Loading...
15030143I�I CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22364 RIVERSIDE DR CONTRACTOR: Al SOLAR POWER PERMIT NO: 15030143 OWNER'S NAME: ROBERTS CATHERINE Y TRUSTEE 3150 ALMADEN EXPW STE 250 DATE ISSUED: 03/23/2015 OWNER'S PHONE: 4082557817 SAN JOSE, CA 95118 PHONE NO: (650) 549-1250 ?I'LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL F] INSTALL 10 ROOF TOP, FLUSH MOUNTED PV MODULES (� // License Class 10 Li.. # �/ b� (3.15KV) Contractor Date / S I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the .yformance of the work for which this permit is issued. pe Sq. Ft Floor Area: Valuation: $10000 have and will maintain Worker's Compensation Insurance, as provided for by APN Number: 35602011.00 Occupancy Type: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction, and hereby authorize representatives of this city to enter 180 DA LED INSPECTION. upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments costs, and expenses which may accrue against said City in consequence of the3 Date: granting of this permit. Additionally, the applicant understands and will com with all non-point source regulations per the Cupertino Municipal Code, Section 9.18. 2 2 Signature Date SCJ �s RE-ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Cl OWNER-BUILDER DECLARATION Signature of Applicant: Date: 1 hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the declarations: Health & Safety Code, Section 25532(a) should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally, should I use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 of the Labor Code, for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by the Health & Safety Code, Sections 2 505 2553 and 25534. Section 3700 of the Labor Code, for the performance of the work for which this `_ Owner or authorized agent: DatelA30& permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit. Additionally, the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code, Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO �� TIFF FQTiMATnR — RITII,DING DIVISION LaiADDRESS: 22364 RIVERSIDE DR DATE: 03/23/2015 REVIEWED BY: MELISSA 7'ermit / t., APN: 356 02 011 BP#: "VALUATION: j$10,000 xPERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex p �. �. 7�rsp. Fee: PENTAMATION SOLAR -RES PERMIT TYPE: USE: $0.00 19 WORK INSTALL 10 ROOF TOP FLUSH MOUNTED PV MODULES 3.15k SCOPE Permit Fee: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, sanitary sewer vistrici acnoot n.*- _:. 1 7L..,.., f: — hn 11 ns. thn .-1;_; ... ) ;nfnrma/inn availahle and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff' 7.7%73) "i,<< , Plumb. Plan Check Elec. Plan Check 7'ermit / t., Plumb. Permit Fe, glee Permit Fee Chher Alech. Insp Other Plumb Insp. 'hher k lec. Insh. Fee: �. �. 7�rsp. Fee: b7,1- i'c, NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, sanitary sewer vistrici acnoot n.*- _:. 1 7L..,.., f: — hn 11 ns. thn .-1;_; ... ) ;nfnrma/inn availahle and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff' 7.7%73) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # $236.00 Alternative Energy System 1PHOTOVRES Photovoltaic System Suppl. PC Fee: Q Reg. OT 0.0 hrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:(D Reg. Q OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: �rtrc7tn� f, 0 Work Without Permit? C) Yes No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure Trm,el Docurnenlation Fees: Strong Motion Fee: IBSEISMICR $1.30 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $2.30 $236.00 TOTAL FEE: $238.30 Revised: 02/14/2015 CUSTOMER INFO: NOTES CONTRACTOR INFO: NAME ROBERTS, CATHERINE 1. 2• PV ARRAYS CONTAIN SERIES (STRING) OF MODULES CONNECTED IN PARALLEL. STRING SHALL BE CONNECTED TOGETHER IN SERIES. PV ARRAY WIRING TO COMBINER IS #10 AWG USE 2 W/FACTORY INSTALLED WAC CONNECTORS OFFICE ADDRESS 22364 RIVERSIDE DRIVE CUPERTINO, CA 95014 3. TO INTERFACE W/ MODULES. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT CopyPHONE 408-255-7817 WIRING. 4. 5. OPTIMIZERS (IF USED) ACT AS REMOTE CONTROL ROOFTOP MODULE LEVEL DC DISCONNECTS. PROVIDE GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND lar SYSTEM INFO: SOLD EQUIPMENT # 6. ELECTRODE PER C.E.C. ARTICLE 250.50 THROUGH 250.86. GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM OF LISTED VALUE ABOVE. ?gxymemrinc. SolarWorld SW 315 XL MODULE mono 10 7. ALL MODULES AND RACKING SHALL BE GROUNDED. RACKING WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD Since 1986 SolarEdge Technologies INVERTER SE380OA-US 1 8. FORMING BOLTS. MODULES WITH WEEB CCR WASHERS AND GROUNDED TO THE RAIL. ALL GROUND AND NEUTRAL CONNECTIONS TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. INVERTER IS LISTED TO UL"UTILITY INTERACTIVE" LIC: ##493623 C-1 O/C -46 Al SOLAR POWER INC. OPTIMIZER Solar Edge P400 10 1 10. ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL BE 6 BE THWN-2. 15025 OXNARD ST 200 COM. CON. Wire W/ EOP 0 11. 12. MAXIMUM DC VOLTAGE DROP FROM MODULE TO INVERTER SHALL BE 1.5% ALL WORK TO COMPLY WITH (2011 NEC) 2013 CALIFORNIA ELECTRIC CODE ARTICLE 690, 2013 CAS VAN N UYS CA 91411 1• CALIFORNIA BUILDING CODE. l ARI F OF CONTEN S- 13. DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSIBLE COMBINER (855) 410-4700.:il'�-� PV00 COVER PAGE 14. 15. BOX OR FUSIBLE DISCONNECT MEANS. EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. ALL LABELS AND MARKING TO FOLLOW ARTICLE 690 (IV). t0 '° g� (If D`a'v' StSUGttu 0( ld a " )' rns duc�n9 COn` (at�On$ OO,S,;k PV01 SITE PLAN 16. 17. THE POINT OF CONNECTION SHALL COMPLY WITH CEC/NEC ARTICLE 690.64(B). ALL METALLIC EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE or,an9 t ete{Tom, a^, r� S01 LAYOUT DETAIL ROOF 1 18. NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL ONLY COPPER (CU) CONDUCTORS SHALL BE USED. STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. 1n9 dt t,Is P\ �e an v The Z amP t os e1d to pf = 3 1 19. 20. THIS INVERTER(S) CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. PROJECT SHALL COMPLY WITH: RE ROO F RE�6 U I RIp 3 �Sb3 • SITE PLAN PLACARD E01 ELECTRICAL DETAIL 2014 NEC, 2013 CEC, 2013 CMC, 2013 CRC, 2013 CBC, 2013 CPC, 2013 CFC 2013 CEES AND LOCAL ORDINANCES REQUIRED E02 SIGNAGE CUP1=RTINO SITE IMAGE: CONTACT & RETURN INFO: BRANCH: a�; � , S.uilding Depar"ent SAN JOSE � y¢ MAR 2 3 2015 PLOT P 150 ALMADEN EXPRESSWAY SUITE 250 �� Ci eKtu BY �EVIEVVEG t -OK C:.,7E COMPLIANCE SAN JOSE CA. 95118 Reviewed By. .�•�� DATE �� 1 � PHONE (669) 33-0775 ,�� 4 PLANNING DEPT CUPERTINO PROJECT COORDINATOR: SUNSHINE HERMAN REV DRAFTER NOTE DATE (669) 721-9403 AM IT A PATEL INITIAL DRAFT 3/18/2015 ' SUNSHINE.H@AISOLARPOWER.NET DESIGNER: NAMEAMIT PATEL C D CONTACT PHONE 669-721-9402 I E CONTACT EMAIL AMIT.P@A1SOLARPOWER.NET (E) SFD O�DR PROPERTY LINE SITE PLAN N SCALE: 1/32" = 1'-0" CONDUIT PENETRATES EAVE INVERTER (E) UTILITY METER & MAIN PANEL JUNCTION BOX LOCATED UNDER ARRAY 3' MIN FIRE PATHWAYS ARRAY # PITCH AZIMUTH DETAILED ON PAGE 1 12 196 S1 -LAYOUT DETAIL 2 0 0 S2 -LAYOUT DETAIL 3 0 0 S3 -LAYOUT DETAIL AlS lar wer.. Since 1986 Lic: #493623 C -10/C-46 GENERAL NOTES INSTALLATIONS OF SOLAR AND ELECTRICAL EQUIPMENT SHALL CONFORM WITH THE NEC 2011 SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE PERMITTING AND INSPECTION OF THE LOCAL JURISDICTIONAL AUTHORITY. ALL WORK SHALL COMPLY WITH CBC 2013. KEY: ---- PROPERTY LINE Q INVERTER --- — CONDUIT RUN su SUBPANEL DRIVEWAY oc DC DISCONNECT SOLAR MODULE ac AC DISCONNECT MSP MAIN SERVICE JUNCTION BOX uM METER ❑N MONITORING UNIT �c LOAD CENTER ROOF OBSTRUCTION SIGNATURE PATRICK DETCHMAN C-10, B & C-46 LICENSE #493623 JURISDICTION BUILDING Cupertino, City of PERMIT 10300 Torre Avenue ADDRESS Cupertino, CA 95014 PHONE (408) 777-3228 SYSTEM OWNER )-iNVAME ROBERTS, CATHERINE kiSIM -Ient 22364 RIVERSIDE DRIVE ADDRESS CUPERTINO, CA 95014 PHONE 408-255-7817 PROJECT NAME ROBERTS—A DESIGNER AMIT PATEL DATE 3/18/2015 DC SIZE 3.15 kW PV01-SITE PLAN NEC 690.5(c) IN %" WHITE LETTERING ON RED BACKGROUND, ON PLACE THIS LABEL ON INVERTER(S) OR NEAR FADE -RESISTANT MATERIAL, REFLECTIVE COATING GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.) ®WARNING® NEC 690.17 lar SHOCKELECTRICAL ' ' PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITIONIF • 'INDICATED,Al?%wernc. NORMALLY• ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE Since 1986 Lic: #493623 C -10/C-46 • • LOCAL AHJ. NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10 MAY -• AND ENERGIZED GENERAL NOTES WARNING® ® ELECTRIC SHOCK HAZARD INSTALLATIONS OF SOLAR AND ELECTRICAL ELECTRICAL SHOCK HAZARD EQUIPMENT SHALL CONFORM WITH THE NEC 201` IF A GROUND FAULT IS INDICATED, ■ • NOT TOUCHSPECIFICALLY ARTICLE 690. AS SUBJECT TO THE NORMALLY GROUNDED CONDUCTORS TERMINALS ON BOTH LINE ■ •■ PERMITTING AND INSPECTION OF THE LOCAL MAY BE UNGROUNDED AND ENERGIZED ■ POSITION ■ IN THE •_EN JURISDICTIONAL AUTHORITY. ALL WORK SHALL COMPLY WITH CBC 2013. ® ® WARNING ■ • • •■ •• ■ • PHOTOVOLTAIC •••' NEC 690.31(E)3 & 4 0,"iiPERYINQ POWER SOURCEPLACE ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' �� h3Uildlng Department Fs. ) �I L CAUTION: SOLAR CIRCUIT IAS x 3 2015 ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS �EVIEWE=L NEC 690.31(E)3 & 4 r�k +v�llE (;UMPLIAAICE TERMINALS ON BOTH THE LINE AND LOAD PLACE ON EXTERIOR/INTERIOR OF ELECTRICAL PANEL R'evip., 4 '/ �y Jam^ �`w SIDE MAY BE ENERGIZED IN THE OPEN POSITION SOLAR ELECTRICAL SYSTEM CONNECTED CAUTION:SIGNATURE WARNING PH • • • NEC 705.12(D) 4 ✓p/` PLACE LABEL ON ALL EQUIPMENT CONTAINING OVER y POWER NEC 690.54 CURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A "INTERACTIVE PLACE THIS LABEL AT POINT OF BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE PATRICK DETCHMAN INTERCONNECTION" (AT MAIN SERVICE PANEL AND SOURCES. C-10, B & C-46 LICENSE #493623 SUBPANEL IF APPLICABLE) -11 JURISDICTION NEC 690.35(F)r- " 0 PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, INVERTER• ' • BUILDING Cupertino, City of DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CAUTION PERMIT CIRCUITS MAY BE EXPOSED DURING SERVICE: RATEDINVERTER OUTPUT CURRENT • ■ 10300 Torre Avenue ®• ®CONTAINS OUTPUT • 1 • MULTIPLE POWER ADDRESS Cupertino, CA 95014 WARNING SOURCESPHONE (408) 777-3228 SHOCKELECTRIC ' ' ■ NEC 690.53 & NEC 690.14(C)(2) SYSTEM OWNER THE ■ CONDUCTORS PLACE THIS LABEL ON ALL PHOTOVOLTAIC DC PHOTOVOLTAIC • ■ ■ DISCONNECTING MEANS (ON INVERTER IF INTEGRATED DC NAME ROBERTS, CATHERINE AND MAY BE ENRGIZED DISCONNECTS AND AT SEPARATE DC DISCONNECT IF NEC 705.12(D)7 APPLICABLE) PLACE THIS LABEL AT P.O.C. TO SERVICE 22364 RIVERSIDE DRIVE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL ( AND ADDRESS ELECTRIC SHOCK HAZARD SOLAR ARRAY DC DISC• SUBPANEL IF APPLICABLE)) CUPERTINO, CA 95014 THE DC CONDUCTORS OF THIS OPERATING PHOTOVOLTAIC SYSTEM ARE UNGROUNDED. . ® ® PHONE 408-255-7817 AND MAY BE ENERGIZED • ' • D ® WARNING ® INVERTER OPERATING • . TO 1 • CONNECTION • ■ PROJECT NAME ROBERTS A OPTIMIZERS REGULATED . • • • • • • 1 Vlts DESIGNER AM IT PATEL - • • • LTAIC• • •VER CURRENT DATE 3/18/2015 SHORT CIRCUIT [Iscl 15 Amps CURRENT • SOURCE POWER DC SIZE 13.15 kW E02 -SIGNAGE F_ J BRAY 1 LAYOUT NOTES: Module - 5/16" LAG BOLTS MUST EMBED 2.5" INTO Number of Modules ROOF STRUCTURAL MEMBERS/RAFTERS Modules - TORQUE ALL 5/16" HARDWARE TO CHANNEL NUT THE FOLLOWING: Module Area SILVER S.S. 10-16 FT -LBS STANDARD RAIL BLACK S.S. 7-9 FT -LBS 0.3 - RAILS CAN MOUNT TO EITHER SIDE OF L Array Deadload FOOT (UPSLOPE VS DOWNSLOPE) Lbs/Sq.Ft. FLASHED L FOOT MOUNTING POINT FOR 18 USE ON COMPOSITION ROOF SURFACES Ave. Point Loading WITH LOW TO MODERATE TILT 5/16" S.S. LAG SCREW WITH Cupertino, City of FLAT WASHER 2.5" MINIMUM RAILS CAN BE LEVELED UP TO 3" USING EMBEDMENT IS STANDARD UP TO TWO LEVELING SPACERS AS ADDRESS SHOWN IN "SERIES 100 RAIL LEVELING" L FOOT BASE , / SEAL PENETRATION AND UNDER BASE WITH APPROPRIATE ROOF SEALANT 2" x 4" ACTUAL SIZE W/ COLLAR TIES 24'-10" COMPOSITION L FOOT CAN BE MOUNTED IN ANY ORIENTATION 5/16" X 1" S.S. BOLT AND SPLIT WASHER 5/16" S.S. FLANGE NUT COMPOSITION ROOF FLASHING 5/8" PLYWOOD SHEATING PENETRATION DETAIL 01 FLASHED L FOOT SERIES 100 MOUNTING DETAIL (TYP) 2 SCALE: NTS 26'-2" STEP 3: PLACE L FOOT ON TOP OF FLASHING AND TIGHTEN NUT STEP 2: SLIP FLASHING OVER L FOOT BASE STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT 5/8" PLYWOOD ROOF DECKING TYP. COMPETED \NSSPV��\ON NTc ��izGi n! AT LO�fIT�o r✓ 16'-2" I ROOF INFORMATION: ROOF TYPE: COMP RAFTER SIZE: 2x6 RAFTER SPACING: 24 MOUNTING SPACING: 72 ROOF PITCH: 12 DEGREES AZIMUTH: 196 DEGREES Structural Properties Module SolarWorld SW 315 XL mono Number of Modules 10 Modules Module Weight 49.6 LbS Module Area 21.15 Sq. Ft. Racking Weight 0.3 Lbs/Sq.Ft. Array Deadload 2.7 Lbs/Sq.Ft. Number of Mounts 18 Mounts Ave. Point Loading 27.6 Lbs STRUCTURAL SUMMARY 3 SCALE : -NA s, W? REVIEVVEL Reviet S lar were. sin 1986 Lic: #493623 C -10/C-46 GENERAL NOTES INSTALLATIONS OF SOLAR AND ELECTRICAL EQUIPMENT SHALL CONFORM WITH THE NEC 2011 SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE PERMITTING AND INSPECTION OF THE LOCAL JURISDICTIONAL AUTHORITY. ALL WORK SHALL COMPLY WITH CBC 2013. SYMBOL KEY: ® MOUNT ---- RAIL — — RAFTERS ROOF 0 SOLAR MODULE RAIL SPLICE 0.... ® STRING CONFIG. SIGNATURE V PATRICK DETCHMAN C-10, B & C-46 LICENSE #493623 JURISDICTION BUILDING Cupertino, City of PERMIT 10300 Torre Avenue ADDRESS Cupertino, CA 95014 PH 'U 228 r3Uiic:ir'S WN ER NAME ROBERTS, CATHERINE L; 886U9k8E DRIVE ADDRESS;_ ed ICY ✓}� CUPERTI O, CA 95014 PHONE 408-255-7817 PROJECT NAME ROBERTS A DESIGNER AMIT PATEL DATE 3/18/2015 DC SIZE 3.15 kW S01 -LAYOUT ROOF 1 MIN. 1/2" EMT (2) THWN-2 #10 (1) EG #8 ■■■ME ■11M MEM■■■■■■■■■■ ■■■■■■■t1 �� I/ 1 O O O IBJ I-�_�J Rooftop Array OPEN AIR INTO J -BOX SolarWorld SW 315 XL mono VIA STRAIN RELIEF W/ SOLAR EDGE POWER OPTIMIZER P400-2NM4ARM (2) PV WIRE #10 OR EQ (1) EG #8 WEATHERPROOF J -BOX/ - WIRE TRANSITION POINT NEMA 4X MAX PV VOLTAGE & CURRENT: Record low Temp.('F) 33 Voltage Correction Per Nec 690.7: 1:13 Max PV System Voltage (PER NEC 690.7) VCorrection X Voc X # Modules In Series Max PV Continuous Current Per NEC 690.8(A)(1) 1.25 X isc x # Strings MAXIMUM SYSTEM VOLTAGE: NEC2008/2011 requires to use manufacturers Coefficient if available {[(T min °C - 25°C) * V/°C] + Voc} * # of modules in series OCPD SIZING: MIN DC: ISC * 1.56 MIN AC: INV. OUTPUT * 1.25 MAX BACKFEED: NEC2008: [690.64(B)2 NEC2011: 705.12(D)2 MINIMUM BUS BAR OR CONDUCTOR = TOTAL NUMBER OF BREAKERS FEEDING / 1.2 DC SYSTEM CHARACTERISTICS STC SYSTEM 200 Amps SIZE 3150 WATTS SYSTEM Voc OPTIMIZERS REGULATED TO 10 VOLTS SYSTEM 14.0 Amps Vmp OPTIMIZERS REGULATED TO 350 Amps INVERTER OUTPUT CURRENT 16 VOLTS MAX 1.05 REGULATED 500 VOLTS VOLTAGE 16.8 Amps NOMINAL 20 Amps Imp 9.0 AMPS MAX PHONE (408) 777-3228 CURRENT 15 AMPS Optomizer Properties IMAX 15 Amps Vmax 60 VOLTS Voc 1 VOLTS MIN. 1/2" EMT (3) THWN-2 #10 OR EQ (1) GEC/EGC THWN-2 #8 INVERTER: SolarEdge Technologies SE380OA-US AC WIRE SIZE: INVERTER OUTPUT [690.8(A)] (Isc): INV. OUTPUT * 1.25 MIN. AC WIRE AMPACITY: [690.8(a), 690.8(b), 210.19(A)1, 215.2(A), 110.14(C)]: THE MAXIMUM OF: 1. (INV. OUTPUT * 1.25) 2. (INV. OUTPUT) / CONDITIONS OF USE DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP. DC AMPACITY: SOURCE CIRCUIT [690.8(A)(1)] (Isc): Isc * 1.25 OUTPUT CIRCUIT [690.8(A)(2)] (Isc): Isc* 1.25 * # STRINGS MIN. DC WIRE AMPACITY: 1690.8(a), 690.8(b), 210.19(A)1, 215.2(A), 110.14(C)]: THE MAXIMUM OF: 1. (Isc * 1.25) / (CONDITIONS OF USE) 2. (Isc * 1.25 * 1.25) DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP. Conductor Calculations TIE-IN AMPACITY/BUSS BAR 200 Amps EXISTING SOURCE BREAKER SUM 200 Amps MAXIMUM BACKFEED BREAKER 40 Amps DC CURRENT FOR AMPACITY 14.0 Amps ADJUSTED AMPACITY OF #10 WIRE 38.10 Amps INVERTER OUTPUT CURRENT 16 Amps TEMPERATURE CORRECTION 310.60(C)(4) 1.05 FILL DERATE 1 JURISDICTION ADJUSTED AMPACITY 16.8 Amps Min Breaker Size 20 Amps MAX BACKFEED BREAKER 705.12(D) 40 Amps (E) 200A2P MSPZINSCO LOCATED OUTSIDE WALL I'1 200A MAIN 0 240V From Utility PV BACKFEED GEC IN AC EQUIPMENT GROUNDING BUS, IRREVERSIBLY SPLICED TO EXISTING GEC OR BONDED DIRECTLY TO EXISTING GROUNDING ELECTRODE AREA PROPERTIES MAX TEMP [C] 34 CELSIUS MIN TEMP [C] -3 CELSIUS Alk lar Werinc. Since 1986 Lic: #493623 C -10/C-46 GENERAL NOTES INSTALLATIONS OF SOLAR AND ELECTRICAL EQUIPMENT SHALL CONFORM WITH THE NEC 2011 SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE PERMITTING AND INSPECTION OF THE LOCAL JURISDICTIONAL AUTHORITY. ALL WORK SHALL COMPLY WITH CBC 2013. ELECTRICAL KEY: -r"- BREAKER -"- SWITCH El SCREW TERMINAL ® FUSE • SPLICE EARTH GROUND m CHASSIS GROUND GEC EGC SIGNATURE PATRICK DETCHMAN C-10, B & C-46 LICENSE #493623 JURISDICTION BUILDING Cupertino, City of PERMIT 10300 Torre Avenue ADDRESS Cupertino, CA 95014 PHONE (408) 777-3228 SYS -N,w NAME ffi!, W I nt MAI- '223611 RIVERSIDE DRIVE ADDRESS tti<ttS ;'�1 6 i._VVF.U rU Rcr)d -eviowed by PHONE 408-255-7817 PROJECT NAME ROBERTS_A DESIGNER AMIT PATEL DATE 3/18/2015 DC SIZE 3.15 kW E01 -ELECTRICAL DETAIL SITE MAP � LACARD CAUTION: POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PHOTOVOLT1 %I M \ 'tEVIE% RE Al Ula r were. Since 1986 Lic: #493623 C -10/C-46 GENERAL NOTES INSTALLATIONS OF SOLAR AND ELECTRICAL EQUIPMENT SHALL CONFORM WITH THE NEC 2011 SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE PERMITTING AND INSPECTION OF THE LOCAL JURISDICTIONAL AUTHORITY. ALL WORK SHALL COMPLY WITH CBC 2013. CUPERTINO Suilo ng QeD4rtr ent MAR 2 3 2015 EU rUk C::DE COMPLIANCE. lewea by. SIGNATURE PATRICK DETCHMAN C-10, B & C-46 LICENSE #493623 JURISDICTION BUILDING Cupertino, City of PERMIT 10300 Torre Avenue ADDRESS Cupertino, CA 95014 PHONE (408) 777-3228 SYSTEM OWNER NAME ROBERTS, CATHERINE 22364 RIVERSIDE DRIVE ADDRESS CUPERTINO, CA 95014 PHONE 408-255-7817 PROJECT NAME ROBERTS—A DESIGNER AMIT PATEL DATE 3/18/2015 DC SIZE 3.15 kW PLACARD :sz 0 1 a oferEdge-Fewer ®plitnize>' Module Add -On for Noah ArneriCU OP250-1-W 0P300-1tr4V/ JP 400 MV/ OP400-EV OP250-LV I OP300-11rit/ I OP400-MV OP40G-EV INPUT Rated Input DC Power* 250 300 400 400 W Absolute Maximum Input Voltage (Vo 55 75 75 125 ........ ....... ..................... ..................... Vdc MPPTOperatingRange ....... 5-.5.5 ......S-75 ....... 5-75....... •... 15-125 .................. Vdc..... Maximum Short Circuit Current (Isc) of connected PV 10 10 10 7 Adc Module Maximum DC Input Current ........................ .......... 12:5........ .......12:5........ 12:5 ....... ........8.75 ...... Adc ._.. MaximumEfffclency....................................... ............... ....................._ 99:5.... ... .... .......................... 9° .... Weighted!�!......y............................................. ......................................98:8...................................... .../...... Overvoltage Category I II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Maximum Output Current ..................................................................................................................... 15 ................................ Adc Output Voltage 5 - 60 Vdc _Operating OUTPUT DUPING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC610o0-6-2, IEC61000-6-3 Safetx. ....... .... ... IEC621D9-1 (class II safety).• UL1741..................... ........09-1 cuss....... ..LI74. ... ........... Materia[ UL -94 (5 -VAS: UV Resistant .......................... ....... ....Yes .............. ........... ......................................................... ..RoHS INSTALLATION 3PECIFICAT IONS Maximum Allowed System Voltage 1000 Vdc Dimensions(WxLxH� 143x210x45/5.63x8.26x1.75 mm%in . Weight............................................................. :.:....::•: 450/1:p....::....... .................... gr/Ib... Input Connector ................................................ MC4/Tyco /H+S /Amphenol — H4..................... .......... Output WireTjpe Double insulated; Gmm'; MC4 ...1.2/3.9.....1.....1.6/.. OutPutWireLen$h............................................ 0.95.13:D....I....0.95/3.O...l: ... m��` Operating Temperature Range............................................................:�.-t65/ 40-+150.... I......................... �..� .F... Protection Rating ........................... ............... .... I .................. I.. ........ IP55 / NEMA4............1.................. 0100 Relative Humidity.......................................................................................................................... ............ Rated STCpower of the module. Module of up to+595 power tolerance allovred. PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PRASE 20oV THREE PHASE 480V INVERTER Minimum String Length (Power Optimizers) 8........... 8............ 18....... Maximum String Length (Power Optimizers) . .... ... . .. . ................ .... .. . 25........... 25 ..... . .. .........50........ .... .. Maximum Power per String5250 6000 12750 W Parallel Strings of Different Lengths or Orientations I Yes ...............................................I.."..............._. ...... E ; r+ %_ � '• , .✓ I'I `' t_ Y l.� t �!l 115 C _ i � i � 6 Module Add -®o For North America P250 -fie%/ OP30904011W OP40040°J / OP40 -EV PV power optimization at the m. odule-level Up to 25% more energy Superior efficiency (99.590) Q Mitigates all types of module mismatch losses, from manufacturing tolerance to partial' shading Flexible system design for maximum space Litilization Next generation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAIi - CHINA - ISRAEL - AUSTRALIA www.soleredge.us So �=8�_S9flglD PhaSO 9r VGFf0FS for North America SE300DA-US / SE380QA-US / SE5000A-US / SE6000A-US / SE760DA-US/ SE10000A-US/ SE11400A-US For North America SE3E000.4-US j SE380DA-US / SE5000 SE76COA-US/ SEIGGOGA-US/ SE'€14( Y -t Recommended Max. DC Power" 3750 m3000A-US I SE3800A-US I SESOOOR US I sE6000A-US I SE760OA-US SE10000A-US I SE11400A-US ... ...... OUTPUT I ....... ............ .... ...... I ................. 500 ................ ............... Vdc Nom: DClnputi!oltape.......•....... ............ ........... 325@208V1,350_@240V.......•.............•... . ................. Vdc.... Max. Input Current*** Nominal AC Power Output 3000 3800 ...P '.•...95 5000 6000 7600 9980 @ 208V 11400 VA ..... Adc - Reverse-Polarit�r Protection . Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C ' ....•...............................................Y............................. Ground -Fault isolation Detection 600imSensitivity 10000 @240V ............................. ........... _Maxi mumlnverterEfficiencv...... ...97.7... . .... .. Max. AC Power Output 3300 4150 CEC Weighted Efficien 97.S g c1' 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ........................................... Nighttime Power Consumption <2.5 <4 5450 @240V ADDITIONAL FEATURES @240V Su ported c Communication Interfaes AC Output Voltage Min: Nom. -Max. �� �........... Revenue Grade Data, ANSI C32.1..., ..... .109 ......................... ... . ....._ 183 -208 -229 Vac Safety. ............. ........... UL741, UL1699B, UL1998 CSA 2Z:? .. •.. •. �� r Grid Connection Standards . . .... . .................. IEEE1547 Emissions................... ...... ........................ FCC partly cis ss B - ........... AC OutputVoitage Min. -Nom. Max.* ....................................•...._.............................................................................. ✓ AC output conduitsize/AWGrange 3/4""minimum/24-6 AWG � 3/4;minfmum/8-3AWG' ✓ ...... 211-240-264 Vac ✓ d AC Fre9uen y M: n. Norn, Max. 59.3 - 60 - 60S (wlth HI country . .... setting 57: 60; 60.5} Hz Max.'Continuous Output Current • 12.5 16 2a @ 208N 25 I 32 i 4B @ 2 08V 47 5 A 21 Z40V @ ! 42 @ 240V .. ............. I ...................... ._ .................... Utility Monitoring, islanding ........................ ............................................................ .... ..... Protection, Country Configurable Yes For North America SE3E000.4-US j SE380DA-US / SE5000 SE76COA-US/ SEIGGOGA-US/ SE'€14( Y -t Recommended Max. DC Power" 3750 4750 6250 7500 9500 12400 14250 W ..Transformer-fess:Un rounded................................ Y?s ........... ... ...... Max Input Voltage ................ I ....... ............ .... ...... I ................. 500 ................ ............... Vdc Nom: DClnputi!oltape.......•....... ............ ........... 325@208V1,350_@240V.......•.............•... . ................. Vdc.... Max. Input Current*** 16S 208V 73 18 23 I. 33 @ 208V 34.5 Adc ...P '.•...95 l 15:S.Ca@ 240V.1 ............... .............. 3DS Q 240V..�................. Max, inpll shortClrcvitCurrent 30 45 ..... Adc - Reverse-Polarit�r Protection . Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C ' ....•...............................................Y............................. Ground -Fault isolation Detection 600imSensitivity —A higher current sourca may he used; the inverter will limit its input current tothe v.lues stared ' _Maxi mumlnverterEfficiencv...... ...97.7... . .... .. 98.2 953 98:3... ...... ........ ... ........ 98 98...... 'Y.•... CEC Weighted Efficien 97.S g c1' .....98..... 98 97.5 @ 208V 975 97S .......... 97 @ 208V . .. 97S % ................................ ... 98 @ 240V 97.5.9. Zi0V.................... ........... Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES Su ported c Communication Interfaes 85485 85232, Ethemef; ZigBee (o tional r..........Optional.........P.......}...................................... �� �........... Revenue Grade Data, ANSI C32.1..., STANDARD COMPLIANCE Safety. ............. ........... UL741, UL1699B, UL1998 CSA 2Z:? .. •.. •. �� r Grid Connection Standards . . .... . .................. IEEE1547 Emissions................... ...... ........................ FCC partly cis ss B ............. ........... INSTALLATION SPECIFICATIONS AC output conduitsize/AWGrange 3/4""minimum/24-6 AWG � 3/4;minfmum/8-3AWG' DC input conduit size/ # of strings/ WG range 3%4minimum / 1-2 swings / 24-6 AWG Am ... l -A ................................................................................................. 3/4' minimum 11-2 strings / 14-6 AWG Dlmensi ons with AC/DCSafety 3p5x12.5x7/ 30Sx12Sx7S/ ...... .........-........ ........... Switch �HxWxDI x 315 x 775 172 775 x 3J5 x 191 30.5x12.5x10.5/775x315x260 ntrri Weight with AC/DC Safety Swiich ....... 5? :Z! 23_ .. 54.7 f 24:7........ ....... '88.4 / 40.1 ..... : ...... . .. .............. ......................................... Gl? (kg Cooling Naturai Ctrnveciion .......................... I.................. ...fans (user replaceable) ..�SU ..................... Noise .................I...... ... ...............<j5............................... r1BA Min: Max. Operating Temperature :......... -13 to+140/-25 to+60 (CAN version"*** -40 to +601 Range.................... ......................... .. 'F/ `C Protection Rating NEMA 3R . ..................................................... "Ftxother regional setlingsplease contact SoJarEdg support. Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C ' Fordetailed information, refer to httn://mvtvsolaredee.ur/files/odfs/invert do overshlne eu A—df —A higher current sourca may he used; the inverter will limit its input current tothe v.lues stared ' —CAN P/Ns are eligible forthe Ontario Fff and miccoFrr (ml=FIT ems, 5:7 17400At LIS-CALNJ. 27L-��M 11 r6$e PSea L V t� e 5OI u cli glr --"0 C�--ea ZIyZ;M:111� rs Integrated arc fault protection (Type 1} for NEC 21311690.11 compliance Superior efficiency (99%) Small, lightweight and easy to install on provided bracket Built in -module level monitoring e Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only e Pre -assembled AC/DC Safety Switsli for faster installation Optional—revenue grade da% ANSI 012.1 MAR. z 3 2015 KEVIEINEU fUK G,-JDE GMPLIANCE Revlaavecl By. USA z GERMANY - rrALY - FRANCE -JAPAN - CH WA - AUSTRALIA - THE N ETHIE RLAN DS - ISRAEL wwwzola redge. us �'.•f�4",:��� I I' TUV Power controlled: I. TUVRPt 6lana Lowest measuring tolerance in industry �' Every component is tested to meet 3 times IEC requirements J itDesigned to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance tolerance Near, 25 year linear performance warranty and 10 -year product warranty i k' Glass with anti -reflective coating J r.__..JY..V_.'d:11r.. ,.. ,L_ � � ^ :;Ivn-'.s�•li!'!�:�!Yl�il�'i World-class quality Fully -automated production lines and seamless monitoring of the process and mate- rial ensure the qualitythatthe company sets as its benchmarkfor its sites worldwide. SolarWorld Plus -Sorting Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greaterthan or equal to the nameplate rated power. 25 -year linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course of 25 years, a significant added value compared to the two-phase warranties com- mon in the industry, along with our industry first 10 -year product warranty.* *in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty rr < w 2 T of z `C 7,1 solarworld.com x ITI CD �+ z 'C 0 9 a 0 • Qualified, IEC 61215 • Safety tested, IEC 61730 ® • Glowing sand resistance, IEC 60068-2-68 • Ammonia resistance, IEC 62716 • Salt mist corrosion, IEC 61701 • Perladiclnspectlon C us Periodic inspection Ut.1703 I�Dva • Power controlled 11 C FE�I Noma innovation LACUS GREEN CERTIFIED. f , o MC5 � u � > � � 5kMrF<II f' � s Quality modules made in Germany ^^ Sunmodu1e;-,/XL SW 315 MONO (33mm frame) PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)* Maximum power Pmax rrC Open circuit voltage Von 315 WP Maxlmum powerpoint voltage VmPP 45.6 V Short circuit current Isc 36.5 V Maximum power point current ImPP 9.35 A Module efficiency rim 8.71 A 15.79 "STC: 1000 W/m2, 25°C, AM 1.5 1) Measuring tolerance (Pmax) traceable to TUV Rheinland: +/-2% (TUV Power Controlled). THERMAL CHARACTERISTICS NOCT 46 °C TC 0.042 %/"C TC vo V.n -0.304 %/°C TCPmPP -0.43 %/°C Operating temperature -40°C to 85°C I IF v U V 0 4.20 (106.65) 11.53 (292.85) 0 15.73 (39950) Module voltage M Voc 37.8 (961) oo+ -� 4x 00.26 (6.6) 00.35(9) -100.35 00 0 n, 0 N rn m N � m 22 -►I 39.4 (1001) ----+ 1.30 (33) L . 'll All units provided are imperial. S) units provided in pare" .ptheses. 5oIarWorld AG reserves the right to make specificatiortchanges without notice. C, t; C; 171, rrC ran �rT1 cn mO �z PERFORMANCE AT 800 W/mz, NOCT, AM 1.5 Maximum power Pmax 240.9 Wp Open circuit voltage Von 39.8 V Maximum power point voltage VMPP 33.6 V Short circult current I5C 7.77 A Maximum power point currentI 7.18 A Minor reduction in efficiency under partial load conditions at 25°C: at 200 W/m2,100% (+/-2%) of the STC efficiency (10o0 W/m2) is achieved. COMPONENT MATERIALS Cells permodule 72 Cel! type Mono crystalline Cell dimensions 6.17 in x 6.17 in (156.75 x 156.75 mm) Front Tempered glass (EN 12150) Frame Clear anodmi izedalunum Weight 45.2 lbs (20.5 kg) SYSTEM INTEGRATION PARAMETERS Maximum system voltage SC 11/NEC 1000 V Maximum reverse current 25 A Number of bypass diodes 3 Design Loads` Two rail system 113 psf downward 64 psf upward Design Loads* Edge mounting 178 psf downward 23 psf upward *Please refer to the Sunmodule installation Instructions for the details associated with these load cases. ADDITIONAL DATA Powersorting, -0 Wp /+5 Wp J -Box IP65 Module leads PV wire per 1-11.4703 with H4 connectors Module type (uL 1703) 1 Glass Low iron tempered with ARC 0.43 (11) • Compatible with both "Top -Down" and "Bottom" mounting methods • -.& Grounding Locations: -4 locations along the length of the 1.30(33) nT module in the extended flange. �-- 1.14 (29) -� SW-017105US-G 01-2015 cap � �3• _ .: 1 Advancing Renews-ble Te hnology 19 Lug The WEEB Lug consists of a WEEB (Washer, Electrical Equipment Bond), lay -in lug, and hardware. It is used with a solid or stranded 6AWG to 14AWG copper wire, or two 10AWG to 12AWG copper wires, to provide a continuous ground on roof or ground mounted solar systems. Unlike traditional lay -in lugs, the WEEB Lug does not require surface preparation on rail or module to install. The WEEB Lug is installed using a 1/4-20 stainless steel screw which tightens the WEEB, allowing the specialized teeth to embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. The tin-plated Lug assures minimum contact resistance and protection against corrosion. The copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang for easy access when mounted under a PV module. The low profile of the WEEB Lug allows it to be installed in a variety of positions and comes with hardware to mount it to a rail or through a 1/4 inch clearance hole. - Material: 304 stainless steel, tin-plated copper, outdoor rated Low profile design • Multiple equipment ground conductor allowance: One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG y ' • Listed to ANSi/UL 467 by Intertek ETL ��s • Xc'a 4 SOLAR DEPOT 800.822.4041 Contact us at: 04o.m.4700 www!wfe-jic.com Iti QM ($OD) 967-6917 ,? , Advancing renewable Technology er WEEB Washerr Electrical Equipment Bond The WEEB line of products is designed to bond solar PV modules to mounting structures and create an electrical path to ground. WEEBs eliminate the need for older, more costly grounding methods and greatly reduce the amount of labor and materials used in installations. The innovative WEEB design removes the need to run ground wire to each individual module and eliminates the need for surface preparation on anodized aluminum components.' to install, WEEBs are placed between PV modules and mounting rails at clamping points or at bolted connections. When anti -seize is applied and the hardware is tightened down to the appropriate torque spec, the WEEBs' specialized teeth embed into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. When used in conjunction with a WEEB Lug, the entire solar installation becomes safely and reliably grounded: SOLAR. DEPOT 800.822.4041 W3 -iz CUP'ERTINO 13Uildlnn _" • Material: 304 stainless steel • Listed to ANSI -UL 467 by Intertek ETL for use in Ca the ( 2 3 Z015 • Maximum electrical equipment ground conductor sizq;�Dg�dFvr'th 2 WEEBs contacting each module in an assembly: 6AWG k CODE COMPLIANCE • Outdoor rated Reviewed gv Module wattle Mounting Fail Contact us at. 045.24'7.4.700 www.we-fic.com :e Rail FQ Systems Sunmodule% Grounding of module and frame in US and Canada Traditional Grounding Methods: The module can be grounded by connecting hardware and copper wire to the grounding holes using lay in lug. The lug can be fixed; A) Atthe module corner by using a socket head cap screw or B) Atthe hole provided in the flange by using a screw with a serrated washer, a washer and a nut. The module also can be grounded to the rail utilizing the following hardware: C) WEEB-DPF forSolarWorad Sunfix Ground Mouht and Sunfix Plus mounting systems.. D) WEEB-PMC for SolarWorld Sunfix Ground Mount and Professional Solar mounting systems. E) UGC 1 for Unirac Solar Mount mounting system. F) Long Clawfor Panel Claw mounting system. Q Note: These grounding methods have been tested by Intertek Laboratory in accordance to UL 1703 usingSolarWorld`s modules. Recommended components and their appropriate tightening torque for grounding in US Canada. and • ",ti;...wYNviV,a�, ..(•ii4i:I, ,,.• r/�a'•�'••y '4 X'>GD;esc�iption'. teri• `". °a yTlg•,M , .gtorgGee,�:�w:4:il' a,:,• . ,au,;r•' — i.a�VL. .1'1• 35 Ibf-in, 46 WG tr Lay -In lug Ilsco GBL-4DBT 251bf-in, 8 AWG str 20 Ibf- in,10-14AWG sol/str Socket head cap screw 10-24, S/8", Ss 18-8 62 Ibf-in (7.0 Nm) Bolt #6-32, SS Serrated washer M5, ss Washer ID 9/641-, DD 3/8, SS 38 Ibf-in (4.3 Nm) Nut #6-32,55 BurndyWEEB-DPF 121bf-ft(16.3•Nm) GroundingCiip BurndyWEEB-PMC 12 1 bf-ft (16.3 N m) Unirac UGC -1 10 Ibf-ft (13.5 Nm) Grounding Claw I Panel Claw Long Claw 118-20 Ibf-ft (244-271 Nm) hardware Is 1S Ibf-ft (2o Nm). Choose the higherrequiredrequired to ue of tuetorthe he values specified by the Installation guide for grounding and SolarWorid's module torque requirement. www.sclarworld.com m "Ft < s t kr f �i Q T C; r A� Z z 'C 0 , Q Lay -in lug (Module's corner key) Lay -in lug (Module's Flange) C���J 4i fll�jLgl t.'v jt �.11 n �rrn II, ap N) , { r jri ppiJkl'i ji A� (ji lll'!II��1 ,�lu�f�' rii ��5 5.I, i I � � uc 114 19�9fJ(�J Ijlly�" � � •T��I, � r?:' ������.�}' ,�1�1!I�NJI��;Ye;�l UJ1. � !}a';1' {liar"i ti'�'JIj'j �h .r d P, lkLf i.�{j.�y �,�9�1 IidrlrJoi�ld lil���ili(llll�l��{�f�i'4i �Igl�ilf ,J 4�0.V�;.1�11�'��P�J,{�'y.��I�i�IiIIIGflll�l�ll WEEB—DPF WEEB—PMC E F iiiIrr ie�iar� — UGG-1 Long Claw 0 Note: 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. The NEC section 690.43 states, «Exposed non-current carrying metal parts of module frames, equipment, and conductor enclosures shall be grounded in accor- dance with 250.134 or 250.136(A) regardless of voltage.)) 3. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. SOLARWORLD Weturn sunlight into power. FE 0 N N The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight -seal over the life of the system. The Flashed L Foot provides a single fastener flashed to an attachment composition shingle roof with no required cutting of shingles. The L Foot is engineered for maximum adjustability for a clean level installation. • i" slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components (both available with black flashing) • No Cutting of shingles Patent Pending Flashed L Foot in 3 Simple Steps: 1) Locate the rafter and drill the pilot hole 2) Prep and attach the base 3) Set the flashing and attach the L Foot Place order through your SnapNrack distributor, which can be found at www.snapnrack.com/contact Snag rack Flashed L FOot K t As58rnbled ff s(�ai: of '_i!•a s=Cl@Iai: Pa =1 r) Fh:hed i Foot h it i �it s (1" Si la:_er _•:c seoar-el; , Flashed L Foot Kit Assembly HUT L -FOOT, CLEAR 5/SGISX IIN 6OLT'NIiH . Sn7TLOCKWASNER --SNAPNP.ACK L-FOOTBASE Flashed L Foot Kit Dimensions Snag rack (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. O 2013 by SnapNrack PV Mounting System. All rights reserved. OUPERTINO AR 2 3 2015 CUMPLIANCE V ��,,, ,/ 4,0"e n Sunfix Ground Mount: » Use WEER -PMC at end clamp locations to bond solar module frames to module mounting beam. M FFravided Use WEEB-DPF at mid -clamp locations on outer -beams to z bond solar module frames to module mounting beams. Sunfix plus: » Use WEEB-DPF at mid -clamp locations on outer -beams E to bond solar module frames to module mounting beams. rr C Professional Solar: �-rw » Use WEEB-PMC at mid -clamp locations on outer -beams tom T C bond solar module frames to module mounting beams, Unirac SolarMount: » Use UGC -1 at mid -clamp and end -clamp locations on outer -beams to bond solar module frames to module mounting beams. C Panel Claw, Polar Bear: » This Claw is used for PV modules that are not compatible with flange clamp style Claws, The Long Claw attaches C atthe module mounting holes. Please see the module M manufacturer's installation guide for screwtorque speci- n �. fications. Fiolequanrityand rocarli C= Panel Claw, Polar Bear Mgserrated flaggenut WEEO.DPF Mascrratc� SolarWorld flanBenul• Washcr 5olarWorld end clamp spacer WBT--holt Sunfix Ground Mount Module Clamp Sunfix Ground Mount End Clamp qhs Claw Flange SolarWc mid -clan washer SOIarWodd Washer Wag -PMC SolarWor channel Sunfix Plus Module Clamp Unirac solarMount M z m �° s E � rr C Q T C � � C tdU C M n �. r3 C= 0a ��Ig++vu,unr rail tanytype) Mid Dove sildir Professional Solar SolarWorld Mg holt WEEII-QPF SolarWorld plasticbolt guide WEER -PMC QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping D... http://database.ul.com/cgi-bin/XYV/template/LISEXT/lFRAME/sho... 1 of 2 QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels See General information for Mounting Systems, Mouoting Devices Clamping DeviceS..and Ground Lugs for Use with Photovoltaic Modules and Panels SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Flero Ln Suite 200 San Luis Obispo, CA 93401 USA Investigated Investigated for System Fire Cat. for Mechanical Classification No. Bonding Loading (A, B or Q Tested in Combination With Photovoltaic mounting system Series Y N- UL Listed PV Modules: 50 3 E359313 REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235, REC240, REC245, REC250, REC255, REC260, REC265, REC270, all followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3. Hyundai Heavy Industries Co Ltd: HIS-MxxxMG Series - HiS-M210MG, HIS-M213MG, HIS-M215MG, HIS-M218MG, HIS-M220MG, HIS-M223MG, HIS-M225MG, HiS-M228MG, HIS-M230MG, HiS-M233MG, HiS-M235MG, HIS-M238MG, HiS-M240MG, HIS-M243MG, HiS-M245MG, HIS-M248MG, HIS-M250MG, HIS-M253MG, HIS-M255MG, HIS-M258MG, HIS-M260MG, HIS-11263MG, HiS-M265MG, HIS-M268MG, HiS-M270MG; HIS-SxxxMG Series - HIS-S220MG, HIS-S223MG, HIS-S225MG, HIS-S228MG, HIS-S230MG, HIS-S233MG, HiS-S235MG, HIS-S238MG, HIS-S240MG, HIS-S243MG, HiS-S245MG, HIS-S248MG, HIS-S250MG, HiS-S253MG, HiS-S255MG, HIS-S258MG, HIS-S260MG, HIS-S263MG, HIS-S265MG, HiS-S268MG, HIS-S270MG, HiS-S273MG, HiS-S275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd: JCxxxM-24/BB Series - JC200M-24/13b, JC205M-24/13b, JC21014-24/13b, JC215M-24/Bb, JC220M-24/Bb, JC225M-24/13b, JC230M-24/13b, JC235M-24/13b, JC240M-24/13b, JC245M-24/Bb, JC250M-24/13b, JC255M-24/Bb, JC260M-24/13b, JC26SM-24/Bb, JC270M-24/Bb. Series Y N - 100 Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701, MVX-245-60-5-701, MVX-250-60-5-701, MVX-255-60-5-701, MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5-7B1, MVX-240-60-5-7B1, MVX-245-60-5-7131, MVX-250-60-5-7B1, MVX-255-60-5-7B1, MVX-260-60-5-7B1, m MVX-265-60-5-7131; OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800, OPT -265-60-4-800, OPT -270-60-4-800, OPT -275-60-4-800; m c < ' ` ''` ' C':y s OPT -250-60-4-860, OPT -255-60-4-8130, OPT -260-60-4-860, CD r . .:';e - OPT -265-60-4-880, OPT -270-60-4-8130, OPT -275-60-4-8130. Q o:. T C a Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b, C` << C 1/2/2015 8:19 AM Z 0 QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping D... http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho... 1 of 2 QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Page Bottom Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels See General Information for Mount na Systems Mounting Devices Clamping Devices and Ground Luos for Use with Photovoltaic Modules and Panel SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Flero Ln Suite 200 San Luis Obispo, CA 93401 USA E359313 Investigated Investigated for System Fire Cat. for Mechanical Classification No. Bonding Loading (A, B or Q Tested in Combination With Photovoltaic mounting system Series I Y 350 SeriesI Y 100 z M c_ X m m � m rr n � C � x r c rrr 9 N N UL Listed PV Modules: REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235, REC240, REC245, REC250, REC255, REC260, REC265, REC270, all followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3. Hyundai Heavy Industries Co Ltd: HIS-MxxxMG Series - HIS-M210MG, HIS-M213MG, HIS-M215MG, HiS-M218MG, HIS-M220MG, HIS-M223MG, HIS-M225MG, HiS-M228MG, HIS-M230MG, HiS-M233MG, HiS-M235MG, HIS-M238MG, HIS-M240MG, HiS-M243MG, HIS-M245MG, HiS-M248MG, HIS-M250MG, HIS-M253MG, HIS-M255MG, HIS-M258MG, HIS-M260MG, HiS-M263MG, HiS-M265MG, HiS-M268MG, HIS-M270MG; HIS-SxxxMG Series - HIS-S220MG, HIS-S223MG, HIS-S225MG, HIS-S228MG, HIS-S230MG, HIS-S233MG, HiS-S235MG, HIS-S238MG, HIS-S240MG, HIS-S243MG, HiS-S245MG, HIS-S248MG, HIS-S250MG, HiS-S253MG, HiS-S255MG, HIS-S258MG, HIS-S260MG, HiS-S263MG, HiS-S265MG, HiS-S268MG, HIS-S270MG, HiS-S273MG, HIS-S275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd: JCxxxM-24/1313 Series - JC200M-24/Bb, JC205M-24/13b, JC210M-24/13b, JC215M-24/Bb, JC220M-24/13b, JC225M-24/13b, JC230M-24/13b, JC235M-24/6b, JC240M-24/13b, JC245M-24/13b, JC250M-24/Bb, JC255M-24/13b, JC260M-24/13b, JC265M-24/Bb, 3C270M-24/Bb. Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701, MVX-245-60-5-701, MVX-250-60-5-701, MVX-255-60-5-701, MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5-7131, MVX-240-60-5-7131, MVX-245-60-5-7131, MVX-250-60-5-781, MVX-255-60-5-761, MVX-260-60-5-7B1, MVX-265-60-5-781; OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800, OPT -265-60-4-800, OPT -270-60-4-800, OPT -275-60-4-800; OPT -250-60-4-8130, OPT -255-60-4-8130, OPT -260-60-4-8130, OPT -265-60-4-8130, OPT -270-60-4-8130, OPT 275-60-4-8B0. Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b, 1/2/2015 8:19 AM TECHNICAL BULLETIN SOLARWORLD MODULE TYPES May 19, 2014 1 Issue: 1027 Module Typing of SolarWorld Modules SolarWorld has completed the spread of flame fire performance testing of our photovoltaic modules to classify them to the updated UL 1703 standards. When combined with Class A mounting systems our modules meet the photovoltaic fire system rating of Class A. Module Types There are up to 15 different module types classified by UL. Types are defined by their construction characteristics such as glass thickness, EVA thickness, back sheet thickness and fire performance. Testing Criteria For Class A testing (the most stringent) the module is positioned to simulate mounting to a ballasted system or sloped roof at 22 -degrees and exposed to calibrated flame and wind from a standard distance. The flame is continuously applied to the bottom of the module for 10 minutes. Passing Criteria In orderto pass the spread of flame test: M No part of the module can be blown or falloff the deck in the form of flaming or glowing brands ® No portion of the module or roof deckthat forms part of the building can fall away in the form of glowing particles ® The flame cannot spread laterally on the top surface or intermediate channel such as the space between the module and a roof ® Flame may not spread beyond the specified distance: TESTING CLASS Class A Class 8 Class C Results Sunmodule Plus and Pro -Series: Type 1 Sunmodule Pro -Series XL: Type 1 Sunmodule Protect: Type 3 FLAME SPREAD DISTANCE (ft) r 73 FLAME SPREAD DISTANCE (m) WMA 2.4 3.9 When combined with a Class Akm i' !�rstem our modules meet the photovoltaic fire system Class A requirement. m m:' CD rr TECHNICAL BULLETIN m ems n_ `• C tm It O N t-!. N O N D 1.00