Loading...
14100061 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21867 GRANADA AVE CONTRACTOR:SOLARCITY PERMIT NO: 14100061 OWNER'S NAME: . SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL. COMMERCIAL. E] INSTALL 19 FLUSH MOUNTED,ROOF TOP PV PANELS cense Class 00, 40 ' # fa__ (4.94KW).INSTALL(N) 125AMP SUB PANEL Contractor ' Date le-) 1114 At4 I hereby affir t I am licensed under the provisions of Chapter 9 (commencing th Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the l[ performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$10000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35716133.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.1 agree to comply with all city and county ordinances and state Taws relating WITHIN ISS DAYS PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to saveIg M L CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may ae ue against said City in consequence of the granting of this permit. Additio ly,t e applicant understands and will comply Date: �V C with all non-point source regul ions r the Cupertino Municipal Code,Sect 9.18. P�= RE-ROOFS: Signature Date_. _(_ All roofs shall be inspected prior to any rooting material being installed. if a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. l will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay AreeAir Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupert'/o Mun' ipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 2550 ,25533 nd 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: permit is issued. 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,[ CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.l 8. Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION ` AE 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 \` CUPERTINO (408)777-3228•FAX(408)777-3333•building(c)cuperino.org \ PROJECT ADDRESS 21867 G RANADA AVE, APN# 3 OWNERN. CA,95014 FAX CONTACT NAME Marjan Javanmard PHONE 650.477.643 7E-MAILmjavanmard@solarclty.com STREETADDRESs391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR N CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAMESoIarCity Corporation LICENSE NUMBER 888104 LICENSE TYPE C10 BUS.LIC"28840 COMPANY NAMESoIarCity Corporation E-MAILmjavanmard@solarcity.com FAX STREETADDRESS391 Foster City Blvd CITY,STATE,ZIP Foster City, CA 94404 PHONE 650.477.6430 ARCHITECT/ENGINEER NAME FLICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ YeS ❑ NO ❑SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER. FOR.SOLAR PANELS: NUMBER OF PANELS/UNITS KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION:10,000.00 DESCRIPTION OF WORK Installation (19) rooftop flush mounted solar panel (4.94) kW `f` 10. 5 Arn . &k6 PLne- 1 efj By my signature below,I certify to each of the following: �Ihave m the erty owner or authorized agent to a e pro e s behalf. I have read this application and the information I have provided is correct. red the cription of Work and veri It is accurat . agree to comply with all applicable local ordinances and state laws relating to building construction. uthor' e e entatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: to/ SUPPLEMENT�l RMATION REQUIRED OFFICE USE ONLY .NFOpWp ❑ OVER-THE-COUNTER F ❑ EXPRESS x ❑ STANDARD U a ❑ LARGE a ❑ MAJOR PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 21867 GRANADA AVE DATE: 10/10/2014 REVIEWED BY: MELISSA APN: 357 16 133 BP#: D `VALUATION: j$10,000 `PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RE USE: PERMIT TYPE: WORK INSTALL 19 FLUSH MOUNTED ROOF TOP PV PANELS (4.94kW). INSTALL N 125AMP SUB SCOPE PANEL Elec. Plan Check 0.0 1 hrs $0.00 Elec.Permit Fee: IEPERMIT Other Elec. Insp. 0.0 hrs $48.00 NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District, etc. . Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Tee Resolution 11-0.5.3 Eff. 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: Q Reg. 0 OT 0.0 1 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 125 amps Electrical Permit Fee: $0.00 $48.00 IBELEC200 Services Suppl. Insp. Fee:) Reg. Q OT T0.0Thrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $48.00 Administrative Fee: 1ADMIN $45.00 Work Without Permit? 0 Yes 0 No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel Documentation Fee: ITRA VDOC $48.00 Building or Structure 0 i Strom Motion Fee: IBSEISMICR $1.30 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $143.30 $284.00 TOTALFEE- F $427.30 Revised: 08/20/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. A�jg BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONICCONCRETE 3. A NATIONALLY-RECOGNIZED TESTING 00 1=so 'D DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING l EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, DA ^EPARTNIENT FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. l Yt' �� EUILI�Ii; .=� VISION - CUPERTINO GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE r/ APPROVED GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY10�TF. / �..�; ,t � ; ecificat�..�s '.'L.ST be kept at the Tr 5 S-HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. ���� cb s to �.,II'_ ;,ruction. It is u fel to make any I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL /'K0'* 1 Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97 250.92(B). crane �s ,,)r ,,t.� rations on san e, or to deviate Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER "n_refrom, w.,r', .r approv, from the Building Official. kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR - CUPER t INO --1e c+amPl,,:�c' ' . . 'an anti SPeci`,ca"ens he violation NOT artrne,1 ,�.,. n , of the violation kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC 13uilding DeP �e held to pt.- .it ��r ice or State Law. LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). cf .any pro s MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. c T 00� NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE CODE COMPLIANCE p ill # l OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. F F I C COPY PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRII LICENSE GENERAL NOTES . . � _ _ Cutsheets Attached C''�. CA 888104 1. ALL WORK TO BE DONE TO THE 2013 C-8 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. eft' 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Cupertino REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: Pacific Gas and Electric Company x Y Y CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9 5 0 3 8 4 4 00 PREMISE OWNER: DESMPTION: DESIGN: BENEFIT O SHALL NOT 8E USED FOR THE WONG, JASON WONG RESIDENCE Sergio Cuadros'�f . SolarCity. NOR SH OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: NOR SHALL IT 8E DISCLOSED IN WHOLE OR IN Com Mount Type C 21867 GRANADA AVE 4.94 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENTS MODULES C U P E R TI N 0 CA 95014 3055 aewler Way ORGANIZATION, EXCEPT IN CONNECTION NTH r THE SALE AND USE OF THE RESPECTIVE (19) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN om PAGE N ' WWET: REV: DATE: Son T:(650)636 1 to C( INVERTER: 650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVI-4.2-OUTD-S-US-Z-A (408) 239-3876 COVER SHEET PV 1 10/7/2014 (686)—SOL-CITY(765-2489)www.solorcity.com PITCH: 18 ARRAY PITCH:18 MPI AZIMUTH:270 ARRAY AZIMUTH: 270 MATERIAL:Comp Shingle STORY: 2 Stories 3' FSB PITCH: 18 ARRAY PITCH:18 MP2 AZIMUTH:90 ARRAY AZIMUTH:90 1 MATERIAL:Comp Shingle STORY: 2 Stories �I W II `- 3'FSB 0 dlI, CUPERTINO Iquilding QePa went 4. A IEVVFi_) r()� 1 Cor)6 COMF)LIANGF m Keviewed By. NI - M I 3 Un-Locked L o e O (E) UTILITY METER & WARNING LABEL 3' FSB INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS I� © DC DISCONNECT & WARNING LABELS _ JM 3' FSB Ac AC DISCONNECT & WARNING LABELS Front Of House O DC JUNCTION/COMBINER BOX & LABELS �D DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS — CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR Inv c LC O — GATE/FENCE R (E)DRIVEWAY O HEAT PRODUCING VENTS ARE RED 21867 Granada Ave L_"J INTERIOR EQUIPMENT IS DASHED SITE PLAN N TOTAL ARRAY AREA (SF): 344 Scale:i/16" = i' TOTAL ROOF AREA (SF): 1027 w E TOTAL ARRAY AREA IS a33-54 01' 16' 32' PERCENT OF TOTAL ROOF AREA s CONFIDENTIAL- THE INFORMATION HEREIN [INVBTER* PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THEJ B-9503844 �� WONG, JASON WONG RESIDENCE Sergio Cuadros SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., M: -, NOR SHALL IT BE DISCLOSED IN WHOLE OR INunt Type C 21867 GRANADA AVE 4.94 KW PV ARRAY PART IZ OTHERS OUTSIDE THE RECIPIENT'S C U P E R TI N 0, C A 95014 3os5 a Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE # REC260PEZ - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHS' � DATE: Sm T:(650)638-1028 FA 94402 638-1029 PERMISSION of soLARCITY INC. VI-4.2-OUTD-S-US-Z-A (408) 239-3876 SITE PLAN PV 2 10/7/2014 (668)-soL-CITY(765-2489)www.solarcity.com S1 S1 AI 4°° ! w SUP 4 ER`T' �' uildi ` ��( —2 8'—1 —2 8 —1 ` 1 ng Den (E) LBW (E) LBW Revi� �D A.0 SIDE VIEW OF MP1 NTS SIDE VIEW OF MPZeViey( ` °f"'���q.,,�, A B MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 6411 2411 LANDSCAPE 6411 24" PORTRAIT 64" 20" PORTRAIT 64" 20" RAFTER 2X8 @ 16" OC ROOF AZI 2 70 PITCH 18 ARRAY AZI 270 PITCH 18 STORIES: 2 RAFTER 2X8 @ 16" OC ROOF AZI 90 PITCH 18 STORIES: 2 ARRAY AZI 90 PITCH 18 C.J. 2X4 @16" OC Comp Shingle C.J. 2X4 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4) PLACE MOUNT. (1) (E) ROOF DECKING (2) T(5) —INSTALL AG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER G(6) BOLT & WASHERS. (2-1/2- EMBED, MIN) (E) RAFTER 1 STANDO�� CCNFIDENTIAL— THE INFORMATICN HEREIN JOB NUMBER: JB-9503844 00 PREMISE OWNER DESCRIPTION: DESIGN:- CONTAINED ESIGN:CONTAINED SHALL NOT BE USED FOR THE WONG, JASON WONG RESIDENCE Sergio CuadrosBEN /f �1;SolarCity. NOR FITSH OF ANYONE EXCEPT SOLWHOLE INC., MOUNTING SYSTEM: _/ ��a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 21867 GRANADA AVE 4.94 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: C U P E R TI N 0, CA 95014 3055 aean;a way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (19) REC # REC260PEZ PAGE NAME: SHEET. REV: DATE San Mateo, CA 84402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN! INVERTER: T:(650) 638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-4.2—OUTD—S—US—Z—A (408) 239-3876 STRUCTURAL VIEWS PV 3 10/7/2014 (888)—SOL-CITY(765-2489)www.�oraty.com UPLIFT CALCULATIONS 10.07. 014 '\,,So�arCity. Slee lmount`r"r PV System #39.1 Structural Desian Software II CUPER r rry 0 yid g �, RM mow ; . epa En _sRoof _ C TRoofplod Slope lam 2 18° PV Module 0dentWon and Portrait �5;. ._B. C��✓1 P� nl PV Module Wla 39" Hardware) Com Mount T 6Y+ourld Snow po DA Teale 7-1 RodSh M OM PV Modules GApd i ASCE ft 7.4-1 wind OeefGAde Asci 7-10 MWS. l3eatc VNrtd ? V_ 110 mph 26 5 1A Gable ROOF Po 30.4-2ANC-WB MMIh : �: E fedive Mind 1 Module A us sf IBC 1909.7.1 Wind Pressure Expowre - 0.95 Table 30.3-1 f IA: a : Wind Diroctionallty Factor Rd_ 0^85 Section 26.6-1 VekKRV Pressure 4b 4h=0.00 (Kz)(Kzt)M(V^2) Eqndm ao.3-1 24.9 od -0.88 ft aaA zvB OWS Mand Press" p=gb G I lEg"MAIL wpm Dom X Y - uowta k Stendoif Spacln6 tarlds caps 64' 3v lit$l2e ► Not _Tim -pv Dead Load MI-PV 3 psf -^ Ht of Standoff T--Diuw Molbs Max AWN"Standoff Spadnpor6aR _ W foot pv Asgem" Did Load W-W 3 psf U QF Standoff T-anew 5QD bs CWDENTIAI- THE wFawATION HEMN N JB-9503844 0-0 PRS o� STC o� O MMED SNALL NOT BE USED FOR INE AWSolarGtv. BENEFlT OF ANYONE EXCEPT SOLAARCITY wc.. MouNTwc srsmt NlONG, JASON 1AIONG RESIDENCE r._--- .Sergio Cuadros N�SHALLR "+"" w Com Mount Type C 21867 GRANADA AVE 4.94 KW PV ARRAY PART PART TO OTHERS OUTSIDE THE RECIPIENTS OROAJ IZATION, EXCEPT w CONNECTION WITH Moouls: C U P E R TI N 0, C A 9 5014 THE sALE AND USE OF THE RESPEcn� 19 REC # REC260PEZ =5 0wrAw Way SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN PAGE NATE SLEET REY. DAIS T:(050)8Ja-1028 CA ( -�arze �MSSION OF 9aA:aTY W- ABBPVI-4.2-OUT0-S-US-Z-A (408) 239-3876 UPLIFT CALCULATIONS PV 4 10/7/2014 (mT(soL-=pes-2+es)eso)...oae. xoor, GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number. Inv 1: DC UngroundedINV 1 —(1)ABB CA # 888104 PVI-4.2-OUTD-S-US-Z-A —(19)REC � REC260PEZ AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006677717 AFCI Inverter; Zigbee 420OW, 277V/24OV/208V, 96%/96%/96% PV odule; 260W, 234.3W PTC, MC4, 40mm, Black Frame, ZEP Enabled C-10 Underground Service Entrance INV 2 Voc: 37.8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 125A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) SolarCity BRYANT Inverter 1 IND 6 (N) 125A Load Center 5 ABB 4 A 1 DC- Vstart= DEFAULT PVI-4.2-OUTD-S-US-Z-A Dc MP 2: 1x8 (E) LOADS B 25A/2P zaov r--------- ------------ -------- -- —E -----------------� Ll t2I DC' I 40A/2P N DG I 3 2 GCI �. �, Vstart= DEFAULT ------------------ E --- --- GEC 111N as Dc MP 1: 1x11 13 TT AA II Z I GND __ EGC--- --------- ------------ E -----------------� j (1)Conduit Kit; 3/4' EMT N I I EGCIGEC Z Z 40A/2P � --- GEC PER 7- NO To 120/240V SINGLE PHASE UTILITY SERVICE ' TO (E) LOADS REVIEVVf O ReVr�yye C(J,'4ti%'!_Ip, IC°r I I � G try; Voc* = MAX VOC AT MIN TEMP I (2)Bumdy/BIT2/o R (1)CUTLER—HAMM I BR225 PV BACKFEED BREAKER e (1)Solarcity 4 STRING JUNCTION BOX Multi—Cable nector, 2 Port B Breaker, 25A/2P, 2 Spaces AC 2x2 SiR GS, UNFUSED, GROUNDED DC —(I)Ground Rod; 5/8' x 8% Copper —(1)CUTLER—HAMMER /BR240 Breaker, 4OA/2P, 2 Spaces —(1)BLoYANT add C�tBer,R81251A2, 120/24OV, NEMA 3R ©� 1 AWG 18, THWN—Z, Black —(l)AWG /8, THWN—Z Red (WERE) ' 1 AWG 110, THWN-2 Black 1 AWG 110, 1NNN-2, Black Voc* =45285VDC Isc =9.01 ADC (2)AWG 110, PV N1RE Black Voc* =329.34VDC Isc =9.01 ADC (1)AWG 18, THWN-2, Red —(1)Conduit Kit; 3/4' EMT O 14F (1)AWG 110, THWN-2, Red O (1)AWG 110, THWN-2, Red Vmp =337.7 VDC Imp=8.5 ADC O (1)AWG 110, Solid Bare Copper EGC Vmp =245.6 VDC Imp=8.5 ADC LLL (1)AWG /8, THWN-2, White Neutral Vmp =240 VAC Imp=N/A AAC L (11)AWG 110, THWTI-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC (1 AWG 110, THWN-2,.Green. . EGC. _ . . . . . . . . . . . . . . .-(1)AN /8,.THNN-2,.Green . . EGC. . , .-(1)AWG,/8,.THWN-2,.Black. . .(WFRL). . . . . . _ . .-(1)AWG /8,.THWN-2,.Green. . . EGC/GEC (1)Conduit.Kit;.3/4'.EIdT. . . , . . . . . . cn (1)AWG 110, THWN-2, Black Voc* =329.34VDC Isc =9.01 ADC W: (2 j AWG 110, PV WIRE Black Voc* =452-85VDC Isc —9.01 ADC ®�(i)ANG 110, THWN-2, Red Vmp245.6 VDC Imp=8.5 ADC O�(1)AWG 110, Solid Bare Copper EGC Vmp =337.7 VDC Imp=8.5 ADC = P— (i)AWG 110, THWN-2, Green TGC CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB-9507-844 00 PREMISE ONNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE WONG, JASON WONG RESIDENCE Sergio Cuadros \SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSU: �r _/ �,c NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 21867 GRANADA AVE 4.94 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES CUPERTINO CA 95014 '/� ORGANIZATION, EXCEPT IN CONNECTION WITH , 55 gea30rvieI THE SALE AND USE OF THE RESPECTIVE (19) REC # REC260PEZ PAGE NAYS SHEET: REv DAIS s30 Mateo, CA iew Way 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-4.2-OUTD-S-US-Z-A (408) 239-3876 THREE LINE DIAGRAM PV 5 10/7/2014 (880)-SOL—CITY(765-2489). .s°larcilyorn abel Location: Label Location: Label Location'. WARNING:PHOTOVOLTAIC POWER SOURCE _ WARNING ' Code: PV SYSTEM Per •• DISCONNECT FOR CRC R331.2ELECTRIC SHOCK HAZARD Per . UTILITY OPERATION THE DC CONDUCTORS OF THIS CEC • Label Location: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN PHOTOVOLTAIC DC UNGROUNDED ANDINVERTERIS DISCONNECTPer Code: MAY BE ENERGIZED UNGROUNDED CEC .•0 .14.C.2 Labell-ocation: WARNING ' Per ..- ELECTRIC SHOCK HAZARD Label • • CEC •.� DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_APer Code: LOAD SIDCEC ES MAY BE ENERGIZED MAXIMUM POWER- • 53 IN THE OPEN POSITION POINT VOLTAGE(Vmp)_V MAXIMUM SYSTEM_V VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Isc) A .•- • WARNING '' Per ..- CEC 705.12.D.7 INVERTER OUTPUT CONNECTION .•- • • DO NOT RELOCATE WARNING Per THIS OVERCURRENT DEVICE ••- ELECTRICALSHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITIONLabel L• • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTIONPer Code: SOLAR MODULES ARE WARNING:ELECTRIC SHOCK 690.54; 690.17 EXPOSED TO SUNLIGHT HAZARD. DO NOT TOUCH Vw Fe TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICECOMPLIANCF Label • • DE-ENERGIZE BOTH SOURCE WARNING AND MAIN BREAKER. _ Code: PV POWER SOURCE MAXIMUM AC ELECTRIC SHOCK HAZARD 690.5(C) A IF A GROUND FAULT IS INDICATED OPERATING CURRENT NORMALLY GROUNDED MAXIMUM AC CONDUCTORS MAY BE OPERATING VOLTAGE V UNGROUNDED AND ENERGIZED .•- • • Label; Location:. CAUTION 'Code: Disconnect PHOTOVOLTAIC AC (POI) PHOTOVOLTAIC SYSTEM 690.64.13.4 DISCONNECTCode: CIRCUIT IS BACKFED Conduit CEC •.014.C.2 (CB): Combiner :. Disconnect(D)-. Distribution Panel Conduit(IC): Interior Run Label Location: MAXIMUh4AC _ q • CAUTION • Center OPERATING CURRENTPer 't' Code: DUAL POWER SOURCECode: (M): Utility Meter MAXIMUMACCEC 690.54CEC 705.12.D.7 OPERATING VOLTAGE _ V PHOTOVOLTAIC SYSTEM •I): Point of • • SC CA Label Set • 1 SolarCity SleekMountTM - Comp SolarCity SleekMountT"" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed r- Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and ® Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition of array trim and a lower profile all contribute • Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system. SleekMount as"Grounding and Bonding System" ® Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and EFL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device ® Place Comp Mount centered Zep Solar standoffs, effectively eliminating the - need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition ® Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw ® Place module Components ® 5/16"Machine Screw ® Leveling Foot Lag Screw Comp Mount ! CvP�a� B l INO � Comp Mount Flashing C � Ui��'� ':y .f> `` Ent RSV! EVVE3 0 0® R ► ,r ' a��O,G � � SolarCityo January 2013LISTED "4S olarCity January 2013�' O Solar inverters Additional highlights: – RS-485 communication interface (for connection to laptop or data i logger). i – Integrated Arc Fault Detection and y , ; Interruption(-A Version). Y - 4 v Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US A9111 Mechanical specifications _31000now— M, i 330 Nominal output power 300OW 360OW wo 380OW 4200W ........................................................................................................ .....i.......... i 3000 33001 . 33001 ."3600 4060' . 400b' 3300 42bo' 420Oi "4200". 46OOi . 4600{ Maximum output power wattage w w W W W W W W W W W W Ra.................................................................................................... 208V...;...240V._.......77V.......2.....V.......24..V.......277V.......208V......240V.......277V...;....268V......240V...;....27N.... ted d C o a 2 08 0 08 Number of independent MPPT channels 2 2 2 2 .. .. ......... ... .. ..... .... .. .. ................ tw Maximum usable power for each channel.............i.....................2000W........................................._3000W..........................................3000W..........................._..........._3000W...................... Absolute maximum voltage(Vmax) 600V .... .. .......... ...... .. ....... ..... .... .. ..... ... ......................................... ...... ................. ..Start-up_voltage(Vstart)..........................................-..................._...................................................................................200V.�adj:.120.350 ..........................................................................._................ ... Full Power MPPT voltage ranee.................................................160-530V..................1....... 120-530V 140-530V 1 a0-530V .. .. Operating MPPT voltage range ... 0.7 x Vstart 580V(>=90V) Maidmum current(ldcmax)for bothTvI p in 20A 32A 2A aral el 3 I Maximum usable current per channel 10A 16A............_....... t6A................. ...............................................................I........ ....I... ........ Maximum short circuit current limit per 12.5A 20 OA 20 OA R . A: T h 8 rV cannel ..Number of wire landing terminals per channel...s.......................................................................................... 2.pairs............_................................ `rf ..... a e .. .. Ing D ry, rraws� Arraywain termination Terminal block,pressure clam ,AWG10-AWG . a.. Partrr1ei�t 4 • __710T t Sp it- to/ ia 1 plit- 1 1 / p ft- 1 10/ € pltt 1-/ Grid connection type C r ................................................ ............. . ............................!...._ZW......0/3W........2W.........._2VJ......i._0/3VJ........2!y.........._2W........0/3W........2.......t_. 3W........2�....._ 1 - 2ft- 244- 183- 211- 244- 183- 21'1 1244- I �¢ Adjustable voltage range(Vmin-Vmax) GAdri)dustable grid frequency range M228V264V1 ............................................................ ..,,.. V..".._ ..................... ..,C OvD - CO MPL�AH Cfie uency. 6dPz .. .. ... ... ... 3 .. Re Re-vie Maximum current(I—) 14.5 14.5 12:0 . 1 Y.2 16.0 : 16.0 . '16.0 16:0 . .......................................................................................................... A�.........Aaua.._ Awas.........A!..........has.._..._Aa�s....I..... ws.._.....Pb�s.........far..s.........�aaws.........Aws.........!�wa..... ��.. Power factor >0.995 ................................................_...........................................................i.................,.............................................................................................................................................................................................................................. Total harmonic distortion at rated power <2% ........................................................................................................................................................................................................................................................................ This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wirin termination a Terminal block,Pressure clamp,AWG10-AWG4 inverters complements the typical time power tracking and improved – Single phase and split phase output - Revarse polarity Protection....................._....................... Yes number of rooftopsolar panels energy harvestin rid connection. .................................................................................................................................................................................... P 9Y 9• 9 Over-voltage..Protection.type............................... Varistor,2 for each channel.......................................................................................,_ enabling home-owners to get the most The flat efficiency curve ensures high – Wide input range for increased PJ arra round fault detection Pre start-up Riso and Dynamic GFDI(requires floatingarrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. QuW protection. vices Anti-islanding protection Meets UL 1741/IEEE754. requirements of the property. a consistent and stable performance — The high speed and precise MPPT Over voltage protection type Vanstor 2 iL-_L,z%L,-.9) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating i 20A,,,,'20A_i 15A,,,° 25A„° 20A_ 20A,,,°;20A,,,° 20A, i 20A,,,, 25A_i 25A_ i 25A—, This inverter offers a dual input output power range. tracking and improved energy ciency —' r section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency ss:s%, 97% 97% 97% ..... ..... . ... .................................._ CEO efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6W_, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Sta — s um tion <8w mmurticatlon installations with two different installations with reduced string size. – Integrated DC disconnect switch User-Interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 incl VsiJ70o Data Lo er o t... oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Amblern air operating temperature range 13 F to T140°F with derating above 122T(60 C) e example:East and West) unit able to withstand the harshest Ambient etr storage temperature range 4o F to+17s°F(-40°C to+80°C) ........ The dual input sections with environmental conditions. Relative humidltX...............................................................................................................................................................0-100%RH condensing............................................................................................. Acoustic noise emission level <50 db e 1 m independentMPPT enable a more ......................................................................................................:.................................................................................................................(N................................................................................................................ Maxmum operating.altitutde w thout derating.......................................................................................................6560_n...(2000 m)...................................................................................................... optimal energy harvesting condition. �� 1.Capal*ty enabled at nominal AC voltage and with suttkiern[x power available. Power and productivity for a better world" 2 ABO Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-0UTD REE PEAK ENERGY ZINK fb n -_. I- 35 5 ' YVQ PROULU YEAR) AR POWE,` U,lt`f"UT WARRANTY' +47 IVRTYF t t � -i' All measurements in Inches 1REC2SSPEZ REC26OPEZ Nominal Power-P_(Wp) 255 260 265 Watt Class Sorting-(Wp) 15 15 t5 3'tr Nominal Power Voltage-V_(V) 30.5 30.7 30.9 =4 E0 Nominal Power Current-I_(A) 8.42 B.50 858 e b4elayb'- Open Circuit Voltage-V,(V) 37.6 37.8 38.1 r8tf Anodizi;4alum 11 Short Circuit Current-IX(A) B.95 9.01 9.DB Z.4pGrooveCiY Panel Efficiency(%) 15.5 15.8 16.1 •unC 4zarifez- W67rot®at 4tnn�svlarcab4e,47 4I The electrical characteristics are within /-10%of the indicated valuesof land P.at standard Test conditions(STC). --- Values at standard test conditions STC(airmass AM 1.5,Irradiance 1000 W/mV cell temperature 25'C). I At low Irradiance of 200 W/m'(AM 1.5 and cell temperature 25'C)at least 97%of the STC panel efficiency will be achieved. �II�I l fl I°II t. Nominal Power-Pt (Wp) 193 197 202 Nominal Power Voltage-V_(V) 2B.5 29.0 29.4 Nominal Power Current-I_(A) 6.77 6.81 6.90 v' +F`9 RTW Open Circuit Voltage-Va(V) 35.3 35.7 36.0 !'"C,.:F( Short Circuit Current-1.(A) 7,21 7.24 7.30 ding 0, Nominal op-ting-11 temperature NOCT(800 W/ms,AM 1.5,windspeed I m/s,ambient temperature 20°C). ( 7 I 10year product warranty. C OMPL)A.N C• COos 25 year linear power outputwarranty USTU (max.degression in performance of 0.7%p.a.). UL 1703.Fire rating Class C REC is a leading global provider of solar energy solutions. With more than 1S years of experience,we offer sustainable,high performing �\ ^ products,services and investments for the solar industry.Together with our partners,we create value by providing solutions that better R EC meet the world'sgrowing energy needs.REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Our 1,600 employees worldwide generated revenues of USD 647 million in 2013. www.rxgroup.com d SMOKE ! CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION CUPlEFumo 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 (408) 777 -3228 • FAX (408) 777 -3333 - buildina(a�cuoerting.orq Address 2- C�tiAPP, Ayz-. auncri o,, GAqs# PURPOSE This affidavit is a self - certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single - family and multi family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and /or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the Immediate vicinity of the bedroom( s X X On evea level of a dwelling unit Including basements X X Within each slee intr room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel- burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CSC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above - referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Building a-ad California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to cornoty with the terms rrtfa conditions of this statement Signature.................................... ............................... Uc.# ............ .......................... Date:................... Smake and CO form. doc revised 03118114 t.