13100032 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 19733 WINTERGREEN DR CONTRACTOR:IBS USA INC PERMIT NO: 13100032
OWNER'S NAME: RICHARD CHANG 418 RAMSELL ST DATE ISSUED:01/06/2014
OWNER'S PHONE: 4085824276 SAN FRANCISCO,CA 94132 PHONE NO:(415)793-3889
❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑
/ ADD 316 SQ FT TO REAR SFDWL INCLUDES NEW
License Class �L_ Lic.# 3 5 I S b BEDROOM,
CLOSET,& BATHROOM.DEMOLISH OF(E)REAR WOOD
Contractor�C '['j� (,�rt� Date1 TRELLIS,REMOVE(E)PATIO SLIDING DOOR FROM
I hereby affirm that I am licensed under the provisions of Chapter 9 FAMILY
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$71000
1 have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
APN Number:36909024.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct. 1 agree to comply with all city and county ordinances and state laws relating WIT S 6I'—PRMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 180 DA ROM LAST CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally,the applicant understands and will comply Issued by: Date:
with all non-point source regulations per the Cupertino Municipal Code,Section
9..18.
RE-ROOFS:
Signature Date !' ! All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date:
the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,25533,and 25534. 1 will
I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District 1
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this Date:
permit is issued. . ,�t4�
Owner or authorized agent:
I certify that in the performance of the work for which this permit is issued,I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked, work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that I have read this application and state that the above information is
correct.1 agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18.
Signature Date
CONSTRUCTION PERMIT APPLICATION O
COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION VO
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 /�_`
CUP'ERTINO (408)777-3228•FAX(408)777-3333•building(@cui)ertino.org �rJ
❑NEW CONSTRUCTION ® ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT fl
PROJECT ADDRESS 19733 WINTERGREEN DR AP"" 369-09-024
OWNER"AME RICHARD CHANG PHONE 408-582-4276 E-MAIL richardlcchang@gmail.com
STREET ADDRESS 19733 WINTERGREEN DR CITY, STATE,ZIP CUPERTINO CA FAX N/A
CONTACT NAME JUAN CARLOS NAVARRO PHO"E408-205-9812 EMAIL jcnavarro@att.net
STREET ADDRESS 1734 Winston St CITY,STATE,ZIP San Jose, CA FAX408-459-1619
❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT M ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT
CONTRACTOR NAME TBD LICENSE NUMBER LICENSE TYPE BUS.LIC H
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
ARCHITECr/ENGINEERNAME JOSE FERNANDEZ7 LICENSE NUMBER C76349 BUS.LIC"408-512-8400
COMPANY NAME JF Consulting E-MAIL jfplans@gmail.com FAX
STREET ADDRESS 2915 Macintyre Dr# 104 CITY,STATE,ZIP San Jose, CA 7PHONE408-512-8400
DESCRIPTION OF WORK Add a new bedroom, bathroom and redwood deck to the back of the house 3 r�
EXISTING USE PROPOSED USE CONSTR TYPE H STORIES
USE TYPE OCC. SQ.FT. VALUATION($)
SF SF VN 2
EXIST2,295 ARENEW FLOOR 2,61 DARE O 0 TNITEMOTAAREA 2,611
BATHROOM KITCHEN OTHER
REMODEL AREA 0 REMODEL AREA O REMODEL AREA 0
P C AREA D K AREA I TOTAL DEC-1ORC.AREA GARAGE AREA: DETACH
28 N100 SF 128 ATTACH
DWELLING UMTS. 1 IS ASECOND UNIT nYES SECONDSTORY RYES
BEING ADDED. 11°��lf NO ADDITION. WOfINO
PRE-APPLICATION YES IF YES,PROVIDE COPY OF IS THE BL CAN YES Y; %l TOTAI,VAT I i eTinni
PLANNING APPL k NO PLANNING APPROVAL LETTER EICHLE OMEt NO I
By my signature below,I certify to each of the following: /ame property owner or authoriz erHo Con the props owner's behalf. I have read this
application and the information I have prov' ed is correct. read the Description of Work and verify it Accurate. I e to comply with all applicable local
ordinances and state laws relating to buildi g construction. rize representatives of Cupertino to enter the afiove-iderrti led property for inspection purposes.
Signature of Applicant/Agent: Date: October 03, 2013
SUPPLEMENTAL IN RMATION REQUIRED PLANCHECKTYPE ROUTING SLIP
New SFD or Multifamily dwellings: Apply for demolition permit for ❑ OVER-TRE-COUNTER ❑ BUILDING PLAN REVIEW
existing building(s). Demolition permit is required prior to issuance of building
permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW
Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS
form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT
_Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT
submittal of Building Permit application.
❑ ENVIRONMENTAL HEALTH
BldgApp_201 I.doC revised 06/21/11
CITY OF CUPERTINO
FEE ESTIMATOR- BUILDING DIVISION
ADDRESS: 19733 WINTERGREEN DR DATE: 10/03/2013 REVIEWED BY: MELISSA
APN: 369 09 024 BP#: *VALUATION: $71,000
*PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition
PRIMARY SFD or Duplex 2nd Unit? 0 Yes QNo PENTAMATION 1 R3SFDADD
USE: OTC. Q Yes 0 No PERMIT TYPE:
WORK ADD 316 S.F. TO REAR SFD. CONSTRUCT N 100 S.F. DECK.
SCOPE
OCCUPANCY TYPE: TYPE OF FLR AREA PC FEES PC FEE ID BP FEES BP FEE ID
CONSTR. s.f.
R-3 (Custom) II-Bj11-B,IV,V-B 316 $1,579.00 IADDPLCK $1,284.00 IADDINSP
TOTALS: 316 $1,579.00 $1,284.00
MECH,HOURLY Q Yes O No PLUMB,HOURLY Yes Q No ELEC,HOURLY Q Yes Q No
f c:fr. Plan Check Plumb. Plan Check I _
Fy �cft, Plumb. Permit F"�-. ,r.Pc>rrnir Fee:
OtberAfech. Insp, Oilier Plumb Insp. ED
01her F.,lec.Lrzsp
Alech-Insp.Fee: Plumb. Irish. Fee: Elec.Insp.Fee:
NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works, Fire,Sanitary Sewer District,School
District etc). Thesefees are based on the prefimina information available and are on an estimate. Contact the De t or addn'l info.
FEE ITEMS wee Resolulion 11-053 E. 7/1/13) FEE QTY/FEE MISC ITEMS
Plan Check Fee: $1,579.00 = # Deck/Deck Railing
Suppl, PC Fee: O Reg. Q OT 0.0 hrs $0.00 $976.00 /DECKWOOD Deck&Deck Railing
PME Plan Check: $0.00
Permit Fee: $1,284.00
Suppl. Insp. Fee:Q Reg. Q OT F0.0 hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
<';'onstruction Tax:
,ldrninistrative Fee: 0
Work Without Permit? Yes Q No $0.00 0
Advanced Planning Fee: IPLLONGR $44.24 Select a Non-Residential 0
1 ravel Documentation Fees: Building or Structure 0
Strong Motion Fee: IBSEISMICR $7.10 Select an Administrative Item
Bldg Stds Commission Fee: /BCBSC $3.00
SUBTOTALS: $2,917.34 $976.00 TOTAL FEE: $3,893.34
Revised: 08/01/2013
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Richard Chang
19733 Wintergreen Drive
Cupertino, CA 95014
Project Designer:
D-Cube Studio ,
1734 Winston Street
San Jose, California
408-205-9812
Report Prepared by:
Rick Rocklewitz
NRG Compliance, Inc
PO Box 3777
Santa Rosa, California 95402
707-237-6957 "
N' ':,:: COMPLIANCE, INC.I
Job Number: (
09221301 QQ �J
T 3?013
Date:
9/22/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report.This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC—www.energysoft.com.
Ener Pro 5.1 by EnergySoft User Number:5581 RunCode:2013-09-22719:55:52 0:09221301
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R Certificate of Compliance 3
Form MF-1 R Mandatory Measures Summary 10
i
EnergyPro 5.1 by EnergySofl Job Number: ID:09221301 User Number:5581
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
Richard Chang ❑ Multi Family ® Existing+Addition/Alteration 9/2212013
Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories
19733 Wintergreen Drive Cupertino CA Climate Zone 04 2,612 316 2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity ( Features see Part 2 of 5) Status
Floor Wood Framed w/Crawl Space None 432 Existing
Wall Wood Framed None 1,865 Existing
Door Opaque Door None 50 Existing
Roof Wood Framed Attic R-11 1,606 Existing
Slab Unheated Slab-on-Grade None 1,014 Perim=158' Existing
Wall Wood Framed R-13 345 New
Roof Wood Framed Attic R-30 250 New
Slab Unheated Slab-on-Grade None 316 Perim=51' New
FENESTRATION U- Exterior
Orientation Area( Factor SHGC Overhang Sidefins Shades Status
Front(S) 82.0 0.550 0.67 none none Bug Screen Existing
Left(lM 28.0 0.550 0.67 none none Bug Screen Existing
Left(lM 27.0 0.390 0.37 none none Bug Screen New
Rear(N) 78.0 0.550 0.67 none none Bug Screen Existing
Rear(N) 92.6 0.390 0.37 none none Bug Screen New
Right(E) 12.0 0.550 0.67 none none Bug Screen Existing
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 78%AFUE Split Air Conditioner 11.0 SEER Setback Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
HVAC System Ducted Ducted Attic, Ceiling Ins,vented 4.2 Existing
WATER HEATING
Qty- Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnergySoft User Number:5581 RunCode:2013-09-22T19:55:52 ID:09221301 Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
Richard Chang ❑ Multi Family ® Existing+Addition/Alteration 9/22/2013
Project Address California Energy Climate Zone Total Cond. Floor Area Addition #of Stories
19733 Wintergreen Drive Cupertino CA Climate Zone 04 2,612 316 2
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
Floor Wood Framed w/o Crawl Space None 52 Existing
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
Ener Pro 5.1 by EnefgySoft User Number:5581 Run Code:2013-09-22719:55:52 0:09221301 Page 4 of 12
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF-1 R
Project Name Building Type ® Single Family ❑Addition Alone TDateRichard Chang ❑ Multi Family ®Existing+Addition/Alteration12212013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist.These items require special written
justification and documentation,and special verification to be used with the performance approach.The enforcement agency
determines the adequacy of the justification,and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF-4R form for each of the measures listed below for final to be given.
Enerq yPro 5.1 by Ener Soft User Number.,5581 RunCode:2013-09-22719:55:52 0:09221301 Page 5 of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
Richard Chang ❑ Multi Family m Existing+Addition/Alteration 9/22/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 54.20 54.70 -0.50
Space Cooling 18.18 17.13 1.06
Fans 10.11 9.93 0.18
Domestic Hot Water 15.42 15.42 0.00
Pumps 0.00 0.00 0.00
Totals 97.91 97.17 0.74
Percent Better Than Standard: 0.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (S) 180 deg Ext.Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (S) 576 82
Fuel Available at Site: Natural Gas (W) 714 55
Raised Floor Area: 484 (N) 576 171
Slab on Grade Area: 1,330 (E) 714 12
Average Ceiling Height: 8.0 Roof 1,856 0
Fenestration Average U-Factor: 0.49 TOTAL: 320
Average SHGC: 0.56 Fenestration/CFA Ratio: 12.2%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company NRG Compliance, Inc
Address PO Box 3777 Name Rick Rocklewitz , 9722/2013
City/State/ZipCity/State/Zip Santa Rosa, California 95402 Phone 707-237-6957 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelop ealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company D-Cube Studio
Address 1734 Winston Street Name D-Cube Studio
City/State/Zip San Jose, California Phone 408-205-9812 Sig d License# Date
EnerqyPro 5.1 by Ener Soft User Number:5581 RunCode:2013-09-22T19:55:52 0:09221301 Page 6 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name Building Type m Single Family ❑Addition Alone Date
Richard Chang ❑Multi Family m Existing+Addition/Alteration 912212013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame I Interior Frame Azm Tilt Status 4 Location/Comments
Floor 432 0.097 None 0 180 Existing 4.4.1-A1 First Floor
Wall 308 0.356 None 180 90 Existing 4.3.1-A1 First Floor
Door 50 0.500 None 180 90 Existing 4.5.1-A4 First Floor
Wall 237 0.356 None 270 90 Existing 4.3.1-A1 First Floor
Wall 148 0.356 None 0 90 Existing 4.3.1-A1 First Floor
Wall 282 0.356 None 90 90 Existing 4.3.1-A1 First Floor
Roof 756 0.079 R-11 180 18 Existing 4.2.1-A2 First Floor
Slab 1,014 0.730 None 0 180 Existing 4.4.7-A1 First Floor
Wall 114 0.102 R-13 270 90 New 4.3.1-A3 First Floor
Wall 117 0.102 R-13 0 90 New 4.3.1-A3 First Floor
Wall 114 0.102 R-13 90 90 New 4.3.1-A3 First Floor
Roof 250 0.031 R-30 0 18 New 4.2.1-A20 First Floor
Slab 316 0.730 None 0 180 New 4.4.7-A1 First Floor
Floor 52 0.238 None 0 180 Existing 4.4.2-A1 Second Floor
Wall 136 0.356 None 180 90 Exi ting 4.3.1-A1 Second Floor
Wall 308 0.356 None 2701 90 1 Existing 4.3.1-A1 Second Floor
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor SHGC2 Azm Status Glazing Type Location/Comments
1 Window 42.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear First Floor
2 Window 24.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear First Floor
3 Window 27.0 0.390 NFRC 0.37 NFRC 270 New Dual Pane Vinyl LowE First Floor
4 Window 42.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear First Floor
5 Window 33.3 0.390 NFRC 0.37 NFRC 0 New I Dual Pane Vinyl LowE First Floor
6 Window 6.0 0.550 1 Default 0.67 Default 90 Existing Double Non Metal Clear First Floor
7 Window 59.3 0.390 NFRC 0.37 NFRC 0 New Dual Pane Vinyl LowE First Floor
8 Window 40.0 0.550 Default 0.67 Default 180 Existing Double Non Metal Clear Second Floor
9 Window 4.0 0.550 Default 0.67 Default 270 Existing Double Non Metal Clear Second Floor
10 Window 36.0 0.550 Default 0.67 Default 0 Existing Double Non Metal Clear Second Floor
11 Window 6.0 0.550 Default 0.67 Default 90 Existing Double Non Metal Clear Second Floor
(1) U-Factor Type: 1 16-A=Default Table from Standards,NFRC=Labeled Value
2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H t TWd Len H t LExt RExt Dist Len H t Dist Len H t
1 Bug Screen 0.76
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
5 Bug Screen 0.76
6 _Bug Screen 0.76
7 Bug Screen 0.76
8 Bug Screen 0.76
9_Bug Screen 0.76
10 Bug Screen 0.76
11 Bug Screen 0.76
Ener Pro 5.1 by Ener Soft User Number:5581 Run Code:2013-09-22T19:55:52 ID:09221301 Page 7 of 12
CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF-1 R
Project Name Building Type ®Single Family 0 Addition Alone Date
Richard Chang 11 Multi Family 10 Existing+Addition/Alteration 912212013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
wall 140 0.356 None 0 90 Existing 4.3.1-A1 Second Floor
wall 306 0.356 None 90 90 Existing 4.3.1-A1 Second Floor
Roof 850 0.079 R-11 180 18 Existing 4.2.1-A2 Second Floor
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor SHGC Azm Status Glazing Type Location/Comments
(1) U-Factor Type: 116-A=Default Table from Standards,NFRC=Labeled Value
2 SHGC Type: 116-B=Default Table from Standards,NFRC=Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hang Left Fin Right Fin
ID Exterior Shade Type SHGC H tWd Len Hat LExt RExt Dist Len H t Dist Len Hq t
Ener Pro 5.1 by Ener Soft User Number:5581 RunCode:2013-09-22719:55:52 0:09221301 Page 8 of L2J
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF-1 R
Project Name Building Type 0 Single Family ❑ Addition Alone Date
Richard Chang ❑Multi Family m Existing+Addition/Alteration 912212013
BUILDING ZONE INFORMATION
Floor Area
System Name Zone Name New Existing Altered Removed Volume Year Built
HVAC System Existing 1,446 11,564 1967
Addition 316 2,528
Existing 850 6,802 1967
Totals 1 3161 8501 1,446 01 1
HVAC SYSTEMS
System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System 1 Central Furnace 78%AFUE Split Air Conditioner 11.0 SEER Setback Existing
HVAC DISTRIBUTION
Duct Ducts
System Name Heating Coolin Duct Location R-Value Tested? Status
HVAC System Ducted Ducted Attic,Ceiling Ins,vented 4.2 ❑ Existing
o
WATER HEATING SYSTEMS
Ext.
Rated Tank Energy Standby Tank
Input Cap. Factor Loss or Insul. R-
S stem Name Qty. Type Distribution Btuh al or RE Pilot Value Status
Standard Gas 50 gal or Le 1 Small Gas No Pipe Insulation 40,000 50 0.58 n/a n/a Existing
MULTI-FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING
Hot Water Piping Length
ft 0
0
N
o N Pipe Pipe Insul.
Control Qty- HP Plenum Outside Buried ¢c System Name Len th Diameter Thick.
Ener Pro 5.1 by EnergySoft User Number:5581 RunCode:2013-09-22T19:55:52 0:09221301 Pae 9 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF-1 R
Project Name Date
Richard Chang 9/22/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF-1 R,CF-1 R-ADD, or CF-
1 R-ALT Form) shall supersede the items marked with an asterisk(') below.This Mandatory Measures Summary shall be incorporated
into the permit documents,and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF-1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products(except field-fabricated windows) have a label listing the certified U-Factor,certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111(a).
117: Exterior doors and windows are weather-stripped;all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF-611 Form.
§118(i):The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of§118(i)when the
installation of a Cool Roof is specified on the CF-1 R Form.
*§1 50 a :Minimum R-19 insulation in wood-frame ceiling orequivalent U-factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R-Value.
150(c): Minimum R-13 insulation in wood-frame wall orequivalent U-factor.
150(d):Minimum R-13 insulation in raised wood-frame floor orequivalent U-factor.
150(f):Air retarding wrap is tested, labeled,and installed according to ASTM E1677-95 2000 when specified on the CF-1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1):Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%;water vapor permeance
rate is no qreater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory-built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory-built fireplaces have a combustion outside air intake,which is at least six square inches in area and is
equipped with a with a readily accessible,operable,and tight-fitting damper and or a combustion-air control device.
§150(e)2:Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket,when that indoor air is vented to the
outside of the building,are prohibited.
Space Conditioning,Water Heating and Plumbing System Measures:
§110-§113:HVAC equipment,water heaters,showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5:Water heating recirculation loops serving multiple dwelling units and High-Rise residential occupancies meet the air release
valve, backflow prevention,pump isolation valve,and recirculation loop connection requirements of§113(c)5.
§115:Continuously burning pilot lights are prohibited for natural gas:fan-type central furnaces,household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt),and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks,such as storage tanks or backup tanks for solar water-heating system,or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculating systems,and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§150(j)2: Cooling system piping(suction,chilled water,or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems>15 psi, meets the requirements of Standards Table
123-A.
150(i)3A: Insulation is protected from damage, including that due to sunlight,moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150 4:Solar water-heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number:5581 RunCode:2013-09-22T19:55:52 0:09221301 Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF-1 R
Project Name Date
Richard Chang 9/22/2013
§150(m)1:All air-distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601,602,603,604,605 and Standard 6-5;supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space.Openings shall be sealed with mastic,tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 181 A,or LIL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch,the combination of mastic and either mesh or tape shall be used
§150(m)1:Building cavities,support platforms for air handlers,and plenums defined or constructed with materials other than sealed
sheet metal,duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D:Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8:Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight,moisture,equipment maintenance,and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o):All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings.Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a):Any pool or spa heating system shall be certified to have:a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater;a permanent weatherproof plate or card with operating instructions;and
shall not use electric resistance heating ora pilot light.
§114(b)1:Any pool or spa heating equipment shall be installed with at least 36"of pipe between filter and heater, or dedicated suction
and return lines,or built-up connections for future solar heating.
114(b)2:Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water,and a time switch that will allow all pumps to be set or
orocrammed to run only during off-peak electric demand periods.
150 : Residential pool systems or equipment meet the pump sizing,flow rate,piping,filters,and valve requirements of§150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by§150(k)2.
150(k)3:The wattage of permanently installed luminaires shall be determined asspecified by§130(d).
§150(k)4:Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line-voltage socket or line-
voltage lamp holder;OR shall be rated to consume no more than five watts of power as determined by§130(d), and shall not contain a
medium screw-base socket.
150(k)6:Lighting integral to exhaust fans, in rooms other than kitchens,shall meet the applicable requirements of§150(k).
150(k)7:All switching devices and controls shall meet the requirements of§150(k)7.
§150(k)8:A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50%high efficacy requirement when:all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor,dimmer,energy management system (EMCS),or a multi-scene programmable control system;and all permanently installed
luminaries in garages, laundry rooms,closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
§150(k)9:Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoff User Number:5581 RunCode:2013-09-22T19:55:52 0:09221301 Page 11 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-'I R
Project Name Date
Richard Chang 9/22/2013
§150(k)10:Permanently installed luminaires in bathrooms,attached and detached garages, laundry rooms,closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of§119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)11:Permanently installed luminaires located in rooms or areas other than in kitchens,bathrooms,garages, laundry rooms,
closets,and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of§119,or by a manual-
on occupant sensor that complies with the applicable requirements of§119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not re uired to comply with§150 k 11.
§150(k)l2:Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact(IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory;and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies,and porches,which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls:a photocontrol not having an override or bypass switch that disables the photocontrol;OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock;OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2:Outdoor
luminaires used to comply with Exceptionl to§150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool,water features,or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148;OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to§130 d .
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147.Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134,and 146.
§150(k)16:Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number:5581 RunCode:2013-09-22719:55:52 0:09221301 Page 12 of 12