Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14100015
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10180 CARMEN RD CONTRACTOR: SOLAROPOLY INC DBA PERMIT NO: 14100015 SOLAR UNIVERSE OWNER'S NAME: RUNE JENSEN & CAROLINE LIM P O BOX 110536 DATE ISSUED: 10/02/2014 OWNER'S PHONE: 4157063772 CAMPBELL, CA 95011 PHONE NO: (408) 579-1700 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL ❑ INSTALL ROOF MOUNTED SOLAR (18 MODULES) (4.95 License Class Li..'3212— KW) Contractor a YD Date 1012,114 I hereby affirm that I am li nsed u der the provisions of Chapter 9 (commencing with Section 7000) Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $28000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35709014.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITfIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the by: � N % Date: Q granting of this permit. Additionally, the applicant understands and will comply Issued withall non-poin ource re ulations per th upertino Municipal Code, Section 9.18. /J/RE-ROOFS: SignatureDateW� All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ NER-B ILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I. as owner of the property, or my employees with wages as their sole compensation, �� itl do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertin Municipal de, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this the Health & Safety Code, nd 34. Z Owner or authorized agentDate:/ permit is issued. HUCTIOENDING I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONS AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address 1 certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CUPERTINO /yr000i5 ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building a<7cupertino.orq AE PROJECT ADDRESS r I// APN#0 3,5O q 0/11 OWNER NAME //cne-(/enje-o PHONE u/ 1) 74,/, E-MAIL ha "Au P GNSG �j STREET ADDRESS ((, t! CITY, STATE, ZIP r / nO Cr -/ Y0131� FAX CONTACT NAME a rc 1Q PLIONE o 79 -/ -&; E-MAIL c� arc��z Sa%run;'vc . STREET ADDRESS -3 s/v�� CITY, STATE, ZIP r FAX ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Sa1GIy�S r LICENSE NUMBERLICENSE °l 3a8t3a TYPE C, 610 BUS. LIC # COMPANY NAME �I ^ f v� / �•t E-MAIL Q li �i YCG FAX r�1 STREET ADDRESS/J ✓ CITY, STA ,ZIP f PHONE Wz T�� ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT IN FLOOD ZONE ❑ Yes ❑ NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION El SOLAR WATER HEATING El OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS (COMMERCIAL ONLY): TOTAL VALUATION: O DESCRIPTION OF WORK (. re?/, a� r /)� 11 RECEIVED BY: By my signature below, I certify to each of the following: 1 m the property own or authorized agent to act on the property owner's behalf. I have read this application and the information I have provid is correct ave r the De ory with all applicable local ork and verify it is accurate. I agree Np ordinances and state laws relatbuildin onstruc . I aut Ize repr entatives o upertino to enter theabove-identifiefor inspection purposes. Signature of Applicant/Agent/ Date: � SUPPLEME AL INFO TION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER a F' Y ❑ EXPRESS U y, ❑ STANDARD V a ❑ LARGE ❑ MAJOR PVApp201 Ldoc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR — BUILDING DIVISION ADDRESS: 10180 Carmen Road DATE: 10/02/2014 REVIEWED BY: Sean APN: 131'#: 'VALUATION: $28,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR -RE WORK Install roof mounted solar 18 mod6les 4.95 k _ SCOPE NOTE: This estimate does not include jeer due to other Departments (i.e. Planning, Public Works, Pire, Nanitaty Sewer utstrtct, acnoot T..0-0 ..e.. 1 Ti.— fno _ Anand nn /ho nrntiw.innn, and nro nnty nn octii»No_ rantart tho Dont fnr addn'l infn_ FEE ITEMS (Fee Resolution 11-053 E . 7'1!13) - -- - - - 1'ltut�b. Non r LiOrhtrr - - NOTE: This estimate does not include jeer due to other Departments (i.e. Planning, Public Works, Pire, Nanitaty Sewer utstrtct, acnoot T..0-0 ..e.. 1 Ti.— fno _ Anand nn /ho nrntiw.innn, and nro nnty nn octii»No_ rantart tho Dont fnr addn'l infn_ FEE ITEMS (Fee Resolution 11-053 E . 7'1!13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 =# $236.00 Alternative Energy System I PHOTOYRES Photovoltaic System Suppl. PC Fee: C) Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee -0 Reg. Q 0' p.p I�rs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 G) Work Without Permit? © Yes 0 No $0.00 Advanced Planning Fee. $0.00 Select a Non -Residential Building or Structure G) O A Strong Motion Fee: IBSEISMICR $3.64 Select an Administrative Item BldgStds Commission Fee: IBCBSC $2.00 SUBTOTALS: $5.64 $236.00 TOTAL FEE: $241.64 Revised: 08/20/2014 16'-0" 30j RAFTERS 2x6D.1. LEGEND - 241N O.C. RESIDENTIAL 4950W GRID -TIED ® MOUNTING ROOF MOUNTED PV SYSTEM ELECT PANEL CVL— COPY I i ov VENT DISH Fc� CHIMNEY sLSKYLIGHT I i SUNEYE°-� ,. FRONT OF HOUSE COMP SHINGLE I COMMUNJII.TVELOPMENT DEPARTMENT BUI DIY pDf. `BION CUPERTINO )=VED This set oi plans acid specificatto S MU T tk)ke at the changenr aliel CHECKED of DA3m1. NC DATE therefrom, withoutl pproval from the Building Official. I — — — — — — — e 'tamping oTthis plan and specifications SHALL NOT ... _..- _ _ _ be held to permit o to be an r w;�l of the violation DEPT, ^f an rovisior�, ny Cih State Law. MAIN SERVICE: BY — t ~ ; � G SATE /D 200A PANEL — o n. 6 ft. 1 ort. ---- 20 n. 200A MAIN CB GAS GATE CONTRACTOR: SOLAROPOLY, INC. 3350 SCOTT BLVD, BLDG. 53 SANTA CLARA, CA 95054 (408) 426-4911 I U I UU VQI I I ICI 1 INU II I� ARRAY PANELS AZIMUTH TILT _ IMPL'ANCE 1 18 9 R MODULE: QTY 18 LG SOLAR IJW75S1C-B3 now INVERTERS: QTY 18 ENPHASE M250-60-2LL-S22 RACKING: QTY 9 IRON RIDGE F AILS 14FT MOUNTING: SERVICE:- ' QTY 30 IRON RIDGE FLASH FOOT USE EXISTING ELECT SERVICE PANEL CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartung_jensen@yahoo.com APN:35709014 CITY OF CUPERTINO MECHANICAL STEFFAS Jensen, Rune - ENGINEERING.vsd STEFFAS Last Edited 10/2/2014 TABLE 1 - MECHANICAL LOAD CALCULATIONS Load Factors: 10180 CARMEN RD Weight of Panels 40.0 lbs X 18 = 719.31bs Weight of Inverters 3.51bs X 18 = 63.01bs Weight ofBOS 3.21bs X 18 = 57.61bs Total Weight of System = 839.9 1 b Number of Points= 30 Points Load/Point =1 28.00lbs /Poin Array Size (sqf) 18.06 x 18 = 325.0 sqf Load (lbs/sqf) = 2.58 lbs/sqf MOUNTING DETAIL 71,115 E06E 70WARDS BOO: AWA (12.00) (3.00) -- -- (12-00) �, f (1281 COLLAR every othi RESIDENTIAL 4950W GRID -TIED ROOF MOUNTED PV SYSTEM MOUNTING METHOD (D TRUSS DETAIL CONTRACTOR: SOLAROPOLY, INC. 3350 SCOTT BLVD, BLDG. 53 ." NI VERSE SANTA CLARA, CA 95054 (408) 426-4911 m ;sm C? T; n o -8S 2xCD.F: 7 0 C O -E M n CO — txis ng I -w wLQUE CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartungJensen@yahoo.com APN:35709014 C11rrL17wll1/1,Z:akyro� SHEET MECH TABLES ENG: STEFFAS SALES: CHRIS SHEA DATE: 8 -SEP -14 SHEET 2 OF 6 Jensen, Rune - ENGINEERING.vsd STEFFAS Last Edited 10/2/2014 l I NOTES 1. WIRE AMPACITY CALCULATIONS ARE ON SHEET 4 2 PER NEC 705.12 (D) (2) THIS SWITCHBOARD IS CAPABLE OF BACKFEEDING THE PV SOURCE BECAUSE THE TOTAL SOURCE TO THE PANEL BOARD DOES NOT EXCEED 120% OF THE BUS BAR AMPACI TY. LIMIT: 200A X 1.2 = 240A SOURCE: 200A+15A+15A = 230A ENPHASE INTERCONNECT CABLE 10 AWG THWN-2 L1,L2, N 10 AWG THWN-2 L1,L2,N RESIDENTIAL 4950W GRID -TIED QTY 9 LG LG275S1C-B3 FY 9 ENPHASE ? 50-60-2 L L -S22 ROOF MOUNTED PV SYSTEM ----=---------------_----_ 11 8AWG CONTINUOUS GROUND 200A RATED PANEL 15A Imax =9A 15A Imax =9A SOURUNIVERSET. Jensen, Rune - ENGINEERING.vsd UTILITY METER MAIN BREAKER 200A 2 3 CONTRACTOR: SOLAROPOLY, INC. 3350 SCOTT BLVD, BLDG. 53 SANTA CLARA, CA 95054 (408) 426-4911 MODULE SPECIFICATIONS: LG SOLAR LG275S1C-B3 PMAX: 750 WATTS VM P: 31.7 V IMP: 8.68 A VOC: 38.7 V ISC: 9.26 A MAX SERIES FUSE: 15A MAX SYSTEM VOLTAGE: 1000VDC DIMENSIONS (IN): 64.57 X 39.37 X 1.38 WEIGHT: 36.96 LBS. INVERTER SPECIFICATIONS: ENPHASE M250-60-2LL-S22 IEEE -929, IEEE -1547, UL 1741 MAX DC INPUT VOLTAGE: 48VDC MAX DC INPUT CURRENT: 10.5 AMPS MAX DC SHORT CURRENT: 15 AMPS MAX AC OUTPUT POWER: 25OW NOM OUTPUT CURRENT: 1.OA NOM VOLT RANGE: 240V/ 211V -264V CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartung Jensen@yahoo.com APN:35709014 STEFFAS ARRAY ff PANEL WLITH TILT 1.otg�f g 15deg GU �� Y• jE ".01J1Ft .f.N RE � R �1eWed BY PLABELS C PHOTOVOLTAIC SYSTEM AC DISCONNECT NOMINAL AC OPERATING VOLTAGE: 240 VAC RATED AC OUTPUT CURRENT: 18 AMPS CAUTION SOLAR CIRCUIT CITY OF CUPERTINO SHEET- THREE -LINE DIAG ENG: STEFFAS SALES: CHRIS SHEA DATE: 8 -SEP -14 SHEET 3 OF 6 Last Edited 9/12/2014 THESE AMPACITY CALCULATIONS REPRESENT THE MAXIMUM NUMBER OF MODULES PER STRING NOT THE ACTUAL NUMBER OF MODULES INSTALLED. THUS PROVIDING MORE THAN MINIMUM AMPACITY MARGIN ON MOST INSTALLATIONS. Ampacity Calculations for: 10180 CARMEN RD Wiring Location: Inverter to Panel (Alternating Current) All calculations show minimum sizing for ampacity Actual wire sizing may be larger for voltage drop or other factors All calculations are according the the 2010 CEC/2008 NEC Initial Input Values Inverter Continous AC ouput (Watts) 250 Minimum Operating Voltage 240 Watts Volts Amps 250 / 240 = 1.0 Inverter Continious AC Amps Number of circuits Minimum overcurrent device Overcurrent device rating NEC 690.8 (B) SIZE AWG # I 10 l Chosen Conductor Type THHN, THWN-2, RHW-2 or USE -2 Conductor Deratina 1.00 1.00 X F__97 = 9.0 9.00 X 125% = 11.2 F15-001 OK NEC 690.31 (C) ref (NEC 310.16) Conductor 90°C Ampacity 30 Conduit Fill Derating 30.00 X 1.00 = 30.0 Temperature Derating °F 78--86 30.00 X 1.00 = 30.0 Ampacity vs. Overcurrent Dev Conductor Ampacity Check Conductor to Overcurrent Check 30.00 2: 11.20 OK 30.00 >- 15.00 OK CONTRACTOR: SOLAROPOLY, INC. G. SOL4� NI VERSE 3350 SAN A CLARA,SCOTTDCA 9b 54 3 (408) 426-4911 Jensen, Rune - ENGINEERING.vsd a RESIDENTIAL 4950W GRID -TIED ROOF MOUNTED PV SYSTEM CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartungJensen@yahoo.com APN:35709014 CITY OF CUPERTINO SHEET. ELECT TABLES ENG: STEFFAS SALES: CHRIS SHEA DATE: 8-SEP44 SHEET 4 OF 6 STEFFAS Last Edited 9/12/2014 JANICE AVE m z 0 RESIDENTIAL 4950W GRID -TIED ROOF MOUNTED PV SYSTEM J C I SERVICE ,I - - - - — GAS - - GATE CONTRACTOR: SOLAROPOLY, INC. 3350 SCOTT BLVD, BLDG. 53 SOL4RUNIVERSE SANTA CLARA, CA 95054 (408) 426-4911 ;�-ING 9uilding Depprtment .;CT 0 i 2014 REVIEwEu hvR CUUC :O i1nP�'�,NCE rev Pwed 8y .r CUSTOMER: RUNE JENSEN SHEET. 10180 CARMEN RD - -- - CUPERTINO, CA 95014 ENG.- (415) NG:(415) 706-3772 SALES: Rune_hartung_jensen@yahoo.com DATE: APN:35709014 CITY OF CUPERTINO SITE PLAN STEFFAS Jensen, Rune - ENGINEERING.vsd STEFFAS Last Edited 9/12/2014 NOTES: 1. THE ENTIRE PHOTOVOLTAIC SYSTEM SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE 2011 EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) ARTICLES 690 AND 250, 2013 CALIFORNIA ELECTRICAL CODE (CEC), FIRE MARSHAL CODE (NFPA) 11 AND LOCAL ELECTRICAL CODES CURRENTLY BEING ENFORCED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2. THE PHOTOVOLTAIC SYSTEM SHALL HAVE CONDUCTORS BONDED TO GROUNDING BUS INSIDE POWER INVERTER AS REQUIRED BY THE 2008 NEC 690.41 SYSTEM GROUNDING AND 690.41 POINT OF SYSTEM GROUND CONNECTION. 3. A GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE SHALL BE INTEGRATED WITH THE AC/DC POWER INVERTER SO AS TO MAINTAIN COMPLIANCE WITH NEC 690.5(A) 4. ALL DC POWER CIRCUITS ROUTED VIA BUILDING INTERIOR SHALL BE COMPLETELY CONTAINED BY METALLIC RACEWAYS OR ENCLOSURES FROM THE POINT OF PENETRATION TO THE FIRST READILY ACCESSBILE MEANS OF DISCONNECTION (NEC 690.31) 5. WIRE SIZES AND CALCULATED VALUES ARE NOMINAL AND SHALL BE VERIFIED OR CONFIRMED AS COMPLYING WITH ARTICLE 310 OF THE 2008 NEC. ALL AMPACITY CALCULATIONS SHALL BE VERIFIED WITH RESPECT TO THE CONDITIONS ON-SITE. 6. ALL CONDUIT SIZES SHALL SATISFY THE REQUIREMENTS PRESCRIBED PER CHAPTER 9, TABLE 1.0 ANNEX C (TABLE C.1) OF THE 2008 NEC. LARGER DIAMETER CONDUIT MAY BE UTILIZED SO AS TO FACILITATE EASE OF CONDUCTOR INSTALLATION. 7. THE INSTALLER SHALL SEAL ALL CONDUIT PENETRATIONS THROUGH WALL AND FLOORS WITH FIRE RETARDANT MATERIALS. ALL PENETRATIONS ARE TO BE SEALED AND PATCHED ACCORDINGLY, 8. THERE SHALL BE LABELS OR MARKINGS PRESENT WHEN THE FOLLOWING SOLAR COMPONENTS PRESENT: A. DC DISCONNECT MEANS (NEC 690.17) B. DC POWER SOURCE (NEC 690.53) C. INTERACTIVE SOLAR SYSTEM POINT OF CONNECTION (NEC 690.54) 9. 10AWG USE -2 OR RHW-2, 90°F CONDUCTORS CAN GENERALLY BE UTILIZED FOR SOLAR MODULES WITH AND ISS RATING OF 9.6A OR LESS WHEN PROTECTED BY A MAXIMUM OF A 15A FUSE OR BREAKER. 10. 8AWG CONDUCTOR OR LARGER SHALL BE UTILIZED FOR GROUNDING AND BONDING OF SOLAR SYSTEM. IF THE CONDUCTOR IS INSULATED, IT SHALL BE GREEN. SOIARUNIVERSE CONTRACTOR: SOLAROPOLY, INC. 3350 SCOTT BLVD, BLDG. 53 SANTA CLARA, CA 95054 (408) 426-4911 RESIDENTIAL 4950W GRID -TIED ROOF MOUNTED PV SYSTEM BONDING FITTING FOR CONDUIT, JUNCTION BOXES AND ELECTRICAL ENCLOSURES SHALL BE UL COMPLIANT. 12. ALL BARE METAL CONDUIT RACEWAYS IN EXPOSED OR EXTERIOR LOCATIONS SHALL BE EITHER RGS OR PAINTED EMT. 13. ALL ELECTRICAL PANEL BOARDS ARE TO BE A MINIMUM OF 600V AC RATED, NEMA 3R STAINLESS STEEL ENCLOSURES WITH LOCKABLE SWINGING COVERS. 14. ALL UNDERGROUND RACEWAYS SHALL UTILIZE SCHEDULE TYPE 40 PVC UNLESS OTHERWISE NOTED ON THE PLANS. 15. ALL IN -GROUND PULL BOXES AND OR JUNCTION BOXES SHALL BE PROPERLY FASTENED AND EQUIPPED WITH FLUSH STYLE CONCRETE LIDS. 16. SOLAR MODULES SHALL COMLY WITH THE CRITERIA LISTED UNDER UL 1703. 17. ALL SOLAR INVERTERS SHALL BE CERTIFIED WITH THE CALIFORNIA ENERGY COMMISION AND UL 1741 LISTED UTILITY INTERACTIVE SIZE AND RATINGS AS NOTED ON THE PLANS. 18. SOLAR RACKING SHALL COMPY WITH THE CRITERIA LISTED UNDER UL 2703. 19. SOLAR EQUIPMENT SHALL BE UL COMPLIANT OR EQUIVALENT. 20. SOLAR GROUNDING AND BONDING SHALL COMPLY WITH THE LISTED INSTALLATION INSTRUCTIONS FOR THE PV MODULES AND UL1703. 21. THE INSTALLER SHALL BE RESPONSIBLE FOR PATCHING AND PAINTING WALLS SO AS TO MATCH EXISTING FINISHES. PATCH WALL VINYL IF PRESENT. PATCH AND PAINT AROUND NEW DEVICES AND BLANK PLATES IN EXISTING JUNCTION BOXES AS REQUIRED TO MATCH EXISTING FINISHES. ALL ELECTRICAL RATINGS MUST BE MAINTAINED REGARDLESS OF MEANS OF AESTHETIC RESTORATION. CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartung_jensen@yahoo,com APN:35709014 SHEET: , t, vol� STEFFAS 10 SALES: avS� DATE: 8 -SEP -14 CITY OF CUPERTINO CUSTOMER: RUNE JENSEN 10180 CARMEN RD CUPERTINO, CA 95014 (415) 706-3772 Rune_hartung_jensen@yahoo,com APN:35709014 Jensen, Rune - ENGINEERING.vsd STEFFAS Last Edited 9/12/2014 SHEET: NOTES ENG: STEFFAS CHRIS SHEA SALES: DATE: 8 -SEP -14 SHEET 6 OF 6 Jensen, Rune - ENGINEERING.vsd STEFFAS Last Edited 9/12/2014