS,SUNIFUSEDNGROUNDEDX DC 1 AWG 110, THWN-2, Black 1 AWG/10, THWN-2, Black Voc* =329.34VDC Isc =9.01 ADC (2)AWG#10, PV WIRE, Black Voc* =329.34VDC Isc =9.01 ADC O Isl— (1)AWG 110, THWN-2, RedO (1)AWG /10, THWN-2, Red Vmp =245.6 VDC Imp=8.5 ADC O (1)AWG#10, Solid Bare Copper EGC Vmp =245.6 VDC Imp=8.5 ADC LL LL(1)AWG 110, THWN-2, White NEUTRAL VmP =240 VAC Imp=14.5 AAC (1)AYn; /10, T I"72, Green_ _ EGC. . . .—(1)Conduit Kit;.3/4' EMT . . . . . . .-f1)AWP #8,.THR?I72,.9�W. . . EGC/GEC.-(t).Conduit,Kit;.3/4'.EMT. . . . . . . . . . PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-9502511 5 0 2 511 0 0 ����� ■ CONTAINED SHALL NOT BE USED FOR THE PARK, JASON PARK RESIDENCE Lindsay Stone �;;;So�arCity. NORBENEFIT SHA�LL ITNBENDISCLOSPED NoWHOLE RC OR RCIN MOUNTING SYSTEM: 10271 JOHNSON AVE 2.08 KW PV ARRAY ''"l PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: C U P E R TI N 0, CA 95014 3055 Clearyiew way THE SALE AND USE OF THE RESPECTIVE (8) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE San 1028 F. 94402 PERMISSION OF S"CITY INC. INVERTER- ABB PVI-3.0-OUTD-S-US-Z-A 6507937496 THREE LINE DIAGRAM PV 5 10/31/2014 (888)—SOL—CI TY 65 2489)www. ci�com WARNING:PHOTOVOLTAIC POWER SOURCE PV SYSTEM WARNINGLabel Location: Label Location: Label Location: ' Per Code: DISCONNECT FOR •'- CRC R331.2UTILITY OPERATION ELECTRIC SHOCK HAZARD CEC •. THE DC CONDUCTORS OF THIS Label Location: PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN PHOTOVOLTAIC DC MAY BEOENDERG ZED DISCONNECT UNGROUNDED CEC .•0 .14.C.2 Label Location: WARNING Per „- ELECTRIC SHOCK HAZARD 690.17 Label Location: DO NOT TOUCH TERMINALS MAXIMUM POWER TERMINALS ON BOTH LINE AND POINT CURRENT(Imp) A Code: LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER-_VCEC «. IN THE OPEN POSITION POINT VOLTAGE(Vmp) MAXIMUM SYSTEM V VOLTAGE(Voc) SHORT-CIRCUIT_ CURRENT(Isc) A Label • • WARNING '' Per ..- INVERTER OUTPUT CONNECTION Label Location: DO NOT RELOCATE THIS OVERCURRENT WARNING = Code:Per DEVICE ELECTRICAL SHOCK HAZARD CEC • 0.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTIONPer SOLAR MODULES ARE Code: WARNING:ELECTRIC SHOCK CEC .0.54; CEC . EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN 0.17 POSITION. FOR SERVICE , --,.:., •- • • DE ENERGIZE BOTH SOURCE WARNINGAND MAIN BREAKER. • PV POWER SOURCE � '` ELECTRIC SHOCK HAZARD Code:Per MAXIMUM AC A �; IF A GROUND FAULT IS INDICATED CEC '9 OPERATING CURRENTNOV 0 5 2014 NORMALLY GROUNDED MAXIMUM AC _ V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZEDCOM'PLIANCE Label • • Label; (POI) CAUTION '_ '',- Disconnect PHOTOVOLTAIC AC C •.- PHOTOVOLTAIC SYSTEM «9 0 «, . , o d uit CEC DISCONNECT 690.14.C.2 •' 4 CIRCUIT IS BACKFED :. . Distribution Panel (DC): D - . Disconnect Location:Label Location: -. DC Disconnect MAXIMUM AC CAUTION Inverter OPERATING CURRENT A DUAL POWER SOURCE ''• Center Per Code: - ••- MAXIMUM AC6. SECOND 50URCE ISCEC 705.12.D.7 OPERATING VOLTAGE _ Vy Meter PHOTOVOLTAIC SYSTEM (POI): Point of Interconnection 3055 Cleaview Way • . r . � • « . w' ' •� ' ' SolarCity SleekMountTM - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and •Interlock and grounding devices in system UL 0 Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system. SleekMount as"Grounding and Bonding System" • Insert Comp Mount flashing under upper utilizes Zep Compatiblelm modules with .Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device . Place Comp Mount centered Zep Solar standoffs,effectively eliminating the •Painted galvanized waterproof flashing upon flashing need for rail and reducing the number of g p g standoffs required. In addition, composition .Anodized components for corrosion resistance 0 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this \ , with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions ® Secure Leveling Foot to the Comp Mount using machine Screw • Place module Components B 0 5/16"Machine Screw • Leveling Foot • Lag Screw ® Comp Mount • Comp Mount Flashing F3CPEF���INO ding NOV 0 5 1014 0 ® REV(EWEb rpR ;ODE COAAPLJANC-�- Reviewea By _S�a. rAr So�arCitV �SwititV January 2013 J. January 2013 LISTED Jm A Additional highlights: e ' — RS-485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and sa,� Interruption(-A Version). Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US A= Mechanical specifications Mir Nominal output power 3000W 3600W 1woo 3800W 420OW .............................................................................................................. ............. Maximum output power wattage 3000 33001 33b0t . 3600 s 40001 40001 3300 . 42001 42001 . 4200 48001 . 46001 w w w w w w w w w w w w ........................................_............................... Rated grd AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 27N Input side(DC) Number.of.independent MPPT channels2 2 2 2 um Maximum usable power for each channel 2000W 3000W 30WW 3000W .. ......_. ...... ................................................. Absolute maximum voltage(."n 600V Start u volt e N start200V ad'.120-350 Full power.MPPT voltage_range.....................................................160-530V.....................................120-530V..................._...................................140-530V....................................140-530V................... Operating MPPT voltage range 0 7 x Vstart 580V(> 90V) • Max mum current(Idcmax)for botfi MPPT in arallel OA 32A 32A 32A Maximum usable current per channel tOA.............." ..................16A................... ......_............16A...................................................16A.......................... ..........:........................le,......,.....................an Maximum short circuit current limitper ; 12.5A 20 OA ` 20 OA channel 20 OA Number of wire landing terminals per channel 2 pairs ................................................................................................................................................................................................................................................................................................................................................... ,,,d,..:n�•. Arra wirin termination Terminal block,pressure clamp,AWG10-AWG4 Output side AC ° Grid connection type Ifelf plit- 1 1 -s—plil- i 1 ! 1 / p R- to/ split- 2W........0/3W........?W...........?w......i._0/3W....._.?W......i...._ZW.....-0/3W........?!C.......... !�...s._0L3W_...... W....._ 1g3- 2i 1- 244- 183 2i i- 244- 183- 211- 2aa- 183 € 2.1- zaa- ` Adjustable voltage range(Vmin-Vmax)M 228V 264V i 304V i 228V 264V 304V 228V 264V 304V 228V i 264V 1304V Y .......................................6 ......................................... Grid frequency...............................................................................I. 60Hz ....................................................................................................................................................................................................................................... Adlustable grid frequency range 57-60.5Hz Maximum current(Is.,) ia.5 1a.9" 12:b ' 17:2 " 16.0 "is'ti"' 16.0 ' 16`6 1s:b"""2b b "20:0' 20:b''' Pa.s........Aw.s....:.....°ro.s........! s....:.....�ws.._'.....Aws.......Aws....:.....pPo.s....:.....4ws....:.....Aw,s.........Aw.s..........Aaµs..... Power factor >0.995 .............................................................................................................`...................................................................................................................................................................................! ...................... Total harmonic distortion at rated power <2% ... This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wenn termination type Terminal block,Pressure clamp,AWG1O-AWG4 UPERTINO — II h output Input protection devices F inverters complements the typical time power tracking and improved Single phase and split phase ou p 3LJIIC/j� Depa Reverse polarity protection Yes ` rf nary number of rooftop solar panels energy harvesting. grid connection. over volts e_.rotection type Vanstor 2 for each channel t g P yP ... enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV arra round fault detection Pre start-up Riso and Dynamic GFDI(requires floatin a yg n �01� efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection deviceU s Y - Anti-islanding..protection........ .................................. Meets UL 1741/IEEE1547 requirements......... of the property. a consistent and stable performance The high speed and precise MPPT ----- .. --- - -- -'--'---""-'' "' Over-volts ag..... ro..tec...t..io...n....t..yPo.. .................:......................................,.....................................................V..a.r,i.t r...2....(LS..._�./..L..1..-..G... ).......,.......................j,.. .� - across the entire input voltage and algorithm offers real time ower Maximum AC 0CPD Rating 20 20A_,i 15 25 P 9 9 P 9 A°..< /4..<s A.. ..20A°,,, 20A,,,Q:20A°..<:20A,..< 20A°..< ��2`��1� L �u CO Efficiency This inverter offers a dual input output power range. tracking and improved energy y ANt,r Maximumefficiency........................................................... 96.9% I ................97%................................................97%........................................�`� section that processes two strips The transformerless operation gives the harvesting. �0eW P 9 P 9 9• CECefficiency 96% efl...BY with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <D.fiwm,< This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <8w,< Communication installations with two different installations with reduced string size. — Integrated DC disconnect switch user-interface 16 characters x z lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a complete y sealed Standards(S Version). Environmental Ambient air operating tem erature range -13°F to+140°F with derating.above 1"22°F(50°C) P g example:East and West) unit able to withstand the harshest Ambient air storage temperature range 40°F to+176°F(4b C to+80°C) ... ..... ....... Thedual input sections with environmental conditions. Relative humidit....................................................................................................................................................0-.100%RH condensin9........................................................................................... Acoustic noise emission level <50d b(A)�1 m Independent MPPT enable a more ...................................................................................................................................................................................................................................................................................................................................... Maximum operating altitutde without derating 6560 ft 2000 m optimal energy harvesting condition. Power and productivity t Capability enabled at nominal AC voltage arid with sufficient DC power available. for a better world" 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD f: SEE PEAK ENERGY ZLINK 41, 10 25• • ®--0 +ar 15 sld 1�1 � ( • t All measurements in Inches a• Nominal Power-P.(Wp) 255 260 265 Watt Class Sorting-(Wp) x5 x5 x5 REC i,o71Nnes Nominal Power Voltage-Vt (V) 30.5 30.7 30.9 11.5 4f1� Nominal Power Current-1_(A) 8.42 8.50 8.58 1713E Y Open Circuit Voltage-Voc(V) 37.6 37.8 38.1 Anosf�edatolxaaa)at(k perOrr-riance Sow P31�=5'ld[1 Short Circuit Current-Ist(A) 8.95 9.01 9.08 7ep6satwes rtp PanelEfficiency(%) 15.5 15.8 16.1 IIL IP67rated ;l'' 4 mixt solat cabte,47"-17' 1 ' The electrical characteristics are within•/-10%of the indicated values of li�rr,Vi andlo at standard Test conditions(STC). _ Values at standard test conditions STC(aumass AMI 5,irradiance 1000 W/m',cell temperature 25•C). At Irradianceof 200 W/ma(AM 15and cell temperature 25•C)at least 97%of the STC panelefncency will be achieved. Ij �1 fI ,a , Nominal Power-P (Wp) 193 ,,o, 197 202 Nominal Power Voltage-V,, M 28.5 29.0 29.4 Nominal Power Current-I.,(A) 6.77 6.81 6.90 Open Circuit Voltage-Vcc(V) 35.3 35.7 36.0 Short CircuitCurrent-Is,(A) 7.21 7.24 7.30 Nominal operating cell temperature NDCT(800 W/ma.AM 1.5.windspeed 1 m/s.ambient temperature 20•C). .a' 10 year product warranty. 6511 x39xIIf2(n(%65x991x40mm) e DIfs 25 year linear power output warranty "'" - fe(1.6Sm) LMN (max.degression in performan ce of 0.7%p.a.). UL 1703,Fire rating:Class C REC is a leading global provider of solar energy solutions. With more than 15 years of experience,we offer sustainable,high performing r �'• N� products,services and investments for the solar industry. Together with our partners,we create value by providing solutions that better - ' �i REC U f ER1 1 meet the world's growing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Ourl,600 (, / ff "U'Id'119 employees worldwide generated revenues of USD 647 million in 2013. I D��a'trnen► recgroup.com `f J NOV 0 5 2014 t��IEVVEC; f�OR CODE COMPLIANCE Itevlga,�a By f7 ;'r � III►