Loading...
14030005 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 7964 WOODLARK WAY CONTRACTOR:STONE CITY CORP. PERMIT NO: 14030005 OWNER'S NAME: CHEN WU AND YIJIE HUO 2830 OLIVE AVE DATE ISSUED:05/14/2014 OWNER'S PHONE: 6507146338 FREMONT,CA 94539 PHONE NO:(510)219-3632 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL F] COMMERCIAL 0 CONSTRUCT ONE STORY ADDITIONS(1114 SQ FT); License Classj Lie. FRONT PORCH(31 SQ FT); INTERIOR REMODEL(749 SQ FT); Contractor /ly1�C�Ty/`I -� Data /St,�'�O�� ELECTRICAL PANEL UPGRADE(200AMPS);RE-ROOF I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$200000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36204040.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180�AYS,OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, _ costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: `® �); Date: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. � RE-ROOFS: SignatureDate / `1 4)1 All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: 0�p. Date: r U 1.9 I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records_ granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION b� COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION O� 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228•FAX(408)777-3333•building(d),cupertino.orq ❑NEW CONSTRUCTION ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS r77 6 G �f,v a APN# 362 62 -0 4 _ O (6 0 71 633, OWNER NAME �� I v PHONE E-MAIL �e Kuc — STREET ADDRESS V�(� (�(a r(c �I� CITY, STATE,ZIP Gu C r�,, Lir FAX CONTACT NAMEJud /'k PHONE E-MAIL _ a, STREET ADDRESS •1,r n Je Q Ve CITY,STATE, ZIP Fpe< FAX ❑ OWNER ❑ o 6NER-BUAAER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME &� l ; LICENSE NUMBER 915 0 f 7 5_ LICENSE TYPE BUS.LIC# r2 0 1 y COMPANY NAME /'/ 1 (,)/,12 I/ E-MAIL S Ge C" i i a Y;;C� e t M,4'� C £ FAX STREET ADDRESS J l $ C ,(e p J CITY,STATEE,ZIP �r� C l� q of >C/ PHONE(�io) L. 30 �l / ARCHITECT/ENGINEER NAME Iu ( /r LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIPqS3 j PHONE �( SS (SIC��S7`Oy3 DESCRIPTION OF WORK 11✓' ! S.l?G'e 4 i! CE,e l0 �Cr reins e1 44, EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES 7- n I USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO C3 TOTAL AREA I I` AREA `Z. Z AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA /�.G' PORCH AREA DECK AREA TOTAL DECKPORCH AREA GARAGE AREA: _((DETACH (2ATTACH #DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES BEING ADDED? NO ADDITION? ®NO PRE-APPLICATION []YES IF YES,PROVIDE COPY OF IS THE BLDG AN E]YES �.RECEI - -21nmi TOTAL VALUATION; PLANNING APDL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? [:j NO r. _ x� , Zoo ad By my signature below,I certify to each of the following: I am the property owner or autho o t on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of or is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to e er the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED 61- A"" b x� �` � PLAN,CHECKTYPE .�' RO,IriING„SL �, {_ _New SFD or Multifamily dwellings: Apply for demolition permit for OVER TIiE.COUNTEI�^ � ��d BUTlSD1NG PLAN REVIEW �+� ti existing building(s). Demolition permit is required prior to issuance of building s t a t � � ,; permit for new building. ,t xPxss PNNnvG i REViEV4yw_ _Commercial Bldgs: Provide a completed Hazardous Materials Disclosures s .stns • ilBlt oRlfsK form if any Hazardous Materials are being used as part of this project. _Copy of Planning Approval Letter or Meeting with Planning prior to +r submittal of Building Permit application. Ru1S BldgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION ADDRESS: 7964 WOODLARK WAY DATE: 03/03/2014 REVIEWED BY: MELISSA APN: 362 04 040 BP#: V03006)5— "VALUATION: 1$200,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Du lex 2nd Unit? Yes No PENTAMATION 1 R3SFDADD USE: P OTC? ®Yes GNo PERMIT TYPE: WORK FRONT& REAR ADDITION OF 1114 S.F. N FRONT PORCH 31S.F REMODEL 749 S.F. SCOPE UPGRADE PANEL TO 200AMPS, RE-ROOF 16SQ'S TO MATCH (N) ROOF TILES OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. s.f. R-3 (Custom) II-B,111-B,IV,V-B 1,145 $2,617.06 1R3PLNCK $1,760.50 IR3INSP TOTALS: 1,145 $2,617.06 $1,760.50 MECH,HOURLY 0 Yes (j) No PLUMB,HOURLY Q Yes Q No ELEC,HOURLY Q Yes Q No 7-1 Elec. Plan Check 0.0 firs $0.00 Elec. Permit Fee: 1EPERMIT Other Elec.Insp. Ej�rs $47.00 NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . These ees are based on the relimina information available and are only an estimate. Contact the Dept/or addn'l info. FEE ITEMS (Fee Resolution 11-053 Eft iil L1 FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,617.06 F-7497 s.f. Remodel, Other Suppl. PC Fee: (j) Reg. Q OT 0.0 firs $0.00 $558.00 IREMRESOTx PME Plan Check: $0.00 11,6001 s.f. Re-roof Permit Fee: $1,760.50 $256.00 IREROOFRES Suppl. Insp. Fee:Q Reg. () OT 0.0 hrs $0.00 [-2--070amps Electrical PME Unit Fee: $0.00 $47.00 IBELEC200 Services PME Permit Fee: $47.00 0 Work Without Permit? 0 Yes E) No $0.00 0 Advanced Planning; Fee: 1PLLONGR $160.30 Select a Non-Residential E) Travel Documentation Fee: ITRAVDOC $47.00 Building or Structure 0 Strop,Motion Fee: 1BSEISMICR $20.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $8.00 SUBTOTALS: 1 $4,659.86 $861.00 TOTAL FEE: $5,520.86 Revised: 01/15/2014 s CALGREEN RESIDENTIAL CHECKLIST— MANDATO(ZY"'r":` ITEMS � . l� tiO�Q COMMUNITY DEVELOPMENT DEPARTMENT-BUILDING DIVISION ­ 6 ' CUPERTINO ALBERT SALVADOR,P.E.,C.B.O., BUILDING OFFICIAL TSL 10300 TORRE AVENUE-CUPERTINO,CA 95014-3255 (408)777-3228-FAX(408)777-3333-buildinq@cuaertino.org PURPOSE: The 2013 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory-built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: Huo Addition Project Address: 7964 Woodlark Way, Cupertino, CA Project Description: Rear and Front Addition tiillII�r Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the California Green Building Standards Codes to verify and assure that all required work described herein is property planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 -Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 -Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Re uirements A4.1 PLANNING Planning and Design -Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during ❑X ❑ construction. 4.106.3 Grading and paving. The site shall be planned and developed to keep surface water away from buildings. Construction plans shall indicate how EL ❑ site grading or a drainage system will manage all surface Cut INO m PAA` ti 6 20% REViEWEL) r-(JR C(juE COMPLIANCE Page 1 of 5 Rl-ve",Je,' t3y ��i2'S-�lalG ?.¢4.doc revised 01/15/14 - • A4.2 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. A4.3 WATERAND CONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals)and fittings(faucets and showerheads)shall comply with the following: ❑ 4.303.1.3.2 Water Closets.The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank-type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead,the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be ® ❑ designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas(outside of dwellings or sleeping units)in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CalGreen_2014.doc revised 01115114 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather-based. ❑ 4.304.1.1 Controllers shall be weather-or soil moisture-based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. © ❑ ❑ 4.304.1.2 Weather-based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture-based controllers are not required to have rain sensor input. A4.4 MATERIAL Enhanced Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected © ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a ® ❑ construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building ® ❑ occupant or owner. A4.5 ENVIRONMENTAL QUALITY Fireplaces 4.503.1 General. Install only a direct-vent sealed-combustion gas or sealed ® ❑ wood-burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical equipment during construction. Duct openings and other related airX❑ ❑ distribution component openings shall be covered during construction. 4.504.2.1 Adhesives,sealants and caulks. Adhesives, sealants and caulks © ❑ shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be ❑ compliant with VOC limits. LQJ 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR Limits for ROC and other toxic ❑X ❑ compounds. Page 3 of 5 CalGreen_2014.doc revised 01/15/14 4.504.2.4 Verification. Documentation shall be provided to verify that © ❑ compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with © ❑ VOC limits. 4.504.4 Resilient flooring systems. Eighty(80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools(CHPS)Low-emitting ® ❑ Materials List or be certified under the Resilient Floor Covering Institute(RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard(MDF), and hardwood plywood used in interior finish systems shall ❑X ❑ comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary © ❑ breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building © ❑ materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the El are provided in every bathroom. Environmental Comfort 4.507.2.Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. ❑ 2. Size duct systems according to ACCA 29-D(Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALIFICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in ® ❑ the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the ® ❑ discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents,plans, specifications,builder or installer certification, inspection reports, or other methods acceptable to the enforcing ❑ agency which show substantial conformance. Implementation verification shall nX be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen_2014.doc revised 01/15/14 CALGREEN SIGNATURE DECLARATIONS Project Name: Huo Addition Project Address: 7964 Woodlark Way, Cupertino, CA Project Description: Rear and Front Addition SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1 —"Design Verification"and submit the completed checklist(Columns 1 and 2)with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Owner's Signature Ol HMO Date Owner's Name (Please Print) Design Professional's Signature Date Design Professional's Name (Please Print) Aa z, Signature of License Professional responsible for CalGreen compliance D to ` S Name of License Professional responsible for CalGreen compliance(Please Print) Phone pe Cd-7 Email Address for License Pr fessional responsible for CalGreen compliance SECTION 2 — IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3,together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance(Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of CalGreen_2014.doc revised 01/15/14 BUILDING ENERGY ANALYSIS REPORT RECEIVED PROJECT: APR 16 2014 Huo Residential Addition and Remodel 7�)64 Woodlark Way Cupertino, CA 95014 Project Designer: Stone City Co. I Report Prepared by: JNB Associates CUPERTINO Building Department MAY 0 6 2014 HDR LODE COMPLIANCE Y Job Number: 2014-03 Date: 3/27/2014 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number:4066 RunCode,201403-27716.36:12 10:2014-03 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 EnergyPro 5.1 by EnergySoft Job Number: ID:2014-03 User Number:4066 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Huo Residential Addition and Remodel ❑Multi Family ® Existing+Addition/Alteration 3/2712014 Project Address California Energy Climate Zone Total Cond.Floor Area Addition #of Stories 7964 Woodlark Way Cupertino CA Climate Zone 04 2,244 1,114 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-413 must be provided per Part 2 of 5 of this form. ❑ Yes ® No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed None 856 Existing Roof Wood Framed Attic R-11 1,130 Existing Floor Wood Framed w/Crawl Space None 1,130 Existing Wall Wood Framed R-13 119 New Door Opaque Door None 20 New Roof Wood Framed Attic R-30 1,114 New Floor Wood Framed w/Crawl Space R-19 1,114 New Wall Wood Framed R-13 813 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front(N) 18.0 0.550 0.67 none none Bug Screen Removed Left(E) 6.0 0.550 0.67 none none Bug Screen Existing Left(E) 79.0 0.390 0.37 none none Bug Screen New Rear(S) 40.0 0.550 0.67 none none Bug Screen Existing Right(W) 27.0 0.550 0.67 none none Bug Screen Existing Rear(S) 36.0 0.550 0.67 none none Bug Screen Removed Front(N) 50.0 0.390 0.37 none none Bug Screen New Rear(S) 24.0 0.390 0.37 none none Bug Screen New Right(W) 50.0 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 93%AFUE Split Air Conditioner 13.0 SEER Setback Altered HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status New FAU&A/C Ducted Ducted Attic, Ceiling Ins,vented 6.0 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number 4066 RunCode:2014-03-27716:36:12 ID:2014-03 Pa e 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name Building Type ®Single Family ❑Addition Alone Date Huo Residential Addition and Remodel ❑Multi Family ® Existing+Addition/Alteration 3/27/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Enerc YPro 5.1 by EnergySoft User Number.4066 RunCode:201403-27716:36:12 ID:2014-03 Pag e 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Huo Residential Addition and Remodel ❑Multi Family m Existing+Addition/Alteration 3/27/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 49.64 38.32 11.32 Space Cooling 29.44 19.65 9.79 Fans 10.98 10.53 0.45 Domestic Hot Water 1792 17.92 0.00 Pumps 0.00 0.00 0.00 Totals 107.99 86.42 21.57 Percent Better Than Standard: 20.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N)0 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 341 50 Fuel Available at Site: Natural Gas (E) 671 85 Raised Floor Area: 2,244 (S) 572 64 Slab on Grade Area: 0 (vv) 500 77 Average Ceiling Height: 8.5 Roof 2,244 0 Fenestration Average U-Factor: 0.43 TOTAL: 276 Average SHGC: a45 Fenestration/CFA Ratio: 12.3 is REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Associates ssociates �a Company 3127/2014 Address Name City/State/ZipCity/State/Zip Phone Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets,with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Stone City Co. Address Name City/State/Zip Phone Signed License# Date EnemvPro 5.1 by EnemySoft User Number:4066 RunCode:201403-27716:38:12 ID:2014-03 Pa- e 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Huo Residential Addition and Remodel ❑Multi Family m Existing+Addition/Alteration 3/27/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 152 0.356 None 0 90 Existing 4.3.1-A1 Existing Home Wall 150 0.356 None 0 90 Remov 4.3.1-A1 Existing Home Door 20 0.500 None 0 90 Removec 4.5.1-A4 Existing Home Wall 203 0.356 None 90 90 Existing 4.3.1-A1 Existinq Home Wall 48 0.356 None 180 90 Existing 4.3.1-A1 Existing Home Wall 221 0.356 None 270 90 Existing 4.3.1-A1 Existing Home Roof 1,130 0.079 R-11 0 0 Existing 4.2.1-A2 Existinq Home Floor 1,130 0.097 None 0 180 Existing 4.4.1-A1 Existin Home Wall 232 0.356 None 180 90 Existing 4.3.1-A1 Existing Home Wall 119 0.102 R-13 0 90 New 4.3.1-A3 New Addition Door 20 0.500 None 0 90 New 4.5.1-A4 New Addition Roof 1,114 0.031 R-30 0 0 New 4.2.1-A20 New Addition Floor 1,114 0.037 R-19 0 180 New 4.4.1-A4 New Addition Wall 383 0.102.R-13 90 90 New 4.3.1-A3 New Addition Wall 228 0.1021R-13 180 90 New 4.3.1-A3 New Addition Wall 1 202 0.102 R-13 270 90 New 4.3.1-A3 INew Addition FENESTRATION SURFACE DETAILS ID Type Area LI-Factor' SHGC Azm Status Glazing Type Location/Comments 1 Window 18.0 0.550 Default 0.67 Default 0 Removed Double Non Metal Clear Existing Home 2 Window 6.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Existing Home 3 Window 39.0 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low-E Vinyl Existing Home 4 Window 40.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear Existing Home 5 Window 27.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Existing Home 6 Window 36.0 0.550 Default 0.67 Default 180 Removed Double Non Metal Clear Existing Home 7 Window 50.0 0.390 NFRC 0.37 NFRC 0 New Milgard Classic Low-E Vinyl New Addition 8 Window 40.0 0.390 NFRC 0.37 NFRC 90 New Milgard Classic Low-E Vinyl New Addition 9 Window 24.0 0.390 NFRC 0.37 NFRC 180 New Milgard Classic Low-E Vinyl New Addition 10 Window 50.0 0.390 NFRC 0.37 NFRC 270 New Milgard Classic Low-E Vinyl New Addition (1) Ll-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC Hot Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 _Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 EnergyPro,5.1 by EnergySoft User Number 4066 RunCode:2014-03-27T16:36:12 ID:2014-03 Pe e 6 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R Project Name Building Type ®Single Family ❑Addition Alone Date Huo Residential Addition and Remodel ❑ Multi Family ® Existing+Addition/Alteration 3/27/2014 BUILDING ZONE INFORMATION Floor Area System Name Zone Name New Existing Altered Removed Volume Year Built New FAU&A/C First Floor Existing+Alterations 1,130 9,040 1964 First Floor 1,114 10,026 Totals 1,114 1,130 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status New FAU&A/C 1 Central Furnace 93%AFUE Split Air Conditioner 13.0 SEER Setback Altered pre-altered for above Central Furnace 78%AFUE Split Air Conditioner 9.0 SEER Setback HVAC DISTRIBUTION Duct Ducts System Name Heating Cooling Duct Location R-Value Tested? Status New FAU&A/C Ducted Ducted Attic, Ceiling Ins,vented 6.0 ❑ Existing pre-altered for above Ducted Ducted Attic, Ceiling Ins, vented 6.0 ❑ WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul.R- S stem Name Ot . Type Distribution Btuh al or RE Pilot Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft c O N y Pipe Pipe Insul. Control Oty. HP Plenum Outside Buried a System Name Length Diameter Thick. ❑ EnergyPro 5.1 by EnergySoft User Number:4066 RunCoda:2014-03-27716:36:12 ID:2014-03 Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date Huo Residential Addition and Remodel 3/27/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed,regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*)below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l:Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows)have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111(a). 117:Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a):Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-611 Form. §118(1):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(1)when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b):Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50 c :Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. 150(f):Air retarding wr is tested,labeled and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no areater than 2.0 emn/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113:HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve,backflow prevention,pump isolation valve and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces,household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2:First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150@2:Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150@2:Pipe insulation for steam hydronic heating systems or hot water systems>15 psi,meets the requirements of Standards Table 123-A. 150(i)3A:Insulation is protected from damage,including that due to sunlight, moisture,equipment maintenance,and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4:Solar water-heating systems and/or collectors are certified by the Solar Ratinq and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number 4066 RunCode:201403-27716:36:12 ID:2014-03 Page 8 of i i MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Huo Residential Addition and Remodel 3/27/2014 §150(m)1:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181,UL 181 A,or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tae shall be used §150(m)1: Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air.Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150(m)9: Insulation shall be protected from damage,including that due to sunlight,moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10:Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light. §114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater, or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3:Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 :Residential pool systems orequipment meet the pump sizing,flow ratepiping,filters,and valve requirements of§150 . Residential Lighting Measures: §150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by§150(k)2. 150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5:Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a medium screw-base socket. 150(k)6:Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer,energy management system(EMCS),or a multi-scene programmable control system;and all permanently installed luminaries in garages, laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9:Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number.4066 RunCode:201403-27Ti6:36:12 ID:2014-03 Pege 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Huo Residential Addition and Remodel 3/27/2014 §150(k)l0:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms, closets,and utility rooms shall be high efficacy luimnaires.EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119.EXCEPTION 2:Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)l2:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3:Luminaires providing outdoor lighting,including lighting for private patios in low-rise residential buildings with four or more dwelling units,entrances,balconies,and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1:Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system(EMCS)not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptionl to§150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be hiah efficacy luminaires. §150(k)l4:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket,and consume no more than five watts of power as determined according to§130(d). §150(k)l 5:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132,134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130 131, 134,and 146. §150(k)l6:Permanently installed lighting in the enclosed,non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number:4066 RunCode:2014-03-27T16:36:12 ID:2014-03 Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Huo Residential Addition and Remodel 3/27/2014 System Name Floor Area New FAU &A/C 2,244 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG.PEAK Heating System CFM Sensible Latent CFM Sensible Output perSystem 94,000 Total Room Loads 1,409 22,711 1,1321 497 40,457 Total Output Btuh 94,000 Return Vented Lighting 0 Output Btuh/ ft 41.9 Return Air Ducts 1,030 2,247 Cooling System Return Fan 0 0 Output per S tem 23,700 Ventilation 0 0 0 0 0 Total Output Stuh 23,700 Supply Fan 0 0 Total Output ons 2.0 Supply Air Ducts 1,030 2,247 Total Output Btuh/s ft 10.6 Total Output ft/Ton 1,136.2 TOTAL SYSTEM LOAD 24,771 1,132 44,951 Air System CFM per S tem 1,100 HVAC EQUIPMENT SELECTION Airflow(cfm) 1,100 Carrier 58MTB100-16 CNP 38HD 2.5T 19,793 3,995 94,000 Airtlow cfm/s ft 0.49 Airflow cfm/Ton 557.0 Outside Air °k 0.0% Total Adjusted System Output 19,793 3,9951 1 94,000 Outside Air cfm/ ft 0.00 (Adjusted for Peak Design conditions) Note:values above given at ARI conditions TIME OF SYSTEM PEAK Aug 3 PM F Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 281F 681F 68 OF 1471F Outside Air 0 cfrn Supply Fan Heating Coil 1461F 1,100 cfm ROOMgl 68 OF 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 88/68 IF 79/65 OF 79/65 OF 62/59 OF 77-1 5� Outside Air Ar A 0 cfin Supply Fan Cooling Coil 63/60 OF 1,100 cfrn49.8 /o ROOM ., ,~ 79/65 OF 78/65 OF I EnergyPro 5.1 by EnergySoff User Number.'4066 RunCode:201403-27716:36:12 ID:201403 Page 11 of 11