Loading...
14100167 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19390 CALLS DE BARCELONA CONTRACTOR:FIDELITY HOME PERMIT NO: 14100167 ENERGY INC OWNER'S NAME: KATHERINE CHU 8445 CAMINO SANTA FE STE 104 DATE ISSUED: 10/28/2014 OWNER'S PHONE: 4089962507 SAN DIEGO,CA 92121 PHONE NO:(858)457-4500 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL G --7 INSTALL 8 ROOF TOP,FLUSH MOUNTED PV PANELS,2.2 License Class 35 TD Lic.4 -1 / KW Contractor Date 106 � I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$12000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this ANN Number:37505009.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 D CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will co 3 with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date 2 ` All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,Owner or authorized agent: /25533, Section 3700 of the Labor Code,for the performance of the work for which this /% Q 1y permit is issued. Date: I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,[ CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION ADDRESS: 19390 CALLE DE BARCELONA DATE: 10/28/2014 REVIEWED BY: MELISSA APN: 355 05 009 BP#: 'VALUATION: 1$12,000 '-PERMIT TYPE: Building Permit PLAN CHECK TYP Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: wORK INSTALL 8 ROOF TOP FLUSH MOUNTED PV PANELS 2.2 kW SCOPE NOTE: This estimate does not include fees due to other Departments(ie. Planning,Public Works,Fire,Sanitary Sewer District,School District, etc). Thesefees are based on the preliminar information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/V13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: Q Reg. Q OT0.0 hrs $0.00 $236.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 ( nrt.,trt cti��ta Tcjx- .4,11ninwrwitic Fee: Work Without Permit? 0 Yes 0 No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential G Travel 1)(waincalation Fcc.s. Building or Structure 0 i Strom Motion Fee: IBSEISMICR $1.56 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 SUBTOTALS: $2.56 $236.00 TOTAL FEE: $238.56 Revised: 08/20/2014 ALTERNATIVE ENERGY PERMIT APPLICATION �( 10 COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 V� (408)777-3228 • FAX(408)777-3333 • building(d)cupertino.orq a CUPERTINO \ PROJECT ADDRESS 199)90 C 1 APN N OWNER NAME ) r�Q STREET ADDR Sq �F�C �Q�C�f14 t CITY'S1TATE,ZI)� i FAX � a CONTACT NAME - - F _�� E-MAIL Ma STREET ADDRESS CITY,STATE, ZIP FAX ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONrFACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME t LICE NSE NUMBER LICENSE TYPE C Y(0 BUS.LIC k 2�'� t eNd 01 ca, C3 ,c3q COMPANY NAME ^ t ` E-MAIL FAX STREET ADDRESS r C TY,STATE,ZIP PHO CLA ARCHITECT/ENGrNEER NAME i LICENSE NUMBER BUS.LIC d _1 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT M STRUCTURE: ❑ Commercial URBAN INTERFACE AREA Cl Yes VLNO FLOOD ZONE ❑ Yes �6 No N9ta-01-AR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION 1 ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS UNITS: Q KILOWATTS(COMMERCIAL ONLY): `�7 TOTAL VAL TI iVr /2!00 DESCRIPTION L WORK — a� V cS' Z.2 k �_ECEI �owne�'sl By my signature below,I certify to each of the following: 1 am the property owner or authorized agent to act on the prothis application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to building onstruction. I aut r' e rept e hof Cupertino to enter the abooyvve�e-1 entified property for inspection purposes. Signature ofApplicanUAgent Date; �V�2�/1 SUPPLEMENTAL rNTFORMATION REQUIRED OFFICE USE ONLY ca ❑ OVER-TAF COUNTER F ❑ EXPRESS U ❑ STANDARD. . U Z a. ❑ LARGE c. ❑ MAJOR .. PVApp_201 I.doc revised 03/16/11 Sunmodul 7P-' 1U­_s1 .SW 2 mono CUPERTINO suilding Department AOCT 28 2014 ower controlled: Reviewed BY: Every component is tested to meet 3 times IEC requirements Designed to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance tolerance 25-year linear performance warranty and 10-year product warranty V World-class quality 314ty-d.IEC 61M Fully-automated production lines and seamless monitoring of the process and materialDVE ensure the quality that the company sets as its benchmark for its sites worldwide. a1°'"°'°°°'" 1—,—d 12,- p-C,-1W SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules that G SP® us have greaterthan or equal to the nameplate rated power. UL 1703 25 years linear performance guarantee and extension of product warranty to 10 yearsIS0900401 IS0101 SolarWorld guarantees a maximum performance degression of 0.7%p.a.in the course of LLI L Certified -A 25years,a significant added value compared to the two-phase warranties common in the industry.In addition,SolarWorld isoffering a product warranty,which has been extended tolOyears.* 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty SOLARWORLD MADE IN USA \1.11� solarworld.com We turn sunlight into power. Sunmodule;I'lPlusSW275mono PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' PERFORMANCE AT 800 W/m',NOCT,AM 1.5 Maximum power P 275 Wp Maximum power P 205.0 Wp Open circuit voltage V- 39.4 V Open circuit voltage V.- 36.1 V Maximum power point voltage V 31.0 V Maximum power point voltage V 28.4 V Short circuit current 1 mo 9.58 A Short circuit current Imo 7.75 A Maximum power point current 1— 8.94 A Maximum power point current 7.22 A 'STC,1000 W/m',25'C,AM 1.5 Minor reduction in efficiency under partial load conditions at 25°C:at 200 W/m',100% 1)Measuring tolerance(Pi..)traceable toTUVRheinland:+/-2%(TUVPower Controlled). (+/-2%)of the STC efficiency(1000W/m2)isachieved. COMPONENT MATERIALS THERMAL CHARACTERISTICS Cells per module 60 NOCT 46'C Cell type Mono crystalline TCI 0.004%/K Cell dimensions 6.14 in x 6.14 in(156 mm x 156 mm) TCv. -0.30%/K Front Tempered glass(EN 12150) TCP -0.45%/K Frame Clear anodized aluminum Operating temperature -40'C to 85°C Weight 46.7 lbs(21.2 kg) SYSTEM INTEGRATION PARAMETERS 1000 W/m1 qtr Maximum system voltage SC 11 1000 V Max.system voltage USA NEC 600 V 800 W/m' Maximum reverse current 16 A Number of bypass diodes 3 a 600 W/m' 113 psf downward UL Design Loads' Two rail system 64 psf upward 400 W/m' 170 psf downward oUL Design Loads' Three rail system 64 psf upward 200 W/ml113 psf downward _ IECDesign Loads' Two rail system 50 psf upward 100 W/m2 'Please refer;o the Sunmodule installation instructions for the details associated with `' these load cases. Module voltage IV] v u ADDITIONAL DATA X4 37.4A(951) Power sorting' O W p/+5 wp � J-Box I P65 Connector MC4 11.33(288) Module efficiency 16.40% Fire rating(UL 790) Class C 0.6 15.3 41.30(1050) 4 VERSION 2.5 FRAME Compatible with both"Top-Down" Version and"Bottom"mounting methods zs frame v6 Grounding Locations: 65.94(1675) bottom -4 corners of the frame mounting 4 locations alongthe length of the holes module in the extended flangef 1.34 34 —� x4 G W1 Independently created PAN files now available. Ask our account manager for more information. 4.20(107) your (31) F�39.41(1001) - All units provided are imperial.SI units provided In parentheses. SolarWorld AG reserves the right to make specification changes without notice. SW-01-6005US 08-2013 0A h, APS Leading the industry in MICROINVERTER Hl -ro[�'-iverter Te"x.71 ology YC500A Microinverter DIMENSIONS 90.1"(2290mm) 8.7"(221mm) Our flagship product, the APS YC500A is a grid-tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. Highly dependable and cost effective, the YC500A handles up to 31OW ® modules with negligible clipping, delivering 250W AC per 6.5"(167mm) module with dual MPPT. Half the inverters and half the E=_1 installation means real cost savings for residential and commercial customers. l i APSamerica•com INPUT DATA (DC) Recommended PV Module Power Range(STC) 180-310W MPPT Voltage Range 22-45V Maximum Input Voltage 55V Maximum Input Current 12A X 2 OUTPUT DATA (AC) Rated Output Power 50OW Maximum Output Current 2.08A @ 240V 2.4A @208V Nominal Output Voltage/Range-240V 240V/211V-264V- Nominal Output Voltage/Range- 208V 208V/183V-229V` Nominal Output Frequency/Range 60Hz/ 59.3-60.SHzt Power Factor >0.99 Total Harmonic Distortion <3% Maximum Units Per Branch 7 per 20A @ 240V 6 per 20A @ 208V EFFICIENCY Peak Efficiency 95.5% CEC Weighted Efficiency 95% Nominal MPP Tracking Efficiency 99.5% MECHANICAL DATA Storage Temperature Range -40°F to +185°F(-40°C to +85°C) Operating Temperature Range(Ambient) -40°F to +149°F (-40°C to +65°C) Operating Temperature Range(Internal) -40°F to +185°F(-40°C to +85°C) Dimensions (WxHxD) inches 8.75" x 6.5" x 1.1" Dimensions (WxHxD) mm 221mm x 167mm x 29mm Weight 5.5 lbs(2.5kg) Enclosure Rating NEMA 4X Cooling Natural Convection FEATURES & COMPLIANCE Communication Power line Design Life 25 years Emissions & Immunity (EMC)Compliance FCC PART 15, ANSI C63.4 2003, ICES-003 Safety Class Compliance UL 1741,CSA C22.2, No.107.1-01, NEC2014 690.12 Grid Connection Compliance IEEE 1547 Specifications subject to change without notice-please ensure you are using the Programmable per customer and utility requirements. most recent update found at www.APSamerica.com All settings UL approved 6.2.14©All Rights Reserved 2025 Hostmark St.,Suite 204, Poulsbo,WA 98370 j 844.666.7035 APSamerica.com APS MICROINVERTER • DUALRACK Installation Optionl.a Installation Option l.b Installation Option 2 0 0 0 RAIL RAIL Material Specifications: 3/8-16x3/4" 3/8-16x3/4" HEX BOLT HEX BOLT Material Designation 6005-T5 3/8-16 FLANG NUT 3/8-16 FLANG NUT RAIL Density(p) 168.56 lb/f:(2.7 g/cm) Coefficient Of Thermal Expansion(a,.) 1306E-05/°F(2.35E-05/°C) U FOOT L-FOOT s V HEX BOLT Diffusivity 200.00 W/m-°K ❑ ❑ Modulus ofelelasticiry(E) 10.152E06 Psi(7,000 kN/cm') Shear Modulus(G) 3.916E06 Psi(2,700 kN/cm') LB"HEX BOLT Mechanical Properties: Tensile Strength(f,.) 38.0 Ksi(26.0 kN/cm') TANDO STAND OFF Tensile Yield Strength(f,,) 35.0 Ksi(24.0 kN/cm') AG BOL :i,5',6'or T LAG BOLT Profile Wall Thickness (I<_0.39 in/10 mm) ROOF RAFTE 3'.5'.6'or 7' Section Properties: ROOF RAFTER 1, 3.721 id(9.450 cm") W 1.859 in'(4.720 cm') 1, 6.391 in'(16.230 cm') W 2.626 in(6.670 cm') A 0.629 in2(4.060 cm2) Weight 0.737 Ib,/ft(1.10kg/m) Length: 144"/168" Rail Spans (ft):• L-FOOT e DESIGN WIND SPEED(mph) 80 90 100 110 120 130 140 150 SNOW LOAD(pso RAIL SIZE RAIL SIZE RAIL SIZE RAIL SIZE RAIL SIZE RAIL SIZE RAIL SIZE RAIL SIZE 13/58 13/58 13/58 13/58 13/58 13/58 13/58 13/58 0 6 6 6 6 6 4 4 4 10 6 6 6 6 4 4 4 4 20 6 6 6 6 4 4 4 4 60MM 30 6 4 4 4 4 4 4 4 2. 62' 40 4 4 4 4 4 4 4 4 50 4 4 4 4 4 4 4 4 I.Rail spans assume 24"rafter spacing and are shown to the farthest acceptable rafter;Parameters:Gable roof<15'high,slope<25°,850'AMSL, Occupancy Category 11(importance factor=1.0),Terrain category B,Partially exposed,center zone installation."NS=Not Suitable". lOMM 2.Calculations assume stand-alone L-foot or L-foot mounted to Quick Mount PV AMSC mount/flashing. 0,394' �— PRODUCT CATEGORY_ RAIL _ DESIGNED BY FORTUNE ENERGY INC. FORTUNE ENERGY INC. ; �4D M_� DRAWING INITIAL RELEASE DATE 04/75/2073 21029 1TA5CA ST. BOLDING A-B 1,575• NOTICE: DO NOT SCALE DRAWING CHATSWORTH, CA 9131 1 OFFICE: .(818) 678-9699 Fir - ne Energy PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED IN THIS WEB: WWWFORTUNEENERGY.NET DRAWING IS THE SOLE PROPERTY OF FORTUNE ENERGY INC.ANY REPRODUCTION IN PART OR ASA WHOLE WITHOUT THE WRITTEN PERMISSION FROM FORTUNE ATENT PENDING ENERGY INC IS PROHIBITED. Tile Roof Hook Universal Mount Installation Manual mm Pub 130814-1 ■■ N U N I RAC A HILTI GROUP COMPANY Unirac welcomes input concerning the accuracy and user-friendliness of this publication.Please write to publications@unirae.eom. Tile Hook Roof Universal Mount Installation Manual Step 1: Attach roof hooks to the rafters • Remove or slide up the roof tile • Position the roof hook above the roof rafter(for high roof rafters,shim if necessary) • Place Tile Hook in the middle of the underlying interlocking tile's valley. • Drill 3/16 inch pilot holes through the underlayment into the center of the rafters.Securely fasten each tile hook to the rafters with two 5/16"x 3%:"lag screws.(if spacer boards are used,lag bolts may need to be replaced with longer ones.For proper embedment,refer to Table 2 [page 3]for lag bolt pull out values).(Fig 2) •Slide down or re-insert the tile •S i Figure I Figure 2 Step 2: Attach L Foot to tile roof hook(Fig 3) Tile Hook Components: I tile hook I stainless steel bolt i, I nut Figure 3 Pn 2 Tile Hook Roof Universal Mount Installation Manual Table I .Tile Hook Spacing Chart Snow Load 0 5 10 15 20 25 30 35 40 Basic Wind Speed 85 mph 54" 54" 47" 40" 35" 31" 28" 26" 23" 90 mph 48" 48" 44" 38" 33" 30" 27" 25" 23" 110 mph 31" 31" 31" 31" 28" 25" 23" 21" 20" 120 mph 26" 26" 26" 26" 25" 23" 21" 20" 19" 150 mph 16" 16" 16" 16" 16" 16" 16" 16" 15" The table above is subject to the limitations listed below. It is intended as a quick reference guide based on the most common configurations. Please refer to load tables on pages 5,6 and 7 for design loads. Engineering Guide Limitations • Flush roof installations only Please refer to Technical Support for more • Roof slope must be 0-45 degrees (0/12- 12/12 pitch) information on roof zones • Installation must have at least 4 modules grouped Span for Roof Zone 2= 1/2 max span together Span for Roof Zone 3= 1/3 max span • Module dimensions must be less than 42"x65" Max Cantilever= 1/3 max span • Surrounding ground area must not slope more than 10 degrees Please refer to Unirac Technical Support for installations that • Location must fall into Exposure Category B or C do not comply with the limitations above. • Building height must be less than or equal to 30'0" Table 2. Lag pull-out (withdrawal) capacities (lbs) in typical roof lumber (ASD) Specific Lag screw specifications Gravity5/16"shaft," Use Table 2 to select a lag bolt embedment per inch thread depth depth to satisfy your Uplift Point Load Force Douglas Fir,Larch 0.50 266 (lbs),requirements. Douglas Fir,South 0.46 235 Engelmann Spruce,Lodgepole Pine(MSR 1650 f&higher) 0.46 235 It is the installer's responsibility to verify that the substructure and attachment Hem,Fir,Redwood(Close Grain) 0.43 212 method is strong enough to support the Southern Pine 0.55 307 maximum point loads calculated. Spruce,Pine,Fir 0.42 205 Spruce,Pine,Fir(E of 2 million psi& 0.50 266 higher grades of MSR&MEL) Sources:American Wood Council,NDS 2005,Table I Notes: (I)Thread most be embedded in the side grain of a rafter or other structural member intergral with the building structure. (2)Lag bolts must be located in the middle third of the structural member. (3)These values are not valid for wet service. (4)This table does not include shear capacities.If necessary,contact a local engineer to specify lag bolt size with regard to shear forces. (5)Install lag bolts with head and washer flush to surface(no gap).Do not over-torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. See table 10.3 in the American Wood Council NDS for Woad Construction 3 Tile Hook Roof Universal Mount Installation 11anual Tile Modifications that may be required: How do I make modifications on tile retaining lip profiles that interfere with the tile resting flat against the tile hook (figure 4)? Tile retaining lip removal may be needed to allow for clearance of the hook. To do so,there are two options: Option A (figure 5):Use a hammer to remove the lip or obstruction. Option B (figure 6):Using a grinder,remove the lip or obstruction. Figure 4 z' Figure S Figure 6 How do I adjust upper and lower tile profiles that do G�. not allow the the to rest flat above the hook? In some cases,the upper or lower tile may need to be modified;follow these steps for either situation(for illustrative purposes,we'll show the upper tile modification) Figure 7 Step I (figure 7) Using rolled aluminum or »; sheet metal flashing,cut enough material to fit the exposed area. f y. Step 2 (figure 8) Modify the tile with a slot to allow for the tile hook to pass Figure 8 through. (Aa Step 3 (figure 9) Insert the cut flashing under •+"' the tile hook base and over the lower tile. Complete the tile hook installation as described on page 2. Figure 9 4 Tile Hook Roof Universal Mount Installation Manual Standard C Shaped Top Mounting Hook Allowable Loading Allowable Load (lbsl (1.9 Safety Facforl Downforce 236 Uplift 191 Shear 214 7/16 x 1-9/16" slot thru 2-3/8" Uplift shear 7/16 x 1-5/16" 7/16" slot thru thru downforce 4-1/2" I-13/16" 1-7/8" 7-1/8" 2-13/16" P", 5 .�i ewe . � r44 PANELS.' 's Silo J SO LARWORLD 275W r�t��E'f - °n1 :. QTY.• 8 of C3 r0 pe�.�, '-.an a PROPOSED 2,2 KW GRID TIED PHOTOVOLTAIC SYSTEM INVERTER INVERTER TYPE. RMT# ��°e or SraVIO1atlon APS YC500A CLIENT: CHU o y MICRO INVERTERS QTY: 4 --- ADDRESS: 19390 CALLS DE BARCELONA, CUPERTINO, CA 95014 CPR Tr140 MOUNTING SYSTEM: bulidin9 De partrnent Oil DUAL RACK PHONE: 408-996-2507 +1c`✓IEI��D rUR ,;00E COMPLIANCE By, 10B # HEC1945 ROOF TYPE: REcEj��� Applicable codes& regulations: _ PLOT PLANS j � COMPOSITION 2014 CHECKED BY California Building Code 2013 Edition DATE I a PITCH: 20 California Residential Code 2013 Edition �� _ !� AZIMUTH: 180 California Fire Code 2013 Edition `AINN NG DEPT. PANEL UPGRADE: California Mechanical Code 2013 Edition California Electric Code 2013 Edition 125A California EnergyCode December Edition j'►��— r` ~— type of Construction CBC 602.5& Table 601 V-B CAB,LIC 790709 occupancy Group CBC 301.1 &312.1 R3& U 5 MXNO AIIN�A1 COPY FIDELITY HOME ENERGY Client CHU PANELS. INVERTER TYPE. MOUNTING SYSTEM. ROOF TYPE. ROOF PITCH. Fidelity Energy Address: 19390 CALLE DE BARCELONA SOLARWORLD 275W APS YC500A MICRO INVERTERS DUAL RACK COMPOSITION 20 City: CUPERTINO, CA 95014 Qom" 8 QT-Y.• 4 ROOF CONDITION: GOOD Phone: 408-996-2507 MODULES RUN IN: PANEL UPGRADE.- MOUNTING STYLE., HOME ELEVATION: ROOFAZIMUTH. JOB #: HEC1945 SERIES 125A FLUSH WITH ROOF SINGLE STORY 180 FIRE LADDER ACCESS POINT FRONT O F HOME r✓UPERT E10 • Pin Building Department 'SETBACKS OCT Z 8 2014 3'FROMRIDGE I8"FROM kEVIEWED FOR CODE CO%iPLIRNCE HIP OR VALLEY 8 SW275 PANELS W/ 4 APSS00 MICROINVERTWiewea By Ja-s" • FL USH MOUNTED ON 20 DEGREE PITCHED ROOF WITH AN ORIENTATION OF 180 DEGREES AZIMUTH 3' DUAL RACK RAILS AND FLASH L KITS • SUPPORTS AT 24"MAX FROM EDGE ' OF PANELS PENETRATIONS WITH 5/16 S.S.BOLTS • _ MINNIMUM EMBEDDMENT 2-112" S S s AND 48"MAX. 0.C, RAILS BONDED WnN GROUND LUGS AND 08 BARE COPPER LBW 2"X 4"RAFTERS-24"O/C MAX SPAN-5' ' S1 NEW 125A MAIN I 2X4 RAFTERS 24"0.C. ALL ROOF PATCHING WILL BE KW.'2.2 ' v MADE WITH THE SAME MATERIAL POINT LOAD: 1THA T CURRENTL Y EXISTS • 22.47 LBS PER FOOTING E ALL CONDUIT,JUNCTION BOXES AND LOAD VENT-NO VENTS OF ANYKIND PV MODULES LABELED AND INSTALLED IN Z48 LBS PER SQUARE FEET PER PANEL COVERED 8Y PROPOSED ARRAY ACCORDANCE WITH CEC CODES S PAGE 2OF6 FIDELITY HOME ENERGY Client CHU PANELS: INVERTER TYPE. MOUNTING SYSTEM: ROOF TYPE. ROOF PITCH: Fidelity Energy Address: 19390 CALLS DE BARCELONA SOLARWORLD 275W APS YCSWA MICRO INVERTERS DUAL RACK COMPOSITION 20 ,4 City: CUPERTINO, CA 95014 QTY,• 8 QTY,- 4 ROOF CONDITION: GOOD Phone: 408-996-2507 MODULES RUN IN: PANEL UPGRADE: MOUNTING STYLE.• HOME ELEVATION: ROOFAZIMUTH. JOB #: HEC1945 SERIES 125A FLUSH WITH ROOF SINGLE STORY 180 i1c Building DeWtMe►t+ ALL CONDUCTORS IN CONDUIT 8SOLARWORLD 275WPANELS W/4APS YC500 MICROMVERTERS �,T • ON THE EXTERIOR OF THE 0�� 1 � Z01� • BUILDING SHALL BE WET RATED. NEMA3 REViEOJ U -r--OR CODE COMPLIANCE USE-2-10 AWG G JUNCTION BOX THWN-2-10 AWG lit ev i ew ed 9,y jam'^- '�` ACTUAL PHOTOS PROVIDED 1 0 1 IN SEPARATE SHEET IF REQUIRED BY CITY/COUNTY ,#8AWG ALL CONDUIT SHALL BE PAINTED BARE COPPER I TO MA TCH SURFACE OF BUILDING WITH CW770N • I LABELS @a 10'IN7ERVAL5 .I_ . J . _I- - - - - - #8AWGGROUND ALL WIRE EXPOSED ON ROOF LINKING PV PANELS TOGETHER MAIN DISCONNECT I TO BE USE/THWN-2 owRATED WIRE. 30A SAFETY DISCONNECT NEW I 125A SQUARED MAIN ALL WIRE TO BE RUN IN EMT I 240VAC, 125A W120A 2-POLE CONDUIT 314" FOR POINT OF CONNECTION CO O ALL CONDUITS TO BE#8 BARE GROUNDING THWN-2-10 AWG j NEC 208 20A TWO POLE BREAKER 0 LABELS LEGENDS nv Grounding ROD OO POINT OF CONNECTION PAGE 4. CONNECTED W1#6AWG FOR PHOTOVOLTAIC SYSTEM PAGE 3OF6 FIDELITY HOME ENERGY Client CHU PANELS; INVERTER TYPE; MOUNTING SYSTEM: ROOF TYPE; ROOF PITCH: 4 Fide1ity .,. :Energy Address: 19390 CALLE DE BARCELONA SOLAR{NORLD 275W APS YC500A MICRO INVERTERS DUAL RACK COMPOSITION 20 City: CUPERTINO, CA 95014 QTY" 8 QTY.• 4 ROOF CONDITION: GOOD Phone: 408-996-2507 MODULES RUN IN; PANEL UPGRADE; MOUNTING STYLE. HOME ELEVATION; ROOFAZIMUTH; )OB #: HEC1945 SERIES 125A FLUSH WITH ROOF SINGLE STORY 180 PV MODULERA77NGS CONTENT: CAUTION - SOLAR ELECTRIC SYSTEM BACKGROUND: RED MODULEMAKE SOLARWORLD LETTERING: WHITE MODULE SW 275 ALL CAPITAL LETTERS MAX POWER POINT CURRENT(Imp) 8.94A MINIMUM HEIGHT: 1-1/2" MAX POWER VOLTAGE(Vmp) 31 V FONT: ARIAL OR SIMILAR NON-BOLD OPEN CIRCUIT VOL TAGE(Vo C) 39.4V REFLECTIVE SURFACE AND MATERIAL SUITABLE FOR SHORT CIRCUIT CURRENT(Isc) 9.58A EXTERIOR USE MAX SERIES FUSE(OCDP) 20A MAX POWER(Pmax) 275W LOCATION: MAX VOLTAGE-DC 1000V ALL INTERIOR AND EXTERIOR CON DUIT,RACEWAYS, VOC TEMP COEFFICIENT -0.3096/C ENCLOSURES AND CABLE ASSEMBLYS. EVERY 10' AT ALL TURNS, ABOVE AND BELOW ALL PENETRATIONS, AT ALL DC COMBINER AND INVERTER RATINGS JUNCTION BOXES. INVERTER NAME APSAMERICA CONDUIT,WIRING,AND RACEWAYS WILL BE INVERTER MODEL YC500A MICROINVERTER MOUNTED AS CLOSE AS POSSIBLE TO THE RIDGE, MAX DC VOLT RATING 55V HIP, OR VALLEY TO REDUCE TRIP HAZARDS AND MAX POWER SOOW MAXIMIZE VENTILATION OPPORTUNITIES � ��� ....I CUPERTINO 6uildirtg Departinenr jr NOMINAL AC VOLTAGE 240 V _ MAX AC CURRENT 8.32A MAX OCPD RATING 20A F2 '"s`VIEOjED FOR CURE COM.PL_ IA!Vt,;r Meviewed 6y PAGE 4 OF 6 FIDELITY HOME ENERGY Client CHU PANELS: INVERTER TYPE: MOUNTING SYSTEM: ROOF TYPE: ROOFPITCH: Fidelity -'.;Energy Address: 19390 CALLS DE BARCELONA SOLARWORLD 275W APS YC500A MICRO INVERTERS DUAL RACK COMPOSITION 20 City: CUPERTINO, CA 95014 QTY: 8 QTY.- 4 ROOF CONDITION: GOOD Phone: 408-996-2507 MODULES RUN IN. PANEL UPGRADE: MOUNTINGSTYM HOME ELEVATION: ROOFAZIMUTH: ]OB #: HEC1945 SERIES 125A FLUSH WITH ROOF SINGLE STORY 180 • LABELS O PER CEC 690-SMCO-SEC 9116 RACEWAYS EVERY 10' AC DISCONNECT- CAUTION ISCONNECTCAUTION SOLAR PHOTOVOLTAIC SYSTEM AC A CIRCUIT E DISCONNECT: RATED AC OUTPUT CURRENT: AMPS NOMINAL OPERATING AC VOLTAGE: 240VOLTS FA DERESISTANTDICONNECTLABEL MAIN SERVICE PANEL EMERGENCY DISCONNECT D WARNING TWO POWER AC DISCONNECT WARNING: SOURCES PHOTOVOLTAIC ELECTRIC SHOCK HAZARD DO NOT B DISCONNECT LOCATED AT TOUCH TERMINALS. TERMINALS ON LEFT SIDE OF THE HOUSE F BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PERMANENT PLACARD-EXTERIOR/INTERIOR OF MAIN CAUTION SOLAR PV SYSTEM INSTALLED. WHEN H DO NOT RELOCATE C POWER IS DISCONNECTED, SOLAR PANELS AND ALL SOLAR CONDUITS, INTERIOR/EXTERIOR WIRING MAY REMAIN ENERGIZED DURING CAUTION: SOLAR PV WIRING MAY DAYLIGHT HOURS REMAIN ENERGIZED AFTER -1 <'U�F�TINU G P�4, : , DISCONNECT DURING DAYLIGHT I a' f3uiiding department HOURS k 8 2014 r,EV1EA-E11 FGR CGDE COMPLIANCE Reviewed Br PAGE 5OF6 FIDELITY HOME ENERGY Client CHU PANELS. INVERTER TYPE., MOUNTING SYSTEM. ROOF TYPE.• ROOF PITCH. Fidelity' :Energy Address: 19390 CALLE DE BARCELONA. SOLARWORLD 275W APS YC500A MICRO INVERTERS DUAL RACK COMPOSITION 20 City: CUPERTINO, CA 95014 QTY,• 8 QTY.- 4 ROOF CONDITION., GOOD Phone: 408-996-2507 MODULES RUN IN. PANEL UPGRADE. MOUNTING STYLE., HOME ELEVATION; ROOFAZIMUTH; ]OB #: HEC1945 SERIES 125A FLUSH WITH ROOF SINGLE STORY 180 SEE DETAILS AND SUPPORTING DOCUMENTS - IL SCO MODULE GROUND LUG (SEPARATE CUT SHEETS ARE PROVIDED W1 THE RESUBMITTALS) S.S. 10-32X1/2 BOLTS AND KNOTS —20 IN-LBS COPPER WIRE #8 AT 20 IN-LBS fi�wficri=ifxi�� I,ee l�r��i „x c �ttrar; �`.I'a . lr�s+�►tPr,rr,ra t.�r�►,�I ) �eg.4 i8,♦'++t?k1,T � !E s;S+i:tt+71��'G d�il. NUTS TO BE TORQUED @ 10 FT.LB. t�_�•sem r. //end clamp T mid clamp + l module r module BOL TS 5° 3Ii' FORTUNE ENERGY I . . .. . . . PEkTtNo Cu F�'ui+ a l �ttrxa ,' � ► t. ding Depa►t,. W.M 1!., 17 }. *il wd +NII _ �'Nxtti6'i nAir Tfn )f X11 jft k�ii -}2f i�>i£§t1�L Jt�IE X73!1 It+1Ki '.I f 1T4� C1?-F R sif 4f7A Kii uI ` r _k }syn s.� ��� s ase }t�� _i{.� t�,a� It'v� t:f✓ ir,!arEl �(�P. t�01Ll ds � a � R f s a `� evtewed By .. 3 d �`1.9n ayt PAGE6OF6