Loading...
B-2017-1657 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2017-1657 20833 HANFORD DR CUPERTINO,CA 95014-1823(326 30 073) SLINGSHOT POWER INC LOS ALTOS,CA 94022 OWNER'S NAME: MANNE PRABHAKAR S AND LAXMI K DATE ISSUED:09/26/2017 OWNER'S PHONE:408-839-4074 PHONE NO:(650)308-9055 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-46 Lic.#984488 Contractor SLINGSHOT POWER INC Date 06/30/2019 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. JOB DESCRIPTION: (N)14-PANEL ROOF MOUNTED PV SYSTEM(4.55 KW);(N)EV I hereby affirm under penalty of perjury one of the following two declarations: CHARGING STATION(50 AMPS)-GARAGE 1. 1 have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the rformance of the work for which this permit is issued. itave and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$15200.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 326 30 073 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. lure /I _ 1*•�'�!-i j��e ate 9/26/2017 Issued by:Abby Ayende Date:09/26/2017 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS; following two reasons: All roofs shall be inspected prior to any roofing material beingynstalled.If a roof is 1. I,as owner of the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Date:9/26/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. 1 have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE z. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall nn be deemed revoked. '/ , 1 I, —....as--....—...---- �Mll�r or authorized agent:_ /Ail*��/ � �s APPLICANT CERTIFICATION Date:9/26/2017 I certify that I have read this application and state that the above information is CONST' . e • ENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Signature Date 9/26/2017 Licensed Professional b-Loi - - lui l- \ /�' ALTERNATIVE ENERGY PERMIT APPLICATION (704 , ir COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISIONAE 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 vS`,,,\ CUPERTINO (408)777-3228• FAX(408)777-3333•buildinq aacuoertino.orq PROJECT ADDRESS APN# 20833 Hanford Drive ' 2.(.0.. `0 3 OWNER NAME Prabhakar Manne PHONE 408-839-4074 E-MAIL spmanne@gmail.com STREET ADDRESS 20833 Hanford Drive CITY,sptino, CA 95014 FAX CONTACT NAME Linda Dodge PHONE 669-213-9211 E-MAILldodge@slingshotpower.com STREET ADDRESS 164 Main Street CITY,STATE,ZIP Los Altos, CA 94022 FAX 408-887-0345 ❑OWNER 0 OWNER-BUILDER 0 OWNER AGENT 0 CONTRACTOR ❑;CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME Ravi Chiruvolu ,IdCEJ'$gp(UMBER LICENSE TYPE C46 Bus.LIC#403538 COMPANY NAME Slingshot Power `Jj���{{��}}E-�jSMAIL ldodge@slingshotpower.com FAX650-887-0345 STREET ADDRESS 164 Main Street CITY,STATE,ZIP Los Altos, CA 94022 PHONE 650-209-0171 ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF Cf SFD or Duplex 0 Multi-Family PROJECT IN PROJECT IN STRUCTURE: 0 Commercial� ELECWILDLANURBAN 0 Yes 13 No FLOOD ZONE 0 Yes No 7 SOLAR PANELS ar TRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: i Lt KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: $15,200.00 DESCRIPTION OF WORK Installation of(14) Panasonic VBHN325SA16 Modules and (1) Solar Edge 5000/P300 inverter mounted on the Roof of the Residence Size of project 4.32 KW 1 a\GVI Tl() Gt ov1 ( awl ) RECEIVED BY: /��� y- 4k... 1 By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property ownb all. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: . . Date: 9/25/17 SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY y 0 OVER-THE-COUNTER Q. F 0 EXPRESS U 0 STANDARD U 0 LARGE a. 0 MAJOR PVApp_2011.doc revised 03/16/11 Fl SMOKE / CARSON MONOXIDE ALARMS 11 OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinq(�cupertino.orq PERMIT CANNOT BE FINALED UNTIL THIS CERTIFICATE.HAS BEEN ',-:':;?-`'`.;'!';' ''''-:COMPLETED;SIGNED,AND RETURNED TO THE BUILDINFG DIVISION• ( PURPOSE .This affidavit is a self-certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314,R315,2016 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-familyand multi-family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations,or repairs to existing dwelling units exceeds $1000.00, CRC Section R314,R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the X X bedroom(s)-(Smoke alarms shall not be located within 3 feet of bathroom door) On every level of a dwelling unit including basements and habitable attics X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do notcontain fuel-burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply:In dwelling units with no commercial power supply, alarrn(s)may be solely battery operated. In existing dwelling units, alarms are permitted tobe solely battery operated where repairs or alterations.do .. not result in the removal of wall and ceiling finishes or there is no access by means of attic,basement or crawl• space.Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2.An electrical permit is required for: alarms which must be connected to the building wiring. As ownerof the above-referenced property,I hereby certify that the alarm(s)referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building .. . and California Residential Codes.The alarms specified below have been tested and are operational, as of the date signed Blown 1/2 Address: 0 `� k--kai,\ Og--) Permit No. /3-20-3-. - / (05q — Specify Number of Alarms: #Smoke Alarms: I1 . #Carbon Monoxide Detectors: _ • /have read and agree to comply with the terms and conditions of this statement Owner(or Owner Agent's)Name: �p� J% v ! (�/� Signature/�f'.TQ( .4.R (c, Date: 'ontracfor Name:` S I I i1(i Wii. pot P✓ Signature is" -� Lic.# Date: 7/7// / Smoke and COform.doc revised 01/10/2017 GENERAL NOTES 1. THIS SYSTEM IS GRID-TIED WITH A UL LISTED POWER CONDITIONING INVERTER 2. THIS SYSTEM HAS NO BATTERIES. NO UPS 3. ALL WORK SHALL COMPLY WITH THE 2016 CALIFORNIA BUILDING CODE AND THE 2016 CALIFORNIA RESIDENTIAL CODE 4. ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2016 CALIFORNIA ELECTRIC CODE 5. LOCAL UTILITY SHALL BE CONTACTED PRIOR TO ENERGIZATION OF THE SYSTEM ELECTRICAL NOTES 1. A NATIONALLY RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART 110.3 2. ALL EXTERIOR EQUIPMENT SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET CONDITIONS 3. BACKFEED BREAKER MUST BE LOCATED AT THE OPPOSITE END OF BREAKER OR LUGS PROVIDING POWER FROM THE UTILITY 4. DC CONDUCTORS ENTERING A BUILDING WILL BE RUN IN METALLIC RACEWAYS TO THE FIRST ACCESSIBLE MEANS OF DISCONNECTION PER ART 690.31(E) 5. ALL CONDUCTORS SHALL BE PROVIDED WITH STRAIN RELIEF UPON ENTRY INTO ENCLOSURES. 6. EACH UNGROUNDED CONDUCTOR SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER ART 210.5 7. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS SHALL REMAIN ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE PROVIDED PER ART 690.17 8. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED PER ART 690.47 AND 250.66(B) 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL-LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL-LISTED HARDWARE 10.ALL METALLIC COMPONENTS SHALL BE GROUNDED VIA ELECTRIC GROUNDING CONDUCTORS AND GROUNDED AT THE MAIN SERVICE 11.2014 NEC 690.12 RAPID SHUTDOWN COMPLIANT ABBREVIATIONS A AMPERE AC ALTERNATING CURRENT ART ARTICLE BLDG BUILDING STRUCTURE CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRIC METALLIC TUBING GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Icont CONTINOUS CURRENT Imp MAX POWER CURRENT Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MAX MAXIMUM MIN MINIMUM N NEUTRAL NEC NATIONAL ELECTRIC CODE NTS NOT TO SCALE (N) NEW OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PTC PVUSA TEST CONDITIONS PV PHOTOVOLTAIC PVC POLYVINYL CHLORIDE SCH SCHEDULE SS STAINLESS STEEL STC STANDARD TES CONDITIONS TYP TYPICAL UPS UNINTERRUPTIPLE POWER SUPPLY V VOLT Vmp MAX POWER VOLTAGE Voc OPEN CIRCUIT VOLTAGE W WATT SHEET INDEX PV01 COVER SHEET PV02 SITE PLAN PV03 ARRAY DETAILS PV04 LINE DIAGRAM PV05 ELECTRICAL CALCULATIONS LBLS LABELS DATA SHEETS ATTACHED OPTIMIZER NOTES 1. SYSTEM IS UNGROUNDED 2. OUTPUT CHARACTERISTICS ARE INDEPENDENT OF TEMPERATURE 3. INVERTER INPUT VOLTAGE IS CONSTANT AT 350V 4. INVERTER INPUT CURRENT IS CALCULATED WITH OHMS LAW WITH VOLTAGE CONSTANT AT 350V AND POWER FROM THE ARRAY'S Pstc 5. INVERTER INPUT CURRENT MAX IS 15A BASED ON OPTIMIZER TOPOLOGY VICINITY 4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV01JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- COVER PAGE SCOPE OF WORK SLINGSHOT POWER IS TO INSTALL A ROOF MOUNTED PV SOLAR ARRAY(S) INCLUDING A NEMA 14-50R OUTLET FOR FUTURE EV CHARGING STATION. CONTRACTOR ADDRESS SLINGSHOT POWER 164 MAIN ST LOS ALTOS, CA 94022 800.887.9414 CSLB #C-46 984488 AHJ: CITY OF FREMONT UTILITY: PG&E HOA: N/A Abby Ayende 09/26/17 09/26/17 B-2017-1657 Abby Ayende MP3 MP2 00 0 INV AC M B HANFORD DR DRIVEWAY FRONT OF THE HOUSE EV SITE PLAN4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV02JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- CONDUIT RUN ON THE ROOF IN COMPLIANCE WITH 2016 CEC 690.31 & 2016 CRC R331.3 (EXACT RUN TBD AT INSTALL). Scale: 3/32" = 1' SITE PLANA N W S E 2014 NEC 690.12 RAPID SHUTDOWN COMPLIANT Abby Ayende 09/26/17 MP3 MP2 00 0 INV AC M B 6' 20'-10" 3ft FSB 18in FSB18in FSB27'-10" EV (E) 2x RAFTER (E) DECKING (N) 5/16" SS LAG SCREW 2_1/2" EMBED. MIN (N) EVEREST COMP EVERFLASH (N) L-FOOT EVEREST (N) SOLAR RAIL EVEREST CR-48S (N) SOLAR MODULE WITH EVEREST CLAMPS ARRAY DETAILS Scale: 1/8" = 1' ARRAY PLANA Scale: NTS ARRAY DETAILB 4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV03JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- PV METER (N) INVERTER STANDOFF / ROOF ANCHOR LOCKED GATE PVM (N) SUB-PANEL AC DISCO INV SP AC DC DISCODC INTERIOR EQUIPMENT IS DASHED--- X UNLOCKED GATE0 PV RAIL INTERIOR CONDUIT CONDUIT (E) MAIN SERVICE PANELM JUNCTION / COMBINER BOXB LEGEND MP2 ROOF PITCH: 4 : 12 ( 18 ° ) AZI: 180 ° MATERIAL: Comp Shingle STORY: 1 TOTAL: 6 MODULES 8 MOUNTS MP3 ROOF PITCH: 4 : 12 ( 18 ° ) AZI: 270 ° MATERIAL: Comp Shingle STORY: 1 TOTAL: 8 MODULES 12 MOUNTS A PV06 B PV06 (N) NEMA 14-50R WALL OUTLET FOR FUTURE EV CHARGER 2014 NEC 690.12 RAPID SHUTDOWN COMPLIANT Abby Ayende 09/26/17 EGC DC- DC+ N L2 L1 EGC GEC AB C N G (1) INVERTER 3800W, 240V, 99% EFF SOLAREDGE SE3800H-US 2014 NEC 690.12 COMPLIANT N G (1) AC DISCONNECT 30A, 240V, 2P, NEMA 3R EATON DG221URB M 240/120V SINGLE PHASE UTILITY SERVICE (E) MAIN SERVICE 200A, 240/120V, 1ɸ, 3W MURRAY OVERHEAD SERVICE FEED Meter No.: 1007368204 A B (N) 20A/2P (E) 200A/2P (E) LOADS + -+ - + - + - 14 MODULE STRING (14) PV MODULES 325 W, 306.5 W PTC PANASONIC VBHN325SA16 (14) PV OPTIMIZERS 400W, 15Amax, 80Vmax SOLAREDGE P400 CEC-AC RATING: 3.248 kW (2) #10 TYPE PV, (1) #6 BARE EGC N/A A B C CONDUCTORS CONDUIT # 2' LENGTH DC: Vmax=500, Vmp=350, Imax=15, Imp=13 PROPERTIES DC: Vmax=500, Vmp=350, Imax=15, Imp=133/4" EMT 50' (2) #10 THWN-2, (1) #8 EGC NOTES SEE ELECTRICAL NOTES AND OPTIMIZER NOTES ON PAGE 1 2014 NEC 690.12 RAPID SHUTDOWN COMPLIANT (2) #10 THWN-2, (1) #10 N, (1) #8 EGC/GEC 3/4" EMT 5' AC: V=240, I=16 C JUNCTION BOX(S) NEMA 3R (N) 50A/2P TO (N) NEMA 14-50 RECEPTACLE FOR FUTURE EV CHARGER D D (3) #8 THWN-2, (1) #8 EGC/GEC 3/4" EMT 5' N G LINE DIAGRAM4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV04JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- 120% RULE (MSP): MAINS RATING = 200A 200A * 1.2 = 240 AMPS ALLOWABLE TOTAL OF BREAKERS FEEDING BUS BAR = 220A 120% OF BUS NOT EXCEEDED (NEC 705.12(D)(2)) GEC BONDED DIRECTLY TO (E) GROUNDING ELECTRODE. ALL AVAILABLE ELECTRODES SHOULD BE USED PER CEC 250.50 Abby Ayende 09/26/17 ELEC CALCS4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV05JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- Abby Ayende 09/26/17 9'-3"7'-10" 18° 3' FIRE SETBACK MIN 2X6 @ 24 O.C. 2X6 PURLING; SUPPORTS @ 6' O.C. 8' 10'-9" 3' FIRE SETBACK MIN 18° 2X6 @ 24 O.C. 2X6 PURLING; SUPPORTS @ 6' O.C. ARRAY DETAILS Scale: NTS MP3 SECTIONB 4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILPV06JOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- Scale: NTS MP2 SECTIONA Abby Ayende 09/26/17 LABELS REQ. BY NEC 690.17 APPLY TO: DISCONNECTS PV LOAD CENTERS COMBINER BOXES 1 PHOTOVOLTAIC POWER SOURCE REQ. BY NEC 690.31 (E)(3) APPLY TO: EXPOSED RACEWAYS, CABLE TRAYS COVERS OR ENCLOSURES OF JUNCTION BOXES 11 THIS ELECTRIC SERVICE IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM REQ. BY NEC 705.1 2(D)(4) APPLY TO: MAIN SERVICE PANEL 8 WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE 690.64(B)(7)-705.12(D)(7) REQ. BY NEC 705.12 (D)(7) APPLY TO: PV SYSTEM BREAKER 6 SOLAR AC DISCONNECT REQ. BY 690.13 (B) APPLY TO: AC DISCONNECT 7 SOLAR DC DISCONNECT REQ. BY 690.13 (B) APPLY TO: DC DISCONNECT 10 WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED. NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED! 690.5(c) REQ. BY NEC 690.5 (C) APPLY TO: INVERTER 4 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - ____ AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS 690.15, 690.54 REQ. BY NEC 690.54 APPLY TO: PV SYSTEM DISCONNECT 5 PV SYSTEM DC DISCONNECT RATED MAX POWER POINT CURRENT - ____ ADC RATED MAX POWER POINT VOLTAGE - _____ VDC MAXIMUM SYSTEM VOLTAGE - _____ VDC SHORT CIRCUIT CURRENT - _____ ADC 690.14(C)(2), 690.15, 690.53 REQ. BY NEC 690.53 APPLY TO: INVERTER 3 WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THE SECOND POWER SOURCE IS LOCATED ON WALL NEXT TO SUBPANEL RATED AC OUTPUT CURRENT - ____ AMPS AC NOMINAL OPERATING VOLTAGE - 240 VOLTS 690.54 - 705.10 REQ. BY NEC 690.54 APPLY TO: MAIN SERVICE PANEL 2 WARNING: PHOTOVOLTAIC POWER SOURCE REQ. BY CRC R331.7 APPLY TO: MAIN SERVICE DISCONNECTS 9 SIGNAGE REQUIREMENTS: 1. RED BACKGROUND 2. WHITE LETTERING 3. MIN. 3/8" LETTER HEIGHT 4. ALL CAPITAL LETTERS 5. ARIAL OR SIMILAR FONT 6. WEATHER RESISTANT MATERIAL, PER UL 969 WARNING - ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 690.17 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN REQ. BY NEC 690.56(C) AND 690.12 APPLY TO: INVERTERS 9 LABELS4.55 kW DC PV SYSTEMPRABHAKAR MANNE RESIDENCE20833 HANFORD DRIVECUPERTINO, CA 95014408-839-4074 (14) PV MODULESPANASONIC VBHN325SA16PV INVERTERSOLAREDGE SE 3800 H-USEVEREST EVERFLASHEVEREST 48S RAILLBLSJOB #: 17031790DESIGN BY: RDELGADO DATE# REVISION 01/12/170 Original 3/24/17 A Plan Check #1 9/25/17 B Panel and Inverter change ----C --------D ---- Abby Ayende 09/26/17 Abby Ayende 09/26/17 Abby Ayende 09/26/17 Abby Ayende 09/26/17 Abby Ayende 09/26/17 Abby Ayende 09/26/17 Abby Ayende 09/26/17 MP3 MP2 00 0 INV AC PRABHAKAR MANNE 20833 HANFORD DRIVE 17031790 LAYOUT MAP - INSTALL CREW PAGE INVERTER SERIAL No.: ---------------------------------------------------------------------------------------------- Abby Ayende 09/26/17