15030143I�I
CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 22364 RIVERSIDE DR
CONTRACTOR: Al SOLAR POWER
PERMIT NO: 15030143
OWNER'S NAME: ROBERTS CATHERINE Y TRUSTEE
3150 ALMADEN EXPW STE 250
DATE ISSUED: 03/23/2015
OWNER'S PHONE: 4082557817
SAN JOSE, CA 95118
PHONE NO: (650) 549-1250
?I'LICENSED CONTRACTOR'S DECLARATION
JOB DESCRIPTION: RESIDENTIAL E] COMMERCIAL F]
INSTALL 10 ROOF TOP, FLUSH MOUNTED PV MODULES
(� //
License Class 10 Li.. # �/ b�
(3.15KV)
Contractor Date / S
I hereby affirm that I am licensed under the provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business & Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation, as provided for by Section 3700 of the Labor Code, for the
.yformance of the work for which this permit is issued.
pe
Sq. Ft Floor Area:
Valuation: $10000
have and will maintain Worker's Compensation Insurance, as provided for by
APN Number: 35602011.00
Occupancy Type:
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
PERMIT EXPIRES IF WORK IS NOT STARTED
correct. I agree to comply with all city and county ordinances and state laws relating
WITHIN 180 DAYS OF PERMIT ISSUANCE OR
to building construction, and hereby authorize representatives of this city to enter
180 DA LED INSPECTION.
upon the above mentioned property for inspection purposes. (We) agree to save
indemnify and keep harmless the City of Cupertino against liabilities, judgments
costs, and expenses which may accrue against said City in consequence of the3
Date:
granting of this permit. Additionally, the applicant understands and will com
with all non-point source regulations per the Cupertino Municipal Code, Section
9.18.
2 2
Signature Date SCJ �s
RE-ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
installed without first obtaining an inspection, I agree to remove all new materials for
inspection.
Cl OWNER-BUILDER DECLARATION
Signature of Applicant: Date:
1 hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons:
ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER
I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale (Sec.7044,
Business & Professions Code)
I, as owner of the property, am exclusively contracting with licensed contractors to
HAZARDOUS MATERIALS DISCLOSURE
construct the project (Sec.7044, Business & Professions Code).
I have read the hazardous materials requirements under Chapter 6.95 of the
California Health & Safety Code, Sections 25505, 25533, and 25534. I will
1 hereby affirm under penalty of perjury one of the following three
maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the
declarations:
Health & Safety Code, Section 25532(a) should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's
material. Additionally, should I use equipment or devices which emit hazardous
Compensation, as provided for by Section 3700 of the Labor Code, for the
air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued.
will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance, as provided for by
the Health & Safety Code, Sections 2 505 2553 and 25534.
Section 3700 of the Labor Code, for the performance of the work for which this
`_
Owner or authorized agent: DatelA30&
permit is issued.
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to the Worker's
CONSTRUCTION LENDING AGENCY
Compensation laws of California. If, after making this certificate of exemption, I
become subject to the Worker's Compensation provisions of the Labor Code, I must
I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked.
work's for which this permit is issued (Sec. 3097, Civ C.)
Lender's Name
APPLICANT CERTIFICATION
Lender's Address
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction, and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We) agree to save
ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities, judgments,
costs, and expenses which may accrue against said City in consequence of the
I understand my plans shall be used as public records.
granting of this permit. Additionally, the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code, Section
Licensed Professional
9.18.
Signature Date
CITY OF CUPERTINO
��
TIFF FQTiMATnR — RITII,DING DIVISION
LaiADDRESS:
22364 RIVERSIDE DR
DATE: 03/23/2015
REVIEWED BY: MELISSA
7'ermit / t.,
APN: 356 02 011
BP#:
"VALUATION: j$10,000
xPERMIT TYPE: Building Permit
PLAN CHECK TYPE: Alteration / Repair
PRIMARY SFD or Duplex
p
�. �. 7�rsp. Fee:
PENTAMATION SOLAR -RES
PERMIT TYPE:
USE:
$0.00
19
WORK
INSTALL 10 ROOF TOP FLUSH MOUNTED PV MODULES 3.15k
SCOPE
Permit Fee:
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, sanitary sewer vistrici acnoot
n.*- _:. 1 7L..,.., f: — hn 11 ns. thn .-1;_; ... ) ;nfnrma/inn availahle and are only an estimate. Contact the Dept for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff' 7.7%73)
"i,<< ,
Plumb. Plan Check
Elec. Plan Check
7'ermit / t.,
Plumb. Permit Fe,
glee Permit Fee
Chher Alech. Insp
Other Plumb Insp.
'hher k lec. Insh.
Fee:
�. �. 7�rsp. Fee:
b7,1- i'c,
NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, sanitary sewer vistrici acnoot
n.*- _:. 1 7L..,.., f: — hn 11 ns. thn .-1;_; ... ) ;nfnrma/inn availahle and are only an estimate. Contact the Dept for addn'l info.
FEE ITEMS (Fee Resolution 11-053 Eff' 7.7%73)
FEE
QTY/FEE
MISC ITEMS
Plan Check Fee:
$0.00
1 #
$236.00
Alternative Energy System
1PHOTOVRES Photovoltaic System
Suppl. PC Fee: Q Reg. OT
0.0
hrs
$0.00
PME Plan Check:
$0.00
Permit Fee:
$0.00
Suppl. Insp. Fee:(D Reg. Q OT
0.0
hrs
$0.00
PME Unit Fee:
$0.00
PME Permit Fee:
$0.00
Construction Tax:
�rtrc7tn� f,
0
Work Without Permit? C) Yes No
$0.00
Advanced Planning Fee:
$0.00
Select a Non -Residential
Building or Structure
Trm,el Docurnenlation Fees:
Strong Motion Fee: IBSEISMICR
$1.30
Select an Administrative Item
Bldg Stds Commission Fee: 1BCBSC
$1.00
SUBTOTALS:
$2.30
$236.00
TOTAL FEE:
$238.30
Revised: 02/14/2015
CUSTOMER INFO:
NOTES
CONTRACTOR INFO:
NAME
ROBERTS, CATHERINE
1.
2•
PV ARRAYS CONTAIN SERIES (STRING) OF MODULES CONNECTED IN PARALLEL. STRING SHALL BE
CONNECTED TOGETHER IN SERIES.
PV ARRAY WIRING TO COMBINER IS #10 AWG USE 2 W/FACTORY INSTALLED WAC CONNECTORS
OFFICE
ADDRESS
22364 RIVERSIDE DRIVE
CUPERTINO, CA 95014
3.
TO INTERFACE W/ MODULES.
PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT
CopyPHONE
408-255-7817
WIRING.
4.
5.
OPTIMIZERS (IF USED) ACT AS REMOTE CONTROL ROOFTOP MODULE LEVEL DC DISCONNECTS.
PROVIDE GROUND ELECTRODE SYSTEM FROM INVERTER TO EXISTING MAIN SERVICE GROUND
lar
SYSTEM INFO:
SOLD EQUIPMENT
#
6.
ELECTRODE PER C.E.C. ARTICLE 250.50 THROUGH 250.86.
GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE MINIMUM OF
LISTED VALUE ABOVE.
?gxymemrinc.
SolarWorld SW 315 XL
MODULE
mono
10
7.
ALL MODULES AND RACKING SHALL BE GROUNDED. RACKING WITH TIN PLATED DIRECT BURIAL
RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD
Since 1986
SolarEdge Technologies
INVERTER
SE380OA-US
1
8.
FORMING BOLTS. MODULES WITH WEEB CCR WASHERS AND GROUNDED TO THE RAIL.
ALL GROUND AND NEUTRAL CONNECTIONS TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL.
INVERTER IS LISTED TO UL"UTILITY INTERACTIVE"
LIC: ##493623 C-1 O/C -46
Al SOLAR POWER INC.
OPTIMIZER
Solar Edge P400
10
1
10.
ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ALL CONDUCTORS IN CONDUIT SHALL
BE 6
BE THWN-2.
15025 OXNARD ST 200
COM. CON.
Wire W/ EOP
0
11.
12.
MAXIMUM DC VOLTAGE DROP FROM MODULE TO INVERTER SHALL BE 1.5%
ALL WORK TO COMPLY WITH (2011 NEC) 2013 CALIFORNIA ELECTRIC CODE ARTICLE 690, 2013
CAS VAN N UYS CA 91411 1•
CALIFORNIA BUILDING CODE.
l
ARI F OF CONTEN S-
13.
DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSIBLE COMBINER
(855) 410-4700.:il'�-�
PV00
COVER PAGE
14.
15.
BOX OR FUSIBLE DISCONNECT MEANS.
EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE.
ALL LABELS AND MARKING TO FOLLOW ARTICLE 690 (IV).
t0 '°
g� (If D`a'v' StSUGttu 0( ld a " )'
rns duc�n9 COn` (at�On$ OO,S,;k
PV01
SITE PLAN
16.
17.
THE POINT OF CONNECTION SHALL COMPLY WITH CEC/NEC ARTICLE 690.64(B).
ALL METALLIC EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE
or,an9 t
ete{Tom, a^, r�
S01
LAYOUT DETAIL
ROOF 1
18.
NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL
ONLY COPPER (CU) CONDUCTORS SHALL BE USED. STRANDED OR SOLID WITH PROPERLY RATED
CONNECTORS.
1n9 dt t,Is P\ �e an v
The Z amP t os
e1d to pf = 3 1
19.
20.
THIS
INVERTER(S) CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE.
ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS.
PROJECT SHALL COMPLY WITH:
RE ROO F RE�6 U I RIp 3
�Sb3
• SITE PLAN PLACARD
E01
ELECTRICAL DETAIL
2014 NEC, 2013 CEC, 2013 CMC, 2013 CRC, 2013 CBC, 2013 CPC, 2013 CFC
2013 CEES AND LOCAL ORDINANCES
REQUIRED
E02
SIGNAGE
CUP1=RTINO
SITE IMAGE:
CONTACT & RETURN INFO:
BRANCH:
a�;
� , S.uilding Depar"ent
SAN JOSE
�
y¢
MAR 2 3 2015
PLOT P
150 ALMADEN EXPRESSWAY
SUITE 250
�� Ci eKtu BY
�EVIEVVEG t -OK C:.,7E COMPLIANCE
SAN JOSE CA. 95118
Reviewed By. .�•�� DATE �� 1 �
PHONE (669) 33-0775
,��
4
PLANNING DEPT
CUPERTINO
PROJECT COORDINATOR:
SUNSHINE HERMAN
REV
DRAFTER
NOTE
DATE
(669) 721-9403
AM IT
A
PATEL
INITIAL DRAFT
3/18/2015
'
SUNSHINE.H@AISOLARPOWER.NET
DESIGNER:
NAMEAMIT
PATEL
C
D
CONTACT PHONE
669-721-9402
I
E
CONTACT EMAIL
AMIT.P@A1SOLARPOWER.NET
(E) SFD O�DR
PROPERTY
LINE
SITE PLAN N
SCALE: 1/32" = 1'-0"
CONDUIT PENETRATES EAVE
INVERTER
(E) UTILITY METER & MAIN PANEL
JUNCTION BOX LOCATED UNDER ARRAY
3' MIN FIRE PATHWAYS
ARRAY #
PITCH
AZIMUTH
DETAILED ON PAGE
1
12
196
S1 -LAYOUT DETAIL
2
0
0
S2 -LAYOUT DETAIL
3
0
0
S3 -LAYOUT DETAIL
AlS lar
wer..
Since 1986
Lic: #493623 C -10/C-46
GENERAL NOTES
INSTALLATIONS OF SOLAR AND ELECTRICAL
EQUIPMENT SHALL CONFORM WITH THE NEC 2011
SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE
PERMITTING AND INSPECTION OF THE LOCAL
JURISDICTIONAL AUTHORITY. ALL WORK SHALL
COMPLY WITH CBC 2013.
KEY:
---- PROPERTY LINE Q INVERTER
--- — CONDUIT RUN su SUBPANEL
DRIVEWAY oc DC DISCONNECT
SOLAR MODULE ac AC DISCONNECT
MSP MAIN SERVICE JUNCTION BOX
uM METER ❑N MONITORING UNIT
�c LOAD CENTER
ROOF OBSTRUCTION
SIGNATURE
PATRICK DETCHMAN
C-10, B & C-46 LICENSE #493623
JURISDICTION
BUILDING
Cupertino, City of
PERMIT
10300 Torre Avenue
ADDRESS
Cupertino, CA 95014
PHONE
(408) 777-3228
SYSTEM OWNER
)-iNVAME
ROBERTS, CATHERINE
kiSIM -Ient
22364 RIVERSIDE DRIVE
ADDRESS
CUPERTINO, CA 95014
PHONE
408-255-7817
PROJECT NAME
ROBERTS—A
DESIGNER
AMIT PATEL
DATE
3/18/2015
DC SIZE
3.15 kW
PV01-SITE PLAN
NEC 690.5(c)
IN %" WHITE LETTERING ON RED BACKGROUND, ON
PLACE THIS LABEL ON INVERTER(S) OR NEAR
FADE -RESISTANT MATERIAL, REFLECTIVE COATING
GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.)
®WARNING®
NEC 690.17
lar
SHOCKELECTRICAL
' '
PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITIONIF
• 'INDICATED,Al?%wernc.
NORMALLY•
ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO REQUIREMENTS BY NEC AND THE
Since 1986
Lic: #493623 C -10/C-46
• •
LOCAL AHJ. NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17, 690.53,690.35(F), 690.54, 690.64(B)(7) and 705.10
MAY -• AND
ENERGIZED
GENERAL NOTES
WARNING® ®
ELECTRIC SHOCK HAZARD
INSTALLATIONS OF SOLAR AND ELECTRICAL
ELECTRICAL SHOCK HAZARD
EQUIPMENT SHALL CONFORM WITH THE NEC 201`
IF A GROUND FAULT IS INDICATED,
■ • NOT TOUCHSPECIFICALLY
ARTICLE 690. AS SUBJECT TO THE
NORMALLY GROUNDED CONDUCTORS
TERMINALS ON BOTH LINE ■ •■
PERMITTING AND INSPECTION OF THE LOCAL
MAY BE UNGROUNDED AND ENERGIZED
■ POSITION ■ IN THE •_EN
JURISDICTIONAL AUTHORITY. ALL WORK SHALL
COMPLY WITH CBC 2013.
® ®
WARNING
■ •
• •■ •• ■
•
PHOTOVOLTAIC •••'
NEC 690.31(E)3 & 4 0,"iiPERYINQ
POWER SOURCEPLACE
ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' ��
h3Uildlng Department
Fs.
) �I
L
CAUTION: SOLAR CIRCUIT IAS
x 3 2015
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
�EVIEWE=L
NEC 690.31(E)3 & 4
r�k +v�llE (;UMPLIAAICE
TERMINALS ON BOTH THE LINE AND LOAD
PLACE ON EXTERIOR/INTERIOR OF ELECTRICAL PANEL R'evip.,
4 '/
�y Jam^ �`w
SIDE MAY BE ENERGIZED IN THE OPEN
POSITION
SOLAR ELECTRICAL SYSTEM CONNECTED CAUTION:SIGNATURE
WARNING
PH • • •
NEC 705.12(D) 4
✓p/`
PLACE LABEL ON ALL EQUIPMENT CONTAINING OVER
y
POWER
NEC 690.54 CURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A
"INTERACTIVE
PLACE THIS LABEL AT POINT OF BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE
PATRICK DETCHMAN
INTERCONNECTION" (AT MAIN SERVICE PANEL AND SOURCES.
C-10, B & C-46 LICENSE #493623
SUBPANEL IF APPLICABLE)
-11
JURISDICTION
NEC 690.35(F)r-
" 0
PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX,
INVERTER• ' •
BUILDING
Cupertino, City of
DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED
CAUTION
PERMIT
CIRCUITS MAY BE EXPOSED DURING SERVICE:
RATEDINVERTER OUTPUT CURRENT • ■
10300 Torre Avenue
®•
®CONTAINS
OUTPUT • 1 •
MULTIPLE POWER
ADDRESS
Cupertino, CA 95014
WARNING
SOURCESPHONE
(408) 777-3228
SHOCKELECTRIC ' ' ■
NEC 690.53 & NEC 690.14(C)(2)
SYSTEM OWNER
THE ■ CONDUCTORS
PLACE THIS LABEL ON ALL PHOTOVOLTAIC DC
PHOTOVOLTAIC • ■ ■
DISCONNECTING MEANS (ON INVERTER IF INTEGRATED DC
NAME
ROBERTS, CATHERINE
AND MAY BE ENRGIZED
DISCONNECTS AND AT SEPARATE DC DISCONNECT IF NEC 705.12(D)7
APPLICABLE) PLACE THIS LABEL AT P.O.C. TO SERVICE
22364 RIVERSIDE DRIVE
DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL ( AND
ADDRESS
ELECTRIC SHOCK HAZARD
SOLAR ARRAY DC DISC• SUBPANEL IF APPLICABLE))
CUPERTINO, CA 95014
THE DC CONDUCTORS OF THIS
OPERATING
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED.
.
® ®
PHONE
408-255-7817
AND MAY BE ENERGIZED
• ' • D
® WARNING ®
INVERTER
OPERATING • . TO 1 • CONNECTION • ■
PROJECT NAME
ROBERTS A
OPTIMIZERS REGULATED
. • • • • •
• 1 Vlts
DESIGNER
AM IT PATEL
- • • • LTAIC•
•
•VER CURRENT
DATE
3/18/2015
SHORT CIRCUIT [Iscl 15 Amps
CURRENT
• SOURCE
POWER
DC SIZE
13.15 kW
E02 -SIGNAGE
F_
J
BRAY 1 LAYOUT
NOTES:
Module
- 5/16" LAG BOLTS MUST EMBED 2.5" INTO
Number of Modules
ROOF STRUCTURAL MEMBERS/RAFTERS
Modules
- TORQUE ALL 5/16" HARDWARE TO
CHANNEL NUT
THE FOLLOWING:
Module Area
SILVER S.S. 10-16 FT -LBS
STANDARD RAIL
BLACK S.S. 7-9 FT -LBS
0.3
- RAILS CAN MOUNT TO EITHER SIDE OF L
Array Deadload
FOOT (UPSLOPE VS DOWNSLOPE)
Lbs/Sq.Ft.
FLASHED L FOOT MOUNTING POINT FOR
18
USE ON COMPOSITION ROOF SURFACES
Ave. Point Loading
WITH LOW TO MODERATE TILT
5/16" S.S. LAG SCREW WITH
Cupertino, City of
FLAT WASHER 2.5" MINIMUM
RAILS CAN BE LEVELED UP TO 3" USING
EMBEDMENT IS STANDARD
UP TO TWO LEVELING SPACERS AS
ADDRESS
SHOWN IN "SERIES 100 RAIL LEVELING"
L FOOT BASE , /
SEAL PENETRATION AND
UNDER BASE WITH
APPROPRIATE ROOF SEALANT
2" x 4" ACTUAL SIZE
W/ COLLAR TIES
24'-10"
COMPOSITION L FOOT CAN BE
MOUNTED IN ANY ORIENTATION
5/16" X 1" S.S. BOLT
AND SPLIT WASHER
5/16" S.S. FLANGE NUT
COMPOSITION
ROOF FLASHING
5/8" PLYWOOD SHEATING
PENETRATION DETAIL 01 FLASHED L FOOT
SERIES 100
MOUNTING DETAIL (TYP)
2 SCALE: NTS
26'-2"
STEP 3: PLACE L FOOT ON TOP
OF FLASHING AND TIGHTEN NUT
STEP 2: SLIP FLASHING
OVER L FOOT BASE
STEP 1: BOLT L FOOT BASE
TO ROOF WITH LAG BOLT
5/8" PLYWOOD ROOF
DECKING TYP.
COMPETED \NSSPV��\ON
NTc
��izGi n! AT LO�fIT�o r✓
16'-2" I
ROOF INFORMATION:
ROOF TYPE: COMP
RAFTER SIZE: 2x6
RAFTER SPACING: 24
MOUNTING SPACING: 72
ROOF PITCH: 12 DEGREES
AZIMUTH: 196 DEGREES
Structural Properties
Module
SolarWorld SW 315 XL
mono
Number of Modules
10
Modules
Module Weight
49.6
LbS
Module Area
21.15
Sq. Ft.
Racking Weight
0.3
Lbs/Sq.Ft.
Array Deadload
2.7
Lbs/Sq.Ft.
Number of Mounts
18
Mounts
Ave. Point Loading
27.6
Lbs
STRUCTURAL SUMMARY
3 SCALE : -NA
s, W?
REVIEVVEL
Reviet
S lar
were.
sin 1986
Lic: #493623 C -10/C-46
GENERAL NOTES
INSTALLATIONS OF SOLAR AND ELECTRICAL
EQUIPMENT SHALL CONFORM WITH THE NEC 2011
SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE
PERMITTING AND INSPECTION OF THE LOCAL
JURISDICTIONAL AUTHORITY. ALL WORK SHALL
COMPLY WITH CBC 2013.
SYMBOL KEY:
® MOUNT
---- RAIL
— — RAFTERS
ROOF
0 SOLAR MODULE
RAIL SPLICE
0.... ® STRING CONFIG.
SIGNATURE
V
PATRICK DETCHMAN
C-10, B & C-46 LICENSE #493623
JURISDICTION
BUILDING
Cupertino, City of
PERMIT
10300 Torre Avenue
ADDRESS
Cupertino, CA 95014
PH 'U
228
r3Uiic:ir'S WN ER
NAME
ROBERTS, CATHERINE
L;
886U9k8E DRIVE
ADDRESS;_
ed ICY ✓}�
CUPERTI O, CA 95014
PHONE
408-255-7817
PROJECT NAME
ROBERTS A
DESIGNER
AMIT PATEL
DATE
3/18/2015
DC SIZE
3.15 kW
S01 -LAYOUT ROOF 1
MIN. 1/2" EMT
(2) THWN-2 #10
(1) EG #8
■■■ME
■11M
MEM■■■■■■■■■■
■■■■■■■t1 ��
I/ 1 O O O
IBJ I-�_�J
Rooftop Array OPEN AIR INTO J -BOX
SolarWorld SW 315 XL mono VIA STRAIN RELIEF
W/ SOLAR EDGE POWER OPTIMIZER P400-2NM4ARM (2) PV WIRE #10 OR EQ
(1) EG #8
WEATHERPROOF J -BOX/ -
WIRE TRANSITION POINT
NEMA 4X
MAX PV VOLTAGE & CURRENT:
Record low Temp.('F) 33
Voltage Correction Per Nec 690.7: 1:13
Max PV System Voltage (PER NEC 690.7)
VCorrection X Voc X # Modules In Series
Max PV Continuous Current Per NEC 690.8(A)(1)
1.25 X isc x # Strings
MAXIMUM SYSTEM VOLTAGE:
NEC2008/2011 requires to use
manufacturers Coefficient if available
{[(T min °C - 25°C) * V/°C] + Voc} * # of
modules in series
OCPD SIZING:
MIN DC: ISC * 1.56
MIN AC: INV. OUTPUT * 1.25
MAX BACKFEED:
NEC2008: [690.64(B)2
NEC2011: 705.12(D)2
MINIMUM BUS BAR OR CONDUCTOR =
TOTAL NUMBER OF BREAKERS
FEEDING / 1.2
DC SYSTEM CHARACTERISTICS
STC SYSTEM
200
Amps
SIZE
3150
WATTS
SYSTEM Voc
OPTIMIZERS REGULATED TO 10
VOLTS
SYSTEM
14.0
Amps
Vmp
OPTIMIZERS REGULATED TO 350
Amps
INVERTER OUTPUT CURRENT
16
VOLTS
MAX
1.05
REGULATED
500
VOLTS
VOLTAGE
16.8
Amps
NOMINAL
20
Amps
Imp
9.0
AMPS
MAX
PHONE
(408) 777-3228
CURRENT
15
AMPS
Optomizer Properties
IMAX
15
Amps
Vmax
60
VOLTS
Voc
1
VOLTS
MIN. 1/2" EMT
(3) THWN-2 #10 OR EQ
(1) GEC/EGC THWN-2 #8
INVERTER:
SolarEdge Technologies SE380OA-US
AC WIRE SIZE:
INVERTER OUTPUT [690.8(A)] (Isc): INV. OUTPUT * 1.25
MIN. AC WIRE AMPACITY:
[690.8(a), 690.8(b), 210.19(A)1, 215.2(A), 110.14(C)]:
THE MAXIMUM OF:
1. (INV. OUTPUT * 1.25)
2. (INV. OUTPUT) / CONDITIONS OF USE
DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP.
DC AMPACITY:
SOURCE CIRCUIT [690.8(A)(1)] (Isc): Isc * 1.25
OUTPUT CIRCUIT [690.8(A)(2)] (Isc): Isc* 1.25 * # STRINGS
MIN. DC WIRE AMPACITY:
1690.8(a), 690.8(b), 210.19(A)1, 215.2(A), 110.14(C)]:
THE MAXIMUM OF:
1. (Isc * 1.25) / (CONDITIONS OF USE)
2. (Isc * 1.25 * 1.25)
DERATE WIRE FOR TERMINALS DEPENDING UPON TEMP.
Conductor Calculations
TIE-IN AMPACITY/BUSS BAR
200
Amps
EXISTING SOURCE BREAKER SUM
200
Amps
MAXIMUM BACKFEED BREAKER
40
Amps
DC CURRENT FOR AMPACITY
14.0
Amps
ADJUSTED AMPACITY OF #10 WIRE
38.10
Amps
INVERTER OUTPUT CURRENT
16
Amps
TEMPERATURE CORRECTION 310.60(C)(4)
1.05
FILL DERATE
1
JURISDICTION
ADJUSTED AMPACITY
16.8
Amps
Min Breaker Size
20
Amps
MAX BACKFEED BREAKER 705.12(D)
40
Amps
(E) 200A2P MSPZINSCO
LOCATED OUTSIDE WALL
I'1 200A MAIN
0
240V From Utility
PV BACKFEED
GEC IN AC EQUIPMENT
GROUNDING BUS, IRREVERSIBLY
SPLICED TO EXISTING GEC OR
BONDED DIRECTLY TO EXISTING
GROUNDING ELECTRODE
AREA PROPERTIES
MAX TEMP [C]
34
CELSIUS
MIN TEMP [C]
-3
CELSIUS
Alk lar
Werinc.
Since 1986
Lic: #493623 C -10/C-46
GENERAL NOTES
INSTALLATIONS OF SOLAR AND ELECTRICAL
EQUIPMENT SHALL CONFORM WITH THE NEC 2011
SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE
PERMITTING AND INSPECTION OF THE LOCAL
JURISDICTIONAL AUTHORITY. ALL WORK SHALL
COMPLY WITH CBC 2013.
ELECTRICAL KEY:
-r"- BREAKER
-"- SWITCH
El SCREW TERMINAL
® FUSE
• SPLICE
EARTH GROUND
m CHASSIS GROUND
GEC
EGC
SIGNATURE
PATRICK DETCHMAN
C-10, B & C-46 LICENSE #493623
JURISDICTION
BUILDING
Cupertino, City of
PERMIT
10300 Torre Avenue
ADDRESS
Cupertino, CA 95014
PHONE
(408) 777-3228
SYS -N,w
NAME
ffi!, W I nt
MAI-
'223611 RIVERSIDE DRIVE
ADDRESS
tti<ttS ;'�1 6
i._VVF.U rU Rcr)d
-eviowed by
PHONE
408-255-7817
PROJECT NAME
ROBERTS_A
DESIGNER
AMIT PATEL
DATE
3/18/2015
DC SIZE
3.15 kW
E01 -ELECTRICAL DETAIL
SITE MAP � LACARD
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN:
PHOTOVOLT1 %I M \
'tEVIE%
RE
Al Ula r
were.
Since 1986
Lic: #493623 C -10/C-46
GENERAL NOTES
INSTALLATIONS OF SOLAR AND ELECTRICAL
EQUIPMENT SHALL CONFORM WITH THE NEC 2011
SPECIFICALLY ARTICLE 690. AS SUBJECT TO THE
PERMITTING AND INSPECTION OF THE LOCAL
JURISDICTIONAL AUTHORITY. ALL WORK SHALL
COMPLY WITH CBC 2013.
CUPERTINO
Suilo ng QeD4rtr ent
MAR 2 3 2015
EU rUk C::DE COMPLIANCE.
lewea by.
SIGNATURE
PATRICK DETCHMAN
C-10, B & C-46 LICENSE #493623
JURISDICTION
BUILDING
Cupertino, City of
PERMIT
10300 Torre Avenue
ADDRESS
Cupertino, CA 95014
PHONE
(408) 777-3228
SYSTEM OWNER
NAME
ROBERTS, CATHERINE
22364 RIVERSIDE DRIVE
ADDRESS
CUPERTINO, CA 95014
PHONE
408-255-7817
PROJECT NAME
ROBERTS—A
DESIGNER
AMIT PATEL
DATE
3/18/2015
DC SIZE
3.15 kW
PLACARD
:sz 0 1 a oferEdge-Fewer ®plitnize>'
Module Add -On for Noah ArneriCU
OP250-1-W 0P300-1tr4V/ JP 400 MV/ OP400-EV
OP250-LV I OP300-11rit/ I OP400-MV OP40G-EV
INPUT
Rated Input DC Power*
250 300 400 400
W
Absolute Maximum Input Voltage (Vo
55 75 75 125
........ ....... ..................... .....................
Vdc
MPPTOperatingRange
....... 5-.5.5 ......S-75 ....... 5-75....... •... 15-125
..................
Vdc.....
Maximum Short Circuit Current (Isc) of connected PV
10 10 10 7
Adc
Module
Maximum DC Input Current ........................ ..........
12:5........ .......12:5........ 12:5 ....... ........8.75 ......
Adc ._..
MaximumEfffclency.......................................
............... ....................._ 99:5.... ... .... ..........................
9° ....
Weighted!�!......y.............................................
......................................98:8......................................
.../......
Overvoltage Category
I II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER)
Maximum Output Current
.....................................................................................................................
15 ................................
Adc
Output Voltage
5 - 60
Vdc
_Operating
OUTPUT DUPING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 Vdc
STANDARD COMPLIANCE
EMC
FCC Part15 Class B, IEC610o0-6-2, IEC61000-6-3
Safetx.
....... .... ...
IEC621D9-1 (class II safety).• UL1741.....................
........09-1 cuss....... ..LI74. ...
...........
Materia[
UL -94 (5 -VAS: UV Resistant ..........................
....... ....Yes ..............
...........
.........................................................
..RoHS
INSTALLATION 3PECIFICAT IONS
Maximum Allowed System Voltage 1000 Vdc
Dimensions(WxLxH� 143x210x45/5.63x8.26x1.75 mm%in .
Weight............................................................. :.:....::•: 450/1:p....::....... .................... gr/Ib...
Input Connector ................................................ MC4/Tyco /H+S /Amphenol — H4..................... ..........
Output WireTjpe Double insulated; Gmm'; MC4
...1.2/3.9.....1.....1.6/..
OutPutWireLen$h............................................ 0.95.13:D....I....0.95/3.O...l: ... m��`
Operating Temperature Range............................................................:�.-t65/ 40-+150.... I......................... �..� .F...
Protection Rating ........................... ............... .... I .................. I.. ........ IP55 / NEMA4............1..................
0100
Relative Humidity.......................................................................................................................... ............
Rated STCpower of the module. Module of up to+595 power tolerance allovred.
PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PRASE 20oV THREE PHASE 480V
INVERTER
Minimum String Length (Power Optimizers)
8...........
8............
18.......
Maximum String Length (Power Optimizers)
. .... ... . .. . ................ ....
.. .
25...........
25 .....
. ..
.........50........
....
..
Maximum Power per String5250
6000
12750
W
Parallel Strings of Different Lengths or Orientations I Yes
...............................................I.."..............._. ......
E ; r+ %_ � '• , .✓ I'I `' t_ Y l.� t �!l 115 C _ i � i �
6
Module Add -®o For North America
P250 -fie%/ OP30904011W OP40040°J / OP40 -EV
PV power optimization at the m. odule-level
Up to 25% more energy
Superior efficiency (99.590)
Q Mitigates all types of module mismatch losses, from manufacturing tolerance to partial' shading
Flexible system design for maximum space Litilization
Next generation maintenance with module -level monitoring
Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - ITALY - FRANCE - JAPAIi - CHINA - ISRAEL - AUSTRALIA
www.soleredge.us
So �=8�_S9flglD PhaSO 9r VGFf0FS for North America
SE300DA-US / SE380QA-US / SE5000A-US / SE6000A-US /
SE760DA-US/ SE10000A-US/ SE11400A-US
For North America
SE3E000.4-US j SE380DA-US / SE5000
SE76COA-US/ SEIGGOGA-US/ SE'€14(
Y -t
Recommended Max. DC Power" 3750
m3000A-US
I SE3800A-US I SESOOOR US
I sE6000A-US I
SE760OA-US
SE10000A-US
I SE11400A-US
... ......
OUTPUT
I ....... ............ .... ...... I .................
500
................ ...............
Vdc
Nom: DClnputi!oltape.......•....... ............
........... 325@208V1,350_@240V.......•.............•...
.
.................
Vdc....
Max. Input Current***
Nominal AC Power Output
3000
3800
...P '.•...95
5000
6000
7600
9980 @ 208V
11400
VA
.....
Adc -
Reverse-Polarit�r Protection .
Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C '
....•...............................................Y.............................
Ground -Fault isolation Detection
600imSensitivity
10000 @240V
.............................
...........
_Maxi mumlnverterEfficiencv...... ...97.7...
. .... ..
Max. AC Power Output
3300
4150
CEC Weighted Efficien 97.S
g c1'
5400 @ 208V
6000
8350
10800 @ 208V
12000
VA
...........................................
Nighttime Power Consumption
<2.5
<4
5450 @240V
ADDITIONAL FEATURES
@240V
Su ported c
Communication Interfaes
AC Output Voltage Min: Nom. -Max.
��
�...........
Revenue Grade Data, ANSI C32.1...,
.....
.109
.........................
...
. ....._
183 -208 -229 Vac
Safety. ............. ........... UL741, UL1699B, UL1998 CSA 2Z:? .. •.. •. ��
r
Grid Connection Standards
. . .... .
.................. IEEE1547
Emissions...................
...... ........................
FCC partly cis ss B
-
...........
AC OutputVoitage Min. -Nom. Max.*
....................................•...._..............................................................................
✓
AC output conduitsize/AWGrange
3/4""minimum/24-6 AWG � 3/4;minfmum/8-3AWG'
✓
......
211-240-264 Vac
✓
d
AC Fre9uen y M: n. Norn, Max.
59.3 - 60 - 60S (wlth HI country
. ....
setting 57: 60;
60.5}
Hz
Max.'Continuous Output Current •
12.5
16
2a @ 208N
25
I
32 i
4B @ 2 08V
47 5
A
21 Z40V
@
!
42 @ 240V
.. ............. I ......................
._ ....................
Utility Monitoring, islanding
........................
............................................................
....
.....
Protection, Country Configurable
Yes
For North America
SE3E000.4-US j SE380DA-US / SE5000
SE76COA-US/ SEIGGOGA-US/ SE'€14(
Y -t
Recommended Max. DC Power" 3750
4750 6250 7500 9500
12400
14250 W
..Transformer-fess:Un rounded................................
Y?s
...........
... ......
Max Input Voltage ................
I ....... ............ .... ...... I .................
500
................ ...............
Vdc
Nom: DClnputi!oltape.......•....... ............
........... 325@208V1,350_@240V.......•.............•...
.
.................
Vdc....
Max. Input Current***
16S 208V
73 18 23
I.
33 @ 208V
34.5 Adc
...P '.•...95
l 15:S.Ca@ 240V.1 ............... ..............
3DS Q 240V..�.................
Max, inpll shortClrcvitCurrent
30
45
.....
Adc -
Reverse-Polarit�r Protection .
Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C '
....•...............................................Y.............................
Ground -Fault isolation Detection
600imSensitivity
—A higher current sourca may he used; the inverter will limit its input current tothe v.lues stared '
_Maxi mumlnverterEfficiencv...... ...97.7...
. .... ..
98.2 953 98:3...
...... ........ ... ........
98
98...... 'Y.•...
CEC Weighted Efficien 97.S
g c1'
.....98.....
98 97.5 @ 208V
975 97S
..........
97 @ 208V
. ..
97S %
................................
... 98 @ 240V
97.5.9. Zi0V....................
...........
Nighttime Power Consumption
<2.5
<4
W
ADDITIONAL FEATURES
Su ported c
Communication Interfaes
85485 85232, Ethemef; ZigBee (o tional
r..........Optional.........P.......}......................................
��
�...........
Revenue Grade Data, ANSI C32.1...,
STANDARD COMPLIANCE
Safety. ............. ........... UL741, UL1699B, UL1998 CSA 2Z:? .. •.. •. ��
r
Grid Connection Standards
. . .... .
.................. IEEE1547
Emissions...................
...... ........................
FCC partly cis ss B
.............
...........
INSTALLATION SPECIFICATIONS
AC output conduitsize/AWGrange
3/4""minimum/24-6 AWG � 3/4;minfmum/8-3AWG'
DC input conduit size/ # of strings/
WG range 3%4minimum / 1-2 swings / 24-6 AWG
Am
... l -A .................................................................................................
3/4' minimum 11-2 strings / 14-6 AWG
Dlmensi ons with AC/DCSafety 3p5x12.5x7/
30Sx12Sx7S/
...... .........-........
...........
Switch �HxWxDI x 315 x
775 172
775 x 3J5 x 191
30.5x12.5x10.5/775x315x260
ntrri
Weight with AC/DC Safety Swiich ....... 5? :Z! 23_
.. 54.7 f 24:7........
....... '88.4 / 40.1 ..... : ...... .
.. .............. .........................................
Gl? (kg
Cooling Naturai Ctrnveciion
..........................
I..................
...fans (user replaceable)
..�SU .....................
Noise .................I...... ... ...............<j5...............................
r1BA
Min: Max. Operating Temperature
:.........
-13 to+140/-25 to+60 (CAN version"*** -40 to +601
Range.................... ......................... ..
'F/ `C
Protection Rating NEMA 3R . .....................................................
"Ftxother regional setlingsplease contact SoJarEdg support.
Limited to 125%for focationswhare the yearly avenge high tlnpzratora is abov=_for locations where it rs below 77'F/25*C '
Fordetailed information, refer to httn://mvtvsolaredee.ur/files/odfs/invert do overshlne eu A—df
—A higher current sourca may he used; the inverter will limit its input current tothe v.lues stared '
—CAN P/Ns are eligible forthe Ontario Fff and miccoFrr (ml=FIT ems, 5:7 17400At LIS-CALNJ.
27L-��M
11
r6$e PSea L V t� e 5OI u cli glr --"0 C�--ea ZIyZ;M:111�
rs Integrated arc fault protection (Type 1} for NEC 21311690.11 compliance
Superior efficiency (99%)
Small, lightweight and easy to install on provided bracket
Built in -module level monitoring
e Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
e Pre -assembled AC/DC Safety Switsli for faster installation
Optional—revenue grade da% ANSI 012.1
MAR. z 3 2015
KEVIEINEU fUK G,-JDE GMPLIANCE
Revlaavecl By.
USA z GERMANY - rrALY - FRANCE -JAPAN - CH WA - AUSTRALIA - THE N ETHIE RLAN DS - ISRAEL wwwzola redge. us
�'.•f�4",:���
I
I'
TUV Power controlled:
I. TUVRPt 6lana Lowest measuring tolerance in industry
�' Every component is tested to meet
3 times IEC requirements
J
itDesigned to withstand heavy
accumulations of snow and ice
Sunmodule Plus:
Positive performance tolerance
Near, 25 year linear performance warranty
and 10 -year product warranty
i
k' Glass with anti -reflective coating
J
r.__..JY..V_.'d:11r.. ,.. ,L_ � � ^ :;Ivn-'.s�•li!'!�:�!Yl�il�'i
World-class quality
Fully -automated production lines and seamless monitoring of the process and mate-
rial ensure the qualitythatthe company sets as its benchmarkfor its sites worldwide.
SolarWorld Plus -Sorting
Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules
that have greaterthan or equal to the nameplate rated power.
25 -year linear performance guarantee and extension of product warranty to 10 years
SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course
of 25 years, a significant added value compared to the two-phase warranties com-
mon in the industry, along with our industry first 10 -year product warranty.*
*in accordance with the applicable SolarWorld Limited Warranty at purchase.
www.solarworld.com/warranty rr
<
w
2 T
of z
`C 7,1
solarworld.com x
ITI
CD
�+ z
'C
0 9
a 0
• Qualified, IEC 61215
• Safety tested, IEC 61730
® • Glowing sand resistance, IEC 60068-2-68
• Ammonia resistance, IEC 62716
• Salt mist corrosion, IEC 61701
• Perladiclnspectlon C us
Periodic inspection
Ut.1703
I�Dva • Power controlled
11
C FE�I Noma innovation
LACUS GREEN CERTIFIED.
f , o
MC5 �
u � >
� � 5kMrF<II
f' �
s
Quality modules
made in Germany
^^
Sunmodu1e;-,/XL
SW 315 MONO (33mm frame)
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)*
Maximum power
Pmax
rrC
Open circuit voltage
Von
315 WP
Maxlmum powerpoint voltage
VmPP
45.6 V
Short circuit current
Isc
36.5 V
Maximum power point current
ImPP
9.35 A
Module efficiency
rim
8.71 A
15.79
"STC: 1000 W/m2, 25°C, AM 1.5
1) Measuring tolerance (Pmax) traceable to TUV
Rheinland: +/-2% (TUV Power Controlled).
THERMAL CHARACTERISTICS
NOCT
46 °C
TC
0.042 %/"C
TC vo
V.n
-0.304 %/°C
TCPmPP
-0.43 %/°C
Operating temperature
-40°C to 85°C
I
IF
v
U
V
0
4.20
(106.65)
11.53
(292.85)
0
15.73
(39950)
Module voltage M Voc
37.8 (961)
oo+
-� 4x
00.26 (6.6)
00.35(9)
-100.35
00 0 n,
0 N rn
m N �
m 22
-►I 39.4 (1001) ----+
1.30 (33)
L .
'll
All units provided are imperial. S) units provided in pare"
.ptheses.
5oIarWorld AG reserves the right to make specificatiortchanges without notice.
C,
t;
C;
171,
rrC
ran
�rT1
cn
mO
�z
PERFORMANCE AT 800 W/mz, NOCT, AM 1.5
Maximum power
Pmax 240.9 Wp
Open circuit voltage
Von 39.8 V
Maximum power point voltage VMPP 33.6 V
Short circult current
I5C 7.77 A
Maximum power point currentI 7.18 A
Minor reduction in efficiency under partial load conditions at 25°C: at 200 W/m2,100%
(+/-2%) of the STC efficiency (10o0 W/m2) is achieved.
COMPONENT MATERIALS
Cells permodule 72
Cel! type Mono crystalline
Cell dimensions 6.17 in x 6.17 in (156.75 x 156.75 mm)
Front Tempered glass (EN 12150)
Frame Clear anodmi
izedalunum
Weight 45.2 lbs (20.5 kg)
SYSTEM INTEGRATION PARAMETERS
Maximum system voltage SC 11/NEC 1000 V
Maximum reverse current 25 A
Number of bypass diodes 3
Design Loads` Two rail system 113 psf downward
64 psf upward
Design Loads* Edge mounting 178 psf downward
23 psf upward
*Please refer to the Sunmodule installation Instructions for the details associated with
these load cases.
ADDITIONAL DATA
Powersorting, -0 Wp /+5 Wp
J -Box IP65
Module leads PV wire per 1-11.4703 with H4 connectors
Module type (uL 1703) 1
Glass Low iron tempered with ARC
0.43 (11) • Compatible with both "Top -Down"
and "Bottom" mounting methods
•
-.& Grounding Locations:
-4 locations along the length of the
1.30(33) nT
module in the extended flange.
�-- 1.14 (29) -�
SW-017105US-G 01-2015
cap � �3• _ .:
1
Advancing Renews-ble Te hnology
19 Lug
The WEEB Lug consists of a WEEB (Washer, Electrical Equipment Bond), lay -in lug, and hardware. It is
used with a solid or stranded 6AWG to 14AWG copper wire, or two 10AWG to 12AWG copper wires, to
provide a continuous ground on roof or ground mounted solar systems. Unlike traditional lay -in lugs, the
WEEB Lug does not require surface preparation on rail or module to install. The WEEB Lug is installed
using a 1/4-20 stainless steel screw which tightens the WEEB, allowing the specialized teeth to embed
into anodized aluminum, galvanized steel, or any electrically conductive metal to establish a gas tight
electrical connection. The tin-plated Lug assures minimum contact resistance and protection against
corrosion. The copper wire is clamped by a 1/4-28 stainless steel screw, which is horizontal to the tang
for easy access when mounted under a PV module. The low profile of the WEEB Lug allows it to be
installed in a variety of positions and comes with hardware to mount it to a rail or through a 1/4 inch
clearance hole.
- Material: 304 stainless steel, tin-plated copper, outdoor rated
Low profile design
• Multiple equipment ground conductor allowance:
One 14 AWG to 6 AWG or two 10 AWG, two 12 AWG
y ' • Listed to ANSi/UL 467 by Intertek ETL
��s
• Xc'a
4
SOLAR DEPOT
800.822.4041
Contact us at: 04o.m.4700 www!wfe-jic.com
Iti
QM
($OD) 967-6917
,? ,
Advancing renewable Technology er
WEEB Washerr Electrical Equipment Bond
The WEEB line of products is designed to bond solar PV modules to mounting structures and create an
electrical path to ground. WEEBs eliminate the need for older, more costly grounding methods and greatly
reduce the amount of labor and materials used in installations. The innovative WEEB design removes the
need to run ground wire to each individual module and eliminates the need for surface preparation on
anodized aluminum components.' to install, WEEBs are placed between PV modules and mounting rails
at clamping points or at bolted connections. When anti -seize is applied and the hardware is tightened
down to the appropriate torque spec, the WEEBs' specialized teeth embed into anodized aluminum,
galvanized steel, or any electrically conductive metal to establish a gas tight electrical connection. When
used in conjunction with a WEEB Lug, the entire solar installation becomes safely and reliably grounded:
SOLAR. DEPOT
800.822.4041
W3
-iz
CUP'ERTINO
13Uildlnn _"
• Material: 304 stainless steel
• Listed to ANSI -UL 467 by Intertek ETL for use in Ca the ( 2 3 Z015
• Maximum electrical equipment ground conductor sizq;�Dg�dFvr'th
2 WEEBs contacting each module in an assembly: 6AWG k CODE COMPLIANCE
• Outdoor rated Reviewed gv
Module wattle
Mounting Fail
Contact us at. 045.24'7.4.700 www.we-fic.com
:e
Rail
FQ
Systems
Sunmodule%
Grounding of module and frame in US and Canada
Traditional Grounding Methods:
The module can be grounded by connecting hardware and
copper wire to the grounding holes using lay in lug. The lug
can be fixed;
A) Atthe module corner by using a socket head cap screw or
B) Atthe hole provided in the flange by using a screw with a
serrated washer, a washer and a nut.
The module also can be grounded to the rail utilizing the
following hardware:
C) WEEB-DPF forSolarWorad Sunfix Ground Mouht and
Sunfix Plus mounting systems..
D) WEEB-PMC for SolarWorld Sunfix Ground Mount and
Professional Solar mounting systems.
E) UGC 1 for Unirac Solar Mount mounting system.
F) Long Clawfor Panel Claw mounting system.
Q Note:
These grounding methods have been tested by Intertek
Laboratory in accordance to UL 1703 usingSolarWorld`s
modules.
Recommended components
and their
appropriate
tightening torque
for grounding in US
Canada.
and
• ",ti;...wYNviV,a�, ..(•ii4i:I,
,,.• r/�a'•�'••y
'4 X'>GD;esc�iption'.
teri• `". °a
yTlg•,M
,
.gtorgGee,�:�w:4:il'
a,:,• . ,au,;r•'
— i.a�VL. .1'1•
35 Ibf-in, 46 WG tr
Lay -In lug
Ilsco GBL-4DBT
251bf-in, 8 AWG str
20 Ibf- in,10-14AWG sol/str
Socket head cap
screw
10-24, S/8", Ss 18-8
62 Ibf-in (7.0 Nm)
Bolt
#6-32, SS
Serrated washer
M5, ss
Washer
ID 9/641-, DD 3/8, SS
38 Ibf-in (4.3 Nm)
Nut
#6-32,55
BurndyWEEB-DPF
121bf-ft(16.3•Nm)
GroundingCiip
BurndyWEEB-PMC
12 1 bf-ft (16.3 N m)
Unirac UGC -1
10 Ibf-ft (13.5 Nm)
Grounding Claw I Panel Claw Long Claw 118-20 Ibf-ft (244-271 Nm)
hardware Is 1S Ibf-ft (2o Nm). Choose the higherrequiredrequired to ue of tuetorthe he values
specified by the Installation guide for grounding and SolarWorid's module
torque requirement.
www.sclarworld.com
m "Ft
< s t
kr f
�i
Q T
C;
r
A� Z z
'C
0 , Q
Lay -in lug (Module's corner key) Lay -in lug (Module's Flange)
C���J 4i fll�jLgl t.'v jt �.11 n �rrn II, ap N) , {
r jri ppiJkl'i ji A� (ji lll'!II��1 ,�lu�f�' rii ��5
5.I,
i I � � uc 114 19�9fJ(�J
Ijlly�" � � •T��I, � r?:' ������.�}' ,�1�1!I�NJI��;Ye;�l UJ1. � !}a';1' {liar"i ti'�'JIj'j
�h .r d P, lkLf i.�{j.�y �,�9�1 IidrlrJoi�ld lil���ili(llll�l��{�f�i'4i �Igl�ilf ,J
4�0.V�;.1�11�'��P�J,{�'y.��I�i�IiIIIGflll�l�ll
WEEB—DPF WEEB—PMC
E F
iiiIrr ie�iar� —
UGG-1 Long Claw
0 Note:
1. Use general purpose anti -seize compound on fastener
threads when installing WEEBs.
2. The NEC section 690.43 states, «Exposed non-current
carrying metal parts of module frames, equipment,
and conductor enclosures shall be grounded in accor-
dance with 250.134 or 250.136(A) regardless of voltage.))
3. WEEBs are intended for SINGLE USE ONLY. Functionality
will not be guaranteed if reused.
SOLARWORLD
Weturn sunlight into power.
FE
0
N
N
The SnapNrack line of solar mounting
systems is designed to reduce total
installation costs. The system features
technical innovations proven on more
than 20OMW of solar projects to simplify
installation and reduce costs.
Flashed L Foot Simplified
SnapNrack Series 100 Flashed L Foot Kit is an innovative
solution to provide a long lasting watertight -seal over
the life of the system. The Flashed L Foot provides a
single fastener flashed to an attachment composition
shingle roof with no required cutting of shingles. The L
Foot is engineered for maximum adjustability for a clean
level installation.
• i" slotted bolt connection
• 1" spacers available for increased adjustability
• Clear or Black anodized aluminum components
(both available with black flashing)
• No Cutting of shingles
Patent Pending
Flashed L Foot in 3 Simple Steps:
1) Locate the rafter and drill the pilot hole
2) Prep and attach the base
3) Set the flashing and attach the L Foot
Place order through your SnapNrack
distributor, which can be found at
www.snapnrack.com/contact
Snag rack
Flashed L FOot K t As58rnbled ff s(�ai: of '_i!•a s=Cl@Iai: Pa
=1 r) Fh:hed i Foot h it i �it s (1" Si la:_er _•:c seoar-el; ,
Flashed L Foot Kit Assembly
HUT
L -FOOT, CLEAR
5/SGISX IIN 6OLT'NIiH .
Sn7TLOCKWASNER
--SNAPNP.ACK L-FOOTBASE
Flashed L Foot Kit Dimensions
Snag rack
(877) 732-2860 www.SnapNrack.com
0 Printed on recycled paper using soy based inks.
O 2013 by SnapNrack PV Mounting System. All rights reserved.
OUPERTINO
AR 2 3 2015
CUMPLIANCE
V ��,,, ,/ 4,0"e
n
Sunfix Ground Mount:
» Use WEER -PMC at end clamp locations to bond solar
module frames to module mounting beam.
M
FFravided
Use WEEB-DPF at mid -clamp locations on outer -beams to
z
bond solar module frames to module mounting beams.
Sunfix plus:
» Use WEEB-DPF at mid -clamp locations on outer -beams
E
to
bond solar module frames to module mounting beams.
rr
C
Professional Solar:
�-rw
» Use WEEB-PMC at mid -clamp locations on outer -beams tom
T
C
bond solar module frames to module mounting beams,
Unirac SolarMount:
» Use UGC -1 at mid -clamp and end -clamp locations
on
outer -beams to bond solar module frames to module
mounting beams.
C
Panel Claw, Polar Bear:
» This Claw is used for PV modules that are not compatible
with flange clamp style Claws, The Long Claw attaches
C
atthe module mounting holes. Please see the module
M
manufacturer's installation guide for screwtorque speci-
n �.
fications.
Fiolequanrityand rocarli
C=
Panel Claw, Polar Bear
Mgserrated
flaggenut
WEEO.DPF
Mascrratc�
SolarWorld flanBenul•
Washcr
5olarWorld
end clamp
spacer
WBT--holt
Sunfix Ground Mount Module Clamp Sunfix Ground Mount End Clamp
qhs Claw
Flange
SolarWc
mid -clan
washer
SOIarWodd
Washer
Wag -PMC SolarWor
channel
Sunfix Plus Module Clamp
Unirac solarMount
M
z
m
�° s
E
�
rr
C
Q
T
C
�
�
C
tdU
C
M
n �.
r3
C=
0a
��Ig++vu,unr rail tanytype)
Mid
Dove
sildir
Professional Solar
SolarWorld
Mg holt
WEEII-QPF
SolarWorld
plasticbolt
guide
WEER -PMC
QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping D... http://database.ul.com/cgi-bin/XYV/template/LISEXT/lFRAME/sho...
1 of 2
QIMS.E359313
Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for
Use with Photovoltaic Modules and Panels
Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use
with Photovoltaic Modules and Panels
See General information for Mounting Systems, Mouoting Devices Clamping DeviceS..and Ground Lugs for Use with Photovoltaic Modules and
Panels
SUNRUN SOUTH LLC, DBA SNAPNRACK
775 Flero Ln
Suite 200
San Luis Obispo, CA 93401 USA
Investigated
Investigated for System Fire
Cat. for Mechanical Classification
No. Bonding Loading (A, B or Q Tested in Combination With
Photovoltaic mounting system
Series Y N- UL Listed PV Modules:
50
3
E359313
REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235,
REC240, REC245, REC250, REC255, REC260, REC265, REC270, all
followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3.
Hyundai Heavy Industries Co Ltd:
HIS-MxxxMG Series - HiS-M210MG, HIS-M213MG, HIS-M215MG,
HIS-M218MG, HIS-M220MG, HIS-M223MG, HIS-M225MG,
HiS-M228MG, HIS-M230MG, HiS-M233MG, HiS-M235MG,
HIS-M238MG, HiS-M240MG, HIS-M243MG, HiS-M245MG,
HIS-M248MG, HIS-M250MG, HIS-M253MG, HIS-M255MG,
HIS-M258MG, HIS-M260MG, HIS-11263MG, HiS-M265MG,
HIS-M268MG, HiS-M270MG;
HIS-SxxxMG Series - HIS-S220MG, HIS-S223MG, HIS-S225MG,
HIS-S228MG, HIS-S230MG, HIS-S233MG, HiS-S235MG, HIS-S238MG,
HIS-S240MG, HIS-S243MG, HiS-S245MG, HIS-S248MG, HIS-S250MG,
HiS-S253MG, HiS-S255MG, HIS-S258MG, HIS-S260MG, HIS-S263MG,
HIS-S265MG, HiS-S268MG, HIS-S270MG, HiS-S273MG, HiS-S275MG;
all may be followed by the suffix BK or blank.
Renesola Jiangsu Ltd: JCxxxM-24/BB Series - JC200M-24/13b,
JC205M-24/13b, JC21014-24/13b, JC215M-24/Bb, JC220M-24/Bb,
JC225M-24/13b, JC230M-24/13b, JC235M-24/13b, JC240M-24/13b,
JC245M-24/Bb, JC250M-24/13b, JC255M-24/Bb, JC260M-24/13b,
JC26SM-24/Bb, JC270M-24/Bb.
Series Y
N -
100
Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701,
MVX-245-60-5-701, MVX-250-60-5-701, MVX-255-60-5-701,
MVX-260-60-5-701, MVX-265-60-5-701;
MVX-235-60-5-7B1, MVX-240-60-5-7B1, MVX-245-60-5-7131,
MVX-250-60-5-7B1, MVX-255-60-5-7B1, MVX-260-60-5-7B1,
m
MVX-265-60-5-7131;
OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800,
OPT -265-60-4-800, OPT -270-60-4-800, OPT -275-60-4-800;
m
c
<
' ` ''` '
C':y s
OPT -250-60-4-860, OPT -255-60-4-8130, OPT -260-60-4-860,
CD
r
. .:';e
-
OPT -265-60-4-880, OPT -270-60-4-8130, OPT -275-60-4-8130.
Q
o:.
T
C
a
Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b,
C`
<<
C
1/2/2015 8:19 AM
Z
0
QIMS.E359313 - Mounting Systems, Mounting Devices, Clamping D... http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/sho...
1 of 2
QIMS.E359313
Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for
Use with Photovoltaic Modules and Panels
Page Bottom
Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use
with Photovoltaic Modules and Panels
See General Information for Mount na Systems Mounting Devices Clamping Devices and Ground Luos for Use with Photovoltaic Modules and
Panel
SUNRUN SOUTH LLC, DBA SNAPNRACK
775 Flero Ln
Suite 200
San Luis Obispo, CA 93401 USA
E359313
Investigated
Investigated for System Fire
Cat. for Mechanical Classification
No. Bonding Loading (A, B or Q Tested in Combination With
Photovoltaic mounting system
Series I Y
350
SeriesI Y
100
z
M
c_
X m
m �
m rr
n �
C
� x
r
c
rrr
9
N
N
UL Listed PV Modules:
REC Solar AS: REC214, REC215, REC220, REC225, REC230, REC235,
REC240, REC245, REC250, REC255, REC260, REC265, REC270, all
followed by PE, PE(BLK), PE -US, PE-US(BLK), PE Q2 or PEQ3.
Hyundai Heavy Industries Co Ltd:
HIS-MxxxMG Series - HIS-M210MG, HIS-M213MG, HIS-M215MG,
HiS-M218MG, HIS-M220MG, HIS-M223MG, HIS-M225MG,
HiS-M228MG, HIS-M230MG, HiS-M233MG, HiS-M235MG,
HIS-M238MG, HIS-M240MG, HiS-M243MG, HIS-M245MG,
HiS-M248MG, HIS-M250MG, HIS-M253MG, HIS-M255MG,
HIS-M258MG, HIS-M260MG, HiS-M263MG, HiS-M265MG,
HiS-M268MG, HIS-M270MG;
HIS-SxxxMG Series - HIS-S220MG, HIS-S223MG, HIS-S225MG,
HIS-S228MG, HIS-S230MG, HIS-S233MG, HiS-S235MG, HIS-S238MG,
HIS-S240MG, HIS-S243MG, HiS-S245MG, HIS-S248MG, HIS-S250MG,
HiS-S253MG, HiS-S255MG, HIS-S258MG, HIS-S260MG, HiS-S263MG,
HiS-S265MG, HiS-S268MG, HIS-S270MG, HiS-S273MG, HIS-S275MG;
all may be followed by the suffix BK or blank.
Renesola Jiangsu Ltd: JCxxxM-24/1313 Series - JC200M-24/Bb,
JC205M-24/13b, JC210M-24/13b, JC215M-24/Bb, JC220M-24/13b,
JC225M-24/13b, JC230M-24/13b, JC235M-24/6b, JC240M-24/13b,
JC245M-24/13b, JC250M-24/Bb, JC255M-24/13b, JC260M-24/13b,
JC265M-24/Bb, 3C270M-24/Bb.
Suniva Inc - MVX-235-60-5-701, MVX-240-60-5-701,
MVX-245-60-5-701, MVX-250-60-5-701, MVX-255-60-5-701,
MVX-260-60-5-701, MVX-265-60-5-701;
MVX-235-60-5-7131, MVX-240-60-5-7131, MVX-245-60-5-7131,
MVX-250-60-5-781, MVX-255-60-5-761, MVX-260-60-5-7B1,
MVX-265-60-5-781;
OPT -250-60-4-800, OPT -255-60-4-800, OPT -260-60-4-800,
OPT -265-60-4-800, OPT -270-60-4-800, OPT -275-60-4-800;
OPT -250-60-4-8130, OPT -255-60-4-8130, OPT -260-60-4-8130,
OPT -265-60-4-8130, OPT -270-60-4-8130, OPT 275-60-4-8B0.
Yingli Energy (China) Co Ltd - YLXXXP-29b Series - YL215P-29b,
1/2/2015 8:19 AM
TECHNICAL BULLETIN
SOLARWORLD MODULE TYPES
May 19, 2014 1 Issue: 1027
Module Typing of SolarWorld Modules
SolarWorld has completed the spread of flame fire performance testing of our photovoltaic modules to classify them to the
updated UL 1703 standards. When combined with Class A mounting systems our modules meet the photovoltaic fire system
rating of Class A.
Module Types
There are up to 15 different module types classified by UL. Types are defined by their construction characteristics such as glass
thickness, EVA thickness, back sheet thickness and fire performance.
Testing Criteria
For Class A testing (the most stringent) the module is positioned to simulate mounting to a ballasted system or sloped roof
at 22 -degrees and exposed to calibrated flame and wind from a standard distance. The flame is continuously applied to the
bottom of the module for 10 minutes.
Passing Criteria
In orderto pass the spread of flame test:
M No part of the module can be blown or falloff the deck in the form of flaming or glowing brands
® No portion of the module or roof deckthat forms part of the building can fall away in the form of glowing particles
® The flame cannot spread laterally on the top surface or intermediate channel such as the space between the module
and a roof
® Flame may not spread beyond the specified distance:
TESTING CLASS
Class A
Class 8
Class C
Results
Sunmodule Plus and Pro -Series: Type 1
Sunmodule Pro -Series XL: Type 1
Sunmodule Protect: Type 3
FLAME SPREAD DISTANCE (ft)
r
73
FLAME SPREAD DISTANCE (m)
WMA
2.4
3.9
When combined with a Class Akm i' !�rstem our modules meet the photovoltaic fire system Class A requirement.
m
m:'
CD rr
TECHNICAL BULLETIN
m
ems n_ `•
C
tm
It
O
N
t-!.
N
O
N
D
1.00