Loading...
B-2017-1574 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS i CONTRACTOR: PERMIT NO:B-2017-1574 10707 AMULET PL CUPERTINO,CA 95014-1303(326 43 064) SOLARCITY CORPORATION SAN MATEO,CA 94402 OWNER'S NAME: DATE ISSUED:09/14/2017 OWNER'S PHONE: PHONE NO:(650)963-5100 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-10:C-46:B Lic.#888104 Contractor SOLARCITY CORPORATION Date 12/31/2018 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N)13 PANEL ROOF MOUNTED PV SYSTEM(3.9 KW) I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the 'performance of the work for which this permit is issued. '' I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$10000.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 326 43 064 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR • Additionally,the applicant understands and will comply with all non-point source _ Date 9/14/2017 Issued by:AbbyAyende Date:09/14/2017 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS: following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is 1. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for• inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:9/14/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Se tions 5505,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. der or authorized agent: APPLICANT CERTIFICATION Date:9/14/2017 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance' relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Licensed Signature Date 9/14/2017 Professional - ► r51if ALTERNATIVE ENERGY PERMIT APPLICATION AE COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION s, 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333•building at7.cupertino.orq PROJECT ADDRESS 1 010 4frttA Ler PL APN# "bap_„_ L Lb „out! OWNER NAME a /�q— - ics/A- PHONE O • •�v �JQ Apt�-C3 L'F b'� corn `i"l C- ec - STREET ADDRESS (lV CITY, STATE,ZIP FAX CONTACT NAME Gerry Igtanloc PHONE 650-759-8042 E-MAIL gigtanloc@tesla.com STREET ADDRESS 391 Foster City Blvd. CITY,STATE,ZIP Foster City FAX ❑OWNER 0 OWNER-BUILDER ❑ OWNER AGENT IR CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME SolarCi Corp. ICENSE NUMBER 888104 LICENSE TYPE C10,C46,B BUS.LIC# ty p COMPANY NAME SolarCity Corp. E-MAIL gigtanloc@tesla.com FAX STREET ADDRESS 3055 Clearview Way CITY,STATE,ZIP San Mateo, CA 94402 PHONE 650-759-8042 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# ' COMPANY NAME E-MAIL FAX I - STREET ADDRESS CITY,STATE,ZIP PHONE i USE OF [X SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE:' ❑ Commercial URBAN INTERFACE AREA ❑ Yes al No FLOOD ZONE 0 Yes E No SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: L 3 KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: J� 9(� 0 806 DESCRIPTION OF WORK Install( (3 ) roof mounted solar panels. (3o( )KW. (lUc,, sub-- /We C.- . C W)� RECEIVED BY::e By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bd co tructi n. I authorize representatives of Cupertino to enter the above-identifiedd prope /for inspection purposes. Signature of Applicant/Agent: Date: :. I 1 SUPPLEMENTAL INFORMATION REQUIRED •OFFICE USE ONLY ❑ OVER-THE-COUNTER aa. oa; E"_ EXPRESS " , R} ;0 STANDARD ; a ❑ LARGE ❑ MAJOR • PVApp 2011.doc revised 03/16/11 � 3o #/R SMOKE I CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE yl%.p4 COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPEIiTINO 10300 TORRE AVENUE • CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinppcuiiertino.orq Permit 1+I©.f3-(2cSf? /17 4 1 Address 10707 Amulet,PI Cupertino, CA 95014 (#aAlarms(Smoke: 5 (Carbon Monoxide PERMIT.CANNOT BE.FINALED.AND:COMPLETED UNTII THIS.CERTIFICATE. . AS BEE1 9'9,1 D::RETUj N TOT E Bl DIN DWI ION° PURPOSE This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314,2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi-family.dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00,CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms he installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity-of the X X bedroom(s) On every level of a dwelling unit including basements X X • Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply In dwelling units with no commercial power supply, alarm(s)may be solely battery operated. In existing dwelling units,alarms are permitted to be solely battery operated where repairs or alterations do not result in the.removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl space.Refer to CRC Section R314 and CBC Sections 907.2.114 and 420.6.2.An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above-referenced property,I hereby certify that the alarm(s)referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms have been tested and are operational, as of the date signed below r .. I have read and agree to c mply wi the terms and conditions of this statement Owner(or Owner Agent's)Name: Udayan Palekar (signator .:............. . . tale; IDtii .E Contractor Name: Si,nature Lic.# Date: .......... Smoke and CO form.doe revised U3118/14 INDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * * * * * * * * * * * * * LICENSE GENERAL NOTES SEAN HATCH 09/13/17 09/13/17 B-2017-1574 Abby Ayende Front Of House 3' FSB3' FSB 3' FSB 3' FSB A Pitch5/12MP1MP4MP3MP5MP6 Scale: 1/8" = 1' SITE PLAN 0 1' 8' 16' LEGEND MP1 20 108 20 108 Comp Shingle 2 Stories SEAN HATCH 09/13/17 S1 SIDE VIEW OF MP1 NTS X-SPACING PORTRAIT LANDSCAPE STORIES: ROOF AZI X-CANTILEVER Y-SPACING Y-CANTILEVER PITCH ARRAY AZI PITCH NOTES X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. MP1 108 20 108 20 Comp Shingle - Skip Sheathing 22x6 @ 24" OC 2x6 @24" OC 72" 24" 39" 0" 48" 20" 0"64" RAFTER C.J. A Scale: 1 1/2" = 1' STANDOFFS1 SEAN HATCH 09/13/17 VENT SPANNING DETAIL ” “ ² SEAN HATCH 09/13/17 LICENSEMODULE SPECS INV 1 INVERTER SPECS GENERAL NOTES MAIN PANEL SPECS GROUND SPECS INV 2 INV 3 AC DC N A B EGC/GEC GEC B V240 L2 L1 N EGC/ GEC GND N ADJUST MIN. ACTIVATION VOLTAGES! Inverter 1 PAR DC+ EGC DC- A EGC DC- DC+ MP 1: 1x13 Vstart = 200V A B POI 1 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC1 2 Voc* = VDC Isc = ADC Vmp = VDC Imp= ADC2 3 Vmp = VAC Imp= AAC 3 4 Vmp = VAC Imp= AAC 4 SEAN HATCH 09/13/17 LB-130089-10X Per Code: CEC 690.31.G.3 Label Location: (C)(IC)(CB) LB-050081-10X Per Code: CEC 690.13.B Label Location: (DC) (INV) LB-030042-10X Per Code: CEC 690.53 Label Location: (DC) (INV) LB-070004-10X Per Code: CEC 690.5(C) Label Location: (INV) LB-050082-10X Per Code: CEC 690.13.B Label Location: (AC) (POI) LB-040007-10X Per Code: CEC 690.54 Label Location: (AC) (POI) LB-040013-10X Label Location: (AC) LB-070005-10X Per Code: CEC 690.17.E Label Location: (DC)(CB) LB-060046-10X Per Code: CEC 690.54; CEC 690.17 Label Location: (POI) LB_040108_10X Per Code: CEC 690.56(C) Label Location: (INV) LB-040009-10X Per Code: CEC 705.12.D.3 Label Location: (POI) LB-070039-10X Per Code: CEC 705.12.D.2.b Label Location: (POI) LB_200127_10X Per Code: CEC 705.12.D.2.c LB-070016-10X Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED Label Location: (DC)(INV)(CB) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set SEAN HATCH 09/13/17 HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP SEAN HATCH 09/13/17 HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP for composition shingle roofs DQ\ PDQXIDFWXUHU FHUWL¿HG DV ³7\SH ´ RU ³7\SH ´ 6SHFL¿FDWLRQV HDFK SURGXFW 7KH HQGXVHU GRFXPHQWDWLRQ VKLSSHG ZLWK =HS 6RODU¶V SURGXFWV FRQVWLWXWHV WKH VROH VSHFL¿FDWLRQV UHIHUUHG WR LQ WKH SURGXFW ZDUUDQW\ 7KH FXVWRPHU LV VROHO\ UHVSRQVLEOH IRU YHULI\LQJ WKH VXLWDELOLW\ RI =HS6RODU¶V SURGXFWV IRU HDFK XVH 6SHFL¿FDWLRQV DUH VXEMHFW WR FKDQJH ZLWKRXW QRWLFH 3DWHQWV DQG $SSV ]VSDWVFRP 1H[W/HYHO 39 0RXQWLQJ 7HFKQRORJ\ ]HSVRODUFRP Part No. 850-1633 Listed to UL 2703 and UL 2582 &DSWXUHG :DVKHU /DJ Part No. 850-1631-001 850-1631-003 )ODVKLQJ $FFHVVRU\ Part No. 850-1634 Listed to UL 2703 and UL 2582 $UUD\ 6NLUW Part No. 850-1608 or 500-0113 Listed to UL 2703 Part No. 850-1606 or 850-1421 Listed to UL 2703 (QG &DS Part No. (L) 850-1586 or 850-1460 (R) 850-1588 or 850-1467 Part No. 850-1509 Listed to UL 1565 *URXQG =HS 9 Part No. 850-1511 Listed to UL 467 and UL 2703 Part No. 850-1388 or 850-1613 Listed to UL 2703 /HYHOLQJ )RRW Part No. 850-1397 Listed to UL 2703 SEAN HATCH 09/13/17 ® ® ® ® SEAN HATCH 09/13/17 0~+5W POSITIVE POWER TOLERANCE 60 CELL MONOCRYSTALLINE MODULE 275-305W POWER OUTPUT RANGE 18.6% MAXIMUM EFFICIENCY IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001: Quality Management System ISO 14001: Environmental Management System ISO14064: Greenhouse gases Emissions Verification OHSAS 18001: Occupation Health and Safety Management System Comprehensive Products And System Certificates Mono Multi Solutions Certified to withstand the most challenging environmental conditions • 2400 Pa wind load • 5400 Pa snow load • 35 mm hail stones at 97 km/h Standard Step WarrantyTrina Linear Warranty Additional value from Trina Solar’s linear warranty Guaranteed Power80% 90% 100% 97% Years 5 10 15 20 25 LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty · 25 Year Linear Power Warranty Maximize limited space with top-end efficiency • Up to 186 W/m² power density • Low thermal coefficients for greater energy production at high operating temperatures Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyond certification requirements • PID resistant • 100% EL double inspection EU-28 WEEECOMPLIANTRECYCLABLEPACKAGING Founded in 1997, Trina Solar is the world's leading comprehensive solutions provider for solar energy. we believe close cooperation with our partners is critical to success. Trina Solar now distributes its PV products to over 60 countries all over the world. Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners. THE MODULE I-V CURVES OF PV MODULE(305W) Voltage(V)Current (A) 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 1000W/m² 800W/m² 600W/m² 400W/m² 200W/m² FRAMED 60-CELL MODULE TSM-DD05A.18(II) 280-305W PRODUCTS POWER RANGE CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. © 2017 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to change without notice. Version number: TSM_EN_2017_A www.trinasolar.com P-V CURVES OF PV MODULE(305W) Voltage(V)Power (W) 50 100 150 200 250 350 300 1000W/m² 800W/m² 600W/m² 400W/m² 200W/m² ELECTRICAL DATA (STC) STC: Irradiance 1000W/m², Cell Temperature 25°C, Air Mass AM1.5. *Measuring tolerance: ±3%. Peak Power Watts-PMAX (Wp)* Power Output Tolerance-PMAX (W) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) Module Efficiency m (%) 0 ~ +5 305 32.9 9.28 40.2 9.72 18.6 290 32.2 9.01 39.5 9.50 17.7 295 32.5 9.08 39.7 9.55 18.0 300 32.6 9.19 39.9 9.64 18.3 275 31.4 8.76 38.7 9.26 16.8 280 31.7 8.84 39.0 9.35 17.1 285 31.8 8.97 39.3 9.45 17.4 (DO NOT connect Fuse in Combiner Box with two or more strings in parallel connection) 44°C (±2°C) - 0.39%/°C - 0.29%/°C 0.05%/°C TEMPERATURE RATINGS NOCT(Nominal Operating Cell Temperature) Temperature Coefficient of PMAX Temperature Coefficient of VOC Temperature Coefficient of ISC MAXIMUM RATINGS Operational Temperature Maximum System Voltage Max Series Fuse Rating -40~+85°C 1000V DC (IEC) 1000V DC (UL) 15A (Please refer to product warranty for details) WARRANTY 10 year Product Workmanship Warranty 25 year Linear Power Warranty PACKAGING CONFIGURATION Modules per box: 30 pieces Modules per 40’ container: 840 pieces NOCT: Irradiance at 800W/m², Ambient Temperature 20°C, Wind Speed 1m/s. ELECTRICAL DATA (NOCT) Maximum Power-PMAX (Wp) Maximum Power Voltage-VMPP (V) Maximum Power Current-IMPP (A) Open Circuit Voltage-VOC (V) Short Circuit Current-ISC (A) 209 29.4 7.10 36.3 7.55 212 29.6 7.17 36.6 7.63 216 29.9 7.23 36.7 7.67 227 30.6 7.42 37.3 7.84 220 30.2 7.28 36.9 7.71 223 30.4 7.35 37.1 7.78 205 29.2 7.02 36.0 7.48 Solar Cells Cell Orientation Module Dimensions Weight Glass Backsheet Frame J-Box Cables Connector Fire Type MECHANICAL DATA Monocrystalline 156.75 × 156.75 mm (6 inches) 60 cells (6 × 10) 1650 × 992 × 40 mm (65.0 × 39.1 × 1.57 inches) 19.6 kg (43.1 lb) 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass White Black Anodized Aluminium Alloy IP 65 or IP 67 rated Photovoltaic Technology Cable 4.0mm² (0.006 inches²), 1000 mm (39.4 inches) MC4 UL 1703 Type 2 for Solar City DIMENSIONS OF PV MODULE(mm/inches) 992/39.11650/65.0A 941/37.0 180/7.1 150/5.9 990/39.0 330/13.012-Drain Hole 1200/47.2±10/0.39Junction Box Nameplate 6-Ø 4.3 Grounding Hole 4-Ø 9x12 Installing Hole A Back View 40/1.57 40/1.57 35/1.3840/1.5711/0.43 Silicon Sealant Laminate Frame (A-A) SEAN HATCH 09/13/17 Solar inverters ABB string inverters PVI-3.0/3.6/3.8/4.2-TL-OUTD(-M) 3.0kW to 4.2kW This family of single-phase string inverters complements the typical number of rooftop solar panels enabling homeowners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub-arrays oriented in different directions, or unbalanced strings (for example: East and West). The dual-input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high- efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0 percent. The wide input voltage range makes the inverter suitable to low-power installations with reduced string size. This rugged, outdoor inverter has been designed to be a completely sealed unit, to withstand the harshest environmental conditions. Highlights ŨSingle-phase and three-phase output grid connection ŨWide input-voltage range for increased stringing flexibility and energy harvesting ŨThe high-speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting ŨOutdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions ŨIntegrated DC disconnect switch in compliance with international Standards (-S Version) 2 ABB solar inverters | Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US General specifications Nominal output power 3000W 3600W 3300 W 3800W 4200W Maximum output power wattage 3000 W 33001 W 3300 1 W 3600 W 40001 W 40001 W 3300 W 4200 1 W 42001 W 4200 W 46001 W 46001 W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V Input side (DC) Number of independent MPPT channels Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage (Vmax) 600V Start-up voltage (Vstart) 200V (adj. 120-350V) Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V Operating MPPT voltage range  Z 8UVCTV  8 ű8 Maximum current (Idcmax) for both MPPT in parallel 20A 32A 32A 32A Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per channel 12.5A 20.0A 20.0A 20.0A Number of wire landing terminals per channel 2 pairs Array wiring termination Terminal block, pressure clamp, AWG20-AWG6 Output side (AC) Grid connection type 1Ø/ 2W Split- Ø/3W 1Ø/ 2W 1Ø/ 2W Split- Ø/3W 1Ø/ 2W 1Ø/ 2W Split- Ø/3W 1Ø/ 2W 1Ø/ 2W Split- Ø/3W 1Ø/ 2W Adjustable voltage range (Vmin-Vmax) (V)183- 228V 211- 264V 244- 304V 183- 228V 211- 264V 244- 304V 183- 228V 211- 264V 244- 304V 183- 228V 211- 264V 244- 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current (Iac,max) 14.5A 14.5A 12.0A 17.2A 16.0A 16.0A 16.0A 16.0A 16.0A 20.0A 20.0A 20.0A Power factor > 0.995 (adjustable to ±0.8) Total harmonic distortion at rated power < 2% Grid wiring termination type Terminal block, Pressure clamp, AWG20-AWG6 Input protection devices Reverse polarity protection Yes Over-voltage protection type Varistor, 2 for each channel PV array ground fault detection Pre start-up RISO and dynamic GFDI (requires floating arrays) Output protection devices Anti-islanding protection Meets UL1741 / IEEE1547 requirements Over-voltage protection type Varistor, 2 (L1 - L2 / L1 - G) Maximum AC OCPD rating 20A 20A 15A 25A 20A 20A 20A 20A 20A 25A 25A 25A Efficiency Maximum efficiency 96.9% 97% 97% 97% CEC efficiency 96% Operating performance Nighttime consumption < 0.6WRMS Stand-by consumption < 8WRMS Communication User-interface 16 characters x 2 lines LCD display Remote monitoring (1xRS485 incl.) VSN700 Data Logger (opt.), VSN300 Wifi Logger Card (opt.) Revenue grade meter ANSI C12.20, 0.5% accuracy class (-M models) Environmental Ambient air operating temperature range -13°F to +140°F (-25°C to 60°C) with derating above 122°F (50°C) Ambient air storage temperature range -40°F to +176°F (-40°C to +80°C) Relative humidity 0-100% RH condensing Acoustic noise emission level < 50 db (A) @1m Maximum operating altitude without derating 6560ft (2000m) 1. Capability enabled at nominal AC voltage and with sufficient DC power available. Additional highlights ŨRS-485 communication interface (for connection to laptop or data logger) ŨAvailable with the optional VSN300 Wifi Logger Card for easy and affordable wireless monitoring ŨCompliant with NEC 690.12 when used with ABB‘s Rapid Shutdown device ŨComes standard with DC Arc Fault Circuit Interruptor (AFCI) to comply with NEC 690.11 ŨAvailable with optional revenue grade meter ANSI C12.20, 0.5% accuracy class (-M version) SEAN HATCH 09/13/17 Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD | ABB solar inverters 3 Block diagram of PVI-3.0/3.6/3.8/4.2-TL-OUTD Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Mechanical specifications Enclosure rating NEMA 4X Cooling Natural convection Dimensions H x W x D 33.8 x 12.8 x 8.7in (859 x 325 x 222mm)2 Weight <47.3lb (21.3kg)2 Shipping weight < 60lb (27.0kg)2 Mounting system Wall bracket Conduit connections2 Bottom: (2) pre-drilled opening for ¾ inch conduits and concentric markings for 1 inch (both sides) and 1½ inch conduit (DC side only) Sides: (2) pre-drilled opening for ¾ inch conduits with concentric markings for 1 inch (both sides) and 1½ inch conduit (DC side only) Back: (2) concentric markings for ¾ inch and 1 inch conduits DC switch rating (per contact) (A/V) 25/600 Safety and Compliance Isolation level Transformerless (floating array) Safety and EMC standard UL 1741 with Supplement SA, IEEE1547, IEEE1547.1, CSA-C22.2 N. 107.1-01, UL1998 UL 1699B, FCC Part 15 Class B Safety approval cCSAus or cTUVus Regional Compliance Tested to UL 1741 SA, Rule 21, HECO, NEC 2014 690.11, NEC 2014 690.11.12 with ABB rapid shutdown device Available models With DC switch, wiring box, arc fault detector and interrupter PVI-3.0-OUTD-S- US-A PVI-3.6-OUTD-S- US-A PVI-3.8-OUTD-S- US-A PVI-4.2-OUTD-S- US-A With DC switch, wiring box, arc fault detector and interrupter, and revenue grade meter PVI-3.0-OUTD-S- US-M-A PVI-3.6-OUTD-S- US-M-A PVI-3.8-OUTD-S- US-M-A PVI-4.2-OUTD-S- US-M-A Rapid shut down power supply Yes Yes Yes Yes 2. When equipped with optional DC switch and wiring box. All data is subject to change without notice 5,00% 10,00% 15,00% 20,00% 25,00% 30,00% 35,00% 40,00% 45,00% 50,00% 55,00% 60,00% 65,00% 70,00% 75,00% 80,00% 85,00% 90,00% 95,00% 100,00% 215 250 300 345 400 480 [%] of Rated Power MPPT Voltage [V] 97,0 96,6 96 94,8 94,4 95,2 94 93,6 93,2 92,8 92,4 92 91,6 95,6 97,0 96,4 96,4 96 95,2 96 95,2 96,2 96 94 94 92 92 92 91 92 93 94 95 96 97 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 'HƂEKGPEy, %  QH 4CVGF 1WVRWV 2QYGT 200 Vdc 340 Vdc 480 Vdc PVI-4.2-OUTD-US PVI-4.2-OUTD-US IN1 IN2 + - + - IN1 + - IN2 + - MPPT 2 (DC/DC) MPPT 1 (DC/DC) BULK CAPS INVERTER (DC/AC) LINE FILTER GRID PARALLEL RELAY L1 L2 PE RESIDUAL CURRENT DETECTION DC/DC DSP CONTR. DC/AC DSP CONTR. μP CONTROL CIRCUIT RS485 + T/R - T/R RTN REMOTE CONTROL* + R - R ALARM N.C N.O C GROUND FAULT DETECTION N * Remote control function not available on -A version IN1 IN2 + - + - DC AFDI IN1.1(+) IN1.2(+) IN1.1(-) IN1.2(-) IN1 IN2 + - + - IN2.1(+) IN2.2(+) IN2.1(-) IN2.2(-) IN1 IN2 + - + - WIRING BOX IN1 IN2 + - + - 9AKK106103A4852 REV G-RGM EN 01.06.2017 #16634Support and service ABB supports its customers with a dedicated, global service organization in more than 60 countries, with strong regional and national technical partner networks providing a complete range of life cycle services. For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com © Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice. This inverter is marked with one of the two certification marks shown here (TuV or CSA). SEAN HATCH 09/13/17