Loading...
10301 Menhart Approved Plans.pdf2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com A-00.01 COVER SHEET THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: 10301 MENHART LN. C UPERTINO , C A LOCAL TABLES / NOTES: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S ABV. Above A/C Air Conditioner A.D. Access Door ADD. Addition A.F.F. Above Finished Floor A.F.G. Above Finished Grade B.L. Building Line BLDG. Building B.O. Bottom of BTM. Bottom CABT. Cabinet C.D. Construction document C.L. Center Line CL. Closet CLG. Ceiling C.O. Clean Out CONC. Concrete D.S. Down spout D/W Dishwasher DBL. Double DEMO. Demolition DIA. Diameter DR. Door ELEV. Elevation EXIST. Existing EXT. Exterior ABBREVIATIONS: SHEET TITLE: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMSDESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMSDESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMSDESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. DESIGN A-00.01: COVER SHEET TO: BOUNDARY AND TOPOGRAPHIC MAP A-01.01: PROPOSED SITE PLAN RA-01.01: EXISTING FLOOR PLAN A-01.02: PROPOSED FLOOR PLANS A-02.01: PROPOSED ELEVATIONS A-02.02: PROPOSED ELEVATIONS A-03.01: PROPOSED SECTION & STREETSCAPE ELEVATION A-06.01: FLOOR AREA DIAGRAMS and SCHEDULES A-07.01: CONCEPTUAL LANDSCAPE OWNER: ROBERT (408)221-7544 10301 MENHART LN.,CUPERTINO,CA 95014 DESIGNER: AMS Design (415) 254-1606 2275 S. BASCOM AVE, CAMPBELL,CA 95008 SUITE 1406 AZADEH@AMSDESIGNLLP.COM STRUCTURAL: AMS Design (415) 254 -2634 2275 S. BASCOM AVE, CAMPBELL,CA 95008 SUITE 1406 ARMIN@AMSDESIGNLLP.COM T24 & ENERGY: - - - - - - - - - - - - SOIL ENGINEER: - - - - - - - - - - - - VICINITY MAP: LOT COVERAGE: 1st FLOOR BLDG AREA (1021+445) SQF COVERED AREA 110+280 SQF FIRST FLOOR ROOF EAVE 202.5 TOTAL % 2058.5/5115 = 40.2% 375-15-033 NEW CONSTRUCTION 10301 MENHART LN., CUPERTINO,CA 95014 R - 1-5 R - 3 / U V - B TWO (2) STORY SPRINKLERED LOW DENSITY(1-6 DU/Ac.) CALIFORNIA RESIDENTIAL CALIFORNIA BUILDING CALIFORNIA MECHANICAL CALIFORNIA PLUMBING CALIFORNIA ELECTRICAL CALIFORNIA ENERGY: CALIFORNIA FIRE: CALIFORNIA GREEN BUILDING: ANY OTHER APPLICABLE LOCAL AND STATE LAWS AND REGULATIONS. A. B. C. D. E. F. G. H. I. ASSESSOR'S PARCEL NUMBER: PROJECT TYPE: PROJECT LOCATION: ZONING: OCCUPANCY GROUP: CONSTRUCTION TYPE: NUMBER OF FLOORS: FIRE PROTECTION: LAND USE: 2016 EDITION 2016 EDITION 2016 EDITION 2016 EDITION 2016 EDITION 2016 EDITION 2016 EDITION 2016 EDITION TOTAL "E" BUILDING TO BE REMOVED: 1955 SQF "N" 1ST FLOOR LIVING AREA: 1021 SQF "N" 2nd FLOOR LIVING AREA: 823 SQF "N" TOTAL LIVING: 1844 SQF "N" GARAGE: 445 SQF "N" TOTAL BUILDING: 2289 SQF "N" FRONT PORCH: 110 SQG "N" REAR PORCH: 280 SQF 2ND FLOOR BALCONY: 55 SQF LOT AREA: 5115 SQF PROPERTY LOCATION / NTS2ND FLOOR TO 1ST FLOOR RATIO=(823/(1021+445))X100=56% NEW 2 STORY CUSTOME HOME 2889 SQ BUILDING AREA INCLUDING 4 BEDS, 3.5 BATH, 1 LAUNDRY AND 2 CAR GARAGE AREA CALCULATION: PROJECT DATA: "N" FLOOR AREA RATIO (FAR) = (2289/5115)X100=44.7% DRAWING INDEX:CODE EDITIONS: SCOPE OF WORK: PROJECT CONTACT: FDN. Foundation FLR. Floor FURN. Furnace G.C. General Contractor G.F.C.I. Ground Fault Circuit Interrupt GYP. Gypsum H.B. Hose bib HGT. Height HR. Hour H.R. Handrail HTR. Heater H.V.A.C. Heating, Venting and Air Conditioning INSUL. Insulation INT. Interior LAM. Laminate LAV. Lavatory MAX. Maximum MED. Medium MIN. Minimum MTL. Metal (steel) MUL. Mullion N.T.S. Not to scale N.F.C. Not for construction O.C. On center O.H. Overhead OPNG. Opening GENERAL NOTES: A- AN AUTOMATIC RESIDENTIAL FIRE SPRINKLERS SYSTEM SHALL BE INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW ONE- AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE- AND TWO-FAMILY DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA TO MORE THAN 3,600 SQUARE FEET PER SEC R313.2.1. EXCEPTION: A ONE- TIME ADDITION TO AN EXISTING BUILDING THAT DOES NOT TOTAL MORE THAN 1,000 SQUARE FEET OF BUILDING AREA. NOTE: THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. SECTION R313.2 AS ADOPTED BY CUPMC. B- POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT, AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER- BASED FIRE PROTECTION SYSTEMS, AND/ OR FIRE SUPPRESSION WATER SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF RECORD. FINAL APPROVAL OF THE REQUIREMENTS OF THE WATER PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND SAFETY CODE 13114.7. C- APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED OMN ALL NEW AND EXISTING BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. PER CFC SEC. 505 D- ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF CFC CHAPTER 14 AND SANTA CLARA COUNTY'S FIRE DEPARTMENT'S STANDARD DETAIL AND SPECIFICATION SI-7. E- PHOTOELECTRIC SMOKE DETECTORS SHALL BE PROVIDED AT BOTH THE TOP AND BOTTOM OF THE STAIRCASE. F- PHOTOELECTRIC SMOKE ALARMS SHALL BE PROVIDED IN AREAS LEADING TO SLEEPING ROOMS AND ON EVERY LEVEL. SMOKE ALARMS WITHIN SLEEPING ROOMS SHALL BE DUAL SENSOR PHOTOELECTRIC/IONIZATION. G- SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED PER RESIDENTIAL CODE. H- A NFPA 13-D FIRE SPRINKLER SYSTEM SHALL BE INSTALLED UNDER SEPERATE PERMIT. I- A SEPARATE PERMIT FOR THE SPRINKLER SYSTEM SHALL BE APPLIED FOR WITH THE SUNNYVALE BUREAU OF FIRE PREVENTION. FIRE NOTES: PLT. Plate P.L. Property line PLYWD. Plywood PWR. Power R.O. Rough Opening R.O.W. Right of way REFG. Refrigerator REF. Reference REV. Revision RMV. Remove S.C. Self-Closing SCHED. Schedule S.D. Smoke detector SECT. Section SHT. Sheet T.O.C. Top of curb T.O.F. Top of footing TH. Threshold TYP. Typical UNF. Unfinished W.C. Toilet (water closet) WCT. Wainscot W.H. Water Heater W.I. Wrought Iron W.I.C. Walk In Closet YD. Yard 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM FIRST FLOOR ROOF EAVE=135X1.5=202.5 A- APPROVAL OF THESE PLANS DOES NOT RELEASE THE OWNER AND/OR CONTRACTOR OF THE RESPONSIBILITY FOR THE CORRECTIONS OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF DURING THE COURSE OF CONSTRUCTION IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION OF/ OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR THESE IMPROVEMENT PLANS ,THE CITY ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE SUCH COMPLETED , AT THE SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR. B- CONTACT PUBLIC WORKS,(408)777-3104 , FOR INSPECTION OF GRADING,STORM DRAINAGE, AND PUBLIC IMPROVEMENTS. C- ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. D- CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND ENSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. E- CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. F- UTILIZE BEST MANAGEMENT PRACTICES (BMP's) AS REQUIRED BY THE STATE WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS THE SOIL. G- A WORK SCHEDULE OF GRADING AND ORISON & SEDIMENT CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY AUGUST 15. NO HILLSIDE GRADING SHALL BE PERFORMED BETWEEN OCTOBER 1 TO APRIL 15. H- ALL NEW ELECTRICAL SERVICE (POWER,PHONE,AND/OR CABLE) SHALL BE UNDERGROUNDED. I- TO INITIATE RELEASE OF BONDS,CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. J- A LICENSED LAND SURVEYOR OR AUTHORIZED CIVIL ENGINEER WILL PREPARE AND SUBMIT,TO THE PUBLIC WORKS DEPT,AN ELEVATION CERTIFICATE FOR THE NEW STRUCTURE/ADDITION. K- TO INITIAL RELEASE OF BONDS, CONTACT THE PUBLIC WORKED INSPECTOR FOR FINAL INSPECTION. L- ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED AREAS. M- PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT. PUBLIC WORKS NOTES: A- THE PROPERTY OWNER SHALL RECORD A COVENANT ON THE PROPERTY FOR THE NEW TREES/SHRUBS PLANTED FOR PURPOSE OF REQUIRED REPLACEMENT TREES, PRIVACY PROTECTION, AND REQUIRED FRONT YARD TREE. B- FOLLOWING COMPLETION OF CONSTRUCTION, AN AFFIDAVIT FROM AN ISA-CERTIFIED ARBORIST SHALL BE PROVIDED CONFIRMING THAT THE NEW TREES HAVE BEEN PLANTED PROPERTY AND ACCORDING TO PLAN. C- A PLANNING DIVISION INSPECTION IS REQUIRED TO VERIFY EXTERIOR MATERIALS/FINISHES, TREES, LANDSCAPING, AND SITE WORK. D- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL CONDUCT A LANDSCAPE INSTALLATION AUDIT AFTER THE LANDSCAPING AND IRRIGATION SYSTEM HAVE BEEN INSTALLED PER CHAPTER 14.15(LANDSCAPE ORDINANCE).THE FINDINGS OF THE ASSESSMENT SHALL BE CONSOLIDATED INTO A LANDSCAPE INSTALLATION REPORT PROVIDED TO THE PLANNING DIVISION. E- THE PROPERTY OWNER SHALL SIGN A LANDSCAPE MAINTANCE AGREEMENT PER CHAPTER 14.15(LANDSCAPE ORDINANCE), PREPARED BY THE CITY,AND RECORD IT WITH SANTA CLARA CO. RECORD'S OFFICE. THE PROPERTY OWNER SHALL CONTACT THE PLANNING DIVISION IN ADVANCE OF THE FINAL TO PREPARE THE AGREEMENT. F- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL PROVIDE A LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE PER CHAPTER 14.15(LANDSCAPE ORDINANCE) TO THE PLANNING DIVISION. REQ. PRIOR TO FINAL OCCUPANCY: Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano PROPOSED SITE PLAN SC : 1/8" = 1'-0" 1BLDG 1st FLOOR FOOTPRINT LINE 2nd FLOOR PROPERTY LINE BLDG 2nd FLOOR FOOTPRINT LINE LEGEND: 5'-2"17'-0"15'-1" 15'-0" 16'-9" 15'-0"9'-3"18'-0"25'-6" 5'-1"25'-6"26'-3"25'-0"26'-1"15'-5" 15'-7"19'-0" 5'-0" 5'-8"33'-4"24'-3"FRO NT PO RC HFRO NT PO RC H101.16' 105.00'57.00 ' 43 .05' Balcony Sky L. Sky L. FRONT YARD:43.05'X20'= 860 SQF PAVING AREA: DRIVE WAY(360)+ WALKWAY(70)/860=50%(860) FRONT YARD PAVING SURFACE AREA: DRIVE W AY PAVERS PERVIO US M ATERIAL LO W IM PAC T DEVELO PM ENT"N" 6' HEIG HT W O O DEN FENC E20' FRO NT SETBAC K "N " 6' HEIG HT W O O DEN FENC E "N " 6' HEIG HT W O O DEN FENC EFRO NT PO RC H REAR PO RC H 2ND Floor 2ND Floor 2ND Floor2ND Floor2ND Floor2ND Floor 4 : 124 : 12 4 : 124 : 12M ENHART LN. NEW TREE C RAPE M YRTLE 24 INC H BO X 6 FT HEIG HT"E" 4" PEAC H TREE to be rem oved 2ND Floor 2ND Floor1ST Floor1ST Floor1ST Floor1ST Floor 2ND Floor 1ST Floor 1ST Floor1/8 INCH = 1 FEET 0 2 4 6 8 10 20 30 GRAPHIC SCALE : 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com SITE PLAN 1/8" = 1' A-01.01 THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE NORTH AMS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM 1. CONTACT PUBLIC WORKS, FOR DRAINAGE AND FINAL GRADE INSPECTION, WHICH INCLUDES DRAIN LINES AND ROOF DRAINS/DOWN SPOUTS. 2. ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. 3. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. 4. THE CONTRACTOR SHALL REVIEW STD. DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. 5. UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS SOIL. 6. ALL NEW ELECTRICAL SERVICE (POWER, PHONE, AND OR CABLE) SHALL BE UNDER GROUND. 7. TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. 8. ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPE AREAS. 9. PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT. 10. PROVIDE MIN. 5% GRADE SLOPE AWAY FROM FOUNDATION FOR A MIN. DISTANCE OF 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE WALL. WITH EXCEPTION: a. IF BUILDING SITE DOES NOT ALLOW 10 FEET OF SLOPE, INDICATE THE INSTALLATION OF DRAINS OR SWALES TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. b. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION SHALL BE SLOPED A MIN 2% AWAY FROM THE BUILDING. 11. (E) DRAINAGE SHALL REMAIN THROUGHOUT CONSTRUCTION. GRADING and DEMO NOTES: 1. A PLOT PLAN SHALL BE PREPARED DESCRIBING THE RELATIONSHIP OF PROPOSED GRADING AND UTILITY TRENCHING TO THE TREES DESIGNATED FOR PRESERVATION. CONSTRUCTION AND GRADING SHOULD NOT SIGNIFICANTLY RAISE OR LOWER THE GROUND LEVEL BENEATH TREE DRIP LINES. IF THE GROUND LEVEL IS PROPOSED FOR MODIFICATION BENEATH THE DRIP LINE, THE ARCHITECT/ARBORIST SHALL ADDRESS AND MITIGATE THE IMPACT TO THE TREE(S). 2. ALL TREES TO BE PRESERVED ON THE PROPERTY AND ALL TREES ADJACENT TO THE PROPERTY SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION OPERATIONS BY CONSTRUCTING A FOUR-FOOT-HIGH FENCE AROUND THE DRIP LINE, AND ARMOR AS NEEDED. THE EXTENT OF FENCING AND ARMORING SHALL BE DETERMINED BY THE LANDSCAPE ARCHITECT. THE TREE PROTECTION SHALL BE PLACED BEFORE ANY EXCAVATION OR GRADING IS BEGUN AND SHALL BE MAINTAINED IN REPAIR FOR THE DURATION OF THE CONSTRUCTION WORK. 3. NO CONSTRUCTION OPERATIONS SHALL BE CARRIED ON WITHIN THE DRIP LINE AREA OF ANY TREE DESIGNATED TO BE SAVED EXCEPT AS IS AUTHORIZED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT. 4. IF THE TRENCHING IS REQUIRED TO PENETRATE THE PROTECTION BARRIER FOR THE TREE, THE SECTION OF TRENCH IN THE DRIP LINE SHALL BE HAND DUG SO AS TO PRECLUDE THE CUTTING OF ROOTS. PRIOR TO INITIATING ANY TRENCHING WITHIN THE BARRIER APPROVAL BY STAFF WITH CONSULTATION OF AN ARBORIST SHALL BE COMPLETED. 5. TREES WHICH REQUIRE ANY DEGREE OF FILL AROUND THE NATURAL GRADE SHALL BE GUARDED BY RECOGNIZED STANDARDS OF TREE PROTECTION AND DESIGN OF TREE WELLS. 6. THE AREA UNDER THE DRIP LINE OF THE TREE SHALL BE KEPT CLEAN. NO CONSTRUCTION MATERIALS NOR CHEMICAL SOLVENTS SHALL BE STORED OR DUMPED UNDER A TREE. 7. FIRES FOR ANY REASON SHALL NOT BE MADE WITHIN FIFTY FEET OF ANY TREE SELECTED TO REMAIN AND SHALL BE LIMITED IN SIZE AND KEPT UNDER CONSTANT SURVEILLANCE. 8. THE GENERAL CONTRACTOR SHALL USE A TREE SERVICE LICENSEE, AS DEFINED BY CALIFORNIA BUSINESS AND PROFESSIONAL CODE, TO PRUNE AND CUT OFF THE BRANCHES THAT MUST BE REMOVED DURING THE LANDSCAPE ARCHITECT/ARBORIST WITH APPROVAL OF STAFF. 9. ANY DAMAGE TO EXISTING TREE CROWNS OR ROOT SYSTEMS SHALL BE REPAIRED IMMEDIATELY BY AN APPROVED TREE SURGEON. 10. NO STORAGE OF CONSTRUCTION MATERIALS OR PARKING SHALL BE PERMITTED WITHIN THE DRIP LINE AREA OF ANY TREE DESIGNATED TO BE SAVED. 11. TREE PROTECTION REGULATIONS SHALL BE POSTED ON PROTECTIVE FENCING AROUND TREES TO BE PROTECTED. TREE PROTECTION NOTES: 1. DIRECT ROOF RUNOFF ONTO VEGETATED AREAS. 2. DIRECT RUNOFF FROM SIDEWALK,WALKWAYS,AND/OR PATIOS ONTO VEGETATED AREAS. 3. CONSTRUCT DRIVEWAY WITH PERMEABLE SURFACE. GREEN BUILDING MEASURE NOTES: Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano 1 SC : 1/4" = 1'-0" PROPOSED 1ST FLOOR PLAN 2 SC : 1/4" = 1'-0" PROPOSED 2nd FLOOR PLAN UP UP Sky L. 30"x24" Sky L. 30"x24"D/WREF.2868105010502650 3080 16080 30685060 50601046104630462468 36801680 5060 10080 2480 28683680 28805050 15'-0" X 28'-3" 5'-0" X 5'-0" 20'-0" X 20'-0" 5'-0" X 8'-1" 3'-4" X 3'-3" 15'-0" X 14'-1" 6'-3" X 3'-3" 11'-1" X 10'-8"5'-1"20'-0"20'-0" 28'-7"10'-7"24'-7" 3'-11"13'-0"41'-10"28'-11"12'-11" 1'-6" 4'-4"6'-0" 9'-0" 6'-5" 3'-2" 1'-1"5'-0"2'-0" 5'-0" 1'-4" 41'-10"20'-8" 2'-11" 3'-8" 11'-3" 3'-4"0'-8"2'-8"0'-4"1'-8" 5'-0" 1'-4" 2'-8"0'-7"3'-4"16'-11" 3'-0"0'-9" 7'-7" 36'-0" 11'-6" 24'-6" 10'-0" 4'-7" 0'-10"5'-11"4'-9" 36'-0" 16'-5" 19'-7" 2'-3" 5'-0" 2'-0" 1'-6"0'-4"3'-6" 1'-10"1'-3"16'-0" 2'-4" 3'-6" 4'-1"3'-6" 8'-0"28'-3"18'-5"13'-6" 14'-9"9'-4"BEDRO O M SLO PETA NKLESS W ATER HEATER 6' A BO VE A G ARA G E FLO O R BELO W F.F. BELO W F.F. 18" 12"W A. DR. G ARAG E KITC HEN & FAM ILY A-03.01 A-03.01 A A LAUNDRY UTILITYA-03.01LIVING BATH PO W DER BBA-03.0120302030 24805050 2880 5050 2480 50802030 20302880 2280 288020302030 2030 4680 46804680 28802880 2030 2030 4080 4080 3030 3030 30305650 20302030 2030 5'-4" X 2'-4" 13'-9" X 11'-6" 8'-2" X 3'-3" 10'-0" X 5'-0" 10'-2" X 2'-0" 10'-0" X 10'-0" 3'-0" X 1'-6" 8'-0" X 5'-0" 9'-11" X 10'-0" 6'-2" X 2'-4" 10'-2" X 5'-0" 2'-2" X 9'-2"49'-0"10'-8"2'-9" 15'-8" 9'-10" 10'-1" 2'-4"3'-0" 1'-0"3'-0"1'-0"3'-0"2'-4" 0'-10"2'-0"5'-0" 2'-0" 0'-10"49'-0"11'-11" 2'-4" 5'-5" 6'-10" 5'-4" 2'-9" 10'-8" 3'-9"0'-10"2'-0" 4'-11" 2'-0"0'-11"0'-5"2'-7"0'-9"1'-10" 2'-0" 1'-6"1'-10" 2'-0" 1'-7" 1'-0"2'-0" 6'-2" 2'-0"0'-9"2'-8" 21'-0" 10'-4" 10'-8" 0'-6" 2'-8"1'-1"5'-0"1'-1"2'-10"5'-0" 2'-10" 1'-3" 1'-0" 4'-4" 17'-1" 2'-8" 14'-5" 3'-9" 6'-11" 3'-9" 3'-3" STAIRW ELL M ASTER BATH BATH BEDRO O M BEDRO O M C LO SET C LO SET BALC O NY C LO SET M ASTER BDRM C LO SET C LO SET A-03.01 AAA-03.01A-03.01 BBA-03.011/4 INCH = 1 FEET 0 1 2 3 4 5 10 15 GRAPHIC SCALE : 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN NORTH PROPOSED FLOOR PLAN A-01.02 1/4" = 1' 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM LEGEND: NEW CONSTRUCTION WALL Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano 1 PROPOSED REAR (NORTH) ELEVATION2 SC : 1/4" = 1'-0" PROPOSED FRONT (SOUTH) ELEVATION SC : 1/4" = 1'-0" 12 4 12 4 10'-0" 10'-0"1'-6"21'-6"25°25°10'-0" VERTIC AL LINE FRO MNATURAL G RADE AT BUILDING PRO PERTY LINE18" ABO VE NATURAL G RADE ABO VE NATURAL G RADE (2 Nd Floor) ABO VE F.F. 26'-3" TO P HT. 12'-6" PLATE HT. ENTRY ABO VE F.F. ABO VE NATURAL G RADE F.F. 21' PLATE HT. D A Y L IG HT LI N E C LASS A TILE RO O FING . INSTALLATIO N PER M ANUFAC TURE REC O M M ENDATIO N. VERIFY W ITH O W NER O R DESIG NER FO R C O LO R. (EXAM P.:EAG LE RO O F TILE W ITH PRO DUC T NUM BER :4678 O R EQ UAL) 10' PLATE HT. F.F. NATURAL G RADE LINE 5' FRO M PRO PERTY LINE TO THE EXTERIO R W ALL W IN. SILL 36" ABO VE F.F. 10301 DAYLI G HT LINE 10'-0" VERTIC AL LINE FRO MNATURAL G RADE AT BUILDING PRO PERTY LINE5'-3" FRO M PRO PERTY LINE TO THE EXTERIO R W ALL 12 4 12 4 10'-0" 1'-6"10'-0"21'-6"2'-5"25°25°(2 Nd Floor) ABO VE F.F. 10' PLATE HT. F.F. DAYLI G HT LINE 10'-0" VERTIC AL LINE FRO MNATURAL G RADE AT BUILDING PRO PERTY LINE18" ABO VE NATURAL G RADE C LASS A TILE RO O FING . INSTALLATIO N PER M ANUFAC TURE REC O M M ENDATIO N. VERIFY W ITH O W NER O R DESIG NER FO R C O LO R. (EXAM P.:EAG LE RO O F TILE W ITH PRO DUC T NUM BER :4678 O R EQ UAL) 5'-3" FRO M PRO PERTY LINE TO THE EXTERIO R W ALL 26'-3" TO P HT. F.F. D A Y L IG HT LI N E 21' PLATE HT.10'-0" VERTIC AL LINE FRO MNATURAL G RADE AT BUILDING PRO PERTY LINEABO VE NATURAL G RADE ABO VE F.F. W IN. SILL 36" ABO VE F.F. 5' FRO M PRO PERTY LINE TO THE EXTERIO R W ALL W indow is cantilevered from the exterior w all 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com PROPOSED ELEVATIONS 1/4" = 1' THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN A-02.01 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM "ANY CHANGES TO THE APPROVED COLORS, MATERIALS, AND EXTERIOR FINISHES SHALL BE REVIEWED AND APPROVED BY THE CITY OF CUPERTINO PLANNING DIVISION PRIOR TO INSTALLATION/APPLICATION." Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano SC : 1/4" = 1'-0" 2 1 PROPOSED LEFT (WEST) ELEVATION SC : 1/4" = 1'-0" PROPOSED RIGHT (EAST) ELEVATION 4 12 20302030 3030 10'-0" 10'-0"21'-6"1'-6"F.F. ABO VE F.F. F.F. ABO VE F.F. 18" ABO VE NATURAL G RADE 26'-3" TO P HT. ABO VE NATURAL G RADE 21' PLATE HT. (2 Nd Floor) 10' PLATE HT. C LASS A TILE RO O FING . INSTALLATIO N PER M ANUFAC TURE REC O M M ENDATIO N. VERIFY W ITH O W NER O R DESIG NER FO R C O LO R. (EXAM P.:EAG LE RO O F TILE W ITH PRO DUC T NUM BER :4678 O R EQ UAL) W IN. SILL 60" ABO VE F.F. W IN. SILL 60" ABO VE F.F. W IN. SILL 60" ABO VE F.F. 2030 2030 Electrical M eter 20302030 3030 3030 3030 50605060 10461046 3046 4 12 1'-6"10'-0" 21'-6"10'-0"(2 Nd Floor) 10' PLATE HT. C LASS A TILE RO O FING . INSTALLATIO N PER M ANUFAC TURE REC O M M ENDATIO N. VERIFY W ITH O W NER O R DESIG NER FO R C O LO R. (EXAM P.:EAG LE RO O F TILE W ITH PRO DUC T NUM BER :4678 O R EQ UAL) ABO VE F.F. 18" ABO VE NATURAL G RADE F.F. 26'-3" TO P HT. F.F. ABO VE F.F. W IN. SILL 60" ABO VE F.F. ABO VE NATURAL G RADE 21' PLATE HT. W IN. SILL 60" ABO VE F.F. 2030 2030 2030 2030 3080 2868 G as M eter 20302030 2880 2880 5050 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS PROPOSED ELEVATIONS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 1/4" = 1' A-02.02 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM "ANY CHANGES TO THE APPROVED COLORS, MATERIALS, AND EXTERIOR FINISHES SHALL BE REVIEWED AND APPROVED BY THE CITY OF CUPERTINO PLANNING DIVISION PRIOR TO INSTALLATION/APPLICATION." Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano 10295 MENHART LN. SC : 1/4" = 1'-0" 3 STREETSCAPE ELEVATION 1 A - A CROSS SECTION SC : 1/4" = 1'-0" 2 B - B CROSS SECTION 10307 MENHART LN. 10'-0"21'-6"10'-0" 1'-6"(2 Nd Floor) 10' PLATE HT. ABO VE F.F. 18" ABO VE NATURAL G RADE F.F. 26'-3" TO P HT. F.F. ABO VE F.F. ABO VE NATURAL G RADE 21' PLATE HT. KITC HEN & FAM ILY LIVING M ASTER BEDRO O M BEDRO O M 286 8 3080 24802480 2880 2880 2030 203010'-0"10'-0"10'-0"21'-6"10'-0" 1'-6"ATTIC KITC HEN & FAM ILY PO W DER (2 Nd Floor) 10' PLATE HT. ABO VE F.F. 18" ABO VE NATURAL G RADE F.F. 26'-3" TO P HT. F.F. ABO VE F.F. ABO VE NATURAL G RADE 21' PLATE HT. 248010080 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: SECTIONS and STREETSCAPE ELEVATION 1/4" = 1' A-03.01 DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano UP UP Sky L. 30"x24" Sky L. 30"x24"D/WREF.105010502650 5060 50601046104630465060 505015'-0" X 28'-3" 5'-0" X 5'-0" 20'-0" X 20'-0" 5'-0" X 8'-1" 3'-4" X 3'-3" 15'-0" X 14'-1" 6'-3" X 3'-3" 11'-1" X 10'-8"5'-1" 20'-0"20'-0" 2'-9" 28'-7"10'-7"24'-7" 3'-11"13'-0"6'-9"20'-10"2'-11" 3'-6"11'-7"3'-4"15'-10" 20'-5"21'-4" 22'-4" 22'-0" 14'-3" 3'-6" 4'-1" 3'-6" 8'-0"28'-3"18'-5"13'-6" 14'-9"9'-4"BEDRO O M SLO PETANKLESS W A TER HEA TER 6' A BO VE A G A RA G E FLO O R BELO W F.F. BELO W F.F. 18" 12"W A. DR. G ARAG E KITC HEN & FAM ILY A-03.01 A-03.01 AA LAUNDRY UTILITYA-03.01LIVING BATH PO W DER BBA-03.01J H F G I J1 F1 20302030 5050 5050 2030 203020302030 2030 3030 3030 30305650 20302030 2030 5'-4" X 2'-4" 13'-9" X 11'-6" 8'-2" X 3'-3" 10'-0" X 5'-0" 10'-2" X 2'-0" 10'-0" X 10'-0" 3'-0" X 1'-6" 8'-0" X 5'-0" 9'-11" X 10'-0" 6'-2" X 2'-4" 10'-2" X 5'-0" 2'-2" X 9'-2" 6'-7" 16'-0" 2'-7"14'-9"10'-1"10'-11"14'-11" 19'-8" 13'-8"1'-0"10'-10"10'-5" 3'-3" STAIRW ELL M ASTER BATH BATH BEDRO O M BEDRO O M C LO SET C LO SET BALC O NY C LO SET M ASTER BDRM C LO SET C LO SET A-03.01 AAA-03.01A-03.01 BBA-03.01A B C E D A1 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com DEC O RAM O ULD Feather River Doors THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: A1 445.02 TYPE SQ R. EDG E - 4" HT. X 2" DPT. DRAWN BY :C LO PAY REVISION DATE AMS BRO W N C O LO R BY OWNERSHIP: 2'-9" X 3'-4" 9.16F1 E X TE R I O R M ATER I AL SC H E DULE DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN RO O F EXTERIO R TRIM 1/8" = 1' A-06.01 DIAGRAMS and SCHEDULES DO O R BRO W N C O LO R M ILG ARD W INDO W S STUC C O 1020.78 TILE RO O FING TITLE SM O O TH TUSC ANY / W HITE SIDING E TOTAL BUILDING AREA 2289 G ARAG E DO O R FLOORS SIZE 10'-10" X 13'-8" AREAS (SQF) TOTAL 6'-7" X 1'-0" B A 6.5 C 10'-5" X10'-11" 113.71 D 16'-0" X 14'-11" 238.66 I 22'-4" X 15'-10" 353.61 J 6'-9" X 3'-6" 148.05 23.62 20'-5" X 20'-10" 425.34 SPACES 823.04 INFO 2ND FLOOR GARAGE F G H 2'-7" X 10'-1" 26.04 14'-9" X 19'-8" 290.08 21'-4" X 22'-0" 469.33 14'-3" X 11'-7" 165.06 1ST FLOOR FLOOR AREA DIAGRAM(PROPOSED PLAN): SCALE: 1/8" : 1' STUC C O TILE RO O FING 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 6'-9" X 2'-11" 19.68J1 SMA R-2017-40 02/08/18 Erick Serrano UP UP Sky L. 30"x24" Sky L. 30"x24"D/WREF.2868105010502650 3080 16080 30685060 50601046104630462468 36801680 5060 10080 2480 28683680 28805050 15'-0" X 28'-3" 5'-0" X 5'-0" 20'-0" X 20'-0" 5'-0" X 8'-1" 3'-4" X 3'-3" 15'-0" X 14'-1" 6'-3" X 3'-3" 11'-1" X 10'-8" 16'-5" 19'-7" BEDRO O M SLO PETA NKLESS W A TER HEA TER 6' A BO VE A G A RA G E FLO O R BELO W F.F. BELO W F.F. 18" 12"W A. DR. G ARAG E KITC HEN & FAM ILY A-03.01 A-03.01 AA LAUNDRY UTILITYA-03.01LIVING BATH PO W DER BBA-03.01 DRIVE W AY PAVERS PERVIO US M ATERIAL LO W IM PAC T DEVELO PM ENT M ULC H M YO PRO UM NEW TREE C RAPE M YRTLE 24 INC H BO X 6 FT HEIG HT TURF AREA TURF AREA M ULC H DO UBLE DW ARF FESC UE W ITH BO NSAI BLEND 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 1/8" = 1' A-07.01 CONCEPTUAL LANDSCAPE 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano 15 '-0" 15 '-0" 15 '-7" 5'-2"17'-0"15'-1" 15'-0" 16'-9" 15'-0"9'-3"18'-0"25'-6" 5'-1"25'-6"26'-3"25'-0"26'-1"15'-5" 15'-7"19'-0" 5'-0" 5'-8"33'-4"24'-3"30°FRO NT PO RC HFRO NT PO RC H101.16' 105.00'57.00 ' 43 .05' Balcony Sky L. Sky L. FRONT YARD:43.05'X20'= 860 SQF PAVING AREA: DRIVE WAY(360)+ WALKWAY(70)/860=50%(860) FRONT YARD PAVING SURFACE AREA: DRIVE W AY PAVERS PERVIO US M ATERIAL LO W IM PAC T DEVELO PM ENT"N" 6' HEIG HT W O O DEN FENC E20' FRO NT SETBAC K "N " 6' HEIG HT W O O DEN FENC E "N " 6' HEIG HT W O O DEN FENC EFRO NT PO RC H REAR PO RC H 2ND Floor 2ND Floor 2ND Floor2ND Floor2ND Floor2ND Floor 4 : 124 : 12 4 : 124 : 12M ENHART LN. NEW TREE C RAPE M YRTLE 24 INC H BO X 6 FT HEIG HT"E" 4" PEAC H TREE to be rem oved 2ND Floor 2ND Floor1ST Floor1ST Floor1ST Floor1ST Floor 2ND Floor 1ST Floor 1ST FloorG G G G 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS BY OWNERSHIP: DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM NTS PRIVACY PLANTING PLAN A-07.02 Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 40' 50' 35'-40' MAX. PLANTING DIST. 35' NOTE: THE MINIMUM TREE SIZE SHALL BE 24" BOX MINIMUM AND A MINIMUM OF 8' HEIGH NOTE: THE MINIMUM SHRUB SIZE SHALL BE 15 GALLON MINIMUM AND A MINIMUM OF 6' HIGH PLANTED HEIGHT 12'-15' 20'-25' NON DECIDUOUS SHRUB HEIGHT SPREAD E. C INAM O M O M C AM PHO RA-C AM PHO R 10' MAX. PLANTING DIST. NON DECIDUOUS TREES HEIGHT TO 80' SPREAD 10' 30'B. M ELALEUC A LNARFO LA-FLAXLEAF PAPERBAC K A. C EDRUS DEO DARA-DEO DARA C ENDAR 6' C . PINUS HELIPENSIS-ALLEPPO PINE 40'-60' 10' D. EUC AL YPTUS PO LYANTHEM O S-SILVERDO LLAR 20'-60' 5' I. PITTO SPO RUM TENUIFO LIUM 10'-15' 40' J. PITTO SPO RUM C RASSIFO LIUM 20' 60' K. PITTO SPO RUM UNDULATUM -VIC TO RIAN BO X 20' 3'-6' L. C UPRESSUS SEM PERVERNS-ITALIAN C YPRESS 5' 25' M . PO DO C ARPUS G RAC ILIO R-FERN PINE 15'-40' 20' 20' 40' N. PRIVET LIG USTRUM -G LO SSY PRIVET 40' 15'-20' 8' 15'-40' F. ARBUTUS M ARINA G . M AG NO LIA G RANDIFLO RA H. PITTO SPO RUM EUG ENO IDES 50' 20' 40' 15' 80' 20' 8' 60'5' O . LAURUS NO BILIS-G REC IAN LAUREL 5'20' 20' 10'15'-40' P. RHUS LANC IA-AFRC AN SUM AC 20' 10'25' SMA R-2017-40 02/08/18 Erick Serrano EXISTING FLOOR PLAN SC : 1/4" = 1'-0" 1 D/WREF. 2880 2468 10080 3080 288024682868 28802468 2680 15'-1" X 20'-0" 24'-9" X 22'-8" 8'-0" X 5'-0" 13'-0" X 12'-0" 13'-0" X 13'-2" 10'-0" X 11'-0" 5'-0" X 7'-1" 8'-0" X 5'-0" 21'-4" X 20'-0"57'-3"13'-9"5'-5" 5'-4" 12'-5" 20'-4" 38'-10" 15'-1"4'-8" 5'-9" 13'-4" 7'-6"6'-0"43'-9"20'-5" 23'-4"1'-5" 38'-10" 16'-11" 4'-9" 15'-9" 1'-5" 3'-0"0'-4"4'-8" 10'-0" 1'-1" GARAGE LIVING BEDROOM KITCHEN & DINNING BEDROOM MASTER BDRM CLOSET BATH BATH 1/4 INCH = 1 FEET 0 1 2 3 4 5 10 15 GRAPHIC SCALE : 2275 S. BASCOM AVE., SUITE 1406 CAMPBELL, CA 95008 Tell: (415) 254.1606 e-MAIL: office@AMSDesignllp.com RA-01.01 THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. REVISION TABLE: DRAWN BY : REVISION DATE AMS NORTH BY EXISTING PLAN OWNERSHIP: 1/4" = 1' DESIGN ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION, GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE PRECEDING AT HIS OWN RISK. OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS- DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB- CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED WORK. SCALE : PROJECT ID : DATE : SHEET NUMBER: SEP. 2017 A.M.S SHEET TITLE: DESIGN 21060 HOMESTEAD RD. SUITE 216 CUPERTINO, CA 95014 TEL:(408) 992-1229 e-MAIL: NILSENEINC@GMAIL.COM LEGEND: EXISTING WALL TO BE REMOVED Tétwx{ `táÜÉâÜ 10301 MENHART LN., CUPERTINO, CA MENHART RESIDENCE D-1706-05 SMA R-2017-40 02/08/18 Erick Serrano R-2017-40 02/08/18 Erick Serrano