Loading...
14030037 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1072 ANDY LN CONTRACTOR:SAM LIEM PERMIT NO: 14030037 OWNER'S NAME: SAM LIEM 10726 RANDY LN DATE ISSUED:04/15/2014 OWNER'S PHONE: 4087688709 CUPERTINO,CA 95014-2055 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL E] COMMERCIAL E] CONVERT(E)STORAGE AREA TO(N)SEPARATE LIVING License Class Lic.# UNIT(GRANNY UNIT 383 S.F.). (POSSIBLE CODE CASE FOR ILLEGAL BATHROOM IN (E)DETACHED GARAGE Contractor Date AREA I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$8000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:31602072.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST-GA-L" INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the t/ �s-- granting of this permit. Additionally,the applicant understands and will comply Date: b with all non-point source regulations per the Cupertino Municipal Code,Secti -� 9.18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for 10 inspection. OWNER-BUILDER DECLARATION 'I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: � Date:`"'�l permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes,(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature /�/ Date /"� � CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 0D CUPERTINO ELI (408)777-3228• FAX(408)777-3333• bulldiricAcupertlno.org \, ❑NEW CONSTRUCTION ❑ ADDITION ALTERATION/TI ❑ REVISION/DEFERRED �IORIGINAL PERMIT# PROJECT ADDRESS / �f ' /{/w / APN tt — O O 7h OWNER NAME L./ ^rn � PHONE (D E-MAIL L_- /:e*-t ha�cam,, STREET ADDRESS `^� ,{!,4 n `V CITY,STATE,�.IP�7/N,) ��G�'r' FAX CONTACT NAME U�J`_- - ��l�J711.(/ PHO 0C�,(^J���_ 701 E-MAIL 1 y4 A DU, .let� Li.cw, o� com STREET ADDRESS CITY,STATE,ZIP FAX ❑OWNER Cl OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME /� LICENSE NUMBER LICENSE TYPE BUS.LIC# i v COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME 1 G L LICENSE NUMBER ¢ O 4 ,F 7 BUS LIC# /, COMPANY NAME ixet�j` `V S410VIMf- CRA090-1T E-MAIL v ( `-/ !! FAX STREET ADDR SS '' C> (,y CITY,STATE,ZIP �C2CMO.17' C4&)yM PHON_/ 0�5V6_(Sgg DESCRIPTION OF WORK �`�� PHO? CaNve:/LT OLQ q-v^4-C_ To S%olQ4j:, P~ousw ftxr/*- PvALc To MC-L-7 Ser? AWic v►K Ea'r►�T. CPAs vent S7'0144SLc To 2 '� vN/T w/Tu AI& vv/;*K&7;1 A4Do)c. !L� -/26101f-- EXISTING USE PROPOSEDUSE CONSTR TYPE ft STORIES USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA -3 Q 3 AREA NET AREA BATHRCIO n KITCHEN OTHER REMODEL A ( !� REMODEL AREA REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA; DETACH ❑ATTACH #DWELLING UNITS IS A SECOND UNIT ❑YES SECOND STORY ❑YES BEING ADDED! []NO ADDITION° []NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YESCEI ` TOTAL VALUATION: PLANNING APPL# []NO PLANNING APPROVAL LETTER EICHLER HOME.' r-1NO ©DO By my signature below,I certify to each of the following: I am the property owner or amdfoorized agent to act on the owner's behalf. 1 have read this application and the information 1 have provided is correct. I have read the Description of Work and verify it is ac e. 1 agree to comply with all applicable local ordinances and state laws relating to building construe on. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED PLANCIIECKTYPE ROUTINGSLIP' New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVERTIRE-COUNTER 0 BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials DisclosureSTANDARD © PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ©'FJRE DEPT Copy of Planning Approval Letter or Meeting with Planning prior to submittal Of Building Permit application. 13 MAJOR, El SANITARY SEWER DISTRICT ❑ ENVIRONMEINTAL HEALTH BldgApp 201 Ldoc revised 0612///1 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 10726 RANDY LN DATE: 03/05/2014 REVIEWED BY: MELISSA APN: 316 02 072 BP#: O 1 'VALUATION: 1$8,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: New Construction PRIMARY SFD or Duplex 2nd Unit? G Yes 0 No PENTAMATION 1 R3SFD2ND USE: PERMIT TYPE: WORK CONVERT STORAGE AREA TON LIVING SPACE 383 S.F. POSSIBLE CODE CASE FOR SCOPE ILLEGAL BATHROOM - NON PERMITTED) OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID CONSTR. s.f. R-3 (Custom) II-B,111-B,IV,V-B 383 $2,577.00 IR3PLNCK $1,617.00 IR3INSP TOTALS: 383 $2,577.00 $1,617.00 NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the preliminar information available and are only an estimate. Contact the De t or addh 7 info. FEE ITEMS (Fee Resolution 11-053 F/f 7"1 '13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $2,577.00 Select a Misc Bldg/Structure Suppl. PC Fee: ) Reg. ) OT 0.0 hrs $0.00 or Element of a Building PME Plan Check: $0.00 Permit Fee: $1,617.00 Suppl. Insp. Fee:') Reg. ) OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 #new Construction Tax: 1BCONSTAXR 1 units $652.28 0 Work Without Permit? 0 Yes ) No $0.00 ) Advanced Planning Fee: 1PLLONGR $53.62 Select a Non-Residential ) Building or Structure 0 Strom Motion Fee: 1BSEISMICR $0.80 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $4,901.70 $0.00 TOTAL FEE: F$4,901,701 Revised: 01115/2014 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RT I N O Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: 107p- g,47,jVV LA! PERMIT# 0-3 D D OWNER'S NAME: L PHONE # GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTIONS) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/ Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner Contractor Signature Date Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RTI N O Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: U &7 1--/✓ PERMIT# /�L © S 00.5 OWNER'S NAME: 56111 L PHONE# tlot — 76 drF7w GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. �( A6� I am not using any subcontractors: /� :?/2 7/1 0 ` ignature Date Please check applicable subcontractors and complete the following information: ✓ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring /Carpeting Linoleum/Wood Glass/ Glazing Heating Insulation Landscaping Lathing Masonry Painting /Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile '�R / C Ow4r/Contractor Signature Date OWNER-BUILDER DISCLOSURE FORM K COMMIUNI IY DEVELOPMENT DEPARTMENT •BUILDING DIVISION 016, 10300 TORRE AVENUE• CUPER T INO,CA 95014-3255 (408)777-3228• FAX(40B)777-3333• buildino(a;cuoertino.ora CUPErRTING Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE„DDRESS AF h4 aP„ 07 R IVO 3(4 - b - Z �4 3 00� - 0WKIER NAIdE OWNER ADDR=SS 5 DESCRIPTION OF WORK: C 0/06_47/ C F -6 Tv 9476-6--- TO W 2Ail _ PW 671110 We are providing you with an Ov✓ner-Builder Acknowledgment and Information Verification Form to make you av✓are of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. `«Ve \vill not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our ofr1cial address indicated. An agent of the owner cannot execute this notice unless you,the property owner, obtain the prior approval of the permitting authority. CWS 4ER'S ACKNOWLEDGIliENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or verity this information.) I- I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- uilder"building permit that erroneously implies that the property owner is providing his or her own labor and material personally, I, as an Owner-Builder,may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. L2. I understand building permits are not required to be signed by propery.owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. 1 understand as an "Owner-Builder" 1 am the responsible parry of record on the permit. I understand that l may protect myself from potential financial rsk by hiring a licensed Contractor and having the permit lied in his or her name instead of my ov✓n. krs I understand Contractors are required by law to be licensed and bonded in California and to list their license on permits and contracts. L5. I.understand if I employ or othenl✓ise engage any persons, other than California licensed Contractors, and the total value of my construction is at least rive hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. 6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal gover :ment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensatlon for each "employee." I also understand my failure to abide by these laves may subject me to serious financial risk. ?/7. I understand under California Contractors' State License Law, an Ovvner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. (71 8. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for anyfinancial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. 0+:;�e;Lui?derFor,n ZOI0.docrevised 04111110 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand l may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752)or v,nw✓,cslb.ca.gov for more information about licensed contractors. V 10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and undersand that I am the pa-iy legally and financially responsible for proposed construction activity at the site address listed above. V—/ i 1. I aoree that, as the party legally and financially responsible forthis proposed construction activity, l will abide by all applicable laws and requirements that govern Owner-Builders as well as employer. V—/12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with sorneone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status L)theirv�,orker' compensation insurance coverace, CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby ai51m that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other ver>nation acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: /LSI fig --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The rolloiving Authorization Form is required to be completed by the popery owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNEPUS BEHALF Excluding the Notice to Property Ov✓ner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s)to apply for, s on, and file the documents neCcSSHry to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of\Vork): Project Location or Address: Name ofAuLhonzed Agent: Tel No r ddress cf Authorized Agent: declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and cer riy its accuracy. Note:A copy of the properly oV✓ner's driver's license, form notarization, or other verif7cation acceptable to the city may be required to be presented when the permit is issued to verily the property owners signature. Property Owner's Signature: Date: 0l%'7er3ui?de7Foa7n ?010.doc revised 04/1'110 Building Department CITY OF CUPERTINO 10300 TORRE AVENUE • CUPERTINO,CA 95014-3255 C U P E RT I N O TELEPHONE:(408)777-3228 • FAX: (408)777-7606 OFFICIAL NOTIFICATION OF NEW/ADDRESS CHANGE TO: All Agencies FROM: City of Cupertino DATE: August 07, 2014 RE: New/Change of Address APN #316-02-072 Please note the following new address assignment: 10726 Randy Ln is the main house address and 10728 Randy Ln is being assigned to the detached 2nd unit. See attached map. The new address will take effect 30 days from the date of this letter. Please update your records accordingly. If you have any questions, please call me at (408) 777-3246. Sincerely, Susan Winslow Administrative Clerk Cupertino Building Dept 408-777-3246 or suew@cupertino.org City of Cupertino Basemap Labels Street Namesi..r.."r•Ti Secondary Address Labels Primary Address Labels Freeway Basemap _� ____ •+� . Street Centerline County Major Roads ' County Freeways Right-of-Way .' Parcels Community Development o City Boundary ® Aerials - Sept 2013 r a� IML ' • ti' t SCALE 1 : 664 50 0 50 100 150 / Lf7c,2/ FEET http://gissvr/cupertinointranet/home/mapFile.aspx Tuesday, August 05, 2014 10:30 AM CALGREEN RESIDENTIAL CHECKLIST — MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION CUPERTINO ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 S U ; i 1 L (408)777-3228• FAX(408)777-3333•building(a�cupertino.org PURPOSE: #9 The 2013 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory-built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. CES s Pc9vc��T Project Name: CONV6kr(F)S%0/4+4'V 710 C/y9 2"4 &V&-tUA4- VN/T- � 305o z Project Address: I o7a6 9A1vPy LA/, C v/kc9t7iwd' 5 Project Description: 9.°'D VwrljI AJ (,oiv VMTJ OnJ SF 8uildinq DeDaltment Instructions: EVIf IVF(, f Uft GC?UE C,GMPLIANCE 1. The Owner or the Owner's agent shall employ a licensed profession alreAp@g% c d with.0e Calif r la Green Building Standards Codes to verify and assure that all required work descrhbed­ efWTh is,0_11,d l planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, t ed professional shall complete Column 3 and sign and date Section 2 - Implementation Veri 'c of this checklist and submit the completed form to the Building Inspector. k Column 2 Column 3 MANDATORY FEATURE OR MEASURE Project Verification Re uirements A4.1 PLANNING AND DESIGN Planning and Design -Site Development 4.106.2 Storm water drainage and retention during construction. A plan is developed and implemented to manage storm water drainage during ❑X �] construction. 4.106.3 Grading and paving. The site shall be planned and developed to ❑ keep surface water away from buildings. Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. °49 Page I of 5 CalGreen 2014.doe revised 01115/14 A4.2 General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. A4.3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use 4.303.1 Water conserving plumbing fixtures and fittings. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads)shall comply with the following: ❑ 4.303.1.3.2 Water Closets.The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specifications for Tank-type Toilets. ❑ 4.303.1.3.2 Urinals. The effective flush volume of urinals shall not exceed 0.5 gallons per flush. ❑ 4.303.1.3.1 Single Showerheads. Showerheads shall have a maximum flow rate of not more than 2.0 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for showerheads. ❑ 4.303.1.3.2 Multiple Showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all showerheads and/or other shower outlets controlled by a single valve shall not exceed 2.0 gallons per minute at 80 psi, or the shower shall be designed to allow only one shower outlet to be in operation at a time. ❑ 4.303.1.4.1 Residential lavatory faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.5 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. ❑ 4.303.1.3.2 Lavatory faucets in common and public use areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. ❑ 4.303.1.4.3 Metering faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.25 gallons per cycle. ❑ 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. 4.303.2 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1401.1 of the California Plumbing Code. Page 2 of 5 CalGreen_2014.doc revised 01/15/14 Outdoor Water Use 4.304.1 Irrigation controllers. Automatic irrigation systems installed at the time of final inspection shall be weather-based. ❑ 4.304.1.1 Controllers shall be weather-or soil moisture-based controllers that automatically adjust irrigation in response to changes in plants' needs as weather conditions change. ❑ ❑ ❑ 4.304.1.2 Weather-based controllers without integral rain sensors or communication systems that account for local rainfall shall have a separate wired or wireless rain sensor which connects or communicated with the controller(s). Soil moisture-based controllers are not required to have rain sensor input. A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced"Durability and Reduced Maintenance 4.406.1 Rodent proofing. Annular spaces around pipes, electric cables, conduits, or other openings in plates at exterior walls shall be protected ❑ ❑ against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Reduction, Disposal and Recycling- 4.408.2 Construction waste management plan. Where a local jurisdiction does not have a construction and demolition waste management ordinance, a ® ❑ construction waste management plan shall be submitted for approval to the enforcing agency. Building Maintenance and Operation 4.410.1 Operation and maintenance manual. At the time of final inspection, an operation and maintenance manual shall be provided to the building ® ❑ occupant or owner. ENVIRONMENTAL Fireplaces 4.503.1 General. Install only a direct-vent sealed-combustion gas or sealed ® ❑ wood-burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Covering of duct openings and protection of mechanical equipment during construction. Duct openings and other related air ❑X ❑ distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks. Adhesives, sealants and caulks ❑ ❑ shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints and coatings. Paints, stains and other coatings shall be ❑ ❑ compliant with VOC limits. 4.504.2.3 Aerosol paints and coatings. Aerosol paints and other coatings shall be compliant with product weighted MIR Limits for ROC and other toxic ❑X ❑ compounds. Page 3 of 5 CalGreen_2014.doc revised 01/15/14 4.504.2.4 Verification. Documentation shall be provided to verify that compliant VOC limit finish materials have been used. 4.504.3 Carpet Systems. Carpet and carpet systems shall be compliant with VOC limits. 4.504.4 Resilient flooring systems. Eighty (80) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHPS) Low-emitting QX Materials List or be certified under the Resilient Floor Covering Institute(RCFI) FloorScore program. 4.504.5 Composite wood products. Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall ❑X comply with low formaldehyde emission standards. Interior Moisture Control 4.505.2 Concrete slab foundation. Required vapor retarders and capillary breaks are also required to comply with CalGreen Section 4.505.2.1. 4.505.3 Moisture content of building materials. Moisture content of building materials used in wall and floor framing is checked before enclosure. Indoor Air Quality and Exhaust 4.506.1 Bathroom exhaust fans. Exhaust fans which terminate outside the building are provided in every bathroom. Environmental Comfort 4.507.2. Duct systems are sized and designed and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. INSTALLER AND SPECIAL INSPECTOR QUALI�ICATIONS Qualifications 702.1 Installer training. HVAC system installers are trained and certified in the proper installation of HVAC systems. 702.2 Special inspection. The Licensed Professional responsible to verify CALGreen compliance is qualified and able to demonstrate competence in the OX discipline they inspect and verify. Verifications 703.1 Documentation. Verification of compliance with CALGreen may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance. Implementation verification shall be submitted to the Building Department after implementation of all required measures and prior to final inspection approval. Page 4 of 5 CalGreen_2014.doc revised 01115114 CALGREEN SIGNATURE DECLARATIONS Project Name: CDAI VL"� (tP) 670t7l 7-0 Chi) 2rw 1)Wt'ZuACf uN+r Project Address: 1 ° L IZA-tiPy Z.-Iv C�,RF&7/AJ0 , Cot— cl S-0/x Project Description: d p awru.r�- C o r ver a nl '� S�- SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1 —"Design Verification" and submit the completed checklist(Columns 1 and 2)with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Owner's Signature Date Owner's Name (Please Pr �2 Z o/ es' Prof ssional's Signature Date Design Professiona s Name (Please Print) Si e of L' ense P ofessional responsible for CalGreen compliance Date en Name of License P ofessional responsible for CalGreen compliance(Please Print) Phone I o• Email A ress f r License Professional responsible for CalGreen compliance SECTION 2 - IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2013 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance(Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 5 of 5 CalGreen_2014.doc revised 01/15/14 s r BUILDING ENERGY ANALYSIS REPORT PROJECT: Liem 2nd Unit 10726 Randy Lane Cupertino, CA 95014 Project Designer: Michael Shing Construction 34140 Audry Court Fremont, CA 94555 Report Prepared by: Timothy Carstairs, CEA,CEPE Carstairs Energy Calculations PO Box 4736 San Luis Obispo, CA 4'�. .- (805) 904-9048 ei W CUPERTINO Job Number: -#2 � I 8uildinq Departmnt 14-030210 0V 3 Q cor,nPi_IANCE Date: �'�� I ,ev evwed 0 3/26/2014 V � APR 09 ?014 The EnergyPro computer program has been used to perform the calculations summarized in this corrairpnce report.This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. This program developed by EnergySoft,LLC—www.energysoft.com. Ener Pro 5.1 by Ener Soft User Number:6249 Run Code:2014-03-26T16:42:38 ID:14-030210 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF-1 R Certificate of Compliance 3 Form MF-1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 EnergyPro 5.1 by EnergySoft Job Number: ID:14-030210 User Number:6249 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Liem 2nd Unit ❑ Multi Family ❑ Existing+Addition/Alteration 3/26/2014 Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories 10726 Randy Lane Cupertino CA Climate Zone 04 383 n/a 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ftp) Features see Part 2 of 5) Status Wall Wood Framed R-13 585 New Door Opaque Door None 20 New Roof Wood Framed Attic R-30 383 New Slab Unheated Slab-on-Grade None 383 Perim=79' New FENESTRATION U- Exterior Orientation Area(ff) Factor SHGC Overhang Sidefins Shades Status Front(S) 12.0 0.390 0.45 none none Bug Screen New Rear(N) 15.0 0.390 0.45 none none Bug Screen New HVAC SYSTEMS Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Fan Wall Furnace 65%AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status HVAC System Ductless/with Fan Ductless n/a n/a New WATER HEATING Qty. Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.59 No Pipe Insulation New Ener Pro 5.1 by Ener Soft User Number:6249 RunCode:2014-03-26T16:42:38 ID. 14-030210 Page 3 of 12 PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF-1 R Project Name Building Type ® Single Family ❑Addition Alone Date Liem 2nd Unit ❑ Multi Family ❑ Existing+Addition/Alteration 3/26/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist.These items require special written justification and documentation,and special verification to be used with the performance approach.The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF-4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number:6249 RunCode:2014-03-26T16:42:38 ID: 14-030210 Page 4 of 12 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Liem 2nd Unit ❑ Multi Family ❑ Existing+Addition/Alteration 3/26/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r) Space Heating 19.50 18.05 1.45 Space Cooling 3.80 4.99 -1.19 Fans 4.28 4.27 0.01 Domestic Hot Water 62.60 60.74 1.85 Pumps 0.00 0.00 0.00 Totals 90.18 88.05 2.13 Percent Better Than Standard: 2.4% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext.Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 168 12 Fuel Available at Site: Natural Gas (w) 148 0 Raised Floor Area: 0 (N) 168 15 Slab on Grade Area: 383 (E) 148 0 Average Ceiling Height: 8.0 Roof 383 0 Fenestration Average U-Factor: 0.39 TOTAL: 27 Average SHGC: 0.45 Fenestration/CFA Ratio: 7.0% REMARKS STATEMENT OF COMPLIANCE CABER This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the California Assoc11134 TRUM Energy Consultants Efficiency Standards of the California Code of Regulations. TimothYC.rstairs / R08-06-210 The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Carstairs Energy Calculations /26/2014 Address PO Box 4736 Name Timothy Carstairs, CEA, CEPE r City/State/ZipCity/State/Zip San Luis Obispo, CA 93403 Phone (805)904-9048 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Michael Shing Construction Address 34140 Audry Court Name Sam Liem City/State/Zip Fremont, CA 94555 Phone Signed License# Date Ener Pro 5.1 by Ener Soft User Number:6249 Run Code:2014-03-26T16:42:38 ID: 14-030210 Page 5 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R Project Name Building Type m Single Family ❑Addition Alone Date Liem 2nd Unit ❑ Multi Family ❑ Existing+Addition/Alteration 3/26/2014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 136 0.102 R-13 180 90 New 4.3.1-A3 Studio Door 20 0.500 None 180 90 New 4.5.1-A4 Studio Wall 148 0.102 R-13 270 90 New 4.3.1-A3 Studio Wall 153 0.102 R-13 0 90 New 4.3.1-A3 Studio Wall 148 0.102 R-13 90 90 New 4.3.1-A3 Studio Roof 383 0.03 1 R-30 0 0 New 4.2.1-A20 Studio Slab 383 0.730 None 0 180 New 4.4.7-A1 Studio FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments 1 window 6.0 0.390 NFRC 0.45 NFRC 180 New Double Non Metal Clear Studio 2 Window 6.0 0.390 NFRC 0.45 NFRC 180 New Double Non Metal Clear Studio 3 Window 15.0 0.390 NFRC 0.45 NFRC 0 New Double Non Metal Clear Studio (1) U-Factor Type: 116-A=Default Table from Standards, NFRC=Labeled Value 2 SHGC Type: 116-B=Default Table from Standards, NFRC=Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC H t Wd Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 Ener Pro 5.1 by EnergySoft User Number.6249 RunCode:2014-03-26T16:42:38 ID.14-030210 Pa e 6 of 12 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF--1 R Project Name Building Type ©Single Family ❑Addition Alone Date Liem 2nd Unit ❑ Multi Family ❑ Existing+Addition/Alteration 3/26/2014 BUILDING ZONE INFORMATION Floor Area ft System Name Zone Name New Existing Altered Removed Volume Year Built HVAC System Studio 383 3,064 Totals 1 3831 0 01 01 1 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Fan Wall Furnace 65%AFUE Split Air Conditioner 13.0 SEER Setback New HVAC DISTRIBUTION Duct Ducts S stem Name Heating Cooling Duct Location R-Value Tested? Status HVAC System Ductless/with Fan Ductless n/a n/a ❑ New WATER HEATING SYSTEMS Ext. Rated Tank Energy Standby Tank Input Cap. Factor Loss or Insul. R- S stem Name Qty. Type Distribution Btuh al or RE Pilot Value Status Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.59 n/a n/a New MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Hot Water Piping Length (ft) o iv v Pipe Pipe Insul. Control aty. HP Plenum Outside Buried ¢ — System Name Length Diameter Thick. Ener Pro 5.1 by Ener Soft User Number.6249 RunCode:2014-03-26T16:42:38 ID: 14-030210 Pae 7 of 12 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R Project Name Date Liem 2nd Unit 3/26/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance(CF-1 R, CF-1 R-ADD, or CF- 1 R-ALT Form)shall supersede the items marked with an asterisk(*) below.This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4:Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-6R Form. §118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(i)when the installation of a Cool Roof is specified on the CF-1 R Form. *§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value. *§1 Oc :Minimum R-13 insulation in wood-frame wall orequivalent U-factor. *§1 50 d :Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor. §150(f):Air retarding wrap is tested, labeled,and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form. §150(g):Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A:Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B:Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is equipped with a with a readily accessible, operable,and tight-fitting damper and or a combustion-air control device. §150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning,Water Heating and Plumbing System Measures: §110-§113: HVAC equipment,water heaters,showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of§113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1A:Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §150(j)1 B:Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank. §150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §150(j)2:Cooling system piping (suction,chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance,and wind. §150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2014-03-26T16:42:38 ID:14-030210 Page 8 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R Project Name Date Liem 2nd Unit 3/26/2014 §150(m)1:All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601,602, 603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic,tape or other duct-closure system that meets the applicable requirements of UL 181, UL 181 A,or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used §150(m)1:Building cavities,support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tae is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §I50(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance,and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(0):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency Regulations;an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and shall not use electric resistance heating ora pilot light. §114(b)l:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater,or dedicated suction and return lines,or built-up connections for future solar heating. 114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing,flow rate, piping,filters,and valve requirements of§150 Residential Lighting Measures: §150(k)1:High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2. 150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line- voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d), and shall not contain a medium screw-base socket. 150(k)6:Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150(k). 150(k)7:All switching devices and controls shall meet the requirements of§150(k)7. §150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor,dimmer, energy management system (EMCS), or a multi-scene programmable control system;and all permanently installed luminaries in garages, laundry rooms,closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual-on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number:6249 RunCode:2014-03-26T16:42:38 ID:14-030210 Page 9 of 12 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date Liem 2nd Unit 3/26/2014 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms,closets and utility rooms shall be high efficacy. EXCEPTION 1:Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of§119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms,garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual- on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with§150 k 11. §150(k)l2:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC)by Underwriters Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283;and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13:Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches,which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor luminaires used to comply with Exceptionl to§150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14:Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket, and consume no more than five watts of power as determined according to§130(d). §150(k)15:Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134,and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoff User Number. 6249 RunCode:2014-03-26T16:42:38 ID:14-030210 Page 10 of 12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Liem 2nd Unit 3/26/2014 System Name Floor Area HVAC System 383 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 8,000 Total Room Loads 177 3,817 447 168 6,688 Total Output(Btuh) 8,000 Return Vented Lighting 0 Output Btuh/s ft 20.9 Return Air Ducts 0 0 Cooling System Return Fan 0 0 Output per System 10,000 Ventilation 0 0 0 0 0 Total Output Btuh 10,000 Supply Fan 0 0 Total Output Tons 0.8 Supply Air Ducts 0 0 Total Output(Btuh/sgft) 26.1 Total Output s ft/Ton 459.6 TOTAL SYSTEM LOAD 3,817 447 6,688 Air System CFM per System 0 HVAC EQUIPMENT SELECTION Airflow cfm 0 Wall Furnace Model HWDV080-Panosonic CW-100- 9,549 0 8,000 Airflow(cfm/s ft) 0.00 Airflow cfm/Ton) 0.0 Outside Air(%) 0.0% Total Adjusted System Output 9,549 0 8,000 Outside Air(cfm/s ft) 0.00 (Adjusted for Peak Design conditions) Note:values above given at ARI conditions 1 TIME OF SYSTEM PEAK Aug 3P ml Jan 1 AM HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak) 28 IF 68 IF 105 IF Outside Air -- �- 0 cfm Heating Coil 105 IF ROOM 68 IF 68 IF COOLING SYSTEM PSYCHROMETICS Airstream Tem eratures at Time of Cooling Peak) 88/68 IF 75 162°F 55/541F —-- -- Outside Air 0 cfm Cooling Coil 551 54 OF 48.2% `ROOM 75162 OF 75162°F EnergyPro 5.1 by Energy5oft User Number:6249 Run Code:2014-03-26T16:42:38 ID 14-030210 Page 11 of 12 ROOM LOAD SUMMARY Project Name Date Liem 2nd Unit 3/26/2014 System Name Floor Area HVAC System 383 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Studio Studio 1 177 3,817 447 177 3,817 447 168 6,688 PAGE TOTAL 1 177 3,817 447 168 6,688 TOTAL 1 177 3,8171 447 168 6,688 "Total includes ventilation load for zonal systems. Ener Pro 5.1 by Ener Soft User Number:6249 RunCode:2014-03-26T16:42:38 ID. 14-030210 Pae 12 of 12