Loading...
14070146 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19089 TILSON AVE CONTRACTOR:CONNAMON SOLAR INC PERMIT NO: 14070146 OWNER'S NAME: TAIPING WANG 1550 DELL AVE STE L DATE ISSUED:07/31/2014 OWNER'S PHONE: 4082047589 CAMPBELL,CA 95008 PHONE NO:(408)883-7000 0 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ INSTALLATION OF ROOF MOUNTED SOLAR(27 PANELS) License Class Lic.# 1 (6.9(6.9 KW) Contractor (}v� Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25500 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:37508056.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter C. upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, S costs,and expenses which may accrue against said City in consequence of the `e.�i� granting of this permit. Additionally,the applicant understands and will comply Issued by: Date.! with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. ,---- ' RE-ROOFS: Signature {v Date I i All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that[am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(See,7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous 1 have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: Date: I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. c �' 7a1 -YL ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION I 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 AE CUPERTOPtO (408)777-3228- FAX(408)777-3333•buildin9Lc"1cL!pertino M PRO.I F_C"F ADDRESS ► APN!! f -08' OWNER NAML � PHO 1 E-MAIL j( )lei oa SFRf r ADD FSS CIT ,SIA E,ZIP FAX CON"fA('I NAME BOAr PHO E. �, - DCG E-MAIL r '>1v�rh o�aa: CsH� SIRFI-1 ADDRESS _ Av p CITY ATE, ZIP !1 FAX lv �� ❑OWNER ❑ OWNFR-BUILDGR ❑ OWNER AGEVI' m IIINIRACFOR ❑CONTRAC'rORAGENT ❑ ARCHITECI ❑ENGINEER ❑ DLVF.LOPFR ❑ rENANT CONTRACTO `AMELICEN :NII BER LICE E TYP BUS LIC# r /n6-vL 5) �— COMP 'NAML 5 E-M ^ FAX ianA� C 2 La'(- q_,,— Nr—.Cowk_ STRFI:1 ADI) - J - CIT 'TATF„Z,IP /I � PHONE I port ii tCHI'PECIYFNG PR NAME LICENSE NUMBER f BUS LIC N c. Gf r CUMPA. AM E-MAI FAX SREF'F ADD S ` ('1'Y,Sl'Al'E,ZI �Z'y PHONE s7sLll OY40 in USE OF ❑ SFD Of Duplex ❑ Multi-Family PRO.IF.CTIN WILDL. ND PROJECT IN STRCC'TURE ❑ Coni IllCrCial URBAN INTERFACE AREA ❑ Yes M NI FLOOD ZONE ❑ Yes SOLAR P;NNI.I S ❑ LL.ECrRI('VEHICLE.CFI,4RGING STATION ❑ SOLAR WATER HEATING ❑ OTHER FORSOLAHP,IN".S: NUMBER OF PANELS/UNITS:�fjL 0KILOWAITS: /; TOTAL.VALWT 5 D0 L DFSCRIPIION OF WORK aj - ��ve RECEIVED BY: By my signature below.I certifv to each of the following: I am the property owner or authorized agent to act on the property owner's behalf I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building construction. I aut orize representatives of Cupertino to enter the above-Pentifieq property for inspection purposes. Si nature of A llcanL'A ent. � ,� Date:___ r7 g PP g 1r � � — — — — SUF'Pl_: ENTAL INFORMATION REQUIRED OFFICE USE ONLY OYER-THE-CO(TNTER a ❑ EXPRESS k U m ❑ STANDARD U ❑ LARGE a. ❑ MAJOR Pl'App 2012.doc revised 06.2072 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 19089 Tilson Ave DATE: 07/31/2014 REVIEWED BY: Sean APN: BP#: 0 `VALUATION: $25,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RE USE: PERMIT TYPE: WORK Installation of roof mounted solar 27 anels 6.9 kw SCOPE NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the prelimina information available and are only an estimate. Contact the Dept/or a(ldn'l in o. FEE ITEMS (Fee Resolution II-053 Eff' /."/3) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1� # Alternative Energy System Suppl. PC Fee: E) Reg. Q OT 0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:(j) Reg. Q OT0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 F—F 0 Work Without Permit? 0 Yes E) No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential E) Building or Structure 0 Strong Motion Fee: IBSEISMICR /a�3�$3�� Select an Administrative Item Bldg Stds Commission Fee: IBCBSC Ocl $ye6 To– SUBTOTALS: $4.25 $236.00 TOTAL FEE: Revised: 07/10/2014 PLOT Pl APIu CHECKED BY DATE 2- 2 l — j4 J WORKING CLEARANCES PER NEC 110 SITE NOTES LABEL FOR MAIN SERVICE PANEL DATE 1PER NEC 705 '1 ATTACH. ^THIS ELECTRICAL SYSTEM METHOD ROOF TYPE #OF PANELS PITCH #OF FLOORS IS ALSO SERVED BV A _-_ — PHOTOVOLTAIC SYSTEMFlush Mount Tile 27 1 SIGNSORDIRECTORIESSHALLBEATTACHED PHOTOVOLTAIC SYSTEM TO THE ELECTRIC EQUIPMENT QR LOCATED Scope of Wbrk InsbllaEon ofsontlad ADJACENT TO THE IDENTIFIE D EQUIPMENT rooftop solarpanels" SIGNS SHOULD BE OF SUFFICIENT DURABILITY TABLE OF CONTENTS TO WTHSTAND THE ENVIRONMENT ALL Work sM1all complyurtM1 tM1e 2013 CA PLAQUES SHALL BE PERMANE NTIY ATTACHED Burltlln Cotle 1013 CA Erectr,cel Cotle. Taiping Wang MEANSTO OF EPDXY OR V AMde690antloherapplraM1le PV-1 VICINITY MAP MEANS Of EPDXY SCREWS.OR RIVETS OUTDOOR,SIGNS SHALL BE EITHER METAL OR regwremenls 19089 Tilson Ave PLASTIC WITH ENGRAVED OR MACHINE PRINTED PV-2 SYSTEM LAYOUT LETTERS OR ELECTRO-PHOTO PLATING IN A C O 0 CONTRASTING COLOR TO THE SIGN PV-3 ATTACHMENT METHODS • BACKGROUND SPACE REQUIREMENTS FOR ELECTRIC EAUIPM COMPLY WTH PV-4 ELECTRICAL DIAGRAM PN: 375-08-056 rl 11 PV-5 AMPACITY CALCULATIONS �s.J PVA PLACARD JUL 31 2014 dMMUNlTY DEVELOPMENT UEPAR BYILDING DfViSfON -.CUP r�Tlr� This set of planS-and specifications MUST be kept at the job site during construction. it is unlWul to make arty changes or alte therefrom, w►tbput arations od same, or to deviate pproval from the Building Official. The Stamping of th'rsiplan and s ' ifacations SNCL SGT ' be held to permit or 4-08 an approval of the violation Of any provisions of anY'City Ordinance or State Law. O"F I E 0 BY C q� ATE 7• .�� ..., .,; OF PERMIT NO. x VICINITY MAP 1 AERIAL MAP Taiping Wang REV;g ONS -�eeT Tme IseALE 19089 Tilson Ave / ! DESCRIPTION GATE REV Cupertino,CA 95014 crEc (/ ORIGINAL VERSION 1 722j2.14 1 A VICINITY MAP APN:375-08-056 EDITS n20r2014 5 PV-1 0 m 90 m >:> . . . . Taiping Wang ma, . . - e,er DATE 19089 m Ave Gam.7s14 - \ ssE9��uT 1 P 2 2¥ -0 : . . -Solar Panel 3/16"x 2 1/2" Bolt and Nut " . Mounting ' Clip 3I6"x 1 112" Roof - Bott and Nut Tiles _ QMFTH 0uickMounI._PV- _ - -- Aluminum ' wick Hook - FtOo{ a Univac Rail _ Keys spa. a 2QTY 5/16"x 4" Lag Bolt with -— - 2 2 Penetration - - Sealed with Mastik - Rafter ATTACHMENT PROFILE ATTACHMENT DETAIL SCALE: 1"=1" 1A SCALE: V=6" 1B Taiping Wang DRAM BY CATHY, REVS CAS SnEET me S:ALE 19089 Tilson DESCRiPrlor, DATE REV Cupertino,so 9 Aveve crEc eY ORIGINALVERSICN7/22120U A ATTACHMENT APN:375-08-056 EDTs =�za2e< METHODS PV-3 BRANCH 2:14 MODULES j U BRANCH 1:13 MODULES I � i i • • • — — — — — JUNCTION BOX 20 UTILITY METER A FUSES o 240 Vac 1 PHASE 200 A MAIN DOUBLE POLE BREAKER. DISCONNECT 40 A,240 V EXISTING 200 A RATED MAIN SERVICE PANEL i AWG#8 z I THWN-2 IN 3/4"EMT EXISTING GROUNDING L1=BLACK ELECTRODE L2=RED _ N(NEUTRAL)=WHITE AWG#6 GROUND=GREEN ^_RA-1 B�SlTHYL REV,SICNS SHEET-RE SGGLE Taiping Wang cEscRiFrIoN onrE REv 19089TiIsonAve cRicNaLveRsoN nzvzcia a ELECTRICAL SHEET Cupertino,CA 95014 j o'a 1 nscrzrzc': DIAGRAM PV-4 APN:375-08-056 Module: ICanadian Solar CS6P-255 PHOTOVOLTAIC MODULE SPECIFICATIONS: Module Nominal Voltage: 24 'Model: Canadian Solar C36P-255 Module Isc: _ 8.74 Weight: 44.1 Lbs Module Imp: 8.35 Width 38.7 Inches :Length: 64.5 Inches �.,Mayimum roofload: 2.76 Lbs per square foot AC SYSTEM SPECIFICATIONS 31.9 Lbs perattachment Max AC utputCurrent 24.3 A operaing A�Vctzge 240 V Inverter. jEnphase M215-240 Inverter Voltage: 240 Single or three-phase: 1-phase Current per inverter: 0.9 Number of Inverters: 27 AC Run[HJ: 8o AC Conductor Total Ampacity Calculation(Array to Main Panel) Expected Min ?:of Equip. '., Current- Ampacity 1.25x Inv output Wire Max Voltage Max AC Wire OP, Current-carrying Conductors Per Conduit Conduit Max Ground carrying Before Temp. Packing De-rated =Required Size Power Voltage Drop Run @ Temp(°C] Conduit Type Size Fill Size Wire Size Derating Correction Factor Ampacity, Ampacity, OK? Current Drop[°.] ? Wire Size 50 3 EMT 314" 82% 8 8 55 0.82 1 45.1 30.4 YES 24,3 1.26 YES 95 It Taiping Wang DRAWN BY CaTHY r ReVrs,oras s.;ee*nne oRi��raA�v=,Rsion scn�e 19089 Tilson Ave DESCRIPTIONoA Ol aAMPACITY eV Cupertino,CA 95014 cnec A s,eeT EDITS 30,--Ia e CALCULATIONS PV-5 APN:375-08-056 CD r d a n d 1 J n\c l a r NOTES. BE OF SUFFICIENT DURAB I LRY TO WTHSTAND THE ENVIRONMENT ALL PLAQUES SHALL BE f 1.o d I ICF 6 1 J 61 t PERMANENTLY ATTACHED-SURFACE OF ELECTRICAL EOUIPM ENT BY MEANS OF E-AY SCREWS,OR RIVETS OUTDOOR SIGNS SHALL BE EITHER METAL OR PLASTIC WITH ENGRAVED OR MACHINED PRINTED LETTERS OR ELECTRO-PHOTO PLATING,IN A CONTRASTING COLOR TO THE SIGN IC tEfk:R,eSF�Eilfi/ty(FALNG 6RPNRNG LABELS: via � j u PHOTOVOLTAIC SYSTEM >s � AC(DC)DISCONNECT Bq{ NRATED ORMALCOUTPUT CURRENT 24 AMPS VOLTS NORMAL OPERATING VOLTAGE 240 VOLTS AC _A. I cvxrFs !NL•li;.A i MICMANICrI OAIA ' .ti �ssse-e pph' a! Taiping Wang DRAT^BY CATHY REVISIONS SHEETTITLE SCALE 1 10' 19089 Tilson Ave DEscRIRroN DATE Rev Cupertino,CA 95014 cnec oR,cINALVERSICN T¢vzai4 A PHOTOVOLTAIC aHEE APN:375-08-056 EDITS 7ror2oi4 e PLACARDS PV-6 aaianolar Make The Difference THE BEST IN CLASS Canadian Solar's modules are the best in class in terms of power output and long term reliability. Our meticulous product design and stringent quality control ensure our modules deliver an exceptionally high PV energy yield in live PV system as well as in PVsyst's system simulation.Our accredited in-house PV testing facilities guarantee all module component materials meet the highest quality standards possible. 'Black frame product can be provided upon request. PRODUCT I WARRANTY&INSURANCE PRODUCT I KEY FEATURES Power output t00% Added Value from our li up to 15.85% Excellent module efficiency 97% 90% mited Warranty Staterrlp Industry ao% standartl 5 10 15 20 25 High performance at low irradiance Years above 96.5% 25 Year Industry leading linear power output warranty 10 Year Product warranty on materials and workmanship Positive power tolerance up to 5w Canadian Solar provides 100%non-cancellable,immediate warranty insurance High PTC rating up to 91.88% PRODUCT&MANAGEMENT SYSTEM I CERTIFICATES* IEC 61215/IEC 61730:VDE/CE/MCS/JET/KEMCO/SII/CEC AU/INMETRO/CQC/CGC UL 1703/IEC 61215 performance:CEC listed(US)/FSEC(US Florida) UL 1703:CSA I IEC 61701 ED2:VDE I IEC 62716:TUV I IEC60068-2-68:SGS Anti-glare module surface available PV CYCLE (EU)I UN19177 Reaction to Fire:Class 1 1509001:2008 1 Quality management system ISOTS16949:2009 I The automotive industry quality management system ISO14001:2004 I Standards for environmental management system IP67 junction box QC080000:2012 I The certificate for hazardous substances process management long-term weather endurance OHSAS18001:2007 I International standards for occupational health and safety C BBAV( , cenl u' NRE I u�— Heavy snow load up to 5400pa "Please contact your sales representative for the entire list of certificates applicable to your products tr• CANADIAN SOLAR INC. Eggs Founded in 2001 in Canada,Canadian Solar Inc.,(NASDAQ:CSIQ)is the world's TOP 3 Salt mist,ammonia and blown sand solar power company.As a leading manufacturer of solar modules and PV project resistance,for seaside,farm and developer with about 6 GW of premium quality modules deployed around the world desert environment in the past 13 years,Canadian Solar is one of the most bankable solar companies in Europe, USA, Japan and China. Canadian Solar operates in six continents with customers in over 90 countries and regions. Canadian Solar is committed to providing high quality solar products, solar system solutions and services to customers around the world. 1 ❑� .rr CanadianSolar Make The Difference ELECTRICAL DATA I STC MODULE I ENGINEERING DRAWING Electrical Dat<f CSFs'-2 OP ('5ISP-2550 Rear View Frame Cross Section Nominal Maximum Power (Pmax) 250W 255W Optimum Operating Voltage(Vmp) 30.1 V 30.2 V Optimum Operating Current(Imp) 8.30 A 8.43 A Open Circuit Voltage(Voc) 37.2 V 37.4 V jI i Short Circuit Current(Ise) 8.97 A 9.00 A Module Efficiency 15.54% 15.85% 0 pe rating Te mperatu re -40'C-+85°C + - Maximum System Voltage 1000V(IEC)/1000V(UL)/600V(UL) �I Maximum Series Fuse Rating 15 A Application Classification Class A I Power Tolerance 0'•+5 W ti 'Under Standard Test Conditions(STC)of irradiance of 1000w/m', ( spectrum AM l.S and cell temperatureof 25°C. Lw I'. - •F ,n ELECTRICAL DATA I NOCT Electrical Data C4bP 250P CS6P-2550 Nominal Maximum Power (Pmax) 181 W 185 W Optimum Operating Voltage(Vmp) 27.5 V 27.5 V Optimum Operating Current(Imp) 6,60A 6,71A Open Circuit Voltage(Voc) 34.2 V 34.4 V Short Circuit Current(Isc) 7.19 A 7.29 A CS6P-255P I-V CURVES 'Under Nominal Operating Cell Temperature(NOCT),irradiance of 800 W/m`,spectrum AM 1.5, ambient temperature 20"C,wind speed t m/s. 10 10 MODULE I MECHANICAL DATA z v Sp"clfication Data 7 - . Cell Type , , Poly-crystalline,6inch Cell Arrangement 60(6 x 10) r5 @5 . Dimensions 163$x 982x40mro(64,5 x 38.7 x 1.571n) _ ; Weight 18.5kg(40.8 lbs) u4 u4 I -- FrontCover 3>.2mm tempered glass Frame Material Anodized aluminium alloy ---1000w/m2 4 -5r Junction BOX iP67,3 diodes 2 sooty/mz 2 ---25C I Cable 4mm'((EC)/4mm'&12AWG 1000V(UL1000V)/ 0 600 W/m2 its o 45 C /m2 12AWG(UL60OV),1000mm(650mm is optional) i Connectors MC4 or MC4comparable 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 45 Standard Packaging 24pc5,504kg(quantity and weight per pallet) Wage(v) voltage(v) Module Pieces Per Container 672pcs(40'HQ) TEMPERATURE CHARACTERISTICS Fartner;;ection SpcclFb_a°ion Dala Temperature Coefficient(Pmax) -0.43%/'C Temperature Coefficient(Voc) -0.34%/'C Temperature Coefficient(Isc) 0.065%/,C Nominal Operating Cell Temperature 45±2'C PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation,+96.5%module efficiency from an irradiance of 1000W/m'to 200W/m'(AM 1.5,25°C) As there are d,fffrent cer tifirotion requirements in different rnorkets, products The specification antl keyJeatures des cubed in this Datasheet may deviate slightly and are not quarpn(eed.Due to pn-going innovation,research and pradurt enhancement,Canadian Solar lnc.re es[he right to make any adlvstmenfto the informonon descnhed herein at any time w.thou1--e vleuse nlwvys ohtnin the must recen t version of the datasheel which shall be duly mcorparated into the binding contract made by the parties governing all transactions related to the porhpse andsale of the products desrribed here in Enphase®Microinverters Enphase@M215 t, The E ir��--has ' M'21 w Microinverter with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage®Cable, the Envoy®Communications Gateway'"", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE I M PL E RELIABLE Maximizes energy production No GEC needed for microinverter -More than 1 million hours of testing Minimizes impact of shading, No DC design or string calculation and millions of units shipped dust, and debris required - Industry-leading warranty, up to 25 No single point of system failure - Easy installation with Engage years Cable enphase- ic° E N E R G Y c us Enphase®M215 Microinverter//DATA INPUT DATA(DC)� R M215-60-2LL-S22-IG/S23-IG/S24-IG b Recommended input power(STC) 190-270 W Maximum input DC voltage 48V Peak power tracking voltage 27 V-39 V Operating range 16 V-48 V Min/Max start voltage 22V/48V Max DC short circuit current 15 A Max input current 10A OUTPUT DATA(AC) @208 VAC @240 VAC ............. -Peak output power .225 W....o 225 W . .__.. _. .__..... Rated(continuous)output power 215 W 215 W Nominal output current 1.1 A(A rms at nominal duration) 0.9 A(A rms at nominal duration) Nominal voltage/range 208 V/183-229 V 240 V/211-264 V Nominal frequency/range 60.0/57-61 Hz 60.0/57-61 Hz Extended frequency range' 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25(three phase) 17(single phase) _Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY �CECweighted efficiency, ..�._�,._� 240 VAC 96.5% CEC weighted efficiency,208 VAC 96.5% Peak inverter efficiency 96.5% Static MPPT efficiency(weighted, reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to+65°C Dimensions(WxHxD) 171 mm x 173 mm x 30 mm(without mounting bracket) Weight 1.6 kg(3.4 lbs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 FEATURES r Compatibility Compatible with 60-cell PV modules. Communication Power line Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in NEC 690.35.Equipment ground is provided in the Engage Cable.No additional GEC or ground is required.Ground fault protection(GFP)is integrated into the microinverter. Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance UL1741/IEEE1547,FCC Part 15 Class B,CAN/CSA-C22.2 NO.0-M91, 0.4-04,and 107.1-01 Frequency ranges can be extended beyond nominal if required by the utility To learn more about Enphase Microinverter technology, _ enphase- visit L 3 E N E R G Y 0 2014 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner.