Loading...
B-2017-1816 CITY OF CUPERTINO BUILDING PERMIT - BUILDING ADDRESS: CONTRACTOR: PERMIT NO:B-2017-1816 10285 COLBY AVE CUPERTINO,CA 95014-2421(316 29 028) HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION SAN JOSE,CA 95117 . OWNER'S NAME: MUKHERJEE DEBANJANAND DEEPANJANATRUSTEE DATE ISSUED: 10/24/2017 • OWNER'S PHONE:408-802-2103 PHONE NO:(408)489-9273 LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: License Class C-46 Lic.#960376 Contractor HIGHLIGHT SOLAR INC A CALIFORNIA CORPORATION Date X BLDG _ELECT _PLUMB • 04/30/2019 _MECH X RESIDENTIAL_COMMERCIAL • I hereby affirm that I am licensed under-the provisions of Chapter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my JOB DESCRIPTION: license is in full force and effect.' (N) 13 PANEL ROOF MOUNTED PV SYSTEM(4.29 KW) I hereby affirm under penalty of perjury one of the following two declarations: ' 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance,of the work for which this permit is issued. ti 00010.I have and will maintain Worker's Compensation Insurance,as provided for by ' Section 3700 of the Labor Code,for the performance of the work for which this Sq.Ft Floor Area: Valuation:$14520.00 permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above APN Number: Occupancy Type: _ information is correct.I agree to comply with all city and county ordinances 316 29 028 , and state laws relating to building construction,and hereby authorize representatives of this city to enter,upon the above mentioned property for , ;' inspection purposes. (We)agree to save indemnify and keep harmless the PERMIT EXPIRES IF WORK IS NOT STARTED City of Cupertino against liabilities,judgments,costs,and expenses which WITHIN 180 DAYS OF PERMIT ISSUANCE OR may accrue against said City in consequence of the granting of this permit. - Additionally,the applicant understands and will comply with all non-point 180 DAYS FROM LAST CALLED INSPECTION. source regulatio s per the Cupertino Municipal Code,Section 9.18. ' 'I �-' Issued by:Abby Ayende � • ture Date 10/24/2017 Date: 10/24/2017 OWNER-BUILDER DECLARATION RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of the All roofs shall be inspected prior to any roofing material being installed.If a roof is following two reasons: installed without first obtaining an inspection,I agree to remove all new materials for 1. I,as owner of the property,or my employees with wages as their sole inspection.' compensation,will do the work,and the structure is not intended or offered.for sale(Sec.7044,Business&Professions Code) • Signature of Applicant: . 2. I,as owner of the property,'am exclusively contracting with licensed Date: 10/24/2017 , 1 contractors to construct the,project(Sec.7044,Business&Professions Code). . , I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided:forby Section 3700 of the Labor Code,for the HAZARDOUS MATERIALS DISCLOSURE performance of the work fo'r which this permit is issued. I have read the hazardous materials requiridnments under Chapter 6.95 of the 2. I have and will maintain Worker's Compensation Insurance,as provided for by California Health&Safety Code,Sections 25505,25533,and 25534. I will Section 3700 of the,Labor Code,for the performance of the work for which this maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the permit is issued. Health&Safety Code,Section 25532(a)should I store or handle hazardous • 3. I certify that in the performance of the work for which this permit is issued,I material. Additionally,should I use equipmetip'or devices which emit hazardous shall not employ any person in any manner so as to become subject to the air contaminants as defined by the Bay l it Quality Management District I will maintain compliance with the Cupertino tino Municipal Code,Chapter 9.12 and Worker's Compensation laws of California. If,after making this certificate of the Health&Safety Code, ctions 25505,25533,and 25534. exemption,I become subject to the Worker's Compensation provisions of the 1 '1 Labor Code,I must'forthwith comply with such provisions or this permit shall i, 'I ._r or authorized agent: be deemed revoked. a e: 0/24/2017 I i' • APPLICANT CERTIFICATION CONSTRUCTIO ENDING AGENCY I certify that I have read this application and state that the above information is , I hereby affirm that there is a construction'lending agency for the performance correct.I agree to comply with all city and county ordinances and state laws of work's for which this permit is issued'(Sec 3097,Civ C.) relating to building construction,and hereby authorize representatives of this city Lender's Name i to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities, Lender's Address . judgments,costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands ARCHITECT'S DECLARATION and will comply with all non-point source regulations per the Cupertino Municipal I understand my plans shall be used as public,records. Code,Section 9.18. Licensed Signature Date 10/24/2017 Professional \\' ./ ALTERNATIVE ENERGY PERMIT APPLICATION AE ri.: COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION e.,,s, 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinq(a'�.cupertino.orq CUPERTINO b-Zofl- rke PROJECT ADDRESS 0 2 g5 col_ IA J _ APN# �1 r-^2.9-025 OWNER NAMI~�.P�2v\6-Zin —k`' ' PHONE /� .0;12,2�Q� EI Ole CtAI al_„• e r 4';0. 1 .^ Co STREET ADDRESS ^ 5i ' CITY,STATE,ZIP FAX / CONTACT NAME^ ev1 PHON$ 0Z 8.1 ci��s E ms!1 t1 p i %),,1 NAVs.Acx, %),,1NVsqcr' c.. STREET ADDRESS .b52-f PC.r �2h A AVL CITY,STATE,ZIP�a� �� 0 FAX o OWNER 0 OWNER-BUILDER 0,OWNER AGENT 0 CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME T e N'��I�\ LICENSE NUMB�/R��O �� LICENSE TYPE BUS.LIC# COMPANY NAME (1Jl E-MAIL I I �` —1 FAX 11�,\fiSatc:, _III L rL relv,v bl- .L. STREET ADDRESS CITY STATE PHONE 5 LI ' e• .,Na(A0 b0-la- CA cla ' '8 4'2)992 ARCHITECT/ENGINEER NAME LICENSE NUMBER , ( BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF cFD or Duplex 0`'Multi-Family PROJECT IN WILDLAND PROJECT IN , STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE ❑ Yes 0 No SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: t KILOWATTS(COMMERCIAL ONLY): /. ,Z Ll' TOTAL VALUATION: /- 5 2'` 0-e,`7 / -1. DESCRIPTION OF WORKICD\Ctr Y rC l....1 —1...,„S re.,N\--i • • RECEIVED BY: " "}� � - "V• �."+ Bymysignature below,I certify to each of the following: I am the property owner or authorized agent to act on the roe owner'sbeh lf. I ha read this gfY g P P Y g property rtY application and the information I have pr vided is correct. I have read'the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to buil 'ng construction. I authorize representatives of Cupertino to enter the d//above-identified p;opertyyffor inspection purposes. ' Signature of Applicant/Agent: Date: 1 f„29/// /7 SUPPL _ NTAL INFORMATION'REQUIRED OFFICE USE.ONLY �,,A h\/\ W 0 OVER-THE COUNTER ('" ,q\*'"1 V U/ ❑ EXPRESS \J V .. ❑ STANDARD • ❑ I ARGE, e 0 MAJOR ' PVApp_2011.doc revised 03/16/11 s SMOKE / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a)-cupertino.org PERNIIT CA",OT BE�NALED :UNTIL THIS CERTIFICATE HAS ,BEEN: CUMPLET'1ED; 94QaD_: AND RETURNED. TO TE,[E BUHbINQ I MSI0N PURPOSE This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2016 CRC Section R314, R315, 2016 CSC Sections 420 6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000 00, CRC Section R314, R315, and CBC Sections 907.2.11.5 and 420 6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations. AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) - (Smoke alarms shall not be located within 3 feet of bathroom door) X X On every level of a dwelling unit including basements and habitable attics X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420 6 and shall be approved by the Office of the State Fire Marshal. Power Supply In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11 4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed m accordance with the manufacturer's instructions and in compliance with the California Building and California Residential Codes. The alarms specified below have been tested and are operational, as of the date signed below Address ),,0')_0 -) C a Q V_( Specify Number of Alarms # Smoke Alarms Permit No. R_ W 1'3-~iW # Carbon Monoxide Detectors. t have read and agree to comply with the terms and conditions of this statement Agent's) Name: O ner�(or Owner Ag � �f Y tA,-i Signature ... .. Date: .. .. Contractor ttNam . r Si nature Lic.# "(. .l. Date: Smoke and COforin.doc revised 0111012017 VICINITY MAP SCALE: NTS SATELLITE VIEW SCALE: NTS PHOTOVOLTAIC SYSTEM SUMMARY SYSTEM SIZE: DC STC: 4.29 KW SYSTEM SIZE: AC CEC: 3.94 KW SOLAR MODULES: (13) LG330N1C-A5 INVERTER: (1) SOLAR EDGE SE3800H-US MOUNTING SYSTEM: IRONRIDGE ROOF MOUNT ELECTRICAL INFORMATION: EXISTING MAIN SERVICE PANEL BUS SIZE: 125A MAIN SERVICE BREAKER SIZE: 125A BUILDING INFORMATION: ONE STORY HOUSE CONSTRUCTION TYPE: V-B OCCUPANCY: R ROOF: COMP. SHINGLE TRUSSES: 2"x4" @ 24" O.C. Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 Lic# 960376 Class C-46 INSTALLERSHEET INDEX ADDRESS: 10285 Colby Ave, Cupertino, CA 95014 PROJECT NAME: Debanjan Mukherjee STREET VIEW SCALE: NTS THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL BE IN ACCORDANCE WITH THE MOST RECENT CPC, CMC, 2016 CEC, 2016 CRC, 2016 CBC AND 2016 NEC. AS AMMENDED BY THE LOCAL AHJ. STRUCTUAL CONNECTIONS SHALL BE TO 2016 IBC. GENERAL NOTES 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY REC OG N I ZED E L E CT R IC A L T E ST IN G L A B O R A TO RY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, U T I L I T Y C O . A N D C I T Y I N S P E C T O R S A S N E E D E D . 6. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS C A P A B L E O F W I T H S T A N D I N G T H E E X T R A W E I G H T . 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK PHOTOVOLTAIC NOTES: 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. ALL WORK SHALL BE IN ACCORD WITH THE 2016 CBC, 2016 CEC AND 2016 NEC WITH SPECIAL EMPHASIS ON ARTICLE 690 13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.166 15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-166. 16. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS ROOF PLAN SINGLE LINE DIAGRAM RACKING DATA SHEET ATTACHMENT LAYOUT CODE REQUIRED SIGNAGE INVERTER DATA SHEET P 1 MODULE DATA SHEET MODULE & RACK CERTIFICATION RACKING SPECS ATTACHMENT DATA SHEET OPTIMIZER DATA SHEET DESIGNER NAME: NAREK A. DATE: 20 OCTOBER, 2017 SITE PLAN C 1 COVER SHEET P 2 P 3 P 4 P 5 P 6 P 7 P 8 P 9 P 10 P 11 P 12 C1 Abby Ayende 10/24/17 10/24/17 B-2017-1816 Abby Ayende 1 ROOF PLAN Drawn By : Narek A. CONTRACTOR N 0° S 180° E 90° W 270° X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED PHOTOVOLTAIC ARRAY (13) LG Electronics 330 W Solar Modules (LG330N1C-A5) (1) Solar Edge 3.8 Kw Inverter (SE3800H-US) (13) Solar Edge P400 Power Optimizers EMT Type Conduit MSP (E) 125A Main Service Panel Solar Module J/B (N) Junction Box UNIT INDEX Power Optimizer MATERIAL LIST TABLE Module : 13 x LG330N1C-A5 Optimizer : 13 x P400 Power Optimizers Inverter : 1 x SE3800H-US Rails : 7 x 168" Iron Ridge Rails Attachment :x 26 Dual Jack Standoff Ground Lug :x 4 Ironridge UFO Ground Lugs End Clamp :x 8 Ironridge UFO End Clamps Mid Clamp :x 22 Ironridge UFO Mid Clamps Channel Strut: 13 Monitoring Gateway: x 1 INV (N) Solar Edge 3.8 KW Inverter SCALE 0 5 10 ft1 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT Note: This installation will provide verification at time of inspectionthat 2016 CRC sections 314/315 (smoke and CO detectors) are in compliance. 1.UFO GROUNDING MID CLUMP 2.UFO END CLAMP 3.IRONRIDGE RAIL 4.UFO GROUND LUG 5.ONE LUG BETWEEN TWO SPLICES OF RAILS 6.ONE LUG AT THE END OF THE RAIL TO GO TO THE J-BOX 7. #6 BARE COPPER EGC 8.PV MODULES GROUNDING AND CLAMPING DETAIL UL 2703 AND UL467 CERTIFIED 1 2 4 5 7 8 Colby Ave3' fire setback 3' fire setback 3' fire setback 3' fire setback1 8'' fire s e tb a c k 18'' fire setbackMSP INVJ/B Solar Array 13 LG 330W Modules 13 P320 Optimizers Pitch: 18 Deg Orientation: 270 Deg Abby Ayende 10/24/17 NEW SPLIT PHASE: 3W, 120/240V BUSBAR RATING = 125A MAIN SERVICE BREAKER = 125A END FEED 120% RULE: MAX ALLOWED FEED: 150A ACTUAL FEED: 125A "MSP" + 20A "SOLAR" = 145 A <= 150A MAX MAIN PANEL RATING All the photovoltaic systems wires that on the roof and side of the building shall be protected against physical damage 2 SINGLE LINE DIAGRAM CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED OUTPUT CALCULATIONS PV ARRAY INFORMATION PV MODULE RATINGS # STC INVERTER RATING 13 LG ELECTRONICS 330WATT SOLAR MODULES MODEL # LG330N1C-A5 1 SOLAR EDGE 3.8 KW INVERTER MODEL # SE3800H-US NUMBER OF STRINGS PER INVERTER: 1 NUMBER OF SERIES PER STRING: 13 MAX DC WATTAGE: 13 * 330W = 4,290W <= 5,700W MAX DC VOLTAGE: 380V EXISTING GROUND ROD MAIN METER UTILITY EXISTING 125A MAIN SERVICE PANEL 120/240V 1-PHASE, 3-WIRE INSTALL 2P 20A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 125A BUS125A END FEED MAIN C/B [DC.1] [DC.2][AC] 3/4" EMT CONDUIT 2 FEET #6 AWG EGC COPPER WIRE RAIL GROUNDING MID CLAMP GROUNDING LUG [ DC.1 ] FROM PV MODULES TO J-BOX (2) #10 AWG PV WIRE + (1) #6 AWG BARE CU EGC FREE IN THE AIR, 3/4" EMT TYPE CONDUIT BETWEEN PV ARRAYS 3/4" EMT CONDUIT 30 FEET Drawn By : Narek A. SolarEdge Power Optimizer P400 Rated DC Input Power - 400 watts Maximum Input Voltage - 84 Vdc MPPT Range - 8 to 84 Vdc Maximum Input Current - 12.5 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum NOTE: Grounding specs:Ironridge has a UL1703 Listed integrated grounding. No additional ground lugs and copper wire are needed (See integrated grounding spec sheet on page #11) The system is Rapid shut down ready by CEC 690.12 PV SYSTEM MAX DC OUTPUT: 13 * 330W = 4,290W PV SYSTEM MAX AC OUTPUT: (13) LG ELECTRONICS LG330N1C-A5 (1) SOLAR EDGE SE3800H-US Pmax (PTC Rating) PER MODULE: 306.3W 306.3W * 13 = 3.98 KW 3.98 KW * 99.0% CEC INVERTER = 3.94 KW PHOTOVOLTAIC ARRAY 1 STRING OF 13 MODULES 13 LG ELECTRONICS 330WATT MODULES, 13 P400 POWER OPTIMIZERS 1 2 ... 13 JBOX NEMA 3R 6" BY 6" PEAK PWR TRACKING VOLTAGE = 380 V CEC EFFICIENCY = 99.0 % ENCLOSURE : NEMA 3R MAXIMUM INPUT CURRENT = 10.5 A MAXIMUM OUTPUT CURRENT = 16.0 A MAXIMUM INPUT POWER = 5900 W MAXIMUM OUTPUT POWER = 3800 W SOLAR EDGE 3.8KW INVERTER MODEL# SE3800H-US WITH INTEGRATED RAPID SHUTDOWN Max Input Voltage: 480V [ DC.2 ] FROM J-BOX TO INVERTER (2) #10 AWG THWN-2 + (1) #8 AWG CU EGC 3/4" EMT TYPE CONDUIT MAXIMUM CURRENT : 13 * 330W / 380V = 11.3A CONSIDERS CONTINUOUS: 11.3A * 1.25 = 14.1 A SHORT CIRCUIT CURRENT: 14.1 A * 1.25 = 17.6A RACEWAY HEIGHT FROM ROOF 1 1 2'' (TEMP - 39 + 22 = 61C) TEMP. DERATE FACTOR - 197.6 A / 0.58 = 30.4A WIRE SIZE FROM NEC TABLE 310.15(b)16 - 10 AWG AMBIENT TEM FACTOR 0.58 PER NEC 310.15(b)(2)(a) [ AC ] FROM INVERTER TO MAIN SERVICE PANEL (3)#10 AWG THWN-2 + (1) #8 AWG CU EGC 3/4" EMT CONDUIT MAXIMUM INVERTER OUTPUT CURRENT : 16.0 A CONSIDERS CONTINUOUS: 16.0A * 1.25 = 20.0 A TEMPERATURE ADJUSTMENT - 20.0 A / 0.91 = 21.97A CONDUCTOR SIZE FROM NEC TABLE 310.16 - 10 AWG SHORT CIRCUIT CURRENT I-SC = 10.45A MAXIMUM POWER CURRENT I-MP = 9.80A OPEN CIRCUIT VOLTAGE V-OC = 40.9V MAXIMUM POWER VOLTAGE V-MP = 33.7V Abby Ayende 10/24/17 CAUTION Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. 1 2 (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) 3 4 WARNING! ELECTRIC SHOCK HAZARD. DO NOT TOUCH THE TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. 5 (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) 6 7 8 THIS PANEL FED BY MULTIPLE SOURCES (UTILITY & SOLAR) 9 SOLAR (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE10 (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV ARRAY J BOX INVERTER INTEGRATED DC DISCONNECT PV SUB-PANEL * if applicable SUB-PANEL * if applicable AC DISCONNECT * if applicable METER MAIN SERVICE PANEL 2 1 3 4 5 6 7 9 8 10 7 9 8 10 7 7 9 8 10 MARKINGS, LABELS AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.CFC 605.11.1 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. CFC 605.11.1.1 3.Marcking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 4.Marcking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CFC 605.11.1.3 *if applicable PV SUB-PANEL ONLYCAUTION AUTHORIZED SOLAR PERSONNAL ONLY! CAUTION SOLAR DC CURRENT PRESENT DURING DAYLIGHT HOURS AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: 16 .0 A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. DC DISCONNECT DC PHOTOVOLTAIC POWER SOURCE RATED MAX POWER POINT CURRENT-9.80 AMPS RATED MAX POWER POINT VOLTAGE- 380 VOLTS MAXIMUM SYSTEM VOLTAGE- 480 VOLTS SHORT CIRCUIT CURRENT- 17.6 AMPS 11 (STICKER LOCATED ON THE PV SUB PANEL) 11 PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. 3 CODE REQUIRED SIGNAGE CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. N 0° S 180° E 90° W 270° POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 12 (STICKER LOCATED ON THE MAIN SERVICE PANEL) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUT DOWN 12 SERVICE POINT & UTILITY METERING SOLAR INVERTER SOLAR PV ARRAY ON ROOF Colby AveAbby Ayende 10/24/17 4 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. SITE PLAN N 0° S 180° E 90° W 270° SCALE 0 5 10 20 ft MSP (Е) Main Service Panel Solar Module UNIT INDEX INV (N) Inverter Power Optimizer MSP INV Colby AvePublic SidewalkDriveway 115' 70' 9' 41' 38' 63' Abby Ayende 10/24/17 ATTACHMENT LAYOUT 5 CONTRACTOR 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. MODULE WEIGHT (lbs) # OF MODULES TOTAL MODULE WEIGHT (lbs) RACK WEIGHT (lbs) TOTAL SYSTEM WEIGHT (lbs) # OF STANDOFFS MAX SPAN BETWEEN STANDOFFS (in) LOADING PER STANDOFF (lbs) TOTAL AREA (sq.ft.) LOADING (PSF) FLASH MOUNTING DETAIL 39.7 13 516 103 641 26 48 24.7 2.74 234 EXISTING 2" BY 4" @24" O.C. ROOF TRUSSES IRONRIDGE XR10 RAIL OPTIMIZERS WEIGHT (lbs)22 ATTACHMENT DETAILS L-FOOT GF-1 FLASHING 5/16" * 3.5" HANGER BOLT MIN. 2.5" EMBED INTO FRAMING MEMBER FRAMING MEMBER SHEATHING EPDM WASHER 5/16" EPDM BONDED 304 18.8 SS WASHER IRONRDIGE XR10 RAIL X 5" SOLAR MODULE Existing Roof Trusses 2" BY 4" @ 24" O.C. 2"x6" Blocking 18° 2"x4" Purlin ATTACHMENT 1. Ironridge Racking System 2. Eco Fasten Flashing Attachment 3. Racking loading calculations were performed for ASCE 7-10 wind speeds @ 110 mph for B and C exposure categories and ASCE 7-10 Seismic Design Category E. 4. Roof attachment hardware to be mounted to existing structure (2"x4"@24" O.C.Trusses) at 48" O.C. rail spans or less. 5. Lag bolts are 5/16" X 3.5" stainless steel with 2.5" minimum embedment into the roof rafters. 6. Roof sheathed with 1/2" plywood and upper surface is faced with felt paper. Finished roof surface is One Layer of Composition Shingle . 7. Mounts or/and mounting hardware will be sealed with Tremco Vulkem 116 Polyurethane Sealant or equivalent. 48" 24" Abby Ayende 10/24/17 6 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED INVERTER DATA SHEET Drawn By : Narek A. Abby Ayende 10/24/17 7 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED OPTIMIZER DATA SHEET Drawn By : Narek A. Abby Ayende 10/24/17 MODULE DATA SHEET 8 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Abby Ayende 10/24/17 RACKING CERTIFICATION 9 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Abby Ayende 10/24/17 RACKING DATA SHEET 10 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Abby Ayende 10/24/17 RACKING SPECS 11 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Drawn By : Narek A. Abby Ayende 10/24/17 ATTACHMENT DATA SHEET 12 CONTRACTOR X 20 OCTOBER, 2017 10285 Colby Ave, Cupertino, CA 95014 Debanjan Mukherjee Lic# 960376 Highlight Solar Inc. Address: 1624 Remuda Lane, San Jose, CA 95112 Phone Number: (866) 926-9997 PV SYSTEM AS INDICATED Abby Ayende 10/24/17