13040124 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 11247 CATALINA CT CONTRACTOR:LORETTA Ll-SEVILLA PERMIT NO: 13040124
OWNER'S NAME: LORETTA Ll-SEVILLA 11247 CATALINA CT DATE ISSUED:04/16/2013
OWNER'S PHONE: 4083661870 CUPERTINO,CA 95014 PHONE NO:
❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL
License Class Lic.# INTERIOR REMODEL KITCHEN 250 SQ FT,BATHROOM
100
Contractor Date SQ FT
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
1 have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$60000
1 have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35621037.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
1 certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct.1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the ,/ ?
granting of this permit. Additionally,the applicant understands and will comply Issued by: / 115W QT��T Date: �GJ J
with all non-point source regulations per the Cupertino Municipal Code,Section
9.18.
RE-ROOFS:
Signature Date All roofs shall be inspected prior to any roofing material being installed.if a roof is
installed without first obtaining an inspection,1 agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date:
the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,255339 and 25534. 1 will
I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25,5",,25533,and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. 3
Owner or authorized agent: Date: ftll
I certify that in the performance of the work for which this permit is issued,I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,l CONSTRUCTION LENDING AGENCY
become subject to the Worker'sCompensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that I have read this application and state that the above information is
correct.I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18.
Signature DatePtd 2pl
-ao2 ll2 y 7 �'�%�-�ruv9
CONSTRUCTION PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 B(\
CUPERTiNO (408)777-3228•FAX(408)777-3333- building(d)cupertino.org 'JV
❑NEW CONSTRUCTION ❑ ADDITION ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMff#
PROJECT ADDRESS AIN# ��(,-, 2
OWNER NAME PHO �Y E-MAINt� J
U YID v;
STREET ADDRESS CITY,STATE,ZIP FAX
CONTACT NAME, PHONE E-MAIL
I _n
Ka*LIL L. __Se V i I
STREET ADDRESS CITY,STATE,ZIP 7
FAX
❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME LICENSE NUMBERLICENSE TYPE BUS.LIC#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
fy
ARCHITECT GINGER N E LICENSE NUMBER BUS.LIC#
1 (�
COMPANY NAMP i Le A,,` � E-MAIL FAX
'f\ J t e✓0 ao�. cam
STREET ADDRESS CITY,STATE ZIP PHONE
lU s L I`LL f S/30 j(p"CPc1-,Z
DESCRIPTION OF WORK
.rn+ r v kch n d , oo o n r r-
EXISTING USE PROPOSED USE CONSTR TYPE #STORIES USE TYPE OCC. SQ.FT. VALUATION($)
b ms's 1/3 vZ-
AREA NEW FLOOR DEMO TOTAL
AREA AREA AREA NET AREA
BATHROOM KrTCHEN OTHER
REMODEL AREA /jt� REMODELAREA�`g� REMODEL AREA
PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH
❑ATTACH
#DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY ❑YES
BEING ADDED? y'1'1l 0 ADDITION? -AO
PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF ISTHEBLDGAN El RECEIVED BY: TOTAL VALUATION:
PLANNING APPL#% 3WO PLANNING APPROVAL LETTER EICHLERHOME? �0 ��qq �p
�/ V0v
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information 1 have provided correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relating to buil struction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes.
Signature of Applicant/Agent: Date: &(. I
SUPPLEMENTAL INFORMATION REQUIRED PLAN CHECK TYPE ROUTING SLIP
_New SFD or Multifamily dwellings: Apply for demolition permit forOVER-THE-COUNTER BUILDING PLAN REVIEW
existing building(s). Demolition permit is required prior to issuance of building /1/
permit for new building. ❑ EXPRESS PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD /❑ PUBLIC WORKS
form if any Hazardous Materials are being used as part of this project.
❑ LARGE ❑ FIRE DEPT
_Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT
submittal of Building Permit application.
❑ ENVIRONMENTAL HEALTH
BldgApp_2011.doc revised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR-BUILDING DIVISION
ADDRESS: 11247 Catalina ct DATE: 04/16/2013 REVIEWED BY: Mendez
APN: BP#: 3� fa/oZ *VALUATION: $60,000
PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair
PRIMARY SFD or Duplex PENTAMATION 1 R3SFDREM
USE: PERMIT TYPE:
WORK interior remodel kitchen 250 sq ft bathroom 100 s ft
SCOPE
k
ieclf, Pk4re C`herA n:ii r. E.ncrcr. . 1'rrr r(h:clt
ET�31hrr.lierdi.lrsT <1,-c?•:L r '�ir ; Lr;,� lsi, _finsjl.
_tldth.Inf�. ffre� Phf„ah. Tr�;u. F,r: film.Gasf=.F <�:
NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School
District,eta). Thesefees are based on the prelimina information available and are on an estimate. Contact the De t or addn'l info,
FEE ITEMS (Fee Resolution 11-053 Eff.' 7i1/12� FEE QTY/FEE MISC ITEMS
Plan Check Fee: $0.00 100 I s.f. Remodel,Bath(<=300 sf)
Suppl. PC Fee: Reg. OT 0.0 hrs $0.00 $600.00 1REMRESBAT
PME Plan Check: $0.00 250 1 s.f Remodel,Kitchen(<=300 sf)
Permit Fee: $0.00 $600.00 1REMRESKIT
Suppl. Insp.Fee-0 Reg. Q OT 0,0 hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
Consif-iu•tion Tax:
,1(1/111 11istra/ive Fee:
Work Without Permit? 0 Yes Q) No $0.00
Advanced Planning-Fee. $0.00 Select a Non-Residential E)
71'avel Building or Structure 0
i
Strong Motion Fee: 1BSEISMICR $6.00 Select an Administrative Item
Bldg Stds Commission Fee: 1BCBSC $3.00
$9.00 $1,200.00 ` Tt)TAL FEE.° $1,209.00
Revised: 04/01/2013
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
CUPERTINO Fax: 408-777-3333
CONTRACTOR/ SUBCONTRACTOR LIST
JOB ADDRESS: / Z PERMIT# (? 0
OWNER'S NAME: L 0k0-r7W L j PHONE -; -- -
GENERAL CONTRACTOR: '208 6 V BUSINESS LICENSE#
ADDRESS: /S7D`/�- V (ten �&-w /'W CITY/ZIPCODE: ZA
*Our municipal code req res all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALLSUBCON RACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature Date
Please check applicable subcontractors and complete the following information:
SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE #
Cabinets & Millwork (3) 1
Cement Finishing
Electrical L
Excavation J 1
Fencing V VV
1 4A�-
Flooring/ Carpeting
Linoleum/Wood
Glass /Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting/Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
Owner/Contractor Signature Date
Building Department
City Of Cupertino
10300 Torre Avenue
Cupertino, CA 95014-3255
Telephone: 408-777-3228
C U P E RT I N O Fax: 408-777-3333
CONTRACTOR/ SUBCONTRACTOR LIST
JOB ADDRESS: ,.ef"7 yG/n/f} PERMIT#
OWNER'S NAME: Lace-4A L.i Skvk PHONE# U M ate 19 7 8
GENERAL CONTRACTOR: Fd,4p- SINESS LICENSE #
ADDRESS: CITY/ZIPCODE:
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE.
I am not using any subcontractors:
Signature Date
Please check applicable subcontractors and complete the following information:
V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing
Flooring/ Carpeting
Linoleum/Wood
Glass / Glazing
Heating
Insulation
Landscaping
Lathing
Masonry
Painting/Wallpaper
Paving
Plastering
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
Owner/Contractor Signature Date
r
OWNER-BUILDER DISCLOSURE FORM
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255
CUPERTINO (408)777-3228• FAX(408)777-3333•building(alcupertino.oro
Dear Property Owner(s):
An application for a building permit has been submitted in your name listing yourself as the builder of the property
improvements specified at:
SITE ADDRESS /� APN03-7 BP#
12,4'I �, i n lr0 5b- Z)OWNTR NAM i OWNER ADDRESS
L - 51 l a.,
DESCRIPTION OF.WORK:
r1krn0_1 remodOoi -4 2
We.are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of
your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We
will not issue a building permit until you have read, initialed your understanding of each provision,signed, and
returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless
you,the property owner, obtain the prior approval of the permitting authority.
OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION
(DIRECTIONS:Please read and initial each statement below to signify you understand or verify this information.)
I understand a frequent practice of unlicensed persons is to have the property owner obtain an"Owner
udder"building permit that erroneously implies that the property owner is providing his or her own labor and material
personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by
an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not
provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my
insurance coverage for injuries to workers on my property.
2. I understand building permits are not required to be signed by property owners unless they are responsible for
the construction and are not hiring a licensed Contractor to assume this responsibility.
,el' 3. 1 understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that.l may
protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her
name instead of my own.
1 understand Contractors are required by law to be licensed and bonded in California and to list their license
numbers on permits and contracts.
-%4:
5. 1 understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the
total value of my construction is at least five hundred dollars($500), including labor and materials, I may be
considered an "employer" under state and federal law.
L&. I understand if I am considered an "employer" under state and federal law, I must register with the state and
federal government, withhold payroll taxes, provide workers'compensation disability insurance, and contribute to
unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject
me to serious financial risk.
7. 1 understand under California Contractors'State License Law, an Owner-Builder who builds single-family
residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by
licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work
is performed under contract with a licensed general building Contractor.
� 8. 1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for
any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction
defects in the workmanship or materials.
OwnerBuilderFormz 2010.doc revised 04/14/10
.2 � 9. 1 understand I may obtain more information regarding my obligations as an"employer"from the Internal
Revenue Service, the United States Small Business Administration,the California Department of Benefit Payments,
and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State
License Board (CSLB) at 1-800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed
contractors,
XTi 10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I
am the party legally and financially responsible for proposed construction activity at the site address listed above.
��l1. 1 agree that,as the party legally and financially responsible for this proposed construction activity, I will abide
by all applicable laws and requirements that govern Owner-Builders as well as employers.
Y�12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the .
information I have provided on.this form. Licensed contractors are regulated by laws designed to protect the public. If
you contract with someone who does not have a license,the Contractors' State License Board may be unable to
assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed
Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or
employee of that individual or firm is injured while working on your property,you may be held liable for damages. If
you obtain a permit as Owner-Builder and wish to hire Contractors,you will be responsible for verifying whether or not
those Contractors are properly licensed and the status of their workers' compensation insurance coverage.
CONSTRUCTION LENDING AGENCY
(DIRECTIONS:Please complete the following construction lending agency information.)
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued
(Sec 3097 Civ.)
Lender Name: Lender Address:
Before a building permit can be issued,this form must be completed and signed by the property owner and
returned to the agency responsible for issuing the permit. Note:A copy of the property owners drivers license,
form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued
to verify the property owners sin ur
Property Owner's Signature: Date: &0I )(o 2_21
-
--------------------------------------------------------------------------------------------------------------------------------------------
(NOTE: The following Authorization Form is required to be completed by the property owner only when designating an
agent of the property owner to apply for a construction permit for the Owner-Builder).
AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF
Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby.
authorize the following person(s)to act as my agent(s)to apply for, sign, and file the documents necessary to obtain'an
Owner-Builder Permit for my project.
Scope of Construction Project(or Description of Work):
Project Location or Address: 0-41 CA+-a Ii,i a_ Cou..,�
Name of Authorized Agent: Tel No
Address of Authorized Agent:
I declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the ..
above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other
verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's
signature.
Property Owner's Signature: Date: ��r�1 `1�, Zo )3
OwnerBuilderForm 2010.doc revised 04/14/10
REVISIONS BY
Ll SEVILLA RESIDENCE
PRINTED ON
April 16, 2013
THE PLANS,IDEAS AND DESIGNS SHOWN
ON THESE DRAWINGS ARE THE PROPERTY
OF THE DESIGNER, DEVISED SOLEY FOR
THIS T. PLANS SHALL NOT S£
I,--,v,�r-•I��n �//-� � ^ IIS Jit,\�J�JI� USED,,WHOLE WHOLE OR IN PART,FOR ANY
OTHER PURPOSE WITHOUT THE WRITTEN
u V PERMISSION MICHELLE MINER DESIGN
ASSESSORS PARCEL # 350-21-037 I INDEX - VICINITY MAP - ANALYSIS SITE PLAN �
>ti
LOT AREA: 5,000 S.F. 2 EXISTING FLOOR PLANS CLO E
ZONING: 1`-1 (D
3 NEW FLOOR PLANS - INTERIOR ELEVATIONS Q �?
i U
TYPE OF CONSTRUCTION, V'�
EM ELECTRICAL PLAN � ctS Cz O
OCCUPANCY RATING- R-3, U - p u-
EXISTING USE: SINGLE FAMILY RES. +r �_
BUILT IN 19ro2 fC O
SLOPE OF LOT FLAT LOT CD
i EXISTING (D.07C) 00N
EXISTING LOUDER FLOOR: 1(050 S.F.
ami o
/ EXISTING UPPER FLOOR: 1150 S.F. CD
O �
/\
EXISTING GARAGE: 460 S.F. 13-
]ED00 00
C:)32SO S.F, CO
FO
AREA TO 5E REMODELED 350 S.F.
i
O BUILDING DiNASION -CUPERTINO y �
iz
This set of plans and specifications MUST r kept at the -}
I changes or alterations on same, or to deviate
therefrom without approval from the B i1
The Stamping of this plan and specifications SHALL.NOT TM Y
# - - -
- i of any provisions of any G' Ordinance or State Law.
NO ALTERATIONS OR
ADDITION TO THE EXTERIOR
DATE 5'• -3
1
GENERAL. NOTES:
SCOPE OF WORK
---------------------------------------------- ;
ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE REMODEL KITCHEN AND NOOK •` �.� o
OVER SCALED DIMENSIONS, ANY DISCREPANCIES REMODEL 2 BATHROOM ON LOWER FLOOR L
SHALL BE BROUGHT TO THE ATTENTION OF MICHELLE Q �_
MINER DESIGN PRIOR TO COMMENCING.
OFFIVE
L
VERIFY LOCATION OF UTILITIES AND EX15TING CONDITIONS <f COQ)
T 517E PRIOR TO CONSTRUCTION AND BIDDING. r
CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR METHOD Q,
AND MANNER OF CONSTRUCTION AND FOR ALL J05 517E NOTES ��✓✓ ( t
\ SAFETY DURING CONSTRUCTION. ® V
i 1. ALL CONSTRUCTION SHALL COMPLY WITH:
SLOPE ALL FINISH GRADES IN. 5io 5'-0" AWAY FROM
STRUCTURE FOR POSITIVE DRAINAGE w LANDSCAPED AREA 2010 CALIF. FIRE CODE ,
4 SLOPE GRADE 2% MIN. ,w PAVED AREAS. 2010 CALIF. BLDG CODE �J
\ _ _ 2010 CALIF. RESIDENTIAL GODS
y
a d
ALL WORK APPLIANCES AND EQUIPMENT SHALL COMPLY WITH " `ar
2010 CALIF. MECH. CODE Idinq I � '
G.E.G. TITLE 24 RESIDENTIAL ENERGY STANDARDS. ' ar_��eI"'
V 2010 CALIF. PLUMB'G CODE •—
NO CONSTRUCTION EQUIPMENT OR PRIVATE VEHICLES 2010 CALIF. ELEC. CODE 0 13s t�
llic;r, F
SHALL PARK OR BE STORED WITHIN THE DRIPLINE OF 2010 CALIF. ENERGY CODES ` ' f ' r' h ;{jl�
\ GtJrv; iA#
\ 1 ANY ORDINANCE PROTECTED TREES ON SITE, 2010 CALIF. GREEN BUILDING CODES Sv
ADDRESS NUMBERS ON BUILDING SHALL BE CLEARLY V1515LE ANY OTHER APPLICABLE LOCAL 'v
_ FROM STREET OR ROAD FRONTING THE PROPERTY. 6 STATE LAWS 4 REGULATIONS. �.
MIN. 4" HIGH X 1" WIDE PER CRC 8319. C �
A D
LL
CATALINA CT.
OWNERStaffordCr 1p
Poyeyg
ROLAND B LORETTA s
1,ia;"
LI SEV ILLA ' Bubb Rd Bubb Rd Bubb Rd
(408) 892-699(0 "
c`a n
11241 CATALINA GT, t r
CUPERTINO, CA 95014
DRAWN
Clarkston Avc to Jolla Ct n byp4
�a
DESIGNER: MM
N CHECKED
MICHELLE MINER DESIGN a - Catalina Ct MM
PLOT PLANS MICHELLE MINER - o-
, DATE
CHECKEDN� � N 18488 PROSPECT RD. #� saPja'so;oAaos Verdes Ct APRILIb2013
SARATOGA, GA 9500 B
SCALE
(408) 39(o-0984 4
;a � AS SHOWN
Vic: d JOB NO.
Suthertand Ave !4onierey Ct
LAt`JN IT.
TE �,, SHEET
DA
r ��
Id KaWPe40 > Redondo Ct
g 7yyg��! -prgs � � LPA
H O
U n
Wilkinson Ave 9 Terra Bella Cr
OF SHEETS
iS'd
16 I REVISIONS BY
I I
Fi
NOTF-S � I
I ,
I
THE CONTRACTOR AND/OR SUPPLIER OF MATERIALS SHALL NOT
1. I I
SCALE ANY DIMENSIONS FOR CONSTRUCTION PURPOSES, IN THE
EVENT A DIMENSION 15 REQUIRED THAT DOES NOT OCCUR ON I
THE DRAWINGS AND/OR A DIMEN51ON ERROR IS FOUND ON THE ----------------------- '----------"-----
DRAWINGS, THE CONTRACTOR AND/OR SUPPLIER OF MATERIALS April 16, 2013
I I PRINTED ON
WILL NOTIFY THE OFFICE OF MICHELLE MINER DESIGN, AND REQUIRES I { (
ASSISTANCE AS SOON AS 1=055I15LE, THE CONTRACTOR AND/OR
THE PLANS,IDEAS AND DESIGNS SHOWN
SUPPLIER OF MATERIALS SHALL BE SOLELY RESPONSIBLE FOR I I I
THE RESULTS OF ERRORS, DISCREPANCIES AND OMISSIONS WHICH I I I THE DESIGNER. DEVISED ON THESE DRAWINGS ARE THE PROPERTY
THE CONTRACTOR AND/OR MATERIAL SUPPLIER FAILED TO NOTIFY A THIS
NOT FOR
THE OFFICE OF MICHELLE MINER DESIGN. PRIOR TO CONSTRUCTION I ( THIS PROJECT. PLANS SHALL NOT SE
O FABRICATION OF THE WORK, NO DEVIATION FROM THE USED,WHOLE OR IN PART,FOR ANY
AND/ R I OTHER PURPOSE WITHOUT THE WRITTEN
PLANS IN ANY WAY SHALL BE MADE WITHOUT THE WRITTEN CONSENT { I PERMISSION MICHELLE MINER DESIGN
OF MICHELLE MINER DESIGN, APPROVAL BY THE CITY INSPECTOR DOES {
NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THE PLANS OR OTHER
DOCUMENTS PROVIDED BY THE OFFICE OF MICHELLE MINER DESIGN. I I I
CLO) E
2 SHOULD CONTRACTORS AT ANY TIME DISCOVER AN ERROR INA I I
5H TION
ATION OR DISCREPANCY OR VARIATION UPPER FLOOR � Q
DRAWING OR SPECIFIC HE SHALL REPORT I I
0
BETWEEN DIMEN81ONS OR OTHER INFORMATION, OVER THIS AREA Q
AT ONCE TO THE MICHELLE MINER DESIGN, FOR CLARIFICATION AND SHALL I I I U
NOT PROCEED WITH THE WORK
AFFECTED UNTIL CLARIFICATION HAS BEEN 0
MADE, IF WORK PROCEEDS WITHOUT NOTIFICATION, THE OWNER AND THE I V
N51BLE FOR THE CONSEQUENCES,
CONTRACTOR SHALL BE RE5P0 { � I �
DIMENSION FIGURED ON DRAWINGS
SHALL BE FOLLOWED IN EVERY
CASE IN PREFERENCE TO SCALED DIMENSIONS. IN GENERAL, DETAIL I N { i '�
I �
E 0
DRAWINGS TAKE PRECEDENCE OVER DRAWINGS OF SMALLER SCALE, I \ I — — — — — — — — —
(D (/) -
mewimmm
3, CONTRACTOR SHALL VERIFY ON-SITE ALL GRADES, EXISTING I I -
- — — — 1- — — — — — — — — — — — — — — — — — — — — — — — — — — � � c
PROPERTY LINES, EASEMENTS, SETBACKS, t0'-4" x 4'-0" I �
IMPROVEMENTS, PR I \ I
UTILITIES, AND 51.15-5TRUCTURE5, WHERE DISCREPANCIES OCCUR, 2 8 2'-6" x 6'-01'-O" x 6'-9 Z"3 I x d" 0
CONTACT MINER RESIDENTIAL, I
I \ O O O
4 THESE PLANS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY. O m m O =___= I CL
THEY AR ENOT EXHAUSTIVELY DETAILED NOR FULLY SPECIFIED, IT IS I \ I
\ H _
owl—
THE RESPONSIBILITY OF THE CONTRACTOR TO SELECT, VERIFY, AND
I 1 C0
AND RESOLVE AND INSTALL ALL THE MATERIALS AND EQUIPMENT. \ I I L
tV
\ III / / 00
I NO0<
QUALITY CONTROL Q \ ���I�� I � �
5. THE CONTRACTOR 15 SOLELY RESPONSIBLE FOR THE QUAL KITCP N I I I cA / I _ M Ict
-
00
AND CONSTRUCTION STANDARDS FOR THIS PROJECT, x -- -- i i"WON LOAD N BOO I i
\ II 4
VERIFY AND COORDINATE INSTALLATION Q \ J/1 I BEARING WALLS w I r
6, THE CONTRACTOR SHALL VER `� oil
OF SEWER, LATERAL GAS METER AND WITH APPLICABLE UTILITY I 1 {
COMPANY AND PUBLIC WORK DEPARTMENT AND BE IN CONFORMANCE
-----
I I`�
WITH LOCAL CODES AND ORDINANCES. I I I I
I
I I I
7, CONTRACTOR SHALL BE RESPONSIBLE AT HIS OWN EXPENSE FOR I
ANY DAMAGE TO PUBLIC OR ADJOINING PRIVATE PROPERTY DUE
TO H15 WORK,
I
5, CONTRACTOR SHALL PATCH AND REPAIR ALL DAMAGED SIDEWALKS I REMOVE CABINETS
AND CURBING PER LOCAL STANDARDS,
( I I
C3, PROVIDE EXPANSION AND CONTROL JOINTS IN ALL EXTERIOR CONCRETE I
BE PER INDUSTRY STAND ,
SLABS. SPACING SHALL ARDSI
10, RESPONSIBILITY: THE CONTRACTOR SHALL BE RESPONSIBLE WITH I Q p I {
THE COORDINATION OF THE ENTIRE WORK AND FOR THE COMPLIANCE `r ■ _ _ _x
—
WITH ALL CODES AND LAWS, HE SHALL ALSO BE RESPONSIBLE FOR I
:TEEING THAT ALL SUB-CONTRACTORS WORK CONFORM TO JOB ti)� O z GUE6T
.�.� •—
u z to
CONDITION, I I _
LIVING 5,4TH I
11, SLOPE ALL FINISH GRADES IN, 5io 5'-O" AWAY FROM LL �
STRUCTURE POSITIVE DRAINAGE w LANDSCAPED AREA I p { ROOM o — =
STRUCTURE FOR P o
4 SLOPE GRADE 2io MIN. .0 PAYED AREAS, DINING N I NCS ( 3 ( — J I �O-
I MAST 1"i,4S�'�i�
I izOOM z z � Io 2' 411- yj
3ATH �3 Di�001"i I
o Iz
I I I L 0
— -- — — — — — — — — — — — — — — — — — — — — — — I I o I
I (o'-O" x 4'-On 4'-U x I o 0
{ 5'-0" x 1'-6" 2'-0" x 31-0" — S'-O" — — — — — — — -- I T ALJ
i - - - - - - - - - - - - - - - - -
iI L — — — — — — — — — — — — — — — - - - - - - - - - - - - - - -
I I ® L V
O1„I 5EDROO1"I I _.
I �3�Di�0 Q)
I o�
ff
LOWER FLOOR P- LAN
CIO
I I
I
I I
I ICUPERTINO (�
I 2 , S f
{ 6'-0" I N
I — — — — — — — — — — — — — — — — — — — — — — — i
— — — — — — — 10-o I vieweO 6v
I
2'-6"
2.4 2'-4" 2'-4"
I I
I
o LEGEND
I i
I
5EDROO1„I o I
I
� T L, UNDj2'y' 5EDi2OO1„I Q I EXISTING UlALLS DRAWN
O p x I MM
I X
2'-411 I - - - - - -
WALLS TO BE REMOVED CHECKED
MM
DATE
I I APRIL 16, 2013
I I SCALE
A6 SHOWN
o I JOB NO,
{ I 1251
I I
SHEET
IL - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - -
0 0 o
FL00" LAN
OF SHEETS
NO CHANGE
I REVISIONS BY
FLOOR FLAN NOTES REQUIRED EG=RESS DOOR THRESHOLDS MAY BE 1.5" IN HEIGHT
MAX. OTHER DOORS MAY HAVE A THRESHOLD OF 1-15"
INSTALL 1/2" GYP BRD ON GARAGE SIDE OF WALLS COMMON
REGARDLESS OF DOOR SWING, CRC. 8311,31
TO LIVING SPACE AND 5/5" TYPE "X" GYP. ONE- HOUR FIRE-RESISTIVE
CONSTRUCTION TO BE PROVIDED ON THE GARAGE CEILING WHEN
LIVING SPACE IS ABOVE THE GARAGE, APPLY TO WALLS, POST
AND BEAMS OF GARAGE ADJACENT TO AND SUPPORTING THE
RESIDENCE, APPLIED VERT, OR HORZ, NAIL W/6d COOLER OR
WALLBOARD NAILS o I" OC W/ END JOINTS O/ NAILING MEMBERS,
STAGGER JOINTS EA, SIDE.
ALL INTERIOR WALLS SHALL BE COVERED WITH 1/2" GYPSUM WALL BOARD
EXCEPT OTHERWISE NOTED,
GYPSUM WALL BOARD SHALL BE INSTALLED PER CURRENT U,B,C,
PRINTED O
INSTALL 5/8" TYPE "X" GYP. BD, ON WALLS AND CEILING April 16, 2013
e USABLE UNDER STAIR CLOSET, WHERE APPLICABLE,
THE PLANS,IDEAS AND DESIGNS SHOWN
ON THESE DRAWINGS ARE THE PROPERTY
WALL COVERING SHALL BE CEMENT BACKER BOARD, TILE OR mn
OF TH£D£SIGN£R. DEVISED SOL£Y FOR
APPROVED EQUAL TO l2 ABOVE DRAIN AT SHOWERS
THIS PROJECT. PLANS SHALL NOT BE
OR TUB WITH SHOWERS. MATERIALS OTHER THAN
USED,WHOLE OR IN PART,FOR ANY
STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT,
OTHER PURPOSE WITHOUT THE WRITTEN
PERMISSION MICHELLE MINER DESIGN
PROVIDE WATER RESISTANT GYP, BD. ON ALL "WET" AREAS.
OPENINGS AROUND GAS VENTS, DUCTS d PIPING '
o EACH FLOOR SHALL BE FIRE STOPPED
53
ALL DUCTS IN GARAGE THAT PASS THRU LIVING/GARAGE
O
COMMON WALL SHALL BE 26 GA, STEEL OR THICKER
i Q V
PROVIDE FIRE STOPS IN OPENINGS o FLOOR
CEILINGS OF ALL FIREPLACES
FIREPLACE INSTALLATION AND USE SHALL BE IN
ACCORDANCE WITH THERE LISTING d LOCAL CODES,
0 Q1
i _
DRAFTSTPOOING SHALL BE INSTALLED IN ALL ATTIC SPACES (o^ .� O
OPENING OPENING OPENING V J
AND CONCEALED ROOF SPACES SUCH THAT NO HORIZONTAL
AREA EXCEEDS 3,000 S.F. c
R cn
ai
PROVIDE 13/a" THICK SOLID CORE DOOR W/ CLOSER 7cc
Cj
FROM GARAGE TO RESIDENCE, 0 CX)� c
G
EXTERIOR DOORS SHALL BE i-3/4" THICK SOLID CORE,
N Q �
EXCEPTIONS: EXTERIOR DOORS 1-3/4" THICK WITH SOLID
WOOD PANELS NOT LESS THAN 9/16" THICK ARE A SATIS-
FACTORY ALTERNATIVE TO A SOLID CORE DOORS,
NEW SOLID CORE DOOR C) 0)
WITH SELF CLOSING HINGE
VENTILATING OPENINGS SHALL BE COVERED WITH METAL MESH WITH NOOK WALL �
MAX, 1/4 OPENINGS,
NEW 1/2" SHEETROCK 00
F,A,U, d WATER HEATER INSTALLED ON IS" HIGH WOOD WHERE DOOR WAS
PLATFORM W/ I 1/S" PLYWOOD TOP SURFACE,
INSTALL SEISMIC STRAP ON ALL WATER HEATERS
WATER HEATERS AND FURNACES TO BE CEC
CERTIFIED, WATER HEATERS TO HAVE PRESSURE 3
TEMPERATURE RELIEF DEVICES d DISCHARGE t0 OUTSIDE
STRAPS TO BE INSTALLED AT POINTS WITHIN UPPER 1/3NEW TEMP 7
AND LOWER 1/3 OF IT'S VERTICAL DIMENSIONS. AT LOWER -- STP 2'-0" x 4'-O"
POINT, A 4" CLEARANCE SHALL BE MAINTAINED ABOVE
CONTROLS, WHEN LOCATED IN GARAGE.
I i
SEE DETAIL SHEET EM
WINDOWS MARKED AS "EGRESS" MUST MEET U,B,C,
MINIMUM REQUIREMENTS, OF MAX 44" HIGH SILL 3 MIN,
NET CLEAR OPENINGS OF 20" IN WIDTH 8 24" IN
HEIGHT W/ MIN. CLEAR OPENING OF 51 SQ. FEET
o �
CRAWL SPACE ACCESS TO BE 15" X 24" MIN. z
w
ATTIC ACCESS TO BE 30"X 22" MIN, Q
0.
INTERIOR HANDRAILS d GUARDRAILS TO BE WOOD. W
EXTERIOR HANDRAILS t GUARDRAILS TO BE W.I. I I O
UNLESS OTHERWISE NOTED,
ALL GLASS DOORS, GLASS WITHIN 24" OF DOORS 4 "
d WITHIN 18" OF FLOOR, GLASS SUBJECT TO
HUMAN IMPACT, ETC SHALL BE SAFETY TEMPERED
PROVIDE 2 X SOLID BACKING FOR RAILINGS, CABINETS,
SHELVING, ACCESSORIES, ETC, AS NEEDED,
ADD STUDS TO END OF WALL t0 MATCH
EXTERIOR STUDWALLS TO BE 2 X 4 STUDS 16 O.C. W/ WALL At OTHER SIDE OF HALLWAY V U
BATT INSULATION, (UNLESS OTHER WISE NOTED ' FLAT FRAME BACK OF WALL TO MAKE
CHECK FLOORPLANS.) MORE ROOM IN PANTRY
WINDOWS AND DOOR SIZES SHOWN ARE FOR DESIGN
PURPOSES ONLY, ACTUAL WINDOW t DOOR SIZES
SHALL BE FRAMED d SET PER MRG. SPECIFICATIONS. -tom
MAKE d MODEL NUMBERS SHALL BE CALLED OUT PER
SUPPLIERS AND OR OWNERS SPECIFICATIONS.
WINDOWS TO BE DUAL-PANED (U.N.O,) - F
ff
011
oAILINSTALL ALL WINDOWS AND DOOR AS PER MANUF. SPECIFICATIONS V
ATTICS WITH A VERTICAL HEIGHT OF 30" OR MORE REQUIRES ACCESS.ALL ATTICS ACCESS ARE A 1/2" PLYWOOD PANEL FINISHED WITH A GRADE
REMODEL
SIDE TO THE OCCUPIED SPACE, PAINT TO MATCH THE CEILING TO THE PLY
WOOD PANEL, BATH U
ATTIC FURNACE: MINIMUM OF 5' IN HEIGHT OF CLEAR SPACE. A
Cl[
CONTINUOUS ACCESSIBLE OPENING AND PASSAGEWAY WITH A MIN,
OF 22' X 30" IN SIZE OR AS LARGER AS THE SMALLEST PIECE OF �
r
EQUIPMENT. MAX. 20 FEET TRAVEL PATH AND 24" WIDE W/ SOLID
FLOOR PASSAGEWAY, MIN, 30" X 30" WORKING PLATFORM IN FRONT
OF THE ENTIRE FIREBOX, A PERMANENT ELECTRICAL OUTLET AND 'v
o
LIGHTING FIXTURE. SEE DETAIL SHEET EM c::
ACCESSIBLE UNDER-FLOOR AREA SHALL BE PROVIDED WITH A MIN. 5'-O x 1'- -v
6 v
18" X 24" OPENING. UNDER-FLOOR AREA SHALL BE VENTILATED BY
OPENINGS OF A NET AREA OF NOT LESS THAN 1/150 OF UNDER-FLOOR HALF WALL
t
AREA. VENTILATED OPENINGS SHALL BE PROTECTED BY METAL MESH _ �`� ��� �r
WITH A 1/4" MAX, OPENING,
7'
CONTRACTOR SHALL PROVIDE GALVANIZED SHEET METAL PAN
UNDER ALL CLOTHES WASHER, WHEN LOCATED ON AN UPPER FLOOR.
C'II�EI'Lr .1. F0R' +;fit C I�dJ'YF�LIf�!\1�F
ALL DIMENSIONS ARE TO THE FACE OF STUDS,
FLASH ALL EXTERIOR OPENINGS WITH SHEET METAL TO EXTEND
6" UNDER BUILDING PAPER BEHIND WALL OPENING,
CABINET MANUFACTURER SHALL PROVIDE SHOP DRAWINGS FOR
CONTRACTOR, OWNER, OR HIS AGENT'S APPROVAL FOR ALL CABINET
SIZES AND FINISHES, MATERIAL ETC.. SHOP DRAWING SUPERCEDE ALL
INTERIOR ELEVATIONS,
DRAWN
MINIMUM 26 GAGE IN THICKNESS FOR ALL AIRDUCTS PASSING THRU THE
MM
WALL TO THE GARAGE,
CHECKED
LANDINGS SHALL HAVE A WIDTH NOT LESS THAN A WIDTH OF THE
MM
DOOR OR A STAIRWAY,
DATE
STAIRWAYS: 36" MINIMUM WIDTH, 'l 3/4" MAX. RISE, 10" MIN. RUN AND6'-S"
APRIL 1(0, 2013
MIN, HEAD ROOM
LEGEND SCALE
TOILETS TO HAVE MIN, 30" WIDE X 24" DEEP CLEARANCE.
AS SHOWN
PROVIDE WALL CLEAN-OUT FOR ALL SINKS NEW WALLS
JOB NO,
. �.. 1251
CEILING HEIGHT OF ALL ROOMS TO INCLUDE FLOOR FINISH, S1-IFFY
PROVIDE COMBUSTION AIR FOR SOLID FUEL BURNING APPLIANCES � � EXISTING WALLS QD D DDD PLAN
NEW OPENINGS SHOWN DIMENSIONED
OF SHEETS
REVISIONS BY
fOLUM5ING/ELECTRICAL/MECHANICAL NOTES. 3ATN
GENERAL WALL COVERING SHALL BE CEMENT BACKER BOARD,TILE OR APPROVED EQUAL TO 12"
4OVE DRAIN AT SHOWERS OR TUB WITH SHOWERS, MATERIALS OTHER THAN STRUCTURAL
INSTALLING CONTRACTOR TO DESIGN 4 BUILD COMPETE AND FUNCTION SYSTEM5, (ELEMENTS TO BE MOISTURE RESISTANT,
OWNER TO SELECT ALL ELECTRICAL FIXTURES, EQUIPMENT AND DEVICES ,)HOWER LINING REQUIRED IN PERMANENT BUILT IN SHOWER SEATS UP THE WALL 3" AND
INCLUDING 5WITCHE6 AND OUTLETS NOT OTHERWISE SPECIFIED, PITCHED 1/4" PER FT,
FIELD VERIFY LOCATION OF ALL OUTLETS, LIGHTS, TELEPHONE,CABLE JACKS AND f)HOWER COMPARTMENTS SHALL BE A MIN OF 1024 S,I, AND SHALL BE CAPABLE OF ENCOMPASSING A 30" CIRCLE,
ELECTRICAL EQUIPMENT WITH OWNER, PROVIDE WATER RE515TANT GYP, BD, ON ALL "WET" AREAS,
GENERAL LIGHTING MUST BE FLUORESCENT OR ON A DIMMER OR MANUAL ON-OCCUPANCY SENSOR. PROVIDE TEMPERATURE MIXING AND PRE56URE BALANCE VALVE AT ALL SHOWERS
PRINTED ON
LIGHTING AT NEW CLOSETS UNDER 10 SF IS EXEMPT FROM TH15 REQUIRMENT. IbROWERHEAD5, LAVATORY AND SINK FAUCETS SHALL HAVE A MAX, FLO RATE OF 2,5 GPM
April 16, 2013
NEW OUTDOOR LIGHTING ATTACHED TO BUILDINGS SHALL BE HIGH EFFICACY "OILETS SHALL USE NO MORE THAN 1,6 GALLONS PER FLUSH PER HEALTH AND SAFETY CODE,
OR CONTROLLED BY BOTH A MOTION 6EN50R AND PHOTO CONTROL, "OILETS TO HAVE MIN, 30" SIDE X 24" DEEP CLEARANCE IN FRONT OF TOILET AND A MIN, 15"
THE PLANS,IDEAS AND DESIGNS SHOWN
LIGHTING NOT ATTACHED TO THE BUILDING (LE, LANDSCAPE LIGHTING 15 (,LEAR FROM CENTERLINE OF TOILET TO EACH SIDE,
ON THESE DRAWINGS ARE THE PROPERTY
FOR
EXEMPT FROM TH15 REQUIREMENT BATHROOM LIGHTS TO BE HIGH EFFICACY OR ON A MANUAL ON OCCUPANCY 5EN50R SWITCH
NEW EXTERIOR ELECTRICAL FIXTURES TO BE SUITABLE FOR WET LOCATIONS ALL OUTLETS WITHIN 6-0 OF ANY SINK OR WET LOCATION TO BE GFI PROTECTED OF THE DESIGNER. DEVISED EY
n i THIS PROJECT. PLANS SHALL NOT BE
i i USED,WHOLE OR IN PART,FOR ANY
ALL CAN LIGHTS TO BE IC 4 AT RATED, LIGHTS OVER SHOWER AND TUBS MUST BE WATERPROOF OTHER PURPOSE WITHOUT THE WRITTEN
NEW LIGHTING FIXTURES IN CLOSETS TO HAVE THE FOLLOWING CLEARANCES A DEDICATED 20 AMP CIRCUIT SHALL BE PROVIDED TO SERVE BATHROOM OUTLETS
' I PERMISSION MICHELLE MINER DESIGN
TO COMBUSTABLE SHELVES: THIS CIRCUIT SHALL NOT SUPPLY ANY OTHER OUTLETS, LIGHTS OR FANS
1, SURFACE MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12" CLEAR AND ENCLOSED LAMP A SEPARATE CIRCUIT 15 REQUIRED FOR HYDROMABAGE BATHTUBS AND GFI PROTECTED AND BONDED
2, FLUORESCENT 4 RECESSED FIXTURES TO HAVE MIN, 6" CLEARANCE '10TOR5 SMALL BE UL L16TED FOR HYDRO MA55AGE USE AND A REMOVABLE PANEL OF SUFFICIENT 0
ALL NEW EXTERIOR OUTLETS TO BE GFI PROTECTED AND INSTALLED IN A WEATHER PROOF BOX )IMEN5KON SHALL BE INSTALLED TO ACCESS PUMP.
NEW EXTERIOR OUTLETS TO BE WITHIN 6-6 OF FINISH GRADE 4) 0
REQUIRED � �� 4LL BATHROOMS REQUIRE A VENT FAN WITH MIN, 50 CFM, '
ALL REQ. 15/20 AMP RECEPTACLES LISTED IN SECTION 210,52,SHALL BE L15TED TAMPER RE515TANT
4LL VENT 'tERMINATI0N5 MUST BE 10' AWAY OR 3' ABOVE ANY OPENING. TYP. ¢ .� U
RECEPTACLES PER CEC 406,11
NEW OUTLETS AT FAMILY ROOMS,DINING ROOMS,LIVING ROOMS, BEDROOMS,CLOSETS,
- 0
HALLWAYS, AND SIMILAR ROOMS/AREAS SHALL BE PROTECTED BY LISTED ARC-FAULT CIRCUIT
INTERUPTER,COMBINATION-TYPE PER CEC 210,12
0 N
Cz
ALL GARAGE OUTLETS TO BE GFI
GAS SHUT OFF VALVE FOR FIREPLACE TO BE INSTALLED OUTSIDE OF THE HEARTH AREA, MIN, 36" Cz
AND MAX OF 48" FROM GAS SUPPLY VALVE. (D.— 0
�
NEW HOSE 81556 SHALL BE PROVIDED W/ ANTI SIPHON VALVES
NO REQUIRED UNDERFLOOR CLEAN-OUT SHALL BE MORE THAN 20' FROM AN ACCESS DOOR (CPC 101,10) F
N
PROVIDE WALL CLEANOUT5 FOR ALL NEW 51NK5 (D (D -6 a)
SMOKE DETECTORS TO BE AC/DC
WITH A BATTERY BACK UP AND LOCATED WITHIN EACH SLEEPING ROOM
co
AND AT A POINT CENTRALLY LOVCATED OUTSIDE EACH SLEEPING ROOM. ALL FLOOR LEVELS SHALL HAVE
D
A SMOKE DETECTOR
AN SHALL BE INTERCONNECTED,UL LISTED 4 CALIF, STATE FIRE MARSHALL APPROVED,
CARBONE MONOXIDE DETECTORS SHALL BE LOCATEDAT A POINT CENTRALLY LOVCATED OUTSIDE EACH SLEEPING ROOM.
O cf3
00
KITCHEN: 00
AT LEAST 5O% OF TOTAL WATTAGE OF KITCHEN LIGHTING TO BE HIGH 00
T
EFFICACY,
ALL HIGH EFFICACY KITCHEN LIGHTING TO BE SWITCHED 5EPERATLELY IN a
FROM LOW EFFICACY LIGHTING, in
PROVIDE AT LEAST 2-20 AMP DEDICATED SMALL APPLIANCE CIRCUITS
AT KITCHEN COUNTER TOPS ELECTRICAL SYMBOL
PROVIDE DEDICATED CIRCUITS FOR: DISHWASHER,GARBAGE DISPOSAL,
TRASH COMPACTOR AND BUILT IN MICROWAVE Fan Light Combo
PROVIDE COUNTER TOP OUTLETS AT 48" OC MAX
PROVIDE AT LEAST ONE COUNTER TOP OUTLET FOR COUNTER TOP 12" To DISPOSAL
fluorescent barOR WIDER
PROVIDE AT LEAST ONE COUNTER TOP OUTLET FOR ISLAND OR
PENNISULA COUNTERS WITH A LONG DIMENSION OF 24" OR GREATER gas bibb �• {}}— 1
AND A SHORT DIMENSION OF 12" OR GREATER
ALL KITCHEN COUNTER TOP OUTLETS TO BE GFI PROTECTED I
can light
NO DISHWASHING MACHINE SHALL BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR FOOD
DISPOSER WITHOUT THE USE OF AN APPROVED AIR GAP FITTING ON THE DISCHARGE 51DE OF THE
DI5H-WA5HING MACHINE pendant cone ----- I
PROVIDE GAS 5HUT-OFF o STOVE IN AN ACCE66ABLE LOCATION I i
' �` `_—�� VERIFY SMOKE DETECTOR IN EACH SLEEPING ROOM ([�
RANGE HOOD MUST EXTEND FULL WIDTH OF RANGE, INSTALL PER MANUF, SPECIFICATIONS, / I I AND ONUST OUTSIDE EACH SLEEPING ROOM AND A —V
T TERMINATE A MIN. OF 3' FROM ANY AIR INTAKE OR OPENING INTO THE DIMMER D --�-' i � ,� �\� � i I CARSON MONOXIDE DETECTOR JUST OUTSIDE EACH
RANGE HOOD MU5 $ ^•
i SLEEPING ROOM ON EACH FLOOR O
BUILIDING, J
carbon monoxide detector co '
WATER HEATER �' P-64 va
co
light - - - Q
WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO THE STRUCTURE,
PROVIDE 11/2 X 16" GAUGE STRAPS AT TOP AND BOTTOM WITH 3/8" DIA X 3° Qk,-) DIRECTIONAL
LONG LAG BOLT AT EACH END.
THANKLESS WATER HEATERS LOCATED WITHIN HABITABLE SPACE REQUIRE manual on occupancy sensor switch
MANUF, SPEC. FOR COMBUSTION AIR SUPPLY AND VENTING '� `
0
outlet o ® L
FURNACE:
outlet 220V
AN APPROVED, INDEPENDANT MEANS OF DISCONNECT FOR THE ELECTRICAL SUPPLY TO (�
EA, PIECE OF EQUIPMENT SHALL BE PROVIDED WITHIN SIGHT OF THE EQUIPMENT SERVED WHEN outlet gfi I I i– �✓
THE SUPPLY VOLTAGE EXCEEDS 50 VOLTS, (CMC 308, CEG 422,31(5),CEC 422,33(A)) '
(T HA BE PROVIDED FOR THE FURNACE, (CEC 422,12) I
A DEDICATED CIRCUIT SHALL I
A 120 VOLT SERVICE RECEPTIACLE SHALL BE LOCATED WITHIN 25 FEET OF, AND ON THE smoke detector ® '
SAME LEVEL AS, THE EQUIPMENT FOR MAINTENANCE, THE SERVICE RECEPTACLE SHALL NOT BE
CONNECTED ON THE LOAD SIDE OF THE REQUIRED MEANS OF DISCONNECT, (CMC 308) switch $
A PERMANENT SWITCH CONTROLLED LIGHTING FIXTURE SHALL BE INSTALLED FOR MAINTANENCE
OF EQUIPMENT AND SHALL BE ACCESSIBLE, SUCH FIXTURE SHALL PROVIDE SUFFICIENT r
wall sconce
ILLUMINATION TO SAFELY APPROACH THE EQUIPMENTAND PERFORM THE TASKS FOR WHICH
THE ACCESS 15 PROVIDED, CONTROL OF THE LIGHTING SHALL BE PROVIDE AT THE ACCESS C: K3
ENTRANCE, (CMC 904,11.5,CEC 210,10) (CID
�
COMBUSTION AIR MUST BE MAINTAINED (CMC CHAPTER 1) �✓
THE CLEAR SPACE AND DISTANCE TO COM5USTABLE MATERIALS AROUND THE FURNACE UNIT SHALL
COMPLY WITH THE MANUF, INSTALLATION INSTRUCTIONS, (CMC 904,2)
A SED ,
SEDIMENT TRAP SHALL BE INTSTALLED ON THE GAS LINE DOWNSTREAM OF THE �`
APPLIANCE SHUT-OFF VALVE AND A5 CLOSE TO THE INLET OF THE EQUIPMENT A5 PRACTICAL i ^'
I J!'' iYicJcI7�lEsn?
(CPC 121211)
APPLIANCES GENERATING A GLOW,SPARK,OR FLAME CAPABLE OF IGNITING FLAMMABLE
, I
,' 's
VAPORS MAY BE INSTALLED IN A GARAGE PROVIDED THE PILOTS,BURNERS OR HEATING
ELEMENTS AND 5WITCHE6 ARE A MIN, OF 18" ABOVE THE FLOOR LEVEL, (CMC 301,1)
EXCEPTION: SEALED COMBUSTION SYSTEM APPLIANCES MAY BE INSTALLED AT FLOOR
LEVEL
WHEN LOCATED IN A GARAGE AND SUBJECT TO VEHICULAR DAMAGE,ADEQUATE BARRIERS
MUST BE INSTALLED (EG,4" DIAM, STEEL PIPE FILLED WITH CONCRETE INSTALLED IN A FOOTING
MEA5UREING 12" RND, AND 3' DEEP), (CPC AND GMC 301,1)
THE FURNACE SHALL BE PROPERLY ANCHORED AND SUPPORTED TO SUSTAIN VERTICAL
AND HORIZONTAL LOADS WITHIN THE STRE55 LIMITATIONS SPECIFIED IN THE CALIFORNIA
DRAWN
BUILDING CODE (CPG 4 CMC, 303,4)
MM
CHECKED
LAUNDRY: Mm
DATE
PROVIDE A MIN OF ONE 20 AMP LAUNDRY BRANCH CIRCUIT, SUCH CIRCUIT SHALL HAVE
APRIL 16, 2013
NO OTHER OUTLETS (CEG 210-23(A)) LEGE ND
SCALE
VENT DRYER TO OUTSIDE W1 MIN, 4" RND BY W MAXIMUM LENGTH DUCT
As SHOWN
INCLUDING NO MORE THAN 2-90 DEGREE ELBOWS AND EQUIPED W/ BACK DRAFT DAMPER
F�hNEW WALLS JOB NO,
1251
EXISTING WALLS SHEET
V4 "
o MECHANQCAL �LAN EM