Loading...
B-2017-1928 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: ' CONTRACTOR: • PERMIT NO:B-2017-1928 22430 CUPERTINO RD CUPERTINO,CA 95014-1070(326 50 070) LA SOLAR GROUP INC • VAN NUYS,CA 91406 OWNER'S NAME: PAKNAHAL ALI RAND MESBAHI MOTAHAREH DATE ISSUED: 11/14/2017 OWNER'S PHONE: PHONE NO:(818)359-5868 LICENSED CONTRACTOR'S DECLARATION • BUILDING PERMIT INFO: License Class ROOFING Lic.#974115 Contractor LA SOLAR GROUP INC Date 06/30/2018 X BLDG _ELECT _PLUMB MECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chapter 9(commencing • with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. • JOB DESCRIPTION: (N)22-PANEL ROOF MOUNTED PV SYSTEM(7.6 KW) I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the r formance of the work for which this permit is issued. have and will maintain Worker's Compensation Insurance,as provided for by 'Section 3700 of the Labor Code,for the performance of the work for which this ik. permit is issued. • Sq.Ft Floor Area: Valuation:$30000.00 • APPLICANT CERTIFICATION I certify that I have read this application and state that the above • information is correct.I agree to comply with all city and county ordinances APN Number: Occupancy Type: and state laws relating to building construction,and hereby authorize 326 50 070 representatives of this city to enter upon the above mentioned property for , inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations per the Cue-4ino Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION. Date 11/14/2017 Issued by:Abby Ayende • Date: 11/14/2017 OWNE•-; ILDER DECLARATION I hereby affirm thatl am exempt from the Contractor's License Law for one of the RE-ROOFS; following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is 1. I,as ownerof the property,or my employees with wages as their sole installed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. • sale(Sec.7044,Business&Professions Code) . z. I,as owner of the property,am exclusively contracting with licensed Signature of Applicant: . contractors to construct the project(Sec.7044,Business&Professions Code). Date: 11/14/2017 . I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the - performance of the work for which this permit is issued. HAZARDOUS MATERIALS.DISCLOSURE 2. I have and will maintain Worker's Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this California Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued; maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I Health&Safety Code,Section 25532(a)should I store or handle hazardous • shall not employ any person in any manner so as to become subject to the material. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I Worker's Compensation laws of California. If,after making this certificate of will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 .nd exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety . APPLICANT CERTIFICATION Date: 11/14/2017 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY • correct.I agree to comply with all city and county ordinances and state laws I hereby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of work's for which this permit is issued(Sec.3097,Civ C.) to enter upon the above mentioned property for inspection purposes. (We)agree Lender's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,'and expenses which may accrue against said City in Lender's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I understand my plans shall be used as public records. Signature Date 11/14/2017 Licensed Professional CONSTRUCTION PERMIT APPLICATION k.. ., ' COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 - vz Iy�.. - 2o IT 1617./3 , .,,,:-..F 1 (408) 777-3228 • buildings-cupertin.o.org PEMIT#B- CUPERTINO - REVF DEFT✓ ❑ NEW CONSTRUCTION ❑ADDITION ❑ALTERATION ❑T.J. ❑MEP ❑RE-ROOF ❑SWIMMING POOL/SPA PROJECT ADDRESS APN p '�2-11%0 (up r4ina PO Ad ...613 �� OWNER NAME as C.443 t(4:14G e4wdt. Cf-A f or i,no,i (fl Ccs-614 . ' ' rCONTRACTOR NAME 0 OWNER-BUILDER COMPANY NAME• LICENSE NUMBER LICENSE TYPE IrAct P -Cv L1" 5c1aac Ejr-ovp P-ii s- CNS, c3-7 I . STREET ADDRESS C C' u CITY,STATE, ZIP ' E-MAILPHONE' ,ac �F - . IS ‘join. I) Lj f i C" 4I 4°4 BU4LIC I ❑ARCHITECT ❑.OWNER ❑OWNER AGENT VCONTRACTOR AGENT ENGINEER❑DEVELOPER 0 TENANT CONTACT NAME E-MAIL n ' "beArl,e t -QaOtrir1L.L.e-z . C.{Mcl r 6�,,,,e,2,8 1(Q i cto,,,,.A• co,.., ' ' STREETADDRESS;,, CITY,STATE,ZIP ' PHONE ,, Q '7 i lit--D1- Aut. -1611ZcillS, cc. e/3526 I 01): 77g-a-?-qy • DECRIPTON I ' ' • 141scI L1.1. -2Z 'foole,i5 L Sa l cr Pc.r,et s) 1-4.kid 1 I .I I - IDSIN9LE-FAis;IIII.Y/DU4EX ❑MULTI-FAMILY 0 INDUSTRIAL 0 COMMERCIAL - EXISTING USE •EXISTINGSF' NEW FLOOR SF PORCH SF DECK SF DEMO SF STORIES I TOTAL NET SF USE TYPE OCC SQ.FT. VALUATION(5) I 1 '1 j 'I REMODEL, ,1 1 REMODEL KITCHEN REMODEL OTHR GARAGE ❑ATTACHED ' BATHROOM SF ' SF SF SF 0 DETACHED EXISiNG ❑YESEICHLER.' ❑ YES SECOND STORY ADDITION ❑YES FIRE SPRINKLERS.E NO ;0 NO •❑NO ,DWELLING SECOND DWELLING i❑YES ❑ATTACHED❑DETACHED OTHER UNITS 1: ' UNIT,'DDITON:.! I❑NO SF 1 11 POOLS! ❑ FIBERGLASS 0 VINYL-LINED 0 GUNITE 0 PREFABRICATED POOL 'SF .! 'I SPA-:SF j ,SPA ATTACHED❑YES -❑ NO I TOTAL-SF VBY:I it ' ' REC ED TOTAL VALUATION: I Commercial or Multi Family Buildings with Public Swimming Pools requires Department of Environmental Heath approval RE-ROOF)EXISTING ROOF TYPE: ❑BUILT-UP ROOF❑ASPHALT SHINGLES WOOD SHAKES❑WOOD SHINGLES❑TILE OTHER(SPECIFY)_,.. REMOVE/REPLACE❑NO IF,NO PLYIA'COD ❑w 3/8" PLYWOOD TYPE: PITCH: ROOF CLASS I ' 11❑YES F OF LAYERS THICKNESS Q 5/8" OTHER ❑OSB ❑CDX OTHER •12 A PROPOSED ROOF TYPE:❑BUILT-UP ROOF DASPHALT SHINGLES 0 WOOD SHAKES❑WOOD SHINGLES 0 OTHER I Provide a signed copy of the Cupertino's Tear-Off Policy SF ✓rof SQUARES 1 By my signature below I;certify to each of the following: I am the property,owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree I to comply with all applicable.local ordinances and state laws relating to building construction. .I authorize representatives of Cupertino to tenter the above-identified property for inspection purposes. I acknowledge and authorize all information contained on this application form to be made available for publi 6 :"New SFD/Second Dwelling Units/Multifamily Dwellings:A Demolition permit is required prior to issuance of a building permit for all new construction. 1Commercial,Buildings: Provide a completed Hazardous Materials Disclosure form if any Hazardous Materials are being used as part of this project. ;Copy of Planning Approval Letter or Meeting with Planning prior to submittal of Building Permit application. *HOA-Provide a letter of approval from the Home Owner's Association Bldg,4pp_2017.doc revised 08/01/17 RACKING SPECS SHEET 11 2093165134 Single Family Residence Ara Petrosyan MAP SHEET INDEXCONTRACTOR LA SOLAR GROUP, INC ADDRESS: 16238 B Raymer St., Van Nuys, CA 91406 PHONE: (818) 373-0077 EMAIL: Engineering@lasolargroup.com LIC TYPE: C-46, C-10, C-39 LIC #: 974115 PROPERTY INFORMATION Ara Petrosyan PROPERTY ADDRESS: PARCEL NUMBER: PROPERTY TYPE: OWNER: DRAWN BY: DATE: Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 PHOTOVOLTAIC LAYOUT PROPERTY PLAN ATTACHMENT LAYOUT SHEET 1 SINGLE LINE DIAGRAM CODE REQUIRED SINGNAGE INVERTER DATA SHEET MODULE DATA SHEET MODULE CERTIFICATION RACKING CERTIFICATION AND ATTACHMENT SPECS SHEET 2 SHEET 3 SHEET 4 SHEET 5 SHEET 6 SHEET 7 SHEET 8 SHEET 9 SHEET 10 SHEET 12 GROUNDING & BONDING DETAILS POWER OPTIMIZER DATA SHEET 7.26 kW DC (6.78 kW AC) PHOTOVOLTAIC SYSTEM INSTALLATION ON EXISTING ROOF 22 PANASONIC 330 WATT MODULES WITH P400 POWER OPTIMIZERS, SOLAREDGE 7.6 kW HD WAVE INVERTER ONE STORY HOUSE CONSTRUCTION TYPE: VB OCCUPANCY GROUP: R3 ·2016 California Building Code ·2016 California Residential Code ·2016 California Green Building Standard Code ·2016 California Plumbing Code ·2016 California Mechanical Code ·2016 California Electrical Code ·2016 California Fire Code ·2016 California Energy Code ·2014 International Property Maintenance Code All materials, equipment, installation and work shall comply with the following applicable codes: 2016 CBC / 2015IBC, - 2016 CRC / 2015 IRC, - 2016 CEC / 2014 CEC, - 2016 CMC / 2015 UMC, - 2016CPC/ 2015UPC, - 2016 CFC / 2015IFC, - 2016 Building Energy Efficiency Standards ● Existing plumbing vents, skylights, exhaust outlets, ventilations intake air openings shall not be covered by the solar photovoltaic system. ● All outdoor equipment shall be NEMA 3R rated, including all roof mounted transition boxes and switches. ● All equipment shall be properly grounded and bonded in accordance with CEC article 250. ● All circuits connected to more than one source shall have over current devices located so as to provide over current protection from all sources. [CEC 690.9(A)] ● The utility-interactive inverters shall automatically de-energize its output to the connected electrical production and distribution network upon loss of voltage in the system and shall remain in that state until the electrical production and distribution network voltage has been restored.[CEC 690.61] ● Due to the fact that PV modules are energized whenever exposed to light, PV contractor shall disable the array during installation and service by short circuiting, open circuiting, or covering the array with opaque covering. [CEC 690.1(G)] ● All conductor exposed to weather shall be listed and identified for use in direct sunlight. [CEC 690.31(B), 3i-0.8(D)] ● The module conductors must be type USE-2 or listed for photovoltaic (PV) wire. [CEC 690.31(B)] ● All conductors shall be marked on each end for unique identification. [CEC 690.4 (B)] ● All grounded conductor shall be properly color identified as white. [CEC 200.6] ● PV system connected on the load side of the service disconnecting means of the other source(s) at any distribution equipment on the premises shall meet the following [CEC 705.12(D)]: - Each source connection shall be made at a dedicated circuit breaker or fusible disconnecting means. [CEC 705.12(DX1)] - The sum of the ampere rating of the over current devices in circuits supplying power to the bus bar or conductor shall not exceed 120% of the rating of bus bar or conductor. [CEC 705.12(D)(2)] - The interconnection point shall be on the line side of all ground-fault protection equipment. [CEC 705.12(D)(3)] - Equipment containing over current devices in circuits supplying power to a bus bar or conductor shall be marked to indicate the presence of all sources. [CEC 705.12(D)(4)] - Circuit breaker, if back fed, shall be suitable for such operation. [CEC 705.12(DX5)] ● To minimize overheating of the bus bar in panel board, the panel board main circuit breaker and the PV power source circuit breaker shall be physically located at the opposite end of the bus bar.[CEC 705.12(DX7)] ● Marking and Labeling Methods and Locations. The labels or markings shall be visible after installation. The labels shall be reflective, and all letters shall be capitalized and shall be a minimum height of 9.5 mm (3⁄8 in.) in white on a red background. 690.31 (4) ● Flexible, fine-stranded cables shall be terminated only with terminals, lugs, devices or connector that are identified and listed for such use. [CEC 690.3].(F) & 110.14(A)] ● Connectors shall be of latching or locking type. Connectors that are readily accessible and operating at over 30 volts shall require tool to open and marked "Do Not Disconnect Under Load" or "Not For Current interrupting”. [CEC 690.33(C) & (E)(2)] ● Equipment grounding conductor for PV modules smaller than 6AWG shall be protected from physical damage by a raceway or cable armor. [CEC 690.45 & 250.120(C)] ● Equipment grounding conductor for PV systems without Ground Fault Protection (GFP) and installed on non-dwelling unit must have ampacity of at least 2 times the temperature and conduit fill corrected circuit conductor ampacity, [CEC 690.45(B)] ● Fine-stranded cables used for battery terminals, devices, and connections require lugs and terminals listed and marked for the use. [CEC 690.74 (A)] ● A directory is not required where all inverters and PV disconnecting means are grouped at the main service disconnecting means, since the disconnects would all be located in close proximity to each other. CEC 690.4(D) ● Fuses and Fixed-Trip Circuit Breakers. The standard ampere ratings for fuses and inverse time circuit breakers shall be considered 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000, 1200, 1600, 2000, 2500, 3000, 4000, 5000, and 6000 amperes. 690.9(A) ● Protection devices for PV source circuits and PV output circuits shall be in accordance with the requirements of 690.9(B) through (E). ● Listed PV overcurrent devices shall be required to provide overcurrent protection in PV source and output circuits. The overcurrent devices shall be accessible but shall not be required to be readily accessible. 690.9 (D) ● Equipment that performs the rapid shutdown shall be listed and identified. 690.12 The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B) ● PV source circuits and PV output circuits shall not be contained in the same raceway, cable tray, cable, outlet box, junction box, or similar fitting as conductors, feeders, branch circuits of other non-PV systems, or inverter output circuits, unless the conductors of the different systems are separated by a partition. CEC 690.31(B) ● Direct-Current Photovoltaic Source and Direct-Current Output Circuits on or Inside a Building. 690.31 (G) GENERAL NOTES Abby Ayende 11/08/17 11/08/17 B-2017-1928 Abby Ayende Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale PV SYSTEM AS INDICATED 1 CONTRACTOR: Drawn By : Ara Petrosyan Lic # 974115 Ara Petrosyan N S W E Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 INVERTER INVERTER TYPE: Central: Solar Edge 6.0 kW Inverter Model #SE6000H-US(240V) IN (N) 6.0 kW Inverter SOLAR MODULES ___ Panasonic 330 Watt Model #VBHN330SA16 22 JB (N)Junction Box EMT type Conduit Fire Setback Line INDEX PHOTOVOLTAIC LAYOUT MSP (E) _____ Main Service Panel200A PV ARRAY AC (N) 60A AC Disconnect LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 NOTE: CONDUIT SHALL BE PAINTED TO MATCH EXISTING SURFACE. 1'-6" 1'-6" 1'-6" 3' Array 1 18 Panasonic 330 Watt modules 18 P400 Power Optimizers Tilt: 20 Deg Azimuth: 180 Deg Array 2 4 Panasonic 330 Watt modules 4 P400 Power Optimizers Tilt: 20 Deg Azimuth: 270 Deg AC IN MSP Cupertino Rd., 0 5' 10' J/B AC disconnectInverter 1 1 1 1 1 1 1 1 1 1 12 2 2 2 2 22 22 22 Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 2PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 PROPERTY PLAN IN Inverter LEGEND AC AC Disconnect MSP Main Service Panel Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Cupertino Rd., 0 5' 10' N S W E 130'-1" 119'-9" 34'-10" 46'-7" 36'-9" 61'-10"DRIVEWAY15'-5" MSP IN AC PROPERTY LINE GARAGE Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 3PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 ATTACHMENT LAYOUT MODULES ON ROOF 1 Layer of _________ Plywood & Building Felt DF#2 2"x4" - 24" O.C. SOLAR MODULE 6" ATTACHMENT 20° DF#2 2"x4" Shingle BLOCKING DF#2 2"x6" Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 6' ATTACHMENTS 2" BY 4'' TRUSSES 24" O.C. UNIRAC RAIL NOTE: MAXIMUM ATTACHMENT DISTANCE 6'-0'' Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 4PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 GROUNDING & BONDING DETAILS LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Ara Petrosyan Abby Ayende 11/08/17 5 CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 SINGLE LINE DIAGRAMJ BOX NEMA3R INVERTER SOLAR EDGE 6.0 kW MODEL #SE6000A-US(240V) Solar Edge 6.0 kW Inverter have Integrated DC Disconnect safety switch and Arc Fault Protection (See datasheet on page # 7) (4) #10 AWG PV WIRE INTEGRATED GROUDING FREE IN THE AIR (4) #10 AWG THWN/THWN-2 (1) #8 AWG GND 3/4'' EMT,40 FEET SolarEdge Power Optimizer P400 Rated DC Input Power - 400 watts Maximum Input Voltage - 80 Vdc MPPT Range - 8 to 80 Vdc Maximum Input Current - 12.5 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5250 watts STC per string maximum. Solaredge optimizers have integrated rapid shut down 1 2 11 (3) #8 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT, 6 FEET_____ BUSUTILITY M MAIN METER EXISTING ______ MAIN SERVICE PANEL 120/240V, 1P, 3W NOTE: Service Panel does not contain center fed Main breaker. EXISTING NON CENTER _____ MAIN C/B GROUND ELECTRODE(S) TO BE 5/8 DIAMETER X10'-0'' LONG EMBEDDED A MINIMUM OF 8'-0'' DIRECTLY INTO SOIL PER ART. 250.53(G)200A 200A 35AINSTALL ____ 2P CB(PV) INSTALL AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 200A · If there is a cold water bonding and UFER, no additional supplementary rod is required · If there is no UFER, new ground rod shall be installed · If existing ground rod is more than 25 OHM, than a new ground rod shall be installed 60A NON FUSED AC DISCONNECT, LOCKABLE,BLADE TYPE, NEMA3R 120 / 240V (UTILITY REQUIRED) (3) #8 AWG THWN/THWN-2 (1) #8 AWG GND 3/4" EMT, 2 FEET Ara Petrosyan Main Panel Suitable for Back feed - NEC 705.12(D)(3)LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale PV SYSTEM AS INDICATED November 01, 2017 1 2 11 STRING #1 STRING #2 PV ARRAYS STRING#1 - 11 MODULES STRING#2 - 11 MODULES 22 PANASONIC 330 WATT MODULES 1 SOLAR EDGE 6.0 KW INVERTER ALL WIRES WILL BE CONNECTED WITH 600V RATED WIRE NUTS WITH SEALANT. CONNECTORS SHALL BE LOCKING, TOOL TYPE Abby Ayende 11/08/17 6 CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 SIGNAGE POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN : CAUTION North WARNING PLAQUE INVERTER TYPE: Central MAIN SERVICE Ara Petrosyan SIGNAGE PHOTOVOLTAIC REQUIREMENTS PER CALIFORNIA ELECTRICAL CODE ARTICLE 690 PHOTOVOLTAIC SYSTEM DISCONNECT RATED AC OUTPUT CURRENT - 31.25 AMPS AC NORMAL OPERATING VOLTAGE 240 VOLTS WARNING DO NOT TOUCH TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. Marking shall be placed on interior and exterior DC conduit, raceways, enclosures and cable assemblies every 10 ft (3048 mm) within 1 ft (305 mm) of turns or bands and within 1 ft (305 mm) above and below penetrations of roof/ceiling assemblies, walls or barriers. COMBINER / JUNCTION BOX ARRAY WARNING DO NOT TOUCH TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ON OFF DC DISCONNECT (if applicable) DC DISCONNECT INVERTER (if applicable) ON OFF AC DISCONNECT WARNING RATED OUTPUT CURRENT 31.25 AMPS AC NORMAL OPERATING VOLTAGE 240 VOLTS WARNING: PHOTOVOLTAIC POWER SOURCE This lable is to be located adjacent to the PV breaker 36'' to 75'' above the floor or grade level to center of performance meters (IF APPLICABLE) SERVICE METER METER SOCKET (if applicable) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE OPTIONAL SOLAR P.V. ONLY COMBINER PANEL BOARD PV SUB PANEL (if applicable) WARNING PHOTOVOLTAIC SYSTEM - DO NOT RELOCATE THIS BREAKER WARNING ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. Solar Source Only No Other Loads in This panel CEC 690.5(C) CEC 690.14(C)(2) PHOTOVOLTAIC SYSTEM DISCONNECT CEC 690.17 WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. CEC 690.35(F) OPERATING CURRENT 5.7 AMPS OPERATING VOLTAGE 380 VOLTS MAXIMUM SYSTEM VOLTAGE 500 VOLTS SHORT CIRCUIT CURRENT 14.9 AMPS CEC 690.5(C) CEC 690.14(C)(2) PHOTOVOLTAIC SYSTEM DISCONNECT CEC 690.54 WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM CEC 690.64(B)(4) 690.64(b)(7) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 690.56 LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 CEC. 5. MAKINGS, LABELS AND WIRING SIGNS. A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - Tha marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated. 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1. Marking is required on all interior and exterior DC conduit, raceway, enclosures, cable assemblies, and junction boxes, combiner and disconnects. 2. The materials used for marking shall be reflective, weather resistant material suitable for the environment.Minimum 3/8" letter height; all upper case letters Arial or similar font; Red background with wight lettering. 3. Marking shall contain: WARNING: PHOTOVOLTAIC POWER SOURCE. 4. Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location were the disconnect is operated. FIRE DEPARTMENT REQUIREMENTS AS INDICATED PV SYSTEM Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale November 01, 2017 Cupertino Rd., PV SYSTEM DISCONNECT FOR UTILITY OPERATION INVERTER SERVICE POINT & UTILITY METERING SOLAR PHOTOVOLTAIC ARRAY ON ROOF Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 7PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 INVERTER DATA SHEET INVERTER DATA SHEET Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 8PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 POWER OPTIMIZER DATA SHEET POWER OPTIMIZER DATA SHEET Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 9PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 MODULE DATA SHEET MODULE DATA SHEET Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17 Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 10PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 MODULE CERTIFICATION MODULE CERTIFICATION Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17 RACKING SPECS RACKING SPECS Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 11PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17 RACKING CERTIFICATION AND ATTACHMENT SPECS RACKING CERTIFICATION Project Name and Address No. Revision/Issue Date General Notes Project Sheet Date Scale 12PV SYSTEM AS INDICATED CONTRACTOR: Drawn By : Lic # 974115 Ara Petrosyan Ganesh Subramaniam 22430 Cupertino Rd., Cupertino, CA 95014 November 01, 2017 ATTACHMENT SPECS Ara Petrosyan LA Solar Group 16238 B Raymer St., Van Nuys, CA 91406 Phone: (818) 373-0077 LIC TYPE: C-46, C-10, C-39 Abby Ayende 11/08/17