14090193 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 20696 DUNBAR DR CONTRACTOR:SHARATH PERMIT NO: 14090193
KANUKUNTLA
OWNER'S NAME. SHARATH KANUKUNTLA 20969 DUNBAR DR DATE ISSUED:09/29/2014
OWNER'S PHONE: 4084253500 CUPERTINO,CA 95014 PHONE NO:
❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL E]
TO CLEAR CODE ENFORCEMENT CASE: INSTALL(N) EV
License Class Lie.# CHARGING STATION IN SIDE YARD AREA
Contractor Date
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$1000
1 have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
APN Number:32633037.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS F ALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may,accrue against said City in consequence of the Issu Date:
granting of this permit. Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section
9.18.
ROOFS:
Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
inspection.
OWNER-BUILDER DECLARATION
Signature of Applicant Date:
Thereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1,as owner of the property.or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,25533,and 25534. 1 will
I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance:as provided for by the Health&Safety Code, cti ns 25505,25533,and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this �y
permit is issued. Owner or authorized agent: l
1 certify that in the performance of the work for which this permit is issued,l shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,l CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that l have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18. ,
Signature Date i�
ALTERNATIVE ENERGY PERMIT APPLICATION 1
1
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
CUPERT{NO
(408)777-3228• FAX (408)777-3333• building(ckupertino.org
1 _ `
PROJECT ADDRESS ' A^^ a ^/ O�N-e APN# 3 C:>3�
O R NB.�MRE�5� N 1 L,� P NE O t1 +�' ��v E IL u g j C,
STREET-AD�C7►4F*S� J LC—'-Y� �JW•W YI V� CIT , STATE -per L..-y - CA ci'��(FAX i 7
C!ZT T f,1 Y I �"� PHQNE 1. �`2) +l.l
STREET App,r 'SJf �C. �/T T I v - ITY,SlTTAT , ZIP /� y FAX
O }o p l,'Yy✓1 �.YiYV lr• \r e.,l.�l,� �'h, . r ( 4 � � 1
OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT
CONTBA�CT,O'gRI�NAM LIC.,F,NS N ER LICENSE aTYPE BUS.LIC#
CO I�'1N Y` ��^`, � �O (/V��✓ t'
ST E ADDRES^^ `���� 0..� ITY,STCo TE ZIP S C 2 PHONE —
ARCHITECT/ENGINEERNAME ` LICENSE NUMBER BUS.LIC# C� l
COMPANY NAME E-MAIL FAX
STREET ADDRESS) CITY,STATE,ZIP PHONE
USE OF E JFD Or DUpleX ❑ MUIti-Family PROJECT IN WILDLAND PROJECT IN
STRUCTURE ❑ Commercial URBAN INTERFACE AREA ❑ Yes />9 NO FLOOD ZONE ❑ Yes /kNo
SOLAR PANELS ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER:
FOR.SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION:
DESCRIPTION OF WORK Cc,� 1 ,� J � c-
By my signature below,1 certify to each of the following: 1 am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating�ilding nstruction. I authorize representatives of Cupertino to enter the abwLe-i4ntified propefty�for inspection purposes.
Signature of Applicant/Agent: Date:
SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY
0 OVER-THE-COUNTER
w
E" D EXPRESS
x
w El STANDARD
x
U
.ad ❑ LARGE= _
❑ MAJOR
PVApp_201 I.doc revised 03/16/11
CITY OF CUPERTINO
FEE ESTIMATOR- BUILDING DIVISION
ADDRESS: 20696 DUNBAR DR DATE: 09/29/2014 REVIEWED BY: MELISSA
APN: 326 33 037 BP#: M0 3 `VALUATION: j$1,000
PERMIT TYPE: Building PermitPLAN CHECK TYPE: Alteration/ Repair
PRIMARY PENTAMATION
USE: SFD or Duplex PERMIT TYPE: SOLAR-RE
WORK To Clear Code Enforcement Case: INSTALL N EV CHARGING STATION IN SIDE YARD AREA
SCOPE
Lj -t_ Ll
NOTE: This estimate does not include fees due to other Departments(i.e. Planning,Public Works,Fire,Sanitary Sewer District,School
District,etc . Theseees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info.
FEE ITEMS (Eee Resolution 11-053 El'. 7%1/13/ FEE QTY/FEE MISC ITEMS
Plan Check Fee: $0.00 1 # Alternative Energy System
Suppl. PC Fee: E) Reg. ® OT 0.0 hrs $0.00 $109.00 ICHRGSTA EV Charging Station
PME Plan Check: $0.00
Permit Fee: $0.00
Suppl. Insp. Fee.-(j) Reg. 0 OT j 0.0 hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
0
Work Without Permit? (E) Yes 0 No $109.00 E)
Advanced Planning Fee: $0.00 Select a Non-Residential E)
Building or Structure 0
Strom Motion Fee: IBSEISMICR $0.50 Select an Administrative Item
Bldg_Stds Commission Fee: IBCBSC $1.00
SUBTOTALS: $110.50 $109.00 TOTAL FEE: $219.50
Revised: 08/20/2014
1
OWNER-BUILDER DISCLOSURE FORM
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
CUPERTINO (408)777-3228• FAX(408)777-3333- buildingacupertino.org
Dear Property Owner(s):
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at:
SITE ADDRESS APN 3 Z 6 BP# (��?i;
OW ER NAME OWNER ADDRESS I l
ry
DESCRIPTION OF WORK:
We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of
your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We
will not issue a building permit until you have read, initialed your understanding of each provision, signed, and
returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless
you, the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
(DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.)
)E: C 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner-
Builder"building permit that erroneously implies that the property owner is providing his or her own labor and material
personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by
an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not
provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my
insurance coverage for injuries to workers on my property.
��Ir 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for
the construction and are not hiring a licensed Contractor to assume this responsibility.
3. 1 understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may
protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her
name instead of my own.
i[C 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license
numbers on permits and contracts.
5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the
total value of my construction is at least five hundred dollars($500), including labor and materials, I may be
considered an "employer" under state and federal law.
�tJL6. I understand if I am considered an "employer" under state and federal law, I must register with the state and
federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to
unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject
me to serious financial risk.
`�LT I understand under California Contractors' State License Law, an Owner-Builder who builds single-family
residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by
licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work
is performed under contract with a licensed general building Contractor.
�8. 1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for
any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction
defects in the workmanship or materials.
GY welBuildelForn1 2010.doc revised 04114110
9. I understand I may obtain more information regarding my obligations as an "employer"from the Internal
evenue Service, the United States Small Business Administration, the California Department of Benefit Payments,
and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State
License Board (CSLB)at 1-800-321-CSLB(2752)or www.cslb.ca.gov for more information about licensed
contractors.
(� 10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I
am the party legally and financially responsible for proposed construction activity at the site address listed above.
11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide
by all applicable laws and requirements that govern Owner-Builders as well as employers.
ijq
12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the
information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If
you contract with someone who does not have a license, the Contractors' State License Board may be unable to
assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed
Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or
employee of that individual or firm is injured while working on your property, you may be held liable for damages. If
you obtain a permit as Owner-Builder and wish to hire Contractors, you will be responsible for verifying whether or not
those Contractors are properly licensed and the status of their workers' compensation insurance coverage.
CONSTRUCTION LENDING AGENCY
(DIRECTIONS:Please complete the following construction lending agency information.)
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued
(Sec 3097 Civ.)
Lender Name: Lender Address:
Before a building permit can be issued, this form must be completed and signed by the property owner and
returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license,
form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued
to verify the property owner's n ture.
Property Owner's Signature: t Date: 4<
---------------------------------------------------------------------------------------------------------------------------------------------
(NOTE: The following Authorization Form is required to be completed by the property owner only when designating an
agent of the property owner to apply for a construction permit for the Owner-Builder).
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby
authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an
Owner-Builder Permit for my project.
Scope of Construction Project(or Description of Work):
Project Location or Address:
Name of Authorized Agent: Tel No
Address of Authorized Agent:
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the
above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other
verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's
signature.
Property Owner's Signature: Date:
Owne7BuilderFo ml 2010.doc revised 04/14/10
r
Sheet Index
1...Title, Index,and EV Quipment Mounting Location slingsh
2...Load Calculations& EV Charger Circuit Schematic a.. )t .
3...General Notes
4...Level-2 Charger- Installation Mechanical Owen Your Energy-
5...Level-2 Charger- Data, UL NEC, NEMA OFFICE COPY
----------------------------------------------------------- Electric Vehicle Charger
Additional Installation manuals, other hardware references
and certifications available upon request Installation Perm It
Permit 2013 California Electrical code; Underwriters Laboratory(UL) listed
charging system. As Installation:
1.EV charging system information: Level 1 or 2, EVSE system with UL listedLorMr� *@ P Chip CUPERTINOnumber or other &M-206 610t 20 90216 Ty1031 dbf i W& C26
approved nationally recognized testing laboratory, in compliance with UL2202, "Standard Building Department
for Electric Vehicle (EV) Charging System Equipment". �A06",
"°
r �
2.Existing electrical service panel information at the residence. Include EVSE loadand circuit
size to determine if electric panel upgrade is required. Provide load calculations to R V,_E: 1jFFi FOR CODE COMPLIANCE
determine if there is adequate capacity in the existing panel. (CEC220) 2013 Reviewed By:
3.Panel upgrade and electrical wiring shall be in conformance with the 2013 California P!,07' PLAN-9
Electrical Code. �:1BiE�CK�,
D 1f'';
COMMUNIITY DEVELOPMENT DEPARTMENT
/jaA� � 2�
BUILDING DIVISION-CUPERTINO //^
4.Identify if a second electric meter is required to be installed because of electricutility rate , p ( /
for EV charging. �;�PRC
This set of plans and specifications MUST be kept at the P 1vI�Y r DEPT
ob site duringconstruction. It is unlawful to rn •lce any '�— —
5.Clarify EVSE locations(garage, carport, interior,exterior, etc.) } changesor�Glter?tions on same,or to uev; ,Le DATE
therefrom,without approval from the Building Official.
6. EVSE shall be installed in accordance with manufacturer's guideline and must be suitable
The stamping of this plan and specifications SHALL NOT
for the environment(indoor/outdoor). If the EV charging equipment is located in an area r it or to be an a e violation
be held to permit
subject to physicalvehicular damage and adequate barrier shall be installed. 3to p or State Law. v r lly
1 P Y (i.e.C ) g q (i.e.C of any 'rb _
4" bollard) '
BY • C ,�VET
T�...
7.Submit installation guideline as part of submittal. PERMIT NO. ! / SEP 2 9 X014
X lay
Slingshot Power, Contractor
slingshiat
Equipment in this Electric Vehicle Charging System Title Sheet & Sheet Index
Date: 5-Sep-14 Project Details: Page Number:
p } g
164 Main St., Los Altos, CA 94022 Equipment Tuna ^anufacturers and Model Version: 1.0
Ph: 650308-9055 Scale: None Client: Sharath Kanukuntla
Fax: 650-887-0345 1 Level-2 Charger AeroVironment EVSE-RS Project: 408-425-3500 Address: 20696 Dunbar Way
California State Lic: B984488 Drawn: Tony Seng City: Cupertino,CA 95014
Standard Method Residential Service Calulation
1.0 General Lighting: 220.9Total
4300 Sq Ft. 12900 VA
Capacity 200 A
Small Appliance: 220.52(a) Main BTcakcr200 A
4 Circuits x 1500 VA 6000 VA
Laundry: 220.52(b) 1201240'VAC 1 PI 13W MAX
Circuits x 1500 VA 1500 VA
Minimuml0 AWG Cu'tNine Square D
Applying Demand Factors:Table 220.42 gated 75de%C)
1st 3000 VA x 100% 3000 VA L1, Ll
10 AWC Ground wire
Next 3000 VA x 35% 1050 VA ICA"under 1.5% I'taot drop
14400 Remaining VA x 25% 3600 VA t1L2N
TOTAL.................................................................. 7650 VA
2.0 Fixed Appliances: 220.53
It shall be permissible to apply a demand factor of 75%for four appliances other than u
eletric ranges,clothes dryers,space heating equip, air-conditioning equip.) u
YES/NO VA
Dishwasher YES 900 VA
Disposer YES 600 VA
Microwave YES 1125 VA G
Compactor NO 0 VA
Pool/Spa NO 0 VA
Attic Fan NO 0 VA u
Other 0 0 VA
TOTAL.................................................................. 1968.75 VA -
YES/NO VA (-V Charge'f
3.0 Eletric Dryer: (5000VA) 220.55,Table 220.54 Levet 2
A
5000 VA x 100% NO 0 VA
4.0 Cooking Equipment:Table 220.54
Oven 7200 VA x100% YES 7200 VA
Range 11000 VA x 100% NO 0 VA GEC
Col c kW Other o o VA CUPERTINO t,round
TOTAL.................................................................. 7200 8.0 :� a u di
i1 ing Depar-hent
5.0 Heating or A/C: 220.60(non-coicident loads) VA
l Q AC Load Center
Heating unit 1500 VA x 100% NO 0 VA ELECTRICAL LOAD TOTAL —�., `� a. 1 2 Pole 35 Amp
A/C Unit 6000 VA x 100% YES 6000 VA Service Total VA= 28218.75 F_i'lEVrE11 �.G 7 Circuit Breaker
Heating Pump 1500 VA 100% NO 0 VA VA/240= 117.58 Amps
'ODE COMPLIANCE.
(loads)............................Take Largest Load 6000
reviewed Sy:
6.0 Largest Motor 220.14(c) =430.24&440.6
0 VA 0 VA x 25% X
7.0 EV Charger Level 2 (5400)VA YES 5400 VA Slingshot Power, Contractor
Equipment in this Electric Vehicle
lingshak Char¢ine System Load Calculations & EV Charger Circuit Schematic
Date 5-Sep-14 Project Details: Page Number:
164 Main St., Los Altos, CA 94022 Equipment Type Manufacturers and Model Version: 1.0
Ph: 650-308-9055 Scale: None Client: Sharath Kanukuntla
Fax: 650-887-0345 1 Level-2 Charger AeroVironment EVSE-RS Project: 408-425-3500 Address: 20696 Dunbar Way 2
California State Lic: 6984488 Drawn: Tony Seng City: Cupertino, CA 95014
UNGROUNDED PANEL ❑
LEGEND POSITIVE GROUNDED PANEL ❑
NEGATIVE GROUNDED PANEL E
ABBREVIATIONS E) Utility Meter& MICROINVERTERS ❑
A...........Ampere
Warning Label
AC........Alternating Current
BLDG.. Building Structure Inverter W/Inte rated
CONC...Concrete. g THIS PROJECT SHALL COMPLY WITH:
DC.........Direct Current
DC DISCONNECT THE:
EGC.......Equipment Grounding Conductor 2013 CA BUILDING CODE
(E)..........Existing DC DISCONNECT& 2013 CA PLUMBING VODE
2013 CA RESIDENTIAL ODE
EMT.......Electrical Metal Tubing WARNING LABELS
GALV....Galvanized 2013 CA ENERGY CODE
GEC.......Grounding Electrode Conductor 2013 MECHANICAL CODE
GND.......Ground AC DISCONNECT& 2013 CA CITH/COUNTY FIRE CODE
HDG.......Hot Dipped Galvanized WARNING LABELS
I..............Current
aorn a Code of Reguladom
Imp.........Current At Maximum Power
Title 24, Pert 3
Ise...........Short Circuit Current JUNCTION BOX
kVA........Kilovolt Ampere Calrfamis Building SU-ndards Commission
kW..........Kilowatt Based on 2011 National EIttftal Code*
LBW.......Load Bearing Wall DC COMBINER BOX &
MIN........Minimum
WARNING LABELS
(N)..........Neutral
NEUT.....Neutral
NTS........Not To Scale tic
DISTRIBUTION PANEL
OC..........On Center &WARNING LABELS
PL...........Property Line
POI.........Point of Intersection
PV..........Photo Voltaic I— LOAD CENTER&
SCH........Schedule WARNING LABELS tECT11f8
SS...........Stainless Steel JANUARY 1.2014
STC........Standard Testing Conditionsatia�o�'�'�
TYP........Typical
2Pole......Grounding System(N) &GND DEDICATED PV
UPS........Uninterruptible Power Supply SYSTEM METER a CUPERTINO
UFER......Grounding system to foundation Building DepartMent
V.............Volt
CONDUIT RUN
Vmp........Voltage at Maximum Power ON EXTERIOR J
Voc.........Voltage at Open Circuit
W............Watt ,ED FOR CURE
3R...........NEMA 3R,Raintight COMPLIAWC(
CONDUIT RUN viewed By: ---_-__
X
Slingshot Power,Contractor
Equipment in this Electric Vehicle General Notes
slingshat. Charging System
Date 5-Sep-14 Protect Details: Page Number:
164 Main St., Los Altos, CA 94022 Equipment Type Manufacturers and Model Version: 1.0
Ph: 650-308-9055 Scale: None Client: Sharath Kanukuntla
Fax: 650-887-0345 1 Level-2 Charger AeroVironment EVSE-RS Project: 408-425-3500 Address: 20696 Dunbar Way 3
California State Lic: B984488 Drawn: Tony Seng City: Cupertino, CA 95014
IFI ATuf" R-Owrf a WIll witnin imp Dock CORPOWE H EADQUARTE R&
PiAur.iIMrnnriwrlm d isibribLAimm •tW-a1pp%r. •t3-l4 hwmWiFunmwnt Inc-
&I-f"
nc.drtn meran n a.am Jvf 0" , �� Wmd l!rt ud EV Baia go roalM
• AtrAri,ram-aith NtAIWLrrw Aft 000 rm.Vh;rr
iris-JAlaiLi Cal 1$7 W.HluntirngtoniDrive.;Buite202
• lr;b�rot bkt VQ"ago Morrow in. CA 91019
• t�krclwrwrrJcawn lstxxotn�TSt7t11fw1•rrl
9
• atMAUMM L Iz%7%.ablw { ri'�� ewpormte p.IvAi e:628-357-OM3
■ optIonsipe-ime+tat mourncontgurwoons ew 886$33.7148
• hllacwcwtcanmrunlotlunopdans (DwISE-A3-► f
'i � O k'i'�Ja 1l i't<f,cDhA
84MICE 04 CI I"ITALLATKIN www air k-L.GUlR ftIYS WuLi u113,
^t F
• F-.pand r'aq-duocJrl!aP 1r+drviarwc6nt � J�
ie�iF,�i�ni�.I.re.m•;�+41 R�4f�iti.�Nr+!` r
Ou-intrnlmR'-•.tunrunt--iur rm�tesdr1wants driE1 Irr�tJl tilGl r.717
Eltzttlnaa nttFw l wxvl r_��rrtl RaltsuLr�PgtcnctwnA�tl{7e
Tric EvSE-ft's Chnrgr r0 St an rhorgl_t.l1 SAE .,1772 ccftollanl
si;II..let-i%J6HOiJIL4tt 1110l.e.tlIt. i`0111JOUVttili..l011114,!n1lylxtid
In�tiCV'_Lrw,od•li Iwrtl-acurry•nIorietr AdwKari tpgem+,awt,arurkfliazr.
rnnrdnrrdrr�tvt nr,�rTmn^• nr rni�Il rJrr'.tn�tMwrtura-f'lwa 1-latirrta
=PffrrCJR4GA-n O9@ &,,Mr�Rs Lhasgenia' atlonsai-wlysr.=yet iably'lebMrs AL.POra%tothR
� �!tra• �s�-5 ri 72r:or'vl� .al;cic:'a--nLw_3racr,..,au",Kia-041 Ines inia sei nr.NMAJ-== .
ZM:lr E in 24%AC enclosure fry Indoor ainn airickiot tns3la^-¢ans.
qp,t tri
6"Frith T1iu E►1'�+6aji q lnll.l' LrJn Lru In w1vi N ally ul wuv 1r,Uwpulwr
1-+u .,r C L!rurvf 74+1 rraaA
t rrt rl,t0 1{+'-1 Ie d{*ler.Z..!..sr.+,,,.l++a F.tJ 4 6rC e5ctt'-+bey t6r.rr.••". ..
1-mt,Lahtirit awk rrQXI
&nd in-oewcta}n.and mtoe Op 1 nfa"t*r+ab gut E 15 E-R;i use to the
Cpa-whngTam^ec+s:an -2rrEo 12rr 4 ,Sri L,$,ikA J 4 avmlw.b w vi imUv V fTy Mi L':,
--ltT+L W]U-L a 4)lu ti r•uaR rie erg r adtl•Kp
.LID'{ICl4A'C
rw+KcinCk neIrtp C U PE R TI N O
171 -t 3.:,r.y 12'.% , `9UIldin4 L)epci fJi C�fli
w4Gt:c-Lt `4 bb(rrxl.c•btsa ��, �"'� 2
Lfl-`_to-ta�th lJ,p cc5'a.:w I�°_-llc
r ,rur<l.tr'. KEIJ,9 7!1 l^C
I:rtpl.t+rt�y C:r' yxp'd'�r.r 1X ILIK, i I 'i 1 tr1 E 0 PeVle�1✓I V�I��� FOR
CODE CdrY17-�.{� I �r
.L
wed By: �—
:rir+•r--P ndar�Ycr r.tr•� --�hrt r.� '�rr�w�wafrvr-m n.a tl�r.t cwltir rii �_.__'_-'
rr`r�ri..l+dh ai�.rs�rnbrnrt�
X
Slingshot Power,Contractor
Equipment in this Electric Vehicle
slingshc;>t Charging System Level-2 Charger Installation Note - Mechanical
Date: 5-Sep-14 Project Details: Page Number:
164 Main St., Los Altos, CA 94022 Equipment Type,_- Manufacturers and Model Version: 1.0
Ph: 650-308-9055 Scale: None Client: Sharath Kanukuntla /�
Fax: 650-887-0345 1 Level-2 Charger AeroVironment EVSE-RS Project: 408-425-3500 Address: 20696 Dunbar Way 4
California State Lic: 8984488 Drawn: Tony Seng City: Cupertino, CA 95014
.PECIFICATION
MOdar Ek$11E.AS
C'Or otor SAE J 1772 t;omt9 lark
Car cJ-ro rgl ng r uck ee-rmu nlc at6nn prahmc ul BAE J 177n C-CM l lord
UI-nrnelarns If' Fix 1d'VV x d' u apprxitnnabdy-
'4 Mage 2136-"?A 0'6A-A t W-ti1l-A:O rlitole-
4Dumbrrt autpwk prJvm r 20 Amp Miayrnurm
- CritbrdAker F,850� #Dr4rirp. NC7T u 9 Cri��.A -i4 Lit blvNkerWRh tht E:Vbh.H15Uharjm Dock,
Fr-Qgr!a+rgy 60HAr
Fc-Acr drown On IQ1C I_=ICICI n u woa•haur 5
Cale Ir.nglh Is ft-JA.157 M)
40p-timneil nabla fsnpth Up kr}= ft (I G r n)
Weight Y%Id-1 1*I'c C-Mb le t4.112 Iba la..315 kgY
Weight lylth 25 ft.mah4e -7.5 his 0.94 kg)
T4rr5p�rlilur' �Wrdki-� -22"F 10 +172'FC.301-2 b6 W't:]
`torr�.raralur 0-01L_.111%#8,rimanlriI tillu -io-r tv wr r-4ovo to-ruo"o3
Hu midity Up la 9D% nan•c�arrdaming: Rcliablr_prove n 1,ama charging Q + NO
Erwlrannwrlta I rartin p NEMA Typo 3 ariclaoura-raln44t wl h mountlnp plan Choice of major amwmakers N ;
Fie-pWtory compiftnr-a Ul-.FGG part ig vuapofB SofwLy lisLntg Lry UrmJer wriLery LaLxnat.ury (UL) a
4pwrilirar evsc a rn arrt+lrr t to rhunQr hart rrnlrrr Works with all naw Plug In EV% (SAE J.177'2 Cornpli�n� a► i •
f
Anti-theft assurance(permanent wird ng)'"r R •
1-year warr anty(parts& Is bar) a a a
3-y*ar on-site warranty with AV installation • • •
Outc:ior cl7ar9ing appfco edb-y ULINEC a •
Fw^r ft'oy VAIN a rti61MD •
Ea sy 3-step i nstallation 46
Easily moveable to an other location .
Add iti on al moU nti nq brackets,for second resi derlrce(opti ona 1)
SINAI-t11-1 Cone ctji-In-iec-tivity .:.. f3lrilCUPERT(I�p
Cally dj%eeeirnrnrinirafinn avail�hla � ,
�i J•., Wft-...c,,....e, - r1g [NO
2
REVIEWED FOR CODE
COMPLIANCE
Reviewed By
X
Slingshot Power,Contractor
lingshat.
Equipment in this Electric Vehicle level-2 Charger Datasheet & Information
CharQine System
Date: 5-Sep-14 Project Details: Page Number:
164 Main St., Los Altos, CA 94022 fouipment Type Manufacturers and Model Version: 1.0
Ph:650-308-9055 Scale: None Client: Sharath Kanukuntla
Fax: 650-887-0345 1 Level-2 Charger AeroVironment EVSE-RS Project: 408-425-3500 Address: 20696 Dunbar Way r r
California State Lic: B984488 Drawn: Tony Seng City: Cupertino, CA 95014
I