Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15030032
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 887: BETTE AVE CONTRACTOR: SOLARCITY PERMIT NO: 15030032 OWNER'S NAME: PARROTT JO A TRUSTEE 3055 CLEARVIEW WAY DATE ISSUED: 03/05/2015 OWNER'S PHONE: 4083093283 SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 LICENSED C ACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL INSTALL (25) PANEL PV SYSTEM ON SFDWL ROOFTOP 6.5 License Classel 10 uc., FF 10 -1- - _._ KW, ADD SUB PANEL O�+ Contractor Date OR/ I hereby affirmtl(a I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: ,I have and will maintain a certificate of consent to self -insure. for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation: $15000 I have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 36927052.00 Occupancy Type: Section 3700 of the Labor Code,, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN U80 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, 180 D,711,LAST CALLED INSP CTION. costs, and expenses which may accrue against said City in consequence of the Issued by: Date granting of this permit. Addition y, th plicant understands and will comply with all non -point source regula ns a Cupertino Municipal Code, Section 9.18. Signature Date—,� I -S RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: 1 hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation. will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(x) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Aft Qu Ility Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino uni al Code, Chapter 9.12 and I Sections 25505, 3, d 25534. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this the Health & Safety Code, r%S Owner or authorized agent: Date: -S permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, l become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO Address SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 E061fivid (408) 777-3228 • FAX (408) 777-3333 • building cDcupertino.org Permit No. 0� D� ���;fjt.PJ # of Alarms Smoke:.. Carbon Monoxide: • PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. r have read and anraa to romnw with the terms and conditions of this statement Owner (or Owner Agent's Nae: 1.� ,Q N Rio � Si nature....... Ir.• . . ...................................... Date: ................... Contractor Name: 46/ Signature........ - ......................................................... Lic.#...................................... Date: ................... Smoke and CO form.doc revised 03/18/14 CUPERTINO Owner Name Address WATER -CONSERVING PLUMBING FIXTURES(71 OWNER CERTIFICATE OF COMPLIANCE I COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408)) 777-3228 •FAX (408) 777-3333 • building(a.cuoertino.org Z Permit No. PERMIT CANNOT BE FINALED AND COMPLETED UNTIL THIS CERTIFICATE HAS BEEN SIGNED AND RETUNED TO THE BUILDING DIVISION Please refer to the attached California Civil Code Sections 110 1. 1 —1101.8 which are part of this Certification form. 1. Is your real property a registered historical site? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: PKI�10 Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. ❑ The licensed plumber's certification has been provided to the Building Division. Sign below and skip the rest of the form. l No Owner' Signature:Date: Go 3. yfa_�� to Question 3. Is water service permanently disconnected for your building? ❑ Yes Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: �`� Date: Go 4. No to Question 4. Is your real property built and available for use or occupancy on or before January 1, 1994? ❑ No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Sign below and skip the rest of the form. Owner' Signature: Date: Yes My real property isub ilt and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Refer to the attached. My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non-compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non-compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). ❑ Myproperty is a commercial real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. SB407 2014.doc revised 03118114 On or before January 1, 2019, all non-compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). I/We, the owner(s) of this property, certify under penalty of perjury that non-compliant plumbing fixtures have been replaced with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water -conserving plumbing fixtures comply with the requirements as indicated in the table below. Owner's (or Owner Agent's) Signature: ! & e iO iJ Date: yf,W,/l 14, — Upon completing and signing this Certificate, please return it to the Building Division in order to final your permit. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072014.doc revised 03118/14 Non -Compliant Water -Conserving Plumbing Fixture Fixture (Fixture Complying with Current Code Applicable to New Construction) —Plumbing Maximum Water Usage/Flow Rate Fixture Type Water Usage 2013 CPC Ch. 4 2013 CPC Ch. 4 2013 CPC Ch. 4 /Flow Rate 2013 CALGreen Div. 4.3 2013 CALGreen Div. 4.3 2013 CALGreen Div. 5.3 Single -Family Multi -Family Commercial Residential Residential Water Closets Exceed 1.6 Single flush toilets: 1.28 gallons/flush (Toilets) Gallons/flush Dual flush toilets: 1.28 gallons/flush effective flush volume (the composite, average flush volume of two reduced flushes and one full flush Urinals Exceed 1.0 0.5 gallons/flush Gallons/flush Showerheads Exceed 2.5 2.0 gallons per minute @ 80 psi. Also certified to the performance criteria of gallons per minute U.S. EPA WaterSense Specification for Showerheads (A hand-held shower is considered a showerhead.) For multiple showerheads serving one shower, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute @ 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. Faucets — Exceed 2.2 gallons Maximum 1.5 gallons per Within units: 0.5 gallons per minute @ 60 Lavatory per minute minute @ 60 psi; minimum Maximum 1.5 gallons psi Faucets 0.8 gallons per minute @ per minute @ 60 psi; 20 psi minimum 0.8 gallons per minute @ 20 psi In common and public use areas: 0.5 gallons per minute @ 60 psi 1.8 gallons per minute 60 psi Faucets — Exceed 2.2 gallons 1.8 gallons per minute @ 1.8 gallons per minute 1.8 gallons per minute @ 60 Kitchen per minute 60 psi @ 60 psi psi Faucets May temporarily increase May temporarily up to 2.2 gallons per increase up to 2.2 minute @ 60 psi, and must gallons per minute @ default to maximum 60 psi, and must 1.8 gallons per minute @ default to maximum 60 psi 1.8 gallons per minute Where faucets meeting @ 60 psi the above are unavailable, Where faucets meeting aerators or other means the above are may be used to achieve unavailable, aerators or reduction. other means may be used to achieve reduction. 1. If the existing plumbing fixture water usage/flow rate is equal to or lower than the figure shown, it is not required to be upgraded. SB4072014.doc revised 03118/14 CALIFORNIA CIVIL CODE SECTIONS 1101.1-1101.8 Civil Code Division 2. Property Part 4. Acquisition of Property Title 4. Transfer Chapter 2. Transfer of Real Property Article 1.4. -Installation of Water Use Efficiency Improvements ........ 1101.1 — 1101.8 1101.1. The Legislature finds and declares all of the following: (a) Adequate water supply reliability for all uses is essential to the future economic and environmental health of California. (b) Environmentally sound strategies to meet future water supply and wastewater treatment needs are key to protecting and restoring aquatic resources in California. (c) There is a pressing need to address water supply reliability issues raised by growing urban areas. (d) Economic analysis by urban water agencies has identified urban water conservation as a cost-effective approach to addressing water supply needs. (e) There are many water conservation practices that produce significant energy and other resource savings that should be encouraged as a matter of state policy. (f) Since the 1991 signing of the "Memorandum of Understanding Regarding Urban Water Conservation in California," many urban water and wastewater treatment agencies have gained valuable experience that can be applied to produce significant statewide savings of water, energy, and associated infrastructure costs. This experience indicates a need to regularly revise and update water conservation methodologies and practices. (g) To address these concerns, it is the intent of the Legislature to require that residential and commercial real property built and available for use or occupancy on or before January 1, 1994, be equipped with water -conserving plumbing fixtures. (h) It is further the intent of the Legislature that retail water suppliers are encouraged to provide incentives, financing mechanisms, and funding to assist property owners with these retrofit obligations. 1101.2. Except as provided in Section 1101.7, this article shall apply to residential and commercial real property built and available for use on or before January 1, 1994. 1101.3. For the purposes of this article: (a) "Commercial real property" means any real property that is improved with, or consisting of, a building that is intended for commercial use, including hotels and motels, that is not a single-family residential real property or a multifamily residential real property. (b) "Multifamily residential real property" means any real property that is improved with, or consisting of, a building containing more than one unit that is intended for human habitation, or any mixed residential -commercial buildings or portions thereof that are intended for human habitation. Multifamily residential real property includes residential hotels but does not include hotels and motels that are not residential hotels. (c) "Noncompliant plumbing fixture" means any of the following: (1) Any toilet manufactured to use more than 1.6 gallons of water per flush. (2) Any urinal manufactured to use more than one gallon of water per flush. (3) Any showerhead manufactured to have a flow capacity of more than 2.5 gallons of water per minute. (4) Any interior faucet that emits more than 2.2 gallons of water per minute. (d) "Single-family residential real property" means any real property that is improved with, or consisting of, a building containing not more than one unit that is intended for human habitation. (e) "Water -conserving plumbing fixture" means any fixture that is in compliance with current building standards applicable to a newly constructed real property of the same type. (f) "Sale or transfer" means the sale or transfer of an entire real property estate or the fee interest in that real property estate and does not include the sale or transfer of a partial interest, including a leasehold. 1101.4. (a) On and after January 1, 2014, for all building alterations or improvements to single-family residential real property, as a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department, the permit applicant shall replace all noncompliant plumbing fixtures with water - conserving plumbing fixtures. (b) On or before January 1, 2017, noncompliant plumbing fixtures in any single-family residential real property shall be replaced by the property owner with water -conserving plumbing fixtures. (c) On and after January 1, 2017, a seller or transferor of single-family residential real property shall disclose in writing to the prospective purchaser or transferee the requirements of subdivision (b) and whether the real property includes any noncompliant plumbing fixtures. 1101.5. (a) On or before January 1, 2019, all noncompliant plumbing fixtures in any multifamily residential real property and in any commercial real property shall be replaced with water -conserving plumbing fixtures. (b) An owner or the owner's agent may enter the owner's property for the purpose of installing, repairing, testing, and maintaining water -conserving plumbing fixtures required by this section, consistent with notice requirements of Section 1954. (c) On and after January 1, 2019, the water -conserving plumbing fixtures required by this section shall be operating at the manufacturer's rated water consumption at the time that the tenant takes possession. A tenant shall be responsible for notifying -the owner or owner's agent if the tenant becomes aware that a water -conserving plumbing fixture within his or her unit is not operating at the manufacturer's rated water consumption. The owner or owner's agent shall correct an inoperability in a water -conserving plumbing fixture upon notice by the tenant or if detected by the owner or the owner's agent. (d) (1) On and after January 1, 2014, all noncompliant plumbing fixtures in any multifamily residential real property and any commercial real property shall be replaced with water -conserving plumbing fixtures in the following circumstances: (A) For building additions in which the sum of concurrent building permits by the same permit applicant would increase the floor area of the space in a building by more than 10 percent, the building permit applicant shall replace all noncompliant plumbing fixtures in the building. (B) For building alterations or improvements in which the total construction cost estimated in the building permit is greater than one hundred fifty thousand dollars ($150,000), the building permit applicant shall replace all noncompliant plumbing fixtures that service the specific area of the improvement. (C) Notwithstanding subparagraph (A) or (B), for any alterations or improvements to a room in a building that require a building permit and that room contains any noncompliant plumbing fixtures, the building permit applicant shall replace all noncompliant plumbing fixtures in that room. (2) Replacement of all noncompliant plumbing fixtures with water -conserving plumbing fixtures, as described in paragraph (1), shall be a condition for issuance of a certificate of final completion and occupancy or final permit approval by the local building department. (e) On and after January 1, 2019, a seller or transferor of multifamily residential real property or of commercial real property shall disclose to the prospective purchaser or transferee, in writing, the requirements of subdivision (a) and whether the property includes any noncompliant plumbing fixtures. This disclosure may be included in other transactional documents. 1101.6. The duty of an owner or building permit applicant to comply with the requirements of this article shall be postponed for one year from the date of issuance of a demolition permit for the building. If the building is demolished within the one-year postponement, the requirements of this article shall not apply. If the building is not demolished after the expiration of one year, the provisions of this article shall apply, subject to appeal to the local building department, even though the demolition permit is still in effect or a new demolition permit has been issued. 1101.7. This article shall not apply to any of the following: (a) Registered historical sites. (b) Real property for which a licensed plumber certifies that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible. (c) A building for which water service is permanently disconnected. 1101.8. A city, county, or city and county, or a retail water supplier may do either of the following: (a) Enact local ordinances or establish policies that promote compliance with this article. (b) Enact local ordinances or establish policies that will result in a greater amount of water savings than those provided for in this article. CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION /,} 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 6 (408) 777-3228 • FAX (408) 777-3333 • building( cupeltino.org AE F7 K �_�7'� A Ve—. PROJECT ADDRESS (Q�J `l (0 APN# q `�Uo. !�// OWNER NAME a ' &-IVA 0 ry-ol PHONE e/q�/ ) QQ -3.22A E-MAIL STREETADDRESS tt j'L t 1LG! v� CITY, STATE, ZIPC Y 1^0 C ^ l ry C„ I! r rl FAX CONTACT NAME Marjan Javanmard PHGNE 650.477.6430 E-MAFL mj'alvanmard@solarcity.com STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 FAX 1 ❑ OWNER ❑ OWNER-BUu.DER ❑ OWNER AGENT ❑ CONTRACTOR 9 CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAMESOIarCity Corporation LICENSE NUMBER 888104 LICENSE 7EC10 BUS. LIC#28840 (�,t(�,`�-FF COMPANY NAME SoIarCity Corporation E-MAILmjavanmard@solarcity.com FAX STREET ADDRESS 391 Foster City Blvd CITY, STATE, ZIP Foster City, CA 94404 PH" 650.477.6430 ARCHITECTIENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: DESCRIPTION OF WORK Installation �5 ) rooftop flush mounted solar panel C.$) kW rn e -r y Ce-- RECEIVED BY. By my signature below, I certify to each of the following: I am the pro erty 9(yrier or authorized agent to act on the prope er s behalf. I have read this application and the information I have provided is correct. I have re fhe W6rlption of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I auth —1, 5�ese ves of Cupertino to enter the above -identified property for inspection purposes. Signature of Applicant/Agent: Date: 0 3/ n S 5 SUPPLEMENIS4L INFORMATION REQUIRED OFFICE USE ONLY m ❑ OVER-THE-COUNTER 4 F ❑ EXPRESS U U s ❑ STANDARD U ❑ LARGE a ❑ MAJOR PVApp_2011.doc revised 03/16/11 ������,, CITY OF CUPERTINO uw_9//il FF,F. ESTIMATOR - BUILDING DIVISION 19 ADDRESS: 887 bette ave DATE: 03/05/2015 REVIEWED BY: MENDEZ APN: BP#: 6c qQ 306:3,2, "VALUATION: $15,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: p 0.0 PENTAMATION SOLAR -RES PERMIT TYPE: WORK install 25 ane/ pv system on sfdwl rooftop 6.5 kw, add sub panel SCOPE F125 amps $48.00 NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, rue, sanitary SewerDistrict, Scnoot e t t These ees are based on the relimina information available and are on[ an estimate. Contact the Dept or addn7 info, is rtc , c. . FEE ITEMS (Fee Resolution 11-053 Ej/: 7i 173) FEE QTY/FEE Elec. Plan Check 0.0 hrs $0.00 Plan Check Fee: Elec. Permit Fee: IEPERMIT =# $236.00 LjOther Elea Insp. 0.0 hrs $48.00 Suppl. PC Fee: Q Reg. Q OT 0.0 hrs NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, rue, sanitary SewerDistrict, Scnoot e t t These ees are based on the relimina information available and are on[ an estimate. Contact the Dept or addn7 info, is rtc , c. . FEE ITEMS (Fee Resolution 11-053 Ej/: 7i 173) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 =# $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 F125 amps $48.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee -0 Reg. Q OT F0.01 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 ,,!N11'u( li, r IiIx Administrative Fee: (ADMIN $45.00 O E) Work Without Permit? O Yes 0 No $0.00 Advanced Planning_Fee. $0.00 Select a Non -Residential Building or Structure E) Travel Documentation Fee: ITRA VDOC $48.00 Strong. Motion Fee: IBSEISMICR $1.95 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $143.951 $284.001__TOTAL FEE: $427.95 Revised: 02/14/2015 ABBREVIATIONS I ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: * AHJ: Cupertino FLASHING WILL BE PAINTED TO MATCH EXTERIOR LOPMENT DEPA.RTMETR COWUt pIV1S10N _ CUPERTINO APPROVED ke t at the This set of pians and specifications MUST be P job site during construction. It is same, o to devito ate make any changes or alterationsoval from the Buiid`�ng Official. therefrom, without app ctrl i NOT ecifcat. Ons ��,.,�._ sM� ,ung s pl n and spi . al Of t".� `;.: a^t1 ;n perm;' UTILITY: Pacific Gas and Electric Company1 79"Wei • fj COMMENTS REV A kali, - — THE R NUMBER. J B- 9 5 0 4 4 5 5 0 0 PREMISE OWNER: PARROTT, JOANN CONTAINED SHALL NOT BECONFIDENTIAL USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 887 BETTE AVE NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES: (25) REC # REC260PEZ DESCRIPTION: RESIDENCE6.5 DESIGN: William Avery�,solarcity.PARROTT SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: (408) 309-3283 �� PERMISSION OF SOLARCITY INC. ABB# PVI-3.0—OUTD—S—US—Z—A VICINITY MAP pt_OT PLAN" CHECKED CHECKED BY DAT NINING D%1_ cUPERT' OFFICE Op ` INDEX PV1 COVER SHEET �` PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM PV6 ELECTRICAL LOAD CALCULATIONS Cutsheets Attached �i REV BY DATE COMMENTS REV A NAME DATE COMMENTS _ Wit- _, , — A— r DESCRIPTION: RESIDENCE6.5 DESIGN: William Avery�,solarcity.PARROTT KW PV ARRAY �� 3055 Cleorview Way PAGE NAME: SHEET: REV: DATE: Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 636-1029 COVER SHEET PV 1 1/29/2015 (688)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Front Of House JOB NUMBER: JB -9504455 00 MOUNTING SYSTEM: Comp Mount Tvpe C (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A PARROTT, JOANN 887 BETTE AVE CUPERTINO, CA 95014 (408) 309-3283 PARROTT RESIDENCE 6.5 KW PV ARRAY PACE NAME SITE PLAN PITCH: 11 ARRAY PITCH: 11 MP1 AZIMUTH: 110 ARRAY AZIMUTH: 110 MATERIAL: Comp Shingle STORY: 1 Si PITCH: 12 ARRAY PITCH: 12 MP2 AZIMUTH: 110 ARRAY AZIMUTH: 110 MATERIAL: Como Shingle STORY: 1 Si LEGEND (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS TOTAL ARRAY AREA (SF): 453 SITE PLAN N TOTAL ROOF AREA (SF): 2940 Scale: 3/32" = 1' 01' 10' 21' W TOTAL ARRAY AREA IS N 15.41 S PERCENT OF TOTAL ROOF AREA William Avery 6'� SHEET: REV: DATE PV 2 1/29/2015 ;SolarCit 3055 GeorAew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com DC DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS O DC JUNCTION/COMBINER BOX & LABELS 0° DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE O HEAT PRODUCING VENTS ARE RED r, Ik 11 INTERIOR EQUIPMENT IS DASHED L -=.J TOTAL ARRAY AREA (SF): 453 SITE PLAN N TOTAL ROOF AREA (SF): 2940 Scale: 3/32" = 1' 01' 10' 21' W TOTAL ARRAY AREA IS N 15.41 S PERCENT OF TOTAL ROOF AREA William Avery 6'� SHEET: REV: DATE PV 2 1/29/2015 ;SolarCit 3055 GeorAew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com (A SIDE VIEW OF MP1 NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 110 PITCH 11 STORIES: 1 ARRAY AZI 110 PITCH 11 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. S 1 STAN DOFF JOB NUMBER: JB -9504455 00 MOUNTING SYSTEM: Comp Mount Type C MODULES (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT &WASHERS. PARROTT, JOANN 887 BETTE AVE CUPERTINO, CA 95014 (408) 309-3283 SIDE VIEW OF MP2 NTS CB MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 110 PITCH 12 ARRAY AZI 110 PITCH 12 STORIES: 1 Comp Shingle PARROTT RESIDENCE 6.5 KW PV ARRAY PAGE NAME: STRUCTURAL VIEWS William Avery SHEET: REV: DATE: PV 3 1/29/2015 SolarCity 3055 Cleorview Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9504455 00 MOUNTING SYSTEM: Comp Mount Type C MODULES: (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0-0UTD—S—US—Z—A REMISE OWNER: PARROTT, JOANN 887 BETTE AVE CUPERTINO, CA 95014 (408) 309-3283 UPLIFT CALCULATIONS 01.29.2015 SolarCity PV System Structural Version #42.2 Desian Software Project Information & Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'" Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 12° Rafter S adn 24" O.C. PV System Module Orientation Landscape and Portrait PV Module Area 444 sf PV Module Width 39" PV Module Length 66" Standoff Attachment Hardware Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof RQ. 30.4-2A/B/C-5AM Mean Roof Height h 15 ft Section 26.2 Effective Wind Area 1 Module A 17.8 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kzt 1.00 Section 26.8 Wind Directionality Factor Kd 0.85 Section 26.6-1 Importance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 sf Equation 30.3-1 Ext. Pressure Coefficient (Up) GCp (Up) -0.88 Flg. 30.4-2A/B!C-5A/B Ext. Pressure Coefficient Down GCp Down 0.45 Fig. 30.4-2A/B/c-5A/B Design Wind Pressure p p = gh GC Equation 30.4-1 Wind Pressure Up p(up) -19.6 psf Wind Pressure Down down 16.0 psf Allowable Standoff Spacings X -Direction Y -Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Not -Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff Tactual -195 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 38.9% Max Allowable Standoff Spacing Portrait 48" 66" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W -PV 3 psf Net Wind Uplift at Standoff T -actual -218 lbs Uplift Capacity of Standoff T -allow 500 lbs Standoff Demand/Capacity DCR 43.6% PARROTT RESIDENCE 6.5 KW PV ARRAY PAGE NAME: UPLIFT CALCULATIONS DESIGN: William Avery SHEET: REV: DATE: PV 4 1/29/2015 SolarCit 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N 8 GEC TO N GROUND ROD �� # �� Panel Number: Inv 1: DC Ungrounded INV 1 -(l)ABB g Zi beeD3000W 24OV, Al A ## - (25) RPV Black ZEP Enabled CA # 888104 C-10 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1006676201 Inv 2: DC Ungrounded 9 I nverter' 9 M dule262260W, 234.3W PTC, MC4, 40mm, Frame, Underground Service Entrance INV 2 - (1)ABB1 PVI-3.0-OUTD-S-US-Z-A NIL: B FCI inverter, Zigbee 3000W, 24OV, 967. Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (N) 125A MAIN SERVICE PANEL ADJUST MIN. ACTIVATION VOLTAGES! N 100A/21? MAIN CIRCUIT BREAKER Inverter 1 PAR 100A 2P / 7 PVI-3.0-OUTD-S-US-Z-A ABB (E) LOADS znov SolarCity —AP• • L1 L2 F120A/2P —-- ——— N —————— —— ————— —— — — —— — EGC_I DC+ ---TN 4 1 DC+ VStdrt = 12OV A r -- — — — — — — — — — — — — — — — — — ———— — GEC DG DC- MP1: 1x10 B GND -- EGC--------------------------- — —'— — — —— —— EGC—----——————— — ----j I N ADJUST MIN. ACTIVATION VOLTAGES! - - o EGCIGEC Inverter 2 IND 6 2 � GEC —, $ qgg DC- Vstart = 120V -- —� • I PVI-3.0—OUTD—S—US—Z—A DC- MP2: 1x7 tp-ji Z 20A/2P I EGC - - - - - - - - - - - B I L2 DC+ I TO 120/240V N I I SINGLE PHASE I N EGC/ DG I pC+ 5 3 DG, VStalt = 120V --------------------------------------- UTILITY SERVICE — — _ _ _ _ _ _ _ _ _ GEC ---T N DG DC- MP2: 1x8 I —-- — — — — ——-- —— —— — — —— —— — —F----- -- —— ————— — ----j I I I —L_ (1 ) Conduit Kit; 3/4" EMT Voc* = MAX VOC AT MIN TEMP POI (1)Ground Rod; 5/8" x 8', Copper /tr A A (1)SolarCity 4 STRING JUNCTION BOX D� 2x2 STRAGS, UNFUSED, GROUNDED (1) AWG #10, THWN-2, Black (1) AWG #10, THWN-2, Red ® (1) AWG 110, THWN-2, Block Voc* = 411.68 VDC Isc —9. 01 (1) AWG 110, THWN-2, Red Vmp = 307 VDC Imp= 8.5 ADC ADC (2) AWG #10, PV WIRE, Black O T (1) AWG #10, Solid Bare Copper EGC Voc* = 411.68 VDC Isc = 9.01 ADC Vmp = 307 VDC Imp= 8.5 ADC (1) AWG #10, THWN-2, White NEUTRAL Vmp = 240 VAC Imp =14.5 AAC (1) AWG #10, THWM-2, Green EGC . _ ..- (1)Conduit Kit; 3/4" EMT ................ 70 ) AWG #8.. THWN-2,. Green, EGC/GEC ,- (1 ) Conduit. Kit;, 3/4' .EMT..... _ . (1 )AWG #10, THWN-2, Black OPF (1) AWG #10, THWN-2, Black Voc* = 329.34VDC Isc = 9.01 (1 )AWG #10, THWN-2, Red Vmp = 245.6 VDC Imp= 8.5 ADC ADC (2) AWG #10, PV WIRE, Black O (1 )AWG #10, Solid Bare Copper EGC A Voc* = 288.18 VDC Isc - 9.01 DC Vmp 214.9 VDC Imp= 8.5 ADC ®L (1) AWG #10, THWN-2, Red #10, THWN-2, Green EGC (1) AWG L L (1) AWG #10, THWN-2, White NEUTRAL Vmp = 240 VAC Imp =14.5 AAC — (1 )AWG THWN72,. Green EG /GEC (I )Conduit Kit;. 3/4" EMT ©T (1) AWG #10, THWN-2, Block Voc* = 288.18 VDC Isc = 9.01 — (1)AWG #10, THWN-2, Red Vmp 214.9 VDC Imp= 8.5 ADC ADC (2) AWG #10, PV WIRE, Black O (1 )AWG #10, Solid Bare Copper EGC Voc* = 329.34VDC Isc = 9.01 ADC Vmp = 245.6 VDC Imp= 8.5 ADC #8,. . _- (I) AWP #10, THWN-2,.Green .. EGC ................................ ................................................................ CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL BE USED FOR THE JOB NUMBER: JB -9504455 00 PREMISE OWNER: PARROTT, JOANN DESCRIPTION: PARROTT RESIDENCE DESIGN: William Avery \\ NOT BENEFIT OF ANYONE EXCEPT SOLARCITY INC., 887 BETTE AVE 6.5 KW PV ARRAY �,solarCity. MOUNTING SYSTEM:� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C CUPERTINO, CA 95014 NODDLES: (25) REC # REC260PEZ 3055 Clearview Way San Mateo, CA 94402 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE PAGE NAME SHEET: REV: DATE: SOLARCITY PEERMISSIONEOFISOLARCITY INC. THE WRITTEN INVERTER: ABB PVI -3.0 -OU TD -S -US -Z -A 408 309-3283 () THREE LINE DIAGRAM PV 5 1/29/2015 (888) (SOL>CITY ( 6582489)5 w>w.solarcci29 ity.com ELECTRICAL CALCULATIONS CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9504455 00 MOUNTING SYSTEM: Comp Mount Type C MODULES (25) REC # REC260PEZ INVERTER: ABB# PVI-3.0—OUTD—S—US—Z—A Panel Schedule Load I Breaker PARROTT, JOANN 887 BETTE AVE CUPERTINO, CA 95014 (408) 309-3283 NEC 220.83 - Residential Load Calculation Version 3.0 NEC 220.83(B) "Existing Dwelling Unit.... to determine if the existing service ... is of sufficient capacity ... The following percentages shall be used for existing loads ... First 8 kVA of load at 100%, Remainder of load at 40% NEC 220.83(B)(1) General lighting and general -use receptacles at ... 3 volt-amperes/ftp as determined by 220.12. Floor Area (3VA/sq ft) Ft VA * * NEC 220.83(B)(2) 1500 VA for each 2 -wire, 20 -ampere small -appliance branch circuit and each laundry branch circuit covered in 210.11(C)(1) and (C)(2). NEC 220.83(B)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... randl water heaters" NEC 220.83(B) Total Load PARROTT RESIDENCE 6.5 KW PV ARRAY Breakerl VA Total General Load (non -A/C load) * VA First 8 kVA of load at 100%I 8000 Remainder of load at 40% General Calculated Load (non -A/C load) * VA The larger connected load of air-conditioning or space -heating, but not both, shall be used _ _ ratl 100 Percent of Load Qty I VA Small Appliance Circuits Laundry Circuits 1 1500 Bathroom Circuits 1 1500 NEC 220.83(B)(3) All appliances ... Ranges, wall -mounted ovens, counter -mounted cooking units ... Clothes dryers that are not connected to the laundry branch circuit ... randl water heaters" NEC 220.83(B) Total Load PARROTT RESIDENCE 6.5 KW PV ARRAY Breakerl VA Total General Load (non -A/C load) * VA First 8 kVA of load at 100%I 8000 Remainder of load at 40% General Calculated Load (non -A/C load) * VA The larger connected load of air-conditioning or space -heating, but not both, shall be used _ _ ratl 100 Percent of Load Max Heating and Air -Conditioning load * VA Sum of General Calculated Load * VA & Heating and A/C Load * A PAGE NAME ELECTRICAL LOAD CALCULATIONS William Avery SHEET: REV: DATE:- PV ATEPV 6 1/29/2015 solarCity. 3055 Cleorview Way San Mateo, CA 94402 T:(65O) 638-1028 F:(65O) 638-1029 (888)—SOL—CITY (765-2489) www.solorcity.com Breakerl VA Sum of A/C Equipment Sum of Electric Furnaces Max Heating and Air -Conditioning load * VA Sum of General Calculated Load * VA & Heating and A/C Load * A PAGE NAME ELECTRICAL LOAD CALCULATIONS William Avery SHEET: REV: DATE:- PV ATEPV 6 1/29/2015 solarCity. 3055 Cleorview Way San Mateo, CA 94402 T:(65O) 638-1028 F:(65O) 638-1029 (888)—SOL—CITY (765-2489) www.solorcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: Label Location: CAUTION (D) (POI) (AC) (POI) PHOTOVIC SYSTEM Per Code: Per Code:CIRCUIT � � D CEC 690.64.B.4 CEC 690.14.C.2 Wlilk MR, • CAUTION ' • •h I V - • • • - DUAL POWER SOURCE ' " • • " SECOND SOURCE IS PHOTOVOLTAIC SYSTEM Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �� �� �/ 3 n M teo, Cw Way �- San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set j ���� 7:(650) 638-1028 89) ww 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ��Solaitit 888) -SOL -CITY (765-2489)wwwsolarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ° ",,',SolarCity ZepSolar Zep System for composition shingle roofs Q��MP4Tyd �F h �p�OMPPt�O zepsolar.com Next -Level PV Mounting Technology ground kP Interlock Key sd_ sr:avr Leveling Foot / Zep Co Pp Uble PV Module �f Zep Gi —1 i Roof Attachment Army SWrt i Description • PV mounting solution for composition shingle roofs • Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules • Auto bonding UL -listed hardware creates structual and electrical bond Specifications • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Attachment method UL listed to UL 2582 for Wind Driven Rain This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 1 of 2 ;�,SolarCity ZepSolar Components Next -Level PV Mounting Technology Comp Mount Part No. 850-1345 Listed to UL 2582, Mounting Block to UL 2703 Interlock Part No. 850-1388 Listed to UL 2703 Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's ads warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 22 14 ZS for Comp Shingle Cutsheet Rev 02.pdf Page: 2 of 2 This family of single-phase string The high-speed MPPT offers real - inverters complements the typical time power tracking and improved number of rooftop solar panels energy harvesting. enabling home -owners to get the most The flat efficiency curve ensures high efficient energy harvesting for the size efficiency at all output levels allowing of the property. a consistent and stable performance ........... ..............._.................. .... across the entire input voltage and This inverter offers a dual input output power range. section that processes two strings The transformerless operation gives the with independent Multiple Power Point highest efficiency of up to 97.0%. Tracking (MPPT). The wide input voltage range makes This is especially useful for rooftop the inverter suitable to low power installations with two different installations with reduced string size. orientations from two sub -arrays This rugged outdoor inverter has been oriented in different directions. (For designed to be a completely sealed example: East and West) unit able to withstand the harshest The dual input sections with environmental conditions. independent MPPT enable a more 3000W optimal energy harvesting condition. ........2...0... Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). t' Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanical specifications Adjustable voltage range (Vmin-Vmax) M 183 211 - 228V 264V Nominal output power 3000w 360OW 3W0 380OW 420OW ........... ..............._.................. .... 3000 :` 3300' :3300' 3600 4000' 4000' 3300 4200' 4200' 4200: 4600' :4600' Maximum output power wattage W W W W W W W W W W W W Rated grid AC voltage 208V 240` :: 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input side (DC) Maximum current (h�,m.) ... ._........... ..................... ............ ....' `aMe..: ....'.S�Ma ...2.....s Number of independent MPPT channels ......... 2 2 22 Power factor Maximum usable power for each channel 000W ...................... ......... ..__. 3000W 3000W .... .................. 3000W ....._................................................... Absolute maximum voltage (Vmax) ........2...0... 60ov Start-up voltage (Vstart)200V Grid wiring termon inatitype (adl 120 350V) Terminal block, Pressure clamp, AWG10-AWG4 Full power MPPT voltage range, 160-530V 120 530V 140 530V ........ .....-. ........ . 140-530V Operating MPPT voltage range ......... ......0.7 x Vstart..:_580V (>= ........... Reverse polarity protection Maximum current (ldcmax) for both MIyP7 in 20A 32A 32A 32A parallel..... _._. _.................................. .. .................. Maximum usable current per channel 10A 16A 16A ..................._ . .. 16A Maximum sholl circuit current limit per I12.5A _ 20.OA 20.OA 20.OA channel Anti -islanding protection Number of wire landing terminals per channel 2 pairs _ Over -voltage protection type Arrav wiring termination Varistor, 2 (L, - L2 / L, - G) Terminal block, pressure clamp, AWG10-AWG4 algorithm offers real time power W Grid connection type IUB spur 2W 0/3W IUB 110/ opnr twi IUB opur IYJ/ 2W 2W 0/3W 2W 2W 0/3W 2W IIO/ aPI«- I,cn 2W 0/3W 2W Adjustable voltage range (Vmin-Vmax) M 183 211 - 228V 264V 244- 183- 211- - 244- 183 211 244--- 304V 228V 264V 304V 228V 264V 304V,. 183 211 244- 228V ..264V 304V Grid frequency 60Hz ..................... Adjustable grid frequency range 57 60.5Hz 114.5 114.5 12.0 17.2 16.0 1 16.0 16.0 16.0 16.0 210.0 20.0 210:0 Maximum current (h�,m.) ... ._........... ..................... ............ ....' `aMe..: ....'.S�Ma ...2.....s .d.....!�aMs... . p'w.�b ... ...:�Ma..._....Awas...._.. !?wns. .. ?nws... 'Rna..._...!.a - ..'Y�Ma..... Power factor > 0.995 Total harmonic distortion at ratedpower <2% Highlights: Grid wiring termon inatitype Terminal block, Pressure clamp, AWG10-AWG4 — Single phase and split phase output Input protection devices Reverse polarity protection Yes grid Connection. Over -voltage protection type Varistor, 2 for each channel — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI (requires floating arrays) stringing flexibility. Output protection devices Anti -islanding protection Meets UL 1741/IEEE1547 requirements — The high speed and precise MPPT 9 P p _ Over -voltage protection type Varistor, 2 (L, - L2 / L, - G) algorithm offers real time power Maximum AC OCPD Rating 20Ag„ i 20A_ 15Ap„, 25Ap„. 20A,„,, : 20A,,,,, 20A_ i 20Ap„, l 20Ag„, 25A_ 2m i 2M_ tracking and improved energy Efficiency Maximum efficiency 96.9% 97% 97% 97% harvesting. g CEC efficiency._ _ 96% — Outdoor NEMA 4X rated enclosure Operating performance for unrestricted use under any Night time consumption < 0.6w Stand-by consumption <8W,_ environmental conditions. e Communication — Integrated DC disconnect switch User -Interface 16 characters x 2 lines LCD display _ in compliance with international Remote monitoring (lxRS485 incl.) VSN706 Data Logger (opt.) Standards (S Version). Environmental Ambient air operating temperature range -13°F to +140°F with clerating above 122°F 50°C Ambient air storage temperature range 40°F to +176°F (-40 to +80°C) Cdensing Relative humidity 0 100% RH con Acoustic noise emission level < 50 db A ®1 m i) _ Maximum operating altitutde without derating ... .............. 6560 ft (2000 m) Power and productivity 1. Capability enabled at noewnal AC voAage and with sufficient DC power available. for a better worldTM 2 ABB Solar Inverters (Product flyer for PVI -3.0/3.6/3.8/4.2 -TL -01,1713 W HIGH PERFORMANCE SOLAR PANELS REC PEAK ENERGY REC Peak Energy Z -Link Series solar panels are the perfect choice for building solar systems that combine long lasting product quality with reliable power output. REC combines high quality design and manufacturing standards to produce high- performance solar panels with uncompromising quality. REC PEAK ENERGY Z -LINK SERIES 65.55 ±0.1 1.38 39.02 - £;i £ EFFICIENCY Nomina I Operating Cell Temperature (NOCT) YEAR PRODUCT WARRANTY Temperature Coefficient of P_ YEAR LINEAR POWER Temperature Coefficient of V. OUTPUT WARRANTY �VrV.FR 0.024%/°C 3 strings of 20 cells with bypass diodes US IMPORT DUTY FREE FF Glass: 0.125 in solar glass with anti -reflection Nomina I Operating Cell Temperature (NOCT) 4S.7°C(t2°C) Temperature Coefficient of P_ -0.40%/°C Temperature Coefficient of V. -0.27%/°C Temperature Coefficient offIsc 0.024%/°C All measurements In Inches ELECTRICAL DATA@ STC REC260PEZ Nominal Power -P,P(Wp) 260 GENERALDATA Cell Type: 60 REC PEmulti-crystalline Watt Class Sorting-(Wp) -/-5 3 strings of 20 cells with bypass diodes NominalPowerVoltage-V,(V) 30.7 Glass: 0.125 in solar glass with anti -reflection surface treatment Nominal Power Current -1,,P,(A) 8.50 BackSheet: Double layer highly resistant polyester Open Circuit Voltage-Voc(V) 37.8 Frame: Anodized aluminum (black) Short Circuit Current- Isc (A) 9.01 Zep Groove compatible Panel Efficiency(%) 15.8 Junction Box: IP67rated 0.156 in (12 AWG) solar cable, 2 x4724 in The electrical characteristics arewithin/-10% ofthe indicated values of l5�,V, and PM„ at standard Test conditions Values at standard test conditions STC (airmass AM 1.5, irradiance 1000 W/m2, cell temperature 77'F (25°C)). (STC). m P Connectors: H4Ahenol At low irradiance of 200 W/m2 (AM 1.5 & cell temperature 77'F (25"C)) at least 97% of the STC panel efficiency will be achieved. Origin: Made in Singapore Nominal Power-P,e(Wp) ,•MAXIMUM 197 RATINGS Operational Temperature: -40...+185°F(-40...+85°C) Nominal PowerVoltage-V. (V) 29.0 Maximum System Voltage: 1000VUL Nominal Power Current -I,,p(A) 6.81 Design Load: 501bs/ft2(2400Pa) longside Open Circuit Voltage -Voc (V) 35.7 301bs/ft2 (1436 Pa) short side Short Circuit Current -Isc(A) 7.24 Max Series Fuse Rating: 15A Nominal operatingcell temperature NOCT(800 W/m2,AM1.5, windspeedI m/s, ambient temperature 68"F(20"C). Max Reverse Current: 15A MECHANICAL DATA 10 year product warranty. Dimensions: 65.5 5 x 39.02 x 1. 57 in (1665 x 9 91 x 40 mm) a C @us 25 year linear power output wa rranty Area: 1775 ft2 (1.65 m2) LOTED (max. degression in performance of 0.7%p.a.). UL 1703, Fire rating: Type 1, Class C Weight: 431b5(19.5 kg) o Note! All given specifications are subject to change without notice at any time. REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better R EC meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker..RECSOL).Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com N