Loading...
B-2018-0145SEAN HATCH 01/22/18 01/22/18 B-2018-0145 Abby Ayende SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SEAN HATCH 01/22/18 SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates consistent, even module spacing • UL 2703 Listed integrated grounding Flexible Design • Addresses nearly all sloped residential roofs • Design in landscape and portrait with up to 8ʼ rail span • Pre-drilled rails and rail splice • Rails enable easy obstacle management Customer-Preferred Aesthetics • #1 module and #1 mounting aesthetics • Best-in-class system aesthetics • Premium, low-profile design • Black anodized components • Hidden mid clamps and new capped, flush end clamps Part of Superior System • Built for use with SunPower DC and AC modules • Best-in-class system reliability and aesthetics • New optional rooftop transition flashing, rail- mounted J-box, and wire management rail clips • Combine with SunPower modules and SunPower EnergyLink® monitoring app sunpower.com Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system-level approach amplifies the aesthetic and installation benefits—for homeowners and for installers. Datasheet SEAN HATCH 01/22/18 SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Mid Clamp Black oxide stainless steel 300 series 63 g (2.2 oz) End Clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless steel (A2-70 bolt; tin-plated copper lug)106.5 g/m (3.75 oz) Roof Attachment Hardware Supported by Design Tool Application • Composition Shingle Rafter Attachment • Composition Shingle Roof Decking Attachment • Curved and Flat Tile Roof Attachment • Universal interface for other roof attachments InvisiMount Operating Conditions Temperature −40° C to 90° C (−40° F to 194° F) Max. Load (LRFD) • 3000 Pa uplift • 6000 Pa downforce Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation. InvisiMount Warranties And Certifications Warranties • 25-year product warranty • 5-year finish warranty Certifications • UL 2703 Listed • Class A Fire Rated © 2017 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. InvisiMount Components Module¹ / Mid Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly (for DC systems only) Module¹ / End Clamp and Rail sunpower.com 509506 RevE ² SunPower recommends that all Equinox™, InvisiMount™, and AC module systems always be designed using the SunPower Design Tool. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed Professional Engineer (PE) must then stamp all calculations. Should you have any questions please contact SunPower Technical Support at 1-800-SUNPOWER (1-800-786-7693). InvisiMount Component LRFD Capacities² Mid Clamp Uplift 664 lbf Shear 540 lbf End Clamp Uplift 899 lbf Shear 220 lbf Rail Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft Rail Splice Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft L-foot Uplift 1000 lbf Shear 390 lbf Datasheet ¹ Module frame that is compatible with the InvisiMount system required for hardware interoperability. SEAN HATCH 01/22/18 Optimize System and Installation Efficiency SunPower® AC modules, which include a factory-integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module-level DC-to-AC power conversion. Designed specifically for use with SunPower InvisiMount™ and the SunPower Monitoring System, SunPower AC modules enable rapid installation, best- in-class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty in the industry. Grid Support Utility-Interactive Smart Inverter SunPower’s new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule 21 Phase 1 requirements, and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoring hardware. sunpower.com Design-Driven Advantages ⋅ #1 module aesthetics and efficiency 1 ⋅ Unmatched module reliability2 ⋅ No electrolytic capacitors ⋅ 25-year Combined Power and Product Warranty ⋅ California Rule 21 Phase 1 compliant Maximize Value for Roof ⋅ Size system for roof, not string inverter ⋅ Optimize performance of each module Expand Deployment Options ⋅ Complex roofs and partial shading ⋅ Small systems ⋅ System expandability Simplify & Speed Installation ⋅ Factory-integrated microinverter ⋅ Robust, double-locking AC connectors ⋅ Design flexibility offsite and onsite ⋅ No DC string sizing process ⋅ Fewer installation steps than competing systems ⋅ Intuitive commissioning Component of Complete System ⋅ Built for use with SunPower® InvisiMount™ and the SunPower Monitoring System (PVS5x) ⋅ Superior system reliability and aesthetics SunPower® X22-360-D-AC | Residential AC Module Series Datasheet SEAN HATCH 01/22/18 ¹Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," Fraunhofer CSE, Feb 2013. Five out of the top eight largest manufacturers were tested. Campeau, Z. et al. "SunPower Module Degradation Rate," SunPower white paper, Feb 2013. See www.sunpower.com/facts for details. 3Factory set to 1547a-2014 default settings. CA Rule 21 default settings profile set during commissioning. See the Equinox Installation Guide #518101 for more information. 4Standard Test Conditions (1000 W/m² irradiance, AM 1.5, 25° C). NREL calibration standard: SOMS current, LACCS FF and voltage. All DC voltage is fully contained within the module. 5Based on average of measured power values during production. Warranties and Certifications Warranties ⋅ 25-year limited power warranty ⋅ 25-year limited product warranty Certifications UL listed to UL 1741 SA ⋅ SRDs: IEEE 1547-2003, IEEE 1547a-2014, CA Rule 21 Phase 1 ⋅ PV Rapid Shutdown Equipment ⋅ Equipment Grounding ⋅ UL 6703, UL 9703 Connectors and cables (load break disconnection) ⋅ UL 1741 AC Module (Type 2 fire rating) Enables installation in accordance with: ⋅ NEC 690.6 ⋅ NEC 690.12 Rapid Shutdown (inside and outside the array) ⋅ NEC 690.15 AC Connectors, 690.33(A) – (E)(1) FCC and ICES-003 Class B When used with InvisiMount racking (UL 2703): ⋅ Integrated grounding and bonding ⋅ Class A fire rated PID Test Potential-induced degradation free Please read the safety and installation instructions for details. ©May 2017 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, MAXEON and InvisiMount are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. Specifications included in this datasheet are subject to change without notice. See www.sunpower.com/facts for more reference information. For more details, see extended datasheet: www.sunpower.com/datasheets. SunPower® X22-360-D-AC | Residential AC Module Series DC Power Data SPR-X22-360-D-AC Nominal Power4 (Pnom) 360 W Power Tolerance +5/−0% Avg. Panel Efficiency5 22.2% Temp. Coef. (Power) −0.29%/° C Shade Tolerance • Three bypass diodes • Integrated module-level maximum power point tracking Tested Operating Conditions Operating Temp. −40° F to +185° F (−40° C to +85° C) Max. Ambient Temp. 122° F (50° C) Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m² front & back Snow: 1 25 psf, 6000 Pa, 611 kg/m² front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Mechanical Data Solar Cells 96 Monocrystalline Maxeon Gen III Front Glass High-transmission tempered glass with anti- reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA rating) Weight 45.5 lbs (20.6 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) 518986 RevB AC Electrical Data3 SRD Profile IEEE 1547a -2014 3 (default settings) min. / nom. / max. CA Rule 21 3 min. / nom. / max. Frequency (Hz) 59.5 / 60.0 / 60.5 58.5 / 60.0 / 60.5 Power Factor 0.99 / 1.00 / 1.00 0.85 lead. / 1.00 / 0.85 lag. Reactive Power ±169 Var Volt-VAr Voltage @240 V @208 V 211.2 / 240 / 264 V 183 / 208 / 228.8 V Max. Current @240 V @208 V 1.33 A 1.54 A DC/AC CEC Conversion Efficiency @240 V @208 V 96.0% 95.5% Max. Units Per 20 A Branch Circuit @240 V @208 V 12 (single phase) 10 (two pole) wye Power 320 W, 320 VA No active phase balancing for 3 phase installations SEAN HATCH 01/22/18