Loading...
14050077 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10146 ALPINE DR CONTRACTOI re" ern PERMIT NO: 14050077 conSGyU G/7.0 OWNER'S NAME: AVRAM MEYERS AND GALE MEYERS DATE ISSUED:05/13/2014 OWNER'S PHONE: 4155156644 PHONE NO: LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL / INSTALL 4 PV SYETEMS W/7 PANELS&2.5KW EACH(28 License Class Lie.u g �`7 PANELS/10KW TOTAL).INSTALL 4(N) 100 AMP SUB p�j PANELS IN REAR YARD AREA Contractor ���ACj�iV " �tij{jQ�✓IJat� I hereby affirm that I am licensed under the provisions of 4aplJ9 (commencing with Section 7000)of Division 3 of the Business&Professions t Code and that my license is in full force and effect. t I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's t Compensation,as provided for by Section 3700 of the Labor Code,for the pert mance of the work for which this permit is issued. Sq. Ft Floor Area: Valuation:$50000 ave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32615105.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS T ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 1 LED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the > r 3 granting of this permit. Additionally,the applicant understands and will complyr sue //V with all non-poin7sour egulat e Cupertino Municipal Code,t�etl'un 9.18. 1 ?? f RE-ROOFS: Signature Date J All roof;shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Section a 25534. Section 3700 of the Labor Code,for the performance of the work for which this j permit is issued. Owner or authorized agent: Date: I certify,that in the performance of the work for which this permit is issued,1 shall riot employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18, Signature Date ALTERNATIVE ENERGY PERMIT APPLICATIO 0� COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISIONA' E 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 �O CUPERTINO (408)777-3228• FAX(408)777-3333•building(okupertino.org PROJECT ADDRESS O ) APN# (J^7 l S j o\— OWNER NAME V i / r PHONE J f0 E-MAR STREET ADDRESS CITY, STATE,ZIP FAX CONTACT NAME ^ - / PHONE n 7 E-MAIL O ` .4 STREET ADDRESS Z�O 3 � A -- CITY,STATE, ZIP C0� r O FAX ❑ OWNER ❑ ONT'ER-BUILDER ❑ OWNER AGEN'T YJ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGWEER ❑ DEVELOPER ❑ TENANT TRACTORN LICENSE NUMBER Q j��J LICENSE TYPE BUS.LIC# CO. NYj A^ Q N S EMAIL Q (- o � FAX ✓' D STREET ADDRESn � CITY,S TE,ZIP e S — PHO, HO ��94- J F ARCHITECT/ENGINEER NAME �G LICENSE NUMBER 't BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE. USE OF ❑ SFD or DuplexD-44tr i amily PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ElYes L1No FLOOD ZONE ❑ Yes ❑ NO uRUSOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FORSOLARPANELS: NUMBER OF PANELS/UNITS: Z KILOWATTS(COMMERCIAL ONLY): 16)c. I ] TOTAL VALU ION: 1�w DESCRIPTION OF WORK , ,4,41 / 00�ft By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the pg6FT17 owner's behal ave Is application and the information I have provided is correct. I have rea a Description of Work and verify it is accurate. la to y applicable local ordinances and state laws relating to build' struction. I aur e epresentatives of Cupertino to enter the above-' flee fo inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY w ❑ OVER-THE-COUNTER F ❑ EXPRESS U U w ❑ STANDARD U a ❑ LARGE a MAJOR' PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10146 ALPINE DR DATE: 05/13/2014 REVIEWED BY: MELISSA APN: 326 15 105 BP#: A / 'VALUATION: $50,000 "PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY Multi-Family Dwelling Buildina is PENTAMATION SOLAR-RES USE: 3 Stories Yes ® No PERMIT TYPE: WORK Lioso TALL 4 PV SYETEMS W/7 PANELS & 2.5kW EACH 28 PANELS/10kW TOTAL). INSTALL 4 N SCOPE AMP SUB PANELS IN REAR YARD AREA Elec.Plan Check 0.0 1 hrs $0.00 Elec. Permit Fee: IEPERMIT Other Elec. Insp. 0.0 hrs $47.00 Ilk h NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District, etc.). Thesefees are based on the prelimina information available and are only an estimate Contact the Dept for addn 7 info. FEE ITEMS (Fee Resolution 11-053 E{f. 711%13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 10 kW Alternative Energy System Suppl. PC Fee: Q Reg. Q OT0.0 hrs $0.00 $575.00 IPHOTOVREs I Photovoltaic System PME Plan Check: $0.00 100 amps Electrical Permit Fee: Hourly Only? C)Yes Q No $0.00 $47.00 1 IBELEC200 Services Suppl. Insp. Feer Reg. Q OT 0.0 hrs $0.00 100 amps Electrical PME Unit Fee: $0.00 $47.00 IBELEC200 Services PME Permit Fee: $47.00 100 amps Electrical Constrilclion 141x, FT $47.00 IBELEC200 Services Administrative Fee: IADMIN $44.00 100 1 amps Electrical Work Without Permit? 0 Yes Q No $0.00 $47.00 IBELEC200 I Services Advanced Planning Fee: $0.00 Select a Non-Residential Travel Documentation Fee: ITRA VDOC $47.00 Building or Structure Strong Motion Fee: IBSEISMICR $5.00 = hrs Inspections Bldg Stds Commission Fee: IBCBSC $2.00 $139.00 ISTINSP Inspection, Hourly SUBTOTALS: $145.00 $902.00 TOTAL FEE: 1 $1,047.00 Revised: 04/01/2014 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RT I N O Fax: 408-777-3333 CONTRACTOR / SUBCONTRACTOR LIST JOB ADDRESS: to Ll 6 A[ PERMIT# N-10- OWNER'S DOWNER'S NAME: 4V ( W&99 PHONE# GENERAL CONTRACTOR: r � errvlce BUSINESS LICENSE# ADDRESS: y0Z 3 CITY/ZIPCODE: Ed 4 *Our municipal code requires all businesses working in the city to have a City of Cupertino busi ess li ense. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature D e Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/ Carpeting Linoleum/Wood Glass/ Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/Contractor Signature D e ()o-7 F:on L SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 (408)777-3228• FAX(408)777-3333 • building(,cupertino.ora Permit No. /`10--ro-6-7 Address �t/( � D 3ti"L 1"`� #of Alarms Smoke: Carbon Monoxide: PERMIT CANNOT BE FINALED AND COMPLETED UNTI.L THIS CERTIFICATE HAS BEEN SIGNED AND RETURNED TO THE BUILDING DIVISION PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the'following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s) On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. 1 have read and agree to comply with the terms and conditions of this statement Owner(or Owner Agent's)Name: Signature..................................................................................................................Date: ................... Contractor Name: }} (�Lt � , I , Si nature...✓...... CJI ? / Lic.#......�!... ........./..'1... ....Date: Smoke and COform.doc revised 03/18/14 Quick Hook®- Flat Tile Mount f QMFTk,.,,,, ITEM NO. DESCRIPTIONQTY. gr 1 BASE PLATE,QUICK HOOK USA,4-1/2"WIDE-6063- 1 2 AI to 9O�q ILL 2 LAG SCREW,HEX HEAD, 5/16"x 3-1/7', 18-8SS 2 1 4 3 QUICK HOOK USA,VERTICAL,606146,MILL 1 4 SET SCREW,HEX SOCKET, 10-32X5/8", 18-8 SS I SUBRASH ING,QUICK HOOK USA V2-4.5"BASE,9"X 5 12"X.032"-3003-MILL 1 3/32"HEX DRIVE ON SET SCREW 1.50 O T5 3 O O SLIDE DESIRED LOCATION CUPERTINO 0 o Buildinq Department 29 75 H SIDES OF SLOT SERRATED 14AY 13 2014 VIEWED FOR CODE COMPLIANCE 6.57 —L ✓ RT�i/ 01.39 6.27' - Reviewed By I Glick Mount `s 1 1.89 2.21 TITLE: QMFTH: QUICK HOOK USA-FLAT �} TILE MOUNT 4.56-- f—I.1 UNLESS OTHERWISE SMOKED: $IZE DRAWN BY: RAD REV 9.06 9 l)WFNS1OIIS ANI W I.CHES FRA1GIERANG-S: TWOC ONALS I/B A DATE: 2/s/2013 4 IfpMOO�ipNCp+ 116 auH11GRrvE iaEreoPFxir or oUC[rblM rv.ru:r aBYaolCnonNrMl Ox.vt DO NOT SCALE ORAWWG Iwo'LACE OEGIMAI .18 WNpE WMdlI T1EMt711B,P8te.690NOi pXS woUrrtwaPRaeIIED. 1NRff%,1Cf;DECIMAL 1,115 SCAJE.18 WEIGHr:1.62 SHEET I OF 5 4 3 2 Quick k USA Failure Test Result.s • Average Ultimate Load Capacities(lbf)in Douglas Fir Configuration source Document Puffout Compression Shear Para6el to Shear Perpendicular Rafter to Rafter Centered:All base plate sizes with hook positioned AME Report#11 2640C'Quick Hook USA-Flat Tile 876 685 1058 5a3 directly over the lag screws(see Appendix A&B of Mount*With 1.5 Base Plate referenced report for test setup) This report shows results for Quick Hook USA,both Flat and Curved Tile models,when the hook is posi- tioned directly over the leg screws Offset 4.5'Base Plate:4.5"wide base plate with AME Report#112640C"Quick Hook USA-Curved-rite 1084 712 1219 532 hook positioned at opposite and of base plate from lag Mount with 4.5"Base Plate screws(see Appendix A 8 B of referenced report for test setup) This report shows results for our Quick Hook USA- Flat Tile Mount Offset 6^Base Plate:6'wide base plate with hook AME Report#112640C"Quick Hook USA-Curved Tile 1246 692 1341 584 positioned at opposite end of base plate from lag Mount with 6"Base Plate screws (see Appendix A&B of referenced report for lest setup) This report shows results for our Quick Hook USA- Curved Tile Mount Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2)See IBC for required edge distances. IMPORTANT:To maintain waterproofing of substrate it is important to make sure the aluminum sub-flashing is properly placed over the base plate and under the course of paper above. If the paper above does not reach,due to layout,place an additional piece of roofing paper over the sub-flashing and under the next course of paper above.(See instructions on reverse) q • uickMount PV1 BI7.2.3-15 RESPECT THE ROOF Apr-2014,Rev 8 Quick Hook® Flat Tile Mounting Instructions - Rafter Installation The Quick Hook is designed for flat and S-shaped curved tiles.Requires roofing battens. Installation Tools Required:stud finder,tape measure,utility knife,3/32"hex key,drill with 7/32"bit,impact dril with 1/2"socket,caulking gun,one tube of sealant compatible with roofing materials,roofing bar,hand broom,stapler,18"wide piece of underlayment or materials for 3-course method during deck flashing installation. WARNING:Quick Mount PV products are NOT designed and should NOT be used for anchoring fall protection equiprnen�* � ,rq t Remove the tile at selected location of the mount. Rest the base plate over center of rafter and mark Drive lag screws into rafter through the two holes Locate and mark the center of the rafter. center of holes, Drill two 7/32"pilot holes and fill to a solid,snug fit.DO NOT over tighten lag screws, with sealant compatible with roofing material. this may compromise their holding strength. r^' Slide hook into position on base plate.The hook Carefully clean the undedayment,then apply bead of Proceed with weatherproofing using three-course must not overhang the side edges of the base compatible sealant in the shape of an upside down U method or lapped paper method.*When using pa- plate.Tighten set screw with hex key. on the backside of the sub-flashing and install flashing per method,cut a piece of underlayment 18"wide over mount Fasten sub-flashing to deck with one roof- to slide under the course above and over the cub- ing nail in each top corner.Do not nail bottom comers. flashing.If course above is too high,you must use ad- ditional underlayment to ensure proper overlapping. notch You •w ready forof • choice. • •w all the directions of modulethe rack manufacturer as well as the �4 All roofing manufacturers' written Instructions • be • • by •ne modifying a roof Please consult •• 5pecs and instructionsprior to roof.touching the Replace the tile above the hook.If necessary,notch Bolt the side-mounted rail of your choice to the For more details on underlayment waterproofing please the bottom of the tile to make space for the raised hook,using the rail manufacturer's hardware. visit,http:/A"wguirkmountpvcom/tile-waterproofing hook. BI 7.2.3-15 Apr-2014,Rev 8 V Quick Hook® W Flat Tile Mount I QMFTH Additional Dimensions RAFTER - 2.25 THIS EDGE TOWARDS ROOF RIDGE � - ° ° ° ° ° ° ° ° 158.00" 9.00 4.92 L 4.50"ADJUSTABLE LOCATION -1 f -2.25 THIS EDGE TOWARDS ROOF RIDGE 7 1 12.00 .23 1.85 SUBFLASHING (ITEM 5) 4.50 .75-11.50 1.50 .99 I 4.50 2.00 J 0 0 1. C.Ya.,ck Mount PV TITLE: QMFTH: QUICK HOOK USA-FLAT 6X 0.33CLEARANCE TILE MOUNT FOR 5/16'HARDWARE UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DDIMENSIONS ARE IN INCHES v BASE PLATE(ITEM 1) TOLERANCES: FRACTIONAL I(8 A DATE: 2/5/2013 4 N PR°POlTARY AND C°Nro1NML TWO PLACE DECIMAL 1.18 -- THEINFORMA 000NI .'THIS DRAWING G T�SOL?PROPERTY OF QUICK MOUNT PV.ANY RMODUCTION IN PARI OR AS DO NOT SCALE DRAWING A WHOLE WITHOUT THE WR1REN PERMISSION OF QUICK MOUuT PV IS PROHWED. THREE PLACE DECIMAL :.125 SCALE:1:8 WEIGHT:1.62 SHEET 2OF2 A 5 4 3 2 1 rfl Quick Mount 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com 2700 Mitchell Dr.,Bldg.2 • Walnut Creek,CA 94598 BI 7.2.3-15 Apr-2014,Rev 8 ©2014 by Quick Mount PV.All rights reserved. F-SERIES SOLAR PANELS HIGH PERFORMANCE & EXCELLENT DURABILITY SERIES • 20.4%efficiency Ideal for roofs where space is at a premium or where future expansion might be needed. • High performance Delivers excellent performance in real world conditions, such as high temperatures, HIGH EFFICIENCY° clouds and low light.'23 Generate more energy per square meter • Proven value E-Series residential panels convert more sunlight to electricity Designed for residential rooftops, ESeries panels deliver the features, value and producing 36%more power per panel,' and 60% more energy per square meter over 25 years.3 performance for any home. HIGH ENERGY PRODUCTION Produce more energy per rated watt High year one performa 79% more Waft.3 This advantage i r time, prodr�c'ggi; energy over the first 25 rs t your needs. �r rCmerlt r MAY 13 2014 Maxeon-Solar Cells:fundamentAkr6tter. REVIEWED FOR CODE COMF'LiANCE Engineered for performonce,designed for durability. Revieww 0 11100'%J 0% a Engineered for peace of mind More Energy Designed to deliver consistent, trouble-free a i 10% Per Rated Watt energy over a very long lifetime.4.5100% 00% V 90% 35%more, Designed for durability a- year 25 The SunPower Maxeon Solar Cell is the Q, 80% only cell built on a solid copper foundation. w 70% Conventional Virtually impervious to the corrosion and 60% cracking that degrade ConventionalIn so°i° Panels.4,1 `~ O 5 10 15 20 25 Years #1 Ranked in Fraunhofer durability test.10 0 10°! EQor 100%power maintained in Atlas 25* Maintains High oy Q F comprehensive PVDI Durability test.11 4) a% Power at High Temps p ]No Light-Induced ` - i Degradation a 6: 0 vHor6r+ . `c °, � 12 FIELD�" Q _ I High Average Watts m 4% Better Low-Light and Spectral Response LU 2% High-Performance Anti-Reflective Glass 0% sunpowercorp.com SUNPOWER E-SERIES' SOLAR PANELS SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY 100% 95 90° 85% 80% 75% 0 5 10 15 20 25 0 5 10 IS 20 25 Ys Years More guaranteed power:95%for first 5 years, Combined Power and Product defect 25 year coverage -0.4%/yr.to year 25.8 that includes panel replacement costs.° ELECTRICAL DATA OPERATING CONDITION AND MECHANICAL DATA E20-327 E19-320 Temperature —40°C to+85°C Nominal Power12(Pnom) 327 W 320 W Wind: 2400 Pa, 245 kg/m2 front&back Power Tolerance +5/-0% +5/-0% Max load Snow: 5400 Pa, 550 kg/m2 front Avg. Panel Efficiency13 20.4% 19.8% Impact resistance 25mm diameter hail at 23 m/s Rated Voltage(Vmpp) 54.7 V 54.7 V Appearance Class A Rated Current(Impp) 5.98 A 5.86 A Solar Cells 96 Monocrystalline Maxeon Gen II Open-Circuit Voltage(Voc) 64.9 V 64.8 V Tempered Glass High transmission tempered Anti-Reflective Short-Circuit Current(Isc) 6.46 A 6.24 A Junction Box IP-65 Rated Max. System Voltage 1000 V IEC&600 V UL Connectors MCA Maximum Series Fuse 20A Frame Class 1 black anodized (highest AAMA rating Power Temp Coef. —0.38%/°C Weight 18,6 kg Voltage Temp Coef. —176.6 mV/°C Current Temp Coef. 3.5 mA/°C TESTS AND CERTIFICATIONS Standard tests IEC 61215, IEC 61730, UL1703 REFERENCES: 1 All comparisons are SPR-E20-327 vs.a representative conventional Quality tests ISO 9001:2008, ISO 14001:2004 panel:240W,approx. 1.6 m2, 15%efficiency. EHS Compliance RoHS,OHSAS 18001:2007, lead Free, 2 PVEvolution Labs"SunPower Shading Study,"Feb 2013. PV Cycle 3 Typically 7-99/o more energy per watt,BEW/DNV Engineering"SunPower Ammonia test IEC 62716 Yield Report,"Jan 2013. 4 SunPower 0.251/o/yr degradation vs. 1.0%/yr conv.panel.Campeau,Z. Salt Spray test IEC 61701 (passed maximum severity) et al."SunPower Module Degradation Rate,"SunPower white paper,Feb PID test Potential-Induced Degradation Free: 1000V10 2013;Jordan,Dirk"SunPower Test Report,"NREL,Oct 2012. Available listings TUV,MCS, UL,JET,KEMCO,CSA,CEC, FSEC 5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful life is 99 out of 100 panels operating at more than 70%of rated power. 6 Out of all 2600 panels listed in Photon International,Feb 2012. 7 8%more energy than the average of the top 10 panel companies tested in 2012(151 panels, 102 companies),Photon International,March 2013. 8 Compared with the top 75 manufacturers.SunPower Warranty Review, 1046 mm Feb 2013. 9 Some exclusions apply.See warranty for details. 10 5 of top 8 panel manufacturers were tested by Fraunhofer ISE,"PV Module Durability Initiative Public Report,"Feb 2013. 11 Compared with the non-stress-tested control panel.Atlas 25+ Durability test report,Feb 2013. 12 Standard Test Conditions(1000 W/mz irradionce,AM 1.5,25°C). 13 Based on average of measured power values during production See http://www.sunpowercorp.com/facts for more reference information. Far more details,see extended dotasheet:www.sunpowercorp.com/datasheets.Read safety and installation instructions before using this product. ®May 2013 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY.FOR LIFE.,and SIGNATURE are trademarks or registered trademarks of SunPower Corporation.Specifications included in this datosheet are wbied to change without notice. sunpowercorp.com Doa,mem#505813 Rer A/A4_UK_AUS k. fi A' • z- SU11INY BOY .3000R-LIS r/ 2,807R 1,110 E` 400OTL-US / 5004TL-US / 6000 r► CUPERTINO 'rHE WORLD'S ONLY SECURE POWER SUPPLY , G e In Certified Innovative Powerful Flexible • UL 1741 and 16998 compliant •Secure Power Supply provides •97.2%maximum efficiency •Two MPP trackers provide • Integrated AFCI meets the require- daytime power during grid outages •Wide input voltage range numerous design options ments of NEC 2011 690.11 •Shade management with OptiTrac •Extended operating Global Peak MPP tracking temperature range SUNNY BOY 300011-US / 380011-US / 4000TL-US / 5000TL-US / 6000TL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US represents the next step in performance for UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracT'" Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power Supply feature provides daytime power in the event of a grid outage.High performance,flexible design and innovative features make the Sunny Boy TL-US series the first choice among solar professionals. ENGINEERED IN GERMANY ASSEMBLED99 IN THE USA= THE NEW SUNNY BOY TL-US RESIDENTIAL SERIES -..: HAS YET ALAN REDEFINED THE CATEC A NEW GENERATION OF INNOVATION Transformerless design produced in all types of climates and for Leading monitoring longer periods of time than with most and control solutions The Sunny Boy 3000TL-US / 380OTL-US traditional string inverters. / 4000TL-US / 5000TL-US / 6000TL-US rhe new-fL-US residential line features more are transformerless inverters, which means Secure Power Supply than high performance and a large graphic owners and installers benefit from high display. The monitoring and control options efficiency and lower weight. A wide input One of many unique features of the TL-US provide users with an outstanding degree of voltage range also means the inverters will residential series is its innovative Secure flexibility. Multiple communication options produce high amounts of power under a Power Supply. With most grid-tied inverters, allow for a highly controllable inverter number of conditions. when the grid goes down, so does the solar- and one that can be monitored on Sunny powered home. SMA's solution provides Portal from anywhere on the planet via an Additionally, transformerless inverters have daytime energy to a dedicated power outlet Internet connection.Whether communicating been shown to be among the safest string during prolonged grid outages, providing through R5485,or SMA's new plug-and-play inverters on the market. An industry first, the homeowners with access to power as long WebConnect, installers can find an optimal TL-US series has been tested to UL 1741 and as the sun shines. solution to their monitoring needs. UL 1699B and is in compliance with the arc fault requirements of NEC 2011. Simple installation Increased energy production As a transformerless inverter, the TL-US residential series is lighter in weight than OptiTrac'm Global Peak, SMA's shade- its transformer-based counterparts, making tolerant MPP tracking algorithm, quickly it easier to lift and transport. A new wall adjusts to changes in solar irradiation,which mounting plate features anti-theft security mitigates the effects of shade and results in and makes hanging the inverter quick and higher total power output.And,with two MPP easy.A simplified DC wiring concept allows trackers, the TL-US series can ably handle the DC disconnect to be used as a wire complex roofs with multiple orientations or raceway,saving labor and materials. string lengths. The 380OTL-US model allows installers to An extended operating temperature range maximize system size and energy production of -40 °F to +140 °F ensures power is for customers with 100 A service panels. Technical data Sunny Boy 3000TL-US Sunny Boy 380OTL-US 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max.usable DC power(@ cos tp s 1) 3200 W 4200 W Max.DC voltage 600 V 600 V Rated MPPT voltage range 175-480 V 175-480 V Mom efficient MPPT operating voltage ronge 125 V-500 V 125 V-500 V Min.DC voltage/start voltage 125V/150V 125 V/150 V Max.input current/per MPP tracker 18 A/15 A 24A/15A Number of MPP trackers/strings per MPP tracker 2/2 " a j Output(AC) ®® +I AC nominal power 3000 W 3330 W 3840 W ®� Max.AC apparent power 3000 VA 3330 VA 3840 VA •� �� Nominal AC voltage/adjustable 208 V/• 240 V/t 208 V/• 240 V/• AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V Shade management AC grid frequency;range 60 Hz/59.3-60.5 Hz 60 Hz/59.3-60.5 Hz Max.output current 15 A 16A Power factor(cos rp) 1 1 ;1 Output phases/line connections 1/2 1/2 Harmonics <4% <4% j Efficiency f Max.efficiency 96.8% 97.1'1 96.8% 97.2% CEC efficiency 96% 96.5% 96% 96.5% Protection devices Easier DC disconnection device 0 DC reverse-polarity protection 0 Ground fault monitoring/Grid monitoring 0/0 AC short circuit protection 0 All-pole sensitive residual current monitoring unit • Arc fault circuit interrupter(AFCI)compliant to UL 16998 0 Protection class/overvolloge category I/N General data Dimensions(W/H/D)in mm(in) 490/519/185 (19.3/20.5/73) DC Disconnect dimensions(W/H/D)in mm(in) 18712971190 (7.d/11.717.5) Brood temperature range Packing dimensions(W/H/D)in mm(in) 617/597/266 (24.3/23.5/10.5) DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280 (14.6/9.4/11.0) Weight/DC Disconnect weight 24 kg (53 Ib)/3.5 kg (8 Ib) Packing weight/DC Disconnect packing weight 27 kg (60 Ib)/3.5 kg 18 lb) Operating temperature range -40'C...+60°C (-40°F...+140°F) El Noise emission(typical) 5 25 dB(A) <25 dB(AJ Internal consumption at night <1 W <1 W Topology Transformedess Transformedess Cooling concept Convection Convection Secure Power Supply Electronics protection rating NEMA 3R NEMA 3R Features Secure Power Supply 0 0 Display:graphic 0 0 Interfaces:RS485/Speedwire/Webconnect 0/0 0/0 Warranty:10/15/20 years 0/0/0 0/0/0 Certificates and permits(more available an request) Ui1741,UL1998,UL169%,1EEE1547,FCCVM151tl-A&%,GW/CSAC22.2107.1-1 13 NOTE:US inverters ship with gray lids Flexible communications Type designation SB 3000TL-US-22 SB 3800TL-US-22 Techniml data continued on back -------- Accessories Efficiency cum SUNNY BOY 5000TL-US:'---------- --- ------ --- --- ----------------------- 98 Spcedwirc/VJelxonnetl RS485 --------------- R5485 inMrfoce inlerfcce DM-48SCB-JS40 96 ...................................... ............. SWDM-JSA 0 ............. 94 D& ,SnW-,e DZI 92 Fon kit zn FANKIT02-1 0 Et.(V,-175 V) V) I-------- (((V J4 88 Ea(V,-400 V) T -480 175 86 Et.(V,-480 V) v-M 0.0 02 0.4 0.6 U 10 0 Standard feature 0 Optional feature Not available Output power/Rated power ---------------- ------------------------------------------------------------------ Data at nominal conditions Technical data Sunny Boy 4000TL-US Sunny Boy 5000TL-US Sunny Boy 6000TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max.usable DC power(@ cos q)-1) 4200 W 5300 W 6300 W Max.DC voltage 600 V 600 V 600 V Rated MPPT voltage range 175-480 V 175-480 V 210-480 V MPPT operafing voltage range 125 V-500 V 125 V-500 V 125 V-500 V Min.DC voltage/start voltage 125 V/150 V 125 V/150 V 125 V/150 V Max.input current/per MPP tracker 24 A/15 A 30A/15A 30.A/15 A Number of MPP trackers/strings per MPP tracker 2/2 Output}AC) AC nominal power AOOO W 4550 W 5000 W 5200 W 6000 W Max.AC apparent power 4000 VA 4550 VA 5000 VA 5200 VA 6000 VA Nominal AC voltage/adjustable 208 V/e 240 V 0 208 V/0 240 V/0 208 V/0 240 V/0 AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V 8- Im AC grid frequency;range 60 Hz 59.3-60.5 Hz 60 Hz 59-3-60.5 Hz 60 Hz 59.3-60.5 Hz Max.output current 20A 22A 25 A Power factor(cos p) Output phases line connections 1/2 1/2 1/2 Harmonics <4% <A% <A% Efficiency Max.efficiency 96.8% 97.2% 96.8% 97.1% 96.8%* 97,1%* GEC efficiency 96% 96.5% 96% 96.5% 96%* 96.5%* Protection devices DC disconnection device 40 DC reverse-polarity protection 4111 Ground fault monitoring/Grid monitoring 0 AC short circuit protection All-pole sensitive residual current monitoring unit • 62 Arc fault circuit interrupter(AFC))compliant to UL 16998 • Protection class overvoltage category I IV General data Dimensions(W H/D)in mm(in) 490 519 185 (19.3 20.5 7.3) DC Disconnect dimensions(W/H/D)in mm(in) 187 297 190 (7.4/11.7/7.5) p Packing dimensions(W/H/D)in mm(in) 617 597 J 266 (24.3/23.5/10.5) DC Disconnect packing dimensions(W/H/D)in mm(in) 370 240 280 (14.6/9.4/11.0) Weight/DC Disconnect weight 24 kg (53 1b) 3-5 kg (8 lb) Packing weight/DC Disconnect packing weight 27 kg (60 lb) 3.5 kg (8 lb) Operating temperature range -AO*C...+60'C (-AO*F...+IAO*F) Noise emission(typical) <25 dB(A) <29 dB(A) <29 dB(A) Internal consumption at night <I W <1 W <I W Topology Transformerless Transformerless Transformerless Cooling concept Convection Convection Active Cooling Electronics protection rating NEMA 3R NEMA 3R NEMA 3R Features Secure Power Supply 41 0 41 Display:graphic 0 0 0 Interfaces:RS485/Speedwire/Webconnect 0/0 0/0 0/0 Warranty:10/15/20 years 6/0/0 */0/0 */0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 16998,IEEE 1547,FCC Part 15(Class A&8),CAN/CSA C22.2 107.1-1 Preliminary data as of February 2014.NOTE:US inverters ship with gray lids 0 Type designation SB 4000TL-US-22 SB 5000TL-US-22 SB 6000TL-US-22 Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC MODULES ® sunpower327 © 28 QTY ❑ ROOF CONDITION PITCH OF ROOF ROOF AZIMUTH Client Meyers INVERTER ❑ SUNNYBOY ❑ SOLECTRIA ❑ FRONIUS COMP 22 Address: 10146 Alpine DR ❑ ❑ ® TILE GOOD City: Cupertino UNIRAC ❑ xxxv ❑ LOW TILT ❑ METAL Phone: CLYCKSYS F-1 ❑ ❑ NON COMP 1 �/ 30B #: 1-4054 PRO-SOLAR❑ ❑ HIGH TILT ❑ torch down ❑ 'yqY�► � TOTAL PANELS- 28I k PANEL SCO ec • 4 x sunnyboy 3000us-12 4 x new 100A sub panel NJ`+ 200A or D 3 Z77 main meter cabinet 125A SUB aplpipr /� PANEL � ` � quick hook 'le footing Jn CUP Tjf O S O �'OJul Building DA arkment MAY 13 2014 REVIEWED FOR GCa�>E leviewed B MODULES RUN IN (� ' SERIES )C0= cOMML, ARALLEL N O 1 STORY XI b/ssetofa/ NCO�s/oN �? 2 STORY � _ std O �FRT'9�•i 3 STORY a / r®fro 9es or�o�st�saeci f• I/ �`NO 447' �e St �, w;tho a�tepdt°t/on°ahon FNG LTA- 'T. ROOFPENETR.4TIONSATN o of Sapp/ins%/tjs4 US'T 48-OIC WITH31/2"S.§�AG� /Serer o�aQ/7 �� o,�en r o/e�eatat Hardware visible X Yes WITH#IOGROUNOL ons tObeaasaec/ e r, Hardware n n9 No �. '.� ON EACH PANEL p�A'�1/TNO r °ado Sy 0/%- ROOF DISCONNECT Yes B A C K O F H O M E qa n or X No KW.-9.1 LBW Baty PERMIT RECEIVED X Yes POINTLOAD.• p # No 29.1 LBS PER FOOTING U y Measured By: LOAD ALL ROOF PATCHING WILL BE ALL CONDUIT,JUNCTION BOXESAND ROOF PENETRATIONS 2 314 MIN,AT NO Travis Roragen 2.5 LBS PER SQUARE FEET PER PANEL MADE WITH THE SAME MA TERM PV MODULES LABELED AND INSTALLED IN MORE THAN 48"O/C WITH 31/2"S.S. LAG BOLTS V =vent THAT CURRENTL Y&7575 ACCORDANCE WITH CEC CODES WITH#10 GROUND LUG5AND CLIPS Home OwnerApprova/ CA'L.l R-ox-N!i°t- ?-,o 13 C6 06-3 J°+rP P l-y Date: Page 1 of 5 MODULES ® sunpower 327 © 28 QTY ❑ ROOF CONDITION PITCH OF ROOF ROOF AZIMUTH Client Meyers INVERTER ® SUNNYBOY ❑ SOLECTRIA ❑ FRONIUS COMP 22 Address: 10146A/pine DR ❑ ® ❑ ❑ TILE good City: CUP"170 UNIRAC ❑ MGM E] LOW 77Z ❑ METAL Phone: CLYCKSYS ❑ ❑ ❑ NON COMP JOB #: 1-4054 PRO-SOLAR® ❑ HIGH TILT ❑ — ❑ TOTAL PANELS- 28 ALL CONDUCTORS IN CONDUIT PANEL 28 sunpower 327 ON THE EXTERIOR OF THE 200A NEMA 4, BUILDING SHALL BE WET RATED. 125A PVP JUNCTION BOX SUB aaolor 4 strings of ACTUAL PHOTOS PROVIDED PANEL USE-2-10AWG G 7HWN-2-10AWG INSEPAR4TESHEET 1 � l _ . — ' — . — . �. — . _ . - - - - -* - - - - - - - - - -� IF REQUIRED BY CITY/COUNTY oil I I BARE 8 ground wire 8 AWG GROUND WIRE I ALL C19NDUIT SHALL BE PAINTED 1 TO MATCH SURFACE OF I BUILDING WITH CAUTION I 1 LABELS Oa 10'IN7ERVALS I SERIES jacco r ALL WIRE EXPOSED ON ROOF ARALLEL 240V 30A AC dismnect i LINIQNG PV PANELS TOGETHER 1 STORY X I 1 TO BE USE/THWN-2 2 STORY® j R4 TED WIRE, 3 STORY O 1 — — — — 1 - - - - - - - - - - - - - - - - - - - - — — Hardware visible X YesD CUFFALL�IRETOBERUNINEMT No Buildin4 D I N'Fnt " AY 1. ROOF DISCONNECT Yes ��.. MAY 201 X No 4 x 100A new sub panels �;1 ,, r; r,-()OE C.C)M PERMIT RECEIVED X Yes 60OV30A DCd/scwn�� � +ANC& No 4 x suns - yboy 3000us-12 Measured By: 0 0 Travis Roragen NEC206 LABELS LEGENDS C� Grounding ROD PAGE 4. Home Owner Approval 4 xmain panels SINGLE LINE DIAGRAM Date: Page 2 of 5 MODULES ® sunpower327 ® 28 QTY ❑ ROOF CONDITION PITCH OF ROOF ROOF AZIMUTH Client Meyers inverter ® SUNNYBOY ❑ .SOLECTRIA ❑ FRONIuS COMP 22 Address: 10146 Alpine DR © ❑ ❑ TILE good City: cupertino UNIRAC ❑ ;0ccr ❑ LOW TILT ❑ METAL - Phone: CLYCKSYS ❑ ❑ ❑ NON COMP job# 1-4053 PRO-SOLAR ® ❑ HIGH TIL T ❑ ❑ TOTAL PANELS- 28 PVMODULERA77NGS PANEL II 2004 MODULE MAKE sunpower CONTENT: CAUTION - SOLAR ELECTRIC SYSTEM 125A MODULE E201327 BACKGROUND: RED SUB aC= MAX POWER POINT CURRENT(Imp) 5.98A LETTERING: WHITE PANEL MAX POWER VOLTAGE(Vmp) 54.7V ALL CAPITAL LETTERS OPENQRCUIT VOL TAGE(Voc) 64.9 V MINIMUM HEIGHT: 1-1/2" SHORT QRCUITCURRENT(Isc) 6.46A FONT: ARIAL OR SIMILAR NON-BOLD MAX SERIES FUSE(OCOP) 20A REFLECTIVE SURFACE AND MATERIAL SUITABLE FOR MAX POWER(Pmax) 327W EXTERIOR USE MAX VOLTAGE-DC 600V VOC TEMP COEFFIQENT 0.36%/C- LOCATION: ALL INTERIOR AND EXTERIOR CONDUIT,RACEWAYS, SERIES )000= ENCLOSURES AND CABLE ASSEMBLYS. PARALLEL INVERTER RATINGS EVERY 10' AT ALL TURNS, ABOVE AND BELOW 1 STORY X ALL PENETRATIONS, AT ALL DC COMBINER AND 2 STORY INVERTER NAME SUNNYBOY JUNCTION BOXES. 3 STORY INVERTER MODEL 3000TL-US MAX DC VOL TRATING 600V CONDUIT,WIRING,AND RACEWAYS WILL BE Hardware visible X Yes MAX POWER 320OW LUPE Q?SITED AS CLOSE AS POSSIBLE TO THE RIDGE, No NOMINAL A C VOL TA GE 240V �� Suildinq P=:,D +gpe0R VALLEY TO REDUCE TRIP HAZARDS AND ROOF DISCONNECT Yes MAXACCURRENT 15A MAXIMIZE VENTILATION OPPORTUNITIES X No MAX OCPDRATING 20A AA i_P._______. PERMIT RECEIVED X Yes REVIEV�Jz L) FC)k C()�_:)E (;(__J PL_iANGE No "'eviewed By Measured By: Travis Rora en Home OwnerApprma/ Date: Page 3 of 5 MODULES ® sun ower 327 ® 28 Q7Y ❑ ROOF CONDITION PITCH OF ROOF ROOF AZIMUTH Client Meyers INVERTER® SUNNYBOY ❑ r0LEC7)qIA ❑ FRONIUS COMP 22 Address: 10146 Alpine DR ® ❑ ❑ - TILE GOOD_ City: Cupertino UNIRAC aaaar LOW TILT - ❑ ❑ ❑ METAL Phone: CLYCKSYS ❑ ❑ ❑ NON COMP job# 1-4054 PRO-SOLAR® ❑ HIGH 7YL T ❑ ❑ ❑ TOTAL PANELS- 28 PANEL PANEL sPEQf7CATIONS 200A 125A Cj yA}y� L9V 2X VAO zx zoo 1.7. ' SUB JbI0101C 1JIM !»1 IT Ax lei s 1. 1�'� II— !7.0a 1 PANEL a '"d _ r- t ;Y X231 i T T T 2x 11.0 r, 1 ' ,Ev r SERIES ARALLEL 1 STORY X Quick Hook USA" - Curved Tile Mount QMCTH 2 STORY® .75 1101H SLOES Of$LOT SERRATED 3 STORY ..: T 6.57 - R11Ndinu _ Hardwarevisible X Yes ..56 ? _ 1 AM . MAY 1 1� r } '6 2 No J/TI'Et DME SEI SCRP R E V i E�Iv 1� r^ ROOF DISCONNECT Yes , too o I Reviewed Ery X NO SLIDE TO CC fD O LOCATION O PERMIT RECEIVED X Yes No 17E,v1 NO. DESCRIPTION CITY. S 3 Measured By: 1 BASE PLATE.QUICK HOOK USA,6'WIDE-606116.MRL 1 rA.7 2 LAG SCREW,HEY.HEAD.5/16-a111r.is- s s TTM: Quick MountPV unirac*Railings ] CI1IIcK HOOK USA.VERTICAL,6061-T6."LL 1 QMCTH:QUICK HOOK USA- i Travis Roragen CURVED TILE MOUNT CWeyffashing I SET SCREW.HEX SOCKET„10-327[5!6-,I"SS I SUBPUeSFSNG.QUICK HOOK USA v2-6'BASE. K I r K SILT ' 5 M7-3003-MILL T&G sheeting - 1 1 ~ A ure vSf. 3 0, 5 _^ 5116min/ag Molt w/2314" Embeded into roof rafter 2X8 RAFTERS Daft: Page 4 of 5 MODULES ® sunp0wer327 ® 28 QTY ❑ ROOF CONDITION PITCH OF ROOF ROOF AZIMUTH Client Meyers INVERTER ® SUNNYBOY ❑ SOLECTRIA ❑ FRONIUS COMP 22 Address: 10146 Alpine OR ® ❑ ❑ TILE GOOD City: Cupertno UNIRAC ❑ mar, ❑ LOW TILT ❑ METAL Phone: CLYCKSYS❑ ❑ ❑ NON COMP job# 1-4054 PRO-SOLAR ® ❑ HIGH TILT IQ TORCH DOWN ❑ TOTAL PANELS- 28 PANEL UPGRADE LABELS O 200A PER CEC 690-SM CO-SEC 9116 125A SUB PANEL RACEWAYS EVERY 10' AC DISCONNECT CAUTION SOLAR pig EE A CIRCUIT E OUTPUT CONNECT: RATED NOMINAL OPERATING AC VOLTAGE: XXXVOLTS MAIN SERVICE PANEL D WARNING TWO POWER SOURCES PHOTOVOLTAIC DISCONNECT LOCATED AT FADERESISTANT DICONNECT LABEL SERIES EMERGENCY DISCONNECT AC DISCONNECT WARNING: PARALLEL B ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. 1 STORY x F TERMINALS ON BOTH LINE AND 25TORY LOAD SIDES MAY BE ENERGIZED 35TORY IN THE OPEN POSITION Hardware visible X Yes PERMANENTPLAC4RD-EXTERIOR/INTERIOROFMAIN No CAUTION SOLAR PV SYSTEM INSTALLED. PHOTOVOLTAIC SYSTEM DC ROOF DISCONNECT Yes C WHEN POWER IS DISCONNECTED, SOLAR DISCONECT ALL SOLAR CONDUITS,INTERIOR/EXTERIOR X No PANELS AND WIRING MAY REMAIN OPERATING CURRENT AMP CAUTION: SOLAR PV WIRING MAY PERMIT RECEIVED x Yes ENERGIZED DURING DAYLIGHT HOURS SHORT CIRCUIT CURRENT AMP G REMAIN ENERGIZED AFTER No OPERATIING VOLTAGE VDC DISCONNECT DURING DAYLIGHT Measured By:❑ MAX SYSTEM VOLTAGE VDC HOURS Travis Roragen Home OwnerApprova/ :UI- c� i 4i�i�3 Date: uiAna [_)epartmeriPage 5 of 5 MAY 13 2014 REVIEViEb t UF? C-;'�OE i"OMIPUANCE