Loading...
B-2017-1556 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO::B-2017-1556 21451 MILFORD DR CUPERTINO,CA 95014-1329(326 41 108) BAY AREA SOLAR SOLUTIONS INC PLEASANTON,CA 94588 OWNER'S NAME: RAMA ARUN AND BHUVANA DATE ISSUED:09/12/2017 OWNER'S PHONE:408-800-9623 1 PHONE NO:(925)380-9500 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class CC=10 Lic.#928652 Contractor BAY AREA SOLAR SOLUTIONS INC Date 02/28/2019 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N)8-PANEL ROOF MOUNTED PV SYSTEM(2.56 KW) I hereby affirm under penalty of perjury one of the following two declarations: i. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the 400 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$6000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information,is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 326 41 108 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. , s, o3tratjreJ ft' _ALT Date 9/12/2017 Issued by:Abby Ayende . Date:09/12/2017 OWNER-BUILDER DECLARATION 1 hereby affirm'that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is 1. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for • compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:9/12/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. Twill permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. , ner or authorized agent: APPLICANT CERTIFICATION Date:9/12/2017 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Signature Date 9/12/2017 Licensed Professional 13-?ot - I // ALTERNATIVE ENERGY PERMIT APPLICATION QP' AE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION �5,•,,,s 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERT- (408)777-3228•FAX(408)777-3333•building o,cupertino.orci PROJECT ADDRESS AVE# 326-411708 21451 MILFORD DRIVE OWNER NAMEARUN RAMA PHONE 408-800-9623 E-MAIL bhuvanaram@yahoo.com . STREETADDREss 21451 MILFORD DRIVE .CITY,STATE'Zr! CUPERTINO,CA 95014 FAX - • CONTACT NAME PHONE E-MAIL John Woolway 9253809500 John.Woolway@yourenergysolutions.com STREET ADDRESS 6700 Santa Rita Rd CITY,STATE,ZIP FAX ��--,.// Pleasanton,CA,94588 Elga OWNER 0 OWNER-BURDER 0 OWNER AGENT ❑CONTRACTOR CONIRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0'DEVELOPER 0 TENANT CONTRACTOR.NAME LOU Zughbaba LICENSE NUMBER 928652 LICENSE. TYPE CIO BUS.LIC# COMPANY NAME E-MAIL FAX Your Energy Solutions STREET ADDRESS 6700 Santa Rita Rd CITY,STATE,ZIP PHONE Pleasanton,CA,94588 9253809500 ARCHITECT/ENGINEER.NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF M'SFD or Duplex CI Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: CI Commercial URBAN INTERFACE AREA ❑.Yes lgr No FLOOD ZONE 0 Yes NJ/No VSOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER - FOR SOLAR PANELS: NUMBER OFPANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: $6.000 DESCRIPTION OF WORK Installation of 8 Panels with a system size of 2.560 TIECEIVEDBY k?' A ., a 3.; ` By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws rela' building c�on�sllycton. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: /G� U/ Date: 9/12/17 u IBLTPPLEMENTAL INFO REQUIRED :a a . . .Q „rt�a�.OFPICE^USE�ONTsYa� :��� 1:3',71A ❑ OVER TlL COUF BR 4 1``. ' `s ❑ EXRS4 4 * �tl \ ',N n7 e ❑,.STAAu e s�, xnI„r U st i ' Zs t ,,s3'4 ❑ LARGE i n ' - - - - - ,:,71,4 t®„MA Oit2> s4'.'N si':c, i . PVApp_2011.doc revised 03/16/11 F. rnm SMOKE / CARBON MONOXIDE ALARMS 0 TOO 10F 1 • OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333 •buildinq(a cupertino.orq PERMIT CANNOT BE FINALED UNTIL THIS CERTIFICATE HAS BEEN COMPLETED,SIGNED;AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314, R315,2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds' $1000.00, CRC Section R314,R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedrooms)-(Smoke alarms shall not be located within 3 feet of bathroom door) On every level of a dwelling unit including basements and habitable attics X X Within each sleeping room X 1 t Carbon Monoxide'alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s)may be solely battery;operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space. Refer'to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational,;as of the date signed below. / Address: 2. / its / f LF�.1O , . Permit No. 13-20/7-/.S-S6 ' I - ' Specify Number of Alarms: #Smoke Alarms: le #Carbon Monoxide Detectors: I I I I have read and agree to comply with the terms an c nditions of this statement Owner(or Owner Agent's)Name: Signature ... ... .. Date: ' Contractor Name: Signature Lic.# Date: Smoke and CO form.doc revised 01/10/2017 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS6700 Santa Rita Road #E, Pleasanton, CA 94588Phone: (888) 888-0711CSLB #928652 (B, C-10) EXP. 02/28/2019X____________ ______________ISSUED FOR: PERMIT DATE: Solar Photovoltaic System9/7/2017 ARUN RAMA21451 MILFORD DRIVECUPERTINO, CA, 95014 PV-1 PROJECT INFORMATION VICINITY MAP SHEET INDEX APPLICABLE CODES PLAN SET LEGEND SUB SERVICE PANEL AC DISCONNECT DC DISCONNECT SOLAR LOAD CENTER INVERTER SUB AC DC SLC INV JUNCTION BOXJB COMBINER BOXCB ABBREVIATIONS EXTERIOR INTERIOR EXT INT NEW(N) EXISTING(E) ELECTRICAL METALLIC TUBINGEMT RIGID METALLIC TUBINGRMT VOLTAGE OPEN CIRCUITVOC VOLTAGE AT MAX. POWERVMP SHORT CIRCUIT CURRENTISC CURRENT AT MAX. POWERIMP AHJ NOTES PV MONITORING METERM NOT TO SCALENTS OCCUPANCY: R-3 CONSTRUCTION TYPE: VB UNSPRINKLERED MAIN SERVICE PANELMSP PROJECT INFORMATION ALL WORK TO COMPLY WITH THE FOLLOWING CODES: 2016 CA BUILDING CODE 2016 CA RESIDENTIAL CODE 2016 CA MECHANICAL CODE 2016 CA ELECTRICAL CODE 2016 CA GREEN CODE 2016 CA PLUMBING CODE 2016 CA ENERGY CODE 2016 CA FIRE CODE PV-1 PROJECT INFORMATION PV-1A SITE PLAN, HOUSE PHOTO PV-2 ROOF PLAN PV-2A ATTACHMENT DETAILS PV-3 ELECTRICAL LINE DIAGRAM & ELECTRICAL CALCULATIONS PV-3A ELECTRICAL NOTES PV-4 & 4A REQUIRED SIGNAGE ENPHASE AC SOLAR PVENCOMBINER BOX CITY PERFORMANCEPM MAIN BREAKER ONLYUM/MB UTILITY METER & METER RAPID SHUTDOWN BOXRS 8 X 320 W LG Electronics LG320N1K-A5 (E) 16 X 265 W Mitsubishi Electric PV-MLE265HD ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES 8 X 250 W Enphase Energy M250-60-2LL-S2X (E) 16 X 250 W Enphase Energy M250-60-2LL-S2X SYSTEM SIZE: 2.560 kW DC STC, 6.031 kW AC ARRAY AREA: 147 SF AHJ: CITY OF CUPERTINO APN: 326-411-08 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA 95014 ELECTRIC VEHICLEEVCHARGER PROJECT SITE SEAN HATCH 09/12/17 09/12/17 B-2017-1556 Abby Ayende B1 B1 B1 B1 B1 B1 B1 B1 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 SCALE: 1":15'-0" N SCALE: N.T.S. HOUSE PHOTO SITE PLAN PV-1A SITE PLAN, HOUSE PHOTO ARRAY LOCATION MICROINVERTER WITH BUILT IN RAPID SHUTDOWN LOCATED AT EACH PANEL BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 1 8 16°, 100° TOTAL # OF PANELS 8 (E) ONE-STORY HOUSE (E) DRIVEWAY (N) SOLAR PV ARRAY PER TABLE BELOW SEE PV-2 FOR ROOFTOP EQUIPMENT CALLOUTS AND ROOF AND ARRAY DIMENSIONS. FIRE ACCESS POINT 1 2 3 4 SITE PLAN LEGEND 1 2 3 4 PL PL PL PL PL (E) SOLAR PV ARRAY 5 5 82'-7" 96'-0" 97'-3" 32'-5" 24'-4" 6'-1"15'-9" 7'-3" 22'-5" 5'-0" MSP SEAN HATCH 09/12/17 B1 B1 B1 B1 B1 B1 B1 B1 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 SCALE: 1":10'-0" ROOF PLAN N ARRAY & ROOF INFO MODULE TYPE, DIMENSIONS & WEIGHT PV-2 ROOF PLAN MICROINVERTER WITH BUILT IN RAPID SHUTDOWN LOCATED AT EACH PANEL 1 METAL DECRA TILE 2x6 RAFTERS @ 24" o.c 100 16 449 100 16 147.2 32.8% 8 72 Roof Plane Roof Type: Roof Framing: Roof Azimuth (deg): Roof Slope (deg): Roof Area (sf): Array Azimuth (deg): Array Tilt (deg): Array Area (sf): % Coverage of Roof # of Panels Attachment spacing (in): PANEL TYPE: LG320N1K-A5 PANEL WEIGHT: 39.68 LB PANEL DIMENSIONS: 66.38 IN. X 40 IN. PANEL AREA: 18.40 SF UNIT WEIGHT OF PANELS: 39.68LB/18.4SF = 2.16 PSF RACKING 0.22 PSF AREA PER ATTACHMENT: 6'X2.77' = 16.6 SF WEIGHT PER ATTACHMENT: 16.6SFX2.38PSF = 44.8 LB ALL ARRAY AND ROOF INFORMATION IS SHOWN TO THE RIGHT INCLUDING FRAMING AND ATTACHMENT SPACING. SLOPE CONDUIT SHALL BE EMT CONDUIT (EXTERIOR) OR EMT OR FMC AS AHJ ALLOWS (INTERIOR), CONTRACTOR TO RUN CONDUIT ON ROOF AND UNDER EAVES OR WITHIN ATTIC. CONDUIT RUN TO BE DETERMINED AT THE TIME OF INSTALL. ANY EXPOSED CONDUIT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACE. FIRE ACCESS POINT 1 2 3 ROOF PLAN LEGEND (E) INTERIOR RAFTER SUPPORT (E) EXTERIOR WALL 1 2 3 4 4 (N) CONDUIT ROUTE MSP 6'-6" 3'-0" 780'-0" 3'-0" 4'-2" JB (E) PLUMBING VENT (E) ROOF VENT (E) SKYLIGHT 5 6 7 5 6 7 SEAN HATCH 09/12/17 5 16"Øx3"" S.S. LAG SCREW (2x) W/ 3" MIN. PENETRATION (E) RAFTER. SEE ROOF INFO AUSSIE HOOK 3" 5 2/3" SOLAR MODULE TOP DOWN MID CLAMP 1 4 "-20 FLANGE NUT (TYP.) 1 4 "-20 T-BOLT (TYP.) 3 8 "x1 1 4" S.S. HEX HEAD BOLT W/ 3 8" FLANGE NUT UNIRAC RAIL 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 PV-2A ATTACHMENT DETAILS SCALE: 1/2" = 1'-0" ATTACHMENT DETAIL SEAN HATCH 09/12/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 SINGLE LINE DIAGRAM SCALE: N.T.S. ELECTRICAL SINGLE LINE DIAGRAM 600 V, NEMA 3R W/ EUROSTRIP OR POLARIS IT CONNECTORS JUNCTION BOX A ELECTRICAL EQUIPMENT CALLOUTS MICRO INVERTER AT EACH MODULE SEE PV-3A FOR ELECTRICAL NOTES PV BREAKER IS TO BE LOCATED AT THE OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. MODULES ARE CONNECTED IN PARALLEL, NOT IN SERIES. EACH MICROINVERTER IS EQUIPPED WITH RAPID SHUTDOWN CAPABILITIES. PV-3 TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1PH, 120/240V, 3W IRREVERSIBLE GROUNDING CONNECTION BOND TO EXISTING UFER (3) #12 THWN-2 B LOW MEAN TEMP PER ASHRAE HANDBOOK MFR VOLTAGE TEMP COEFFICIENT (oC) VOLTAGE LOW TEMP. CORR. (oC) HIGH AMBIENT TEMP (oC) CONDUIT HEIGHT (in) ROOF TOP ADDED TEMP PER Table 310.15(B)(3)© (oC) ADJUSTED TEMP TEMP CORRECTION ROOF 0 -0.27 1.07 32 0.5-3.5 22 54 .76 WALL 0 32 N/A 0 32 .96 2.560kW DC STC, 1.93 kW AC SOLAR ARRAY 8 LG Electronics 320W MODULES TOTAL PANEL DECAL LG Electronics LG320N1K-A5 320W Vmp= 33.3V Voc= 40.8V Isc= 10.19A Imp= 9.62A CEC PTC POWER=294.7W Enphase Energy M250-60-2LL-S2X INVERTER MAX DC VOLTAGE: 48V DC VOLTAGE INPUT RANGE: 16-48V @240V PEAK POWER TRACKING VOLTAGE: 27-39V @240V AC NOMINAL VOLTAGE/RANGE: 211-264V @240V MAX AC OUTPUT CURRENT: 1A CEC WEIGHTED EFFICIENCY: 96.5% @240V 0.25kW INVERTER UNGROUNDED ENPHASE ENERGY M250-60-2LL-S2X (240V) INVERTER 240 VAC, 1 A NEMA 3R, UL LISTED, (WITH INTEGRATED DC DISCONNECT) (E) 125A MAIN SERVICE PANEL (E) MAIN SERVICE DISCONNECT 240V, 100A CENTER FED 2-POLE 15A PV BREAKER, BACKFED MAX PV VOLTAGE & CURRENT CALCS: RECORD LOW TEMP (˚C): (PER ASHRAE HANDBOOK) TEMP COEFFICIENT (Voc) PER MANUFACTURER: -0.27%/C VOLTAGE CORRECTION: 1.07 MAX PV SYSTEM VOLTAGE (PER CEC 2016 690.7): (Vcorrection * Voc) (1.07*40.8) = 43.7V MAX PV CONTINUOUS CURRENT PER CEC 2016 690.8(A)(1): 1.25 X Isc X # STRINGS 1.25*10.19 = 12.74A 120% RULE - CENTERFED BUS BAR MAIN BREAKER ALLOWED MAX PV OCPD 125 100 50 WIRE TAG # CONDUIT WIRE QTY (CARRY CURRENT) WIRE GAUGE (AWG) WIRE TYPE WIRE LENGTH (FEET) TEMP RATING: WIRE LOCATION ADJUSTED WIRE TEMP WIRE AMP TEMP CORRECTION PER TABLE 310.15(B)(2)(a): CONDUIT FILL PER Table 310.15(B)(3)(a): WIRE OCP: TERMINAL 75oC RATING INVERTER QTY: AC OUTPUT CURRENT CEC 690.8(A) STRING AMPS GROUND SIZE GROUND TYPE OCPD CHECK 1 NONE 3 12 TRUNK CABLE 15 90°C ROOF 54 30 X 0.76 X 1 = 22.8 25 1 X 1 X 1.25 = 1.25 #6 SBC NONE 2 3/4" EMT 3 10 THWN-2 60 90°C ROOF 54 40 X 0.76 X 1 = 30.4 35 8 X 1 X 1.25 = 10 #8 THWN-2 15A 2P BRANCH CIRCUIT # OF PANELS TILT, AZIMUTH 1 8 16°, 100° TOTAL # OF PANELS 8 (E)2-POLE 20A PV BREAKER BRANCH CIRCUIT B B JB A 1 MICROINVERTER PER PANEL EXISTING PV SYSTEM (E)1-POLE 15A PV BREAKER EXISTING PANEL DECAL Mitsubishi Electric PV-MLE265HD 265W Vmp= 31.7V Voc= 38.2V Isc= 9.08A Imp= 8.38A CEC PTC POWER=239.3W (16) PV-MLE265HD PV MODULES EACH MODULE HAS OWN ENPHASE M250-60-2LL-S2X SEAN HATCH 09/12/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 PV-3A ELECTRICAL NOTES ELECTRICAL NOTES ADDITIONAL AHJ REQUIRED ELECTRICAL NOTES 1. PV ARRAYS ARE PER SINGLE LINE.. 2. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. 3. USE UFER GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND ELECTRODE PER CEC 250.58. 4. ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. 5. CONNECTORS SHALL BE POLARIS OR EUROSTRIP IT CONNECTORS. 6. INVERTER SHALL BE PER SINGLE LINE, SEE ATTACHED CUT SHEET. 7. AC DISCONNECT SHALL BE PER SINGLE LINE. 8. EQUIPMENT GROUNDING CONDUCTORS ON AC AND DC SIDE SIZED ACCORDING TO CEC 690. 9. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. 10. MAXIMUM DC VOLTAGE DROP SHALL BE 1.5% 11. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 12. ALL WORK TO COMPLY WITH 2016 CALIFORNIA ELECTRIC CODE, 2016 CALIFORNIA BUILDING CODE 13. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. 14. 3.0 PSF MAX (.5 PSF FROM RACKING, 2.5 PSF FROM MODULES) DEAD LOAD CONTRIBUTED FROM SOLAR ARRAY. 15. CONDUCTORS ON ROOF ARE TO BE 1/2" TO 3" OFF OF THE ROOF SURFACE. 16.GEC TO BE CONNECTED TO EXISTING UFER. IF UFER IS NOT PRESENT THEN A NEW GROUND ROD WILL BE ADDED FOR GROUNDNG PURPOSES. 17. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS WHITE. 18. AN EQUIPMENT GROUNDING CONDUCTOR SHALL NOT BE SMALLER THAN 14 AWG. 19. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. RACKING & MODULES ARE GROUNDED VIA A CONTINUOUS #6AWG COPPER CONDUCTOR CONNECTED W/ UNIRAC INTEGRATED GROUND. MODULES ARE FACTORY PROVIDED W/ 2 THREADED HOLES TO FACILITATE LANDING OF THE LUGS DC SIDE OF ARRAY IS UNGROUNDED AND THEREFORE GEC IS NOT REQUIRED. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH ARTICLE 250. ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES PER CEC 690.9 (A) GROUNDING: UNIRAC INTEGRATED CLAMP MODEL # 30-20-27-C UL LISTED #2703 SEAN HATCH 09/12/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 PV-4 REQUIRED SIGNAGE ON THE FACE OF THE MAIN SERVICE DISCONNECT PER NEC 690.15 & NEC 690.13(B): CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED ON ALL INTERIOR AND EXTERIOR PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND JUNCTION BOXES CRC R331.2 & CFC 605.11.1: WARNING: PHOTOVOLTAIC POWER SOURCE MARKING SHALL BE REFLECTIVE AND PLACED EVERY 10 FEET AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND AT ALL PV COMBINER AND JUNCTION BOXES. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 3/8" HIGH LETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. PLAQUES SHALL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO PLATING, IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH APPROVED ADHESIVE. MINIMUM OF 3/8" HIGH WHITE LETTERING ON RED BACKGROUND. LOCATED AT BACKFED BREAKER. CEC 690.64 AND 705.12(D)(3)(4)(b) PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE PER CEC 690.35(F). WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ANY PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL ALSO HAVE LABEL IDENTIFIED EVERY 10 FEET - AND WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS. WARNING INVERTER CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. ON FACE OF THE SERVICE METER PANEL PER CEC 690.54 & CEC 705.12(D)(4): WARNING DUAL POWER SOURCE. SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM ON FACE OF THE SERVICE METER PANEL PER CEC 690.56 (C): PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN ADJACENT TO THE MAIN SERVICE DISCONNECT PER NEC 690.15 & NEC 690.13(B): MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING AC MICRO INVERTERS LOCATED ON ROOFTOP ARRAYS. PLAQUE TO BE INSTALLED AT ELECTRIC SERVICE: SIGNAGE AT CONDUIT & BOXES: SIGNAGE AT MAIN SERVICE PANEL: 1 MSP1 FRONT OF HOME CAUTION SERVICE POINT & UTILITY METERING (N) SOLAR ARRAY YOU ARE HERE 21451 MILFORD DRIVE, CUPERTINO, CA 95014 MAP PLACARD ON FACE OF THE MAIN SERVICE PANEL: MSP2 MSP3 MSP4 MSP5 MSP6 2 MSP7 RATED AC OUTPUT CURRENT = 8A AC NORMAL OPERATING VOLTAGE = 240V SEAN HATCH 09/12/17 1 2 - - BAY AREA SOLAR SOLUTIONS dba YOUR ENERGY SOLUTIONS 6700 Santa Rita Road #E, Pleasanton, CA 94588 Phone: (888) 888-0711 CSLB #928652 (B, C-10) EXP. 02/28/2019 X____________ ______________ ISSUED FOR: PERMIT DATE: Solar Photovoltaic System 9/7/2017 ARUN RAMA 21451 MILFORD DRIVE CUPERTINO, CA, 95014 PV-4A REQUIRED SIGNAGE ON DISCONNECTING MEANS IN 1 4" HIGH LETTERING PER CEC 690.17 (E). WARNING ELECTRICAL SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. LABEL FOR SOLAR AC DISCONNECT PER NEC 690.15 & NEC 690.13(B): PHOTOVOLTAIC AC DISCONNECT ON FACE OF THE UTILITY AC DISCONNECT: PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION ON FACE OF THE UTILITY AC DISCONNECT PER NEC 110.27(C): WARNING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL. ON FACE OF THE AC DISCONNECT PER CEC 690.54: SIGNAGE AT AC DISCONNECT: C1 AT THE UTILITY INTERACTIVE INVERTER OR GROUND FAULT INDICATOR STATING PER CEC 690.5(C): WARNING ELECTRICAL SHOCK HAZARD. IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNDERGROUNDED AND ENERGIZED. SIGNAGE AT GROUND FAULT INDICATOR: C2 C3 C4 C5 B1 RATED AC OUTPUT CURRENT = 8A AC NORMAL OPERATING VOLTAGE = 240V PV SYSTEM AC DISCONNECT SEAN HATCH 09/12/17 LG’s new module, LG NeON® 2, ado pts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. LG NeON® 2 demonstrates LG’s efforts to increase customer’s values performance under real environment, and aesthetic design suitable for roofs. Enhanced Performance Warranty High Power Output Aesthetic Roof Double-Sided Cell Structure Better Performance on a Sunny Day Outstanding Durability LG320N1K-A5 LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in countries in the following 2 years, thereafter. In 2013, LG NeON® (previously known as Mono X® NeON) won “Intersolar Award”, which proved LG is the leader of innovation in the industry. About LG Electronics 60 cell L LG NeON® 2 Black has an enhanced performance warranty. The annual degradation has fallen from -0.6%/yr to -0.55%/yr. Even after 25 years, the cell guarantees 1.2%p more output than the previous LG NeON® 2 Black modules. LG NeON® 2 Black has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may help increase the value of a property with its modern design. LG NeON® 2 Black now performs better on sunny days thanks to its improved temperature coefŅciency. Compared with previous models, the LG NeON® 2 Black has been designed to signiŅcantly enhance its output efŅciency, thereby making it efŅcient even in limited space. With its newly reinforced frame design, LG has extended the warranty of the LG NeON® 2 Black for an additional 2 years. Additionally, LG NeON® 2 Black can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. The rear of the cell used in LG NeON® 2 Black will contribute to generation, oust like the front; the light beam reņected from the rear of the module is reabsorbed to generate a great amount of additional power. Innovation for a Better Life Characteristic Curves North America Solar Business Team LG Electronics U.S.A. Inc 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: lg.solar@lge.com www.lgsolarusa.com Copyright © 2017 LG Electronics. All rights reserved. 01/01/2017 Innovation for a Better Life Electrical Properties (NOCT*) Module Maximum Power (Pmax) MPP Voltage (Vmpp) MPP Current (Impp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 236 30.8 7.67 38.0 8.20 * NOCT (Nominal Operating Cell Temperature): Irradiance 800W/m², ambient temperature 20 °C, wind speed 1m/s Electrical Properties (STC *) Module Maximum Power (Pmax) MPP Voltage (Vmpp) MPP Current (Impp) Open Circuit Voltage (Voc) Wshypi OjŃgmirg} Operating Temperature We|mqyq ]}wxiq `spxeki Maximum Series Fuse Rating 18.7 1,000 20 LG320N1K-A5 320 33.3 9.62 40.8 10.19 Mechanical Properties Cells Cell Vendor Mipp ^}ti Cell Dimensions # of Busbar Dimensions (L x W x H) Front Load Rear Load Weight Msrrigxsv ^}ti Junction Box Cables Glass Frame 6 x 10 LG Monocrystalline / N-type 161.7 x 161.7 mm / 6 inches 12 (Multi Wire Busbar) 1686 x 1016 x 40 mm 6000Pa 5400Pa 18 kg MC4 IP68 with 3 Bypass Diodes 1000 mm x 2 ea High Transmission Tempered Glass Anodized Aluminium Temperature Characteristics NOCT Pmpp Voc Isc 45 ± 3 °C -0.37%/°C -0.27%/°C 0.03 %/°C Module Fire Performance (USA) Product Warrerx} Output Warrerx} of Pmax IEC 61215, IEC 61730-1/-2 UL 1703 IEC 61701 (Salt mist corrosion test) IEC 62716 (Ammonia corrosion test) Type 2 12 years Linear warranty** ** 1) 1st year : 98%, 2) After 1st year : 0.55% annual degradation, 3) 25 years : 84.8% Dimensions (mm/in) Fire Rating (CANADA) Class C MivxmŃgexmsrw erh aevverx} Voltage (V) 10 1000W 600W 200W 800W 400W 6 2 8 4 0 10 30 20 40 15 35 25 5 Current (A) Temperature (°C) Isc Voc Pmax 140 100 20 60 -40 90 25 Isc, Voc, Pmax (%) ISO 9001 Power Tolerance (%) -40 ~ +90 0 ~ +3 * STC (Standard Test Condition): Irradiance 1,000 W/m², Ambient Temperature 25 °C, AM 1.5 * The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. * The typical change in module efŅciency at 200 W/m² in relation to 1000 W/m² is -2.0%. LG320N1K-A5 Short Circuit Current (Isc) LG320N1K-A5 40.00/1.5729.00/1.14 66.38 x 40 x 1.57 inch 8.0/0.3 3.0/0.1Detail Z 4.3/0.2 ØDetail Y 8.5/0.3 12.0/0.5Detail X Frame Cross-section 40.0/1.6 1000.0/39.4 Cable Length Junction Box 8-8.5*12.0/0.3*0.5 Mounting Holes [X view] (-) 8-Ø4.3/0.2 Grounding Holes [Y view] 16-8.0*3.0/0.3*0.1 Drain Holes [Z view] (+) 1016.0/40.0 976.0/38.4 105.0/4.1200.0/7.9300.0/11.8175.0/6.9 1086.0/42.81286.0/50.61686.0/66.4120 80 40 SEAN HATCH 09/12/17 SEAN HATCH 09/12/17 SEAN HATCH 09/12/17 SEAN HATCH 09/12/17 Business Stream Products Renewable and Solar Technology TÜV Rheinland PTL Photovoltaic Testing Laboratory 2210 South Roosevelt Street Tempe, Arizona 85282 Main Phone: 480-966-1700 Main Fax; 775-314-6458 Email: info@tuvptl.com TÜV Rheinland North America Holding, Inc. 1 Federal Street Boston, MA 02110 Main Phone: 617-426-4888 Main Fax: 617-426-6888 Member of TÜV Rheinland Group Attn: John Nagyvary nirac Inc. 1411 road ay lvd lbuquerque, 87102 Phone: +505 242 6411 Email: john.nagyvary@unirac.com Email: MWitt@us.tuv.com December 19, 2014 UL SU 2703 Fire Testing Completed Type of Equipment: PV Mounting System Model Designation: Unirac Roof Mount Test Requirement: UL Subject 2703, Issue  TÜV Rheinland File Number: L1-URC140731-RM TÜV Rheinland Project Number: URC140731 Dear Mr. Nagyvary,      the Unirac Roof Mount (RM) PV Mounting System has successfully completed fire testing according to the UL Subject 2703 with references from UL1703 rev. May 2014 standard. Congratulations on this achievement. The Unirac Roof Mount (RM) PV Mounting System has demonstrated compliance with a Class A Fire Rating when installed with the following Fire Types: x Type 1 x Type 2 x Type 3 Complete test results, including any necessary mitigation measures for the fire rating, can be found in report R1-URC140731-RM. This correspondence may be used as a Letter of Compliance (LOC) indicating the Unirac Roof Mount (RM) PV Mounting System has met the relevant system fire requirements. Sincerely, Mark Witt Engineering Manager TÜV Rheinland PTL, LLC SEAN HATCH 09/12/17  $XVVLH 8QLYHUVDO ,QWHUORFNLQJ - 5RRI 0RXQWLQJ %UDFNHW KWWSZZZDXVVLHURRILQJFRPMEUDFNHWKWP  8VH WKH - %UDFNHW WR PRXQW 6RODU 3DQHOV $LU &RQGLWLRQHUV 6ZDPS &RROHUV 5RRI :DONZD\V KH $XVVLH 8QLYHUVDO ,QWHUORFNLQJ - 5RRI 0RXQWLQJ %UDFNHWŠ ZDV LQYHQWHG E\ 2UODQGR *XDVWHOOD DW $XVVLH 5RRILQJ 7KLV VSHFLDO - %UDFNHWŠ LV GHVLJQHG WR ZRUN ZLWK *HUDUG DQG 'HFUD WLOH DQG VKDNH SDQHOV DQG RWKHU VWRQHFRDWHG VWHHO URRILQJ V\VWHPV ,W SURYLGHV D FOHDQ QROHDN ZHDWKHUSURRI LQVWDOODWLRQ RI D VWURQJ  JDXJH JDOYDQL]HG VWHHO 7KH 8QLYHUVDO - %UDFNHWŠ LV GHVLJQHG WR EH XVHG IRU PRXQWLQJ VRODU SDQHOV DLU FRQGLWLRQHU PRXQW URRI SLWFKHG VZDPS FRROHUV URRI ZDONZD\V VLJQV HWF WR WKH URRI $YDLODEOH WR FRQWUDFWRUV DQG KRPHFUDIWVPHQ 2UGHU \RXU VXSSO\ WRGD\ IRU \RXU QH[W SURMHFW ,QVWDOODWLRQ 'HWDLOV $OZD\V ORFDWH WKH 8QLYHUVDO - %UDFNHWŠ RYHU DQG DERYH ZKHUH WKH UDIWHU DQGRU [ [PP FRXQWHU EDWWHQ LV ORFDWHG $ PLQLPXP RI WKUHH IDVWHQHUV VKRXOG EH XVHG WZR  ZRRG VFUHZV DQG RQH G QDLO 7KH WZR VFUHZ IDVWHQHUV JR LQWR WKH UDIWHU WKURXJK WKH [ DQG RQH QDLO LQWR WKH [ SDQHO EDWWHQ 6HH LOOXVWUDWLRQ 3LORW KROHV KDYH WR EH GULOOHG ODUJH HQRXJK WR FOHDU WKH VFUHZV 6SDFH WKH 8QLYHUVDO - %UDFNHWVŠ HYHU\  PLQLPXP PP DFURVV WKH URRI 7KLV PD\ EH FKDQJHG WR VXLW WKH LWHP EHLQJ VXSSRUWHG 7KH 8QLYHUVDO - %UDFNHWŠ LV GHVLJQHG WR DFFRPPRGDWH DQ H[SRVHG [ RU [ PHWDO RU ZRRG SODQN 2WKHU EUDFNHW W\SH DWWDFKPHQWV FRXOG DOVR EH DWWDFKHG ,I H[WHULRU OXPEHU LV XVHG LW VKDOO EH D WUHDWHG W\SH OXPEHU 7KH OXPEHU VKDOO EH IDVWHQHG WR WKH 8QLYHUVDO - %UDFNHWŠ ZLWK DQ DSSURSULDWH VL]H PLQLPXP  VFUHZV ZLWK ZDVKHUV DQG QXWV DV QHHGHG ,OOXVWUDWLRQV  6HFXUH WKH 8QLYHUVDO - %UDFNHWŠ  )LW SDQHOV DURXQG - %UDFNHWŠ DQG VHFXUH DV QRUPDO  ,QVWDOO KRUL]RQWDO VXSSRUW PDWHULDO DQG VHFXUH WR - %UDFNHWŠ  $XVVLH 8QLYHUVDO ,QWHUORFNLQJ - 5RRI 0RXQWLQJ %UDFNHW KWWSZZZDXVVLHURRILQJFRPMEUDFNHWKWP  'LVFODLPHU 7KLV SURGXFW LV QRZ LQ LWV HOHYHQWK \HDU RI XVH DEVHQW DQ\ FRPSODLQWV UHJDUGLQJ OHDNDJH RU UHDFWLRQ WR ZLQG 7KHUH KDYH EHHQ QR FRPSODLQWV IURP FXVWRPHUV RU VRODU FRQWUDFWRUV QDWLRQZLGH /DERUDWRU\ ORDG WHVWLQJ KDV EHHQ SHUIRUPHG LQ 'HFHPEHU  7KLV EUDFNHW LV GHVLJQHG WR LQWHUORFN ZLWK D VWRQHFRDWHG VWHHO WLOH SDQHO URRI V\VWHP DFFRPPRGDWLQJ D ZLQG UHVLVWDQFH UDWLQJ RI XS WR  PSK 7KH EUDFNHW LV VWURQJHU WKDQ WKH WLOH DQG VHFXUHG ZLWK D PXFK PRUH GXUDEOH IDVWHQHU WKDQ HLWKHU WKH WLOH RU LWV ZRRG IUDPH  ZRRG VFUHZ LQWR WKH UDIWHU ,W LV LQVWDOOHG TXLFNO\ VDYLQJ WLPH DQG H[WUD PDWHULDO ZLWKRXW WKH QHHG WR LQVWDOO D SROH W\SH VWDQGRII ZLWK IODVKLQJ DQG DQ H[WUD SDQHO $OVR WKH - %UDFNHWŠ KDV WKH DGGHG IHDWXUH²LWV QROHDN LQWHUORFNLQJ DELOLW\ /RDG 7HVWV -%UDFNHW 7HVW 5HVXOWV 6800$5< 3') )LOH -%UDFNHW 7HVW 5HVXOWV )8// '2&80(17$7,21 3') )LOH ,I \RX QHHG $GREH $FUREDW 5HDGHU GRZQORDG LW IUHH QRZ &OLFN WKH LPDJHV EHORZ IRU IXUWKHU H[SODQDWLRQ RI SKRWR $XVVLH 8QLYHUVDO - %UDFNHWŠ 4XRWH 5HTXHVW )RUP 5HTXHVW D TXRWH IRU SXUFKDVLQJ DQGRU LQVWDOOLQJ WKH $XVVLH 8QLYHUVDO - %UDFNHWŠ EHORZ SEAN HATCH 09/12/17 J Bracket Load Test Date: 12.19.2008 Product Name: Gerard Tile over batten Manufacturer: Gerard Roofing Technologies Coverage Area: 14.375" x 43.75" Gauge: 26 ga. Installation Description: Tile fastened to batten with (6) screws Batten fastened to counter batten with (1) screw per intersection J Bracket fastened to batten with (3) screws Applied Load (lb) J Bracket Deflection (in) Test #1 Test #2 Test #3 25 0.023 0.040 0.028 50 0.046 0.074 0.052 75 0086 0115 008475 0 .086 0 .115 0 .084 100 0.131 0.156 0.124 125 0.203 0.185 Failure Mode Panel Buckled Panel Buckled Panel Buckled Maximum Load (lb) 118 133 127 Average Load (lb) 126 120 160 200 d (lb) Load vs Deflection 0 40 80 0.000 0.050 0.100 0.150 0.200 0.250 LoadDeflection (in) Test #1 Test #2 Test #3 Test #1 Set Test #2 Set Test #3 Set SEAN HATCH 09/12/17 J Bracket Load Test Date: 12.19.2008 Product Name: Gerard Tile over batten and Insulform Manufacturer: Gerard Roofing Technologies Coverage Area: 14.375" x 43.75" Gauge: 26 ga. Installation Description: Tile fastened to batten with (6) screws. Batten fastened to counter batten with (1) screw per intersection. J Bracket fastened to batten with (3) screws. Insulform Applied Load (lb) J Bracket Deflection (in) Test #1 Test #2 Test #3 40 0.085 0.057 80 0.097 0.122 0.090 120 0152 0130120 0 .152 0 .130 160 0.205 0.172 0.180 200 0.202 0.233 Failure Mode Bracket Buckled Bracket Buckled Bracket Buckled Maximum Load (lb) 207 226 235 Average Load (lb) 223 75 100 125 d (lb) Load vs Deflection 0 25 50 0.000 0.050 0.100 0.150 0.200 0.250 LoadDeflection (in) Test #1 Test #2 Test #3 Test #1 Set Test #2 Set Test #3 Set SEAN HATCH 09/12/17 GET OFF THE ROOF FASTER THAN EVER BEFORE SMSOLAR MOUNT SOLARMOUNT defined the standard in solar racking. New enhancements are designed to get installers off the roof faster than ever before. Components are pre-assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. OPTIMIZED COMPONENTS • VERSATILITY • AVAILABILITY • DESIGN TOOLS ROOF MOUNT SYSTEMS NEW ENHANCEMENTS ELIMINATE THE GROUNDWIRE FROM YOUR SOLARMOUNT ARRAY LOSE THE COPPER & LUGS INTEGRATED GROUNDINGPOWERED BY: UL2703 BONDING & GROUNDING SYSTEM FIRE CLASSIFICATION CLASS A - TYPE 1, 2, 3 & 10 MODULES MECHANICAL LOADING LISTED UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY PROTECT YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN OPTIMIZED COMPONENTS INTEGRATED BONDING & PRE-ASSEMBLED PARTS Components are pre-assembled and optimized to reduce installation steps and save labor time. Our new grounding & bonding process eliminates copper wire and grounding straps or bonding jumpers to reduce costs. Utilize the microinverter mount with a wire management clip for an easier installation. VERSATILITY ONE PRODUCT - MANY APPLICATIONS 4XLFNO\ VHW PRGXOHV ˊXVK WR WKH URRI RU DW D GHVLUHG WLOW DQJOH &KDQJH PRGXOH orientation to portrait or landscape while securing a large variety of framed PRGXOHV RQ ˊDW ORZ VORSHG RU VWHHS SLWFKHG URRIV $YDLODEOH LQ PLOO FOHDU DQG GDUN DQRGL]HG ˉQLVKHV WR RXWSHUIRUP \RXU SURMHFWV ˉQDQFLDO DQG DHVWKHWLF DVSLUDWLRQV AVAILABILITY NATIONWIDE NETWORK Unirac maintains the largest network of stocking distributors for our racking VROXWLRQV 2XU SDUWQHUV KDYH GLVWLQJXLVKHG WKHLU OHYHO RI FXVWRPHU VXSSRUW DYDLODELOLW\ DQG RYHUDOO YDOXH WKHUHE\ SURYLGLQJ WKH KLJKHVW OHYHO RI VHUYLFH WR users of Unirac products. Count on our partners for fast and accurate delivery to meet your project objectives. Visit Unirac.com for a list of distributors. AUTOMATED DESIGN TOOL DESIGN PLATFORM AT YOUR SERVICE &UHDWLQJ D ELOO RI PDWHULDOV LV MXVW D IHZ FOLFNV DZD\ ZLWK 8%XLOGHU D powerful online tool that streamlines the process of designing a code FRPSOLDQW VRODU PRXQWLQJ V\VWHP 6DYH WLPH E\ FUHDWLQJ D XVHU SURˉOH DQG recall preferences and projects automatically when you log in. You will enjoy the ability to share projects with customers; there’s no need to print UHVXOWV DQG VHQG WR D GLVWULEXWRU MXVW FOLFN DQG VKDUH SMSOLAR MOUNT BANKABLE WARRANTY $V D +LOWL *URXS &RPSDQ\ 8QLUDF KDV WKH ˉQDQFLDO strength to back our products and reduce your risk. +DYH SHDFH RI PLQG NQRZLQJ \RX DUH UHFHLYLQJ SURGXFWV RI H[FHSWLRQDO TXDOLW\ 62/$502817 is covered by a 10-year limited product ZDUUDQW\ DQG D \HDU OLPLWHG ˉQLVK ZDUUDQW\ TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues LQ UHDO WLPH $Q RQOLQH OLEUDU\ RI GRFXPHQWV LQFOXGLQJ HQJLQHHULQJ UHSRUWV VWDPSHG OHWWHUV DQG WHFKQLFDO GDWD VKHHWV JUHDWO\ VLPSOLˉHV your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO FHUWLˉFDWLRQV IRU   DQG 2+6$6  ZKLFK PHDQV ZH GHOLYHU WKH KLJKHVW VWDQGDUGV IRU ˉW IRUP DQG IXQFWLRQ 7KHVH FHUWLˉFDWLRQV GHPRQVWUDWH RXU H[FHOOHQFH DQG FRPPLWPHQW WR ˉUVW FODVV EXVLQHVV SUDFWLFHV INTEGRATED BONDING MIDCLAMP INTEGRATED BONDING SPLICE BAR INTEGRATED BONDING MICROINVERTER MOUNT w/ WIRE MANAGEMENT INTEGRATED BONDING L-FOOT w/ T-BOLT NEW ENHANCEMENTS R © PUB - 150101 - DIGITAL UPDATES SEAN HATCH 09/12/17