Loading...
14010096CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21840 HERMOSA AVE CONTRACTOR-i1N3 -T(r3E PERMIT NO: 14010096 D OWNER'S NAME: ZHOU YING AND XUE BING ` DATE ISSUED: 01/16/2014 OWNER'S PHONE: 4086533171 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 11 COMMERCIAL 11 License Class �� d Lic. # INSTALL PV SYSTEM ON SFDWL ROOFTOP 18 PANELS, � 4.5 Contractor / &Z,5 GDate j KW, PANEL UPGRADE 125 AMP I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is In full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. Ft Floor Area: Valuation: $18000 performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this APN Number: 35716151.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FR LAST 4 }ALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the /, s /� granting of this permit. Additionally, the applicant understands and will comply Issued by: Date: with all non -point source regu per the Cupertino Municipal Code, Section RE -ROOFS: 9.18. / !/ Signature_ Date __/ � 6 / All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER -BUILDER DECLARATION Signature of Applicant: Date: _ I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure isnot intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self -insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 25505, 25 nd 25534. Section 3700 of the Labor Code, for the performance of the work for which this Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued, I shall hot employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT •BUILDING DIVISION U 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 1� (408) 777-3228 • FAX (408) 777-3333 • building(a)cupertino.org AE PROJECT ADDRESS 2,1,?410 1 p v o APN N 56 OWNER NAME yip Z/w PHONEy E -M AIL i01-';��p (-- �,e/&,,0,•-�s; STREET ADDRESS Ar� CITY, STA E, ZIP FAX CONTACT NAME L / kk L.oJn/ PHONE LL � 7�- 71l �{ 7d� / E-MAIL STREET ADDRESS CITY, STATE. ZIP FAX ❑ OWNER Cl OWNER -BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME 1-4 Ld/A,1 L /rn LICENSE NUMBER 31 6 n p� / LICENSE TYPE C/ D BUS. LIC # COMPANY NAME E-MAIL e Qc-,�iN. ivy t �s FAX STREET ADDRESS CITY, STATE, ZIP s o� Srrs - PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS. LIC H COMPANY NAME E-MAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi -Family FROJ€Cr INDLAND PROJECT IN STRUCTURE. ❑ Commercial URBAN INTER ACE AREA El Yes [I No FLOOD ZONE [I Yes ❑ NO ❑ SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION, ❑ SOLAR WATER HEATING ❑ OTHER - FOR 30LAR PANEL S: NUMBER OF Ri NELS/UNITS: 0 KILOWATTS: TOTAL VALUATIO DESCRIPTION OF WORK .Pv��2 k L��rTv� y l kw RECEIVED BY: By my signature below, 1 certify to each of the following:. -I am theprWeity owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is cgiTect. 1 ha fead.the Description of Work and verify it is accurate. 1 agree to comply with all applicable local c7fru and state laws relating to building fructio a .honze representatives of Cupertino to enter the ab identified p perty or inspection purposes. J-� Signature of Applicant/Agent: Da SUPPLEMENTAL INFORMATION REQUIRED % i' OFFICE USE ONLY ❑ OVER-THE-COUNTER a r F ❑ EXPRESS U U ❑ STANDARD U U ❑ LARGE .¢7 c ❑ MAJOR PVApp 2012.doc revised 06/20//2 Fm���� CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the relimina information available and are only an estimate. Contact the De t or addh 7 info. FEE ITEMS (Fee Resolution 11-053 Eff' 71'1/13) 21840 HERMOSA AVE DATE: 01/16/2014 REVIEWED BY: Mendez lialADDRESS: APN: BP#: C'j 'VALUATION: 1$18,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex USE: /'teub.]nap.Fee: PENTAMATION SOLAR -RES PERMIT TYPE: WORK INSTALL PV SYSTEM ON SFDWL ROOFTOP 18 PANELS 4.5 KW PANEL UPGRADE 125 AMP SCOPE p NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the relimina information available and are only an estimate. Contact the De t or addh 7 info. FEE ITEMS (Fee Resolution 11-053 Eff' 71'1/13) Ph«ub. 1'Icrr, t't�� .�: Elec. Plan Check 0.0 hrs $0.00 MISC ITEMS Elec. Permit Fee: IEPERMIT Oti,er Plumb Imp.Li Other Elea Insp. 0.0 hrs $47.00 cn hisp.Fcc: /'teub.]nap.Fee: Suppl. PC Fee: (F) Reg. ® OT NOTE: This estimate does not include fees due to other Departments (Le. Planning, Public Works, Fire, Sanitary Sewer District, School District, etc.). These fees are based on the relimina information available and are only an estimate. Contact the De t or addh 7 info. FEE ITEMS (Fee Resolution 11-053 Eff' 71'1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 =# $229.00 Alternative Energy System IPHOTOVREs Photovoltaic System Suppl. PC Fee: (F) Reg. ® OT 0.0 hrs $0.00 PME Plan Check: $0.00 125 amps $47.00 Electrical IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee -0 Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $47.00 ('� 11*11ction 1(n: Administrative Fee: ]ADMIN $44.00 O Work Without Permit? 0 Yes (F) No $0.00 Advanced PlanningFee: $0.00 Select a Non -Residential Building or Structure i Travel Documentation Fee: ITPA VDOC $47.00 Strong Motion Fee: IBSEISMICR $1.80 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $140.80 $276.00 TOTAL FEE: 1 $416.80 Revised: 01/15/2014 Roof Mount Solar Array Project Description 21840 Hermosa Avenue, Cupertino, CA 95014 1. Panels: 18 Hanwha HS1_60P6-PB-4-250TW 2. Inverters: 18 Enphase M215-60-2LL-S2x 3. Monitoring system with inverter 4. No battery back-up systems 5. Standard Components include: racking and mounting components, wiring, conduit, and over -current protections 6. All supplied equipment is UL listed. 7. Equipment to be installed per listing or labeling and NEC and CEC 690 requirements. 8. All Metal parts of module frames, equipment, and conductor enclosures will be grounded. 9. All outdoor wiring will be weather rated. 10. Electrical Main Panel, inverter(s) and controller panels will be labeled with warning labels. / 1 • V w,J/ c-,741 3 Gee-. System Size Rating STC Rating 4.5 kW CEC-AC Rating 3.85 kW Elevation System Totals: Point Loading: Panels 720lbs # of Loading Points 48 Racking 200lbs LBS/Load point 22.07 Standoffs (loading points) 60lbs Inverters (if Micro) 79.2lbs Sq.Ft 320.00 Total Array Weight 1059.2lbs lbs/sq ft 3.31 PLOT PLANS. C//K D 9Z Jurisdiction DATE City of Cupertino PNNING DE", 171-1 DATE Site Plan BUILDING DI N - CU X RO 7 TF!s set of plans and specifications ~; ,g construction. It is or alterations on n ,out appro from ,17'6" r,7 eft ' nand spec -:zit r to be an app f any City Ord ,IZ— Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 408=653.3171 :• 3.57• 16 - /S/ Hermosa Avenue #f, OPVICE copV1 21' ST be kill awful to n ie, or to dev the Building (New) External 6 ' 6'z Painted Conduit Run ' 3 Hanwha HSL60P6-PB-4-250TW at t Landscape -oriented ny 65.04" x 39.37" I n HALL NOT the violation or State Law. 2''\ 1 11 1 I— I V6"' \,-2' 14' 6" 38'6" 16'6" 5 Hanwha HSL60P6-PB-4-250TW 10 Hanwha HSL60P6-PB-4-250TW Portrait -oriented Landscape -oriented 65.04" x 39.37" 65.04" x 39.37" Complete Solar Solution COMPLETE SOLAR SOLUTION, INC. 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 nnA p, ATE 650-249-4478 , i 1065 E. Hillsdale Blvd., #308 - Foster Citkk CA 94404 Site Plan (Existing) Main Panel (New) AC Disconnect (New) AC Load Center CUPERTINO 'wilding Departmer :DIFOR CODE COMPLIAN 42'6" '/ :wed BY ..jam.. h4_1 t•t,OT PLAiNn CHECKED BY G DEPT. CA Fire Marshal Setback Requirements in Effect Page: 1 Date: 1/13/2014 I 8' 6" i 171-1 JB m Re CD118'6" 3' 24 6" LB1 FT 2''\ 1 11 1 I— I V6"' \,-2' 14' 6" 38'6" 16'6" 5 Hanwha HSL60P6-PB-4-250TW 10 Hanwha HSL60P6-PB-4-250TW Portrait -oriented Landscape -oriented 65.04" x 39.37" 65.04" x 39.37" Complete Solar Solution COMPLETE SOLAR SOLUTION, INC. 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 nnA p, ATE 650-249-4478 , i 1065 E. Hillsdale Blvd., #308 - Foster Citkk CA 94404 Site Plan (Existing) Main Panel (New) AC Disconnect (New) AC Load Center CUPERTINO 'wilding Departmer :DIFOR CODE COMPLIAN 42'6" '/ :wed BY ..jam.. h4_1 t•t,OT PLAiNn CHECKED BY G DEPT. CA Fire Marshal Setback Requirements in Effect Page: 1 Date: 1/13/2014 Key Notes Solar Panels 18 HSL60P6 PB-4-250TW 2. Inverters: 18 Enphase M215-60-2LL-S2x nilickscrewS Spanish Tile Roof Hook 4. 6' maximum spacing between roof mounts 1. Cveiest Solar tracking System 6. Array Rafters: 2" x 10" @ 24" on center 7. Roof Decking: Plywood 8. Roof Surface: Spanish Concrete Tile 9. Roof Slopes: 20° 10. Azimuths: 10a/b. 90° 10c. 180° (Existing) 2" x 10" @ 24" On Center Rafters Structure and Mounting Hanwha Solar Module Top Mounting Clamp T TEverest Solar Rackin, Quickscrews Spanish Tile Roof 1 Spanish Concrete Tile 2" x 10" @ 24" On Center Array Plywood Decking Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 408.653.3171 Mounting Detail 6" (flush mounted) 5/16" Galvanized Steel Lag Bolt Minimum 2 1/2' Embedment _.� �a:� 20,14 Complete Solar Solution COMPLETE SOLAR SOLUTION, INC. 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 ; B, C-10, ; exp. 6/30/15 COMPLETE 650-249-4478 II 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 2 Date: 1/13/2014 Amperage Calculation Individual Panel (IC)• Vm 30V Imp 8.33A Voc 37AV Isc 8.89A j Pmax 250W Individual Inverter (AC): Vop 240V lop 0.900A AC Amperage Calculations: (9 HSL60P6-PB-4-250TW Branch 1 panels) Vop 240 Volts lop 8.1 Amps x 125% Buffer 10.13 Amps (9 HSL60P6-PB-4-250TW Branch 2 panels) Vop 240 Volts lop 8.1 Amps x 125% Buffer 10.13 Amps General Notes 1. 240V AC wires run from array to main panel breaker. 2. Individual panels inverted from DC to AC with microinverters located under each panel. 3. See Wiring and System Calculations Page for detailed wire & system calculations Single -Line Diagram Note: Railing equipment to use same GEC via approved ground lugs #6 Solid Copper Ground Single Line Drawing 9 HSL60P6-PB-4-250TW + 9 Enphase M215-60-2LL-S2x Microinverters /#12 THWN-2 AC -Bus from Manufacturer (under Array) GEC passing over grounding lug installed on inverter -------------------------------------------------------------------------------- 9 HSL60P6-PB-4-250TW + 9 Enphase M215-60-2LL-S2x Microinverters #12 THWN-2 AC -Bus from Manufacturer (under Array) GEC passing over grounding lug installed on inverter Affixed permanent warning marking or equivalent at overcurrent device: "Warning- inverter output connection- Do not relocate this overcurrent device." Inverter overcurrent devices on the panel board shall be located at the opposite end from the feeder location. 5/8" x 8' grounding rod unless other wise stated or approved by building department (Existing) 200A Main Panel and Meter 0 1 200A G:�, (E) Ground Bus 70A ir-::�k • - - Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 408.653.3171 (E) Main OCPD I 3/4" Metallic Conduit (3) #6 THWN-2 (1) #6 THWN-2 GND (New) 90A AC Disconnect ACD Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 (,O MPI FTE 650-249-4478 *Envoy/Switch Gear/Bridge installed in waterproof (ex. Carlon TM) exterior enclosure With a Locus LGATE 101 (New) 125A AC Load Center --- 15A All Metal parts of module frames, equipment, and conductor enclosures will be grounded. Per NEC and CEC 690 requirements. Irreversible crimp or ground bar in approved junction box i i i i i 3/4" Metallic Conduit (6) #10 THWN-2 (1) #8 THWN-2 GND i Conduit: Runs ' externally along roof surface. Bonded as it enters metallic raceway. Exits with ground bushing or other approved ground clip. i 70A Breaker Relocated from - i 7^0A 15A ----------------------- FOR i 15A -•--•-•-•-•-R�iivtivad By COMPLETE SOLAR SOLUTION, INC. License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 _Main Panel Building Department - i4 CCE COMPLIANCE Page: 3 Date: 1/13/2014 Panel Mfg Model HSL60P6-PB- 4-250TW Hanwha Solar Vmp Imp 30'v Voc 37.4V 37AV Isc 8.89A Pmax 250W Length in 65.04 Width in 39.36 Weight Ibs 40 Inverter Calculations Branch 1 Mfg Enphase Input Data Model 215-60-2LL-S2 Max DC Voltage Peak Power Voltage 45V 22-36V DC Max Input Current 10A Output Data AC Side Branch 1 AC Max Output Power 215 Watts AC Max Output Current 0.9A AC Nominal Voltaa Range, 240V System Specification Calculations Branch 1 DC -Side Local to each individual inverter & module air Operating Current 10A Operating Voltage Maximum System Voltage 22-36V 45V Short Circuit Current Isc 8.89A AC Side Branch 1 Inverter Max Adjusted Max AC Output Current 10.125A Operating AC Volta e 240V AC Side Branch 2 Derated Wir Adjusted Max AC Output Current AC Current 10.125A Operating AC Voltage Temperature 240V C Wire Sizina Calculations Branch 1 Inverter Max Adjusted Adjusted NEC Rated Temperature Number of Number of Conductors Derated Wire Inverter Max Safety Max Current NEC Rated Ambient Derate Number of Conductors Derated Wir Max Run Percent AC Current Factor per CEC Ampacity Temperature Factor @ Conductors in Conduit Ampacity Feet Voltage Drop AMP 690.8 AMP HWN-2 #10 Celsius 90c Per Conduit Derate AMP 90c Factor Factor 8.1 1.25 1 10.125 1 40 1 61-70 0.58 4-6 1 0.8 18.56 85 10.339% C Wire Sizing Calculations Branch 2 Inverter Max Adjusted NEC Rated Temperature Ambient Number of Number of Conductors Derated Wire AC Current Safety Max Current Ampacity Derate Temperature Conductors in Conduit Ampacity Max Run Percent AMP ac Factor per CEC 690.8 AMP THWN-2 #10 Factor @ Celsius Per Conduit Derate AMP Feet Voltage Drop 90c Factor 8.1 1.25 1 10.125 40 61-70 1 0.58 1 4-6 1 0.8 1 18.56 70 1 0.279% DC Wires from panel are connected to inverters via manufacturer's spec, no field installed DC wiring or connectors. AC Wire Size Check, Adjusted Inverter Imp= 1.25* 8.10A= 10.125A< (40A* 0.58 * 0.8) = 18.56A, #10 THWN-2 OK Breaker: 0.90A * 9 Inverters = 8.10A* 1.25 Safety Factor= 10.125A, Use 15A CB. AC Wire Size Check, Adjusted Inverter Imp= 1.25* 8.10A= 10.125A< (40A* 0.58 * 0.8) = 18.56A, #10 THWN-2 OK Breaker: 0.90A * 9 Inverters = 8.10A * 1.25 Safety Factor = 10.125A, Use 15A CB. Labeling: J .all warning sign,. shall he rei nackground with while 318" lettering, all capital tetters, Anal or similar font. Material used for signage must be weather resistant. It is recommended that L txlcm riters Laboratories Marking and Labeling Symem 969 # UL 969) be used as standard to determine weather rating Labels on raceways and other equlpment shall be reflective, weather rest slant. and suitable for the environment, iState Fite Marshal) _l Premises having PV systems shall he identified. The marking (signage) may he placed w ithin the main service disconnect. If the main sen ice disconnect is operable with the service panel closed, the marking should he placed on the outside cover. Marking shall conform to the following: (State Fire Marshal) J \larking is required on all interior and exterior DC conduit, raceways, enclosures, cable assemblies, and junction boxes to alert the Fire Service to avoid cutting them, evm 1() feet.. at turns and above and/or below penetrations and all DC combiner and junction boxes \larking shall conform to the foliow ing, (State Fire Marshal t J Appropriate signage shall he provided to identify die main AIC disconnect for the solar system (State Fire Marshal i. J Where all terminals of the disconnecting meads maybe energized in the open position. a warning stgn shall be mounted on or adjacent to the disconnecting means tCEC 690.17). Total Solar: 0.90A * 18 Inverters = 16.20A * 1.25 Safety Factor = 20.25A �,. CUPERTINO Buildinq DA a �R rtment t I A �, I 2014 w ;n REV'1=VVEr_` FOR CODE COMPLIANCE. Reviewed By "'7str// // � Wiring and System Calculations Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 408.653.3171 Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 - COMPLETE650-249-4478 t.l.' tal.non- COMPLETE SOLAR SOLUTION, INC. License # 961988 1 B, C-iu, C-46 j Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 4 Date: 1/13/2014 Inverter Map eriai ;F: Envoy Location: Communication Level: Ethernet Bridge Installed: Notes: Inverter Map Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 408.653.3171 0� CUPERTINO Su Icing Departent fR, 1 q ^�!�rA/� . JR C Rtvievred �E+�/�.) Complete Solar Solution COMPLETE SOLAR SOLUTION, INC. 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 COrUIPLF; F 650-249-4478 055 E. Hillsdale Blvd., #308 - Foster City, CA 9444/1 Page: 5 Date: 1/13/ZU14 Panel Map Panel Map Ying Zhou 21840 Hermosa Avenue Cupertino, CA 95014 77, 4vo.oar- -3. 3 177 1 Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 Ub1PltTE 650-249-4478 COMPLETE SOLAR SOLUTION, INC. License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 065 E. Hillsdale Blvd.; #308 - Foster City, CA 94404 :1 :RTINO )epartment MPLIANCE h4wl Page: 6 Date: 1% 13/ZU14 [e] enphase The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and Enlighten, Enphase's monitoring and analysis software. Enphase Microinverter Datasheet - Maximum energy production PRODUCTIVE Resilient to dust, debris and shading Performance monitoring per module - System availability greater RELIABLE than 99.8% No single point of system failure - Quick and simple design, installation SMART and management - 24(7 monitoring and analysis SAFE - Low voltage DC - Reduced fire risk M215 — MICROINVEPTEP TECHNICAL DATA •r Recommended input paxer •;STC) Maximum input CC voltage Peak paver tracking voltage Operating range Min./Max. start voltage Max. DC short circuit current Max. input current Maximum output power Nomina I output cu rrent Nominal ,voltage/range Nomina I frequency+'range Extended frequency range Power Factor Maximum units per 20A brand, circuit Maximum output fault current l'iU - 267i J 4W 22/ - 36V 16'J - 36V 26.4V/45V 15A 10.5A 215W 215W 1.10A (arms at nominal duration) 0.9A (arms at nominal duration) 209vn83-229v 240V/211 -264V 60.0/59.3.60.5 Hz 60.0/59.3.60.5 Hz 60.0/59.2-60.6 Hz 60.0/59.2-50.6 Hz >0.95 >0.95 25 (three phase) 17 (single phase) 1.05 Arms, over 3 cycles; 25.2 Apeak, 174ms duration CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency (weighted, reference EN503530) 99.6% Dynamic MPPT efficiency (fast irradiation hanges, reference EN50530) 99.396 Nighttime power consumption 46mW Ambient temperature range -40PC to + 65°C Operating temperature range ;internal; 40°C to + 95°C Dimensions ('HxHxC) 17.3 cm x 16.4 cm x 2.5 cm (6.8" x 6.45" x 1.0")' 'Height 1.6 kg (3.5 lbs) Cooling Natural convection - No fans Enclosure environmental rating Out -door - NEMA 6 'without mounting bracket Compatibility Pairs with most 6C}ceIIP'/modules C PERTINO Communication Power line 8uild ng Department Warranty 25 -year limited warranty i Monitoring Free lifetime monitoring via Enlighten softnw. Compliance °:. E UL1741lIEEE1547, FCC Part 15 Class fi :,:j e .1�I� � � 014 14 CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.E-- ) Enphase Energy, Inc. Pot 1 St street Petaluma, CA 94952 Phone: 877-797-4743 C u5 Fax: 707-763-0784 nfow enphaseeneryy.corn http:f/wNvw.enphase.com Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 COMPLETE Foster i-;EVIEW—MU FOR COD q COMPLIANCE 142-09010 Rev W Revievvea By _/��` 4-1_111 COWLETE SOLAR SOLUTION, INC. License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 7 Date: 1/13/2014 4*01 Key Features Durable and Robust Design: 4000 Pa Wind Load / 7000 Pa Snow Load; Certified to withstand Category 3-4 hurricane winds 2 Predictable Output: Positive power sorting, 0 to +5W 3 Low Light Performance: Excellent performance even under low irradiation Innovative Solution: LIL Certified to t000V for optimized system designs; Anti -reflective glass with self-cleaning hydrophobic layer Harsh Environment: Verified against salt mist and ammonia corrosion `) Tariff Free: High performance Taiwan cells QLiality and Environmental Certificates AbOLIt Hanwha Saler 1509001 quality standards and ISO 14001 environmental standards OHSAS 18001 occupational heal til and safety standards UL 1703 60OV and 10DOV certification CEC listed cul.us CEC LISTED Listed Hanwha Solar aa - -- --- II.. �' nidiivviia Solar Module Data Sheets Hanwha Solar is a vertically integrated manufacturer of photovoltaic modules designed to meet the needs of the global energ y c un sume. • High reliabifiry,guaranteedquality, andexcellentcost-efrlciencydue tovertically integrated production and control of the supply chain • Optimization of product performance and manufacturing processes through a strong commitment to research and development • Global presence throughout Europe, North America and Asia, offering regional technical and sales support HSL 60 1 Poly UL 1:: Electrical Characteristics Electrical Characteristics at Standard Test Conditions ISM Irradiance Levels -- Weight 19i05kq Maximum Power (P.,,j 235W 240 W 245W 250 W 255w Open Circuit Voltage (W) 36BV 37.1V 37.2V 37.4V 37.5V Short Circuit Current (1.) 8.65 A 8.75 A 8.80 A 899 A 8.95 A Voltage at Maximum Power (V,p) 29.1V 29.5V 29.7V 30.0V 30.1V Current at Maximum Power (6,p) BABA 8.14A 815A 834A &48A Module Efficiency (%) 14.5% 14.8% 15.2% 15.5% 15.8% V„ 1•, l•„•,,.aril (,_tried at 5tardad Testin9Candabm 5TC1 dofimd as nradianu+or 1ax7Wi m' at AM 1.5 solar spa r.tr um and a temparrtrxeol [i22C. Modula povvmrdas hove posxiw powarwrting.010 �sW. Measuremem tolerance:+/ 3%(P•,� CeIlSize NunberofCelis(Pieces) Electrical Characteristics at Normal Operating Cell Temperature (NOCT) M .uiidin9 Departmeni )unction Box Protection class IP67 with bypass-clodeOutput LP 25SW t.°,lrinwm PnWer .1' ,,, 1/0W 174W I 18 181W 185W Open Circuit Voltage (V,,) 342V 34.5V 34.6V 348V 34.9V Short Circuit Current (1.) 6.98 A 7.07 A 7.11 A 7.18 A 7.23 A Voltage at Maximum Power(V,npd 263V 26.7V 26.9V 27.1V 27.2V Current at Maximum Power (6.) 6A7A 6.52A 6.62A 6b8A 6.81A ModuleEfficency(%) 13.1% 13.5% 138% 14.0% 14.3% P,n-. Vs. I•. V _ and k.a tested a Normal 0, a ,xlnp Cell lemperature INr1C ri dehnetl as Irradlanue of 80011ihd: 201C. Wind speed I.A. Maasuremerx toles rce..;. r:.. d',.J Foster City, CA 94404 Temperature Characteristics MaxirnumRatings COMNLf:fE 650-249-4478 Normal Operating Cell t:.l., s„r♦ire«- Maximum SystemVdtage 600V or 1000V (UL) Temperature(NOCT) 45C +/-3C Series Fuse Rating 15A Temperature Coefficients of -0.43%/C Serlesfuse Temperature Coefficients ofV - 0.32%/C Maximum Reverse Current rating multiplied Temperature Coefficients of I +0.05%7°C by 1.35 Mechanical Characteristics -j ii IL-lu PCU:ASIW H SL60P6-xxT Cede CMMratlen Cade aortic/lllacf eel 0 WN tUL: 1 Sdv White 4 1000vtW 1W Olackr Wtxit-- TO Wad/dlack xxx represents die power dans Performance at Low Irradiance: The typical efficiency at 200 W/m' In relation to 1000W/m, (25°C, AM 1.5) is at least 96 % of STC efficiency. Venous Irradiance Levels -- Weight 19i05kq r • m N rn-,w•, . Dimensions /636mm x988mm x40 mm -- Weight 19i05kq Frame Aluminum alloy, available in silver or black finish Front Tempered glass Encapsulant EVA Back Cover white or black bac k sheet Cell Technology Polycrystalline (Taiwan)"MPERTINO CeIlSize NunberofCelis(Pieces) 156 mm 156 mm (6 in x6 in) -L 60(6x10) .uiidin9 Departmeni )unction Box Protection class IP67 with bypass-clodeOutput LP Cables Connector Solar table: 4 mm,; length: 1000 min-::.��/" Amphenol H4 even T� MounJrp holes Jramaae hNaa System Design Packaging and StorageEVIEVI L. urt COUt- Operating Temperature - 40 •C to 85 •C Storage Temperature 40°C to 85 C Hail Safety Impact Velocity 25 mm at 23 m/s Packaging Configuration 24 pieces per pallet keviewed By K Fire Safety Classificaton (IEC61730) Class Loading Capacity 672 pieces 0-01 Static Load Wind/Snow 4000PaJ7OOOPa (40ft. FIQ Contairx rl f3rwl01lq 1rolee 8erapn Ml HanWha Solar owrah.5e4arlMe Cu. Ltd Sped atm, -. xrW tbd,aneewlrhwr noUae Rrd♦ne:ori.Werr Complete Solar Solution Page: 8 COMPLETE SOLAR SOLUTION, INC. 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 COMNLf:fE 650-249-4478 Date:1/13%lUl4 t:.l., s„r♦ire«- ii 1065 E. Hillsdale Blvd., #308 -Foster City, CA 9440411 Mour CRIS°RAIL MAIN s_JMF9NENTS labv en M wre m uAnkL M Fnearr Crarq/ eaara CrossRail 48 GossRailMaterial: Alurninkin Length: 161.42" CROSSRAIL ACCE9ORIES Enphase215 Mounting Kit Material Stainless Sorel �'Lidldes: Bolt. Lc-:Viliasher, FlatWasher & f EVEREST SOLAR SYSTEMS CROSSRAIL PiTCHED ROOF SOLUTION Everest Solar Racking Datasheet ASSEMBLY: STEP BY STEP 0 rbJT:f ATTACHMENT IFLASHINC. In Stall the aDPMVr14la roof atlarnmertc: aM tw xrorElnq la them. P.a-_Dl Gcnrs nIre. t N,ifam I¢g 0utknw�m P. C.�SSD�Dan m;urrTS ErrAfa Iha wnarpmof— Ytha roof : b eMng it apolCYta Ws, ragulahkni M9nnr.. ano codas. EnatRa that Inc :V,"rt roof aWlhm aSC PAIrC ars to th1 f4t POStbM 3CCDlding to aV Ot abuc6/al okJYbnf brTM CrmsKalllribm. Matenata Pap Jr ad apDmpnataronlaltYru"i and MSMrg: 0 L-EOCITTORCaJFATTACNMENT Rua try float on top Y Ino rxf anadman wtn t nit, n3 Mg of RA mm fs: the nxf rea Tlghlan I he nakd is I¢g. bat aM rat{ >:A rq to ins ni—it tbr.1 tWru'7apr¢ through We on the bM— Nnpa Y 2. L.h ct MtMatS agw,":IwlasL.ioot.Atxl-- 1.0-na tw' Atl Dart, mm atiS.Yman :,appllar 0 ATTALH CRCSSRAIL as TO THE L -RIOT flare tM •-roasflall on the hkp lbs Y the LFM rarrag the mot3r Insert the T-Gn Mm h the LftY( :Int ano Irtto ilia lateral Chair.) of iha �­Ra11 46. Tan the T2cR:bc la.marhg sure that tris7G:W intik CIS It. ad of in T{y11 t vata:b Pmth;aDpro Dnata:alaodlrq HoXfingi NN onto IlSs T-6011• adjust Ina heaatl of ins rail and fight- in, nut Wth a W.I. ein—r1 Sdfq tCn3li I" tilt :3 Stem. r. a M10. ""' Ma fha tq Y MHa C—all 13 ! lo: atad atw try t:c Y tM Licot. '.V "W that Mc 7•:•:w nark xr rte and Y Ilia. T -b--" Is wrtl]q :QvrW S: 9.1—bte and ragaai this stip. Ni to ttAltna iat.aKJofr vK 1—sn nd a Ityl- mat—k all. IX• m; CN no funfler t1---14.4 Its ,,Rtolnlnittum :aparartl--n li w .tha two IMI, h I IS' to 2. LX coil. Mtanati gJroO:CmISRati AaI, T-60atMlaTar- IodlrlgnuIM10 aRAIL LL1NNECTC1RASiFMUY Align Iha Na: At on* .. to -Z mna iRatl tort. SIM ". P.al Conrado YS to IN rats from Coli algnng the middle of IN Rail ConryaC roar the flare join. Connect try Rall Conneau t: aarh nl ushg T4>C1b ! T.Pclls txak and A •i ItAodLlq nuts. The rail lot! mW no a h Inc rarge of fV Lfom or root atfYMlaY Tlgntating tat": 2S31m11135N.0 blMlflrardWata MYaSSas ragJra O: b! Crnnator is ;Irr:aad as. NtOwara; The CrossRail System is simple and fast toinstail. Mease contact us for further assistance SERVICE -HOTLINE +1 760.301.5300 Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 COMPLETE 650-249-4478 0 ATTACH MCOULESWITH END CLAMPS E—sl Set., sWr . Ertl Garrtpa .iadS—VW MSM Ma unhwsa Ms2 SW Hun for fast, easy ir- •IRYMn TJ i1" frot EIV •]mDs to " Cms-IoA I000n theM"i Sent Na Ira- n. -r':Py as n. putting u; X Ma Dra SW tab titan rWtlng dodWsa 0 x :W;;W Nana, rte' ." end da sp, l_,tJV on dM W blit of arq:1 the rail Ttafe must b atboat 1•-.0 Srlrf' r— ano danp M tn. ad :P tha Ial. . All.rS-4.6. and Poa cn_L:larnp: on sto sn" date -"rig to Mc matufa:tural relnC":. The CL_ raCtor ral a*"ry that .A mourehg hst- nxtkY mflA Irf-AulamaNaYuror arc 1:11.. d! RhO.ac End aamp TayrdSnhg Torpui• I n3la-h 14 Mm. AIltsnat rra4.ara3 E nd Cb.P Sar L -Foot w; T -Bolt 8t Flange Nut 0 End Cap for CrossRail 48 LfcutMateiial. Aluminum �� Material: Glass Fiter Reinforced Polyamid ra�Cl+arr aWrkLS[tinless�teel nc u es: a ex ange F ut to Me lisr,anWin Mc M52 slot H. !n9 Mc ._C.sflatl AB Dy D r/allrq up ori mi Ofafll: tab ttynrxatlng dod.W:e ty i7�ha Rail Connector Set CrossRall 48 Omega Wire Management Clip "F Material�AS5Iu(m1�IIiniump�SSeplice n,,, Mat=fbl:PoP,amid Black I '� des�IlJeSs}azisNiSpli..4T.Bolts&4 Hex Flange ts MutiNt ru3liud Mpya il:mp. `.:a. 0 OPTIONAL: END GAP ASSEMBLY .r Burndy'WEEB Lua B.0 Module End Clamp Set * - fAatartat roil ra] -+.:flan ad Er.;. { a a ri I: a isAlum'r iu a r, js tai, 55 el apt nc a-azern a as er, rpn reg ' Mid Clamp Bumcly WEEB Lug 8.0 Hardware Ma iaistaiT�sSc._1 dr�tuali tggr�a�3, t�,eStur nay WEEB Lug au to Mod ul a P.l id d le C tarn p Set o In Ides:1.1t& Hex Flange Nut att��rld l a s.Alum' ru HHa r 1s ta1����5 Steel etlncJ -assem6le�'�r1.2 oR.'L1as er5p1ra3and Mid Clamp ---- Bu mdy KMC W EES Chp Dark Module End Clamp Set Materia i?,greessgirl to Bend Material Clamp is AlurniniurnHard,nate is Stainless Steel ainp� ,i Ms Pre -assembled W-1 Bolt Washer Spring and the PV Mod ules to theme GcasRail Dark Module. Middle. Clamp Set � at�rij1:�ar�T�IsaIurni�)ru HHar s�rpkrjs in}�sSteel et ns u es assent ed+k2 o t I as r pang and Mid C la rnp f EVEREST SOLAR SYSTEMS CROSSRAIL PiTCHED ROOF SOLUTION Everest Solar Racking Datasheet ASSEMBLY: STEP BY STEP 0 rbJT:f ATTACHMENT IFLASHINC. In Stall the aDPMVr14la roof atlarnmertc: aM tw xrorElnq la them. P.a-_Dl Gcnrs nIre. t N,ifam I¢g 0utknw�m P. C.�SSD�Dan m;urrTS ErrAfa Iha wnarpmof— Ytha roof : b eMng it apolCYta Ws, ragulahkni M9nnr.. ano codas. EnatRa that Inc :V,"rt roof aWlhm aSC PAIrC ars to th1 f4t POStbM 3CCDlding to aV Ot abuc6/al okJYbnf brTM CrmsKalllribm. Matenata Pap Jr ad apDmpnataronlaltYru"i and MSMrg: 0 L-EOCITTORCaJFATTACNMENT Rua try float on top Y Ino rxf anadman wtn t nit, n3 Mg of RA mm fs: the nxf rea Tlghlan I he nakd is I¢g. bat aM rat{ >:A rq to ins ni—it tbr.1 tWru'7apr¢ through We on the bM— Nnpa Y 2. L.h ct MtMatS agw,":IwlasL.ioot.Atxl-- 1.0-na tw' Atl Dart, mm atiS.Yman :,appllar 0 ATTALH CRCSSRAIL as TO THE L -RIOT flare tM •-roasflall on the hkp lbs Y the LFM rarrag the mot3r Insert the T-Gn Mm h the LftY( :Int ano Irtto ilia lateral Chair.) of iha �­Ra11 46. Tan the T2cR:bc la.marhg sure that tris7G:W intik CIS It. ad of in T{y11 t vata:b Pmth;aDpro Dnata:alaodlrq HoXfingi NN onto IlSs T-6011• adjust Ina heaatl of ins rail and fight- in, nut Wth a W.I. ein—r1 Sdfq tCn3li I" tilt :3 Stem. r. a M10. ""' Ma fha tq Y MHa C—all 13 ! lo: atad atw try t:c Y tM Licot. '.V "W that Mc 7•:•:w nark xr rte and Y Ilia. T -b--" Is wrtl]q :QvrW S: 9.1—bte and ragaai this stip. Ni to ttAltna iat.aKJofr vK 1—sn nd a Ityl- mat—k all. IX• m; CN no funfler t1---14.4 Its ,,Rtolnlnittum :aparartl--n li w .tha two IMI, h I IS' to 2. LX coil. Mtanati gJroO:CmISRati AaI, T-60atMlaTar- IodlrlgnuIM10 aRAIL LL1NNECTC1RASiFMUY Align Iha Na: At on* .. to -Z mna iRatl tort. SIM ". P.al Conrado YS to IN rats from Coli algnng the middle of IN Rail ConryaC roar the flare join. Connect try Rall Conneau t: aarh nl ushg T4>C1b ! T.Pclls txak and A •i ItAodLlq nuts. The rail lot! mW no a h Inc rarge of fV Lfom or root atfYMlaY Tlgntating tat": 2S31m11135N.0 blMlflrardWata MYaSSas ragJra O: b! Crnnator is ;Irr:aad as. NtOwara; The CrossRail System is simple and fast toinstail. Mease contact us for further assistance SERVICE -HOTLINE +1 760.301.5300 Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 COMPLETE 650-249-4478 0 ATTACH MCOULESWITH END CLAMPS E—sl Set., sWr . Ertl Garrtpa .iadS—VW MSM Ma unhwsa Ms2 SW Hun for fast, easy ir- •IRYMn TJ i1" frot EIV •]mDs to " Cms-IoA I000n theM"i Sent Na Ira- n. -r':Py as n. putting u; X Ma Dra SW tab titan rWtlng dodWsa 0 x :W;;W Nana, rte' ." end da sp, l_,tJV on dM W blit of arq:1 the rail Ttafe must b atboat 1•-.0 Srlrf' r— ano danp M tn. ad :P tha Ial. . All.rS-4.6. and Poa cn_L:larnp: on sto sn" date -"rig to Mc matufa:tural relnC":. The CL_ raCtor ral a*"ry that .A mourehg hst- nxtkY mflA Irf-AulamaNaYuror arc 1:11.. d! RhO.ac End aamp TayrdSnhg Torpui• I n3la-h 14 Mm. AIltsnat rra4.ara3 E nd Cb.P Sar ACCESSORY ASSEMBLY ATTACH MCC LILFS'A'ITf1 MIDCEE 0 CLAMP$ E—ast sour of �� rsj S N I I. bit. eamdco Mit, Mc krr2 Nut for DSc. • #I - I,Mtim n bn i6 atlrn tM MU tat, U m Ota Cm48 to Me lisr,anWin Mc M52 slot H. !n9 Mc ._C.sflatl AB Dy D r/allrq up ori mi Ofafll: tab ttynrxatlng dod.W:e ty i7�ha Ands rrk.ltlis artl M SRV: tial tamps on TTA mo dub -din cl In to Mi maths --turas tat" k't. Mn ,ry TaC or i rel •e that nay ma hit A C: n.tt kns or (t. an blond! M:9Ji Mo Ct/nC T17tlnrg Torpua ! 0.3 G-, I iii Mm_ MutiNt ru3liud Mpya il:mp. `.:a. 0 OPTIONAL: END GAP ASSEMBLY ELIParlhtlaa phi YlMCro:sR/11 aNCap Mo amd ortha ran fAatartat roil ra] -+.:flan ad Er.;. { ACCESSORY ASSEMBLY Everest Solar Systems, LLC 3809 aoan Ranch Blvd. Suite 111 Oceanside, CA 92056 Tel, + 1360.3015 300 info@everest-solarsystems.com .vww.everest-soiarsystem s ..nMraraa..w ilw .: .. - -.ur rarpua lA•Snue>ass..M.+4uw'd.® Eye pnrw reeii.loAtseMtv¢atesw COMPLETE SOLAR SOLUTION, INC. License # 9619R9 I R C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 9 Date: 11'13i'2014 ENFNASE 21s MCUNTUY K1T - �; `� adMq;;UPERTINO Sbl itatain. to atlCn ma aprns--�� ,.I ,{� ! ph M jie f '49 in,0 Its MC Mli uildirlg DAp�1 Ullent Sbl o Ilia /! IN Dull T. pea �� WatK yp dOCkwta t7 �dgraai. Mau `N I. pL; vtk Ir �.���� � b 2014 OMEGA 0M MANAGEMENTCUP �EVIF1�v-: - —0R. "ODE COMPLIANCE Im all it. O"a 9R¢ oinlt uip"Adip to it* CrcasRal At by pnhcnnp@M�aslayhas a, ttheot dip andft�f•r , J MaC—ItAllY� \`VICYVCU fd fish° /K7 Everest Solar Systems, LLC 3809 aoan Ranch Blvd. Suite 111 Oceanside, CA 92056 Tel, + 1360.3015 300 info@everest-solarsystems.com .vww.everest-soiarsystem s ..nMraraa..w ilw .: .. - -.ur rarpua lA•Snue>ass..M.+4uw'd.® Eye pnrw reeii.loAtseMtv¢atesw COMPLETE SOLAR SOLUTION, INC. License # 9619R9 I R C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 9 Date: 11'13i'2014 ti 9 www quickscrews. com Spanish Style Roof Hooks ' QS# Order 0 Weight STRH9038 20 22 FsTRH9038-1 1 1.1 c= C NQS# Order Oty Weight STRHADJ 10 13 ISTRHADJ-1 1 1 3 rli iirkCrrPws Spanish Tile Root HOOK Datasheet 'Irls AFAVIZIFF APPLIEDVK/kTFr9,AA\LR A EaSOMC GR0aSo ONCe 980 41st Street Tel: (510) 420.8190 Oakland, CA 94608 FAX: (510) 420-8186 e-mail: info@appmateng.com July 25, 2012 Mr. Rick Gentry Project Number 112448C QUICKSCREWS INTERNATIONAL 5830 Las Positas Road Livermore, CA 94551 Subject: Spanish Tile Roof Hook (Part #STRH90) Laboratory Load Testing Dear Mr. Gentry: As requested, Applied Materials & Engineering, Inc. (AME) has completed load -testing Spanish tile roof hook (see Appendix A, Figure 1). The purpose of our testing was to evaluate the tensile and compressive load capacity of the Spanish tile roof hook attached to a 2"x4" Douglas Fir rafter using # 12 Quickscrew (5/16" Ox 3" L T 17 302 SS). SAMPLE DESCRIPTION Mockup samples were delivered to our laboratory on July 6, 2012. Mockup configuration consisted of three 16" long rafters at 7"o.c., screwed to 1/2" OSB sheathing. The Spanish tile roof hook is attached through the OSB into the rafter with two fasteners. TLS I PROCEDI'RES & RESULTS 1. Compressive Load Test A total of three tests were conducted for compressive load capacity on July 14, 2012 using a United Universal testing machine. Samples were rigidly attached to the testing machine and a compressive load was applied to the hook. The samples were loaded in compression at a constant rate of axial deformation of 0.09 in. /min. without shock until the bracket was in contact with the OSB sheathing. maximum deflection at maximum load was recorded. Detailed results are provided in Table L Test setup and typical bracket bending at maximum load are provided in Appendix A. Based on the above testing, the average maximum compression load of the Spanish tile roof hook attached to a2"x4" Douglas Fir rafter using #12 Quickscrew was determined to be 230 Ibf. CUPERTINO I` 2. Tensile Load Test jt iutlding Department A total of three tests were conducted for tensile load capacity on A 12susing a UnitQ0 Un' testing machine. Samples were rigidly attached to the testing mac !. •tensile k�das apbl w2 the hook. The samples were loaded in tension at a constant rate of axial deformation of 0.09 in. /min. without shock until the bracket was bent and the bolt began to puII;tLn T #1�q 'e( tDE COMPLIANCE maximum load was recorded. Detailed results are provided in Table 11. Reviewed By _ sew i4'01 Page 1 of 8 APPLIED Jb1UE- K21 A- E'' 2 mmxe' [n' Complete Solar Solution COMPLETE SOLAR SOLUTION, INC. Page: 10 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 COMPLETE Foster ;;� Date: 1/13/2014 iW) L. riniSdaie blvu., 43032'r..�icr U':`'p_ !-A Qad('i:i' Mr. Rick Genn QUIC'KSCREWS INTERNATIONAI.. Spanish Tile Roof Hoak July 25. 2012 Project Number 1124480 Test setup and typical bracket bending at maximum load are provided in Appendix A. Based on the above testing, the average maximum tensile load of the Spanish the hook attached to a 2"x4" Douglas Fir rafter using #12 Quickscrew was determined to be 1336 Ibf, 3, Specific Gra%ity of Wood The specific gra% it,. and moisture content of the lumber irafteo were tested in accordance with ASTb4 13239-5—Method A (oven -dry 1 and was determined to be 0.457 and 12.9 %. respectively. I I' you have any questions regarding the above, please do not hesitate to call the undersigned, Respectfully Submitted. APPLIED MATERIALS ENGINEERING, INC. Revimed Bv: Mtyar Armen l' "tion. h.l).. I' ! Laboratory Manager Principal Page 2 of 8 QuickScrews Spanish Tile Roof Hook Datasheet Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 COMPLETE Foster l CUPERTINO k "luildinq Denartment t JAN 16 2014 �EVlEv`vcf. =OFZ CODE CO(v PUANCL- Reviewed By COMPLETE SOLAR SOLUTION, INC. License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 Page: 11 Date: 1/13/2014 Introducing SOLARLOK Grounding Bolt These bolts are designed for solar module grounding applications using solid copper uninsulated 6 AWG to 12 AWG wire, or stranded copper uninsuleted 6 AWG to 10 AWG (7 or 19 strands) wire. The grounding msembty consists of a wire bolt (wire sbt on one end and threaded post on the other), wire binding hex nut and mounting lock washer nut. The grounding assembly is used with metal -framed photovoltaic (solar) panels and related products that require grounding for ofetyreasons. TE Connectivity I t 5olarLok vrounding Bolt Datasheet TE Technical Support Center fit~: te.com/heip USA: -1 (800) 522 6752 Canada -1(905) 475.6222 t4wico •52(0)55-006.0800 Latin/5, AnnMka -54 (0)11-4733-2200 Ci mdnY: +49(0)6251-133-1999 UK .44 (0) 800-267666 Francs: •33 (0)1.3420 -WAS NeUNedaands: -31(0)73-6246-9" China: -66(0)400-WO-6015 te.conviolar # 200 61a BYdrallc. C--- . FE C•r. —Y"a tl.tR11n ' AY RW.. A.—d. 6-t 1M.% 6 CIS PCF O> WO SOLARL Ot, T1 Ca on ft r[ —i NIY OM6 &WTE Q•ep .w RrMom.aa.. Odw loo-, podu[t lndhv cdM.n; nans mdhrbe Ya01f/W1a at "t no—W. grrn<r� Complete Solar Solution 1065 E. Hillsdale, Suite 308 Foster City, CA 94404 COMPLETE rITn -)An AA-ro APPLICATIONS Solar panels and related phobovoltaic products requre grounding per the National Electric Code (NEC Article 690.34). These applications include, but are not limited to electrical grounding of solar modules and solar roof tiles. ELECTRICAL Start Term Current Test (UL 467) 6 AWG = 1530A (6 seconds). 8 AWG = 1180A (4 seconds) 10 AWG = 750A(4 seconds). 12 AWG = 470A(4 seconds) MECHANICAL Secureness Test (UL 48GA-8) : 6 AWG = 18 lbs (30 minutes). 8 AWG = 81bs (30 minutes) 10 AWG = Sibs (30 minutes), 12 AWG = S lbs (30 minutes) Pub out Test (UL 486A-19) : 6 AWG = 100 lbs (1 minute), 8 AWG = 9D lbs (I minute) 10 AWG = 80 lbs 0 minute). 12 AWG = 70 lbs 0 minute) APPLICABLE WIRE SIZES Uninsulated Coper Wire Wire 9- Solid Sl randad 6 AWG Yes t or 19 strands 6 Aw , 7:.r P A-1, IOAWG Y -s tr.nd 12 AWG Yes r p MATERIALS Connector and Hardware: Stainless Steel (Passivated) PRODUCT OFFERING PART NUMBER THREAD DIM 'Ar 2OSS729-1 88.32 UNC .390 2106651-1 610.32 UNF 1.700 APPLICATION TOOLING Starndard he/ socket or wrenches with torque driver. Top View Side View Bottom View A .1 RTI Edge fcat ur, _ JAN 1 2014 rE eviewe(7 By _� �'T�r{a/ntcrrvny . .., .�wM%�/d-'b�waecc�i.`.b.x arwnl6cw a PW�IN IvrrsMw �s Oa�!t:« • vfa iaMY WeP..a..1+fi.a•.�.. N•bn.r+C/..lr.. lw.a.M•Alp bA n.e �. .vwaMalVNMlursvb V.NdllMln�wa..fH<MKQMbrelMMeIMNI•MreMw.sr+ .. / ,.Ma+3i/<M.c•i M f a1W w sigl.aM.t..tt GI..M /E AYp1 aaf aYA.M a<./ape W.IMs COMPLETE SOLAR SOLUTION, !NC. License # 961988 1 B, C-10, C-46 I Exp. 6/30/15 1065 E. Hillsdale Blvd., #308 - Foster City, CA 94404 VacA• 7 7 r1_L-- A /A. 1.1 . UOLC. L/ 1J/ LV1'+