B-2017-2190 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: CONTRACTOR. PERMIT NO:B-2017-2190 10293 S TANTAU AVE CUPERTINO,CA 95014-3546(375 08 007) ECS DESIGN INC SAN JOSE,CA 95126 OWNER'S NAME: NAITO ANDREW H AND JERRICA DATE ISSUED:12/20/2017 OWNER'S PHONE:408-316-1792 PHONE NO:(408)971-6695 LICENSED CONTRACTOR'S DECLARATION B ILDING PERMIT INFO' License Class 8:C-10:C-20 Lic.#746472 Contractor ECS DESIGN INC Date 04/30/2018 X LDG ELECT PLUMB X ECH X RESIDENTIAL_COMMERCIAL I hereby affirm that I am licensed under the provisions of Chartter 9(commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. - JO DESCRIPTION IN TALL(N)MINI SPLIT AC WALL MOUNT SYSTEM I hereby affirm under penalty of perjury one of the following two declarations: 1. I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the Q r performance of the work for which this permit is issued. 2. ¶have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$3500.00 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances APN Number Occupancy Type: and state laws relating to building construction,and hereby authorize 375 08 007 representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments,costs,and expenses which PERMIT EXPIRES IF WORK IS NOT STARTED may accrue against said City in consequence of the granting of this permit. WITHIN 180 DAYS OF PERMIT ISSUANCE OR Additionally,the applicant understands and will comply with all non-point source regulations per the Cupert'no Municipal Code,Section 9.18. 180 DAYS FROM LAST CALLED INSPECTION Signature Date 12/20/2017 Iss ed by Abby Ayende Da e: 12/20/2017 OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the RE-ROOFS. following two reasons: Al roofs shall be inspected prior to any roofing material being installed.If a roof is i. I,as owner of the property,or my employees with wages as their sole ins,ailed without first obtaining an inspection,I agree to remove all new materials for compensation,will do the work,and the structure is not intended or offered for inspection. sale(Sec.7044,Business&Professions Code) 2. I,as owner of the property,am exclusively contracting with licensed Si I i ature of Applicant: contractors to construct the project(Sec.7044,Business&Professions Code). Dat-: 12/20/2017 I hereby affirm under penalty of perjury one of the following three declarations: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER i. I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. HAZARDOUS MATERIALS DISCLOSURE 2. I have and will maintain Worker s Compensation Insurance,as provided for by I have read the hazardous materials requirements under Chapter 6.95 of the Section 3700 of the Labor Code,for the performance of the work for which this alifornia Health&Safety Code,Sections 25505,25533,and 25534. I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the 3. I certify that in the performance of the work for which this permit is issued,I ealth&Safety Code,Section 25532(a)should I store or handle hazardous shall not employ any person in any manner so as to become subject to the ma erial. Additionally,should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District 1 Worker's Compensation laws of California. If,after making this certificate of wil maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and exemption,I become subject to the Worker's Compensation provisions of the the Health&Safety Code,Sections 25505,25533,and 25534. Labor Code,I must forthwith comply with such provisions or this permit shall V be deemed revoked. -0 ner or authorized agent: APPLICANT CERTIFICATION C Da e:12/20/2017 I certify that I have read this application and state that the above information is CONSTRUCTION LENDING AGENCY correct.I agree to comply with all city and county ordinances and state laws I h reby affirm that there is a construction lending agency for the performance relating to building construction,and hereby authorize representatives of this city of ork's for which this perrfiit is issued(Sec.3097 Civ C) to enter upon the above mentioned property for inspection purposes. (We)agree Le der's Name to save indemnify and keep harmless the City of Cupertino against liabilities, judgments,costs,and expenses which may accrue against said City in Le der's Address consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal ARCHITECT'S DECLARATION Code,Section 9.18. I u derstand my plans shall be used as public records. Lic nsed Signature Date 12/20/2017 Pr fessional EP 52'24' 15' 30' 1 st Floor MH 1REVISION TABLENUMBER DATE REVISED BY DESCRIPTIONNO SCALE SHEET: SCALE:ADDRESS:10293 S. TANTAU AVECUPERTINO, CA 95014PROJECT:171014NAITO'S RESIDENCESCOPE OF WORKS: INSTALL NEW MINI-SPLIT HEAT PUMP SINGLE-ZONE WALL MOUNT AIR CONDITIONER SYSTEM. NOTE: ALL DIMENSIONS & SIZE DESIGNATIONS GIVEN ARE SUBJECT TO VERIFICATION ON JOB SITE AND ADJUSTMENT TO FIT JOB CONDITIONS. VICINITY MAP OUTDOOR CONDENSER UNIT INDOOR WALL-MOUNT UNIT DATE: MINI-SPLIT HEAT PUMP ONE-ZONE BRAND: FUJITSU HALCYON OUTDOOR CONDENSER MODEL: ASU24RLB INDOOR WALL MOUNT MODEL: AOU24RLB CONDENSER PAD ELECTRICAL PANEL 12/4/17 Abby Ayende 12/20/17 12/20/17 B-2017-2190 Abby Ayende Submittal Data:24RLB 24,000 BTU Wall Mount Inverter Driven Heat Pump Job Name:______________________________ Date:_______________________________ Location:_______________________________ Approval:____________________________ Engineer:_______________________________ Construction:_________________________ Submitted to:____________________________ Unit #:______________________________ Submitted by:___________________________ Drawing #:___________________________ Reference:______________________________ Model Information Condenser…………………….………….........….……………..…….. AOU24RLB Evaporator………….……………………..………..………………….. ASU24RLB Electrical …………………………………………......... 208/230V AC 1ph-60Hz Available Voltage Range……………………..………….…......… 208/230 +/- 10% Minimum Circuit Ampacity………………………….………......…........…. 17.1 A Max Fuse Size…….…………………………………...................................….. 20A Max Starting Current………………………………….……...………........... 10.5 A Input Power Cooling…………………………………………………..….……..………. 2.40 kW Heating……………………………………………………..………..….…. 1.92 kW Running Current Cooling……………………………………………………..………….…..… 10.5A Heating…………………………………………….…………..………...…….. 8.5A Capacity Nominal Cooling………………….…………...…………….……….. 24,000 Btu/h Min-Max Cooling……………………………………...…...... 3,100 – 25,000 Btu/h Nominal Heating…………………………….…….…...…………....... 24,000 Btu/h Min-Max Heating……………………...…………………..… 7,500 – 27,000 Btu/h Compressor……………………………………..…..............…… Rotary (inv x1) Motor Output……………………………………….…..……….………… 1,000 W Refrigerant…………………………………………..…………….…………. R410a Charge……..………………………………………….………...………… 3lbs. 1oz Oil…………………………………………………………..……… FREOL ɑ68SZ Fan Motor (Condenser) Type: DC ……………………….………..............……... Propeller x 1 (Condenser) Motor Output …………………………………….…..………….. 49 W (Evaporator) Type: DC……………….……………………….…. Cross flow fan x1 (Evaporator) Motor Output…………………………………………………… 42 W Thermal Protection (On)……………..........................….. 248 ± 27°F (120 ± 15°C) Evaporator (Off)………….……………...........… 302 ± 27°F (150 ± 15°C) Condenser (On) 203 ± 18°F (95 ± 10°C) / (Off) 212 ± 27°F (100 ± 15°C) Heat Exchanger Dimensions (H x W x D) in.(mm)…………….….. 23-2/16 x 34-11/16 x 1-7/16 (620x790x290) Fin Pitch……………………………………...…..……….…….….….…….. 20 FPI Rows x Stages……………………………….…....……….……....…………. 2 x 28 Pipe Type (Material)………....………………………….....….……...…….. Copper Fin Type (Material)……………………………...…….......................…. Aluminum Note: Specifications are based on the following conditions: Cooling: Indoor temperature of 80°F (26.7°C) DB/67°F (19.44°C) WB, and outdoor temperature of 95°F (35°C) DB/75°F (23.9°C) WB. Heating: Indoor temperature of 70°F (21.11°C) DB/59°F (15.°C) WB, and outdoor temperature of 47°F (8.33°C) DB/43°F (6.11°C) WB. Pipe length: 24ft. 7in. (7.5m), Height difference: 0ft. (0m) (Outdoor unit – indoor unit) (*Standard warranty/**10 year warranty/***12 year warranty) Operation Temperature Range Cooling…………...………….………………....…… 14°F (-10°C) - 115°F (-46°C) Heating………………………………………....……… 5°F (-15°C) - 75°F (-24°C) Efficiency SEER………………………………………..…………….........…..……….…… 18 EER (cooling)……….……………………...…………………...……. 2.93 kW/kW COP (heating)……………………………...……………………….… 3.65 kW/kW HSPF (heating)………………………………...................................… 10.6 Btu/hW Enclosure (Condenser) Material……………………………..…...........….……….. Painted galvanized steel Color………......……………………..………...….……. Beige (10 YR 7.5/1.0 NN) Sound Pressure Level Condenser…………………………………………....………………..…. 54 dB (A) Evaporator……….………………………………...…………………..… 47 dB (A) Dimensions H x W x D Condenser in. (mm)….....................….. 24-7/16 x 31-1/8 x 11-7/16 (620x790x290) Evaporator in. (mm)...................................….. 12-5/8 x 39-5/16 x 9 (320x998x228) Connection Pipe Liquid……………………...…………………..…..…..…..............................… 1/4” Gas………………………..….....……………………..….…………………..... 1/2” Method (Liquid/Gas)…….…………...…..........….....…..…...…………..… Brazing Max Length (Pre-charge)………....………….....….… 65ft. (20m) / (49 ft. {15m}) Max Height Difference……………………………..………………….. 49 ft. (15m) Weight Condenser………………..…………………….......………............... 86 lbs. (39 kg) Evaporator…………..…….………….…..……........…….……….... 31 lbs. (14 kg) Accessories Wired Remote Controller……………………..………………….… UTY-RVNUM Wired Remote Controller……………………..….………………… UTY-RNNUM Simple Remote Controller……………………..…………………… UTY-RSNUM Configuration Heating only or cooling only field settings required. Intertek©ETL Number AOU24RLB……………………………………………………………….…. 91987 ASU24RLB………………………………………………..………………… 91986 Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 www.fujitsugeneral.com General Features 1 of 2 ·Standard Warranty: 5 years parts, 7 years compressor. Applies to systems purchased before June 1st 2015* ·Extended Warranty: 10 years parts, 10 years compressor. Systems that have been installed on or after June 1st 2015 by licensed contractors and the online Product Registration has been submitted.** ·Elite Contractor Extended Warranty: 12 years parts, 12 years compressor. Systems that have been installed on or after June 1st 2015 by contractors who have met requirements and have been approved for elite contractor status plus, the online Product Registration has been submitted. *** ·Wired or wireless remote ·Apple catechin filter ·Energy Star rated ·Sleep timer ·Auto louver: 4-way ·Auto mode ·Economy mode ·Auto changeover *** ** * Abby Ayende 12/20/17 Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 www.fujitsugeneral .com Dimensions:24RLB [Unit: in. (mm)] 2 of 2 The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon logo and name is a trademark of Fujitsu General America, Inc. Copyright 2016 Fujitsu General America, Inc. Fujitsu’s products are subject to continuous improvements . Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. Abby Ayende 12/20/17