14120038 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1478 PRIMROSE WAY CONTRACTOR:REC SOLAR,INC. PERMIT NO: 14120038 OWNER'S NAME: GREGORY KENT A ET AL 775 FIERO LN STE 200 DATE ISSUED: 12/08/2014 OWNER'S PHONE: 4082572294 SAN LUIS OBISPO,CA 93401 PHONE NO:(888)657-6527 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL 0 INSTALL 15 ROOF TOP,FLUSH MOUNTED PV PANELS(3.9 License Class li`I lY nLic.# 15U I S q I KW) Contractor U Yl�l►'1 -Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation:$9750 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36615020.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF P IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Date: O with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. ROOFS: any r Si at e [e y All roofs shall be inspected prior to y roofing material being installed.if a roof is installed without first obtaining an inspection,l agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BE'T'TER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code, ctioi 2 .05,25533,an 53 . Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. / �Z O /� Owner or authorized agen t Date: 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that i have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18, Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION 12 COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION O� 10300 TORRE AVENUE - CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333 • building(o)cuper ino.orq a, CUPERTINO PROJECT ADDRESS i U� qr B i n wose. V�1a APN k (o I z o OWNER NAMe I/r l �I Q Lr P Q�M' �� �s, /� E-MAIL STREET ADDRESS I ' (CqMnC), 7�- SG FAX CONTACT NAME 8c, ( 1 AI/(^STREET ADDRESS /�6jZ a _' v -''j l C STA Z C -1✓I ❑ OWNER 13OWNER-BUILDER ❑ OWNER AGENT L] /cINTNTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME�tA lu 1 C LICENJ1701+ LIC E PP€/n BUS.LIC N COMPANY NAME E-MAIL o � FAX STREET ADDRESS !y, , + „I - CI ,S ATE,ZkPFElts ARCHITECT/ENGINEER NAME (� LICENSE NUMBER BUS..LIC 9 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes ❑ No OLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION 1:1SOLAR WATER HEATING 1:1 OTHER: FORSOL4R PANELS: NUMBER OF PANELS/UNJTS: j G KILOWATTS(COMMERCIAL ONLY): 2 TOTAL VALUATION: DESCRIPTION OF WORK FCRIVEDBY: By my signature below,I certify to each of the following: I am the property authorized agent to act on the property owwier's behalf. I have read this application and the information I have prov' is correct. I have read the escrip ' n of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b m nst I authorizer rese tiv Cup rtino to enter the above-identtifi property for inspection purposes. Signature of Applicant/Agent: SUPPLEMENTAL NFORMATION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER F' ❑ EXPRESS v U x ,❑ STANDARD U a ❑ LARGE .. ❑ MAJOR P VApp_201 1.doe revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 1478 PRIMROSE WAY DATE: 12/08/2014 REVIEWED BY: MELISSA APN: 366 15 020 BP#: j-3y VALUATION: $9,750 Zllz� RPERMITTYPE: Building Permit PLA CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR-RE WORK INSTALL 15 ROOF TOP FLUSH MOUNTED PV PANELS 3.9 kffl SCOPE El NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District,etc). These.fees are based on the reliminar information available and are only an estimate. Contact the De t or addn'1 info. FEE ITEMS (Fee Resolution 11-0.53 E(L 7,,1-'13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl. PC Fee: Q Reg. Q OT 1 0.0 1 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 SuppL Insp. Fee:Q Reg. C) OT 0 0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 (.tJ1�.1''I'c!['IIU➢i I GLC: irl1nmi7 fral c Fee. 0 Work Without Permit? 0 Yes No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential lint l l)�.��r,ra>>�:trxrhti Fc'�.ti Building or Structure 0 Strong_Motion Fee: IBSEISMICR $1.27 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 $2.27 $236.00 TOTAL FEE: $238.27 Revised: 10/01/2014 HIGH PERFORMANCE SOLAR MODULES RE[ PEAK ENERGY BLK REC Peak Energy BLK Series modules are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. RK combines high quality design and manufacturing standards to produce high-performance solar modules with uncompromising quality. UMPOWER ROBUSTAND PERW DURABLEDESNX ENERGY PAYBACK OP7lFFZE6F{dRALL TM OF ONE YEAR SUNLKM CDNWI MiS �r Fd �� A REC PEAK ENERGY BLK 5ERIF- EFF)EB9[Y YEAR PRMJCT WARRANTY -� YEAR U EAR POWER D TFUT WARRANTY i : . . Mourt'vtgholes MorninalOperatingCellTemperature)NOCT) 45-7*Qt2•C) tur�CoetficientnfP a4El%/-C - car ie t� va -O.Z7%/-t �aTM TeanperarereCoefficiento€BSc =4%/-C EUCntCALDATA STC REC23M REC24CPE i. Cel[Type: 60 REC PE multi-crystalline Nominal Power-P�(Wp) 735 29fl Z45 292 255 20, 3strinpof 2D cells with bypass diodes aJ+s 0'+s C"-S 4 at-+S Glass: 3.2mm.sofargUmsWthartti-rettection Nominal Power Voltage-V,(V) 24.5 2!17 3M1! 322 335 311:7 surfacetreatmerrt Nominal Power Current-1,,p(A) 695 5.17 &B 63a 6.42 &'W, 8ack5heet: Double layer highly resistant polyester Open Circuit Voltage-V,(V) 35 Cr. 31ii;6 371 31.4 37.5 3g,$ Frame: Anodized aluminium(black) Short Circuit Current-Isc(A) ass 675 6ffi am M so function8ox: IF67'rated 4 ma+�solar cahfe,EL4m+T.2 m �AAasIY�.L q! T42 W-5 Ths T&1 as 16B Connectors: MC4(4rmtl) Analysed data demonstrates that%17%of modules produced have current and voltage tolerance of�M from nominal values. MC4,connectable(4m i-M Valuesatstandard test conditions STC(alrmassWIS.Irradiancet WW;� Radoxtwist ktcklt4mm,4 At lowirradiance o and celItemperature2TC.)atleast4 Nominal Power-.PM,(Wp) DJC 7B3 )PfT 119 7R M7 Operational Temperature: -4c?.-Q0`C Nominal Power Voltage-Vr,�(V) 275 27.7 291 253 285 292 MaxirrumSystem Voltage: II"V 6 Nominal Power Current-IM,(A) 7 6 �k rags Maximum Snow Load: 55a*fPrrimacPa) 55 Open Circuit Voltage-Voc(V) 342 3*4 347 35A 353 357 iMaxirr um Wind load 244 5g/m2(24t2€I Pa) Short Circuit Current-Isc(A) 61.96 ZO Z.R Z72 7211 7-74 MaxSerinFuseRating: 25 A Nominal operating cell temperature NOCT'( Atif[S. iwlaxREYerseCurrent: 25A z , (�] /�+w 19 year product warranty Dimensions: 1665 x491x3Bmm SII A-� 25 year linear power outputwarranty Area: i6�smT L Fol (max.degression.lnperformance op.a.) weight, 18 kg &IECl fMjX:&Z �r(ammonia resistance)& l(salt mist-severity level ®j. rv�cv=g tdstelSQeciC> serbiectttiaregewitltflartrrotice Member of PV Cycle £ l ifii7 1 � REC L products,services and investment opportunities forthe solarand electronics Industries.Togetherwith our,partners,we create valueby Q� + employees worldwidegeneratedrevenues ofmore *w:N@U7 billion in2MIZapprodwatelyEW11 billion. wwwrecgroup.com Page 1/2 REC Limited Warranty Certificate for REC Peak Energy Series Modules & REC Peak Energy Integrated Modules' (valid as of September 1,2011) This Limited Warranty is valid only in North America,Central America and South America'and for all REC Products(as defined above)sold after September 1,2011 or later. REC MODULES PTE.LTD.(hereafter the'Warrantor'or'REC')issuesthe following voluntary warranty to the end-user who purchased the Productin one of the above mentioned countries and put the Product into use for the first time(the'Original End-Userl. In addition to the rights under this Limited Warranty,the Original End-User maybe entitled to statutory warranty rights under applicable national laws which shall not be affected or limited in any way by this Limited Warranty. I. Product Warranty Subject to the terms and conditions of this Limited Warranty,REC warrants that the Products: • Are free from defects in material and workmanship for a period of 10 years from the date of purchase by the Original End-User(not exceeding a maximum period of 10.5 years from the date of production as identified on the Product)(the 'Warranty Period`)if installed and used in accordance with the installation instructions available to download from www. recgroup.com. • Will remain safe and operational if cable and connector plugs are installed professionally and are not permanently positioned in water:provided however,that damage to the cable caused by abrasion on a rough surface due to insufficient fixing or to unprotected running of the cable over sharp edges is excluded. Damage caused by animals is also excluded. • Will not experience freezing up of the aluminum frames if installed correctly. The outer appearance of the Product,including scratches,stains,rust,mould,discoloration and other signs of normal wear and tear,which occurred after delivery or installation,do not constitute defects,provided the functionality of the Product is not affected. Glass breakage constitutes a defect only if not caused by any external influence. If a defect occurs during the Warranty Period affecting the functionality of the Product,REC will,at its sole option: • Repair the defective Product. • Replace the Product with an equivalent product. • Refund the current market price of an equivalent product at the time of the claim. II. Power Output Warranty Subject to the terms and conditions of this Limited Warranty,REC warrants that the actual power output of the Product will reach at least 97%of the nameplate power out specified on the Product duringthe first year(calculated from the date of production as identified on the Product). From the second year,the actual power output will decline annually by no more than 0.7%for a period of 24 years,so that by the end of the 25th year,an actual output of at least 80.2%of the nameplate power out specified on the Product will be achieved. This Power Output Warranty covers only reduced performance due to natural degradation of the glass,the solar cell,the embedding foil,the junction box and interconnections under normal use. If the Product does not reach the warranted power output levels set out above when measured by the Warrantor or by an independent measuring institute agreed to prior to testing by the Warrantor,under standard test conditions(IEC 61215)and taking into account a t3%tolerance range,then REC will,at its sole option: • Repair the Product • Replace the Product with an equivalent product or to supply additional modules as necessary to achieve the warranted percentage of specified power output. • Refund the current market price of an equivalent product at the time of the claim 1 excluding modules showing"Q3"as part of the product name. z Defined as all member states of the Organization of American States,OAS. Rev.G.1,September 2011 This warranty is only applicable in the member states of the Organization of American States,OAS Page 2/2 III. Warranty Conditions,Limitations and Exclusions 1. This Limited Warranty is not transferable by the Original End-User,except to a subsequent owner of the solar power facility at which the Product was originally installed and remains installed,provided that this solar power facility has not been altered in any way or moved from the structure or property at which it was originally installed. 2. Notification of a warranty claim hereunder must be given without undue delay after detection of the defect and prior to the expiration of the applicable Warranty Period and in accordance with the procedure as set out in section IV below. 3. Please note that this Limited Warranty does not cover,nor will the Warrantor reimburse,any on-site labor or other costs incurred in connection with the de-installation or removal of defective Products,transport or the re- installation of replaced or repaired Products or any components. 4. The Warrantor may use remanufactured or refurbished parts or products when repairing or replacing any Products under this Limited Warranty. Any exchanged or replaced parts or Products will become the property of REC. The Warranty Periods set out in sections I.and 11.above will not be extended in any way in the event of a replacement or repair of a Product. 5. This Limited Warranty requires that the Product is installed according to the latest safety,installation and operation instructions provided by REC and does not apply to damage,malfunction,power output or service failures which have been caused by:(a)repair,modifications or removal of the Product by someone other than a qualified service technician; (b)any improper attachment,installation or application of the Product or(c)abuse,misuse,accident,negligent acts, power failures or surges,lightning fire,flood,accidental breakage,actions of third parties and other events or accidents outside REC's reasonable control and/or not arising under normal operating conditions. 6. This Limited Warranty is provided voluntarily and free of charge and does not constitute an independent guarantee promise. Therefore,if any defect materially affects the functionality of the Product or results in a power output below the warranted levels,the Original End-User's remedies are limited exclusively to the remedies set out under sections I. and II.in the warranty cases specified herein. REC ASSUMES NO WARRANTIES,EXPRESS OR IMPLIED,OTHER THAN THE WARRANTIES MADE HEREIN AND SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES,MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. REC EXCLUDES ALL LIABILITIES FOR ANY SPECIAL,INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES FROM THE USE OR LOSS OF USE OF THE PRODUCTS TO PERFORM AS WARRANTED;INCLUDING BUT NOT LIMITED TO DAMAGES FOR LOSS OF POWER,LOST PROFITS OR SAVINGS NOR EXPENSES ARISING FROM THIRD-PARTY CLAIMS.This does not apply to the extent the Warrantor is liable under applicable mandatory product liability laws or in cases of intent or gross negligence on the part of the Warrantor. 7. This Limited Warranty shall be governed by and construed in accordance with the laws of the State of California without giving effect to its conflict of laws provisions.The United Nations Convention on Contracts for the International Sale of Goods(1980)shall not apply to or govern this Limited Warranty or any aspect of any dispute arising there from. IV. Warranty Claim Procedure Claims under this Limited Warranty must be made by notifyingthe authorized distributor or seller where the Product was first purchased.A claim may be registered at: www.recgroup.com/warranty For a Warranty Claim to be processed,proof of the original purchase of the Product and any subsequent sales including transfer of this Warranty need to accompany the claim.The claim must include a description of the alleged defect(s)as well as the Product's serial number(s). Prior to returning any Products or components to REC,an RMA(Return Merchandise Authorization)number is required,which may be obtained by contacting REC via the aforesaid address. This warranty is valid for Products sold on or after 5eptemberl,2011. Singapore,01.04.2011 11 11 I ...... This warranty is only applicable in the member states of the Organization of American States,OAS Rev.G.1,September 2011 PVI-3,8-TL 3-' :C -RAL SPECIFICATIONS The most common residential inverter is the ideal size foran average- sized family home. This family of single-phase string invertex complements the typical number of rooftop solar panels, allowing home-owners to get the most efficient energy harvesting for the size of the property.This rugged outdoor inverter has.been designed �� H as a compietelysealed,unitto withstand the harsfiestenviro:nmental .r: conditions. One of the key benefits of the Uno family of single-.phase inverters is the dual input section to process two strings with'independent " MPPT especially use for:roo+;top.instaIlations with two,different orientations(ie East and West).The hlg h speed'MPPT offers feat-tune powertracking and ir. proved energy harvesting. The transformerless operation gives the highest efficiency of up to .97.0%. The wide input voltage range makes the inverter suitable to low power Installations with reduced string size. • Each inverter is set on specific grid codes.which canbe.selected inthefleld • Single phase outpun • Dual input sections with independent.MPPT,allows optimal energy harvesting from,two sub-arrays oriented in different directions - • Wide input range • High speed and precise MPPT aigorithm.for real time.power tracking and improved energy harvesting • Flat efficiency curves erasure high efficiency at all output levels ensuring consistent and stable performance across theentire input voltage and output power-range • Outdoor'NEIVMA 4X rated enclosure for unrestricted use under anyenvironmental conditions • Integrated DC disconnect switch'.in compliance with international.Standards(-S Version) • RS-485 communicaillon interface(for connection to laptop or dataloggec) • Compatibde with:PVA=RADIOMODULE for wireless corrxnlunication with Aurora f'VI-DESKTOP • Integrated Arc fault Detection and.Interruption(-A Version) TOLOCK D OA RAN Of PVT-3.0-OUT-D,PVII-.Lrar4DUTD,PVB-3;B-(OU D AND PWI-42"D STD FOR il@ORTH ANER'I CA ____ -_-• ----------. .11i1 MMT INI + I I I •I r DCIDQ IO EWFE ATEA N ry� }I rryy�� K OBULXCAPS IVAQ N13N1 JE p I INI IN1 N1) R I INI INI" J INIE GRIDPAAMIEt N INI.IO)I I - }- - - INt.I() -.•+ tf•-—y FLIER AEslAY 10 �T`}-_-IIS-(T'I Lr INI3LI U I -v I r • �v I 1 1 21B -----------------------T---, INl.l(+) I i 0KWT2 pr N .2 1(+)[]-- �+ N + s v Wl INl j i IW IN] I INi I j RESO)AL CLPRRan1 y ,y p WrEcnoN Y l IN21(•) IN3.1(-)Lr•�. _ INl1F1 _ l _N N „ 0' y F I I I Y ► P � Y 3 �1 PE A N bT d Y d P STANDARDVERSION AVERSION -S VERSION I a P I ;+ r F ASRBs I I :• � I +T/R T/R tr. M A =it 3X.94 QBs• .9.eY RN9OIE CONfROIc: 17A]J l:l JI �.I-A gglND � _ MIAT - P?tr I OETECTKIN ALARMI R N.0 NA c C CONTROLUACUrr .�.._.._....�____..__...-......._..-.._..._.-__—_-.._.._-.-.-.-_..,.�.-_+.w_•.-.��...._.._.._.. a0Td1(OnadNMllgl nor4NeWY on.A venbn Block • • and Efficiency Curve,-:, PV04.2-DUM-BAS 100. -I�A�1 91A -9SAOG 99; _yam 9l6 •B9.OB6 % •BOp0® 9 I -'IQpOM 98.] $$$y .5m� #gp 9le 95 ^.SSAOIL 8 :9N r ...SOAG qe' 81 w U.00ti By _per C 9A6 93 1 —70OVdc '34AOR •.. 91] —5n0 Vdc •lSAB16 rnY 91r 98OVdc '>a} .. 9� ."AM *.R Trxxa«^ --'yAOM 0% '10% 10% 70% 90% 50% 60% 70% 8076 90% 100% Inmw.•-- i r.tow. ',ala ils aB saB Bns Yoo neo %of Rated Output PowerIAPIava7rge M 'NominefOutputfower W 3000 .3600 3300 3800 4200 'Maximum Outputifower W 3000 33002 3300' 3600 4000' [ 4000' 3300 4200'_- 42001 4200 /46062 4600' Rated Grid AC Voltage V 208 240 277 208 240 277 .208 240 -277 208 240 .277 Input Stde"IDQ Number of independent MPPT;Cbannels 2 2 2 2 Maxim um Usable PowerforEach:Channel W 2000 30.00 3000 3000 Absolute Maldmum Veltage(Vmax) V 600 Start-UP Voltage O tert) V 200 fad_J.120.350) fullPowerMPPTVOItageRange V 160.530 129-530 146-530 *40.530 Operating MPPT.V.oltage Range V OJxVstart580(>=90V) Maximum Cufmig,(Idcmaz)torfioth MPPP In Parallel A 20 32 32 32 TWaxlmumUsableCurfentperCsbannel A 10 16 16 16 Maximum Sh ort Circuit Current Lim It per Channel A 12.5 20.0 20.0 26.6 'Number of Wlrelanding Terminals Per Channel 2 pairs ArrayWlringTerminatlon Terminal.block Pressure Cl amp,AWG10-AWG4 Output Slde lAQ 06*060;' Grid Connection Type 10/2W Split- 10/2W 10/2W Split- 10/2W. 10/2W Split- 1012W 1012W Split- 10/2W 0/3W 0/31V 0/3W 0/3W AdjustableVoltageRange(4minwVmax) V 183-228 211-264 244-304 183-228 .211-264 244304 183-228 2111264` 244304; 183.228 x;11-264 244-304 Grldfrequency Hz 60 Adjustable Grid F". uencyRange Hz 57.60.5 Maximum Currem"acma20 Apes 145 14.5 12.0 17.2 16,0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 Powerfactor >0.995 TotalflarmonlcDistortion AtRa%dPower % <2 GPId Wiring Termination Type Terminal'block,Pressure Clamp AWG10-AWG4 Protectlon Devices Input Reverse Polarity Protectloa Yes Over-Voltage Protection Type Varlstor,2 for each channel PVArray Gtoundfaul4 Detection Pre start-up Rfso and dynamic GFDf(Requires Floating Arrays) Output Antldeiandfng Protection Meets UL.1741AEE1S47 requirements wennalACOCPDfRating ARMs ,20 20 1S 25 20 20 20 20 20 25 25 25 Over4oli age Protectlon Type Varistor,2(L,-Ls/L,-G) Ef45ctensy Matdantrmlt�Tidetrey % 96.9 9-7 97 97 OCORdency % _ 96 Operating Performance 'Night Time Consumption Wwas <0.6 Stand Sy Consumption Wrws <8 Cammunhatlen User4mierface 16 characters x 2lines LCD display Aemote'Monitoring(1 xRS495 Imcf,) AURORA-UNfVERSAL(opt.) - - 1Nhedloca_I Monitoring(lnRS4651ncl.) PVf-USB-RS48Sj32(opt.),PVI-DESKTOP(optj PVI-DESKTOP(opt.)with )PVI-VI (opt.) WI►elesslocalMonitaring p. Environmental Ambient AlrOpersting'lemperatme Range 'F("C) -13 to+140!(-25 to+60)with derating above 122(50) Ambient AM Storage Temperatuselflange 'F(°C) -40 to 176(-40 to+80) Re)ative,Humidity %RH 0-100 condensing Acoustic'Nolse Brrllsrlenlevel db(A)@1;m <SO Maximum Operating Aftltude Witheut'Derathtg ft(ml) 6560(2000) i10eAsaeladS,pet 1"closure rating NEMA 4X Cooling Natural Convection Dimensions(H x1N"�D) ln:'(mmJ '39.8 x 12:8 x43J1(859 x 325 x 222) Weight Ib(kg)... <4Z3(21.3) Shipping Welght Ib(k9) <60(27.0) 'Mounting system Wall bracket Tradesizel( s;"(26'zY/2)and (tea x-14113 places side,-front,-rear) - Canduit.Connectlens2 Side:12)plugged 3/4"apeTdngs;(2)Concentdc EKOs 3M`,1" _ Back(4)Concentric EKOs 3/4`,1" DC Switchiiating-(Per4ontect) AN 25/600 SaTrety Isolation Level Transformerless(Floating Array) - --- - So%ty and @MIC Standard 1JL 1741,IEE1547,IEE1547.1,CSA-C22.2 N.107.1-01,UL1998 UL1699B FCC Part 15 Class 8 - - SafetyApprova) _ _._ - - .,CSA. Warranty Standard.Werranty years .10 ixtendedsWarranty years 15&20 AviaMeModels Standard-WlthoutDCSwtkh and'Wking Box PVI-3.0-OUTD=US PVI-3.6-OUTD-US PVI3.8-OUTD=US PVI=4.2-CUTD-US Standard-.WkhOCiwltch and.>RIIrMgdlox PVI-34OUTDS-1.15 _P OA OLFTD S US PVI38 0UTD-S-U5 PVf-4.1 OUTD-445 Wkh DCSiil4ch,lMririg(liezan'd sc nukDetectar ; RVI-3.0.OUTD-SUS A P,VI-3.6.OUTD-S-US7A PVI-3.8-OUTD-S-US A PVI.42-4.2 -U5-A andinterin. T _ 'All data'Is sublet(to Change wlthoutnoace " :Capability enabled abnomhral AC,vohaye.and wlth suf6dent DC poweravaaaale 1When egdippedwithoptWnalDCswadtcandMringBox - ,. w�%Iar�eae9ErwDd 1nd1Ao'PnTtlw% owootl twn, sK ODE 061 sit p- %w6,. a :%001 %06 %00 %O[ %09 %09' %oe 910E %oi %01. %a O6 *A 08V M. %WR. `1! IPAME— Z6 ry %w6r. m %073E- IPA OR a E6 lu; _ 9 lm tl1a' %Wss %0759- .96 ru %WU'_. go. Wsl Z6 9a 'Wa. 90756 Ile YDO'001- �%fJLYi'01EF�•Y' •.Z �',... 'R .lW 6�`i]SIGPLi� 9i� .LJ/ • A . f uqua�y-uo TpEOm louuoPxny pnuolwoww. ------------------ P 1 liutln wtluaJ ryN WtlYIY d(,'C ,moi �iouuroJ3lnwas �s .vy >= �+ w:xr ° Yv�c r y A tl/1•�'��' N � M y y S9Ktl ry •y y I 4 rt j >f j N I 4 g MOjSH3AS- NOISHRAu- NOISHMaaaOWIS ii u y _ n L �� �]•-- ' Iilz. - tell iNl T r - a "OIL 30 r � 1N3tl911JltlnUK3tl � ,CNI� iM r iNl� �LNI LNI� F ,-WI ifM`J(U }a I + lik'LNI N I i I I rt w I L 4 mo-• ^d+c / - _ ,NrINI - e AYl9tl %3EIN 13f19tlYd9A19 3NII R ovrlw N I rt .. « fir---{]IHI'IM – aLr–r--y.�I+IrIM RUTMN SdVJNY1B lllww � tl3stl3M11 IiddW klll'!M P Vl�M4d1 W'V 1!'S1 %IW 'S�Y.1114'Ytl.T` Y7U�Yil04 f/'®dY0'UiWL�'7.'QtlUlL4 T�i4NONa����IIOUtdFl+hAb11'llHll–N:la���7WL1-�1SY tl10lY Yi1O0111C IH.MOW. v 0 c 0 0 3 E v ALL 0 a E 2 :a m .o a N Powerd7ne Renewable Energy Worldwide Sales tis l 1'ame7Redron Teleohone l AUSUAO maPaclfic -+61 2 9735 31 71 salesausmTia@power-nne:cnm ChIna MaPaclfic +8575529885888 salestHma@PoWe>-aae.com h i+aU AsiaPatific +B621550 WD9 .sales.cbirra@pciwer-nnecorn MaNdfic +6568963363 saleLb&a@power-anexm J*= mrapadfic D3-45M,273V+813-858D-2774 miesj Rower-onecom S"MPoss mapadfic a-b5f)W.6mG3 sales. ngapnre@povrerunecam EmipivmJ7lre ] 9 Europe }322206D338 salesbelghrmQcpoonetnm +31D)14379614D sal esJrance@poweFnne:tom 1�nate Emope -3 47 419552020 es._WmaT,7@poweF-Qna;com C1�� Earope D®BDOD02876a2 salesWeece@power-me-tam Epe 08DDDD8salenpower-omSpam � +349 78834 saleLsWmAponer-boernm 01gdom Europe +447903 W30 salmuI*power-onecom lipid MiiddleEast +9n3.03M9142 saleidubai@power-wmcom lsmd XtdcDe Ease +-=03544 8884 :saleLaael@power-onezom oda NDrfbAmerJta 0 EV267--32-4 mImtaxodoppowei-oneetD.m vu fog NortbAmerin +9 W726J]37A salesn ower-onetom MC00A NortbAmefica �7W261-9,vi4 salesmaceomI@power-anecam %yam ND�hAmerJca �3 Ra'o 267-73,7x9 satestxsawest(�pov�er-qn� O - - REM"Ll N NOTES-SNAPHRACK _ w COMPOSMON L FOOT - 5/16' LAG BOLTS MUST EMBED ---CAN BE MOUNTED 2.5' INTO R0� STRUCTURAL - Z ANY ORIENTATION MEMBERSAWTERS _—�- p► - T1320UE ALL 5/16' HARDWARE TO SNAPNRACK THE FOLLOVRN - — CHANNEL NUT - SILVER S.S. 10-16 FT-LBS X 1' S.S. BOLT AND - BLACK S.S. 7-9 FT-LBS to - RAILS CAN MOUNT TO EITHER SIDE m SNAPNRACK SPLIT WASHER OF L FOOT CUPSLOPE VS DOVNSLOPE) L3 STANDARD m RAIL N S.S. FLANGE NUT STEP 3- PLACE L FOOT ON TOP O OF FLASHING AND TIGHTEN NUT O STEP 2- SLIP O FLASHING OVER O SHAPHRACK COMPOSITION L FOOT BASE -n ROOF FLASHING STEP 1t BOLT l FOOT BASE TO ROOF VITH O LAG BOLT C ' S.S. LAG SCREW WITH FLAT WASHER Z 2S' MV41K 1 EMBEDMENT IS STANDARD � Z to -1 D r r SMAPNRACK D L FOOT BASE -1 O ROOF DECKING TYP. Z SEAL PENETRATION AND D UNDER BASE WITH Z APPROPRIATE ROOF SEALANT C ROOF DECKING TYP. > r RAFTER TYP. ��IESf�VASA NA FLASHED L FOOT MOUNTING POINT F13R USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3' USING UP TO TWO LEVELING SPACERS AS SHOWN IN 'SERIES 100 RAIL LEVELING' ms wowwioR s mvwuru..w -i.� rwmn�ur..RrRu�mouc'wK G.MtPHEEfERS ISCALf I DNSPART i REV *° RAPIER G.MCPHEETERS DATE 120111 PEN-DOM PEN DETAIL 01 FLASHED L FOOT E PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 390OW DC,360OW AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK)DIMENSIONS: 2. (15)REC SOLAR: REC260PE(BLK)MODULES WITH (1) MAGNETIC TRUE ' ��r ' 65.55"x 39.02"x 1.5" PAGE POWER-ONE: PVI-3.6-OUTD-S-US-A(240V)INVERTER. ARRAY PITCH ORIENTATION ORIENTATION Qac 2. PORTRAIT:CLAMP 8.2"-16.4"FROM EDGE # DESCRIPTION STORY3. SINGLE 3. LANDSCAPE:CLAMP 0"-9.8"FROM EDGE TIION FOREMAN TO CONFIRM FINAL CONDUIT AR-01 20° 256° 270° r , 4. CONST UC RACKING NOTES: PV-01 SITE PLAN &MECHANICAL RUN PLACEMENT WITH CUSTOMER. A 1. SNAPNRACK SERIES 100 OR S100 UL LISTED; 5. ROOF STRUCTURE:2X4 PRE-FABRICATED TRUSSESPV-02 ELECTRICAL 24"OC. FLUSH MOUNT L-FOOT.SEE PEN D01. 6. 24" #:36615020 2. 8'-0"MAX RAIL SPAN i n 3. 2'-8"MAX RAIL END OVERHANG 7. CONTACT: PATRICIA LOWERS, (408)257-2294 r 4. LAG SCREWS:5/16"X 4.0":2.5"MIN EMBEDMENT 8. DESIGN CRITERIA: = 5. RAFTER AND PENETRATION LOCATIONS TO BE 8.1. SYSTEM WEIGHT: 3LBS/SQFT. "''"`''''` DETERMINED IN THE FIELD. 8.2. EFFECTIVE WIND SPEED: 110 MPH 3-SEC GUST. o5;,sport rd 6. INSTALLER TO VERIFY RAFTER SIZE,SPACING, AND UNSUPPORTED SPANS AND NOTIFY E.O.R OF ANY DISCREPANCIES BEFORE PROCEEDING. INSTALLERS TO STAGGER PENETRATIONS. SITE PLAN-SCALE=1/16"=1' ® D1 -AR-01 -SCALE: 1/8"=1'-0" FIRE SETBACKS(3' �,P) (N)INVERTER WITH . ARRAY WILL BE VISIBLE FROM ADJACENT PROPERTIES. INTEGRATED DC (N)ARRAY AR-01 DISCONNECT }-4'-2'- 26'-4" 23'-2" - { 230.9 sq.ft. (N)AC DISCONNECT I (EXTERIOR WALL) PL PLPL (N)SUN RUN METER I (EXTERIOR WALL) 10' (E)SERVICE ENTRANCE G] &MAIN PANEL (EXTERIOR WALL) 8'TYP 42' 0— 23' 4 a I X-5" e I o 1 v RAILS } RP)SETBACKS(3' FOOTINGS -, 0 a a W O 4 D2-ELEVATION-SCALE: NTS da d4a � 10'-11" 3'-7"306■ � v o_ 1 4' rsol? I PL PL PL-N PL Qj (E)RESIDENCE cap SOLAR MODULE ` Y (E)DRIVEWAY SNAPNRACK RACKING - 16' (E)PROPERTY LINE 2"x vAl 1 ' PARTIAL ROOF SECTION SCALE: NTS ?414 SUNRL �y CA CL z3ooLw Rato,tmlTF,sw JOSE.7445.3CA 1 S. KLEIN SUNRUN PROJECT NUMBER: PATRICIA LOWERS RESIDENCE SITE PLAN sunrun CA CL#750184 PHOAX40&�463062 DESIGNER: :A FAX DRAFTER: DI PATRICIA LOWERS(102R-478LOWE) 1478 PRIMROSE WAY,CUPERTINO CA 95014 5255 MECHANICAL PV-01 11/24/2014 LINE DIAGRAM: 120/240 VAC SYSTEM CHARACTERISTICS-INVERTER 1 SINGLE PHASE SERVICE SYSTEM SIZE 3900 W O METER#: SYSTEM OPEN CIRCUIT VOLTAGE 325 V M PGE 1005359673 UTILITY SYSTEM OPERATING VOLTAGE 245.6 V GRID MAX ALLOWABLE DC VOLTAGE 600 V b EXISTING 100A SYSTEM OPERATING CURRENT 17 A C MAIN BREAKER (CENTER FED) SYSTEM SHORT CIRCUIT CURRENT 22.53 A TLABEL PLACEMENT:AC BREAKER (INSIDE OR FRONT OF PANEL) EXISTING PV MODULES 100A MAIN LOCKABLE POWER-ONE: JUNCTION BOX PANEL SUN RUN BLADE TYPE PVI-3.6-OUTD-S-US-A(240V) MIN RATED NEMA3R / REC SOLAR: REC260PE(BLK) FACILITY METER AC DISCONNECT (7)MODULES LOADS 3600 WATT INVERTER (OR EQUIVALENT) 1 �\ �3 rC3 rt—3 2./� o---e% (1)STRING OF(7)MODULES �1 0--- O o � _— vPV MODULES FACIUTY / REC SOLAR: REC260PE(BLK) 20A PV CaRO1ND 250V METER SOCKET SQUARE D DUAL MPPT TRACKERS STRING +��� (8)MODULES . THE LETTERING SHALL BE RED PLASTIC & BREAKER AS 125A CONTINUOUS& DU221RB COMBINER&LOAD RATED DC (1)STRING OF(8)MODULES LETTERING SHALL BE ENGRAVED 1/2"HIGH AND FAR FROM MAIN 240V METER 3R, 30A DISCONNECT AND AFCI WILL BE WHITE LETTERING ON GREEN OR RED BREAKER AS 200A, FORM 2S 120/240VAC PLASTIC. POSSIBLE NOTES TO INSTALLER: SIGNAGE: 1. 302 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. CONDUIT SCHEDULE WARNING 2. ADD 20 AMP PV BREAKER TO MAIN PANEL. # CONDUIT CONDUCTOR NEUTRAL GROUND WARNING-Dual Power Sou—,nd source is ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH UNE AND 1 NONE (4) 10 AWG PV WIRE NONE (1)10 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED WARNING IN THE OPEN POSITION 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)8 AWG THHNITHWN-2 �^^ � DC VOLTAGE IS ALWAYS PRESENT LABEL PLACEMENT:AC DISCONNECT, WHEN SOLAR MODULES r�3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TOSUNUGHT WARNING-El-Aft Bh;r Hazard LABEL PLACEMENT: r10 °Bf mrvLoma°pe"5~s10s r DC DISCONNECTS Comas out o'Imtl earvlter for aasl"unce GROUNDING DETAIL LABEL PLACEMENT:AC DISCONNECT, WARNING COMBINER BOX,INVERTER CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD ELECTRICAL NOTES: SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS LABEL PLACEMENT: 1. PHOTOVOLTAIC SYSTEM WILL CONDUIT,JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED COMPLY WITH 2011 NEC. 2. ELECTRICAL SYSTEM GROUNDING PHOTOVOLTAIC POWER j LABEL PLACEMENT: WILL COMPLY WITH 2011 NEC. LABEL SOURCE INVERTER 3. PHOTOVOLTAIC SYSTEM IS #laza ssLOCK NUT CONDUR,JUNCTIONBOXES WARNING UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE *Lm D0�6oOfn�GYJC�64 ELEDO OT TOUCH *Lm INVERTER.SYSTEM COMPLIES ALLLABEL DISCOPLACEMNNECTS LOAD SIDES MATERMINALS ONY BEE ERGITH LINE IZZED ALL DISCONNECTS WITH 690.35. MODULE CHARACTERISTICS IN THE 010 S3 EXTERNAL TOOTH MODULE FRAME OR RAIL OPEN POSITION 4. MODULES CONFORM TO AND ARE LOCK(STAR)WASHER LABEL PLACEMENT: LISTED UNDER UL 1703. REC SOLAR: REC260PE(BLK) 260 W V AC DISCONNECTS 5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V #10-24X3r4'SSHCS DOLT 10 AWG BARE CU WIRE WARNING LISTED UNDER UL 1741. 6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 40.6 V ss SET SCREW INCLUDED ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS SIZED FOR DERATED CURRENT. LAY-IN LUG TERMINAL PHOTOVOLTAIC SYSTEM ARE 9.01 AMPS MODULE SHORT MAX POWER VOLTAGE 30.7 V rn UUDDUUALRATED UNGROUNDED AND MAY BE ENERGIZED LATED CU) CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A O ® LABEL PLACEMENT: 14.07 AMPS DERATED SHORT JUNCTION BOXES,COMBINER BOXES,CIRCUIT CIRCUIT(690.8(a)&690.8 SHORT CIRCUIT CURRENT(690.8(A)(1)) 11.26 A DISCONNECTS (b))' NOTE:REMOVAL OF PAINT IS NOT NEEDED PER UL 1703.11.3 AND 1703.11.4 Fc RUN,INC. MWZANKERROAD,UNITF.SANJOSE.CA95131NER: REV:A sunrun L7�1� PHONE 40&7463062 S.KLEIN SUNRUN PROJECT NUMBER: PATRICIA LOWERS RESIDENCE FAX PATRICIA LOWERS(102R-478LOWE) 1478 PRIMROSE WAY, CUPERTINO CA 95014 5255 ELECTRICAL PV-02 11/24/2014 .19 ER: DI THREE LINE DIAGRAM: 120/240 VAC SINGLE PHASE SERVICE OMETER#: M PGE 1005359673 UTILITY GRID 1 EXISTING 100A ( MAIN BREAKER \p (CENTER FED) EXISTING JUNCTION BOX MIN RATED NEMA3R PV MODULES 100A MAIN LOCKABLE POWER-ONE: (OR EQUIVALENT) REC SOLAR: REC260PE(BLK) FACILITY PANEL 3 SUN RUN BLADE TYPE PVI-3.6-OUTD-S-US-A(240V) 2 �j/� 7 DULES LOADS METER 3 AC DISCONNECT 3 3600 WATT INVERTER ±T/ (1)STORING OF(7)MODULES _ G- � O L� tee% PV MODULES FAGUTY / REC SOLAR: REC260PE(BLK) 20A PV ` O1ND 250V METER SOCKET SQUARED DUAL MPPT TRACKERS STRING + � (8)MODULES BREAKER AS 125A CONTINUOUS& DU221RB COMBINER&LOAD RATED DC0 (1)STRING OF(8 MODULES FAR FROM MAIN 240V METER 3R, 30A DISCONNECT AND AFCI BREAKER AS 200A, FORM 2S 120/240VAC POSSIBLE NOTES TO INSTALLER: CONDUIT SCHEDULE 1. 302 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 20 AMP PV BREAKER TO MAIN PANEL. # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4) 10 AWG PV WIRE NONE (1) 10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)8 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 SUNRUN,INC. nWZANKERROAD.UNIT F,SANJOSE.CA95131 DESIGNER: sunrun CA CL#750184 PHONE4W7463062 S. KLEIN SUNRUN PROJECT NUMBER: PATRICIA LOWERS RESIDENCE THREE LINE REV:A FAX 408-8944)2N DRAFTER: DI PATRICIA LOWERS(102R478LOWE) 1478 PRIMROSE WAY, CUPERTINO CA 95014 5255 DIAGRAM PV-03 11/24/2014