Loading...
13060135 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10878 SYCAMORE CT CONTRACTOR:DE SWANSON PERMIT NO: 13060135 CONSTRUCTION OWNER'S NAME: DAVE MEHUYS 2433 CORY AVE DATE ISSUED: 12/04/2013 OWNER'S PHONE: 4087331617 SAN JOSE,CA 95128 PHONE NO:(408)891-0742 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL �� G - LT ADD BALCONY,CHANGE ROOF LINE, REMODEL 182 SQ License ClassLie.# FT Contractor 5 W 1�i�SJ �/ Date �'Z -7 0i y IN MASTER LIVING ROOM, INSTALL RECESSED LIGHT IN I hereby affirm that I am licensed under the provisions of Chapter 9 AREA 10 LIGHTS AND 4 SWITCHES,ADD FLOOR (commencing with Section 7000)of Division 3 of the Business&Professions HEATING Code and that my license is in full force and effect. REVISION#1-CHANGE DETAILS OF RAILING SYSTEM-ISSD OTC I hereby affirm under penalty of perjury one of the following two declarations: 5/28/2014 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:34257036.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHI SYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAY AST CALLED INSP 'CTI N. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses whichPitionally, ay accrue against said City in consequence of the -5 2 6 /!/ granting of this permit the applicant understands and will comply Issued by: Date: with all non-point s rcelations per the Cupertino Municipal Code,Section 9.18. 1�S"`Z(i i fr RE-ROOFS: Signature -' Date_ _ / All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's license Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sea 7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cup Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Seetions 5 5533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: Dater permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18, Signature Date CONSTRUCTION PERMIT APPLICATION Is COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333 • buildinqCa)cupertino.org ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS APN# 1 cc,m r. G 10 .� t OWNER NAME n I, In ^^��I� _/C PHONE TMAIL _T_ STREET ADDRESS CITY, STATE,ZIP FAX CONTACT NAME PHONE E-MAIL STREET ADDRESS CITY,STATE, ZIP FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME! �� LICENSE NUMBER ������ LICENSE TYPE BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NA ME E-MAIL FAX STREET ADDRESS CITY.STATE,ZIP PHONE DESCRIPTION OF WORK a`? „) r C /C ✓ r, / I I"I S EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODELAREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ATTACH DWELLING UNITS. IS A SECOND UNIT YES SECOND STORY ❑YES BEING ADDED? ONO ADDITION? ❑NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY: TOTAL VALUATION: PLANNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO By my signature below,I certify to each of the Ilowing: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have prov` e is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b In struction, I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agenc Date: 2 �— 2U� I SUPPLEMENT L INFORMATION REQUIRED M.AK HECKTYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply for demolition permit forOVER-THE-COUNTER El BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of build' permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure El STANDARD El PUBLICWORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_201 Ldoc revised 06/21/11 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10878 SYCAMORE CT CONTRACTOR:-�)i BE PERMIT NO:13060135 W_T A ED OWNER'S NAME: DAVE MEHUYS v(rLSd-V DATE ISSUED: 12/04/2013 OWNER'S PHONE: 4087331617 worn bf.- PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL 11 License Class Lic.# ?7_� 6& S t I ADD BALCONY,CHANGE ROOF LINE,REMODEL 182 SQ L'' ✓ ,I�j G.� FT J 2. - �/ lcs� Contractor /,� Date IN LIVING ROOM,INSTALL RECESSED LIGHT IN I hereby affirm that I am licensed under the provisions of Chapter 9 MASTER (commencing with Section 7000)of Division 3 of the Business&Professions AREA 10 LIGHTS AND 4 SWITCHES,ADD FLOOR Code and that my license is in full force and effect. HEATING I hereby affirm under penalty of perjury one of the following two declarations: 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$250 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:34257036.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DA=AST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against Iiabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point so a regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date/Z All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). t have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equi "t or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay ea Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cu rtino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections,, 5,2 533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: /� Date: permit is issued. All I certify that in the performance of the work for which this permit is issued,l shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against Iiabilities,judgments, costs,and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 6�S'�U �,�+n„v,� �� DATE: -/7 3 REVIEWED BY: APN: BP#: 30a *VALUATION: $ ,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION 1GENRES USE: I PERMIT TYPE: WORK f0c1 le r SCOPE Elec.Plan Check 0.0 hrs $0.00 Elec.Permit Fee: IEPERMIT Other Elec.Insp. 0.0 hrs $45.00 NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). Theseees are based on the prelimina information available and are only an estimate. Contact the Dept-for addn'1 info. FEE ITEMS (Fee Resolution 11-053 E�. 7f %1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Balcony Addition Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 $733.00 1BALCONYAD PME Plan Check: $0.00 = s.f. Remodel,Other Permit Fee: $0.00 $400.00 IREMRESOTH Suppl. Insp.Fee-.0 Reg. Q OT 0.0 hrs $0.00 ® Electrical PME Unit Fee: $0.00 $45.00 1BREMRECEP Recep/Switch/Outlets PME Permit Fee: $45.00 10 # Electrical Cou."iP.- tion 'ax; ' $67.00 IBREMF'IXT Fixtures,Lighting Administrative Fee: IADMIN $42.00 Work Without Permit? ® Yes Q No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential E) Travel Documentation Fee: ITRAVDOC $45.00 Building or Structure i Strong Motion Fee: 1BSEISMICR $2.50 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $135.501$1,245.001 TOTAL FEE: 1 $1,380.50 Revised: 04/29/2013 CONSTRUCTION PERMIT APPLICATION h COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE •CUPERTINO, CA 95014-3255 VLp (408) 777-3228 • FAX (408) 777-3333• buildinmeculaertino.org ,� CUPERTINO ❑ NEW CONSTRICTION [-IADDITION EgAL`rERATION 1 TI ❑ REVISION 1 DEFFR,RF,.D ORIGINAL PERMIT r1 PRcn,l:rr.v>DREssI��'� CA vy10Yt C�-� APx k _ Z — 5-7_ 0 3� OW'JER NA\II}^��t Q� �4 Da-e �f w, PHO\'f 7r:A�atein- me-IV)Ltq-s ,Ir,)rp VI_ > }/l V S4Q3--73--3-) (.-,77 ��e C� r_ J STRFLT ADDRESS 1 C),87 G is m 6rC c•ITY, STATF,7IP FAX ( ����� , ee CU tt�^^�r� O (2 f CONTACT ?:1AIE l.�U l��� rupN[ 4�J �(Drrp �{8 ( E-ALAIL I ttU 1/ll(�GCG�d W —Gu�t ')q C(J vn STRETT ADDRESSI � C�O�� !`If v r C!TY,STATE, 7)P C,rye V� .� qn ` x µTER (1A1T'FR-riCllf)FR f�❑BONA-,,TFR/AG NT V❑ CONTRACTOR ❑COh-TRAC70RR.A�GFNT ❑ ARCHITECT 7❑l ENGLNFER ❑ Dsivrl.OPF..R ❑ TT,."Ni CONTRACTOR NAMF I.ICENSE NUMBER LICENSE TYPE HUS,L C s CONIPAN'Y N, 7E L-MAIL FAX STREET.ADDRESS -`.__..._.. C11 Y,STATE,ZIP PHONE AR A`TES'"r!E'N`INEE �At<tE 1 (Q LICENSE NUMBER � Ri:s I.IC COMPANY NAME J r-ASAI'. FAX STREET ADDRESS CI T Y,STATF,ZIP PHONE DESCRIPTION OF WORK aQco C �'�-fi o- c4 a- 4,5, EXiS3'I.SCi LUE PROPOSED USE, CONSTR.TYPE ! x STORIES f � t;sly: I N11,E ()CC. SQ F?'_ vA1 u:,Tiov isi 1 EXISIG NESS'FLOOR DEASO 'OTAI. AREA ARCA N/A_ AREA I(J/A- '4T-,T AR;:A . BATHROOM KITCHEN 1 OTHER RE.S10DELARFA RrFNMDEL.AREA �(� - ( RL`41oD[t..ARFA PORfH AREA D __A ECK ARF.A� Rr. GARAGE A ��j�� iOT:AL UEC'k:.���OACH AAEA : DEThCFi gATTACH I l C DWELLING L�':TS IS A SECOND UNIT �[]�YF:S SECON D STORY []YES ' BEING ADDED? '0:.0 ADDITION? E \0 -RF-APPLICATION' ;3�TS IF YES MOVIDE:Copy of IS THE BLDG AN ❑YI-S R1iCFIVFD HY: I-AINNING ADPL,' E)NO PLANNFNG APPROVAL L .F ,F..R EICELER 11011E? O By my signature below,t certify to each of the fol oxinR: I am the property orvncr or authorized agent to act on the property uwner s behaif. l have read this application and the inforniation 1 have pr ided is c acct. nave read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bt'di ucti 1 autho ' re reSentativesofCuperti to enter tlhc above-idem icd prepertm °or inspection purposcs. Signature of Applicant/Agent: _. __ (L { _ ate: S01)ITE!v-IE;N T'AT,INFORNtATION .QUIRE.[ P1..4y CIIECICTYPE ROUTING SLIP Nets-SFD or Multif unily d,�vclliugs: Apply fDr demolition hermit for ----- ❑ OVER-ME-COUNTER ❑ BUILDING PL4N RENIM existing building(s). Demolition pe-mii is required prior to issuance of buildin, permit for new buildin;, ❑ EXPRESS ❑ PLANNING PLAN RE%IFAV _CumHtercial Bides: Provide a completed hazardous,laterials Discloser; ❑ STANDARD ❑ PUBLICYYORKS form if any Hazardous Materiak are heing used as part of this proiect. LARGE ❑ FIRE DEPT Copy of Planning Approti al Letter or Nleeung YY ith Planning prior to 1LAJOR u SANITARY SM-ER DISTRICT Submittal of Building Permit application. ❑ ENV1ROAI11ENTAL 11EALT H . CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10878 SYCAMORE CT CONTRACTOR:DE SWANSON PERMIT NO: 13060135 CONSTRUCTION OWNER'S NAME: DAVE MEHUYS 2433 CORY AVE DATE ISSUED: 12/04/2013 OWNER'S PHONE: 4087331617 SAN JOSE,CA 95128 PHONE NO:(408)891-0742 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL � ADD BALCONY, CHANGE ROOF LINE, REMODEL 182 SQ License Class J Lic.k � '6 S , FT IN LIVING ROOM,INSTALL RECESSED LIGHT II T Contractor Df*r 5N/�/lSla!`z DateYU MASTER AREA 10 LIGHTS AND 4 SWITCHES,ADD FLOOR C� / HEATING I hereby affirm that I am licensed under the provisions of Chapter 9 REVISION#2-ON SECOND DECK LEVEL,CHANGE DOOR (commencing with Section 7000)of Division 3 of the Business&Professions SWING ON PROPOSED(N)DOOR& CONVERT(E)SECOND Code and that my license is in full force and effect. WINDOW TO(N)DOOR(SAME SIZE, NO STRUCTURAL)- I hereby affirm under penalty of perjury one of the following two declarations: ISSUED 6/10/14 I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25000 j.J>dve and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:34257036.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180D PE IT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 LED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses whic a rcrue against said City in consequence of the /b granting of this permit ovally,the applicant understands and will comply sued by: Date: — with all non-point so re a ulations per the Cupertino Municipal Code,Section 9.18. .�� /` _ RE-ROOFS: Signature Date // All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See,7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)show d I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equip nt or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by th72/55, 5533, Air Quality Management District performance of the work for which this permit is issued. will maintain compliance with the Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Section and 25534. Section 3700 of the Labor Code,for the performance of the work for which this q _zc permit is issued. Owner or authorized agent: Date t/' certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18, Signature Date CONSTRUCTION PERMIT APPLICATION 12 COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408) 777-3228• FAX (408)777-3333• buildingQcupertino.orq / ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI REVISION/DEFERRED ORIGINAL PERMIT# b U I �/ PROJECT ADDRESS # APN IU y�z 4,- C,` 2 -S _ OWNER NAME v PHONE _ �/ ` V 7 E-MAIL STREET ADDRESS CITY, STATE,ZIP FAX CONTACT NAME PHONE E-MAIL STREET ADDRESS CITY,STATE, ZIP FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME ♦✓1 W / LICENSE N 4$ER, �_ LICENSE TYPE BUS.LIC# COMPANY NAME i �Z v w �✓ ��/ E-MAIL FAX STREET ADDRESS 7 ��,[�A/�L r CITY,STATE,ZIP P ONE Z ARCHITECT/ENGINEER NAME " LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK _ oat L LsvL{e- r- Y,/ L EXISTING USE PROPOSED USE CONSTR.TYPE #STORIES USE TYPE OCC. SQ,FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: LJDETACH []ATTACH #DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES BEING ADDED? ❑NO ADDITION? ❑NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY: TOTAL V.ALUA PLANNING APPL# ❑No PLANNING APPROVAL LETTER EICHLER HOME? E]N By my signature below,I certify to each of the llowing: I am the property owner or aut ed agent to act on the pro rty own s behalf. I have ad this application and the information I have provi Kiorrect. I have read the Description o Workand verify it is accurat . Iagr c comply with all a plicable local ordinances and state laws relating to b I got ' authorize representatives of Cupertino to enter the above- Ified property for inspection purposes. Signature of Appl icant/Agent: Date: 10 SUPPLEMENTttFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS- ❑ PLANNING PLAN REVIEW _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. E]_MAJOR. El SANITARY SEWER DISTRICT - ❑ ENVIRONMENTAL HEALTH BIdg,4pp 2011.doe revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 10878 sycamore ct DATE: 06/10/2014 REVIEWED BY: melissa APN: 342 57 036 BP#: 13060135 `VALUATION: Iso 'PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY SFD or Duplex PENTAMATION 1GENRES USE: PERMIT TYPE: WORK REVISION # 2 - ON SECOND DECK LEVEL CHANGE DOOR SWING ON PROPOSED N DOOR & SCOPE CONVERT (E) SECOND WINDOW TO (N) DOOR (SAME SIZE, NO STRUCTURAL) -ISSUED 6/10/14 NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District, etc.). Thesefees are based on the prelimina information availahle and are only an estimate. Contact the De t or addn'1 info. FEE ITEMS (Fee Resolution 11-053 Ff' 7%1%73) FEE QTY/FEE MISC ITEMS Plan Check Fee: Hourly Only? ® Yes Q No $0.00 0 hours Plan Check, Hourly Suppl. PC Fee: Q Reg. Q OT 0.0 1 hrs $0.00 $139.00 ISTPLNCK PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT Fo,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Work Without Permit? 0 Yes E) No $0.00 G Advanced Planning, Fee. $0.00 Select a Non-Residential G Building or Structure i Strom Motion Fee: $0.00 Select an Administrative Item Bldg,Stds Commission Fee: $0.00 SUBTOTALS: $0.00 $139.00 TOTAL FEE: $139.00 Revised: 04/01/2014 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 C O P E RT I N O Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST 22 JOB ADDRESS: lof 7 e 1%1'911e- PERMIT -JS OWNER'S NAME: fll- PHONE# 4'49'K / - O 6 7 GENERAL CONTRACTOR: L-'. W��So,d BUSINESS LICENSE# ADDRESS: Z Y 7,7 dK�� S.t J-dflr CITY/ZIPCODE: 9 t-t 7 *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: j/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating U Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering �-- Plumbing Roofing Septic Tank Sheet Metal L T Sheet Rock (/ Tile 7' G" .v►I G c2v V r L yi✓G— /0 - 1.7 - 20ly caner/Contractor Signature Date Insulation Certificate V I Awnher and Street Count} u i n Lot N Description of Installation ROOF Material Brand Narne j Thickness(inches) Thermal Resistance(R-Value) CEILING Batt or Blanket Type FIBERGLASS Brand Name JOHNS MANY11 I r' Thickness(inches) Thermal Resistance(R-Value) 7'2(" Loose Fill Type FIBERCH ASS Brand Nanic JOHNS 1ANVII LF Contractor*-,minimum installed wei2hLift' 117. Minimum thickness inclic; Manufacturer's installed weight per square foot to achieve................Thermal Resistance(R-VaILIC) EXTERIOR WALL Material FIBERGLASS Brand Njme JOUNS MAN% Thickness(inches) Thermal Resisiance iR-Value) RAISED FLOOR Material -PTPPI?(-,T A(Z4 Brand Name __ lQHNS_MA- XVII L_F_ Thickness(inches) Thermal Resistance(R-Value) SLAB FLOOR Material . Brand Name Thickness(inches) Thermal Resistance (R-Value) Width(inches) FOUNDATION WALL .MaLerial Brand Nam--- Thicknzss i,inches) Thermal Resistance(R-Value) Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with rho current Building Energy Efficiency Standards for new residential buildings contained in Title H4 Of the Califomia Administrative Code. General Coniracmr(Buiidcn License Numlw Sipature and Title, Date Ponzini Insulation, Inc. 635993 Sub-Contractor(Insulation installer) License Number Sienature ar,d itle Date PFVISEG JULY 2005 SWANSON -- ---- -- ---- ----- CONSTRUCTION 2433 CORY AvENUE SAN JOSE, CA 95128 408.891 .0742 May 28, 2014 City of Cupertino Building Department 10300 Torre Ave. Cupertino, CA 95014 Building and Planning, We would like an extension of the Building Permit 413060135 issued on December 4, 2013 for 10878 Sycamore Ct. The original design for the custom fabricated deck railing became a bit financially prohibitive. Much time has been spent searching and researching for an economical alternative for the deck railing. A decision has been made to use the Feeney prefab railing system which is also pre-engineered. Work on the project has started May 27, 2014. We would appreciate a permit extension to support uninterrupted progress for this project. Thank you Drew Swanson CALIFORNIA CONTRACTORS LICENSE#886654 5/28/2014 PAGE 1 OF 1 BUILDING ENERGY ANALYSIS REPORT PROJECT: McHUYS RES ALTERATION TILE 24 10878 SYCAMORE COURT CUPERTINO, CA. Project Designer: MARIANNE or DAVE McHUYS 10878 SYCAMORE COURT CUPERTINO, CA. 95014 (408) 718-0679 Report Prepared by: ELMON (AL) BRADY AM CONSULTANTS 2292 CRESTLINE ROAD PLEASANTON, CA. 94566-5406 (925) 462-8108 Job Number: 13-167 Date: 6/4/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2006 Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number:2289 RunCode:2013-06-04707.43:45 ID:13-167 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 EnergyPro 5.1 by EnergySoft Job Number: ID:13-167 User Number:2289 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type ®Single Family ❑Addition Alone Date McHUYS RES ALTERATION TILE 24 ❑Multi Family m Existing+Addition/Alteration 6/4/2013 Project Address California Energy Climate Zone Total Cond.FloorArea Addition #of Stories 10878 SYCAMORE COURT CUPERTIN CA Climate Zone 04 486 0 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Rafter R-30 215 Altered Wall Wood Framed R-13 26 Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear(E) 12.0 0.550 0.67 none none Bug Screen Removed Rear(E) 20.0 0.390 0.37 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 60%AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status EXISTING SYSTEM Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by Ener Soft User Number.2289 RunCode:2013-06-04T07.43:45 ID:13-167 Pa e 3 of 10 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R Project Name ®Single Family ❑Addition Alone Date Building Type McHUYS RES ALTERATION TILE 24 ❑Multi Family ® Existing+Addition/Alteration 6/4/2013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System EXISTING SYSTEM does not include a cooling system,field verification is not necessary. I"ftw HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. EnergyPro 5.1 Ey Enem ySoft User Number.2289 RunCode:2013-06-04T07:43:45 ID:13-167 Page 4 of 10 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date McHUYS RES ALTERATION TILE 24 ❑Multi Family m Existing+Addition/Alteration 6/4/2013 r ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 0.29 0.27 0.02 Space Cooling 12.96 12.29 0.68 Fans 5.60 5.43 0.17 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 18.85 17.98 0.87 Percent Better'rhan Standard: 4.6% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (SK9 213 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (SK9 0 0 Fuel Available at Site: Natural Gas (N149 0 0 Raised Floor Area: o (NE) 46 20 Slab on Grade Area: o (SE) 0 0 Average Ceiling Height: 9.0 Roof 215 0 Fenestration Average U-Factor: 0.39 TOTAL: 20 Average SHGC: 0.37 Fenestration/CFA Ratio: 4.1% REMARKS �1rr STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company AM CONSULTANTS Address 2292 CRESTLINE ROAD Name ELMON(AL)BRADY 4/7013 City/State/ZipCity/State/Zip PLEASANTON, CA.94566-5406 Phone (925)462-8108 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company MARIANNE or DAVE McHUYS Address 10878 SYCAMORE COURT Name MARIANNE or DAVE McHUYS City/State/Zip CUPERTINO, CA. 95014 Phone (408) 718-0679 Signed License# Date EnergyPro 5.1 by EnerqySoft User Number-2289 RunCode:2013-06-04707.43.45 ID:13-167 Page 5 of 10 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date McHUYS RES ALTERATION TILE 24 ❑Multi Family m Existing+Addition/Alteration 6/4/2013 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 215 0.035 R-30 0 0 Altered 4.2.2-A17(E=4.2.1-A2 EXISTING ZONE Wall 26 0.102 R-13 78 90 Existing 4.3.1 A3 EXISTING ZONE FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 12.0 0.550 Default 0.67 Default 78 Removed Double Non Metal Clear EXISTING ZONE 2 Window 20.0 0.390 NFRC 0.37 NFRC 78 New FRENCH DOOR EXISTING ZONE y1l�►' (1) 1-1-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC Hat 7 Wd Len Hat LExt I REA Dist Len Hat Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 Ene Pro 5.1 by EnergySoft User Number.2289 RunCode:2013-06-04T07:43:45 ID:13-167 Page 6 of 10 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date McHUYS RES ALTERATION TILE 24 ❑ Multi Family m Existing+Addition/Alteration 6/4/2013 err BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existing Altered Removed Volume Year Built EXISTING SYSTEM FAMILYROOM 486 4,374 2000 Totals 1 0 01 486 0 HVAC SYSTEMS System Name Qty. I Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status EXISTING SYSTEM 1 Central Furnace 80%AFUE No Cooling 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Ducts S stem Name Heating Cooling Duct Location R-Value Tested? Status EXISTING SYSTEM Ducted Ducted Attic, Ceiling Ins, vented 8.0 ❑ New WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. Type Distribution (Btu h) al or RE Pilot Value Status MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length ft 0 0 m 0 U3 Pipe Pipe Insul. Control Qty. HP Plenum Outside Buried Q — System Name Length Diameter Thick. EnergyPro 5.1 by EnergySoft User Number.2289 RunCode:2013-06-04707.43:45 ID:13-167 Pae 7 of 10 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date McHUYS RES ALTERATION TILE 24 6/4/2013 NOTE:Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R,CF-1 R-ADD,or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*) below.This Mandatory Measures Summary shall be incorporated into the permit documents,and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary.Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: §116(a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC,and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a):Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(1):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(1)when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b):Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 50 c :Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-13 insulation in raised wood-frame floor orequivalent LI-factor. 150(f):Air retarding wrap is tested,labeled,and installed according to ASTM El677-95 2000 when specified on the CF-1 R Form. 150 :Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A:Masonry or factory-built fire laces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equip ed with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are Rrohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113:HVAC equipment,water heaters,showerheads,faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve,backflow prevention, pump isolation valve,and recirculation loop connection requirements of§113(c)5. §115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. 150(h):Heating and/or cooling loads are calculated in accordance with ASHRAE,SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150U)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150@113:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §1500)2:First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-13. §1500)2:Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2:Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table 123-A. §150(i)3A:Insulation is protected from damage,including that due to sunlight,moisture,equipment maintenance,and wind. §1500)3A:Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(i)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number.,2289 RunCode:2013-06-04T07:43:45 ID:13-167 Page 8 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date McHUYS RES ALTERATION TILE 24 6/412013 §150(m)l:All air-distribution system ducts and plenums installed,are sealed and insulated to meet the requirements of CMC Sections 601, 602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A,or UL 181 B or aerosol sealant that meets the requirements of UL 723.If mastic or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150(m)l:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible,manually operated dampers. §150(m)9:Insulation shall be protected from damage,including that due to sunlight, moisture,equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10:Flexible ducts cannot have porous inner cores. §150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light. §114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing,flow rate, piping,filters,and valve requirements of 150 Residential Lighting Measures: §150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2. 150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d),and shall not contain a medium screw-base socket. 150(k)6:Lighting integral to exhaust fans,in rooms other than kitchens,shall meet the applicable requirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION:Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer,energy management system (EMCS),or a multi-scene programmable control system;and all permanently installed luminaries in garages,laundry rooms,closets greater than 70 square feet,and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number.,2289 RunCode:2013-06-04T07:43:45 ID:13-167 Page 9 of 10 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date McHUYS RES ALTERATION TILE 24 6/4/2013 §150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages,laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages,laundry rooms, closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2:Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)12:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13:Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch,a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system (EMCS)not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptions to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3:Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket,and consume no more than five watts of power as determined according to§130(d). §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134,and 146. §150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number.2289 RunCode:2013-06-04T07.43.45 ID:13-167 Page 10 of 10