B-2018-0011
SMOKE i CARBON MONOXIDE ALARMS
OWNER CERTIFICATE OF COMPLIANCE,
COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION
CUPERTINO 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255
(408) 777-3228 • FAX (408) 777-3333 • build inaCcr.cupertino.oro
PURPOSE
This affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for
compliance with 2016 CRC Section R314, R315, 2016 CBC Sections 420.6 and 907.2.11.2 where no interior access
for inspections are required.
GENERAL INFORMATION
Existing single-family and multi -family dwellings shallbe provided with Smoke Alarms and Carbon
Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds
$1000.00, CRC Section R314, R315, and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or
Carbon Monoxide Alarms be installed in the following locations:
AREA
SMOKE ALARM
CO ALAR_ M
Outside of each separate sleeping area in the immediate vicinity of the
bedrooms) - (Smoke alarms shall not be located Adfl- in 3 feet of bathroom door)
X
X
On every level of a dwelling unit including basements and habitable attics
X
X
Within each sleeping room
X
Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that
do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with
CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal.
Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated.
In existing dwelling units, alarms are permitted to be solely battery operated where -repairs or alterations do
not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crai,\71
space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for
alarms which must be connected to the building wiring.
As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been
installed in accordance with the manufacturer's instructions and in compliance with the California Building
and California Residential Codes. The alarms specified below have been tested and are operational, as of the
date signed below.
Address;
Permit No. E - 2G -- 00 /l
Specify Number of Alarms: � # Smoke Alanns: �� # Carbon_ Monoxide Detectors: I z i
I have read and aqree to comply with the terms and conditions of this statement
Owner (or Owner Agent's) Name:
/ P
Signature....... ....... I ................... .................................. Dater
ContractorName: x
Signature......�............................IIate: ..
Smoke and COform.dac revised 01/10/2017
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
Abby Ayende
01/04/18
SERVICE #: S-5849148
DATE: 12.15.2017
DRAWN BY: SR
PV 0.0
GOVERNING CODES
ALL WORK SHALL CONFORM TO THE FOLLOWING CODES
a. 2016 CA BUILDING CODE
b. 2016 CA ENERGY CODE
c. 2016 CA ELECTRICAL CODE
d. 2016 CA FIRE CODE
e. 2016 CA GREEN CODE
f. 2016 CA MECHANICAL CODE
g. 2016 CA PLUMBING CODE
h. 2016 CA RESIDENTIAL CODE
i. ANY OTHER LOCAL AMENDMENTS
SHEET INDEX:
COVER SHEET
PV 1.0 - SITE PLAN
S 1.0 - MOUNT DETAILS
EE 1.0 - ELECTRICAL DIAGRAM
EE 2.0 - ELECTRICAL NOTES
EE 3.0 - WARNING LABELS
EE 4.0 - WARNING LABEL LOCATIONS
EE 5.0 - ELEC PANEL PHOTOS
EE 5.1 - ELEC METER/STICKER PHOTOS
1800 ASHTON BLVD, LEHI, UT 84043
1.877.404.4129
CA LICENSE: B/C46/C10/C39-973756
vivint.Solar
Hoeke RESIDENCE
10645 CULBERTSON DR
CUPERTINO, CA, 95014
UTILITY ACCOUNT #: 63904657176
GENERAL STRUCTURAL NOTES:
a. THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE
ROCK-IT SYSTEM BY ECOFASTEN. THE MOUNTING FEET ARE TO BE SPACED
AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT
FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD.
b. UNLESS NOTED OTHERWISE, MOUNTING ANCHORS SHALL BE 5 16" LAG
SCREWS WITH A MINIMUM OF 2 1 2" PENETRATION INTO ROOF FRAMING.
c. THE PROPOSED PV SYSTEM ADDS 2.6 psf TO THE ROOF FRAMING SYSTEM.
d. ROOF LIVE LOAD = 20 psf TYPICAL, 0 psf UNDER NEW PV SYSTEM.
e. GROUND SNOW LOAD = 0 psf
f. WIND SPEED = 110 mph
g. EXPOSURE CATEGORY = C
COVER SHEET
JURISDICTIONAL NOTES:
GENERAL ELECTRICAL NOTES:
a. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL
MEANS DESIGNED AND LISTED FOR SUCH USE. FOR ROOF-MOUNTED
SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF
THE ROOF SURFACE.
b. ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE
CORRECTED ON INSTALLATION.
c. SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE
d. RAPID SHUTDOWN INITIATION TAKES PLACE AT THE AC DISCONNECT. UPON
LOSS OF UTILITY VOLTAGE, ARRAY CIRCUITS ARE OPENED VIA ROOFTOP.
e. SEE *E 1.0 AND *E 2.0 FOR DIAGRAMS, CALCULATIONS, SCHEDULE AND
SPECIFICATIONS.
PHOTOVOLTAIC SYSTEM SPECIFICATIONS:
SYSTEM SIZE - 5.800kW DC | 6.000kW AC
MODULE TYPE & AMOUNT - (20) JINKO SOLAR JKM290M-60B
MODULE DIMENSIONS - (L/W/H) 64.97in/ 39.06in/ 1.57in
INVERTER - (1) FRONIUS PRIMO 6.0*
*INVERTERS USED IN THIS DESIGN IS COMPLIANT WITH CEC 690.12 (RAPID SHUTDOWN). SEE MANUFACTURER DATA SHEET.
INTERCONNECTION METHOD - LOAD BREAKER
Abby Ayende
01/04/18
01/04/18
B-2018-0011
Abby Ayende
N SERVICE #: S-5849148
DATE: 12.21.2017
DRAWN BY: SR
PV 1.0
SYSTEM LEGEND
vivint.Solar
Hoeke RESIDENCE
10645 CULBERTSON DR
CUPERTINO, CA, 95014
UTILITY ACCOUNT #: 63904657176
SITE PLAN
SCALE: 1/8" = 1'-0"
M
I AC10645 CULBERTSON DR CUPERTINO,CA 95014FRONT OF HOUSE.MPPT(S):
(INV. 1)
(11) MPPT 1A
(INV.1)
(9) MPPT 2A
ROOF SECTION(S):
1 TILT - 27
AZIMUTH - 190
MATERIAL - Comp Shingle
1.877.404.4129
CA LICENSE: B/C46/C10/C39-973756
FIRE CODE OFFSET
RIDGE: 36" | RAKE: 36"
HIP/VALLEY: 18"ACEXISTING EXTERIOR MSP & UTILITY METER
#1007213219,
POINT OF INTERCONNECTION.
M
NEW PV SYSTEM AC DISCONNECT. LOCATED
WITHIN 10' OF MSP.
I
ň 6.000kW AC
PV SYSTEM SIZE:
NEW 5.800kW DC
1 NEW PV SYSTEM INVERTER: FRONIUS PRIMO 6.0.
20 NEW JINKO SOLAR JKM290M-60B
MODULES.
NEW QUATTRO RSD BOX. (MULTI)
NEW PV CONDUIT RUN.*SEE EE1.0 CONDUIT SCHEDULE
= EXTERIOR RUN = ATTIC RUN
1
Abby Ayende
01/04/18
5/16"x3/8"
HEX FLANGE BOLT
300 SERIES SS
ISOMETRIC VIEW
SIDE VIEW
5/16"x4 1/2"
SS LAG SCREW
72548(߰ )7/%6
COMP SHINGLES
METAL
FLASHING
COMP SHINGLES
SHIP LAP
METAL FLASHING
ROCK-IT SLIDE
METAL
FLASHING
COMP SHINGLES
PV 2.0
1 ROCK-IT MOUNT
NOT TO SCALE
ROCK-IT COUPLING
MID CLAMP
ROCK-IT
PEDESTAL
(1) 5/16"x4 1/2"
SS LAG SCREW
72548(߰ )7/%6
EPDM BONDED WASHER
FORMS WATERTIGHT SEAL
2
PV 2.0
SECTION VIEW
ROCK-IT SLIDE
SIDE VIEW
TOP VIEW
ISOMETRIC VIEW
ROCK-IT COUPLING
MID CLAMP
ROCK-IT COUPLING SHELF
TIE PLATE
ROCK-IT COUPLING
MID CLAMP
ROCK-IT
COUPLING SHELF
PV 2.0
2 ROCK-IT COUPLING ASSEMBLY
NOT TO SCALE
5/16"x1 1/2"
HEX FLANGE BOLT
300 SERIES SS
2 1/2" MIN
COUPLING
CLAMP + ATTACHMENT
COUPLING
CLAMP + ATTACHMENT
L=PORTRAIT
CLAMP SPACING
PERMITTED
CLAMP SPACING
MODULE
L=LANDSCAPE CLAMP SPACING
MODULE
MODULE
COUPLING
RAFTER
CLAMP RAFTER
CANTILEVER L/3 OR LESS
RAFTER
PV 2.0
5 MODULES IN PORTRAIT/LANDSCAPE
NOT TO SCALEPV 2.0
4 PV SYSTEM MOUNTING DETAIL
NOT TO SCALE
PV 2.0
3 SECTION VIEW
NOT TO SCALE
PV 2.0
6 PV ARRAY TYP. ELEVATION
NOT TO SCALE
PV MODULE, TYP. MOUNT
TO FRAMING OF EXISTING
ROOF TYPE, PARALLEL
WITH PLANE OF ROOF
1
PV 3.0
PV 2.0
7 CONDUIT MOUNTING DETAIL
NOT TO SCALE
3" MIN AND 6" MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE
CONDUITONE HOLE STEEL STRAP
CONDUIT MOUNT BRACKET
FLASHING OR TILE STRAP
1 1/2"
6" MAXIMUM
U.L. LISTING FOR ECOFASTEN: 2703
WEIGHT: 2.3 lb.
LANDSCAPE=MAX 72" (6')
PORTRAIT=MAX 48" (4')
TRUSS
2x4 AT 24 O.C.
S 1.0
MOUNTING LEGEND
vivint.Solar
MOUNT DETAILS
SCALE: NOT TO SCALE
SERVICE #: S-5849148
DATE: 12.15.2017
DRAWN BY: SR
Hoeke RESIDENCE
10645 CULBERTSON DR
CUPERTINO, CA, 95014
UTILITY ACCOUNT #: 63904657176
1.877.404.4129
CA LICENSE: B/C46/C10/C39-973756
Abby Ayende
01/04/18
Tag # Description Wire Gauge # of Conductors/Color Conduit Type Conduit Size
1 PV Wire 10 AWG 2(V+, V-) N/A-Free Air N/A-Free Air
1 Bare Copper Ground(EGC/GEC) 6 AWG 1 BARE N/A-Free Air N/A-Free Air
2 THWN - 2 12 AWG 4(2V+, 2V-) B/R EMT 3/4"
2 THWN-2 - EGC/GEC 8 AWG 1(GRN) EMT 3/4"
3 THWN - 2 12 AWG 2(1V+, 1V-) B/R EMT 3/4"
3 THWN-2 - EGC/GEC 8 AWG 1(GRN) EMT 3/4"
4 THWN - 2 8 AWG 3(1L1 1L2 1N) B/R/W EMT 3/4"
4 THWN-2 - EGC/GEC 8 AWG 1(GRN) EMT 3/4"Created: 12/15/17Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER)Hoeke Residence10645 CULBERTSON DRCUPERTINO, CA 95014Utility Account:63904657176SHEET
NUMBER:E. 15849148 CA LICENSE: 973756 (C46 & C10)INSTALLER NUMBER: 1.877.404.4129INSTALLER: VIVINT SOLAR3-Line Drawing SHEET
NAME:
Photovoltaic System
DC System Size (Watts)
AC System Size (Watts)
Total Module Count
5800
6000
20
Fronius
Primo 6.0-1 240
2
3
4
1
1
Input String 2A:
9 PV Modules
String Voc:
349.2 V
Input String 1A:
11 PV Modules
String Voc:
426.8 V
11
9
Fronius Rapid Shutdown Disconnect, Nema 4X
Existing 240V/200A Service Panel, Single
Phase, with 200A Main Disconnect
Rapid Shutdown
Disconnect, Square D
DU222RB, 240V/60A,
Unfused, NEMA3, or
equivalent
Visible/Lockable 'Knife' AC
Disconnect
4
Minimum GEC size 2
AWG copper
35A
Point of Interconnection, Load Side
705.12(D)(2)(3)(e)
200A
Abby Ayende
01/04/18
Created: 12/15/17INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129CA LICENSE: 973756 (C46 & C10)Notes Page SHEET
NUMBER:E. 25849148 Hoeke Residence10645 CULBERTSON DRCUPERTINO, CA 95014Utility Account:63904657176SHEET
NAME:
Inverter Make/Model
PV Module Rating @ STC
Module Make/Model Jinko Solar JKM290M-60B
Max. Power-Point Current (Imp) 9.02 Amps
Max. Power-Point Voltage (Vmp) 32.2 Volts
Open-Circuit Voltage (Voc) 38.8 Volts
Short-Circuit Current (Isc) 9.78 Amps
Max. Series Fuse (OCPD) 15 Amps
Nom. Max. Power at STC (Pmax) 290 Watts
Max. System Voltage 1000 VDC (UL)
Voc Temperature Coefficient -0.29 %/C
AC Output Current According to art. 690.8(B)(1) 25 Amps
Nominal AC Voltage 240 Volts
THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)
Rooftop conductor ampacities designed in compliance with art.
690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c),
310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific
temperature obtained from ASHRAE 2013 data tables.
ASHRAE 2013 -
Highest Monthly 2% D.B. Design Temp.: 29.2 °C
Lowest Min. Mean Extreme D.B.: -3 °C
Fronius Primo 6.0-1 240
CEC Efficiency 96.5 %
AC Operating Voltage 240 Volts
Cont. Max. Output Current 25 Amps
DC Max. Input Current 9.4 Amps
Short Circuit Current 584 Amps
Max. Output Fault Current 584 A/154 ms
Conductor Calculations
OCPD Calculations
Other Notes
- Wire gauge calculated from art. code 310.15(B)(16) with ambient temperature calculations from
art. 310.15(2)(a).
For "On Roof" conductors we use the 90°C column ampacity, 0.5"-3.5" off-the-roof temperature
adjustment from 310.15(B)(3)(c), and raceway fill adjustments from 310.15(B)(16).
For "Off Roof" conductors we use the 75°C column ampacity, or the 90°C column ampacity with
the relevant ambient temperature and raceway fill adjustments, whichever is less.
The rating of the conductor after adjustments MUST be greater than, or equal to, the continuous
duty uprated output current.
Calculation Example - Wire Rating (90°C) x Ambient Temperature Adjustment x Conduit Fill
Adjustment >= Continuous Duty Output Current
(On Roof, Tag 2): 12 gauge wire rated for 30 A, 30 A x 0.76 x 0.8 (4 Conductors) = 18.24 A >=
15.26 A
(On Roof, Tag 3): 12 gauge wire rated for 30 A, 30 A x 0.76 x 1 (2 Conductors) = 22.8 A >= 15.26
A
(Off Roof, Tag 4): 8 gauge wire rated for 50 A, 50 A >= 31.25 A
Breakers sized according to continuous duty output current. PV circuit nominal current based off
inverter continuous output current X (1.25[art. 210.19(A)(1)(a)]).
Inverter 1: Fronius 6-1 240 Max Output = 25 A x 1.25 [art. 210.19(A)(1)(a)]
= 31.25 A < 35 A (OCPD)
system output current w/ continuous duty = 31.25 < 35A (System OCPD)
• Designed according to, and all code citations are relevant to, the CEC 2016.
• Utility Service Provided by PGE
• No battery back-ups are tied to the designed inverter(s).
• Inverter(s) used in this design is/are compliant with 690.12 (Rapid Shutdown). See manufacturer data sheet.
• All inverters installed in California are Rule 21 Utility interactive compliant.
• Array grounding and bonding designed in compliance with 690.47(C)(3).
Abby Ayende
01/04/18
Hoeke Residence10645 CULBERTSON DRCUPERTINO, CA 95014Utility Account:63904657176Created: 12/15/17WarningLabelsPageSHEET
NUMBER:E. 3INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129CA LICENSE: 973756 (C46 & C10)SHEET
NAME:5849148 Inverter Grounded Systems Per 690.5(C)
WARNING
ELECTRICAL SHOCK HAZARD
IF A GROUND FAULT IS INDICATED,
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND ENERGIZED
Combiner Boxes, J -Boxes, Disconnects, Devices, &
Inverters In Un -Grounded Systems Per 690.35(F)
(String systems)
WARNING
ELECTRICAL SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
Conduit, Raceways, and J-Boxes (Labeled Every 10')
WARNING: PHOTOVOLTAIC POWER SOURCE
AC Disconnect and Any Load Centers (Combiner Panel)
Per 690.17(E) & 705.12
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT: 25 A
NOM. OPERATING AC VOLTAGE: 240 V
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON
BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
Inverter Output Connection (Solar Breaker) at
Main Service Panel Per 705.12
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
Main Service Panel Signage
(Installed on the Face of the Service Meter)
Per 690.54, 690.56(B), & 705.10
Note: Roofline placard not needed unless PV disconnect is not at the
same location as the main service
CAUTION: SOLAR ELECTRICAL SYSTEM CONNECTED
CAUTION:
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNETS LOCATED AS
SHOWN
AT:
METER AND MAIN SERVICE
AC DISCONNECT
DC DISCONNECT
INVERTER
WARNING: DUAL POWER SOURCE
SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM
RATED AC OUTPUT CURRENT: 25 A
DC Disconnect Per 690.17
PHOTOVOLTAIC DC DISCONNECT
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON
BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
DC Disconnect Per 690.53
PHOTOVOLTAIC POWER SOURCE DC DISCONNECT
RATED MAXIMUM POWER POINT CURRENT (IMP) 9.02 A
RATED MAXIMUM POWER POINT VOLTAGE (VMP) 354.2 V
MAXIMUM SYSTEM VOLTAGE (VOC) 461.46 V
SHORT CIRCUIT CURRENT (ISC) 12.225 A
PHOTOVOLTAIC POWER SOURCE DC DISCONNECT
RATED MAXIMUM POWER POINT CURRENT (IMP) 9.02 A
RATED MAXIMUM POWER POINT VOLTAGE (VMP) 289.8 V
MAXIMUM SYSTEM VOLTAGE (VOC) 377.56 V
SHORT CIRCUIT CURRENT (ISC) 12.225 A
Rapid Shutdown Per 690.56(C)
PHOTOVOLTAIC SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO
SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED.
ALL PLACARDS SHALL BE WEATHER-RESISTANT, PERMANENTLY ETCHED PLACARDS. HANDWRITTEN SIGNS WILL NOTE BE ACCEPTABLE.
RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM
Rapid Shutdown Disconnect Per 690.12(5) Installed On AC Disconnect and
Rooftop Disconnects
Abby Ayende
01/04/18
Hoeke Residence10645 CULBERTSON DRCUPERTINO, CA 95014Utility Account:63904657176Created: 12/15/17WarningLabelsPageSHEET
NUMBER:E. 4INSTALLER: VIVINT SOLARINSTALLER NUMBER: 1.877.404.4129CA LICENSE: 973756 (C46 & C10)5849148 SHEET
NAME:
DC
DISCONNECT
INSIDE
M M
5
12
14
5
11 14
8 12
3 9 5
6
3 5
6
3 5 5
6
3 5
10
4
2
1 5
10
7
4 13
1 2
ROOFTOP ARRAY
EVERY 10' AND
WITHIN 1' OF
ELBOWS
RAPID
SHUTDOWN
DISCONNECT
SOLAR INVERTERS
(MAY BE ON ROOFTOP
INTEGRATED WITH
ARRAY)
COMBINER PANEL
(WHEN USED)
VISIBLE/LOCKABLE
A/C DISCONNECT
(WHERE REQUIRED)
VIVINT SOLAR METER
(WHERE REQUIRED)
VISIBLE/LOCKABLE
A/C DISCONNECT
INSIDE PANEL
SUB PANEL
(WHEN REQUIRED)
MAIN SERVICE
DISCONNECT PANEL
IF APPLICABLE
ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY
SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO SMALLER THAN 3/8" WHITE ARIAL FONT
TEXT, AND HAVE A RED BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED.
ALL PLACARDS SHALL BE WEATHER-RESISTANT, PERMANENTLY ETCHED PLACARDS.
HANDWRITTEN SIGNS WILL NOTE BE ACCEPTABLE.
THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES,
RACE-WAYS, CABLE ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO
AVOID CUTTING THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), WITHIN 1 FT (305MM) OF
TURNS OR BENDS AND WITHIN 1 FT (305 MM), ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR
BARRIERS
TYPICAL SOLAR GENERATION INSTALLATION
(NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION)
1 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED
Property of Vivint Solar
2
MAIN BREAKER DE-RATED TO *** DUE TO SOLAR
CIRCUITS
MAX OF ***AMPS PV SOURCE ALLOWED
DO NOT INCREASE MAIN BREAKER RATING
Property of Vivint Solar
3 WARNING
ELECTRICALSHOCK HAZARD
DO NOT TOUCH TERMINALS. TERMINALS ON BOTH
THE LINE AND LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
Property of Vivint Solar
4 WARNING: DUAL POWER SOURCE
SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM
RATED AC OUTPUT CURRENT: *** A
NOM. OPERATING AC VOLTAGE: *** V
Property of Vivint Solar
5 WARNING: PHOTOVOLTAIC POWER SOURCE
Property of Vivint Solar
6
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT: *** A
NOM. OPERATING AC VOLTAGE: *** V
Property of Vivint Solar
7 PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID
SHUTDOWN
Property of Vivint Solar
8 PHOTOVOLTAIC DC DISCONNECT
Property of Vivint Solar
9 WARNING
ELECTRICALSHOCK HAZARD
IF A GROUND FAULT IS INDICATED,
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND ENERGIZED
Property of Vivint Solar
10 WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS OVERCURRENT DEVICE
Property of Vivint Solar
11 PHOTOVOLTAIC POWER SOURCE DC DISCONNECT
RATED MAXIMUM POWER POINT CURRENT (IMP) *** A
RATED MAXIMUM POWER POINT VOLTAGE (VMP) ***V
MAXIMUM SYSTEM VOLTAGE (VOC) *** V
SHORT CIRCUIT CURRENT (ISC) ***A
Property of Vivint Solar
12 WARNING
ELECTRICALSHOCK HAZARD
THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE ENERGIZED
Property of Vivint Solar
13 SITE PLAN PLACARD SHOWING ADDITIONAL POWER
SOURCE AND DISCONNECT LOCATIONS. PLACARD
SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL
PANEL (only when necessary)
Property of Vivint Solar
14 PV rapid shutdown disconnect
placard indicated on E.3
*** - value calculated for each
account, for specific value see the
previous warning label page
Abby Ayende
01/04/18
EE 5.0
NOTES
vivint.Solar
SERVICE #: S-5849148
DATE: 12.15.2017
DRAWN BY: SR
Hoeke RESIDENCE
10645 CULBERTSON DR
CUPERTINO, CA, 95014
UTILITY ACCOUNT #: 63904657176
1.877.404.4129
CA LICENSE: B/C46/C10/C39-973756
Abby Ayende
01/04/18
EE 5.1
NOTES
vivint.Solar
SERVICE #: S-5849148
DATE: 12.15.2017
DRAWN BY: SR
Hoeke RESIDENCE
10645 CULBERTSON DR
CUPERTINO, CA, 95014
UTILITY ACCOUNT #: 63904657176
1.877.404.4129
CA LICENSE: B/C46/C10/C39-973756
Abby Ayende
01/04/18