Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13120169
CITY.OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21753 CASTLETON ST CONTRACTOR:SOLARCITY PERMIT NO: 13120169 OWNER'S NAME: MAKARAM NARAYAN AND SUJATA TRUSTEE 3055 CLEARVIEW WAY DATE ISSUED: 12/19/2013 OWNER'S PHONE: 4088131076 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ CO INSTALL PV SYSTEM ON SFDWL ROOFTOP 20 PANELS 5.3 License Class C O I Lic.tl I KW Contractor_ o Date 1 I hereby affirm that I am license under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$20000 1 have and will maintain Worker's Compensation Insurance,as provided for by -Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35618071.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION [.certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. —1��/ �2' f RE-ROOFS: Signature C,-Date All roofs shall be inspected prior to any roofing material being installed.If roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sec 'ons 2 505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized agent: Date: I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of Califomia. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCH ITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION12 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 �LoAE CUPERTINO (408) 777-3228• FAX(408)777-3333• buildingcDcupettinG.Grg �3\\,p PROJECT ADDRESS G 1-�e3 &5�he (-i APN tl 2 C'w 0 rf/ OWNER NAME PHONE J7U/ dE-MAIL STREET ADDRESS �1 CITY, STA_TIE�Z�iP� -15Diq FAX CONTACT NAME V'j PHONE/ ® %M E-MAIL STREET ADDRESS CITY„STATE. ZI qc q FAX ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTORNAMB-, LICENSE NUMBER UgQ®�J LIICCENNSE TYPPE� BUS.LIC 0 COMPANY NAME E-MAIL ` ` -'JC STREET ADDRESSY,STt TE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC N COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ NO FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION TO SOLAR WATER HEATING ❑ OTHER: FOR SO/.4R PANE45: NUMBER OF PANELS/UNITS: q KILOWATTS: c ,� TOTAL VALUATI :-2 r 0 bG DESCRIPTION OF WORK I { RE�E1GEt7�Yy:? E - By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. 1 have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relatingt buil ng constru ion. uthorize repr ati of Cupertino to enter theabove-identifiedproperty for inspection purposes. Signature of Applicant/Agent: L_._� Date: I�' Le v SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY w ❑ OVER-TITE-COUNTER a r I' EXPRESS tz U x 0- STANDARD. U 'LARGE MAJORi P VApp_2012.doc revised 06/20112 CITY OF CUPERTINO FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 21753 Castleton St DATE: 12/23/2013 REVIEWED BY: Mendez APN: BP#: j� ���p �7 *VALUATION: 1$20,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: wORK install pv system on sfdwl rooftop 20 panels 5.3 kw SCOPE 0. Marl Che(,, f lac. P41rt t� ec.0 t4ex:ft..Yerlrri;'<e e: Phc;ulr. Prrrrria Fire`: Zsfer.Pemlit Fce_ Oflu r . ,4t,Insr. 0 e. , i.«rlh Insp, E:17 � Fish. A1ech. trtsp. Fee,, PfWntr.In�p. Fee: Stec_hup. i r , NOTE. This estimate does not include fees due to other Departments(i.e.Planning,Public Works, Fire,Sanitary Sewer District,School District,etc. . Theseees are based on the prelimin information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 711/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 # Alternative Energy System Suppl. PC Fee: Q Reg. C) OT 0.0 lus $0.00 $229.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-.0 Reg. C) OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 C onsFructian 1(": Ailministrevive Fee: Work Without Permit? Yes No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential G 1'r-ctvel 1)ocunrcniarion Fees; Building or Structure Strong Motion Fee: 1BSEISMICR $2.00 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 u 5 `Ic(dTALS: $3.00 $229.00 TOTAL FEE: $232.00 Revised: 10101/2013 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE DEC 19 2013 EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY s CUPIL-RTINO (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. B�.';� Building Department EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) 'E C(JVPLIANCE I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR COMMUNITY Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC DEVELOPMENT DEPARTMENT CT BUILDING DIVISION- UPERTINO kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN APPROVED LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY MIN MINIMUM UL LISTING. This set of plans and specifications MUST be kept at the 'OT pY,APIS (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE job site during construction. It is unlawful to make any C>�ECKED BY,changes or alterations on same,or to deviate 7 NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE therefrom,without approval from the Building Official. NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING DAWV OC ON CENTER HARDWARE. The stamping of this plan and specifications SHALL NOT PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE be held to permit or to be an approval of the violation EpT„ POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND of any provisions of any City Ordinance or State Law. PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. S I d SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR BY DAA SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(8) & DATE 2- �� • _ STC STANDARD TESTING CONDITIONS 690.47. PERMIT NO. 13126 I(a q > C. DEM. TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Vac VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT PVI COVER SHEET PV2 SITE PLAN I�) PV3 STRUCTURAL VIEWS 1�! PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES PV5 THREE LINE DIAGRAM Cutsheets Attached I l CA # 888104 1. THIS SYSTEM IS GRID—INTERTIED VIA A X C-10 UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. _ 3. SOLAR MOUNTING FRAMES ARE TO BE OFFICE COPY GROUNDED. 4. ALL WORK TO BE DONE TO THE 2010 MODULE GROUNDING METHOD: SLEEKMOUNT CALIFORNIA BUILDING CODE. AHJ: Cupertino 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV BY DATE COMMENTS THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2010 CALIFORNIA ELECTRIC CODE. REVA NAME iz/tfi�zoi COMMENTS UTILITY: Pacific Gas and Electric Company (PG&E) x # CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: PREMISE^W'! = DESCRIPTIOK DESIGN: CONTAINED SHALL NOT BE USED FOR THE JB-9502387 00 MAKARAM, NARAYAN MAKARAM RESIDENCE Rick WoodS • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: V NOR SHALL IT BE DISCLOSED IN MOLE OR IN Comp Mount Type C 21753 CASTLETON ST 5.3 KW PV Array �,1` O�af��t 1 PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. CUPERTINO CA 95014 ORGANZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECnVE (20) SUNIVA # OPT265-60-4-1B0 3055 aEOfn°"'Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN S teo, CA 9W2 INVERTER: PAGE NAME. SH ' Wit DATE' T:(650)Son Ma 8 F:(650)638-1029 PERMISSION OF S"CITY INC. SOLAREDGE # SE5000A—US (408) 813-1076 COVER SHEET PV 1 12/16/2013 (aha)-SOL-CITY(765-2489)www.solucity.com l PITCH: 18 ARRAY PITCH:18 MPl AZIMUTH: 198 ARRAY AZIMUTH: 198 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 18 ARRAY PITCH:18 M132 AZIMUTH: 198 ARRAY AZIMUTH: 198 MATERIAL:Comp Shingle STORY: 2 Stories I -< CJFERTINO Building Department :w G FOR CODE CCiMPLIHNGE J ! h4711/ LEGEND L N�P1 O (E) UTILITY METER & WARNING LABEL �p7 g e 9etbNdF _ _ _ _ \_3'Fire Setback r INVERTER W/ INTEGRATED DC DISCO O I — — — — Inv & WARNING LABELS Inv I lO E DC DISCONNECT & WARNING LABELS II © AC DISCONNECT & WARNING LABELS I I O I DC JUNCTION/COMBINER BOX & LABELS n oc e B i A O DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS I I I ODRIVEWAY ; M DEDICATED PV SYSTEM METER I I CONDUIT RUN ON EXTERIOR Un-Locked Gated --- CONDUIT RUN ON INTERIOR I GATE/FENCE I I I ` INTERIOR EQUIPMENT I I L—'J Front of House SITE PLAN N TOTAL ARRAY AREA (SF): 356 Scale: 1/8" = 1' � TOTAL ROOF AREA (SF): 2839 W TOTAL ARRAY AREA IS a2.56 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER:- PREMISE 0o PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MAKARAM, NARAYAN MAKARAM RESIDENCE Rick Wood • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: _ .,SO�af�lty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21753 CASTLETON ST 5.3 KW PV Array ►,,, ` Cr . PART TO OTHERS OUTSIDE THE RECIPIENTS MOT1U�5 — C U P E R TI N O CA 95014 A�Al ORGANIZATION, EXCEPT IN CONNECTION WITH 3056 aWrkx woy THE SALE AND USE OF THE RESPECTIVE (20) SUNIVA # OPT265-60-4-160 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET. �' DAR: Son T:(650)638 Mateo,1028CA 94402 )638 1029 PERMISSION SOLARCITY INC. SOLAREDGE SE5000A-US (408) 813-1076 SITE PLAN PV 2 12/16/2013 (998)-SOL-aTY(765-2489)wrM.adorcily.com S1 S1 (E) 2x6 2' 7'-6" " (E) LBW —10 7'-4„ ,-1„ SIDE VIEW O F M P 1 RAFTER: (E) 2x6 @ 24" O.C. (E) LBW A NTS CEILING JOIST: (E) 2x6 @ 16" O.C. SIDE VIEW OF M P2 RAFTER: (E) 2x6 @ 24" O.C. RIDGE: (E) 2x6 RIDGE BOARD " B NTS CEILING JOIST: (E) 2x6 @ 16" O.C. MAX SPAN: 7'-6 RIDGE: (E) 2x6 RIDGE BOARD MAX PORTRAIT STANDOFF X—SPACING: 72 O.C. MAX SPAN: 7'-4" MAX PORTRAIT STANDOFF X—SPACING: 72" O.C. h VUI ER \ f h'` o PV MODULE Budding ..FaD� ,-,rrlTe Flt 5/16" BOLT PATH LOCK INSTALLATION ORDER & FENDER WASHERS ;.; 2n. LOCATE RAFTER, MARK HOLE �3 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. E EVIEVVED FOR CODE (.CtV PLIANCE (4) (2) SEAL PILOT HOLE WITH Reviewed By ZEP COMP MOUNT C POLYURETHANE SEALANT. Y ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (I) (4) PLACE MOUNT. (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (S�I SEALING A IN WASHER, WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES ( ) INSTALL LEVELING FOOT NTH (2-1/2" EMBED, MIN) 6 BOLT & WASHERS. (E) RAFTER 1 STANDOFF Si Scale: 1 1/2"= 1' CONFIDENTIAL — THE INFORMATION HEREIN JOBNUMBER-- JB-9502387 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED DALMAKARAM, NARAYAN MAKARAM RESIDENCE Rick Wood �SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: fi NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21753 CASTLETON ST 5.3 KW PV Array e,`SolarC•te PART TO OTHERS OUTSIDE THE RECIPIENT'S MGouLEs CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION KITH , THE SALE AND USE OF THE RESPECTIVE (20) SUNIVA # OPT265-60-4-1130 10641 3055 Clearvieww way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHS: REV: DATE: T:(650)Son Ma 8 CA 94402 )638-1029 PERMISSION OF SOIARaTY INC, SOLAREDGE # SE5000A—US (408) 813-1076 STRUCTURAL VIEWS PV 3 12/16/2013 c»)-SQL-CITY(765-2489)ww.edorcity.com UPLIFT CALCULATIONS 1216.2013 - ;So�arCit . SleekMo�untTm PV System version X17.6 ; yStructural Design. lice __. __,_�� CUPERTIt4,01 it ii nafif>Ki Id:n 9 D.-p2rtment Comp Rod UL 180 E COMPI.AANCE PV Module Orientation Portrait v ``•s•� ��fir SYsfiern _ � - PV Module Width 39" SWinclaff Attadlment Hardware Comp.CompMount Type C. P ... .__r Ground Snow Load 0.0 ASCE Ta61e 7-1 _ lRoofi 5aow Ow PV Mod es ao ASS MEq, A Wind Dedon Code �-os NO M Bash WindSpeedV 85 mph_ 6.1 43 - _ fl . Roof Style Gable Roof a9 6-LWQV-14A/a Ofedi've Wind 1 Module A 17.5 sf IBC 1509.7.1 Wind Preoure re lO 0.95 Table B-3 .UMM"WiNgiff _—_ _ Wind Dtre4fflonWr4 Fador Kd 0.85 Table fro Vdocft PnI� a ffi O.Ow". )(KA) N^2) Equation 6-15 1 l Premie Coefficient NP7 � )_. -1.88 a-�uvao- vs n V ind Presikxo p P=Sh 6-22 YMh d Prune Down down Mo psf Max Allowable Standoff t Paralt .. 72"w ANN 65" Standoff G(Mouration Portrait I P'V Deed Load W-PV 3 BMW ,.._. ILIA-OAxidy of Standoff T-allow 637`8fis JB-9502387 00 000 OESMMt DEM oa�,M SI - THE SSM MEN is Num MAKARAM, NARAYAN MAKARAM RESIDENCE Pick Wood '- SolarGity.OOIITAL�D SHAl1 NOT 8E USEO Fdt THE HIM sBENM+MI SIT BE ANYONE M w`WH«F INC.,R IMOUNTINGSYSiO` 21753 CASTLETON ST 5.3 KW PV Array PART TO OTHERS OUTSDE THE RECIPIENTS Com Mount Type C oROMMMON,DI PT IN COMECTION V"M CUPERTINO, -CA -95014 3065 a -.---THE SALE AND USE aI THE RE TINE 20) SUNIVA OPT265-60-4—lB0 WLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME SHEET- Rcl! DATE 1(650)638-102San 8 CA (SW)638-1029 PI�t►usaoN aI SOLAR(]TY INC. SOLAREDGE SE5000A-US (408) 813-1076 UPLIFT CALCULATIONS PV 4 12/16/2013 (BIRT-SOL-CITY(765-2489)www.saWdtycorn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number:Murray Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ## SE5000A-US �ABE A -(20)SUNIVA # OPT265-60-4-1BO CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006137188 Inverter; 5000W, 240V, 97.51; wrZB; SE1000-ZB02-SLV-NA PV Module; 265W, 237.4PTC, H4, Black on Black, ZEP Enabled C-10 INV 2 Voc: 38.3 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200/2P MAIN CIRCUIT BREAKER SalarCity Inverter 1 4 A 1 5 SOLAREDGE oc• " 200A/2P SE5000A-US �-----1 String(s)Of 10 On MP i- (E) LOADS _ EGc I • L2 GFP/GFCI DC+ I N DC- I 3 PD 3OA/2P __________ EGC! _ Dc�F-------------------------------------- A GEC © DC- 1 Strings)Of 10 On MP 11]13) E - ----------- -----------------� - I (1)Conduit Kit; 3/4' EMT N I I EGGGEC - Z Z k9 GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I 7p CUPER wilding Dep I , I I REVIEWED FOR CODE COMPLIANIC' Reviewed By ��-.� srT.%r• Voc* = MAX VOC AT MIN TEMP O1 (1)MURRAY/MP230 PV BACKFEED BREAKER /t► A Breaker 3OA 2P, 2 Spaces /-, (1)SdarC ty! 4 STRING JUNCTION BOX DC -(I Break Rod; 5/S' x S', Copper 2x2 STRINGS, UNFUSED, GROUNDED -(2)ZEP 850-1196-001 Com finer Box Bracket; For ZEP, bottom mount only PV (20)SOLAREDGE1 OP300-MV-AH4SM-2NA-Z PowerBox ptimizer, 30OW, 1-14, DC to DC, ZEP (1)AWG#10, THWN-2, Black (1)AWG #10, THNN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG 110, PV 1NRE, Block Voc* =500 VDC Isc =15 ADC O (1)AWG#10, THWN-2, Red O�(1)ANG #10, THNN-2, Red Vmp =350 VDC Imp=7.47 ADC O (1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=7.47 ADC LLLLLL����LLLLLL(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=21 AAC IILLLL.����LLLLLL(1)MNG /10, THWN-2, Green EGC . . . . . . . . . . . . . . . . . . . . . . . .-(1)AWG 18,.THWN-2,.Green. . EGC/GEC.-(1)Conduit.Kit;_3/4'.EMT . . . . _ . . . (1)AWG #10, THNN-2, Black Voc* DC 500 VIsc 15 ADC �(2)AWG #10, PV 1NRE, Black Voc =500 VDC Isc =15 ADC ® (1)AWG #10, THWN-2, Red Vmp =350 VDC Imp=7.47 ADC O I'cr"t-(1)AWG #10, Solid Bare Copper EGC Vmp =350 VDC Imp=7.47 ADC . . . . . . . . (1)AWG #10, THWN-2, Green EGC . . . . .I. . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I . . . . . . . . . . . . . . . CONFIDENTIAL - THE INFORMATION HEREIN 1(20) OB NUMBER PREMISE ONNER: DESCRIPTION: DESIGN: JB-9502387 00 _��� CONTAINED SHALL NOT BE USED FOR THE MAKARAM NARAYAN MAKARAM RESIDENCE Rick Wood ���'• BENEFIT OF ANYONE EXCEPT SOLARCITY INC., OUNTING SYSTEM: �•�� SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR INComp Mount Type C 21753 CASTLETON ST 5.3 KW PV Array ��� . PART TO OTHERS OUTSIDE THE RECIPIENT'S ODDLES C U P E R TI N 0 C A 9 5014 ORGANIZATION, EXCEPT IN CONNECTION YNTH r THE SALE AND USE OF THE RESPECTIVE SUNIVA # OPT265-60-4-1BO 3M My SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 94402 INVERTER PAGE NAME SHS' REV.• DATE T:(650) an Mateo, to,F((650)638-1029 PERMISSION OF SOLARCITY INC SOLAREDGE SE5000A-US (408) 813-1076 THREE LINE DIAGRAM PV 5 12/16/2013 (ea6)-saL-CITY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT _ •A CAUTION • Per MAXIMUM AC Code: OPERATING CURRENT ••-: Per Code: CA Fire Guidelines MAXIMUM AC 690.54 SECOND SOURCE IS 690-64.B.4 OPERATING VOLTAGE V PHOTOVOLTAIC SYSTEM Label • • PHOTOVOLTAIC DC ' DISCONNECT Per "- CE 690.14.C.2 Label Location: Label Location: PV SYSTEM ' '' '" WARNING ' DISCONNECT FORPer Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD Label Locati• CEC 690.35(F) THE DC CONDUCTORS OF THIS MAXIMUM POWER- ' Code: PHOTOVOLTAIC SYSTEM ARE • BE USED WHEN POINT CURRENT(Imp)_A UNGROUNDED AND •�- MAY BE ENERGIZED MAXIMUM POWER- INVERTERIS CEC690.53 UNGROUNDED POINT VOLTAGE(Vmp)_V MAXIMUM SYSTEMLabel • • VOLTAGE(Voc)_V WARNING '' SHORT-CIRCUIT_APer Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • • WARNING ' Per ..- CEC ELECTRICAL SHOCK HAZARD •0.17 Label DO NOT TOUCH TERMfNALS TERMINALS ON BOTH LINE AND WARNING P' LOAD SIDES MAY BE ENERGIZEDPer Code: P ERTINO IN THE OPEN POSITION INVERTER OUTPUT 690.64.B.7 DC VOLTAGE IS CONNECTION • •-• • ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE CODE COMPLIANCE Label Location: Label Location: Reviewed By WARNING PHOTOVOLTAIC POINT OF '• Code:Per INTERCONNECTIONPer Code: ELECTRIC SHOCK HAZARD • 690.5(C) WARNING: ELECTRIC SHOCK 690.54; • 90.17 IF A GROUND FAULT 15 INDICATEDHAZARD.DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label • • MAXIMUM AC _ A OPERATING CURRENT Disconnect AC (AC) (POMAXIMUM AC _ Conduit DISCONNECTPer Code: OPERATING VOLTAGE V Combiner CEC .•0 Conduit.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label CAUTIONLoad Center Per Code: SYSTEM 690.64.B.4 •I): Point of • • 7 3055 CJeaAew Way • • • • • •• San Mateo,CA 94402 SCCA Label Set T:(650)638-1028 F:(650)638-1029 • • / solar - • • = •P" . � Single Phase SE300OA-USllOA All our inverters are part of SolarEdge's innovative system - over 97% efficiency and best�in-class reliability. Our fixed- designed to provide superior performance at a competitive voltage technology ensures the inverter is always working at its price. The SolarEdge inverter combines a sophisticated, optimal input voltage,regardless of the number of modules or 1 • 1 1 digital control technology and a one stage,ultra-efficient power environmental conditions. conversion architecture to achieve superior performance Single Phase Invertercl TECHNICAL DATA (North America) .OUTPUT SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7000A-US 5200@208V 5200@208V Rated AC Power Output 3000 3800 5000 60000240V 6000@240V W l`P�;,='. 6000@277V 7000@277V 5200@208V 52000208V Max.AC Power Output 3000 3800 5000 6000@240V 60000240v W 6000@277V 70000277V '�. AC Output Voltage Min.-Nom.-Max. 183-208-229/211-240-264 183-208-229/211-240-264 /244 277-294 Vac AC Frequency Mln.-Nom.-Max. 59.3-60-60.5 Hz Max.Continuous Output Current @208V 14.5 18.5 24 25 25 A ? Max.Continuous Output Current @240V 12.5 16 21 25 25 A Max.Continuous Output Current @277V - 18.5 22 25 A GFDI 1 A t_ -fir= Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Recommended Max.DC Power a(STC) 3750 4750 6250 7500 8750 W Transformer-less,Ungrounded Yes if Max.Input Voltage 500 Vdc ti •i. �, /, Nom.DC Input Voltage 325 @ 208V/350 @ 240V/400 @ 277V Vdc Max.Input Current 10 12.5 1 16 18 18.5 Adc + Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k5Sensitivity Maximum Inverter Efficiency 97.8 97.7 98.3 1 98.3 98.3 % CEC Weighted Efficiency 97,5 97 @ 208V/ 1 97.5@ 208V, 240V 97 @ 208V/97.5@ 240V/ % 97.5@ 240V /98 @: 98 @ 277V Nighttime Power Consumption <2.5 W ADDITIONAL Supported Communication Interfaces RS485,RS232,Ethemet,Zigbee(optional) STANDARD COMPLIANCE Safety UI-1741,IEC-62103(EN50178),IEC-62109 Grid Connection Standards Utility-Interactive,VDE 0126.1-1,AS-4777,RD-1663,DK 5940,IEEE1547 Emissions FCC partly class B,IEC61000.62,IEC61000.63,IEC61000-3-11,IEC61000-3-12 RoHS Yes The only inverters specially designed for distributed DC architecture INSTALLATION SPECIFICATIONS AC Output 3/4'Conduit ■ Superior efficiency(97.5%) DC Input 3/4•Conduit Dimensions(HzWzD) 21 z 12.5 z 7/ 21 z 12.5 z 7.5/540 z 315 z 191in/mm ■ Small,lightweight and easy to install on provided bracket 540 z 315 z 172 ■ Built-in module-level monitoringr ! Dimensions with AC/DC Switch(HxWXD) 30.5 x 12.5 x 7/ 30.5 z 12.5 z 7.5/775 z 315 z 191 In/mm 775x315 x172 >:. v ■ Communication to internet via Ethernet or Wireless Weight 42/19 45/20.5 Ib/kg Weight with AC/DC Switch 48.5/22 52/23.5 Ib/kg ■ Outdoor and indoor installation Cooling Natural Convection ■ Integral AC/DC Switch Min.-Max.Operating Temperature Range -4/-20(CAN version-40/-40)to+140/+60 -F/•C Protection Rating NEMA 3R -r ,•�+ y .,T, p� - •N Inwt DC power .�.O. !t o igbx nary be installeQ analyze yearly AC perlormemos. `C ••TM lv Iw'rg Po l Nunabms e,e aralleble(CMN PNe ere algible(rr-r}1Wr o Me.miavFny. 208/240V.min.."re nii lamp dF/-2(1C:SE3000"S.SMDDALS,SE50DWLS.SE(=O"S.SE7000"S " I f� `' L/v n ;rtm e 11 f 27TC min.a"-rg Iamb-0F/.1(IC:SE500W4US,SESODOa S,SE7000>US ' 208/240v,min,lmam6rg lamp d0F/41M SE3000"&CAN,SEWGALSCJ .SESOOOA.USCAN.SE6000,us-c- ' 217V,min oDarelhg IenaD d0F/-0OCSE5000.WSCAN,SE60DOFUSCAN.SE7000 USCAN ■ USA ■ Germany ■ Italy ■ France ■ Japan ■ China ■ Israel soiar&V W".S0IWWg8.Wm erMBe' ''ol�e'n�rg7y�., _. architects of energyTM 0 SdnEgte Teonno a0ea.ac.20092012.All 10.RAened.SOLIAEDGE.ftSalerEdpe bpp.ARCNRECTS OF ENERGY arta OPTMQED BY SOUREDGE am b dlamea Mau regwlera l trademrb N SC emrEdo,eoim ogros.M.)1ll ✓I`' L (,U?li°P L I A N C E Darr Irab„mrb marwldrd M1aM ere Ire iamedle or Itiir raoaaM ownen.Oale:08/1012.VOO.S,njael ro-ge wllreul rwtir. SolarCity SleekMountT"" - Comp SolarCity tTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTm modules aesthetics while minimizing roof disruption and . Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition •Interlock and Ground Zep ETL listed to UL 1703 • Seal pilot hole with roofing sealant of array trim and a lower profile all contribute P to a more visually appealing system.SleekMount as"Grounding and Bonding System" e Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device a Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance \ • Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions • Secure Leveling Foot to the Comp Mount i using machine Screw lob 0 Place module Components 05/16"Machine Screw • Leveling Foot • Lag Screw Comp Mount C: Comp Mount Flashing 0 0® D; `. 0 E CUPERTINO building Department EVIEVVcU FDR CODE COMPLIANCE 'SolarCity I'D.W LISTED SolarCityy, January 2013 o January 2013 Reviewed By -� OPTIMUS SERIES:OPT 60 CELL MODULES . OPTIMUS SERIES:OPT 60 CELL MODULE Nigh-quality and high efficiency SunivaPV yields sensible solar L rho a,imoor<ol solo,erose simo^ B SUNIVA OPTIMUS" _ OPT)OU-604-1 B0(Zap Compatible frame) The OptimustlD modules consist of Suniva'S ELECTRICAL DATA(NOMINAL) latest technology:AR IisurO Select.These superior r van,a --2 W n rn.g!tI a m % monocrystalline cells are designed and manufaotured Power Classification Pmax(W) 255 260 265 in the U.S.A.using our proprietary krx�oost processing Module Efficiency q 15.71 16.02 16.33 techniques.Engineered with our pioneering ion Implantation technology,high power-density Model Number OPT 25540-4-1B0� 260-15D-4-11130-8 265bP4 180 6 Optimus modules provide exodent value. Voltage at Max.Power Point Vmp(V) 30.20 30.50 30.70 performance and reliability. Current at Max.Power Point Imp(A) 8.45 8.52 8.64 Certlrlcatlona: _ Open Circuit Voltage Voc(V) 38,1 38.3 38.3 Con > SMn Circuit Current IS.(A) 8.96 9.01 9.12 The elecrrcat dam apply to standard test conations(STC):Irradlanca of 1000 W1W with AM 1.5 spectra at 25'C. bv.la DIMENSIONS AND WEIGHT Cells/Module 60(6x10) Module Dimensions 1652 x 982 mm(65.04 x 38.66 in.) Module Thickness(Depth) 40 mm(1.57 In.) 1 Approximate Weight - -- - --- 18.5+/-025 kg.(40.8+/_0,5 Ib.)Engineering Excellence Feattires ... Quality CHARACTERISTIC DATA Of Solar Cell I High-efilclency Sunivae ARTlsun•Select monporystefline cells of 156 x 158 mm 6 in.) Frame Blade anodized aluminum alloy;Zap Compatible frame Glass Tempered(k>w4ron);anti-reflective Coating Junction BoxNEMA IP67 rated;3 internal bypass diodes Cable&Connectors 12 AWG(4 MnI cable with Amphenol H4 connectors;cable length approx.1200 mm TEMPERATURE COEFFICIENTS F`)0.L1Ce0 Voltage Q,Voc(16/'C) -0.335 Current a. 'Sc (%!'C) +0.047 Power y, 7 (%PC) -0.420 NOCT Avg (+/-2'C) 46.0 LIMITS Max.System Voltage 1000 VDC for IEC,1000 VDC for UL Operating Module Temperature -40'C to+85'C(-40'F to+185'F) Storm Resistance/Static Load' Tested to IEC 61215 for loads up to 5400 Pa(113 hail and wind resistant 'q C U P E R~i Sumve'reserves the right to change the Beta st eny time.V'ew iisWeffon marwel ar mpsole cmm.'UV 90 kWh,TC 460.bH 2000 ! x-0=1 ea anmoaararypeOPT66sNarhema Building Department a `cpoMMPPgPtlia OUR PRODUCTS: N amro ModukeMIlne CellsOPTIWUS 9ERIES 60 cell 19%-.1fipenry OPf1AUS SERIES 72 cell 57 �(�}7 IL c65 aesN ,� vm Yodul.9 as � al T° ce«V zusA FOR U O'. D, E 4...C ,41 MLWAWV S 60 061 .,O� M P L I A N C ERng Inverters.eaie En .1404 4T7 2700 Al SERIES 72 mI Stora.AI dEV CMgs 051413 (Rw.Z) n I reviewed B1' i