Loading...
13120190 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22059 MCCLELLAN RD CONTRACTOR:PIYUSH ROHATGI PERMIT NO: 13120190 OWNER'S NAME: PIYUSH ROHATGI 22059 MCCLELLAN RD DATE ISSUED: 12/23/2013 OWNER'S PHONE: 4084266620 CUPERTINO,CA 95014 PHONE NO: LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL ❑ COMMERCIAL ❑ KITCHEN REMODEL 200 SQ FT TO INCLUDE M,E,P'S License Class Lic.# Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$16000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35713024.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAFROM LA T CALLED IN7,--_t1VZ indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Datu with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. tlY OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this 4 permit is issued. Owner or authorized agent: Date: 4 11 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any mamier so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date _ CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildingCokupertino.org CUPERTINO ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROTECT ADDRESS •')�©5 C. APN#�n OWNER NAME 1 ` PHONE / E-MAIL' STREET ADDRESS 2_1(.)S5CGIs`��c.v� CITY,STATE,ZIP! 6 FAX CONTACT NAME P t Yu ` PHONE Lj oK 4 Z6 4 O E-MAIL STREET ADDRESS CITY,STATE,ZIPFAX e OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC H COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHTECVENGINEERNAME LICENSENUMBER BUS.LIC H COMPANY NAME E-MAIL FAX STREET ADMESS CITY,STATE,ZIP PHONE DESCRIMON OF WORK N,.1 pLW� msm= PROPOSED USE CONSTR TYPE HSTORIES USE TYPE OCC. SQ.FT. VALUATION($) E748TGrye( NEW FLOOR DEMO TOTAL ARSA (3� AREA AREA NET AREA BATURDOM KITCHEN OTHER Rt'JvfDUIM ARBA REMODEL AREA -T REMODEL AREA PORCH AREA DECK AREA TOTAL DECKIPORCH AREA GARAGE AREA: LJDETACH ❑ATTACH 4 DWELLING UMTS: IS A SECOND UNIT ❑YES SECOND STORY []YES BEING ADDED? No ADDITION? WO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES RECEIVED BY: TOTAL VALUATION: PLANNING APPL H []NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO ' 6J 1)0 0 By my signature below,I certify to each of the following: I am the property owner or authorized a Y.Tto act on the grope owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and it is accurate. I to comply with all applicable local ordinances and state laws relating to b Ing construction. I authorize representatives of Cupertino to enter e a ove-identified roperty for inspection purposes. Signature of Applicant/Agent: '� Date: LQ— L3 Zol SUPPLEMENTAL INFORMATION REQUIRED PL ECK TYPE ROUTING SLIP _New SFD or Multifamily dwellings: Apply for demolition permit for OVER-TRE COGNTER LDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Commercial Bldgs: Provide a completed Hazardous Materials Disclosure ❑ STANDARD ❑ PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWERDISTRICP submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2 011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 22059 mcclellan DATE: 12/23/2013 REVIEWED BY: Mendez APN: BP#: l aw 'VALUATION: 1$16,000 'PERMIT TYPE: Building PermitPLAN CHE TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION 1R3SFDREM USE: PERMIT TYPE: A WORK kitchen remodel 200 sq ft to include m e 's SCOPE .c,'.. Plan Cl.' L7«dr. Permit!' Plumh. Permit Fee: Flec. Perrrrit ree: Other,6lech.InspEF-1- Oilier Plumb Insp. Li 011ier Elee Insp. Mech.lmp. Fee- Plurnk Insp. Fee: EIec,Imp. Fee: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). Theseees are based on the prelimina information available and are only an estimate. Contact the De t or add"11 info. FEE ITEMS (Fee Resolution 11-053 E(1' 7/1/131 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = s.f. Remodel,Kitchen(<=300 sf) Suppl. PC Fee: (F) Reg. 0 OT 0.0 hrs $0.00 $626.00 IREMRESKIT PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Conswuction Tax. -7 Adinifistrative.Fee: Work Without Permit? 0 Yes O No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential O Travel Doccrrnentation Fees: Building or Structure � i Strong Motion Fee: IBSEISMICR $1.60 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: 1 $2.60 $626.00 TOTAL FEE-T $628.60 Revised: 10/01/2013 OWNER-BUILDER DISCLOSURE FORM COMMUNITY DEVELOPMENT DEPARTMENT- BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95D14-3255 (4D8)777-3228• FAX(408)777-3333- building(a cuoertino.org CUPERTIN0 Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SITE ADDRESS � I APN @P# OWNER NAME PI �( 05 H 20 . A T G L OWNER ADDRESS DESCRIPTION OF WORK: We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed,and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS: Please read and initial each statement below to signify you understand or verify this information.) q 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- Builder"building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. �/ 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for ,,�� the construction and are not hiring a licensed Contractor to assume this responsibility. VZ3. 1 understand as an"Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. %(/,/4.4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. V/5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"under state and federal law. k/ 6. I understand if I am considered an "employer" under state and federal law, I must register with the state and federal government,withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 07. 1 understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is pormed under contract with a licensed general building Contractor. ve 8. 1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction defects in the workmanship or materials. Oi+,nerBuilde-Foa7772010.doc remised 09/14/10 ► I understand I may obtain more information regarding my obligations as an "employer" from the Internal Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the Califomia Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or www.cs[b.ca.gov for more information about licensed contractors. fV 10. 1 am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the parry legally and financially responsible for proposed construction activity at the site address listed above. k_/ 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint.Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) hereby afnrm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: 2 Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's sianatur . Property Owner's Signature: DateY 10 12-312-01 3 --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE. The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): Project Location or Address: Name of Authorized Agent: Tel No Address of Authorized Agent: declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: Ow7ierBi(ildei-Foi771 1010.doc)-ei,ised 04114110 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION CITY HALL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 C U P E RT I N O (408)777-3228• FAX(408)777-3333 SCOPE OF WORK: Kitchen Remodel. Project shall comply with the 2010 California Building (Base code 2009 IBC), 2010 Residential (2009 IRC), Plumbing (2009 UPC), Mechanical (2009 UMC), Electrical (2008 NEC), Fire (2009 IFC) and Energy Codes (2008 Building Energy Efficiency Standards) EnergV code mandatory lighting measures: 1. All permanently installed high efficacy luminaires shall be switched separately from low efficacy luminaires. (150(k)(7)) 2. Permanently installed lighting in Kitchens shall be high efficacy luminaires. Up to 50% of the wattage of permanently installed lighting in kitchens may be in lights that are not high efficacy. (150(k)(8)) Plumbing plan notes: 3. Faucets in kitchens, wet bars, lavatories, laundry sinks, etc shall h e water flow not to exceed 2.2 gallons per minute. (CPC 402.1.2) ,rit Electrical Plan Notes: 4. The installation of smoke alarms in all of the following ar 11 be rovided: (R314.3) a. On the ceiling or wall outside of each separate,& epi ea in the immediate vicinity of bedrooms. b. In each room used for sleeping purposes 5. The installation of carbon monoxide alarms in t w g areas shall be provided: (R315.1) . a. Approved carbon monoxide alarms shall b` nstalled outside of each separate sleeping area in the immediate vicinity of the bedrooms and on every level including basements in dwelling units that have fuel-fired appliances or attached garages. 6. A minimum of two 20 amp small appliance branch circuits shall be provided for all receptacle outlets in the kitchen, dining room, pantry, or other similar areas. (CEC 210.11(C)(1)) 7. In every dwelling unit, fixed appliances such as food waste grinders, dishwashers, washing machines, dryers, laundry tray locations, built-in refrigerators or freezers, furnaces, AC units, built-in heaters or any other fixed appliance with a motor of'/ h.p. or larger shall be on a separate 20 amp. branch circuit. 8. All receptacles in bathrooms, garages, accessory buildings, outdoors, crawl spaces, unfinished basements, kitchens (where receptacles serve counter top surfaces), laundry, utility, wet bar sinks (within 6 feet of the edge of the sink), shall have ground-fault circuit interrupter (GFCI) protection. (CEC 210.8) 9. In all areas specified in 210.52, all 125-volt, 15-and 20-ampere receptacles shall be listed tamper-resistant receptacles. (CEC 406.11) `J SCOPE OF WORK 1. DEMO EXISTING KITCHEN AND NON STRUCTURAL WALLS 2. CANCEL BAR SINK, INSTALL FRIDGE WATER LINE s 3. MOVE WALL REGSITER 2 FT 2 X 8 CEILING 4. INSTALL NEW KITCHEN CABINETS AND COUNTERTOP 4 X12 HEADER JOIST SCALE 3/8" = 1 FT 5. INSTALL TITLE 24 RECESSED LIGHTS (E) 24 OC. CD 6. REPLACE OVERCOUNTER OUTLETS WITH GFCI 4 X 12 I 7. RUN 2 RANGE GAS LINE FROM EXISTING 4 GAS PIPE HEADER, (E) 8.REPAIR WOOD FLOORS BY OTHERS. 9.TEXTURE AND PAINT LOCALLY 4 X 4 POST GENERAL NOTES KITCHEN REMODEL 1/2 FRIDGE SUPPLY LIN (N) 4 (E)) 3 GAS LINE �,. ......., 1. CONTRACTOR SHALL VERIFY ALL DIMENTIONS 1. UPGRADE ALL EXISTING RECEPTACLES TO BE 4 D AND ELEVATIONS PRIOR TO CONSTRUCTION. PROTECTED WITH GFCI(S) (E)) 2. ALL FOUNDATION CONCRETE SHALL HAVE AN 2• THE SERVICE PANEL MUST BE UPGRADED TOA ULTIMATE COMPREHENSIVE STRENGTH OF 2000 MINIMUM 100 AMPS. 4 IN H C O N C, PSI IN 25 DAYS. ', SLA (E) 3. ALL MUDSILLS SHALL BE PRESSURE TREATED 3. A RECEPTACLE OUTLET SHALL BE INSTALLED AT DOUGLAS FIR OR REDWOOD. EACH WALL COUNTERTOP SPACE THAT IS 12 4. ALL FRAMING LUMBER SHALL BE D.F.N0.2 OR INCHES OR WIDER. RECEPTACLE OUTLETS SHALL N I BETTER UNLESS NOTED ON THE DR. BE INSTALLED SO THAT NO POINT ALONG THE 5. ALL NAILINGS SHALL CONFORM TO 2010 CBC WALL LINE IS MORE THAN 24 INCHES MEASURED ANC L BAR SINK TABLE NO.2304.9.1. HORIZONTALLY FROM A RECEPTACLE OUTLET IN / THAT SPACE.AND SHALL BE LOCATED ABOVE, BUT 6. MAX. STUD NOTCHING FOR EXTERIOR AND NOT MORE THAN 20 INCHES ABOVE THE S Sv9 ( SdJ BEARING WALLS IS 25% OF STUD WIDTH. ( 1/2 AS LINE (N) 7. SLIDING GLASS DOORS AND WINDOWS SHALL COUNTERTOP. I BE CERTIFIED AND LABELED TO MEET AIR 4. OUTLET BOXES SHALL BE INSTALLED SO THE D cl :...:. INFILTRATION STANDARDS. FRONT EDGE OF THE BOX, PLASTER RING, I I ;. (E)18/ /X26/1 GRADE B E��i, 1=1/8 AND WINDOWS SHALL BE WEATHER EXTENSION RING, OR LISTED EXTENDER WILL NOT W/2-#4 @ T&B W/#3 V� •.:- , 8. ALL DOORS A � � ::•.,.- ,• A STRIPPED; EXTERIOR WALL JOINTS AND 5. BE SET BACK OF THE FINISHED SURFACE MORE PENETRATIONS CAULKED AND SEALED. THAN 1/4". @18 D.C. 9. PROVIDE FOUNDATION VENTILATION OF (1) M SQ.FT. PER 150 SQ.FT. UNDER FLOOR AREA PER 6. INSTALL TWO OR MORE 20-AMPERE SMALL D SECTION A-A APPLIANCE BRANCH CIRCUITS FOR ALL CV 2 X8 C E I L DEMO CLOSET NON BEARING CBC SECTION 1203.3 RECEPTACLE OUTLETS FOR THE SMALL 10. PROVIDE ATTIC VENTILATION NOT LESS THAN APPLIANCE LOADS(INCLUDING REFRIGERATION �' JOIST TNP WALL,LOCAL CLOSET DDDR -.-- - 1/150 OF THE AREA OF THE ATTIC PER 2010 CBC EQUIPMENT)IN THE KITCHEN, DINING ROOM, p SEC.1203.2. PANTRY, BREAKFAST ROOM, ELECTRIC CLOCK 2 4 ❑C (E) 11. PROVIDE INSULATION BLOCKS AT EAVE RECEPTACLE,AND ELECTRIC LOADS ASSOCIATED 0 VENTS. WITH GAS FIRED APPLIANCES;BUT THESE Q O 4' CONC. LAB � � 12. PROVIDE TEMPERED SAFETY GLASS AT CIRCUITS ARE TO HAVE NO OTHER OUTLETS. SCALE 3/8 = 1 FT cup EXTERIOR SLIDING GLASS DOORS AND 7. PROVIDE SEPARATE CIRCUITS FOR THE GARBAGE thlinnT'J . INTERIOR SHOWER ENCLOSURES. 5�. Fg � ert� DISPOSAL AND THE DISHWASHER. PIYUSH ROHATGI , �tM�,., � �> , 13. PROVIDE CEMENT BOARD BACKING AT TUB AND SHOWERTILE AREAS PER CBC SEC. 2500.2. 8. BRANCH CIRCUIT CONDUCTORS SUPPLYING r;� CL 14. ALL SKYLIGHTS SHALL BE ICC-ES APPROVED. RANGES,OVENS AND OTHER COOKING RevfeWecy ev �C()MP IA/V 15. ALL DETAILS,TRIM & FINISHES ARE TO MATCH APPLIANCES SHALL HAVE AN AMPACITY RATING 2 X8 CEILING RESIDENCE EXISTING UNLESS NOTED ON DR. OF NOT LESS THAN THE MAXIMUM LOAD SERVED. 16. FLOOR AND INTERIOR FINISHES ARE TO BE FOR RANGES 8%KW OR MORE RATING,THE JOIST SELECTED BY OWNER. MINIMU 4 X 12 HEADER A D E RRANCH-CIRCUIT RATING SHALL BE 40 2 4 ❑C. (E) 17. SMOKE ALARMS IN AREAS OF NEW AMPERES. CONSTUCTION TO BE 120V WITH BATTERY (E) BACKUP AND INTERCONNECTED. NEW SMOKE 9' PERMANENT LIGHTING INTERNAL TO CABINETS l ALARMS IN EXISTING CONSTRUCTION MAY BE SHALL NOT USE MORE THAN 20 WATTS OF POWER � 100 1 2 PER LINEAR FOOT OF ILLUMINATED CABINET. SOLEY BATTERY POWERED PER CBC SECTION SCALE F = 1 FT r 907.2.11.1. 10.RECESSED LIGHTING IN INSULATED 18. EXHAUST FANS AND FAN SYSTEMS SHALL BE CEILINGS MUST BE RATED FOR DIRECT PROVIDED WITH BACKDRAFT DAMPERS. INSULATION CONTACT(IC),CERTIFIED AS `----��- TEL 408- 426- 6620 19. SLOPE FINISH GRADING AWAY FROM BUILDING AIRTIGHT CONSTRUCTION (AT),AND MUST HAVE A 5% MIN. SEALED GASKET OR CAULKING BETWEEN THE 20. CONTRACTOR SHALL BE RESPONSIBLE FOR HOUSING AND CEILING ( ( I I ( I I I ( ( I ( I VERIFICATION OF THE SIZE AND LOCATION OF 11.ON THE DISCHARGE SIDE OF THE SMOKE ALARMS-CRC314 22059 M C C L E L L A N RD ALL EXISTING UTILITIES ON AND OFF SITE. DISHWASHER PROVIDE A LISTED AIR GAP FITTING INSTALL SMOKE ALARMS IN EACH SLEEPING ROOM I 4 X 4 POST ( 1 I UTILITY DATA MAY BE INCOMPLETE AND INSTALLED WITH THE FLOOD LEVEL(FL)MARKING OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE LOCATIONS SHOWN ON PLANS ARE AT OR ABOVE THE FLOOD LEVEL OF THE SINK OR VICINITY OF THE BEDROOM (E)) I I C U P E RT I N O, CA 95014 APPROXIMATE AND ARE FOR GENERAL DRAIN BOARD WHICHEVER IS HIGHER. INFORMATION ONLY. AND IN EACH ADDITIONAL STORY OF THE DWELLING INCLUDING 12.VERTICAL CLEARANCE ABOVE COOKING j X 10 A'B. crI TOP. HOUSEHOLD COOKING APPLIANCES SHALL BASEMENT AND HABITABLE ATTICS @48 0,C. (E) ISSUE HAVE A VERTICAL CLEARANCE ABOVE THE CARBON MONOXIDE ALARMS - CRC 315 COOKING TOP OF NOT LESS THAN THIRTY(30) MARK DATE DESCRIPTION INCHES TO COMBUSTIBLE MATERIAL OR METAL INSTALL CO ALARMS OUTSIDE OF EACH SEPARATE DWELLING UNIT CABINETS.A MINIMUM CLEARANCE OF SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS; I 12/23/13 PERMIT SET TWENTY-FOUR(24)INCHES IS PERMITTED WHEN: AND ON EVERY LEVEL OF THE DWELLING UNIT INCLUDING A METAL VENTILATING HOOD AT LEAST AS BASEMENTS. WIDE AS THE APPLIANCE AND IS CENTERED • • r r:• r •: . r.. r •• .• OVER THE APPLIANCE.(OR) .' we �':• •4 :•4;. A LISTED COOKING APPLIANCE OR %f �- G C ) 18'/X26" GRADE BEAM -- J m,,, MICROWAVE OVEN IS INSTALLED OVER A ' '�''•'••• ••�' j •• 4 ` • ' ' • '•• ' ' ' • " •• •` LISTED COOKING APPLIANCE INSTALLED PER D ! W/2-#4 @ T&B THE MANUFACTURER'S INSTRUCTIONS. I E 94--_�_-2.7.13.EXHAU5T DUCTS SHALL TERMINATE -- 2'7 .....1� - 36 3/4 -t- ' SECTION 13- 13 OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH A BACK-DRAFT DAMPER. (E) i GFCI (E) (E) GFCI (E) 1 M (E) -_----------------________ _-----_ ___-- ----___--- ----_---------_______---_� ____-- -__--------_---_-__ -.__ PROJECT NO: 001312358 � f------- N) --`--N rr; GF� LEGEND DATE: RESIDENTIAL KITCHEN REMODELS -2010 5 10 15 20 25 (N) "Z"'f�i' t ! n/ n, CFL TITLE 24 COMPLIANT 6" RECES��4 blid T�I� =; °� "°`r � 1/8" = V-0A o _nllNO J 1. ALL COUNTER RECEPTACLES SHALL BE GFCI PROTECTED, APPLICABLE CODES ark, j SCALE: 1/8" = 1'-0" TAMPER-RESISTANT (TR)AND LOCATED SO THAT NO POINT IS MORE CBC 2010 CMC 2010 CPC �- �" �' °' ? , « � �� <�¢�I : �<4' " __ - o� V < -�.,�'��.( r���{€�,� DRAWN BY: S. SIMON THAN 24 FROM A RECEPTACLE OUTLET. COUNTER TOP AREAS WITH -�}- WALL MOUNT SWITCH .rr�l a rf 2010, CEC 2020, CRC 2010 ur - 71� ��;t� t� �,' CHECKED BY: u A MINIMUM DIMENTIONS OF 12 IN WIDTH SHALL BE PROVIDED WITH A C!''i`v vti'1, LS{IE I iJZar4 ,,..� fC1 th2 U(1 '; a n . RECEPTACLE. RECEPTACLES SHALL BE LOCATED NO MORE THAN 20" AND ALL CUPERTINO CITY ° "I'f ..fal. APPROVED BY: Y. ZENG 3 I' f;� , a �,fls a�i� r , , .< o ABOVE COUNTER TOP MEASURED HORIZONTALLY ALONG THE WALL. (N) BYLAWS tN) HVAC REGISTER r; �y at � T a a t, ., ISLANDS/PENINSULAS SHALL HAVE AT LEAST ONE RECEPTACLE. ^� ___o ® i �� of -,Icy or 4+to uiv, 2. COUNTERTOP RECEPTACLES SHALL BE SUPPLIED BY A MINIMUM OF (N) y w :, G1 G ! SHEET TITLE TWO 20-AMP BRANCH CIRCUITS. ` 3. GARBAGE DISPOSAL, DISHWASHER, EXHAUST HOOD, AND BUILT-IN (E) E EXISTING �� o t312.61�o MICROWAVE MAY REQUIRE DEDICATED CIRCUITS BASED ON THE (N) MANUFACTURER'S REQUIREMENT AND MOTOR RATING. GFCI (E) (E) - DW(E) T GFCI DUPLEX OUTLET 4. A MINIMUM OF 50% OF THE TOTAL RATED LIGHTING FIXTURE WALL MOON G C GFCI KB WATTAGE (BASED ON THE MAXIMUM ALLOWED FOR EACH FIXTURE) T GFCI 1001 SHALL BE FLUORESCENT. THE "RESIDENTIAL KITCHEN LIGHTING e WORKSHEET" SHALL BE COMPLETED AND PROVIDED TO THE �N} NEW BUILDING INSPECTOR AT THE ROUGH ELECTRICAL INSPECTION. 58 1 /Z 117 3/4 THIS DRAWING IS 24" x 36" AT FULL SIZE 5. SMOKE ALARMS SHALL BE PROVIDED IN ALL SLEEPING ROOMS AND 42 __ ...._._.... __---.... _._.._._. _......._ _.._........... _- _.... _.............. ADJACENT HALLWAYS, MULTI LEVELS, AND BASEMENTS. CARBON .....__........ MONOXIDE ALARM SHALL BE INSTALLED IN HALLWAYS ADJACENT TO 1 DEMO NON -LOAD BEARING WALL BEDROOMS AND EACH LEVEL. SCALE2" = 1 FT SHEET OF