Loading...
14090149 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20375 SILVERADO AVE CONTRACTOR:SOLARCITY PERMIT NO: 14090149 OWNER'S NAME: SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED ONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL E] p I INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS(2 License Class Date Q ,2 1 1_I i I hereby affi t I am license the provisions of Chapter 9 REVISION#]-INSTALL SUB PANEL 125 AMP-1SSD 10/22/2014 (commenci rth Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$4500 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36939011.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct, l agree to comply with ail city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments. costs,and expenses which may accrue gainst said City in consequence of the granting of this permit. Add'i nail , e applicant understands and will comply Issued by: Date: with all non-point atigf' per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date t c 2 1 All roofs shall be inspected prior to any roofing material being installed. if a roof is t installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equip t or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Are Air ality Management District I performance of the work for which this permit is issued. will maintain compliance ^Cuperpal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code, I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Leader's Address I certify that I have read this application and state that the above information is correct. l agree to comply,with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnity and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333•building(Dcupertino.orq CUPERTINO PROJECT ADDRESS 2-o `3%5 4�1/ A; I U�.rG . L. APN# OWNER NAME STREET ADDRESS �� Q i 1"C� b ✓�VC' CITY, STATE,ZIP O � FAX CONTACT NAME Cl1l clr\Y►'1 c�Y c'\ PHONE E-MAIL 1©C►` 0.VCti1Iv\CIYc C $' 1r1 SSG'- C94 STREET ADDRESS 3 ry n5te_ri cl �'�G� CITY,STATE, ZIPc t 1 C © FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# molar �i g�8to y C o COMPANY NAME C)o ia� C E-MAIL GV j I Fill C �,. STREET ADDRESS I I CITY,STATE, I i4 o 6s0- ARCHITECT/ENGINEER NAME 1 C� LICENSE NUMi+BER BUS.LIC 4 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF M SFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO ❑ SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UN1T& KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: /° DESCRIPTION OF WORK _ I � la e1 a 1 ( r✓\Gl i Y k_— Dokn RECEIVE - - By my signature below,I certify to each of the following: I am theerty caner or authorized agent to act on the -owner's b�fiaTf. I have read this application and the information I have provided is correct. I have r the cription of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I author' e re sentatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: I Date: SUPPLEMENTALPrORMATION REQUIRED OFFICE USE ONLY w ❑ OVER-THE-COUNTER- a F ❑ EXPRESS U x ❑ STANDARD - U a ❑ LARGE- . a ❑ MAJOR PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20375 SILVERADO AVE CONTRACTOR:SOLARCITY PERMIT NO: 14090149 OWNER'S NAME: SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS(2 License Class C)- 0 Lic.# d KW) Contractor _��/�° Date aq I hereby affix at I am licensed under the provisions of Chapter 9 (commenci with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$4500 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36939011.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES LEAVORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 1 YS OF P + IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DA FROM LAST CALLED INSPE TION. indemnify and keep harmless the City of Cupertino against liabilities,judgments. costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: ` with all non-point source re? e of s per the Cupertino Municipal Code,Section 9.18. ;. s' RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District performance of the work for which this permit is issued. will maintain compliance with the Cuperti o unicipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 255 233,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: ( Date: Ll� permit is issued. Ll I certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,l CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes,(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with al I non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408)777-3228•FAX(408)777-3333•buildinq(bqupertino.prg 4 (� 1,4 PROJECT ADDRESS20375 Silverado Ave. :1APN tk 9 O OWNERNAME E-MAIL --[STREET ADDRESs20375 Silverado Ave. CITY, STATE,ZIP Cupertino,CA,95014 FAX CONTACT NAME Marjan Javanmard PHONE 650.477.6430 EMAIL mjavanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR 9 CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER TENANT CONTRACTOR NAME SoIarCity Corporation LICENSE NUMBER 888104 LICENSE TYPE C10 BUS.LIC 4288 COMPANY NAME SoIarCity Corporation E-MAIL mjavanmard@solarcity.COM FAX CC77 CC.77 STREET ADDRESS 391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ NO ❑SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FORSOLARPANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: 4'500.00 DESCRIPTION OF WORK `F J Installation (8) rooftop flush mounted solar panel (2) kW RECEIVEDBYE By my signature below,I certify to each of the following: I amt property owner or authorized agent to act on the property owner's behalf. have read t s application and the information I have provided is correct. I hav ead e Description of Work and verify it is accurate. I agree to comply ith all ap le local ordinances and state laws relating to building construction. I dri epresentatives of Cupertino to enter the above-identified prope r i Ion purposes. Signature of Applicant/Agent: Date: L SUPPLEMENT FORMATION REQUIRED OFFICE USE ONLY prW ❑ OVER-THE-COUNTER �^ ❑ EXPRESS x ❑ STANDARD U QZ ❑ LARGE .7 0. ❑ MAJOR PVApp_2011.doc revised 03,116/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 20375 silverado ave DATE: 09/24/2014 REVIEWED BY: Mendez APN: BP#: `VALUATION: 1$4,500 PERMIT TYPE: Building Permit PLAN CHECK YPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS (2kffl SCOPE Li NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District, etc. . Theseees are based on the preliminary information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS jFee Resonation 11-053 Ef-' 7%1-'13� FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: 0 Reg. Q OT 1 0.0 1 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. Q OT0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 T_T_ 0 Work Without Permit? 0 Yes (F) No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential Q Building or Structure A Strong Motion Fee: IBSEISMICR $0.59 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $1.59 $236.00 TOTAL FEE: $237.59 Revised: 08/20/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE PLOT PLANS EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY E+' ED �� (E) EXISTING PHASE AND SYSTEM PER ART, 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING p~AW FSB Fire Set-Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL �G D�P1, GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER D1?£ I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC OFFICE COPY �"�" �`-� -- Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN �1T kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY `.tUNITY DEVELOPMENT DF LBW LOAD BEARING WALL UL LISTING. BUILDING DIVISION - CU` MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE APPROVED (N) NEW UL-LISTED LOCATION PROVIDED BY THE ser of plans and specifications N1. = NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING to � r -instruction. It is un NTS NOT TO SCALE HARDWARE. - g CUPERTf,V0 �� or alterations on san , OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE - _� -- :! PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND r� tn( ;approval from t ,a Suddinq Der.,jr+, enf POI POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. n.: plan and speci r r PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR or I be an app' SEP 2 4 2014 SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & any City Ord \ REVIEWED t=OR r SS STAINLESS STEEL 690.47. _, , _ - _— C,.JIJE C;CJ[v!pLI; F� STC STANDARD TESTING CONDITIONS _ ' CE 9 - - Reviewed sy. J � TYP TYPICAL r` UPS UNINTERRUPTIBLE POWER SUPPLY r — v� V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET � PV2 SITE PLAN PV3 STRUCTURAL VIEWS ~ PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM P,'. Cutsheets Attached CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A C-10 UL-LISTED POWER-CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. • • 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 MODULE GROUNDING METHOD: ZEP SOLAR CALIFORNIA BUILDING CODE AND THE 2013 ° AHJ: Cupertino CALIFORNIA RESIDENTIAL CODE. ! REV BY DATE COMMENTS 5. ALL ELECTRICAL WORK SHALL COMPLY WITH � NEVA NAME DATE COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. UTILITY: Pacific Gas and Electric Company JB-9503249 0 0 PREMSE oma: 'DESCRIPTION: DESIGN- CONTAINED CONFIDENTIAL S — THE INFORMATION USED HEREIN a6 NUMBERCHUNG, BETTY CHUNG RESIDENCE ChM' CONTAINED SHALL NOT E USED FOR THE Jonathan Rivera ;i�SolarCity. BENEFIT OF ANYONE EXCEPT SOLARaTY INC., MOUNTING SYSTEM: �h NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY J PART To OTHERS OUTSIDE THE RECIPIENT'S MODULES: C U P E R TI N 0 C A 9 5014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleaNew Way THE SALE AND USE OF THE RESPECTIVE (8) CANADIAN SOLAR # CS6P-250PX PAGE NAYS SHEET: NEW DATE Son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) on MaF:(650)638-1029 PERMISSION of soLARCITY INC. ABB# PVI-3.0—OUTD—S—US—Z—A 4086662802 COVER SHEET PV 1 9/19/2014 (888)—SOI.—CITY(765-2489)www.solarcity.com PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH:90 ARRAY AZIMUTH:90 MATERIAL:Comp Shingle STORY: 1 Story PITCH: 22 ARRAY PITCH:22 MP2 AZIMUTH:180 ARRAY AZIMUTH: 180 MATERIAL:Comp Shingle STORY: 1 Story Un-Locked Gated N� s LEGEND Inv ZT/S ' Fire y" 0 (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS O E) G �6dc\� ® DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS oc e a e B O DC JUNCTION/COMBINER BOX & LABELS n CUPERTi Suilding Departn DISTRIBUTION PANEL & LABELS (E) DRIVEWAY ry � �: Ec LOAD CENTER & WARNING LABELS Front Of House VIEV�'FG AOR C-(-C-C-(-011; � COMPLI;� O DEDICATED PV SYSTEM METER 20375 Silverado Ave kue lev,rec Sy �T STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L_'J TOTAL ARRAY AREA (SF): 141 SITE PLAN NScale: 1/8" = 1' TOTAL ROOF AREA (SF): 1812 w E TOTAL ARRAY AREA IS a 7,8 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA S CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER J B-9503249 00 PREMISE OWUL- I>ES�PTIDN: DESIGN: CONTAINED SHALL NOT BE USED FOR THE CHUNG, BETTY CHUNG RESIDENCE Jonathan Rivera �1;SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: w.,; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION NTH � 3055 pearvier Wuy THE SALE AND USE OF THE RESPECTIVE (8) CANADIAN SOLAR # CS6P-250PX SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME: SHEET: REV: DATE Son T:(650)638 Mateo,028 F:(650)638-1029 PERMISSION of SOLARCITY INC. 4086662802 PV 2 9/19/2014 ) ABB PVI-3.0—OUTD—S—US—Z—A SITE PLAN (BW)-SOL-CITY(�6�-2+� .w..scN�cnycom S1 (E) 2x4 (E) 2x6 '-10" 4'-8" 1 2 (E) LBW (E) LBW SIDE VIEW OF MP2 NTS A M P2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 7211 2411 PORTRAIT 48" 20" RAFTER 2x4 @ 24 OC ROOF AZI 180 PITCH 22 STORIES: 1 ARRAY AZI 180 PITCH 22 C.I. 2x6 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT CUPERTINO ZEP ARRAY SKIRT (6) HOLE. Buil * C)Ao-i�ent (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING C (3) (3) INSERT FLASHING. op. - E COMPLIANCE (E) COMP. SHINGLE (4) PLACE MOUNT. `7G`�' (1) (E) ROOF DECKING V (2) (5) INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER 1 STANDOFF CONADENTIAL - THE INFORMATION HEREINJGB NUMBER I PREMISE OWNER DESCRIPDON: DESIGN CONTAINED SHALL NOT BE USED FOR THE U B-9503249 00 CHUNG, BETTY CHIiNG RESIDENCE Jonathan Rivera SolarCity. BENEFlT OF ANYONE EXCEPT SOl1+RGTY INC., MOUNTING SYSTEM -,,� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY ►�� • PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: �' C U P E R TI N 0 C A 95014 �--� ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Griew Way THE SALE AND USE OF THE RESPECTIVE W (8) CANADIAN SOLAR # CS6P-250PX PAGE NAME: SHEET: �' DAA' T:(sso)sass-Mio s'C94402 3a-low SOLARGTY EQUIPMENT.SOLNT, WITHOUT THE WRI11T?I INVERTER PERMISSION OF souRGTY INC. ABB PVI-3.0—OUTD—S—US—Z—A 4086662802 STRUCTURAL VIEWS PV 3 9/19/2014 (88e)—SOL—CITY(765-2489)www.soIadtxcom UPLIFT CALCULATIONS 07.27,2014 ►,;SO�c`��Clt�/. SleekMountTM PV System VwOw*37.7 Structural Desian Software II _ t Roof 22° PV SyS�n.Module C>iierlcagon Land,eape an PortraR PV Module WIdtl1 39' do(f(Attasfi�n _.- CMP mow* TWIN C Cii'01111d$I10r[Load � 0.0�� J/ISCEIG 7-1 PY Modulen 7.4-1 WM9d t?esi � ASM7-109 Sas1c Wind Speed _-. _V LMO n" 26 5!A ROOF Qbl-e/Wp ROOF AO s7MNd WecUw Wind Area(l NOdule A 17.63f 18C1509.7.1 time E>�obure Kz 095 30.3-1 1fYlnd bBedlonalny Fat1oT Kd. _ _._0.83 ' SecllOn 26:6=1 _.� .._. r gh-G.W2%OW)(/�.� (".2) C U PERTI NO w ► � 9 Building Department Pt Codndot -0.88 Coelcavo- 2 4 2014 >r woo - 60Df COMPLIANCE tpct ABOvvable Statrdolf Spdny7r 39' - -.� ed. load 3,* of Statiddf T-WOW 500 bs Spadn4 ,Por6alt - 4W7. W-PV Ind 65" r rI311NdolF T-abw 51101114 CONFIDENTIAL- THE NFORMATION HERM doe NW�ER g-9503 49 Pr�sE OWM nat oESIM •+wT CHUNG, BETTY CHUNG RESIDENCE Jonathon.Rivera �> � • eENEFIt OF ANYONE EXCEPT SOLARCITY NC., YDININD sTsT[k �i y NOR SHALL IT BE DlsaM N*W OR IN Com Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY PART TO OTHERS OUTME THE RECIPIENTS CU P E R TI N 0 CA 95014 ORGANIZATION, EXCEPT N CONNECTION wnFi , 3os6 pearl THE SALE AND USE OF THE RESPECTIVE 8 CANADIAN SOLAR CS6P-250PX PAGE NwE DATE' ,,,CA Way SOLARpTY EQUIPMENT. WITHOUT THE NPoTiENKAMM L("638-1028 F.("638-1029 �'I�10N of S0LA1�'TM"� ABB PVI-3.0-0UTD—S—US—Z—A 4086662802 UPLIFT CALCULATIONS PV 4 9/19/2014 (Bes�sa-cm(ABs-2�e9).... Ix GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: Murray Inv 1: DC Ungrounded INV 1 —(1)ABB# PVI-3.0—OUTD—S—US—Z—A —(8)CANADIAN SOLAR # CS6P-250PX CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006724929 FCI inverter; Zigbee 3000W, 240V, 96% PV Module; 250W,' 229.6W PTC, 40mm, Black Frame, MC4, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37,2 Vpmax: 30.1 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER Inverter 1 PAR 200A/2P 3 ABB PVI-3.0—OUTD—S—US—Z—A (E) LOADS • Ll zauv SolarCity Lz 2OA/2P " 2 A 1 EGC/ oc. Dc• VStart = DEFAULT A --————————————————————————————————————————————— — GEC ---� DG I I DLJ I MP 1: 1x8 8 I GND EGC — EGC————————————— ----� I I I N I I EGCIGEC —j Z Z c.7 --- GEC --� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I L,ui!oln � �rtment -P 2 14 �EVIEwE "'OiAPL' INCtw Voc* = MAX VOC AT MIN TEMP Ol (1)MURRAY/MP220 PV BACKFEED BREAKER /�� A �4 STRING JUNCTION BOX D� Breaker, 20A/2P, 2 Spaces Jy Zx2 S GS, UNFUD, GfZOUNDE k)Ground Rod; 5/8` x 8', Copper 1 AWG #10, THWN-2, Black (I)AWG /10, THWN-2, Black Voc* =330.99VDC Isc =8.87 ADC (2)AWG#10, PV WIRE, Black Voc* =330.99VDC Isc =8.87 ADC O 141—(1)AWG #10, THWN-2, Red O (1)AWG #10, THWN-2, Red Vmp =240.8 VDC Imp=8.3 ADC O (1)AWG j10, Solid Bare Copper EGC Vmp =240.8 VDC Imp=8.3 ADC LCL(1)AWG /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC LLL���LLL(1)AWG /10, THWN-2,.Green. . EGC. . . -0)Conduit_Kit;.3/4'_EMT . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 AWG #8, T11WN72,.green. . . P9P/qEC.7(QP00dU.it.Kit;.3/4'.FAIT. . , . .. . . . . CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-9503249 0 0 PRMSE OWNER. T DESCRIPTION. DESIGN. CONTAINED SHALL NOT BE USED FOR THE CHUNG, 8tT I i' CHUNG RESIDENCE Jonathan Rivera _�' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:- NOR YSTEM: .;,So�arCity. �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY Wi PART OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTIN0 CA 95014 ORGANIZIZ ATION, EXCEPT IN CONNECTION WITH ' THE SALE AND USE OF THE RESPECTIVE (8) CANADIAN SOLAR # CS6P-250PX 3055 Clearview Way SOLARCPAGE NAYS SHEET: REV DATE Son Mateo,CA 94402 PERMISSION EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERYlSSION of solsRaTY INC. ABB PVI-3.0-OUTD-S-US-Z-A 4086662802 THREE LINE DIAGRAM PV 5 9/19/2014 (888)-SOL-CITY(765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE D GE N) D R ane er: 1: grou NV 1 — )ABB# -3.0- -S- -Z-A EL A (8)CA DIAN S R CS -250P fAl PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006724929 FCI Inverter; Zigbee 3000W, 240V, 96% PV Module; 250W#229.6W PTC, 40mm, Black Frame, MC4, ZEP Enabled C-10 Overhead Service Entrance INV 2 Voc: 37,2 Vpmax: 30.1 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER N 125A MAIN SERVICE PANEL N 10OA/2P MAIN CIRCUIT BREAKER Inverter 1 PAR 10OA/2P 3 ABB PVI-3.0-OUTD-S-US-Z-A (E) LOADS taov SolarCity L1 • Lz 20A/2P EGG DC. Dc. VStart = DEFAULT A ----------------------------------------------- — GEC ---LL... Dc DC- MP 2: 1x8 8 I EGC--------------------------- T1NO--------� I I 3Uildinq Derrertnent N f EGGGEC Z Z c� REVIEWED (--;QOE COMPLIANCE GEC_ ro 120/240v --- - -- Reviewed By: SINGLE PHASE UTILITY SERVICE I I I I toc* = MAX VOC AT MIN TEMP OI (1)Ground Rod; 5/8' x 8', Copper /� A y /-� (1)S21xa2 SiR GS,SUNIFNUSEDNGROUNDmX DC 1 AWG 110, THWN-2, Black (I)AWG 110, THWN-2, Black Voc* =330.99VDC Isc =8.87 ADC 2)AWG#10, PV WIRE, Black Voc* =330.99VDC Isc =8.87 AD O�(1)AWG f10, THWN-2, Red O (1)AWG /10, THWN-2, Red Vmp =240.8 VDC Imp=8.3 ADC O (1)AWG#10, Solid Bore Copper EGC Vmp =240.8 VDC Imp=8.3 ADC ��LLLL(1)AWG /10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC (1)AWG /1.0, HWM-2, Green EGC. , . .-(1)Conduit.Kit;.3/4' EMT . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-(1)AWP 18,.THWN7?,.9reen. . . EGC/GEC.-(i)Conduit.Klt;.3/47.EMT. . . . . . . . . . J B-9 503 249 00 PREMISE OTHER: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER CHUNG RESIDENCE \\,4�SolarCit e CONTAINED SHALL NOT BE USED FOR THE CHUNG, BETTY � Jonathan Rivera � � NOR SH OF ANYONE EXCEPT SOLWHOLE INC., MOUNTING S151E]A: �,,, Y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 20375 SILVERADO AVE 2 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (8) CANADIAN SOLAR # CS6P-250PX 3055 Clearvier Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET. . REV: DATE San Mateo, CA 94402 P29 ERMISSION OF SOLARCITY INC. INVERTER: 4086662802 f V 5 0 10/2/2014 (888)-SOL-CITY 650)638-1028 F:(650) ABB PVI-3.0-OUTD-S-US-Z-A THREE LINE DIAGRAM WARNING:PHOTOVOLTAIC POWER SOURCE PV SYSTEM WARNING Lab I Location: Label Location: Label Location:D Per Code: DISCONNECT FOR Per ELECTRIC SHOCK HAZARD Code: CRC R331.2UTILITY OPERATION THE DC CONDUCTORS OF THIS CEC 6' Label Location: PHOTOVOLTAIC SYSTEM ARETO BE USED WHEN PHOTOVOLTAIC DC MAY BOINVEENERGIZED • DISCONNECTTERIS Code: UNGROUNDED CEC .•0 Label • • WARNING Code:Per ELECTRIC SHOCK HAZARD Label • • CEC •.� DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_APer Code: LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER- CEC 690.53 IN THE OPEN POSITION POINT VOLTAGE(Vmp)_V MAXIMUM SYSTEM_V VOLTAGE(Voc} SHORT-CIRCUIT_ CURRENT(Isc) A Label • • WARNING Per Code: CEC 705.12.D.7 INVERTER OUTPUT CONNECTION Label Location: DO NOT RELOCATE WARNINGB THIS OVERCURRENT Per Code:dDEVICE ELECTRICAL SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• - • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTIONPer Code: SOLAR MODULES ARE WARNING: ELECTRIC SHOCK 690.54; 690.17 EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDECUPERTINO MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE _ nt Label Location: DE-ENERGIZE BOTH SOURCE WARNING Per AND A AIN BREAKER. PV POWER SOURCE Code: MAXIMUM AC A ELECTRIC SHOCK HAZARD CEC690.5(C) OPERATING CURRENT _ IF A GROUND FAULT IS INDICATEDMAXIMUM AC NORMALLY GROUNDED OPERATING VOLTAGE _ V CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label • • Label; Location: CAUTION (POI). Disconnect PHOTOVOLTAIC AC (POI) PHOTOVOLTAIC SYSTEM DISCONNECTCode: CIRCUIT ISBACKFED 690.64.B.4Conduit CEC •.014.C.2 (CB): Combiner :• Distribution Disconnect Interior • • Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM Ac _ A '• CAUTION '• •'• Center OPERATING CURRENT Per ••-: Per Code MAXIMUM ACCEC 690.54 SECOND SOURCE ISCEC 705.12.D.7 OPERATING VOLTAGE _ V PHOTOVOLTAIC SYSTEM OI): Point of • • SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleT^modules aesthetics while minimizing roof disruption and a Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and • Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition listed to UL 2703 of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 A Seal pilot hole with roofing sealant to a more visually appealing system. SleekMount as"Grounding and Bonding System" ® Insert Comp Mount flashing under upper utilizes ZepatibleTM modules with Com P •Ground Zep UL and ETL listed to UL 467 as � layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance \ S Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions ® Secure Leveling Foot to the Comp Mount using machine Screw ® Place module Components ® +� 5/16"Machine Screw Leveling Foot ® Lag Screw • Comp Mount M� I��11 Comp Mount Flashing _ � g r I �rYf 3uii�in9 Department w 2 2314 CC)POPLIANCE ��v i;wt�U 8y � � •����I GOMTAT =�1��I ,ie SolarCity, January 2013 SOW �� USTED ��� SolarCity, January 2013 e�Ed�ees,g� CUP \ -235/240/245/250/255PX N F1am _r CanadianSolar Electrical Data Black-framed gteakttita STC CS6P-235P C86P-2401` CUP-245P CS6P-2SOPX Cs6P.255Px Temperature Characteristics Nominal Maximum Power Pmax 235W 240W 245W 25OW 255W _ Optimum OperatingVoltage mp 29.8V 29.9V 30.0V 30AV 30.2V Pmex .0.43%/•C NewEdgOptimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc 1-0.34%/C Open Circuit Voltage(Voc) 36.9V 37.OV 37AV 37.2V 37AV Isc I 0.065%PC r. _ Short Circuit Current(Isc) 8.46A 8.59A 8.74A e.87A 9.00A Normal Operating Cell Temperature 4532'C ' a Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% Operating Temperature -40•C-+85•C Performance at Low Irradiance Maximum System Voltage IOOOV IEC /600V UL Industry leading performance at low irradiation Maximum series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification Class irradiance of 1000w/m'to 200w/m' Power Tolerance 0-+5W (AM 1.5,25-C) Next Generation Solar Module Under Standard Teat Condllions(STC)olirradiane.of 1000WIm',sp.ctrum AM 1.5 and all temperstursof25C NewEdge,the next generation module designed for multipleEngineering Drawings NOCT CS6P-235P CS6P-240P CSBP-246P CS6P-250PX CS6P•255PX types of mounting systems,offers customers the added Nominal Maximum Power Pmax 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless optimum o erating Voltage(Vmp) 27.2V 27,3V 27.4V 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.9V 34.0V XlV 342V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module short circuit current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zap compatible frame. under Normal operating Ceti Temperature.irradianc.of 80o W/m',.pectrum AM 1.5,ambient temperature 201C, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars 11 t 111 1 11 Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 4Omm(64.5 x 38.7 x 1,57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high weight 20.5kg(45.21bs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop ,I-sox IP65,3diodes installation costs in half Best Quality 9} Cable 4mm'(IEC)/12 4 Compab • 235 quality control points in module production G • Connectors MC4 or MComparable Aesthetic seamless appearance - low profile EL screening to eliminate product defects Standard Packaging(Modules per Pallet) 24pes with auto leveling and alignment - Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HO) • Accredited Salt mist resistant • mounted,it's roundended groundingsystem - ifit's I-V CurveS (CS6P-255PX) mounted,it's grounded Best Warranty Insurance ir E • Theft resistant hardware • 25 years worldwide coverage . I '��r-'r�TINt� • 100°k warranty term coverage section A-A Suilding Department i • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights 350 i ? and grounding system • Non-cancellable I z• _ "% 2 y 21`,1pA 9 e coverag • Industry first comprehensive warranty insurance by Immediate AM Best rated leading insurance companies in the Insured by 3 world top insurance companies o Ii world ' i" DE COMPLANCL Comprehensive Certificates ( i • Industry leading plus only power tolerance:0—+5W _ C it nom; • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, 15 � • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS ground mounting systems • IS09001:2008:Quality Management System • ISOITS16949'2009:The automotive quality 'Spedfiations included in this datasheet are subject to change without prior notice. • Backed By Our New 10/25 Linear Power Warranty management system Plus our added 25 year insurance coverage • IS014001:2004:Standards for Environmental About Canadian Solar management system Canadian Solar Inc.Is one of the world's largest solar Canadian Solar was founded In Canada in 2001 and was 1$� Added V • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In slue From Hazardous Substances Regulations manufacturer of Ingots,wafers,calls,solar modules and November 2006. Canadian Solar has module manufacturing 90% m warranty g solar systems, Canadian Solar delivers solar power capacity of 2.05GW and call manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide so% occupational health and safety customers. Canadian Solar's world class team of ox s 10 is 20 25 a REACH Compliance professionals works closely with our customers to provide them with solutions for all their solar needs. Hea. OntarioGuelph I • 10 year product warranty on materials and workmanship0 : E � � , `. •25 year linear power output warranty Fax:�1 519 837 2550 www.canadiansolar.com EN-8..10.1 r c•oyAghl 0 202 Canadian solar Inc. Additional highlights: - RS-485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and M Interruption(-A Version). i' Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US AN Mechanical 'ficati Nominal output power 3000W 360OW W00 3800W 420OW ................................................... ... ................... . ................ 3000 : 3 0 : 3300 600 40 000 i 3300 i 4200 d200' 42 4600 d600 Maximum output power wattage W W W W W W W W W W W w .......................................................................... _ Rated rid AC voila a 208V 240V 277V 208V 240V 277V 208V 24pV 277V 208V 240V 27N a Input side PQ Number of_independent MPPT channels 2 2 2 2 ....................................... .................. J" Maximum usable power for each channel 2000W 3000W 3000W..................._.....................3000W .- .................................................................... ..................... .............................. Absolute.maximum.volt.age.. m )........................................................................................................_................................._600V........................................................ - Startu volts a Start)..........._............................... 200V..(ao.:..........'......... --_ ...___........ ._ P.............g....N (ad) 120 350V)......_........................................................................................ e FuII..P..Rwer MPPT volta.9.e_�an88........................._......:..................160-530V ?.20-530V ... 140-530V.....................................140 530V................... .. .. • —-- O eratin MPPT voltage range 0.7 x Vstart580V >=90 a e Maximum cu7rent(Idcmaz)for both MPPT 16 (. �.... ... .. arallel 20A 32A 32A 32A p.................................................................................................................................................................:..........................................................:...........................................................:............................................................ Maximum usable current per channel 10A..................... 16A..................... 16A.................... 16A.......................... mu n'} t'cirouit c r nt'limt r" Maw s o u re pe 12.5A 20.OA 20. A 20.OA channel0..... i Number of wire landinq_terminals..per channel....:.............................................................................................................2..Pairs............................................_ .................................................................. Arraywirin termination Terminal block,pressure clamp,AWG10-AWG4 ou< ut aide g Grid connection type 10/ b 101 / plit- i 1 1 / s Split- ' 1 - ..............................................................................................................i...._2W.....I..0/3W.......2W.....;.....2W.......fd/3W.......2W...........2W......_0/3W........2W.....1...._21N......._rd/3W........2W....- Adjustable voltage range(Vmin-Vmax)(� ! 193- 211- i 244- 183- 211- i 244- 193- 211- 244- 183- 211- 244- 228V264V i304V 228V 264V_ 304V 228V i 264V ..304V 228V 264V 304V Gr . .... d frequency 60Hz Adjustable gr d frequency range 57-60.5Hz Maximum current(1­l 14.5 i4.5 ' i2.0 i7:2 i6.'O 16.0 18.0 ' 'f&O 19.0 20.0. 0.20. 20.0. ...................................................._................ s.........�s.........�ws.........�rws..__... us...._......ave.........Awu.........�!ws.......-�as..._ fives.._.....!?!w+s.........RnMs..._ A r lac r > "-'t Powe to 5 0.99 --a .........................................,..........,........................................................i............................................................................................................................................................................................_ ......................................... '?7 Total harmonic distortion at rated power c 2% .U r ER Y single-phase 9 high-speed Highlights: 9 type Terminal block,Pressure clamp,Awdid AWG ` 7� This family of sin le- hase strip The hi h-s eed MPPT offers real- Hi hli hts: Grid wenn termination ��N� inverters complements the typical time power tracking and improved - Single phase ands lit phase output MWR � — - Oiling De Pat@nt number of rooftop solar panels energy harvestin rid connection. Reverse polarity protection vas ......... ........................................_ p P 9Y 9 g Over-volt age..Protection.ty.P..e..........................................:..............................................................................._.......Varistor,2 for each channel................_..._.................I.................. enabling home-owners to get the most The flat efficiency curve ensures high - Wide input range for increased PV array ground fault defection Pre start-up Riso and Dynamic GFDI(requires tloating etre s] ` . ...j, �� efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Outout p"got-1 xl dlevicea 17 Anti islanding protection Meets UL 1741/IEEE1547 requirements of the property. a consistent and stable performance The high speed and precise MPPT over-voltage protection type Vanstor,2 Lzi L:QG) "r across the entire input voltage and algorithm offers real time ower 'Maximum AO OOPD Rating 20 20 9 9 P 9 A,y A,.,.' 5A,�, 25A,�, 20A,,,,[20A,,,° 20A,�° 20�°;20A,,,� 25A '2 A2 � + L f'+j�CF This inverter offers a dual input output power range. tracking and improved energy Efficiency r ` section that processes strings Th tr r n i Maximumefficien.py................................................................................_96.9%..............................................97%.................................................97%........................:_�'�.. Yr:. p o s g e ansformerless ope at o gives the harvest ng. GEG etrcienc 96% '` hT with independent Multiple Power Point highest efficiency of up to 97.0%. - Outdoor NEMA 4X rated enclosure rfo ce Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <O.sW,,° This is especially useful for rooftop the inverter suitable to low powerenvironmental conditions. Stand-by consum tlon <6w Communication installations with two different installations with reduced string size. - Integrated DC disconnect switch User-interface ..................................1.6 characters x 2lines LCD display ........... orientations from two sub arrays This rugged outdoor inverter has been in compliance with international Remote mon'itorjng(1xRS485 incl.j VSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Envtetnaf Ambient z'opereting.temperaturerange..............'..............................................................'13°F to+140°F with derating.above 122°F.(50..C)............................................................- example:East and West) unit able to withstand the harshest Ambient err storage temperature range -40'F to+176°F(-40 C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing.. .. ........................... .. ........ .. ... ......... ... ....... ... _ ............. Acoustic noise emission level c 50 db A �1 m independent MPPT enable a more ...........................................si....n..................................................................................................................................._.....................................(..)........................................................... .................._............................... Maximum o eratin agitutde wthout deretin 6560 ft 2000 m optimal energy harvesting condition. is Capability snap bled et online AC voltage and with s mcart Dc poorer available. e.................................................................................... ............................................................................................................................................................ Power and productivity for a better world' 2 ABB Solar Inverters)Product flyer for PVI-3.0/3.6/3.8/4.2-11-01JTD CUPERTINO SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 • building0kupertino.org Ave- Permit No. #0 9LD l tl Address U3 l Av # of Alarms Smoke: I Carbon Monoxide: PURPOSE This affidavit is a self - certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single - family and multi- family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and /or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel- burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access bA means of attic, basement or crawl space. Refer to CRC Section 8314 and CBC Sections 907.2.11.4 and 420.6. . n electrical permit is required for alarms which must be connected to the building wiring. 91liave r fer n ed been As owner of the above - referenced property, I hereby certify that the m(s) e e installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to comply with the terms and conditions of this statement e Signature .... .. ................ Date: ................... Smoke and CO form.doc revised 03 118114 !to