Loading...
14010113 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22025 CREEKSIDE CT CONTRACTOR:SOLARCITY PERMIT NO: 14010113 OWNER'S NAME: ABHAY BHORKAN&MANSI MODAK 3055 CLEARVIEW WAY DATE ISSUED:01/21/2014 OWNER'S PHONE: 4082422169 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 I!X LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL E] _ INSTALL 18 ROOFTOP,FLUSH MOUNTED PV PANELS License Classy_ C C, Lic.4 q �6 L4 (4.5KW) Contractor Date 01 (/1 /1 1 1 1 hereby affirm that I am licensed unde the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$18000 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32639039.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS O T ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save O DAY L LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgmen , costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Ssued by: Date: Z / with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signatur Date 2-t l All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Section 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this 1 Zt L( Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records, granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION O COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO, CA 95014-3255 ` O (408) 777-3228• FAX(408)777-3333•building(dcupertino.org \ J� CUPERTINO � �\\ PROJECT ADDRESS ///20 -Z APN M 3 JJ OWNER NAME �n t,.4-,/� PHONE 0 2-�2_2)6qE-MAIL STREET ADDRESS\ n 2 l C YL I�Y�� C� CITY, STATE,ZIP J 1 `� � FAX L L 11f-� �Soi4 CONTACT NAME PHONE„ E-MAIL, STREET ADDRESS CITY.STg:[E. ZIP �L FAX ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME l_� LICENSE NUMBER� G i vLr LICENSE TYPE jO BUS.LIC R O COMPANY NAME &MAIL l FAX G,c�.+�( �G•i�JL�SL. STREET ADDRESS LtT CITY,STATE�IP�-� C4�U� PHONES ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS LIC M COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF 2"'S—FD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA El Yes ❑ NO FLOOD ZONE ❑ Yes ❑ No ST �SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SO/JIRPANE/_S: NUMBER OF PANELS/UNITS: gKILOWATTS: �- TOTAL VALUATION DESCRIPTION OF WORK ,7-izd RECEIVED By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I h e_r ea and the information I have provided is correct. 1 have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to bu' ing construction. 1 authorize representatives of Cupertino to enter the above dentifed property for inspection purposes. Signature of Applicant/Agent: Date: T 7)_ SUP EMENTAL INFORMATION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER a - ❑ EXPRESS U U y ❑ STANDARD U ❑ LARGE c ❑ MAJOR PYApp_2012.doc revised 06/20112 CITY OF CUPERTINO FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 22025 CREEKSIDE CT DATE: 01/21/2014 REVIEWED BY: MELISSA APN: 326 39 039 BP#: `VALUATION: 1$18,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK INSTALL 18 ROOFTOP FLUSH MOUNTED PV PANELS 4.5kW SCOPE .._.. Phrtnh. PlcF;r C uvA Yc_ Plan Chuck He& Peraw Fee: i'lumb. Permit Fee: Flee. Permit Fee, Other Mech.Insp. Other Plumb Imp. Other Elce.Insp. Tech. Insp.Fee: Plumb. Insp. Fee: '_r.Insp.Fee: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 El' 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: E) Reg. Q OTT0.0 hrs $0.00 $229.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee-(F) Reg. C) OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Conswitetion Tczv: A(Pninistrtrtive Fee: Q Work Without Permit? 0 Yes (j) No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel l�cxr7trnentutian Fees: Building or Structure 0 i Strom);Motion Fee: 1BSEISMICR $1.80 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $2.80 $229.00 TOTAL FEE: $231.80 Revised: 01/15/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, PLO'F PLAINS BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CHECKED BY CONIC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE DATE 01124 1" l4 EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING PLANNIN DEPT. GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. DATE GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) BLDG. DEPT.. I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC Cup` kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). COMMUNITY DEVELOPMENT DEPARTMENT kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN BUILDING DMSION -CUPERTINO Building F)e a,, ,, LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY APPROVED Figs MIN MINIMUM UL LISTING. -- -Avv L (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE This set of plans and specifications MUST be kept at the NEUT NEUTRAL UL—LISTED LOCATION PROVIDED BY THE job site during construction. It is unlawful to make any REVIEWED FOR C;0DE CO3% 1 A,-i!-,L NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING changes or alterations on same, or to deviate � OC ON CENTER HARDWARE. therefrom, without approval from the Building Official. :2vie��ed By PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND The Stamping of this pl cations SHALL NOT PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. be held to r to n a proval of the ►iol�iVn SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR of ovisi TOrdinance or Stave La-,.r. SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(8) & BY STC STANDARD TESTING CONDITIONS 690.47. nFFIC-E COPY TYP TYPICAL pA t ZI 1 UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Vac VOLTAGE AT OPEN CIRCUIT W WAIT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES cut heets AttalNed IAGRAM CA # 888104 1. THIS SYSTEM IS GRID—INTERTIED VIA A X C-10 UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ! 3. SOLAR MOUNTING FRAMES ARE TO BE �� GROUNDED. 4. ALL WORK TO BE DONE TO THE 2013 MODULE GROUNDING METHOD: SLEEKMOUNT CALIFORNIA BUILDING CODE. 5. ALL ELECTRICAL WORK SHALL COMPLY WITH REV BY DATE COMMENTS AHJ: Cupertino THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY iii7izo�a COMMENTS THE 2013 CALIFORNIA ELECTRIC CODE. REvn NAME UTILITY: Pacific Gas and Electric Company (PG&E) e CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB-9502555 00 PREMISE OWNER DESCRIPRG`N: DES^M: CONTAINED SHALL NOT USED FOR THE BHORKAR, ABHAY U BHORKAR RESIDENCE Scott Loweryn �'N!'•SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:NOR ; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 22025 CREEKSIDE CT 4.5 KW PV Array /J �'.,., • PART TO OTHERS OUTSIDE THE RECIPIENT'S MoouLEs C U P E R TI N 0 C A 9 5014 ORGANIZATION, EXCEPT IN CONNECTION WITH r THE SALE AND USE OF THE RESPECTIVE (18) Advantage Module3055 Clearview way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Son Mateo, CA 94402 PERMISSION OF SOLARgTY INC. INVERTER- 4082422169 PV 1 1/17/2014 (888)—SOL)CITY(765-2489)�www.eolarcly.00m SOLAREDGE SE5000A—US—ZB—U COVER SHEET PITCH: 18 ARRAY PITCH:18 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL:Comp Shingle STORY: 2 Stories CUPER a!;1140 3'Fre Setbxk — — — - ' Building Department - � 1 �E Vi EO/r[1 FOR CGDE (-I'0,'\j':P L I A ! F Reviewed By A LEGEND Front Of House O (E) UTILITY METER & WARNING LABEL LL m� INVERTER W/ INTEGRATED DC DISCO h & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC 1 AC DISCONNECT & WARNING LABELS ULEER N v O DC JUNCTION/COMBINER BOX & LABELS U (E)DRIVEWAY N DISTRIBUTION PANEL & LABELS 0 N N LOAD CENTER & WARNING LABELS 3'Fre O DEDICATED PV SYSTEM METER Inv O R CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE ,, 11 INTERIOR EQUIPMENT L_'J TOTAL ARRAY AREA (SF): 324 SITE PLAN TOTAL ROOF AREA (SF): 2885 Scale: 3/32" = V C Z TOTAL ARRAY AREA IS ICI 11.22 01' 10' 21' PERCENT OF TOTAL ROOF AREA CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9 5 0 2 5 5 5 00 PREMISE OWER. DESCRIPTION: DESIGN. CONTAINED SHALL NOT BE USED FOR THE BHORKAR, ABHAY U BHORKAR RESIDENCE Scott Low ry -''`!r SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: -,�; NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 22025 CREEKSIDE "T 4.5 KW PV Array �� �A. PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: - CUPERTINO, CA 95014 055 CI 3eome■Way � � THE SALE AND USE OF THE RESPECTIVE (18) Advantage Module PAGE NAYS SHEEL REV DATE San Mateo,CA 9M02 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T:(650)638-1026 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE5000A-US-ZB-U 4082422169 SITE PLAN PV 2 1/17/2014 (666)-SCI-CITY(765-2+69)www-Warcity.com S1 (E) 2x4 " —4 4'-8" (E) LBW 8 9 01' (E) LBW SIDE VIEW O F M P 1 RAFTER: (E) 2x6 @ 24" O.C. A NTS CEILING JOIST: (E) 2x6 @ 24" O.C. MAX SPAN: 9'-0" MAX LANDSCAPE STANDOFF X—SPACING: 72" O.C. CUPERTINO wilding Department J i s 2 1 2314 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER .E`v!tWEfJ FOR CODLGU\/PL_i�iJCE & FENDER WASHERS Re4letiveu 8y LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE (4} PLACE MOUNT. (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) T(5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER STANDOFF J B-9 5 0 2 5 5 5 0 0 PREMISE OWNER DESCRIPTION: DESIGN: CONTAINED L - INE INFORMATION HEREIN q6 NUMBER BHORKAR, ABHAY U BHORKAR RESIDENCE y CONTAINED SHALL NOT BE USED FOR THE Scott Low f SolarCity. NO BENEFIT OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM; ou 22025 CREEKS-IDE GT AA., . NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 4.5 KW !'V Army ,,n PART TO OTHERS OUTSIDE THE RECIPIENTS - ( ! / . ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P E R T!N 0, CA 95614 // THE SALE AND USE OF THE RESPECTIVE (18) Advantage Module 3055 aervl°"Way S"CITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DAIS San Mateo,CA 94402 1029 PERMISSION OF SOLARCITY INC. INVERTER-O4082422169 PV 3 1/17/2014 (888j�SOOLL-CITTYY 638-1028 F.(650) SOLAREDGE SE5000A—US—ZB—U STRUCTURAL VIEWS UPLIFT CALCULATIONS 01.17.2014 -�;�� la('City S1eekMountTm PV System "°'�°"X17'' . Structural Design Application RIc C_ u Rpaf - Comp Roof Rt>bF is' 2'rdC PV Mbduk Orientation - - Umdscape PV'Module Wdtfi - StendoFf Ha[fuwariecam Morult T C Ground S ww.Lmd pg OA p ASCE Table 7-1 OR WRAof Snow OIrwPVModules 0.0 Psf Eq:7A-1 Building Department I� r' VOW Design Code ASCE 7-10 IL ,,;, ,d 2 ! 204 Ba9ci irdSpeed V110mpt1 i+=! 5- UDE C;OMPLIANC Roof Style Gable Roof s0.a , - AW ft a Effective Wird Area 1 Module A 17.6 st IBC 1509.7.1 .�IOit CoeNi�r>if0t W(nd R+ 6tposure Kz 0.70 Table 30.3-1 Q 26.8 Wind Dlrerbonality Factor Kd OAS Section 26.6-1 Velocity Pree.su a qh Gh a:.002Sri ( (lEd) "'2: Equation 303-1 8A Pat Ext..P mswm Coefficient(Up) F+0 X+2AjWC sN8 URI Wurd Po re — uatiorr 3OA-1 wkW Prenum Down down 16.0 Max AWAmble SUWoff Spacing Landwape 72• 4. '6'. Config P Load W-PV 3 psf 7ww - '" *r of 9lardoff T-allow 50p I S CONFIDENTIAL- THE WFORYATION HEREIN ► JB-9502555 0 0 POM p DEMNIN: Oma CONTAINED SHALL NOT BE USED FOR THE BHORKAR, ABHAY U BH.ORKAR RESIDENCE SCR Lowiry -- BMW OF ANYONE EXCEPT 9MAMM INC., YOUNiIN6 SISTER NOR SHALL IT K DISCLOSED IN WHOLE OR IN CoMp Mount Type C 22.025 CREEKSIDE CT 4.5 KW PV Array • PART TO OTHERS OUTSDE THE RECIPIENT'S troouF� GU.PERTINO, CA 95014 _.. _ _ ORCAmz1�N ET(OEP.T-1N CONNECT w.mi ._, ay THE SALE AND USE OF THE FEWEC71 (T8)--Advantage Module cn bmClemCA M14 SMARCITY EQUIPMENT, TWTHOUT THE WRITTEN XWEI EIt PAGE SHEEL DAA T:(650)838-10028 F(650 X1029 PERM"OF SMARCITY W' SOLAREDGE SE5000A—US—ZB—U 4082422169 UPLIFT CALCULATIONS PV 4 1/17/2014 (686)-SOL-CITY(765-2489)...AoWdty.corn GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:Square D Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE #S�E5000A—US—ZB—U LABEL: A —(18)Advantage Module CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1006137706 Inverter; 5000W, 24OV, 97.57.; w/Unifed Disconnect and ZB, AFCI PV Module; 250W, 227.9W PTC, Poly, 60cell, Blck Frame, White Bcksht, ZEP C-10 INV 2 Voc: 38,4 Vpmax: 30.1 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL E 200/2P MAIN CIRCUIT BREAKER Inverter 1 20OA/2P 3 SOLAREDGE SE5000A—US—ZB—U (E) LOADS L1 zaov SolarCity • • L2 GFP/GFCI N 2 A 1 30A/2P ---------------------------------- -EGG __ DC+ DC - - - - A �-----------—- GEC �t Q DG DG -----1 String(5)Of 18 On MP 1- B I I I N I I EGGGEC Z Z c� GEC TO 120/240V SINGLE PHASE UTILITY SERVICE I CUPERTINO E Building Department L_ RE`,,'lE',JVEs-, FOR CODE C,OlViPUANCE By f1AT Voc* = MAX VOC AT MIN TEMP Q yy## AC , ` (1)S2ax°21"14G4SSUNFUSED,JUNCTION DC I (1)SQUARE D H 230 PV BACKFEED BREAKER Breaker, �A�, 2 Spaces —(1)ZEP /850-1196-001 Combiner Box Bracket; For ZEP, bottom mount only P V (18)SOLAREDGE 3OD-2NA4AZS PowerBox Optimizer, 30OW, H4, DC to DC, ZEP 1 AWG (+10, THwN-2, Black (1)AWG 110, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O (1)AWG #10, THYM-2, Red O (1)AWG #10, THYM-2, Red Vmp =350 VDC Imp=12.69 ADC O (1)AWG f10, Solid Bare Copper EGC Vmp =350 VDC Imp=12.69 ADC (1)AWG (+10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20.83AAC (1)AWG /10, TH"72,.Green EGC, . . _-(1)Conduit Kit;.3/4'.EMT . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ _ _-(1)AYWG /8,.THWN-2,.Green. . . ECC/GEC.-(00onduit.Kit;.3/47.EMT. . . , . . . . . . PREMISE OWNER: DESCRIPTION DESIGN: CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B-9502555 00 N-4Nk CONTAINED SHALL NOT BE USED FOR THE BHORKAR, ABHAY I.) BHORKAR RESIDENCE Scott Low ry �'.;;SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MDUNTING SYSTEM: �•.,,. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 22025 CREEKSIDE C I 4.5 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CU P E R TI N 0, CA 95614 THE SALE AND USE OF THE RESPECTIVE (18) Advantage Module 3055 CleQ"1Gw Way SOLARCIY EQUIPMENT, WITHOUT THE WRITTENPAGE NAME SHEET: REV: DATE San Mateo, CA 94402 PERMISSION OF SOLARCIY INC. INVERTM, T:(650)638-1028 F:(650)638-1029 SOLAREDGE SE5000A—US—ZB—u 4082422169 THREE LINE DIAGRAM PV 5 1/17/2014 (888)—SOL—CITY(765-2489)www.Warcity.com ELECTRICAL CALCULATIONS Hardware Qty Model Voltage Drop Calculations Module: 18 Advantage Module 250 Vdrop= (Imp) (2*Length) (Resistance) /(Vmp) DC Converter: 18 SolarEdge OP250-LV Inv Power DC W PTC DC W STC Inverter Imp(A) Max.Length(ft) Wire Inverter A: 1 SolarEdge 5000 5000 4020.16 4500 Input: 8.31 45 AWG_S0 Inverter B: Vdrop= (8.31 -90 1 -0.00124 Ohms) 493.038 0.29 5000 4020.16 1 4500 Inverter A Imp(A) Max.Length(ft) Wire Output:j 12.69 1 50AWG_10 Vdrop= ( 12.69 1 100 1 *0.00124 1 Ohms) 493.038 0.32 Inverter A Stringing Inverter B Stringing Comb. Drop Imp(A) Max. Length(ft) Wire String 1: 18 Modules String 1: Modules 12.69 10 AWG_10 String 2: Modules String 2: F-]Modules Vdrop=k( 12.69 *20 1 *0.0012 1 Ohms) 0.1269 0 Photovoltaic Module Electrical Specifications: Photovoltaic Source Circuit(Modules to PowerBox) Voltage Drop Calculations °F °C Advantage Module 250 Voc at Min Temp= 42.71 V Record Low Temp: 17 -8 Power(STC)= 250 W VOC= 38.4 V Max Average High Temp: 82 28 Power(PTC)= 227.9 W Vmp= 38.4 V Voc= 38.4 V Vmp at Max Temp= 27.39 V Vmp= 30.1 V Isc= 8.87 A i, CUPERTINO Isc= 8.87 A Imp=j 8.31 A Bulldinq Der artfTTm Imp= 8.31 A (cont-- 11.09 A Tvoc= -0.13056 V/deg C 11' 1 2014 Tvmp= -0.13545 V/deg C AWG 12 Table 310.15(B)(16) --- Tisc= 5.7655 mA/deg C Ampacity= 30 > 13.86 A Corrected Ampacity= 17.40 A > 11.09 A CODE CUNPt_IAN�E Temperature Derate= 0.58 , Conduit Fill Derate= 1 DC Converter Electrical Specifications: Inverter A Input Circuit(PowerBox to Inverter) Unused SolarEdge OP250-LV String 1 Power= 250 W Vmax= 500 V Wire Length 45 Vmax= 96.77 V Wire Length 50 Efficiency Factor- 0.987 Vmp= 350 V Vmp= V Vmin_input= 5 V Imax= 15 A Imax= A Vmax_input= 60 V Imp= 6.77 A Imp= A Imax_input= 10 A Vmax-output= 500 V AWG 10 90°C:Table 310.15(6)(16) 90 C:Table 310.16 Imax-output= 15 A Ampacity= 40 > 15 A Ampacity= > A Corrected Ampacity= 23.20 A > 15 A Corrected Ampacity= A > A Temperature Derate= 0.58 Temperature Derate= Conduit Fill Derate= 1 Conduit Fill Derate= OCP= 20 A OCP=j A DC Converter Electrical Specifications: Inverter A Output Circuit Combined Inverter Output Circuit SolarEdge 5000 Service Voltage= 240 V Service Voltage= PIA V Power- 5000 W Icont= 15 A Wire Length 10 (cont= Wire Leng h Vmp_input= 350 V Vmax-input= 500 V AWG-10 90°C:Table 310.15(B)(16) 90 C:Table 310.16 Imax_input= 16.664 A Ampacity= 40 > 18.75 A Ampacity= > A Vmax-output= 240 V =Service Voltage Corrected Ampacity= 36.4 A > 15 A Corrected Ampacity= A > A Imax-output= 20.83 A =lcont Temperature Derate= 0.91 Temperature Derate= Conduit Fill Derate= 1 Conduit Fill Derate= OCP= 30 A OCP=l A CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER: DESCRIPTION: DESIGN: JB-9502555 00 CONTAINED SHALL NOT BE USED FOR THE BHORKAR, ABHAY U BHORKAR RESIDENCE Scott Low ry �,`'� '} BENEFIT OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM: 22025 CREEKSIDE CT 4.5 KW PV Array � �i;,Solar i y. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P E R TI N 0, CA 95014 m THE SALE AND USE OF THE RESPECTIVE (18) Advantage Module 3055 Ciearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV' DATESon T:(650)636 1teo, CA 94402 F:(650)638 1029 PERMISSION of saaaaTY INC. SOLAREDGE SE5000A-US-ZB-U 4082422169 ELECTRICAL CALCULATIONS PV 6 1/17/2014 (868)-SOL-CITY(765-2489)www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 22025 Creekside Ct INVERTER AND DC DISCONNECT UTILITY O SERVICE OUPILERTINO •;, Building Departrrtenl( SOLAR PHOTOVOLTAIC " "' .i 2 1 2"'14 ON ROOF REVIEWED F O Fi CODE E;o v.P i iANCE PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 Hevievted % - OPERATING VOLTAGE = 240V MAX CURRENT = 20.83 A CONFIDENTIAL — THE INFORMATION HEREIN JOB HUMBER: JB-9502555 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BEUSED FOR THE BHORKAR, ABHAY ll BHORKAR RESIDENCE Scott Low ry So�a�City. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: /�T �'.,a NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 22025 CREEKSIDE I 4.5 KW PV Array �7 A. . PART TO OTHERS CUISINE THE RECIPIENTS MODULES CUPERTINO, CA 95014 ��/ Sir 3055 Clearvlew way ORGANIZATION, EXCEPT IN CONNECTION WITH � THE SALE AND USE OF THE RESPECTIVE 18) Advantage Module PAGE NAME SHEET: REV: DALE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE5000A-US—ZB—U 4082422169 SITE PLAN PLACARD PV 7 1/17/2014 (m8)-SOL-CITY(765--2489)www.solarcity.00m WARNING:PHOTOVOLTAIC POWER SOURCE , PV SYSTEM WARNING •' DISCONNECT FOR UTILITY OPERATION ELECTRIC SHOCK HAZARD •• •- • - • TPHO ITDUCTORS OF A S C SYSTEM ARE OVO DEDAND PHOTOVOLTAIC DC UNGBE NERGIZE DISCONNECT •�- MAY 8E ENERGIZED .• � � .•� WARNING „- ELECTRIC SHOCK HAZARD •• ''- '•' • DO NOT TOUCH TERMINALS MAXIMUM POWER- TERMINALS ON BOTH LINE AND POINT CURRENT(Imp)_A •.- LOAD SIDES MAY BE ENERGIZED MAXIMUM POWER-MV •• IN THE OPEN POSITION POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Isc) A .•- • • WARNING INVERTER OUTPUT CONNECTION •- • • DO NOT RELOCATE WARNING THIS OENT D " ��� DEVICEVICE ELECTRICAL SHOCK HAZARD • DO NOT TOUCH TERMINALS ' TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION .•- • • DC VOLTAGE IS PHOTOVOLTAIC POINT OF '• ALWAYS PRESENT WHEN INTERCONNECTION _ • _ SOLAR MODULES ARE WARNING:ELECTRIC SHOCK •• •• EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE . •- • • DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. • • -• WARNING _ ,,_ PV POWER SOURCE MAXIMUM AC A ELECTRIC SHOCK HAZARD ••0 OPERATING CURRENT _ IF AGROUND FAULT IS INDICATED NORMALLY GROUNDED MAXIMUM AC = V CONDUCTORS MAY BE OPERATING VOLTAGE UNGROUNDED AND ENERGIZED CAUTION PHOTOVOLTAIC AC I I PHOTOVOLTAIC SYSTEM • DISCONNECT "" CIRCUIT IS BACKFED • ' •' ' ' MAXIMUM AC A • CAUTION • •-• OPERATING CURRENT ••- DUAL POWER SOURCE ••" MAXIMUM ACV • SECOND SOURCE IS 0 OPERATING VOLTAGE _ PHOTOVOLTAIC SYSTEM • �' ' ' ' SolarCity SleekMountTM - Comp SolarCity SleekMounff - Comp The SolarCity SleekMount hardware solution • Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTIA modules aesthetics while minimizing roof disruption and .Interlok and grounding devices in system UL • Drill Pilot Hole of Proper Diameter for c labor.The elimination of visible rail ends and listed c UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 ! Seal pilot hole with roofing sealant to a more visually appealing system. SleekMount as"Grounding and Bonding System" ® Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with .Ground Zep UL and ETL listed to UL 467 as \ layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the Place Comp Mount centered need for rail and reducing the number of • Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance 0 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw ,.. , •p .;.: Place module ! Components 0 ® 5/16"Machine Screw ® Leveling Foot ® Lag Screw ® Comp Mount C 0 Comp Mount Flashing _ UPEIRTINO uiiciinq DAI'artmPrn 2 1 2014 ® ;rti�IEtj\.,E1 Or. G> E i;OMPI/I,ANC . 7 ,K,�-�v;ewed 8y Mia SolarCity, %W �� LISTED SolarCity January 2013 V� January 2013 SolarCity Advantage Module Electrical Parameters at Standard Test Conditions(STC) The SolarCity Advantage module represents a 60 Cell, ZEP enabled Power Output Pmax W 245 250 module.The values shown are the most extreme potential values Power Output Tolerances APmax W -0/+5 -0/+5 from SolarCity's portfolio of CEC approved and UL or ETL listed Module Efficiency nm % 15.23 15.54 modules. Modules will have a minimum 10 year warranty.The Maximum Power Voltage Vmp V 30.2 30.1 module installed will be one of the following: Maximum Power Current Impp A 8.17 8.31 Open-circuit voltage Ivoc V 37.8 38.4 Yingli Solar: YL2XXP-29b Short-circuit current lisc A 1 8.63 8.87 Trina Solar: PA05.18 ReneSola:JC2XXM-24Bb values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance 1000W/m2,Cell Temperature 25°C). BenQ: PM245P01 2XXW Canadian Solar: CSPX-2XXPX Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 178 185 Voltage at Pmax Vmpp V 27.8 27 Current at Pmax Impp A 6.54 6.7 Open-circuit voltage Voc V 34.5 35.4 Short-circuit current Isc A 1 7.08 1 7.25 NOCT:Irradiance at 800W/m2,Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/- 2 Temperature coefficient of Pmax y %/°C -0.45 Temperature coefficient of Voc QVoc %/°C -0.34 Temperature coefficient of Isc alsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/anodized black STs ® Weight 45.2 lbs (20.5 k ) `` epartrrment 2 1 2094 E�IGu� r,_ Fr7� C;O F COivl�'LIf1NC.B �:avievted BY YL250P-29b YGE - Z 60 YL245P-296 YGE - Z 60CELL SERIES CELL SERIES YL240P-29b YIN*-,0 LAR Powered by YINGLI YL235P-29b ELECTRICAL PERFORMANCE YL230P-29b U.S.Soccer Powered by Yingli Solar GENERAL CHARACTERISTICS Module type YL250P-296 YL245P-296 YL24NP-29b YL235P-2% YL230P-29b Dimensions(UW/H) 64.96 in(1650 mm)/36.98 in(M mm)/ _. ---.--.- 1St in(46mm) Power output P... W 250 245 240 235 230 Power output tolerances Ap- w -0/15 _- .-.__._-_ weight 45.28x:(20.5 kg) • Ideal for residential Module efficiency q. % 15.3 15.0 14.7 14.4 14.1 - --- and commercial applications where cost savings, Voltage atP.,a -V__ V 30.4 30.2 29.5 29.5- 29.5 Current at P. I. A 8.24 8.11 8.14 7.97 7.80 PACKAGING SPECIFICATIONS installation time, and aesthetics matter most. Opersdrcuk voltage Y. V 38A 37.8 37S 37.0 37.0 Number of modules per pallet 22 Short.circuit current Lc. A 8.79 1 -8. 63 8.65 8.54 8.40 ----- - Number of pallets per 53'container 36 STC:100r Nim'irradiance,25-C cell temperature.AMI.Sg spectrum acmrdirg to EN 60904-3 Best Choice-for-NSTALLERS Avenge relauve efficiency reduction of 5.O%at 200W/m'accord,ng w EN 6090a1 Packaging box dimensions(UW/H) 67 in(1700 mm)/45 in(I 150 mm)1 47 in(1190 mm) Lower balance-of-system costs with Zep Operating Box weight 1076 ma(488 its) Compatible"frame. Power output p... W 181.1 ! 177.4 1 174.3 170.7 167.0 -- 0 Reduce on-roof labor costs by more than 25%. voltage at P. V.w V 27.6 27.2 26.6 26.6 26b Units:Inch(mm) Current at P. M A t 6.56 6.54 6.56 ) 6.42 6.29 Leverage the built-in grounding system- -t--.- - 38.9e 990 fit's mounted,it's grounded. open-circukvoltage v« V 35.4 Sas 3e.z ) 33.8 33.8 --.r- .. 36.85 9361 1.81(46) Short-circuit currem k A 7.12 6.99_ 7.01 6.92 i 6.81 8 Lower your parts count-eliminate rails,screws, mounting clips,and grounding hardware. NOCT:open-dmuamodule opeauontempeawreat800W1,1iadanre,20•Cambient temperature,1m/s wndspeed m Design and permit projects easily with access THERMAL CHARACTERISTICS to layout calculator and stamped drawings. Nominalopeaengcellt.mpaaere raocr a 46+/-2 S Temperature-0111cfent of Pm Y %rte -CAS • • areIT,I T paratun coefficient of Vee Bv.'19V°C - -033 1 Lower installation costs with savings across Temperature coefficient of 1. a. %/•c 0.06 Grounding hdae 9® a �6-00.236(6) equipment and labor. , Temperature coeffld.ntofV-p 11- %rc -0.45 V Minimize roof penetrations while maintaining the system's structural integrity. ® OPERATING CONDITIONS V Invest in an attractive solar arra that includes Mvoltage 600va Mounting holes y ax.system 4-0.256x0-315(6.5x8) a black frame,low mounting profile,and a Max.series fuse rating 15A aesthetic array skirt. Limiting reverse current 15A Drainage holes Y Increase energy output with flexible module 8-0.12x0.315(3x8) Operatlng gmpermure range -00 to 794•F(�So 90•C) layouts(portrait or landscape). COMPATIBLEZE FRAME Max.static load,from(*.g.,snow and wind) SO psf(2400 Pa) 3.9411001 Trust in the reliability and theft-resistance of WARRANTIES Max.static bad,back(e.g.,wind) 50 psf(2400 Pa) ` the Zep Compatible`"system. Leading limited power warranty*ensures Hailstone impact 1 in(25 mm)at 51 mph(23 m/s) 91.2%of rated power for 10 years,and 80.7% - - of rated power for 25 years. \� t CONSTRUCTION MATERIALS Ir AC SOLUTION OPTION _ V a/thickness) Low-iron /tempered/3.2 mm SECTION C-C The YGE-Z Series is now available as Front cover(materiatYP g ass 10-year limfted product warranty. Glass may have anti-renearve coating t � an Enphase Energized'"AC Solution. C.II(9wntiry/ma4riaVtypetdimansions/ - 60/polyaf&onf mukicrystall'ure/ This solution delivers optimum --- --- -a/#of b.aban) 156mmx156mm/243.3aea/2o0 A, u��lr,-(`�p� ENERGIZED In compliance with our warranty terms and conditions. Enca wlant(materie0 a vin �� 1 IV'FVI K 1 'y performance and integrated intelligence. p Ethylene yl acetate(EVA) �__ The Enphase M215-Z Zep Compatible Microinverter I-*(materiaVco" Arrodiz.dalumir-alloy/black _ RL)ildinq DePartTT el", blaming:Read ,/�,['S'talla4`art'as�d User Manual in its entirety is designed to connect directly into the Z Series module QUALIFICATIONS Junction box(protection degree) xIP65 before handlin .inktallina�`d{d b�orating Y ngli modules. .n ...l,'s,.. groove, the need for tools or fasteners- cable( nen h/aae/outside diameter) PVwre/43.31in(1100mm)/12AWG/0244in(6.2mm) 4"`.-- 6 14 9 9 tYP• st g g s •.' o '1 all with one easy step. UL 1703 and ULC 1703,CEC,FSEC,ISO 9001:2008, Plug connector Amphenol/H4/IP68 Our Partners , ISO 14001:2004,BS OHSAS 18001:2007,SA8000 (manufacturedtype/pmtection degree) • COQ GOMPL� ANCF The specifications in this datasheet are not guaranteed and are subject to change without prior notice. C This datasheet complies with EN 50380:2003 requirements.Intelligent real-time ssotowtst �US cc, � ® K�VI21aV E'(.� �� -- rnmroring at the system 411111111 and module level with l Enlighten. Yngli Green Energy Americas, Inc. info@yingliamericas.com Tel:+1 (888)686-8820 YIN ALAR YINGLISOLAR.COM/US NYSE:YGE U9. Y I N G L I S O L A R.COM/U S I Yi n g G Americas O Yrngli Groan Energy Holding Co.Ltd, I YGEZ60CeUS.ri s2o 12 E 201206 01 U.S.Soccer Powered by Yngli solar GreenTriplex GreenTriplex PM245P0 I (245 - 260Wp) Electrical Data Dimensions mm[inch) PM245PO I Typ.Nominal Power PN 245W 250 W 255 W 260 W anvr. �(38�.77o1 � ay.vew }{ Us 1 Typ.module Efficiency 15.2% 155% 15.8% 16.1% II Typ.NominalVohageV.q(V) 30.3 30.6 30.8 31.2 Typ.Nominal Current I.,p(A) 8.09 8.17 8.28 834 Multi-Crystalline Typ.Open CircuitVoltageV«(V) 37.2 37.4 37.6 37.7 Photovoltaic Module Typ.Short Circuit Current kc(A) 8.64 8.69 8.76 8.83 Maximum Tolerance of R. 0/+3% 1639 (64sz1 �•••_• _�• nC irnuftc-lWO m'w 9u ai Utim AM 13,umpe 25122•C In acmrdn wide FN 60901.3 �.•• • Power Range 245-260WpTheri.r„a.�aem.�, 6d,l a d a.�Mf re.w�.r�, d-Ac.,n,ti-.daIM-kh . '�� • • _ e,rs:ptw..(n.The.urod-ap.,brmed, dxs.car �••• •� •,••• .,•� � - Temperature Coefficient •�• �• NOCT 46±2°C • Tem T rature Coefficient of PN -0.44%/K ' YP• Pe •`•` 4` Highly Strengthened Design Typ.Temperature Coefficient olVoc -0.32%/K a,d,vew v `` !•; Module complies with advanced loading tests to Temperature Coefficient of Isc 0.04%/K ........................... meet 2400 Pa loading requirements T 115 4.,,«.., :�_ •r�oet:N.r..l op.r.�,eda.per,..< nor.rn .d�vr dm 800wn„ m•.An i s.>M u,�rn.,2 •cw d W d I M nit w Yru=n e.:' (0.853 112.91] •:,�♦♦♦♦ �.�..�, Mechanical Characteristics us71 ♦♦ w IP-67 Rated function Box Dimensions(L x W x H) 1639 x 983 x 40 mm(64.53 x 38.70 x 157 in) ♦ ♦ ���'•''�� lP Advanced water and dustroof level i `�♦�♦♦�'♦ P Weight 19.Skg(43lbs) [?93n �(1381� s .. yay�♦♦♦♦♦♦ ��� " Front Glass High transparent solar glass(tempered),3.2 mm(0.13 in) 9M.]-) E A.A doss Se<oon . _y��♦♦®♦®♦♦♦♦ ��` Cell 60 muhicrystaline solar cek 156 x 156 mm(6'x 6' Integrated Racking Solution Cell Encapsulation EVA M-" Simplifies installation process and reduces laborBack Sheet Composite film(White) L (-1 N Nda:1 COst9 Frame Anodized aluminum frame(Black) ,�.,''8.,'-% � Junction Box IP-67 rated with 3 bypass diodes y Z- d Cables I x4 mm'(0.04 x 0.16 inch'),length:each 1.0 m(39.37 in) 6 D ConnectorType TycoPV4 H.1-4 PV CYCLEare Operating Conditions I-V Curve I•Vo vendif.lradonce 9.0 OperatingTemperaare 40-+85'C 1 .0 - 0 AmbientTemperature Range -40-+45°C 6 a Max System Voltage UL 1000V ¢ 5'0 .500 WJm' Serial Fuse Rating ISA 10 400 m xa Maximum Surface Load Capacity Tested up to 2400 Pa according to UL 1703 1.0 200xNrn' 0.00 5 10 15 20 35 30 35 10 Warranties and Certifications V.*e(V) ®T�p,l3rd o ProductWarranty Maximum 10 years for material and workmanship Cy re rclrolrage cfuncter sties with dependence o..rad{fie and module tempe atu f o •••" Performance Guarantee Guaranteed output of 90%for 10 years and 80%for 2S years ------ - - F?d F2. I f1 C� De trrP n2. Certifications According to UL 1703 guidelines 'abase.orfinn.dr ,rvinu.nwih.6roul d.A- 1 Packing configuration i J3 J Container 2V GP 40'GP 40•HQ • - f FOR f:0 E l%UIViF'LiANCt y s Pieces per pallet 36 26 36 �L•�;�_,r��[r J Pallets per container d 14 28 � • �flj.G// .r s Pieces per container ISS 364 728 l Dealer Stamp AU Optronics Corporation ■ No.1,Li-Hsin Rd.2•Hsinchu Science Park.Hsinchu 30078,1aiwan BenQ Tel:+886-3-500-8899 E-mail:BenQSolar@auo.com www.BenQSofarcom = • BenQ r Solar BenQ Solar is a division of AU Optronics Tw da.d•.p.Ra..a s.yst Solar ®CWr*-rhy 2013 Au op:,. Corp.A9�n-­­d!,f,­ , TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions D1fik�CNSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA®STC ISM 240 TSM-245 ISM 250 TSM-255 TSM-260 PA05.18 PADS.18 PA05.18 PA05.18 PADS.18 941mm Peak Power watts-P,.rA.(wp) 240 245 250 255 260 Power Output Tolerance-PH.Ax I%) 0/+3 0/+3 0/+3 0/+3 0/+3 w+rcm+ m Maximum Power voltage-vMr(V) 29.7 30.2 30.3 30.5 30.7 o Be` o Maximum PowerCurrent-herr(A) 8.10 8.13 8.27 8.36 8.47 TSM - PAO5 .18 ; a.rr Open Circuit voltage-vac(V) 37.3 37.5 37.6 37.7 37.9 <osxiz Irmurra r.ar Short Circuit Current-Isc(A) $.62 8.68 8.85 8.42 9.00 Module Efficlency rim(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE STC:Irradiance 1000 w/m',Cell Temperature 250C.Air Mass AMI.5 according to EN 60904-3. E Average efficiency reduction of 4.5%o1200 w/m'occarding to EN 60904-1. a N 3 3 ELECTRICAL DATA C NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 'PA05.18 6OA Maximum Power-P� wp) 174 178 181 184 188 Maximum Power Voltage-Vm (V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE A A Maximum Power Current-l-e(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME "-0"" f Open Circuit Voltage(V).VocIV) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 812mm 180 NOCT:Irradiance at 800 w/m AmDlenl Temperature 200C,Wind Speed I m/s. 240 26OW Bock View POWER OUTPUT RANGEMECHANICAL DATA Our most versitile product 11 ® • Compatible with all major BOS components and system Solar cells Multicrystolline 156 x 156 mm(6 inches) .r designs Cell orientation 60 cells(6.10) /�• [� Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1-57 inches) Vw % Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY Glass High transparency solar glass 3.2 mm(0.1 3 inches) r One of the industry's most trusted modules Backsheet While • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with Trinamount Groove • Field proven performance I-V CURVES OF PV MODULE TSM-245 J-Box IP 65 or IP 67 rated I: 0~ 317Q -- Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), POWER OUTPUT GUARANTEE 9W 00mm(43.3 inches) 8°0 Connector OriginolMC4 7.a Wow/m, Highly reliable due to stringent quality control <6.a m 5. As a leading global manufacturer • Over 30 in-house tests(UV,TC, HE and many more) 4.W TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements 3°` products,we believe close 2." 200w/m' Nominal Operating Cell 45OC(t2°C) Operalional Temperature -40-+85°C cooperation with our partners ls-1 Temperature(NOCT) Maximum System t000vDC(IEC)! is critical to success. With local 0040 1o.- 209° 30ao m� Temperature Coefficient of PmAx -0.43%!°C Voltage 600V DC(UL) presence around the globe.Trina is Temperature Coefficient of voc -0.32%/'C Max Series Fuse Ratpv I�� able to provide exceptional service vatage(vJ �� r;�O Temperature Coefficient of Isc 0.047 ' �.:"°+"'"� to each customer in each market Certified to withstand challenging environmental l��� cull Ting iaepa ent and supplement our innovative, Is»r; reliable products with the backingconditions of Trina as a strong,bankable ® i30 km/hr wind load (2400 Pa) WARRANTY partner. We are committed 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty i -'' t JAN 21 2014 • to building strategic,mutually 1:�__------- -y .1 beneficial Collaboration with 25 year Linear Power Warranty I GU p NCE installers,developers,distributors (Pleaserefer toproduct warrantyfor details) E`fIL + , POR GOO and other partners as the / y� backbone of our shared success in CERTIFICATION ��� 'I'o" driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY ;� dewed �y A. Co. ACKAGING CONFIGURATION 10 Year Product Warranty 25 Year Linear Power Warranty <:e� rr �.� Modules per box:24 pieces TrIna Solar Limited r w �C cO Modules per 40'container:672 pieces www.irinasolar.com ;,loom • C �L os P _ _ 3 Addilio011st[o V d a1 value fr • 0% b 9ar}t Trina SOlars lineal t'`'arraf7fy . CAJT Ou.READ SAFETY AND INSTALLATION INS BEFORE USING THE PRODUCT. @yz pTr�nasolar 7 Tr�nasolar 02019'rOo5olarLimited.Allrightsreserved.SpecificationsincludedinthisdolasheeforesubjeCttotiO 80% than ewithout notice.Smart Energy Together Years 5 1a 15 20 25 Smart Energy TogetherI�114PSW ■ I; ,-!an.i,:; ■ Ttina Solar I Virtustvii Module en a ReneSfla 245W, 250W, 255W, 260W irtUS IIDimensions O • • 39.2 Inches l.6 inches 39.1 inches l0 100 m., 245W, 250W, 255W, 260W a.� BODyp/m' _ � eaownn' 1. 400WIrW I)A"\ b rden r, High Module Conversion Efficiencies 2 2oow,m' I I $ OO® a OO 0 ° 10 1a a1 ?b 90 as b GROOVE Vor"M e,syayulc� ZepCompatible � so31-m..•- Irradiation � orrw a.rew Inadln.oe mow/m+ enow/m+ SWIN1.0 WW/ms w001111/mt - Drawing Only for Reference F9ldesstr 1SJ% 162% 162% 16.1% 16.0% _ Mechanical Load Capability of up to 5400 Pa Electrical Characteristics STC JC245M-24/Bb s r Maximum Power(Pmax) 245 W 256 W 255 W 260 W F1 Conforms with IEC 61215:2005, Power Tolerance o-+SW o-+sw o-+SW o-+sw 3ttc 6® IEC 61730:2004,UL 1703 PV Standards MaximumPoweodule y 1522 ISM1SA15.7% 16.0% 1 Maximum Powe Cunem(imp) L39 A s31 A 8.39 A 653 A Maximum Power Voltage(VmD) 299 V 30.1 V 30A V 305 V Short Circuit Current(Hc) 8.73A L83 896A 99SA Open Circuit Voltage(Voc) 375 V 37A V 375 V 37.6 V Values at Standard Test Condmom STC(Air Mass AM1.5,Irradiance 1000W/m,,Cell Temperature 25°C) c.ronmaar. IS09001,OHSAS18001,IS014001 Certified Electrical Characteristics NOCT JC24SM-24/Bb t .t Maximum Power(Pmax) Iffi w 18S W 189 W 193 W Maximum Power Current(Imp) 653 A 637 A 6.63 A 6.74 A _ Maximum Power Voltage(VmD) 279 V 282 V 289 V 29.6 V sarelror�K Application Class A,Safety Class It,Fire Rating C short Circuit Current(Isc) 7.06A 7.12A 720A 7.27A Black also available Open Circuit Voltage(Voc) 35.0V 15.0V 15.1V 35.2V Values at Normal Operating Cell Temperature,Inadlaxe of 800 W/mr,spectrum AM 1.5,ambient temperature 20•C,wind speed 1 m/s Mechanical Characteri G�QC f Ong Cell Type 156.456—Poltvystamne,60(6x10)pes In series Temperature CoefRdent or Voc 430%rc Glass High T.—nisslnn,low Iron,Tempered Glass Temperature Coefficient of 1% 0.041 '_0100% ,f Frame Anodlmd Aluminum Alloy Temperature Coefficient of Pmax -0.e0%/°C e °jny r O -• Junction box IPSS/IP67 rated,with bypass diodes Nominal Operating Cell Temperature(NOCT) 4VCt2'C N 95% m material& Dim—l— •6a.6x39.Ix1.6 Md.es Ad ,N Output Cable 3z AW6,39A/a72 inches m 90% °retl y workmanship _ dlVe Weight 44.16. , 85% Ir.stallatip.Hole Location See Drawing Abor• C U P E R T!N O Parking Information so% te sd. 2 ! Ruildinq Department ! m11nearpower / A EL 0 1 5 10 15 20 25 output <4 Contalner 20'GP AC GP AO'HQ Operating Temperature JO°F-•Ig5°F i 6 N'i 2 e r 14 Pallets per Container 12 n 28 Maximum System VoltageOOV0IC(EDU 6 _ IO00VDC(ut? U YEAR Pieces per Container 300 70D 770 Maximum Series Fuse Rating - 20A([l1)/20A({{OSI {� \ PPPFOIEO PRODUCT VOwVxr�' e•..r.m yatrxeman aelre POam ..m,a,,.,,eeu, 1 `Yr C_.x L i,� i(J I�. L/O U E u U"M P L1 AN C F �. c©l's PV CYCLE - u51ID \ \ �e`�} war- �� WO tcVlfvE?�+ • • ReneSola.com 0 e��dgeesgIl \ CS6P-235/240/245/250/255PX _f CanadianSolar Black-framed eleakthlO Electrical Data STC CS6P-235P CS6P-240P CS6P-245P CS6P-250P C86P-255PX Temperature Characteristics Nominal Maximum Power Pmax) 235W 240W 245W 25OW 255W _ Optimum Operating Voltage(Vmp) 29.6V 29.9V 30.OV 30.1V 30.2VNewEdgPmax .0.43%/'C Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Open Circuit Voltage(Voc) 36.9V 37.OV 37.1V 37.2V 37AV Isc 10.065%/-C Black-framed Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature g5t2°C s Module Efficiency 14.81% 14.92% 15.23% 15.54% 15.85% Operating Temperature -ao°c-.9s•c Performance at Low Irradiance . I t Maximum System Voltage 1000V IEC 1600V UL Industry leading performance at low irradiation Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an Application Classification ClassA irradiance of 1000w/m'to 200w/m' Power Tolerance 0_+5w (AM 1.5,25-C) Next Generation Solar Module Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 end call temperature of 25'C NewEdge,the next generation module designed for multiple - Engineering Drawing S types of mounting systems,offers customers the added NOCT CS6P-235P S6P-240P CS6P-245P CS6P- CS6P- Nominal Maximum Power(Pmax 170W 174W 178W 181W1W 185W5W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27AV 27.5V 27.5V appearance,auto groundingand theft resistance. Optimum Operating Current(imp) 6.27A 6.38A 6.49A 6.60A 6.71A Open Circuit Voltage(Voc) 33.gV 34.OV 34.1V 34.2V 34AV The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal operating cell Temperature,Irradiance o1800 wine,spectnim AM 1.5,ambient temperature 20C. The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data system.The module uses high efficiency poly-crystalline Cell Type _ Poly-crystalline 156 x 156mm,2 or 3 Busbars Key Features silicon cells laminated with a white back sheet and framed CellArrangemenl 60(6 x 10) with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 X 38.7 x 1.57in) • Quick and easy to install = dramatically is the perfect choice for customers who are looking for a high weight 20.5kg(45.2 lbs) reduces installation time quality aesthetic module with lowest system cost. Front cover 3:2mm Tempered glass Frame Material Anodized aluminlum alloy LLUIL • Lower system costs - can cut rooftop J-Box IP65,3 diodes installation costs in half Best Quality Cable 4mm'(IEC)/12AWG(UL),1000mm 42 • 235 quality control points in module production connectors • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects MC4 or MC4 Comparable Standard Packaging(Modules per Pallet) 24pcs with auto leveling and alignment Current binning to improve system performance Module Pieces per container(40 ft.Container) 672pcs(40'HQ) e • Accredited Salt mist resistant • Built-in hyper-bonded grounding system - ifit's I-V Curves (CS6P-255PX) mounted,it's grounded Best Warranty Insurance _ • Theft resistant hardware • 25 years worldwide coverage I I • 100%warranty term coverage Section A•A - — • Ultra-low parts count - 3 parts for the mounting • Providing third party bankruptcy rights and grounding system Non-cancellable a i • Industry first comprehensive warranty insurance by Immediate coverage 1 AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies z i world Comprehensive Certificates • Industry leading plus only power tolerance:0-+5W - — • IEC 61215,IEC 61730, IEC61701 ED2,UL1703, f15 C ERTINO • Backward compatibility with all standard rooftop and CEC Listed,CE and MCS U ground mounting systems IS09001:2008:Quality Management Systemylui►dinCq pepartmenl. 'Specifications included in this datasheet are subject to change without prior notice. ISOITS16949:2009:The automotive quality I 1 • Backed By Our New 10/25 Linear Power Warranty management system +t �nli1/• Plus our added 25 year insurance coverage IS014001:2004:StandardsforEnvironmental L About Canadian Solar r,:a -t management system Canadian Solar Inc. Is one of the world's largest solar Canadian Solar was founded In Canada In 2001 and was 11n Add g• QC080000HSPM:The Certificationfor companies. As a leading vertically-integrated successfully listed on NASDAQ Excharfge,(symbol; C�¢�)_Jr � )E 4,Qi'JihL1NNLE Added Value Fro Hazardous Substances Regulations manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has Vrio'dOle'miltufllc ng gg% m Warranty solar systems, Canadian Solar delivers solar power capacity of 2.CSGW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide P,4,iewe 80% occupational health and safety customers. Canadlan Solar's world class team of e% professionals works closely with our customers to 6 10 1s 20 25 • REACH Compliance provide them with solutions for all their solar needs. Headquarters ,.., vale Avenue West • 10 year product warranty on materials and workmanshipTel 1 519 837 1881 •25 year linear power output warranty r www.canadlansolar.com EN-R•r 10.17 C•eyripM o 2012 Canadlen Selar Inc solar • • � • solar9 � Single Phase Inverters for North America SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US SolarEdge Single Phase Inverters . OUTPUT SE3000A-US I SE380DA-US SESWOA-US I SE6000A-US • Rated AC Power Oulpu[.................... 3000 3800 5000 6000 VA For North America .......... .... ..... 5z 6z�..... ........... ............ ............ Mar-AC Power Output 3300 38W 6000 VA ............................................................................. 5500 240V,277V AC Ou[pW Voltage Min:Nom.-Max• SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US is3-zoA-229Vac.................................................... .................... .... .......................... .............: ACOWpW Voltage Min:Nom.-Max' 2]]-240-264 Vac ..AC DUtpW Vohage Min:Nom:Max' ......................... .......................... ............. ..244_-277-9"c AC Frequency M-n:Nom:Max.' 59.3 60-60.5(with HI country setting 57 60 605) Hz 25 @ 208V/ --, 16@ 203V/ ZS 240V/ Max Continuous Output Current 14 240V €{f 16 @ 240v 23 240V/ 22 @ 277V A .................................................. ................I..........................I.......20 @ 277V.......I..................�....... ............. .GFDI........................................... .......................................................................................................... .....A...... err. Utility Monitoring,Islanding Protection, Country Contfiturable Thresholds Yes 5• INPUT 12,ty.�ri Recommended Max,DCPower••(STC). ._....__._3750 4750 6250 .........7500 ... ..w...... .................. .. .. .. .. ................. ........._...... .... .. •�WaRa, e Transformer-less,Ungrounded Yes ................................................. ...................................... ............................................................... ,ej,aEov� Max mpW Voltage 500 Vdc Nom DC Input Voltage .,. 325 @ 208V/350 @ 240V/400 @ 277VVdc Maz Input Curren[ 11 _ 11.5 I -1B la "c ..Reverse-Polarity Protection................ ....................................................Yes........... .. . Ground-FauH Isolation Detection 600ku Sensitiv' .............................................. .......................... .......................... ......!tY............... .............._....... .. ... Madmum Inverter Elficienry ... 97.8 97.7 98.3 98.3 ...%...... .................................. ...................... .......................... ......... .. 97.51209V/ 97.5 @ 240V/ CEC Weighted Efficienry .........97.5 .......98 % _.. % .................................................. .. 98 @ 240V 277y ......98 @ 277y....... ti Nighttime Power Consum tion <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZgBee(optional) STANDARD COMPLIANCE � .. ........... .................011741,UL3699B(Part numbers ending In''U"),.UL]998,CSA 22.2 Grid Connection Standards IEEE1547 .............................................................................................. ............. ......1ion..................................... ............ p Emrssions FCC aR15 class INSTALLATION SPECIFICATIONS .AC output conduit size/AWG rang?...... .....................................3/4"minimum/24-6 AW G............_............._........... ...... DC input conduit size/a of strings/ AWG range 3/4"minimum/]-2 strings/24-6 AWG Dimensions with AC/DC Safety Switch 30.5 x 12.5 x 7/775 x 375 x]72 30.1 x 12.5 x 7.5/775 x 315 x 191 In/mm __(HxWaD)_ Weight with AC/DC Safety.Switch......... .....................51.2/23:?... .................. .....................54.7/2 ....4.7 Ib/.kg.... .... Codn6..................................... .............. ©I Coln— Noise <50 dBA ZMin:Max Operating Temperature -13 to+140/-25 to+60(CAN version-40to+60) 'F/'C The best choice for SolarEd a enabled systems �nHe'-'----'--- .. '-'"""' ............. ProtectionRating............................ ..............................................NEMA 3R.......... ................................................. — Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance(part numbers ending in"-U") •r,,,m,,,, „d�„ay,,,,m,,,r,so,,,ty,.,�,,,, - Superior efficiency(98%) ... •u"h°°etn`r°`"'°"'.,,"`°"'.'ro• .°ter""°",[,”`a'ea"".`nsc"e."n,°"r'""°�'�.r°`ro urr ret.an xlpde b ae omrq tit•ro mvmrrt - Small,lightweight and easy to install on provided bracket — Built-in module-level monitoring cUp� TING — Internet connection through Ethernet or Wireless "- - „�,- - Outdoor and indoor installationen' — Fixed voltage inverter,DC/AC conversion only _fi, y. wilding D pa'i'l rtm, - — Pre-assembled AC/DC Safety Switch for taster installation sa,nsr>�c USA - GERMANY - ITALY - FRANCE - JAPAN CHINA - ISRAEL AUSTRALIA www.solaredge.us IN 2 1 201y R CODE j� ,CU PLIANCE , �.. • solar " = solar " SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer P300 P350 P400 Module Add-On For North America (for 60-cen PV (for 72-cell PV (for 96cell PV modules) modules) modules) INPUT P300 / P350 / P400 • Rated Input DC Powe r'I 300 350 400 W Absolute Maximum Input Voltage{Vpc at�bwes[temperature) 48 60 80 Vdc .................................................................................................................................. ...................................... MPPT Operating Range 8-48 8-60 8-80 Vdc .............................................................................................................................................................. ............. • Maximum Short Circuit Current(Isc) 10 Adc Maximum DC Input Cunem 12.5 Adc Maximum Emcien 99.5 % Weighted Efficien 98.8 % ........................................................................................ .... ..... ...... r2' Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) _ Maximum Output Current 35 Adc Maximum Output Volta a 60 Vdc • _OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE 2 W • EMC ECC Part35 Class 81 IEC61003-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 ..........................:.....................................................................................(clas....safe......L174................... ............. Ro HS 1 s INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc c. -... ........................................................................... ................................................................................. ............. Dimensions(W x L x H) I 1d1 x 212 x 405/5.55 x 8.34 x 1.59 mm/in Weight(including cables) 950/2.1 gr/Ib ......................................................................................_._........._..-.................................................................... Input Connector MC4/Amphenol/Tyco Ovtput Wire Type/Connector Double Insulated;Amphenol - .................................................................._.................-_......._......................................................................... Output Wire Length.........................................................0-95/3:0..._... ....-.................1.2/_39...................... m/h _ E Operating Temperature Range -40-485/-40-+185 'C/'F Protection Rating....._................................................................................IP65/_N EMAd............................ RelativeHumidity...........................................................-....................._........0.:109......_................._. % .. ...... ............. ^�s.ma sn:oe-v arx moaw.weave a 4e m.ses w.v m,<..Me raea PV SYSTEM DESIGN USING A 50LAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V PV power optimization at the module-level ..Minimum String Length(Power Optimizers) 8 10 IS .... .._........................................................._............__....._......_..............._......T...... Up to 25%more energy Maximum String Length(Power Optimizers) 25 25 50 ............................................I'llu..................................................................................................... ...... Maximum Power per String 5250 _._._..6000.....................12750. .....— Superior efficiency(99.5%) .. ...... .Parallel Strings of Different Lengths or OrientationsYesMi[iga[esalltypesofmodulemisma[chlosses,frommanutacturing[olerancetopartialshading ...."' ������ — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module level voltage shutdown for installer and firefighter safety UPERTI C� USA - GERMANY - ITA.LY - FRANCE - JAPAN CHINA - ISRAEL - AUSTRALIA www.solaredge.usjlf,�lnq Dep ent 2Tl -; SAN 1 M4 UMP IANCE ;"UFS l:UOE C f+T� ,reviewed By