Loading...
approved plans R-2018-01.pdfPROPOSED 1ST STORY ADDITION (618 SQ.FT.) EXISTING 1ST STORY (1,341 SQ.FT.) PROPOSED 2ND STORY ADDITION (35 SQ.FT.) EXISTING GARAGE (457 SQ.FT.) PROPOSED COVERED PORCH ADDITION (30 SQ.FT.) EXISTING 2ND STORY (790 SQ.FT.) 11' - 1" 8' - 3" 13' - 1 1/2"3' - 8"17' - 4"3' - 3"10' - 8" EXISTING 1ST STORY (1,341 SQ.FT.) EXISTING GARAGE (457 SQ.FT.)21' - 11" 25' - 8" 51' - 8 5/8" 20' - 10"26' - 1"EXISTING 2ND STORY (790 SQ.FT.)26' - 2 1/4"31' - 6"10' - 8"15' - 6 1/4" 28' - 3" 3' - 3" & AND ANGLE @ AT < CENTERLINE ~ DIAMETER OR NUMBER # POUND OR NUMBER (E) EXISTING ACCT ACCOUSTICAL AD AREA DRAIN ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AGGR AGGREGATE AL ALUMINUM ANNLD ANNEALED APPR APPROXIMATE ASB ASBESTOS ASPH ASPHALT ASS'Y ASSEMBLY BD BOARD BITUM BITUMINOUS BLDG BUILDING BLK BLOCK BLL'G BLOCKING BM BEAM BOT BOTTOM CAB CABINET CB CATCH BASIN CEM CEMENT CER ERAMIC CI CAST IRON CG CORNER GUARD CLG CEILING CLK'G CAULKING CLO CLOSET CLR CLEAR CO CASED OPENING COL COLUMN CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINOUS CORR CORRIDOR CTSK COUNTERSUNK CNTR COUNTER CTR CENTER DBL DOUBLE DEPT DEPARTMENT DF DRINKING FOUNTAIN DET DETAIL DIA DIAMETER DIM DIMENSION DISP DISPENSER DN DOWN DO DOOR OPENING DR DOOR DWR DRAWER DS DOWNSPOUT DSP DRY STANDPIPE DWG DRAWING FA FIRE ALARM FB FLAT BAR FLR DRN FLOOR DRAIN FD FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CAB FIN FINISH FLR FLOOR FLASH FLASHING FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOS FACE OF STUD FP FIREPROOF FS FULL SIZE FT FOOT or FEET FTG FOOTING FURR FURRING FUT FUTURE GA GAUGE GALV GALVANIZED GB GRAB BAR GL GLASS GND GROUND GYP GYPSUM HB HOSE BIBB HC HOLLOW CORE HDWD HARDWOOD HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT ID INSIDE DIAMETER (DIM) INSUL INSULATION INT INTERIOR JAN JANITOR JT JOINT KIT KITCHEN LAB LABORATORY LAM LAMINATE LAV LAVATORY LKR LOCKER LL LEAD LINED LT LIGHT PROST PRECAST PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLYWD PLYWOOD PR PAIR PT POINT PTD PAPER TOWEL DISPENSER PTD/R COMBINATION PAPER TPWER DISPENSER & RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE QT QUARRY TILE R RISER RAD RADIUS RD ROOF DRAIN REFR REFERENCE REF REFRIGERATOR RGTR REGISTER REINF REINFORCED REQ'D REQUIRED RB RESILIENT BASE RM ROOM RO ROUGH OPENING RWD REDWOOD RWL RAIN WATER LEADER S SOUTH SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SMOKE DETECTOR SECT SECTION SFD SMOKE / FIRE DAMPER SH SHELF SHR SHOWER E EAST EA EACH EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL EMER EMERGENCY ENCL ENCLOSURE EP ELECTRICAL PANELBOARD EQ EQUAL EQP EQUIPMENT EWC ELECTRIC WATER COOLER (E) EXISTING EXPO EXPOSED EXP EXPANSION EXT EXTERIOR SHT SHEET SMS SHEET METAL SCREW SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SQ SQUARE SS STAINLESS STEEL SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STO STORAGE STRL STRUCTURAL SUSP SUSPENDED SYM SYMMETRICAL T TREAD TB TOWEL BAR TC TOP OF CURB TEL TELEPHONE TER TERRAZZO T&G TONGUE AND GROOVE THK THICK TP TOP OF PAVEMENT TPD TOILET PAPER DISPENSER TS TUBE STEEL TW TOP OF WALL TYP TYPICAL UNF UNFINISHED UNO UNLESS OTHERWISE NOTE UR URINAL VERT VERTICAL VEST VESTIBULE W WEST W/ WITH WC WATER CLOSET WD WOOD W/O WITHOUT WP WATERPROOF WSCT WAINSCOT WSP WET STANDPIPE WT WEIGHT MAX MAXIMUM MC MEDICINE CABINET MECH MECHANICAL MEMB MEMBRANE MTL METAL MFGR MANUFACTURER MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MO MASONRY OPENING MTD MOUNTED MUL MULLION (N) NEW NIC NOT IN CONTRACT No or # NUMBER NOM NOMINAL NTS NOT TO SCALE OA OVERALL O/ OVER OC ON CENTER OD OUTSIDE MIAMETER (DIM) OFF OFFICE OPN'G OPENING OPP OPPOSITE OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT As indicated A 0.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103TITLE SHEET 01/12/2018 1. THESE DRAWINGS WERE PREPARED IN ACCORDANCE WITH THE 2013 CALIFORNIA RESIDENTIAL CODE (CRC) & ALL APPLICABLE LOCAL CODES AND LEGISLATION ADOPTED BY THE CITY. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTORS AND SUBCONTRACTORS TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS INDICATED ON THESE DRAWINGS AND MAKE KNOWN ANY DISCREPANCIES PRIOR TO COMMENCING THEIR WORKS. 3. THESE DRAWINGS ARE INTENDED FOR USE IN A NEGOTIATED CONSTRUCTION CONTRACT AND, THEREFORE, MAY NOT SPECIFICALLY DETAIL OR SPECIFY MATERIAL AND / OR MANUFACTURERS. THE CONTRACTORS SHALL PROVIDE ALL SAMPLES AND OR SPECIFICATION SHEETS AS REQUIRED TO ASSIST OWNERS OR THEIR AGENT IN MAKING MATERIAL SELECTIONS. FOR THE PURPOSE OF ESTIMATING, THE CONTRACTORS SHALL USE THE MATERIALS SELECTED BY THE OWNERS, OR IN ABSENCE OF SAME, THEY SHALL PROVIDE AN ALLOWANCE AMOUNT WITH CONDITION OF ANY COST ESTIMATE. ALL MATERIALS SPECIFIED IN THESE DRAWINGS SHALL BE INCLUDED IN SUCH ESTIMATE. 4. NO GUARANTEE OF QUALITY OF CONSTRUCTION IS IMPLIED OR INTENDED BY THE ARCHITECTURAL DOCUMENT, AND THE CONTRACTORS SHALL ASSUME FULL RESPONSIBILITY FOR ANY OR ALL CONSTRUCTION DEFICIENCIES. 5. THE GENERAL CONTRACTOR SHALL HOLD HARMLESS, INDEMNIFY AND DEFEND THE DESIGNER FROM ANY ACTION INITIATED BY THE INITIAL OWNER OR ANY SUBSEQUENT OWNERS FOR CONSTRUCTION DEFICIENCIES, MODIFICATIONS OR SUCH CONDITIONS WHICH MAY BE BEYOND THE CONTROL OF DESIGNER. 6. THE CONTRACTORS SHALL REVIEW AND RECORD THE CONDITIONS OF ALL EXISTING SITE IMPROVEMENTS INCLUDING PAVED AREAS. THEY SHALL MAKE KNOWN ALL EXISTING DAMAGED OR DISREPAIRED ITEMS AND CONDITIONS THAT MAY WORSEN DUE TO THE CONSTRUCTION. ALL ITEMS IN GOOD CONDITION SHALL BE MAINTAIN IN THEIR PRESENT CONDITION AND ANY REPAIR OR DAMAGE WHICH OCCURS DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTORS. 7. CONTRACTORS SHALL THOROUGHLY EXAMINE THE SITE AND SATISFY THEMSELVES AS OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTORS SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING THEIR WORK AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME. NO EXTRA COMPENSATION WILL BE ALLOWED TO THE CONTRACTORS FOR THE EXPENSES DUE TO THEIR NEGLECT TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS WHICH MAY AFFECT THEIR WORK. 8. ALL NEW INTERIOR PAINT COLOR, FLOOR, WALLS AND CEILING FINISHES SHALL BE SELECTED BY OWNER AT THE TIME WHEN IT IS NECESSARY FOR THE COMPLETION OF THE PROJECT. 9. ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE LATEST ADOPTED CITY STANDARDS. THE STORING OF GOODS AND MATERIALS ON SIDEWALK AND / OR STREET WALL NOT BE ALLOWED UNLESS THE CONTRACTOR HAS APPLIED AND SECURED A SPECIAL PERMIT WHICH ALLOWS SUCH STORAGE TO BE PLACED. GENERAL NOTES VICINITY MAP SCOPE OF WORK 1. CONSTRUCTION SITE SHALL BE ENCLOSED BY 6' OPAQUE FENCE AT ALL TIMES DURING CONSTRUCTION. 2. NO CONSTRUCTION MATERIAL, EQUIPMENT, PORTABLE TOILETS, TRASH CONTAINERS, OR DEBRIS SHALL BE PLACED IN THE PUBLIC RIGHT-OF-WAY. 3. A TRASH CONTAINER SHALL BE MAINTAINED ON SITE AT ALL TIMES AND DEBRIS ON SITE WHICH COULD OTHERWISE BLOW AWAY, SHALL BE REGULARLY COLLECTED AND PLACED IN CONTAINER. 4. ALL CONSTRUCTION DEBRIS (WOOD SCRAPS AND OTHER DEBRIS, WHICH CANNOT BLOW AWAY) SHALL BE PILED WITHIN THE PROPERTY LINES OF THE PROJECT IN A NEAT AND SAFE MANNER. 5. THE PROJECT SHALL HAVE A SIGNAGE VIEWABLE FROM THE PUBLIC STREET THAT INDICATES THE HOURS OF CONSTRUCTION AS: MON- FRI FROM 7:30 AM TO 6 PM, SATURDAYS FROM 9AM TO 5 PM. 1. THIS PROJECT IS TO ADD A TOTAL OF 696 SQ.FT. TO AN EXISTING 2,131 SQ.FT. TWO STORY SINGLE FAMILY DWELLING(NOT INCLUDING GARAGE OF 457 SQ.FT.) WITH NEW COVERED PORCH. AND REMODEL EXISITING 1,528 SQ.FT. OWNER : PROJECT ADDRESS : ASSESSOR'S PARCEL NUMBER(A.P.N.): OCCUPANCY GROUP : CONSTRUCTION TYPE : BUILDING ZONE : LAND USE: GENERAL PLAN: EXISTING USE: PROPOSED USE: AVERAGE SLOPE OF LOT: AGE OF RESIDENCE: SITE AREA: EXISTING 1ST FLOOR AREA: EXISTING 2ND FLOOR AREA: TOTOAL EXISTING FLOOR AREA: PROPOSED 1ST FLOOR AREA: PROPOSED CEILING OVER 16'-0" HEIGHT: RESERVE FUTURE GARAGE UPGRADE: PROPOSED 2ND FLOOR AREA: TOTAL PROPOSED FLOOR AREA: TOTAL BUILDING AREA: PERCENTAGE OF ADDITION: FLOOR AREA RATIO (F.A.R): ALLOWABLE FAR : EXISTING GARAGE: LOT COVERAGE: EXISTING PROPOSED IMPERVIOUS PAVING / DRIVEWAY: TOTAL IMPERVIOUS AREA: BUILDING HEIGHT: NUMBER OF STORIES: 1ST AND 2ND FLOOR RATIO PROPOSED BLDG. SET BACK: APPLICABLE BUILDING CODE: NOTES PROPOSED RENOVATION FOR 21381 MILFORD DR., CUPERTINO, CA 95014 NORTH JOHN CHEN & IMELDA BAMBANG 21381 MILFORD DR., CUPERTINO, CA 95014 326-41-103 R-3/U1 V-B R1-7.5 RES LOW 1-5 LOW DENSITY RESIDENTIAL SINGLE FAMILY RESIDENTIAL SINGLE FAMILY RESIDENTIAL EXISTING ORIGINAL BUILDING WAS BUILT IN 1968 7,504 SQ.FT. (GROSS/NET) 1,341 SQ.FT. + 457 SQ.FT.(GARAGE) = 1,798 SQ.FT. 790 SQ.FT. 1,798+790 = 2,588 SQ.FT. (INCLUDING GARAGE) 618 SQ.FT.(1ST FLOOR) + 30 SQ.FT.(COVERED PORCH) = 648 SQ.FT. (NEW ADDITION) 53 SQ.FT. (NEW ADDITION CEILING AREA) DOUBLE COUNT 4 SQ.FT. (FUTURE GARAGE UPGRADE) 35 SQ.FT. (NEW ADDITION) 648+53+4+35 = 740 SQ.FT. 2,588 SQ.FT.(EXISTING) + 740 SQ.FT.(NEW ADDITION) = 3,328 SQ.FT. 656 / 2,588 = 25.3% < 50% 7,504 SQ.FT. x 0.45 = 3,377 SQ.FT. 3,328 / 7,504 = 44.3% < 45% OK 457 SQ.FT. 24.0% (1,798 / 7,504) 32.1 % ((1,759+648)/7,504) 458 SQ.FT. 22'-4" FT EXISTING TWO 825 SQ.FT.(2ND FLOOR) / 2,446 SQ.FT(1ST FLOOR) = 0.337 PROJECT DATA PLAN CHECK SUBMITTAL ACLARA ENGINEERING CONSULTANT ENGINEER: CLARA TING P.O. BOX 53892 SAN JOSE, CA 95153 TEL: (408)228-7526 ABBREVIATIONS AREA CALCULATION DRAWING INDEX PROJECT LOCATION A 0.0 TITLE SHEET A 1.0 SITE PLAN A 2.0 EXISTING AND PROPOSED 1ST FLOOR A 2.1 EXISTING/ PROPOSED 2ND FLOOR AND STREET VIEW A 3.0 PROPOSED ELEVATIONS A 3.1 SECTIONS A 4.0 ROOF PLAN (NEW & EXISTING) A 5.0 DETAILS A 6.0 CUPERTINO CONSTRUCTION BEST MANAGEMENT PRACTICES GB-1 GREEN BUILDING CHECKLIST SU-1 TOPOGRAPHIC & BOUNDARY SURVEY 1. SUBMIT PLANS FOR FINAL ARCHITECTURAL REVIEW TO THE PLANNING DIVISION AND OBTAIN ARCHITECTURAL APPROVAL PRIOR TO ISSUANCE OF BUILDING PERMITS. SAID PLANS TO INCLUDE, BUT NOT BE LIMITED TO: SITE PLANS, FLOOR PLANS, ELEVATIONS, LANDSCAPING, LIGHTING AND SIGNAGE. 2. EXTERIOR LIGHTING ON ALL THE ENTRANCES ON THE FIRST FLOOR SHALL BE SHIELDED TO DIRECT LIGHT TO THE GROUND AND PROTECT THE NEIGHBORING PROPERTIES FROM EXCESSIVE GLARE. 3. DEVELOPER IS RESPONSIBLE FOR COLLECTION AND PICK-UP OF ALL TRASH AND DEBRIS ON-SITE AND ADJACENT PUBLIC RIGHT-OF-WAY. 4. CONSTRUCTION ACTIVITY SHALL BE LIMITED TO THE HOURS OF 7:00 A.M. TO 6:00 P.M. WEEKDAYS AND 9:00 A.M. TO 6:00 P.M. SATURDAYS FOR PROJECTS WITHIN 300 FEET OF A RESIDENTIAL USE AND SHALL NOT BE ALLOWED ON RECOGNIZED STATE AND FEDERAL HOLIDAYS. 5. INCORPORATE BEST MANAGEMENT PRACTICES (BMPS) INTO CONSTRUCTION PLANS AND INCORPORATE POST CONSTRUCTION WATER RUNOFF MEASURES INTO PROJECT PLANS IN ACCORDANCE WITH THE CITY'S URBAN RUNOFF POLLUTION PREVENTION PROGRAM STANDARDS PRIOR TO THE ISSUANCE OF PERMITS, INCLUDING THE DISCONNECTION OF ROOF DOWNSPOUTS TO DRAIN OVER LANDSCAPED YARDS ON SITE. 6. LANDSCAPING INSTALLATION SHALL MEET CITY WATER CONSERVATION CRITERIA IN A MANNER ACCEPTABLE TO THE DIRECTOR OF PLANNING AND INSPECTION. NEW LANDSCAPE AREAS OF 500 SQUARE FEET OR/MORE OR REHABILITATED LANDSCAPE AREAS OF 2,500 SQUARE FEET OR MORE SHALL CONFORM TO THE CALIFORNIA DEPARTMENT OF WATER RESOURCES WATER EFFICIENT LANDSCAPE ORDINANCE. CONDITIONS OF APPROVAL PROPOSED 2ND FLOOR EXISTING 1ST FLOOR 1/12/2018 BUILDING PERMIT & BID LOT SIZE 7,504 SQ.FT. LIVING AREA (E)1ST FLOOR 1,341 SQ.FT. (E)2ND FLOOR 790 SQ.FT. (N)1ST FLOOR ADDITION 618 SQ.FT. (N)2ND FLOOR ADDITION 35 SQ.FT. TOTAL LIVING AREA 2,784 SQ.FT. (E)GARAGE 457 SQ.FT. (N)COVERED PORCH 30 SQ.FT. LOT COVERAGE: 32.6% 1,341+618+457+30 = 2,446 2,446/ 7,504 = 0.326 TOTAL ADDITION: 618+35+30 = 683 SQ.FT. EXISTING 20'-2" 39'-4" 12'-4" 6'-0" FRONT REAR L. SIDE R. SIDE PROPOSED 20'-2" 39'-4" 12'-4" 6'-0" EXISTING 41'-7" 39'-4" 12'-4" 26'-2" PROPOSED 41'-7" 39'-4" 12'-4"(E) 26'-2" 2016 CBC, CMC, CPC, CFC, CEC, CRC, T-24 PART 2-5, 2016 CALIFORNIA ENERGY STANDARD,& CITY OF SANTA CLARA ORDINANCES. ANY OTHER APPLICABLE LOCAL & STATE LAWS & REGULATIONS SETBACK 1ST FLOOR 2ND FLOOR PROPOSED 1ST FLOOR EXISTING 2ND FLOOR 02/01/2018 RESPONSE TO PC 1 1 R-2018-01 03/13/18 Ellen Yau FUR.20' - 2 1/2"10' - 9"REAR SETBACK25' - 0"SETBACK 5' - 0" PROPERTY LINE 70.00' PROPERTY LINE 70.00'PROPERTY LINE 107.20'PROPERTY LINE 107.20'MILFORD DR. NORTH PROPOSED 1ST STORY ADDITION (618 SQ.FT.) EXISTING TWO STORY SINGLE FAMILY DWELLING (1ST FLOOR 1,301 SQ.FT.) (2ND FLOOR 790 SQ.FT.) PROPOSED 2ND STORY ADDITION (E) DRIVEWAY TO BEREMAINEDSIDEWALK GRAVEL GRAVEL SIDEWALK GRAVEL 6' WOOD FENCE WALKWAY WALKWAY VEGETATION FRONT YARD N)WALKWAY BACK YARD EXISTING GARAGE (457 SQ.FT.) PROPOSED COVERED PORCH (30 SQ.FT.) 24"Ø REDWOOD (E) FENCE TO BE REMAINED 10"Ø (E) FENCE TO BE REMAINED 2ND FLOOR SETBACK39' - 4 3/4"2ND FLOOR SETBACK 26' - 2" 2ND FLOOR SETBACK 12' - 4" 16"Ø 10"Ø 10"Ø REDWOOD 18"Ø 10"Ø2ND FLOOR SETBACK41' - 7 1/2"6' - 0" 1' - 7" 3' - 0" (N)WALKWAY 1' - 3 1/2"18' - 8 1/2" DECK LANDING WALKWAY FIRE PIT CONC. PATIO 5' W.C.E 5' P.U.E. & 10' W.L.E. 1 SETBACK20' - 0"12' - 4"SETBACK25' - 0"SETBACK 5' - 0" PROPERTY LINE 70.00' PROPERTY LINE 70.00'PROPERTY LINE 107.20'PROPERTY LINE 107.20'MILFORD DR. NORTH EXISTING TWO STORY SINGLE FAMILY DWELLING DRIVEWAY SIDEWALK GRAVEL GRAVEL SIDEWALK GRAVEL 6' WOOD FENCE W AL K W A YWALKWAY VEGETATION FRONT YARD WALKWAY BACK YARD ENTRY PORCH PLANTER DECK LANDING WALKWAY FIRE PIT CONC. PATIO WALKWAY 10' - 9" 6' - 0" 8"Ø JUNIPER TREE TO BE REMOVE 5' W.C.E 5' P.U.E. & 10' W.L.E. 1 OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/8" = 1'-0" A 1.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103SITE PLAN 01/12/2018 1/8" = 1'-0" 1 PROPOSED SITE PLAN DRAINAGE NOTES: 1. 5% DRAINAGE AROUND/ AWAY FROM BUILDING FOR A MIN. DISTANCE OF 10FT. 2. ALTERNATELY, SWALE w/ SLOPE OF 2% SHALL BE LOCATED WITHIN OF BLDG FOUNDATION. NOTES: CONTRACTOR SHOULD VERIFY THE LOCATION OF CLEANOUT. IF CLEANOUT IS LOCATED MORE THAN 5' AWAY FROM PROPERTY LINE, CONTRACTOR SHOULD FOLLOW THE DETAILS AS SHOWN ON A4.0 FOR NEW CLEANOUTS INSTALLATION REQUIREMENT. 1 1/8" = 1'-0"2 EXISTING SITE PLAN R-2018-01 03/13/18 Ellen Yau WD WH FUR.UPFUR.WH UP WD (N)KITCHEN (N)DINING (E)FAMILY RM (N)STUDY (N)LAUNDER (N)HALL (N)PANTRY (N)LIVING RM (E)GARAGE (N)MASTER (E)LIVING RM (N)CLOSET (N)TANKLESS WATER HEATER (N)GAS FIREPLACE CRAWL SPACE ACCESS (N)POWDER 51' - 8"25' - 10 3/4"5' - 6 3/4" 11' - 11 1/2" 20' - 10" 11' - 0 3/4" 6' - 7 1/4" 14' - 9"21' - 10 3/4" 11' - 4 3/4" 14' - 3 1/2"4' - 9" 9' - 8 1/2" 4' - 5 1/2" 7' - 9 1/2" 10' - 7 1/2" 8' - 1 1/2"3' - 8 1/4" 3' - 4 1/2" 4' - 10 1/2"3' - 5"7' - 9"4' - 4"5' - 1"20' - 5 3/4" 3' - 9"6' - 9 3/4"3' - 8"7' - 10" 2 3 5 6 8 9 10 11 13 14 15 20 21 19 18 18 16 18 10 9 11 10 12 13 14 15 1 2 1 3 2 4 3 4 5 5 6 7 8 7 16 8 9 8 1 A 3.1 2 A 3.1 3 A 3.1 4 A 3.1 (N)M.BATH (N)WIC UNDER STAIR STORAGE 25 19' - 10" 6" AREA WITH CEILING OVER 16' HEIGHT (53 SQ.FT.) REMAIN NON- CONFORMING RESERVE MIN. 20' x 20' FOR FUTURE UPGRADE ADD 4 SQ.FT TO F.A.R. (2" x 20'-5 3/4" = 3.4 SQ.FT.) 1 1 FIREPLACE AND CHIMNEY TO BE REMOVED BEDROOM KITCHEN DINING LIVING RM FAMILY RM POWDER GARAGE 17' - 9 1/2" 20' - 2" 13' - 8 1/2"26' - 1 1/4"14' - 3 1/2"11' - 4 3/4" 21' - 10 3/4" 20' - 10"21' - 5 3/4" 3' - 11" 6' - 10" 21' - 8" 6" - INDICATES EXISTING WALL - INDICATES WALL TO DEMOLISHED - INDICATES NEW WALL - INDICATES WINDOW LEGEND - INDICATES TO DEMOLISHED - INDICATES NEW OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT As indicated A 2.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103EXISTING AND PROPOSED 1ST FLOOR 01/12/2018 1/4" = 1'-0"2 PROPOSED MAIN FLOOR 3/16" = 1'-0"3 EXISTING w/ DEMO Door Schedule Phase Mark Width Height Type Destination Comments Existing 1 18' - 0" 8' - 0" Overhead-Section al (E)GARAGE New 2 3' - 0" 7' - 0" Single-Decorative (N)LIVING RM New 3 3' - 0" 7' - 0" Single (N)MASTER New 4 2' - 4" 7' - 0" Single (N)WIC New 5 2' - 4" 7' - 0" Single (N)M.BATH New 7 2' - 8" 7' - 0" Single (N)HALL New 8 2' - 8" 7' - 0" Single (N)HALL New 9 2' - 6" 6' - 8" Single (N)KITCHEN New 10 6' - 0" 6' - 8" Sliding-2 panel (N)DINING New 11 10' - 0" 7' - 2" Sliding Four Panel (E)FAMILY RM New 12 2' - 8" 6' - 8" Single (N)STUDY New 13 3' - 0" 8' - 0" Single (N)LAUNDER New 14 3' - 0" 7' - 0" Single (N)LAUNDER Existing 15 2' - 6" 7' - 0" Single (E)GARAGE New 16 2' - 6" 6' - 8" Pocket (N)HALL New 17 7' - 2" 6' - 8" Sliding-Closet (E)BEDROOM 2 Existing 18 2' - 6" 6' - 8" Single (N)BEDROOM 3 New 19 9' - 8" 6' - 8" Sliding-Closet (N)BEDROOM 3 New 20 2' - 6" 6' - 8" Single (N)BATHROOM Existing 21 2' - 6" 6' - 8" Single (E)BEDROOM 2 Existing 22 2' - 8" 6' - 8" Single (E)MASTER New 23 2' - 8" 6' - 8" Pocket (N)W.I.C. Existing 24 2' - 6" 6' - 8" Single (N)M.BATH New 25 0' - 0" 0' - 0" Door-Opening (E)FAMILY RM New 26 2' - 4" 7' - 0" Single (E)FAMILY RM Window Schedule Phase Mark Width Height Type Destination Comments New 1 2' - 0" 5' - 0" Fixed (N)LIVING RM New 2 4' - 0" 5' - 0" Fixed (N)LIVING RM New 3 2' - 0" 5' - 0" Fixed (N)LIVING RM New 4 6' - 0" 5' - 0" Fixed (N)MASTER New 5 4' - 0" 2' - 0" Slider (N)M.BATH New 6 8' - 0" 4' - 0" Slider with Trim (E)LIVING RM New 7 1' - 6" 3' - 6" Fixed (N)KITCHEN New 8 1' - 6" 3' - 6" Fixed (N)KITCHEN New 9 6' - 0" 3' - 6" Slider with Trim (N)KITCHEN Existing 10 6' - 0" 3' - 0" Slider with Trim (N)STUDY Existing 11 8' - 0" 3' - 6" Slider Triple Pane (E)MASTER New 12 5' - 0" 3' - 6" Slider with Trim (N)M.BATH New 13 4' - 0" 2' - 0" Slider (N)M.BATH New 14 4' - 0" 2' - 0" Slider (N)BATHROOM Existing 15 6' - 0" 3' - 8" Slider Triple Pane (N)BEDROOM 3 New 16 6' - 0" 3' - 8" Slider Triple Pane (E)BEDROOM 2 New 17 2' - 0" 4' - 0" Fixed flower (N)HALL 8 ALL EXTERIOR WOOD DOORS SHALL BE SOLID CORE WITH WEATHER STRIP. 9 GARAGE CONSTRUCTION: (ONE HOUR RATED) 5/8" GYP. BD. TYPE "X" ON WALL, CEILING, AND POSTS. FIRE RESISTANT CAULKING AT PENETRATIONS. (SEE FIRE SEPARATION NOTS FOR MORE INFO.) FIRE SEPARATION WALL UP TO ROOF FRAMING, SEE FIRE SEPARATION NOTES FOR INFORMATION. 10 PROVIDE 4" DRYER VENT, DRYER SHALL BE A LISTED & APPROVED PRODUCT TESTED BY A RECOGNIZED TESTING AGENCY, IF THE VENT MORE THAN 14' LONG. 11 7.75" MAX. FOR IN-SWINGING DOORS & 1/2" MAX. FOR OUT-SWINGING DOORS FROM THE TOP OF THE THRESHOLD TO THE LANDING AT THE EXTERIOR DOORS. 13 INSTALL TANKLESS WATER HEATER 14 EXHAUST DUCT TO ROOF OR THRU WALL. PER 510.5.2 OF 2013 CPC. 15 INSTALL MIN. OF 3'X3' EXTERIOR LANDING. (CRC R902) & MAXIMUM SLOPE OF ANY LANDING SHALL NOT EXCEED 1/4" PER FOOT. (CRC R311.3) 16 LEVEL (E)FAMILY RM FLOOR WITH REST OF 1ST FLOOR. 17 PROVIDE AC CONDENSER UNITS SUPPORTED FROM THE GROUND SHALL REST ON A CONCRETE OR OTHER APPROVED BASE EXTENDING NOT LESS THAN 3" ABOVE THE GROUND LEVEL. CMC 1106.2. 18 VENTILATION @ LAUNDRY & WATER CLOSET ROOM TO COMPLY WITH 2016 CMC TABLE 402.1 & 504.6. 19 FURNACE COMBUSTION AIR TO COMPLY WITH CMC SECTION 701.1 FURNACE HAS A 94% AFUE. (THE BUILDING INSPECTOR NEEDS TO VERIFY ON SITE). INDICATE THE AFUE RATING NEAR THE ATTIC FURNACE. 20 R-15 INSULATION ON WALL OF UTILITY & LAUNDRY ROOMS. 21 T&P VALVE DRAIN LINE TO DISCHARGE TO THE EXTERIOR w/2% SLOPE. 25 1/2" GYPSUM BOARD ON THE ENCLOSED SIDE OF THE USEABLE SPACE UNDER INTERIOR STAIR. PER CRC 302.7 & CBC 1011.7.3 3 PROVIDE 18"x24" UNDERFLOOR ACCESS 4 PROVIDE 20"x30" ATTIC ACCESS, MIN. 30" HEADROOM CLEARANCE. 5 SELF-CLOSING & SELF-LATCHING SOLID CORE DOOR 1-3/8" THICK WITH 20 MINUTES RATED. (BY: CAL-DOOR CO. OR APPROVED EQUAL) 6 WATER HEATER & FURNACE SHOULD HAVE SEISMIC RESTRANT STRAP & ELEVATE PILOT HEIGHTS 18" MIN. ABOVE FLOOR, COVER WITH SHEET METAL. PER CPC & CMC. 7 BATH TUB AND SHOWER NOTES: 0 ALL INTERIOR FINISH MATERIALS, KITCHEN EQUIPMENTS, PLUMBING FIXTURES AND ELEC. FIXTURES SHALL BE SELECTED BY OWNERS. PROVIDE INTERCOM, SECURITY & VACUUM AT OWNER'S OPTION. 1 EXTERIOR WALL & PLUMBING WALL: 2x6 @ 16"o.c., TYP. 2 KITCHEN NOTES: FLOOR PLAN NOTES: # A. PROVIDE A SMOOTH FINISHED WALL w/ NONABSORBENT SURFACE UP TO 72" ABOVE THE DRAIN INLET B. TEMPERED GLASS ENCLOSURE C. PROVIDE FIBER-REINFORCED GYPSUM BACKERS (OR APPR. EQ.) D. ALL BATHTUB AND SHOWER SHOULD COMPLY WITH CRC R307.2 AND R702.4.2. TYP. E. PROVIDE W/R GREEN GYP. BD. @AROUND SHOWER, TUBS PER UBC CHAPTER 25 F. PROVIDE TEMPERED GLAZING WITHIN 60" FROM THE WET SURFACE OF TUB/SHOWER A. COOKTOP WITH EXHAUST AIR TO EXTERIOR WALL B. HOME CENTER WITH UPPER CABINET AND LIGHT C. DISH-WASHER, GARBAGE DISPOSAL, MICRO-WAVE, OVEN AND OTHER EQUIPMENTS SHALL BE SELECTED BY OWNER BEFORE CONSTRUCTION. D. PROVIDE GFCI PROTECTED OUTLETS AT COUNTER TOP. E. PROVIDE 2 MIN. SEPARATE 20 AMP CIRCUITS FOR SMALL KITCHEN APPLIANCES. FIRE SEPARATION BETWEEN HOUSE AND GARAGE: A. FIRE RATED MATERIALS (TYPICALLY 5/8" TYPE "X" GYP. BD.) ON THE GARGAGE SIDE OF THE WALL FROM FLOOR TO ROOF SHEATHING. THE 2ND FLOOR ATTIC ACCESS WILL REQUIRE FIRE PROTECTION SIMILAR TO 1ST FLOOR DOOR BETWEEN HOUSE/GARAGE. B. THE GARAGE CEILING WILL BE PART OF THE REQUIRED FIRE SEPARATION FRAMING PLANS SHOW 24" ON CENTER JOISTS REQUIRING ONE 5/8" TYPE "X" GYP. BD. ON 2X. ALTERNATE METHOD IS TWO LAYERS 5/8" TYPE "X" GYP. BD. OVER 24" ON CENTER JOISTS WITH GYP. BD. JOINTS STAGGERED AT LEAST ONE JOIST SPACING AT WALLBOARD EDGES AND ENDS. C. FOR CEILING AS PART OF THE FIRE SEPARATION, ALL WALLS, BEAMS, HEADERS, AND POSSIBLY POSTS ARE TO BE PROTECTED WITH FIRE RESISTIVE MATERIALS. D. ALL PIPING PENETRATIONS TO BE METAL, INCLUDING ANY PIPING EXPOSED ON GARAGE SIDE. E. DUCTS PENETRATING THE FIRE SEPARATION TO BE: 5.1 AT LEAST 26 GAUAGE GAVALNIZED STEEL (CRC R302.5.2) 5.2 CONTINUOUS FROM APPLIANCE THROUGH THE FIRE SEPARATION 5.3 NO OPENINGS TO THE GARAGE NOR NON METALLIC CONNECTIONS ALL EXTERIOR WINDOWS AND SLIDING DOORS SHALL BE TESTED BY AN APPROVED INDEPENDENT LABORATORY, AND BEAR A LABEL IDENTIFYING MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE WITH AAMA/WDMA/CSA 101/I.S.2/A440. EXTERIOR SIDE-HINGED DOORS SHALL BE TESTED AND LABELED AS CONFORMING TO AAMA/WDMA/CSA 101/I.S.2/A440 OR COMPLY WITH SECTION R609.1, R609.3 OR COMPLY WITH CRC R609.5. NOTES: 1. WINDOWS & DOOR SIZES ARE FOR DESIGN PURPOSED ONLY. ACTUAL WINDOW & DOOR SIZES SHALL BE FRAMED & SET PER MFG. SPECIFICATIONS. MAKE & MODEL NUMBERS SHALL BE CALLED OUT PER SUPPLIER'S AND/OR OWNER'S SPECIFICATIONS. WINDOWS TO BE DUALPLANED (U.N.O) 2. ALL GLASS DOORS, GLASS WITHIN 24" OF DOORS & WITHIN 18" OF FLOORS, GLASS SUBJECT TO HUMAN IMPACT ETC. SHALL BE SAFETY TEMPERED PER C.R.C. 308.4(2) 3. BEDROOM WINDOWS SHALL HAVE MAX 44" FROM FIN.FL. TO BOT. OF WDW OPEN'G & MIN. NET CLEAR OPEN'G OF 20" IN WIDTH & 24" IN HEIGHT w/MIN. CLEAR OPEN'G OF 5.7 S.F. PER C.R.C. 310 FOR EGRESS 4. WATER HEATERS & FURNACES TO BE C.E.C. CERTIFIED WATER HEATERS TO HAVE PRESSURE & TEMPERATURE RELIEF DEVICES & DISCHARGE TO OUTSIDE. 5. PROVIDE FIRE STOPS AN OPENING @ FLOOR & CEILING OF ALL FIREPLACES PER C.R.C. 302.11 6. WATER CLOSETS (TOILETS) SHALL USE NO MORE THAN 1.28 GALLONS/ FLUSH PER HEALTH & SAFETY CODE SECTION 179213(b) 7. PROVIDE AC/DC SMOKE DETECTORS WITHIN EACH SLEEPING ROOM & CENTRALLY LOCATED IN CORRIDORS OR AREAS GIVING ACCESS TO EACH SLEEPING AREA. ALL DETECTORS TO BE INTERCONNECTED TYPICAL. C.R.C. R314 8. NO UNDERFLOOR CLEANOUTS SHALL BE LOCATED MORE THAN 20' FROM THE ACCESS DOOR PER CPC 707.10, CBC 2306.3. 9. OPENINGS AROUND GAS VENTS, DUCTS & PIPING @ EACH FLOOR SHOULD BE FIRE STOPPED. 10. SHOWER & TUB-SHOWER COMB. SHALL BE PROVIDED w/ INDIVIDUAL CONTROL VALVES OF PRESSURE BALANCE HANDLE & ALSO COMPLY CRC R307.2 & R702.4.2, TYP. 11. SHOWER HEAD, SHALL NOT EXCEED 2.0 GPM AT 80 PSI. KITCHEN FAUCET SHALL NOT EXCEED 1.8 GPM AT 60 PSI & OTHER LAVATORY FAUCETS REQUIRED MAX. 1.5 GPM AT 60 PSI, MIN. 0.8 GPM AT 20 PSI. 12. ALL HOSE BIBS MUST BE PROTECTED BY AN ANTI SIPHON DEVICE, CPC 603.1. SHOWER VALVE SHALL HAVE ANTI-SCALD VALVE DEVICE. 13. GAS VENTS SHALL TERMINATE NOT LESS THAN 2' ABOVE THE HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF AND AT LEAST 2 FEET HIGHER THAN ANY PORTION OF A BUILDING WITHIN 10'. GAS VENTS SMALLER THAN 12" IN DIAMETER MAY TERMINATE AT LEAST 1' ABOVE THE ROOFS UP TO A 6:12 PITCH AND AT LEAST 8' FROM ANY PORTION OF THE BUILDING. FOR HIGHER ROOF PITCHES REFER TO FIGURE AND TABLE 802.6.2 CMC 802.6.2. 14. VENTS FOR FUEL BURNING APPLIANCES OTHER THAN DIRECT-VENT APPLIANCES SHALL TERMINATE AT LEAST 4' BELOW, 4' HORIZONTALLY FROM, OR 1' ABOVE ANY DOOR, OPERABLE WINDOW, OR GRAVITY AIR INLET INTO THE BUILDING. THE BOTTOM OF THE VENT SHALL BE LOCATED AT LEAST 12" ABOVE THE GRADE. CMC 802.8.2 15. ENVIRONMENTAL AIR DUCT EXHAUST; SUCH AS FOR KITCHEN RANGE EXHAUSTS, BATHROOM EXHAUSTS, AND CLOTHES DRYER EXHAUSTS, SHALL TERMINATE 3' FROM PROPERTY LIENS AND 3' FROM ANY OPENINGS INTO THE BUILDING. CMC 504.5 16. THE MINIMUM FINISHED INTERIOR AREA OF A SHOWER NEEDS TO BE AT LEAST 1024 SQUARE INCHES WITH A MINIMUM OF 30". THE SHOWER AREA AND DIMENSIONS SHALL BE MAINTAINED TO A POINT OF NOT LESS THAN 70" ABOVE THE DRAIN INLET. (CRC R307.2 & CPC 411.7) 17. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS AND VENTS SHALL TERMINATE NOT LESS THAN 10' FROM, OR LESS THAN 3' ABOVE, OR NOT LESS THAN 3' IN ANY CONDITION OF ANY CHIMNEY, PLUMBING VENTS, ALLEYS, STREETS, PARKING LOTS AND LOADING DOCKS. WHERE A SOURCE OF CONTAMINANT IS LOCATED WITHIN 10' OF AN INTAKE OPENING, SUCH OPENING SHALL BE LOCATED A MIN. OF 2' BELOW THE SOURCE. (CRC R 303.4.1. & CPC 906.2) 18. MIN. SLOPE OF SEWER LINE AND DRAINAGE PIPING IS 2% 19. ATTIC VENTILATION TO COMPLY CRC R505 20. CRAWL SPACE VENTILATION TO COMPLY CRC R317.7 21. PROVIDE FIRE BLOCKING IN CONCEALED SPACES 10' HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEYS AND FIREPLACES, CRC R302.11. 22. AN APPROVED BACKWATER VALVE IS REQUIRED FOR DRAINAGE PIPING SERVING FIXTURES LOCATED BELOW THE ELEVATION OF THE NEXT UPSTREAM MANHOLE COVER. FIXTURES ABOVE SUCH ELEVATION SHALL NOT DISCHARGE THRU. THE BACKWATER VALVE. CLEAN OUTS FOR DRAINS THAT PASS THRU. A BACKWATER VALVE SHALL BE CLEARLY IDENTIFIED w/ A PERMANENT LABEL STATING "BACKWATER VALVE DOWNSTREAM." 23. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR CLOSER THAT 18" OR WOOD GIRDERS CLOSER THAN 12" TO THE EXPOSED CRAWL SPACE SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY, CRC R 317.1(1). 24. FIELD-CUTTING ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. 25. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY, CRC R317.2(2). 26. TYPICAL ALL PLUMBING WALLS, BEARING WALLS AND WALL EXCEED 10'-0" HIGH SHALL BE 2x6 DF #2 STUDS @ 16" o.c. 27. ALL WALLS TO BE SMOOTH FINISH 28. CONTRACTOR TO INCLUDE ALL FINISH AND COLOR SPECIFIED BY OWNER AND INTERIOR DESIGNER. 29. ADD 3/8" CDZ PLYWOOD THOUGHT-OUT @ OUTSIDE FACE OF WALL. 30. CONTRACTOR TO INCLUDE INSULATION OF CLOSET ORGANIZER. (SELECTED BY OWNER) 31. CONTRACTOR TO VERIFY ALL OWNER'S APPLIANCE MANUAL SPEC. PRIOR TO CONSTRUCTION. 32. DESIGN BUILT CABINET TO FIT 33. CONTRACTOR TO VERIFY w/ OWNER'S INTERIOR DESIGNER FOR MATERIAL SELECTION AND COLOR PRIOR TO FINAL PRICING AND CONSTRUCTION. 34. ALL INTERIOR, DOOR, WINDOWS SIDE, HEAD AND SILL TO BE WOOD MOLDING. 35. GROUND ADJACENT TO THE FOUNDATION SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE FOUNDATION WALL. (2013 CEC E401.3) 36. INTERIOR SPACES INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH ACTIVE OR PASSIVE SPACE- HEATING SYSTEMS CAPABLE OF MAINTAINING A MIN. INDOOR TEMP. OF 68°F AT MIDWAY 3 FEET ABOVE THE FLOOR. R-2018-01 03/13/18 Ellen Yau DN DN INSULATED ATTIC 4 3' - 8 1/2"10' - 2 1/2" 2' - 5 1/2" 11' - 10 1/2" 3' - 3" 2' - 10"10' - 8"5' - 8 1/2" 9' - 9 3/4" 11 12 13 14 1516 17 24 22 23 1821 20 19 17 ATTIC ACCESS 7 18 15' - 0 1/2" 16' - 5 1/2"11' - 9 3/4" 14' - 4 1/2"26' - 2 1/4"31' - 6" 18 (N)BEDROOM 3(E)BEDROOM 2 (N)HALL (E)MASTER (N)W.I.C. (N)M.BATH (N)BATHROOM 1 A 3.1 3 A 3.1 REMOVE POPCORN CEILING 13' - 11" 2' - 5 1/2" 11' - 10 1/2"10' - 10 1/2"3' - 6" 11' - 9 3/4"10' - 8"15' - 6 1/4" 15' - 0 1/2" 12' - 10" 3' - 7 1/2" BEDROOM 2 BEDROOM 3 MASTER M.BATH BATHROOM 31' - 6"26' - 2 1/4"OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/4" = 1'-0" A 2.1PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103EXISTING/ PROPOSED 2ND FLOOR AND STREET VIEW 01/12/2018 1/4" = 1'-0"2 PROPOSED SECOND FLOOR 1/4" = 1'-0"1 EXISTING SECOND FLOOR EXISTING STREET VIEW P PROPOSED STREET VIEW 21391 MILFORD DR. 21371 MILFORD DR.21381 MILFORD DR. R-2018-01 03/13/18 Ellen Yau Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4"4" 12" 4" 12" 4" 12" 4" 12" 8" 12" 8" 12" E01 E05 E04 E03 E01 E05 E02 E08E08 25°PL PL 25°8" 12"10' - 0"10' - 0"Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4"4" 12" 4" 12"4" / 12"E01 E02 E03 E01 E05 E05 E05 E08 E05 FINISH FLOOR 0' - 6" Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4"4" / 12"4" 12" 4" 12" 8" / 12"4" 12" 4" 12" E01 E02 E03 E05E05 E01 FINISH FLOOR 0' - 6"3' - 10" 5' - 1 1/4"Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 4" 12" 4" 12"8" / 12"4" / 12" E01 E01E02 E03 E05E08E05 FINISH FLOOR 0' - 6"4' - 10"Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4"4" 1'-0" 4" 1'-0" 4" 1'-0" 4" 1'-0" 4" / 12"Level 1 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 4" / 1'-0"4" 12" 4" 12"4" / 1'-0"FINISH FLOOR 0' - 6" Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 4" 12" 4" 12"4" / 12"4" / 12"FINISH FLOOR 0' - 6" Level 1 0' - 0" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4"4" 12" 4" 12" FINISH FLOOR 0' - 6" OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/8" = 1'-0" A 3.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103PROPOSED ELEVATIONS 01/12/2018 1/8" = 1'-0"N PROPOSED FRONT/NORTH ELEVATION 1/8" = 1'-0" S PROPOSED REAR/SOUTH ELEVATION 1/8" = 1'-0"E PROPOSED SIDE/EAST ELEVATION 1/8" = 1'-0"W PROPOSED SIDE/WEST ELEVATION 1/8" = 1'-0"2 EXISTING FRONT/NORTH ELEVATION 1/8" = 1'-0"1 EXISTING SIDE/EAST ELEVATION 1/8" = 1'-0"3 EXISTING SIDE/WEST ELEVATION 1/8" = 1'-0"4 EXISTING REAR/SOUTH ELEVATION NOTE: CONTRACTOR SHALL OBTAIN THE APPROVED COLOR AND MATERIAL BOARD FROM THE OWNER BEFORE STARTING THE WORKS. ELEVATION NOTES: E01 ROOF: NEW COMPOSITION ROOF CLASS "A" 40 YEARS ON 2 LAYERS OF 30 LB BLDG FELT OVER PLYWOOD SHEATING. ROOF SLOPE SHALL BE 12:4 E02 5" 26 GA. G.I. PROFILE GUTTER ON 2X8 S4S SURFACE FASCIA BOARD WITH DOWNSPOUT AT PROPER LOCATIONS (ALL ROOF DRAINS SHALL BE DRAINED TO STREET DIRECTLY) E03 DOUBLE GLAZED "LOW -E" WINDOWS (TYP.) E04 CUSTOM SOLID CORE DOORS E05 3-COAT CEMENT PLASTER IN 17 GA. STUCCO NETTING ON 2 LAYERS GRADE 'D' BLDG PAPER. (WITH 26 GA. G.I. 'Z' FLASHING AT TOP EDGE OF BLDG PAPER). E08 WEEP SCREED (TYP.) ## R-2018-01 03/13/18 Ellen Yau 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 3 A 3.1 4 A 3.1 FINISH FLOOR 0' - 6" (N)STUDY(E)FAMILY RM(E)MASTER 4" 12" 4" 12" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 3 A 3.1 4 A 3.1 FINISH FLOOR 0' - 6" (N)LIVING RM (E)LIVING RM (N)KITCHEN 4" 12"4" 12" 4" 12" 4" 12" 1st FLR PLATE HT. 8' - 6" 2nd FLR PLATE HT. 17' - 4" RIDGE 22' - 4" 1 A 3.1 2 A 3.1 FINISH FLOOR 0' - 6" (N)BATHROOM (N)HALL (E)FAMILY RM (N)DINING (N)PANTRY (E) CEILING JOIST (E) FLOOR JOIST 4" 12" 4" 12" SKYLIGHT SKYLIGHT 1st FLR PLATE HT. 8' - 6" 2 A 3.1 FINISH FLOOR 0' - 6" (N)M.BATH (N)WIC (N)LIVING RM 8" 12" 8" 12" 8" 12"13" 12" 4" 12"9' - 3"8' - 3 3/4"16' - 11 3/4"16' - 0"3' - 1" 1 1 OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/4" = 1'-0" A 3.1PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103SECTIONS 01/12/2018 1/4" = 1'-0"1 Section 1 1/4" = 1'-0"2 Section 2 1/4" = 1'-0"3 Section 3 1/4" = 1'-0"4 Section 4 R-2018-01 03/13/18 Ellen Yau 4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" 4" / 12" 8" / 12"4" / 12"4" / 12"(E)(E)(E)(E) (E) (E) (N)(N)(N)(N)(E)(E)(N) (N) (N) (N) 13" / 12"(N)CRICKET (N)CRICKET 8" / 12"8" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12"4" / 12" 4" / 12"4" / 12"(E)(E)(E)(E) (E) (E)(E)(E)OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/8" = 1'-0" A 4.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103ROOF PLAN (NEW & EXISTING) 01/12/2018 1/8" = 1'-0"1 PROPOSED ROOF PLAN 1/8" = 1'-0"2 EXISTING ROOF PLAN R-2018-01 03/13/18 Ellen Yau 2#4 REBAR CONTINUOUS TO FTG (20'-0' LONG MIN.) CONDUIT ELEC. PANEL GYP. BD. STUCCO OR OTHER EXT. FINISH INTERIOREXTERIOR P.S.SILL PLATE W/ ANCHOR INSTALLED THE CULTURED STONE (ICC REPORT ESR-1364) OR APPR. EQ. NATURE GRADE OR CONC. PAVING DRIVEWAY 26 GA. NON-EROSIVE SHEET METAL SCREED BOLT RE: STRUCT. DRW'G MORTAR SCRATCH COAT GALVANIZED METAL LATH 2 LAYERS WATER RESIST. BARRIER PLYWD. SHEATHING W/ MORTAR JOINT EXTERIOR FINISH 3X OR 2X WD. STUDS (SEE STRUCT. FOR SIZE) GYP. BD.4"NOTE: ADHESIVE MATERIAL AND METHOD OR DESIGN SHALL COMPLY TO SEC. 6.1 AND 6.3 OF ACI530/ ASCE5/TMS403 OR RAISED FLOOR TYP. CONC. SLAB EXISTING PATIO TO REMAIN TYP. SEALANT SLOPE MIN. 1/4":1'-0" AWAY FROM STRUCTURE SEE DOOR SCHEDULE TYP. SLIDING DOOR TYP. 2X FORM TRIM OVER BLDG. PAPER 8" MIN. THRESHOLD HIGH CURB AT STUD WALL SEE DETAIL IN STRUCTURAL DWG. DOOR OGEE GUTTER & D.S. 26 GA. GALV. PRIMED & PAINTED COMPOSITION SHINGLE ROOF'G O/ 2 LAYER 30# FELT o/ STRUCTURE PLYWD. 1/2" PLYWOOD w/ RADIANT BARRIER PROVIDE ATTIC VENTILATION SCREEN VENTS PER 1/150 OF ATTIC AREA CALCULATIONS SEE A-2.0 ROOF-CEILING INSULATION 1/2" GYP. BOARD DOUBLE 2x4 PLATE WALL INSULATION 1/2" GYP. BOARD 3/8" THK. EXT.. STRUCT. PLYWD. STARTER STRIP ROOF TILE MORTAR 2 LAYER 30" FELT OVER PLYWOOD CDX G.I. FLASHING SIDING OVER BLDG PAPER SEE PLAN,TYP. OR STRAP SIMPSON HD PLYWOOD SHT'G SEE PLAN SHEAR WALL PROVIDE EDGE NAILING ALONG BOUNDARY LINES OF OPENING 2X OPENING SILL SHAPED FOAM W/ PLASTER COATING PRECAST OR APPROVED EQ. PRECAST OR FOAM BOARD APPROVED EQ. TRIM WALL PRECAST OR FOAM BOARD APPROVED EQ. WALL12"45°OPTION: 45° OF SLOPED CEILING 2x JOIST 2x4 2x4@24" 2x NAILER 1" VENTED AIRSPACE ALTERNATE WIND-RAIN BLOCK WHERE REQUIRED. HOLD 1/2" FROM HEAD END OF COMPOSITION SHINGLE INSULATION (TYP.) 1/2" PLYWOOD W/ RADIANT BARRIER 2 x RAFTER PLACE TOP OF LAST BATTEN 1 1/4" FROM CENTER OF RIDGE BOARD UNDERLAYMENT CARRIED OVER RIDGE NAILER CAP SHINGLE 1 2 "12" ROOT TILE O/ ONE LAYER 40# FELT o/ STRUCTURE PLYWD/ 30# FELT 26 GA. G.I, FLASHING PAINT TO MATCH ADJ. MATERIAL INSULATION (TYP.)1" VENTED AIRSPACE 1" V CRIMP 30# FELT 1/2" X NAILER 26 GA. G.I. FLASHING PAINT TO MATCH TILE ROOF SHINGLE O/ 2 LAYER 30# FELT o/ STRUCTURE PLYWD. NOTE: VALLEY FLASHING SHALL COMPLY WITH THE REQUIREMENTS OF CRC SEC. R905.2.8.2. SEMI-TRANSPARENT PLASTIC COVER 1/2" GYP BD TEXT & PAINTED NONREFLECTIVE FRAME) 2X6 CURB DBL 2X RAFTE RS (2) 2X6 2X6 CLG JSTS PER MFR. REQ'MENT 26 GA. GALV. FLASH'G 2X SKYLIGHT BY OR APPROVED EQ. (FLAT GLASS W/ANODIZED VELUIX (ICC Report ESR1004) NOTE: PLUMBING VENT TO BE MIN. 10FT AWAY FROM OR MIN. 3FT ABOVE ANY OPERABLE SKYLIGHT. PAPER @ STUCCO 2 LAYERS OF TREATED 2X4 (TREATED WOOD) (OR USE FOAM BOARD) 2X STUDS NOTE: ALL WOOD TO HAVE STUCCO W/ PAPER BACKED WIRE LATH TYPICAL GLASS 2X 2X4 @ 10° SLOPE (TREATED WOOD) BULL NOSE STUCCO MOLD 2X4 (OR USE FOAM BOARD) 2X4 2X STUDS GYP. BD. STUCCO W/ PAPER BACKED WIRE LATH G.I. BULL NOSE 2 LAYERS OF TREATED PAPER @ STUCCO LEDGER W/ PROVIDE 2X6 3-16d EA. IS NOT. STUD ONLY WHERE HDR (OR 2X10 CL'G JST) RAFTERS 2X10 R-38 INSULATION (CATHEDRAL BATT) 1" AIR SPACE BETWEEN RAFTER (1)-GALV. VENTS (SEE SHEET A1.0 FOR CALC.) EXPOSED BM. TO RECEIVE NOTCH HEADER FINISH 1/2" G.B. R.S.D.F. FALSE BM (OPTIONAL) TYPICAL GYP. BD. SEE TYP. 4X WINDOW HEADER (SEE STRUCT. DWG.) CORNER BEAD TYP. VINYL WINDOW TYP. 7/8" CEMENT PLASTER OVER PAPER BACKED LATH (2 LAYER GRADE "D" BLDG. PAPER) OR CEMENT BOARD SIDING OVER 30# FELT PAPER OVER 1/2" CDX PLYWOOD OR 3/8" CDX PLYWOOD SHEATHING PER SHEAR WALL OVER WOOD STUDS (TYP.) METAL FLASHING SEALANT @ ALL EDGES 2X FOAM TRIM TYP. 24 GA. G.S.M. FLASHING CAULK BEHIND NAIL FIN PRIOR TO INSTALLING WINDOW TYP. 7/8" CEMENT PLASTER OVER PAPER BACKED LATH (2 LAYER GRADE "D" BLDG. PAPER) OR CEMENT BOARD SIDING OVER 30# FELT PAPER OVER 1/2" CDX PLYWOOD OR 3/8" CDX PLYWOOD SHEATHING PER SHEAR WALL OVER WOOD STUDS (TYP.) 1X K.D. D.F. SILL BD. AND APRON METAL FLASHING TYP. 24 GA. G.S.M. FLASHING TYP. VINYL WINDOW CAULK BEHIND NAIL FIN PRIOR TO INSTALLING WINDOW SEALANT @ ALL EDGES OVER BLDG. PAPER TYP. 2X FORM TRIM INTERIOR WINDOW TRIM SEE DOOR SCHEDULE TYP. SLIDING DOOR WALL TYPE DETAILS TYPICAL GYP. BD. SEE SEALANT @ ALL EDGES CAULK BEHIND NAIL FIN PRIOR TO INSTALLING WINDOW OVER BLDG. PAPER TYP. 2X FORM TRIM TYP. 7/8" CEMENT PLASTER OVER PAPER BACKED LATH 26 GA. GALV. FLASH'G, PRIMED & PAINTED, COLOR TO MATCH ADJ. MATERIAL ONE LAYER 30# FELT 1'2" CDX. PLYWD. TYP. 2X4 FRAME TO FORM MIN. 2% SLOPE 7/8" STUCCO SOFFIT WITHOUT VENT WALL INSULATION 1/2" GYP. BOARD 7/8" STUCCO O/ PLYWD CLASS 'A' ROOF TILE O/ 2 LAYERS 30# BLDG PAPER O/ STRUCTURE PLYWD. HARDIE BOARD (@ FIRE RATED AREA) ROOF-CEILING INSULATION DOUBLE 2x4 PLATE 1/2" GYP. BOARD 1X1 NAILER METAL LATH OVER WATER BARRIER PAPER DENSGLASS SHEATHING DENSGLASS SHEATHING WATER RESISTANT BARRIER OVER METAL LATH OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT 1/4" = 1'-0" A 5.0PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103DETAILS 01/12/2018 N.T.S.18 'U'FER GROUND N.T.S.16 FINISH AND WEEP SCREED N.T.S.17 DOOR JAMB DETAIL N.T.S.19 DOORWAYS AT PATIO N.T.S.1 EAVE DETAIL N.T.S.6 FLASHING @ LOWER ROOF /WALL N.T.S.20 FOUNDATION VENT OPEN'G AT SHEARWALL N.T.S.15 PRECAST DECORATED SILL & TRIM (TYP.) N.T.S.9 RECESS CEILING N.T.S.2 RIDGE DETAIL N.T.S.7 ROOF VALLEY DETAIL 1 N.T.S.3 ROOF VALLEY DETAIL 2 N.T.S.4 SKYLIGHT DETAIL N.T.S.14 STUCCO SILL N.T.S.10 STUCCO TRIM N.T.S.5 VAULTED CEILING N.T.S.12 WINDOW DETAIL N.T.S.11 WINDOW DETAIL 1 N.T.S.13 WINDOW DETAIL 2 N.T.S.8 CRICKET 1/4" = 1'-0"21 1 HR FIRE RATED EAVE DETAIL R-2018-01 03/13/18 Ellen Yau R-2018-01 03/13/18 Ellen Yau OF SHEETS REVISIONS: SHEET TITLE: DRAWN: CHECKED: SCALE: JOB NO.: DATE: SHEET: 1 ARCHITECTURAL ENGINEERING CONSTRUCTION P.O. BOX 53892 SAN JOSE, CA 95153 TEL: 408 228-7526 FAX: 408 229-1688 ENGINEERING CONSULTING 02/01/18 PC COMMET FL CPT GB-1PROPOSED REMODELING AT21381 MILFORD DR.,CUPERTINO, CA 95014APN: 326-41-103GREEN BUILDING CHECKLIST 01/12/2018 CHEN & BAMBANG RESIDENCE 21381 MILFORD DR., CUPERTINO, CA 95014 ADD A TOTAL OF 696 SQ.FT. TO AN EXISTING 2,131 SQ.FT. TWO STORY SINGLE FAMILY DWELLING(NOT INCLUDING GARAGE OF 457 SQ.FT.) WITH NEW COVERED PORCH. AND REMODEL EXISITING 1,528 SQ.FT. JOHN CHEN & IMELDA BAMBANG CLARA TING CLARA TING ACLARAENG@GMAIL.COM 408.228.7526 CHEN & BAMBANG RESIDENCE 21381 MILFORD DR., CUPERTINO, CA 95014 ADD A TOTAL OF 696 SQ.FT. TO AN EXISTING 2,131 SQ.FT. TWO STORY SINGLE FAMILY DWELLING(NOT INCLUDING GARAGE OF 457 SQ.FT.) WITH NEW COVERED PORCH. AND REMODEL EXISITING 1,528 SQ.FT. R-2018-01 03/13/18 Ellen Yau R-2018-01 03/13/18 Ellen Yau