14010018 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21430 MILLARD LN CONTRACTOR:CLEAN SOLAR PERMIT NO: 14010018 OWNER'S NAME: WILLIE WANG 1445 KOLL CIR STE 109 DATE ISSUED:01/06/2014 OWNER'S PHONE: 4088403165 SAN JOSE,CA 95112 PHONE NO:(408)217-8876 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL ❑ 25 ROOFTOP,FLUSHMOUNTED PV PANELS,6.25KW& License Class Lic.# 'AJO&� ADD Contractor C.�f3 '510L—P+ Date f / SUB PANEL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$32571 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32644055.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is PERMIT EXPIIZES IF WORK IS NOT STARTED correct. 1 agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FRO LED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, — costs,and expenses which may accrue against said City in consequence of the granting of this permit. ill pally,the ap ant understands and will comply sued by: `"Hate!—� with all non int sour reg u s per pertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date f All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay AM Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cu tin u . pal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 505, a d 5534. Section 3700 of the Labor Code,for the performance of the work for which this j b Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to die Worker's Compensation provisions of the Labor Code,I must 1 hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the l understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION O� COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION `O 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 ` ` O (408) 777-3228• FAX(408)777-3333•building(d)cupertino.org \ CUPERTINO PROJECT ADDRESS Z APN H � OWNER NAME W�L1.�( Ski2 � PHONE C � lbs TIM AIL kDR2STREET ADDRESS 21'i3� M�t.VR2,D L� CITY, STATE,ZIP FAX CA 9!5(7 1 CONTACT NAME ED 5.1-� ? PHOpEQ�_ I _7 ICS,Z E-MAIL D C CZ)"AA_ " A ,�M STREET ADDRESS a, 3 ----', CITY.STATE. ZIP FAX J Yc I ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR X CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS,LIC N Cil. `b0 1 O(6C Lo C" COMPANY NAME E-MAIL IA 4Q,& N c? Gt.C-�Prf�� +-• GoM `� 21 1p c(s�8 STREET ADDRESS ITE too, C1TY,STATE,ZIP S fDSE �1 7 PHONE Sid& -� ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC N COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF SFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes NO FLOOD ZONE ❑ Yes NO SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER' FOR SO1_4R PANE1_V: NUMBER OF PANELS/UNITS: N KILOWATTS: T TAL VALUATION 25 (1.Z5 kW DESCRIPTION OF WORK ga�>FTOpJS+IN�U BY: ` By my signature below,I certify to each of the folio n am the rty owner or authorized agent to act on t operty owner's b 7eread this application and the information I have provided is orr c. hav the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building c str, t' I ze representatives of Cupertino to enter the ab�e-clent`ied property for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY VER-TFIE-COUNTER a Y F' ❑ EXPRESS U U ❑ STANDARD U U a ❑ LARGE c ❑-MAJOR PVApp_2012.doc revised 06/20112 CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 21430 MILLARD LN DATE: 01/06/2014 REVIEWED BY: MELISSA APN: 326 44 055 BP#: 'VALUATION: 1$32,571 rPERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK 25 ROOFTOP FLUSHMOUNTED PV PANELS 6.25kW &ADD SUB PANEL SCOPE Llrch. Plan Check Plumb, Plan Check Elec.Plan Check 0.0 hrs $0.00 Tech.Perwil Fee: Plumb. Pe w+rt Elec.Permit Fee: IEPERMIT Other Meuh,Insp, Oilier Plumb Insp Other Elea 0.0 Insp. hrs $47.00 Akch.fnsp.Fee: Plumb. haj).Fee. L:lcc.Insp.Fee: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). These ees are based on the prelimina information available and are only an estimate Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 1 # Alternative Energy System Suppl. PC Fee: (j) Reg. Q OT 0.0 hrs $0.00 $229.00 IPHOTOVRES I Photovoltaic System PME Plan Check: $0.00 100 1 amps Electrical Permit Fee: $0.00 $47.00 IBELEC200 Services Suppl. Insp. Fee-.0 Reg. Q OT 1 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $47.00 Conso-uction Tax., T I Administrative Fee: !ADMIN $44.00 0 Work Without Permit? 0 Yes (E) No $0.00 E) Advanced Planning;Fee. $0.00 Select a Non-Residential Traveli Documentation Fee: ITRA VDOC $47.00 Building or Structure 0 Strong Motion Fee: 1BSEISMICR $3.26 Select an Administrative Item Bldp,Stds Commission Fee: 1BCBSC $2.00 .. � SUBTOTALS: $143.26 $276.00 TOTAL FEE-T $419.26 Revised: 10/01/2013 CLEAN Notes � � ��� SOLAR INC. Project Description f = s 1) This drawing is diagrammatic in some respect. Field verify exact conditions prior to beginning work r 1 Modules: 25 Canadian Solar CS6P-250M modules 2 Electrical run is a uroximate and will be determined in the field by our electrical installerszti 1445 KOLL CIRCLE O ) ` surrE 109 2) Microinverters: (25) Enphase M215-60-2LL-S2x 3) Some roof details omitted for drawing clarity h a 4 k San Jose CA.95112. 3) Monitoring system with Microinverters 4) System built per 2013 California Electrical Code 690 A. ' frn l .:t 4 Standard components include; racking and 5 Conduit runs over roof N. - k rn k Y Cont:. Lic # 910849 mountingcomponents,, wiring, conduit, and overcur- 6 36" ride & 18" hi valle setback & No AC disconnect required for the Ci of Cupertino P 9, ) @ 9 @ hip/valley q City p rent protection, roofing sealant or flashing, as needed ;i� �a ;, - �, 4, � � � t `� www.cleansfllar.com 5) No battery back-up systems STRUCTURAL CALCULATIONS i 6} Main electrical panel, inverter and controller panels ' Property line .� cbr t ` }fid will be labeled with warning labels Weight System Totals Point Loading ' 7) All Metal parts of module frames, equipment and conductor enclosures will be rounded 1047.5 lbs Modules 1370.5 lbs Total Array ` , " '�� � � CIEANSOtAR gy 8 All outdoor wiringwill be weather rated 88.0 lbs Mounts 44 Loading Points �� � '` " °x,ft ' ' 125.0 lbs Racks 31.15 lbs/Loading Points re '' mw 110.0 lbs Microinverters MAIN SERVICE PANEL LABEL: a _U Y "CAUTION• SOLAR PV SYSTEM Canadian Solar CS6P-250M M '� °� �` ' ems` '' E s. m.1: y r `d ,� r r ? W 1370.5 lbs Total Weight Module Dimensions: 64.5"x 38.7"x 1.57" r t INSTALLED. WHEN POWER 433.3 sq ft Array Module Weight: 41.9 lbs cn Ln DISCONNECT, lbs/sq > t �- 3.16 lbs sq M u e Area: 17.33 sq SOLAR PANELS AND WIRING IN CONDUIT MAY REMAIN ENERGIZED." PROJECT VALUATION `_ ®- Gas bond Total Value of Project: $32,571 SITE MAP LU O � #4 GEC connected SYSTEM SIZE RATING F- 8' to (E) UFER GE rod STC rated: 6.250 kW LABELS o Front CEC-AC System Rating: 5.470 kW Labels will be Weather Resistant Red 3 with White Lettering Azimuth: 900 1800 2700 MAIN SERVICE PANEL 2 1st story1. AC Solar Input Breaker. Do not relocate this Roof slope. 250 breaker, UI I 1st story 1st story2. WARNING - Dual Power Sources. (N) Electrical runs over roof, Second source is photovoltaic system �. penetrates eave, then runs 3. WARNING - Electric Shock Hazard DO NOT *� to (N) ACLC & (E) MSP onTOUCH. TERMINALS on both Line and Load Ln external wall sides may be energized in the Open Position. M Cement S Tile roof LEGEND 4. CAUTION - Solar PV system installed. When Z U MSP Main Service Panel power disconnect, solar panels and wiring in Ln Q &Utility Meter conduit may remain energized. d" m '�5�, 2nd story ACLC AC Load Center '. �-+ Ln r- �B Junction Box 5. Max AC Operating Current: 22.50 A . „ LU ,y --� Operating Voltage: 240 V —� w M Enphase Microinverters � � L� O L JUNCTION BOXES ~ D d- 7 ,� Mountings are _ t0 ide Wndstory Side �� max 4 - 6 feet apart 1. WARNING - Electric Shock Hazard. � , 00 r- �� 2nd story Conduit Run No user serviceable parts inside. a C o �- 74 Contact authorized servicer for assistance. M O 'y p © Chimney ��� 2. CAUTION - Solar PV wiring may remain � r t 1r, �, 1t APPLY THIS LABEL TO ALL 0 A;; rrAuAding Electrode energized ized after disconnection Burin da Il ht �.., Zi r- r- 275 70 O �,,�,�.,,,, 9 9 daylight FUNCTION BOXES: E ?,�,, �h\rFR ��t`a t .t p,lC2Y��.,n G � hours. r C„) Q, "CAUTION: SOLAR PV v� ,� RACEWAY ro WIRING MAY REMAIN g ��r�c �` u' �' 1. CAUTION - Solar Circuit ENERGIZED AFTER 2. Apply this label to Conduit every 10 feet: 87" �b �0•, DISCONNECTION �? ��G`''`G `` ;� aGi4 'PHOTOVOLTAIC POWER SOURCE' 1 = 9.0 DURING DAYLIGHT HOURS" ItP AC LOAD CENTER f � � 1. CAUTION - Photovoltaic AC Disconnect (N) Array: (2) Canadian Solar SCALE : 220" 235 ' CS6P-250M modules Prope ` n� ` r` 2nd story (N) Array: (10) Canadian Solar DRAWN BY CS6P-250M modules CUPERTINO ' Istvan D Szabo Building Uer)artmen REVISION BackP1,0T PLANS REVIEVVED FUR CURE GOMPLIANC o��� � �I� �� �� �� ISSUE DATE: (N) Array: (3) Canadian Solar kevie Vea g , Dec/2-4/2013 CS6P-250M modulesDEPT. `'- G• (N) Array: (10) Canadian Solar Property line DAT9, SHEET" NO. CS6P-250M modules Property line 01 CLEAN � } EMBEDMENT DIAGRAM 25 Legend Modules: Canadian Solar CS6P-250M modules SOLAR INC. QUICKMOUNT PV UNIVERSAL TILE MOUNT 1) Modules: (25) Canadian Solar Roof Type - Cement S-Tile KOLL CS6P-250M modules Racking is 3"- 6" above finish roof 1surm 44509 CIRQE Hanger bolt 5/16 x 6" Min. 2.5" embedment 2) Microinverters: (25) San Jose CR.95112. Enphase M215-60-2LL-S2x QuickMount PV Universal Tile mounts cont, Lic # 910849 3) Roof slope @ 250 5 4) Roof decking - Plywood 15" overhang @ eave www.cleansolar.com 5) 48"-72" max spacing between roof mounts 6) QuickMount PV Universal Tile mounts 2"x 6" @ 24" rafters r-- _ 7) Black IronRidge XRL rails ,t , `- - 8) Rafters 2"x 6" @ 24" 2 x 4 purlin CCEA LAR r--- NSO Ifl L- - `. r-- 2"X 4" @ 72" props r-- 1 L W r- r- - I- - , 2"x 8" ridge beam LO r-- - -; 2"x 4" @ 48" windbraces 1 1 , 1 , t 1 1 1 , �1 - External wail ® � r-- L 1 1 1 3 SECTION - SIDE VIEW 0 b 1 1 1 , 1 L__.I L__3 L--JCL L-_J 1 1 I 7 6 8 4 MODULE LAYOUT - ROOF DETAIL PLAN c:) Ln 36" @ ridge & 18" @ hip/valley setback required o' - Z U Uj� ® Racking is 3"- 6" above finish roof _ r Ln 2"x 8" ridge beamC-i _' M � Cd 6 ---_ __ U J. U 0`t0 U J N 21?x 4" purlin 211x 4" @ 72" props SCALE 211x 6" @ 24" rafters DRAWN BY : OUPERTINIstvan D Szabo 2"x 4" @ 48" windbraces `' --- ,�"�` � �I;gilding DpPatm np REVISION ISSUE DATE: Dec/24/2013 Load Path SHEET NO. Solar modules supported by IronRidge XRL rails, supported by standoffs, supported by 2"x 6" @ 24" rafters, om"' 2 2"x 4" @ 48" windbraces, 2"x 4" @ 72" props, supported by exterior walls CLEAN SOLAR INC. Amperage Calculation for 1445 KOLL CIRCLE CS613-250M modules Sano109 San Jose CA.95332. L_�,-----Microinverters: (25) Enphase M215-60-2LL-S2x cont. Lic # 910849 Individual Modules (DC) www.cleansolar.com Pmax 250 W Vmp 30.40 V � Imp 8.22 A71—Modules: (25) Canadian Solar CS6P-250M modules IV Voc 37.50 V CLEANSOLAR Isc 8.74 A Individual Inverter (AC) Vop 240 V w Z Iop 0.90 A #12 xHHW-2 AC BUS H H Ll Ll U -H--U U--U-- H H Ll H (under modules) L 'A' (15)Inverter BranchAl A2 A3 A4 A5 A6 A7 A8 A9 A10 All Al2 A13 A14 A15 Z Vop 240 VAC ® -j Iop 15 x 0.90 = 13.50 A > J Iop max 13.50 @ 125% = 16,88 A Q -j #12 xHHW-2 AC BUS JB r Ln 'B` (10) Inverter BranchLJ H H U --L[- -0U � Ln modules) Vop 240 VAC Iop 10 x 0.90 = 9.00 A 131 132 133 134 135 136 137 138 139 B10 Iop max 9.00 @ 125% = 11.25 A #6 solid copper ground Ln ZUj V Ln q Ln .- Uj J LU M O 0C U 0 Nr CanadianS0.41ar . � ® (E1 t1TILITY (E) MAIN CD (N) AC LDAD CENTER. a. BONDING METHOD UGC-1 clips + WEEBlug 6.7 METER SERVICE HOM612L100RB ( J Bi-directional PANEL owl Used in conjunction with SolarMount rails from , 100 amps UhERHN1P &E Bryant UNIRACno hole is requested (INTERTEK certified). 80ding Derpar e; Y r � M UGC-1 grounding clips are used to create grounding 125 A rated , r path between the module frame and the UNIRAC rail. - = ; N WEEBlug 6.7 assemblies are designed for use with size OR CODE CC?MPt-,, � '; 6-12 AWG solid copper conductor wire, and allow 000 connecting the system to equipment ground connector. °cam° No Main Breaker --,. WEESUS SCALE UGC-1 40 A to existing loads DRAWN BY : General Notes: x Istvan D Szabo To E S b O 20 A 1. 240V AC wires run from array to service UTILITY 40/40 A GRID REVISION. panel breaker. 120/240V Quad 15 A Refer to the latest SolarMount Rail System installation single phase ISSUE DATE: 2. individual modules inverted from DC to AC manual from UNIRAC or to UL-SM En AO Technical Dec/24/2013 with microinverters located under each note from Canadian Solar for more information. Always module. follow safety procedures when installing any mounting o #4 GEC connected to SHEET NO. 3. #10 wire sized for 0.34% voltage drop system. Failure to follow SolarMount Rail System latest (3) #8 THWN-2 wires (6) #10 THWN-2 wires regulatory instructions will void Canadian Solar Inc. (E) LIFER GE rod over 60 feet @ 240 volts. (1) #8 THWN-2 ground (1) #8 THWN-2 ground module warranty. 3 3/4" EMT conduit 3/4" EMT conduit CLEAN SOLAR INC. INVERTERS SPECIFICATION SHEETS 1445 KOLL CIRCLE SUITE 109 San lose CA.95112. • OINV - . - M215 - MICROINVERTER TECHNICAL DATA Data r .t Cont. Lic # 910849 Recommended input power(STC) 190-26OW Mwdmum input DC voltage 45V www.cleansolar.com Peak power tracking V01-age 22V-36V > it Operating range 16V-36V Min./Ma:cstart voltage 22V/45V Max DC short Circuit current 15A Max input current 10.5A Ic WSW ® r +• Maximum output power 215VJ 215W CL EANSOLAR Nominal output current 1.0A(arms at nominal duration) 0.9A(arms at nominal duration) z k Nominal voltage/range 208V/183-229V 240V/27'-264V 4r Extended voltacelrange 208V/179-232V 24OV1206-269V ` " a Nominal frequency/range 6U.0/5Y.3-W.5 Hz 60.U/59.3-W.5 Hz r ,.t Ra �g'-''�:.. Extended frequency range 60.0/59.2.60.611z 60.0!59.2-60.611z Power Factor >0.9s >0.95 Maximum units per 7.0A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak,'.74ms duration W _} CE C weighted efficiency 96.0% Z Peak inverter efficiency 96.3% Static MPPT efficiency(weighted,r&erence ENSOMD) 99.6% 0 Dynamic MPPT effic ency(fast irradiation changes,reference EN505M) 99.3% U t--•t Night time power consumption 46mW ~� -Maximum energy production _ r The Enphase Energy Microinverter PRODUCTIVE -Resilient to dust,debris and shading J � -Performance monitoring per module Ambient temperature range AWC to+65"C System improves energy harvest, 0 [--IOperating temperaNrc rangy_(internal) -40°G to+85•C increases reliability,and dramatically -System availability greater Weighsions(WxHxD) 17.3 g(x 16.4 an x 2.5 cm(6.8"x6.45"x 1.0")' 0 ,` ' RELIABLE[ than 99.8% Weight Na kg(3.S lbs) � fQJ_ simplifies design,installation andtooting Natural convection-Nofans -No single point of system failure management Of solar power Systems- Enclosure envircnmental ratng Outdoor-NEMA 6 'witaout mounting bracket 0 Features The Enphase System includes the -Quick and simple design,installation SMART and management Compatibility Pairs with most 60-cell PV modules microinverter,the Envoy Communications -24/7 monitoring and analysis Communication Power line Warranty 25-yaar limited warranty Gateway,and Enlighten,Enphase's Monitoring Free lifetime monitoring via Enlighten software monitoring and analysis software- -Low voltage DC Compliance UL1741AEEE1547,FCC Part 15 Class B SAFE -Reduced fire risk CAN/CSA-0222 NO.0-M91,0.4-94,and 107.1-01 Enphase Energy,Inc. 201 1st Street S ® Petaluma,CA 94952 Phone:877-797-4743 G US Fax:707-763-0794 Nr info@enphaseenergy.com http://www.enphase.com 142-00010 Rev 03 vim{ Ln (� t� V Z Ln Q NODULES SPECIFICATION SHEETS � � LU ) z Ln 11.0 Canad>ranSolar - y Nommat Maximum Power(Pmax) 230'd7 235W MOW 245W� 250V1 §+ t" .^ a "?kir 3"`�'' 'dX U W Oparat ngVohage(Vmp) 29.9V 30.1V 30.2V 30.3V 30.4V �, Pmax 0,45'rrC �'" +�,- (r/�) Optimum Operating Current(lmpj 7.70A 7-S2A 7.95A S.WA 8.22A 7 p lure ConfO6-t Voc 0.35 X11L' _ .6 _I _ All-black C 6P Open C rcuit Volta a lVocj_ 37.1V 37.2V 37.3V 37AV 37XV py1 0.060 rOWN0 Yd ' short C muil Curren[(Isc) 8.22A 8.34A &46A S.61A 8.74A al Operat iiCeOTemperatur p5+ ya f x�� 2 4Z 1 O r r Module Efficiency encY 14.30X 14.61% 14.92% 1J.23% 15.54%_ sr'z}. g,"'. •••d pV}• 230/235/2401245/250M � �i Operating Temperature -40C-.857Ct 'TS r " Maximum System V h.ge �p, V t000V tEC /600V UL Maximum Sales FusaRating 15A '}5�+��`� Application Classification Clas.A { f4. y ""'rfis s ; U Poway Tolerance 0--sw "s .. -... ,. +x .afi'ss ..sf•� - -. .. .a -r spa � r t r All-purpose Module a �3 . . z ' MEMO NNW @01MIN EMEM AI!-black CS6Pis arvbust all purpose soler Paw r(Pmax) 166w naw +73w 177w taow module with 60 solarcells.Thesemodules w Optimum Operat ng Vohage(Ymp) 27JV 27.SV 27.SV 27.bV 27.7V �Y T2 M Optimum Operating eumint(Imp) 6.39A 6.18A 6.29A 6.40A 6.S1A P C» can be used foron-grid and off-grid solar a �t�G a V rcuil Vulta9e(Vuc) 34,9V 34.1V 34,2.V 36.3Y � q f applications.Thealt-black modules use high efficiency mono-crystalline cells, ,' ,v`<{ Short C rcuilcurient(Isc) 6.65A 6.75A 6ASA 6-97A ��» �t laminated with black backsheet and framed " r z ? with black anodized aluminum.The all p modules arethe perfectchoice efcustomers r„ ( & who notonl are keen on vain solarener sP t tCellType Mono-crysta16ne 156 x 156mm,2or3 Busbars sa,£ y? Y 9 gy, ",'. : Ce1lArrangemenl 6016x10) txr�� )• r a r but alsolook for aesthetic value. sa r a.".t Dimensions 1638x982x40mm(64.sx38.7xl.57in) � 3 wagnt 20kg(44-1 lbs) 3.2tmn Tempered Utas Applications ppcaons : SYjt Frame Maleval Anodized elummiuma0oy ,�. T. • On-grid and off-grid residentialroof-tops 14 i sox IP65,3 diodes - - 1 - On-grid and off-grid cammerclaUtndustrlalg� cacta 40707=OE_ c)I1znwG(ut.).11oanm roof-tops seoaneatnrs MctorMucamparaWe !" .; J'/� Rural area applications Standard Packaging(Madulasper Pallet) 24pcs Sl.d'1LE , v'd `*. l _ Y. '*` =3(``. • Solar power stations 8 (R,F ` Module Pec sper container contaner(40ft.C.mtaisne) 672p-(4gHQ) Other on-grid and of-grd applications ,. a0 `3ak tsVi. 1 r Quality Certificates �� • r s i BRAWN BY : IEC61215,IEC61730,UL1703CE � e 1(; -"--' i - ---- 1, aUPERTINO IS09001:2008:Standards forquality 4? I -;, R it Istvan D Szabo v is management systems a t ssf ! a + t� rfmEn� ISO/TS16949:2DD9:The automotrve q ualit management system „3;1: A . ( � g Y . . � r k ' , REVISION mans r�-��• �,.. �`, , ; �, '. dts `��` 3�•f�„ --wow.: ,...:rsf` �'yi cr� Bks to a so es x`u..c K ) l r.: E 0 S io�I4 ` SC 42 yr U f / t' ("� /�y��/r^� `t F / [�, t ,� � vaoarM vwcmr(tn 5 _ .-�.�. ._�.-: r.?.�Il. ul�l1� �LJiHIE"�l/"t7 #.dt.- �i.,_. A Environmental Certificates .N -� r • IS014001:2004:Standards forEnvironmental \c,, „4 „�} - ,.,�. • ,�,// ISSUE DATE `' management systems About Canadians®lar ., //�� ` g D�cJ24/2013 >c Canadian Solar Inc.is one of the world's largest solar Canadian Solar was founded In Canada in 200t and was • Hazardous HS stance Certification for companies. As a leading vertically-Integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) In 4 6 Hazardous Substances Regulations 9 manufacturer of ingots,wafars,cells,solarmodules and November 2006. Canadian Solar has already expanded its • Reach Compliance solar systems. Canadian Solar delivers solar power module manufacturing capacity to 2.05GW and cell products of uncompromising Quality to worldwide manufacturing capacity to1.3GW in 2011. customers. Canadian Solars world class team of C professionals works closely with our customers to SHEET NO. provide them withsolutions for alitheir solar needs. H. ,SrRiv�rbend tea-. www.canadiansolar.com 04 CLEAN SOLAR INC. STANDOFFS SPECIFICATION SHEETS 11145 KOLL CIRCLE SUITE 109 QBase Universal Tile Mount I QMUTM QBase Universal Tile Mount - Instructions for Rafter Installation San Jose CA.95112. (formerly called Universal Tile Mount) MVAIN9119�'PV products are NOT designed and should.NOT be used to ar-chor fall protection eq UilDrnem NO Cont. Lic # 910849 ITEM DESCRIPTION QTY. I GBASE.1-1/C ID,FOR 5116"HARDWARE,A360.1 CAST AL www.cleansolar.com 10 2 CAP SCREW,HEX HEAD,5116-18 X 3/4"UNC-2A, GRADE-8 9 8 3 POST,1.25'OD X 6.5.606345,MILL 4 LAG SCREW,HEX HEAD.5116'X 3',ZINC 2 SUBI-LA51-11N(3,SPUN CONL,QUAbt,Y Ay Y"UZU' I S AM3 A 7 RIM AL, I 6 FLASHING,SPUN CONE.,19'XIS'X.037', MILL QBase Universal Tile Mount I QMUTM 7 COLLAR,COUNTER FLASHING,1-114"ID EPDm 1 (formerly called Universal Tile Mount) WASHER,SEALING,5/16"1D X 1-1 hr OD,EPDM 8 BONDED SS CLEA NSOLAR 9 WASHER,=ENDER,5/16"1D X I-OD,18-85S I Additional Dimensions 6 10 WASHER,SPLIT-LOCK,5/16"ID,18-8 SS I j Remove tile at selected location of mount. Locate and mark center of rafter. Use a straight edge and measure up 6%"from bot- ---------- -- to.of tHesto center of the mount over the G-ter 8.0 Post 01.25 11 CAP SCREW.HEX HEAD,5/16"-18 X I",UNC-2A-18 8 SS of rafter. POST AND TOP FLASHING AVAILABLE IN MILL,CLEAR ANODIZED,AND DARK BRONZE ANODIZED FINISHES :4 11.5 04.0 < 18.0 3 LU 4 A e-- Q 0 �0- AVU4�U.it.7'.9".1,CJ IZ'finisnedheights. 0"Mountw U QMUTM:QBASE UNIVERSAL TILE 1.5-- Top Flashing Otem 61 MOUNT Align QBase over rafter center and drill two carefully dean the building paper then install pri- Take rare to do a quality installation.When using 29'0 < DRAWN as mw REV 'A."pilot holes.Place grade-8 machine bolt un- maty flashing in either a three-course method or the paper method,cut a piece of paper h8"wide 4.5 U der Mase in hex slot,threads pointing up.Lag properly lapped paper method'Apply bead of to slide under the course above and over the p'i- 'Nrica' WA �DAT-E.---71-19M--12-d 5 Fay.'rvxut. OBase into rafter on marks. sealant in the shape of an upside down U on the maryflashing of the mount. ------------!f Ear side of the sub-flashing. 0 LL 4 3 2 i > 9.0 1 75 0 U Yoj -now ready rot the rack of r QBase(item 1)and Post iflern 31 Lag Bolt Sped4cadons clic Follow all the dirEcticnz of LU 'ac'k -asAr(.'HaStrl��r- - X 3.5 - - F- a- r.anufactute UIe,-r13,-1UfaCtL1reL 0 F.Lrch -330 QMUTM: All roofing manufact i rs' wtil-te-i .8 Universal rile Mount DAvl.,Fit.Sued; .413 1175 235 )2 irsirUCtI0n5 MUt ZISO Oe f0Il^,'AieJ Enael-S--Lodgepo%Fine(M 1650 f h%0.11 A6 1175 235 sm-1-mmoim- -� ---- �-�an�one modifying a roof 5ys-n- QBase Primary Hwhing(Iterriti) IDA Hem,Fir A3 212 a� 2 A [ioxe uzii� Pl,-asc •consult the roof rrianufactu!c� H-,F¢(North) A6 I176 236 m-5- '=�=! specs and instru-Jorts V�prior io uci, S-them Pit,. .55 16th 307 in therociff. 5 4 3 2 si-I Pit-.Fa .42 1 Sm-Mw F'.(E nt 2rr T-ttiiA hid-qriid.it MSR and MEL) M 266 Cut a hole in the the removed,with roomto get the Pre-bend the flashing to follow the contour of the For more details on underlayment water- swrcev Amencao wood C-A,NDS2005,Tabte 11.2 A,11.3.2 A post through.Replace the in position.Insert post tile if curved.Apply sealant where post and flash- proofing please visti our websIte: Notes, and tighten into place.Install the I S'x 18"flashing ing meet,and install counter flashing collar.(Be 1)Thread must be embedded in a rafteror other structural toof member. and apply sealant around the opening. sure to seid off the post from weather exposure 11mytirsal-tile-mountht-I 2)S-19C for mq.md ed9i,dic%,,t- with the sealing washer(item 8),in the interim be- Importantto marntainwaterproofing of Substrate it 1;Important to make sum the aluminum pitmarytWhing is properly placed over the QBase and order the course of paper above.If the fore racks are Installed.). pape,abowdoestatreath,clue tolayout.place an adilnicrt*lpiece oftoof ng paperoverthe primaryflashing and underthe nm courseof paperabovet(SeemstrIctiois on reverse) Q,uickMount P%vfG' Quick Mount PV® 925-687-6686 a www.quickmountpv.com 9 info@quickmountpv-com C) RI 7.2.34 2700 Mitchell Dr.,Bldg 2 •Walnut Creek,CA 94598 Aug-2012,Rev 3 Ln Z U UJ 44 Ln �1111 0 RAILS SPECIFICATION SHEETS r1ii.. >1 Ln LU J -T- C) UJ PRODUCT DAT SHE C:) A E-i irenRidge XR Platform IronRidge XR Platform U U 00 PRODUCT DATA SHEET SPECIFICATIONS MAX SPAN CHARTS U) CJ #XRL/XRS Rail: CO 6105-TS extruded aluminum(anodized) Snow Load(psi) 1.. KEY FEATURES *XRL/XRS Splice Bars: Wind Speed(mph) 0 D5f 10 psf 20 psf 30 psf 40 psf CL. •Extruded aluminum 6105-T5 extruded 91.1 mph 13W 13'-6" 12-U" 11=U" 9-6" aluminum 100 mph 13'-0" 13'-0" 12-0" 111-01 9-6" components are rightweight *Standoffs: 110 mph 12'6" 12'm6" 12'-0" 111-0" 9t-6' U J for easy handling yet strong 6105-TS extruded 120 mph 11-6" 11-6' 11-6" I1=01 9-6" enough for most roof mount aluminum 130 mph 10'-6" 10!-6" 10'-6' 9t-6' applications *Adjustable L-feet: 140 mph 96" 91-61 9-6" 91-6" 9-6" •Choice of XRL{lightweight) 6105-T5 extruded 150 mph 91-0" 91-01 91-0" 91-0" 9!:-01 and XRS(standard)rails (D •Both XRL and)RS rails come aluminum*Panel Clamps: with slots for attaching L-feet 5052-H32 aluminum and top slots for attaching +Hardware: Snow Load(psf) panel damps 18-8 Stainless Steel Wind Speed(mph) a psf 10 psf 20 psf 30 psf 40 psf •XRS rails has slot for bottom 90 mph 8-011 8'-0" T-On 6'-6" 5-6., mounting damps IGO mph 7'-0" 7'-0' 71-0. 6-6' 5'-6' 4,Hidden internal splice bars are XRS PROPERTIES 110 mph 7-0" 7'-0" 7-0- 6-6" 51-6" aesthetically pleasing +Area=.807136 incheSA2 120 mph 6-6" 6-6' 66" 6-6" 5-6" •Internal splices provide *Centroid relative to output 130 mph 6-0" 6'0' 6'-U" 61-01, 5t-6" superior strength and -V -6' _6" -6" .6" flexibility with L4eet coordinate system or 140 mph 51 S' 51 5' 5� *X=0.5556 150 mph 51-0" 5=0" 51-0. 51-0" 51-0" placement *Y=1.4097 •Adjustable L4eet have vertical *Z=120.000 LOAD CONDITION ASSUMPTIONS extension slots for easy ♦Moments of Inertia of the * FlIush roof mounting installations only adjustability of up to 1-3/8" area(at the centroid) * Roof zone I installations only •Standoffs provide increased The InorRidge XR platform is a reliable,comprehensive,and feature rich photovoltaic *Lxx=0.8430 + Roof slope must be less than 45 degrees airflow and ventilation and mounting solution.Anchored by the XRS(Standard)and XRL(Light)rails,the XR *Lxy=0.1117 * Module dimensions are 63"x 32"or less enable precise placement of platform includes all of the components necessary for supporting virtually any *Lxz=0.0000 + Exposure Category C only SCALE flashings commercial or residential roof mount installation,regardless of surface material or *Lyx=0.1117 * Building height must be less than or equal to 30 feet •Standoffs come in four roof grade- *Lyy=0.1822 * Clearance between roof and rail is at least 2 inches standard heights:T,4",6, *Lyz=0.0000 + End cantillever span not to exceed 403'0 of the adjacent Interior span and 7" The XRS and)ML rails are manufactured from extruded aluminum to maximize spans *L2x=0,0000 * No rag splice permitted within the middle 1A of the span •XR platform compatible with while minimizing weight for improved handling.The graceful curves of the XRS rail *1-2y=0.0000 popular flashings including will please even the most aesthetically demanding customers.Rails can be extended *Lzz=1.0252 For installations that do not conform to the load condition assumptions above, DRAWN BY : OuickMount and Oatey with the IronRidge patent-pending internal splice bars,providing a strong support Polar Moment of Inertia please refer to wwwAronridgecom for a more complete engineering anallysis. (7JUPERTINO •Panel damps for both top and bottom mounting variety of options in attaching IronRidge rails to the roof,including adjustable L-feet, ♦Principal Moments of Dep-9ftent connection and ultimate flexibility in footing attachment locations.Installers have a ♦At Centroid=1.0252�4 Istvan D Szabo •Panel damps for most popular aluminum standoffs,and tilt legs for optimizing power.In addition,IronR!dge Inertia L-FOOT DIMENSIONS ph otovottaic modules accommodates modules from most major manufacturers-Topi-dawn panel damps *Ix=0.1638 •mid-clamp design maximizes securely grip the outside frame of the module,freeing the installer from the *Iy=0.8614 tt REVISION panel density constraints of panel mounting holes.The XRS rail has an additional-side slot to enable +Angle between Principal •Ground clips eliminate the the option of bottom mounting.Lastly,grounding clips pierce the anodized rails, and Part Axes need for copper wire between creating aground path through the equipment and eliminating the need to run ♦Angle=99.343 degrees T3 "'ODE C 01VIPLIANGE modules copper wire between every module. *Moments of Inertia •The XR Roof Mount *LXX=11625.205 ISSUE DATE: components are covered with Irciriffidge provides a complete technical support system that includes step-by-step *LXY=0.5204 an industr~ng 10 year Installation guides,engineering certification documentation,eaWo-read span charts, *L)CZ=53.8153 Dec/24/2013 limited product warranty and and on-line configurabor software. *LYX=0.5204 a 3 year limited finish *LYY=11623.1939 warranty See reverse for additional product specifications.Please contact your local distributor *LYZ=136.5369 •All XR Roof Mount for configuration assistance. *LZX=53.8153 SHEET components are PE certified ♦*LZY=136.5369 *LZZ=2.8784 707-459-9523 707-459-9523 AO-AL I RD N R I DG E sales@lronridge.com ZjAkIRONRIDGE salesiPirionridge-corn www.i=ddge.com wmironfidge.com 05