Loading...
14110010 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 11441 S STELLING RD CONTRACTOR:SUN WORK PERM IT NO: 14110010 RENEWABLE ENERGY PROJECTS OWNER'S NAME: RAMESH SUNIL AND MURGUDE MANISHA 477 VALLEY WAY DATE ISSUED: 11/03/2014 OWNER'S PHONE: 4087995070 MILPITAS,CA 95035 PHONE NO:(650)520-9918 sr LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL F� COMMERCIAL INSTALL 32 FLUSH MOUNTED PV PANELS,8.32 KW License Class � Lie.# 61-D 7 32 Contractor U,. ate I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. hereby affirm under penalty of perjury one of the following two declarations: have and will maintain a certificate of consentto self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25500 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36223034.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION 1 certify that 1 have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM AST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the t All granting of this permit. Additionally,the applicant understands and will comply Is a Date: with all non-point source regulations per the Cupertino Municipal Code,Section 9.18, RE-ROOFS: Signature Date �1 i f All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,1 agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this � / Owner or authorized agent: -"'-'--Bate: r/ 3,,r y permit is issued. I certify that in the performance of the work for which this permit is issued,1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,1 CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,1 must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address 1 certify that I have read this application and state that the above information is correct.1 agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, ARCHITECT'S DECLARATION costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO FEE ESTIMATOR- BUILDING DIVISION ADDRESS: 11441 S STELLING RD DATE: 11/03/2014 REVIEWED BY: MELISSA APN: 362 23 034 BP#: b 'VALUATION: 1$25,500 ~PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: PERMIT TYPE: WORK INSTALL 32 FLUSH MOUNTED PV PANELS 8.32 kW SCOPE F] --L- , LJ _L_ NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . Thesefees are based on the preliminary information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resuhilion 11-053 EJf 7%1.'1.31 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 $236.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Feer Reg. Q OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 0 Work Without Permit? 0 Yes Q No $0.00 Advanced Planning Fee: $0.00 Select allon-Residential G Building or Structure Strong Motion Fee: 1BSEISMICR $3.32 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $2.001 1 SUBTOTALS: $5.32 $236.00 TOTAL FEE: 1 $241.32 Revised: 10/01/2014 ALTERNATIVE ENERGY PERMIT APPLICATION O\ 12 COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION o 10300 TORRE AVENUE•CUPERTINO CA 95014-3255 408 777-3228• FAX 77-3 it in cu ertino. \ _ ( ) AX(408)7 333• bud 4 a(� p orq a CUPi=R"I I NO \ PROJECT ADDRESS r 1 y y I S APN 9 '?'/c 7 - 3 OWNER NAME ^ PHONE STREET ADDRESS `I y l I 1 1^ � CITY, STATE �P^o 15-4, S J(y FAX cA CONTACT NAME l / T PHON mr� / E-MAIL �e d_1 4f? 5�'^^�ortc -0: e L.%b e-, V" �6 s T-2,9 11,7koagr-�� STREET ADDRESS �, CITY,STATE, ZIP FAX 47� ✓� �✓,� l`I�� ,�zs CA 1So3S 6S. )3S0 b33I ❑ OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAM�j LICENSE NUMBERS Z J32 LICENSE TYPE C y b BUS.LIC# Sun w rrR ICeYte�vabl�. COMPANY NAME E-MAIL-"""'" FAX STREET ADDRESS - � kS „('la^fi _ CITY,STATE,ZIP PHONE ARCHITECT/ENGINEERNAME •�K�' LICENSENUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESSCITY,STATE,ZIP PHONE USE OF P"/AFD Or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: E] Commercial URBAN INTERFACE AREA ❑ Yes O FLOOD ZONE ❑ Yes (� o I77 SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR,SOLAR PANELS: NUMBER OF PANELSIUNITS: 2— KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION DESCRIPTION CF WORK y / ) ,J r �+ / / .d�. If l✓ 1 i-y [ O J.1- )O I r�/" V s f#0-.r'1 2 (S RECEIVED BY:' t By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating�uild�onstruction. I authorize representatives of Cupertino to enter the abov�d�ified property for inspection purposes. Signature of Appl icant/Agent: Date: (I 3 ,y SUPPLEMENTAL INFORMATION REQUIRED ~oFP>c USE oizY; OVER-THE COUNTER � <,❑ EXPRESS U r STANDARD, U z a ❑, LARGE F' ❑ MAJOR PVApp_2011.doc revised 03/16/11 Mare efficient Shade management Easier 3 Secure Power Supply Broad temperature range Flexible communications A NEW GENERATION OF INNOVATION THE SUNNY BOY TL-US RESIDENTIAL SERIES HAS YET AGAIN REDEFINED THE CATEGORY- Transformerless design in all types of climates and for longer periods of Leading monitoring time than with most traditional string inverters. and control solutions The Sunny Boy 3000TL-US / 380OTL-US / 4000TL-US / 5000TL-US / 6000TL-US / Secure Power Supply The new TL-US residential line features more 7000TL-US / 770OTL-US are transformerless than high performance and a large graphic e inverters, which means owners and installers One of many unique features of the TL-US display. The monitoring and control options benefit from high efficiency and lower weight. residential series is its innovative Secure provide users with an outstanding degree of A wide input voltage range also means the Power Supply. With most grid-tied inverters, Flexibility. Multiple communication options - inverters will produce high amounts of power when the grid goes down, so does the solar- allow for a highly controllable inverter under a number of conditions. powered home. SMA's solution provides and one that can be monitored on Sunny daytime energy to a dedicated power outlet Portal from anywhere on the planet via an Additionally, transformerless inverters have during prolonged grid outages, providing Internet connection. Whether communicating < been shown to be among the safest string homeowners with access to power as long as through RS485, or SMA's new plug-and-play inverters on the market.An industry first, the TL- the sun shines. WebConnect, installers can find an optimal US series has been tested to UL 1741 and UL solution to their monitoring needs. 1699B and is in compliance with the arc fault Simple installation ti requirements of NEC 2011, Wide Power Class Range K As a transformerless inverter, the TL-US Increased energy production residential series is lighter in weight than Whether you're looking for a model to .J 4 its transformer-based counterparts, making maximize a 100 A service panel or trying OptiTracTm Global Peak, SMA's shade- it easier to lift and transport. A. new -,all to meet the needs of a larger residential PV tolerant MPP tracking algorithm, quickly mounting plate features anti-theft security and system, the Sunny Boy TL-US with Secure adjusts to changes in solar irradiation, which makes hanging the inverter quick and easy.A Power Supply has you covered. Its wide mitigates the effects of shade and results in simplified DC wiring concept allows the DC range of power classes—from 3 to 77 kW— z higher total power output.And,with two MPP disconnect to be used as a wire raceway, offers customers the right size for virtually any n- trackers, the TL-US series can ably handle saving labor and materials. residential application. The TL-US series is not - complex roofs with multiple orientations or only the smartest inverter on the planet,it's also s string lengths. The 380OTL-US and 770OTL-US models allow the most flexible. installers to maximize system size and energy An extended operating temperature range of production for customers with 100 A and 200 -40 OF to+140 OF ensures power is produced A service panels. Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC ------ -- ---- -----. Efficiency curve SUNNY BOY 5000TL-US-22 240Vac- ------------ Accessories 96 ._ r . •• Speedwire/Web<onnecf RSdBS interface 96' /• �.... .............. ................ interface DM-d85C&0510 t. - .............. .-... SWDM US 9d o i � u 92' °B- ----- _ - -- Fan kit for SB 3000/3800/ 90 1 - d000/5000TL-US22 w FANKIT02-10 88 J Bo Nry 175 VI °e - B.tV, 400 A -175 +ao 86 ► _.. Cta N� 480 A M. ..-. ..:. 0.0 0.2 0.4 0.6 0,8 1.0 • Standard feature O Optional feature Not available Output pourer/Rated power -------------------------------------- Data at nominal conditions Sunny Boy 5000TL-US Sunny Boy 6000TL-US Sunny Boy 7000TL-US Sunny Boy 770OTL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 5300 W 6300 W 7300 W 8000 W 600 V 600 V 600 V 600 V 175-480 V 210-480 V 245 -480 V 270-480 V 125-500 V 12.5-500 V 125-500 V 125 -500 V 125V/1,50V 125V/150V 125V/ 150V 12.5V/150V 30A/15A 30A/15A 30A/18A 30 A/18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208V/• 240 V/• 208 V/• 240 V/• 208 V/• 240 V/• 208 V/• 240 V/• 183 -229 V 211 -264 V 183-229 V 21 1 -264 V 183 -229 V 211 -264 V 183 -229 V 21 1 -264 V 60 Hz/59.3-60.5 Hz 60 Hz/59.3-60.5 Hz 60Hz/59.3 -60.5 Hz 60 Hz/59.3-60.5 Hz 22A 25A 29.2 A 32A I I 1 1 1/2 1/2 1 /2 1/2 <4% <4% <4% <4% 97.2% 97.6° 97.0% 97.4% 96.8% 96.8% 96.8% 97.3% 96.5% 97,0% 96.51 97.0% 96.5% 96.50a 96.5% 96.5% • • • • 1I 490/519/ 185 (19.3/20.5/7.3) 187/297/ 190 (7.4/ 11.7/7.51 617/597/266 (24.3/23.5/ 10.51 370/240/280 (14.6/9.4/ 11.0) 24<9 (53 tb)/3.5 kg (8 Ib) 27<g (60 lb)/3.5 kg (8 Ib) -40`C .+60 'C {-40 'F...+140'F) <29 dB(A) <29 dB(A) <29 dB(A) <29 dB(A) < I W < 1 W < i W < 1 W Trar9sfom wi miti Tronsfor-nerless Transformerless Tra.nsformerless Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R NEMA 3R 0/0 0/0 0/0 0/0 6/0/0 6/0/0 •/0/0 •/0/0 UL 1741,UL 1998,UL 16998,IEEE1547,FCC Part 15(Class A&B),CAN/CSA C22.2 107.11 SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US-22 SB 7700TL-US-22 7,77-7 SUNNY BOY 300OTL-US / 380OTL-US /4000TL-US 500OTL-U S /` 600OTL-U S / 700OTL-U S / 7700TL-U S "Juildin9 r ' (_� r i t`l l - ,- ._...�—'� �+'w�'�W't✓� LAY _^�s/'�'4' ,r"'-s�n,.Gs�r'.. r a THE W RL1'S ONLY SECURE POWER SUPPLY � Certified Innovative Powerful Flexible • UL 1741 and 1699B compliant •Secure Power Supply provides • 97.6%maximum efficiency •Two MPP trackers provide • Integrated AFCI meets the require- daytime power during grid outages Wide input voltage range numerous design options ments of NEC 2011 690.1 1 • Shade management with OpfiTrac Extended operafing Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 380OTL-US /400011-US / 5000TL-U S / 6000TL-U S / 7000TL-U S / 770OTL-U S Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/b000TL-US/70001-L-US/7700TL-US represents the next step in performance for UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTm Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power �POEtN rHf G9 Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative * * features make the Sunny Boy 1-L-US series the first choice among solar professionals. o 5- -A � Q4 O 9ti�/MPOR'tF' Technical data Sunny Boy 3000TL-US Sunny Boy 380OTL-US Sunny Boy 4000TL-US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC Input(DC) Max.usable DC power(@ cos W= 1) 3200 W 4200 W 4200 W Max.DC voltage 600 V 600 V 600 V Rated MPPT voltage-ange 175 -480 V 175-480 V 175-480 V MPPT operating voltage range 125 -500 V 125 -500 V 125-500 V Min.DC voltage/start voltage 125 V/ 150 V 125 V/ 150 V 125 V/ 150 V Max.operating input current/per MPP tracker 18A/15A 24A/15A 24A/ 15A Number of MPP trackers/strings per MPP[rocker 2/2 Output(AC) AC nominal power 3000 W 3330 W 3840 W 4000 W Max.AC apparent power 3000 VA 3330 VA 3840 VA 4000 VA Nominal AC voltage/adjustable 208 V/• 240 V/• 208 V/• 240 V/• 208 V/• 240V/• AC voltage range 183-229 V 211 -264 V 183 -229 V 211 -264 V 183 -229 V 211 -264 V AC grid frequency,range 60 Hz/59-3-60.5 Hz 60 Hz/59.3-60.5 Hz 60 Hz/59.3 -60.5 Hz Max.output current 15 A 16 A 20A Power factor(cosy) 1 1 I Output phases/line connections` � �, 1 /2 1/2 1/2 Harmonics <4% <4% <4% Efficiency Max.efficiency 97.2% 97.6% 97.2% 97.5% 97.2% 97.5% CEC efficiency 96.5% 96.5% 96.5% 97.0% 96.5% 97.0% Protection devices DC disconnection device • DC reverse-polarity protection I loop • Ground fault monitoring/Grid monitoring , 0/0 AC short circuit protection • All-pole sensitive residual current monitoring unit R P v �; • Arc fault circuit interrupter(AFCI)compliant to UL 16998 Protection class/overvohage category e �,; '',�j; `;2s .s��`�°°�;, 4'a° I/IV General data Dimensions(W/H/D)in mm(in) 490/519/ 185 (19.3/20.5/7.3) DC Disconnect dimensions(W/H/D)in mm(in) 187/297/ 190 (7.4/ 11.7/7.5) Packing dimensions(W/H/D)in mm(in) 617/597/266 (24.3/23.5/10.5) DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280 (14.6/9.4/11.0) Weight/DC Disconnect weight 24 kg (53 Ib)/3.5 kg (8 ib) Pocking weight/DC Disconnect packing,veight 27 kg (60 Ib)/3.5 kg (8 Ib) Operating temperature range -40 `C...+60°C (-40'F_+140°F) Noise emission(typical, 5 25 dB(A) <25 dB(A) <25 dB(A) Internal consumption at night < 1 W < 1 W <1 W Topology Tronsformedess Tronsformerless Transformerless Cooling Convection Convection Convection Electronics proter_tior.rating NEMA 3R NEMA 3R NEMA 3R Features Secure Power Supply • • • Display:graphic • • Interfaces:RS485/Speedwire/Webconnect 0/0 ",'0 0/0 Warranty: 10/ 15/20 years 6/0/0 0/0/0 0/0/0 Certificates and permits(more available on request) UL 1741,UL 1998,UL 1699B,IEEE 1547,FCC Part 15(Class A&B),CAN/CSA C22.2 107 1-1 NOTE:US inverters ship with gray lids Type designation SB 3000TL-US-22 SB 380OTL-US-22 SB 4000TL-US-22 Solar Pass Through Boxes C R O US E-H IND S COMMERCIAL PRODUCTS Applications: Certifications and Compliances: Cooper Crouse-Hinds Solar Pass Through Boxes(sometimes NEMA 4X referred to as"transition boxes")are used in residential applications to provide a low profile,cost effective way to group input Materials and Finishes: wires/circuits from several arrays and/or solar panels and transition from solar(PV)cable to regular building wire. The Pass Through Box • Hat compression molded fiberglass reinforced thermoset polyester was designed for PV applications where over current protection is not necessary due to the low power rating of the PV string. Non-Conductive,impact resistant,UV resistant,flame retardant • Poured Polyurethane seamless gasket provides water-tight,dust- Features: tight environmental seal • Rated 60OVDC continuous duty • Stainless steel used on all external hardware • Constructed in accordance with UL 1741 standards providing spacious wiring room for quick easy wire termination • Factory installed multi-hole solar cord grip provides dependable secure wire termination to enclosure and saves field installation- eliminating the need for enclosure drilling-saving time&labor 0 • Fiberglass enclosures with captive stainless steel screws and CAuTION formed-in-place polyurethane seamless gasket provided as l standard _ a • Available in N3R sheet steel enclosures-consult factory • Light weight design offers easy mounting capabilities.Optional mounting feet are available for increased customer flexibility � 0 A CAUTION x Solar Pass Through Box Ordering Information Cat.q Description CPBF03 3 Circuit Pass Through Box CPBF04 4 Circuit Pass Through Box cva+++r�'• For additional configurations,please consult factory disc- be required tO de-CrIe'gize the ~ tJF'IER ,,.jPMenj before rrNO ts��ldr �g o epar"en* NOV 0, X014 LIANi;& Reviewea By ._ . 284 www.crouse-hinds.com US:1-866-764-5454 CAN:1-800-265-0502 Copyright' 2012 Cooper Crouse-Hinds WOO&Crouse-Hinds . . . .a . , , . . • \ .. . . ID $ � ® f $ : NJ w . � : k C: 2 : / } m : {� � :3 CD ® M 2 e y $ \ / / _ rD - - o ` 03 n Ln \ $ % s \ _ \ aj m / . � /! : • � / 2 , � it P • Y�hAhd�} y .', f f � y F�� . �a z,�saY a tr �.r.MR�Y�a�-0Su�"e•.f1+T A'tM. F Y 'r xi�,S:iF`1 tf ti iv i y + • y, o � • t �Yb ■ ■ OU [ Unirac Code-Compliant Installation Manual So1arNlount 10 year limited Product Warranty, 5 year limited Finish Warranty Univac,Inc.,warrants to the original purchaser specified by AAMA 609&610-02—"Cleaning If within the specified Warranty periods the ("Purchaser")of product(s)that it manufactures and Maintenance for Architecturally Finished Product shall be reasonably proven to be ("Product")at the original installation site that Aluminum"(www.aamanetorg)are not Followed defective,then Unirac shall repair or replace the the Product shall be free from defects in material by Purchaser.This Warranty does not cover defective Product,or any part thereof,in Unirac's and workmanship for a period often(10)years, damage to the Product that occurs during its sole discretion.Such repair or replacement shall except for the anodized Finish,which finish shipment,storage,or installation. completely satisfy and discharge all of Unirac's shall be free from visible peeling,or cracking or liability with respect to this limited Warranty. This Warranty shall be VOID if installation of the chalking under normal atmospheric conditions Product is not performed In accordance with Under no circumstances shall Unirac be liable for a period of Five(5)years,from the earlier Unirac's written installation instructions,or if the for special,indirect or consequential damages of 1)the date the installation of the Product is Product has been modified,repaired,or reworked arising out of or related to use by Purchaser of completed,or 2)30 days after the purchase of the Product. in a manner not previously authorized by Univac the Product by the original Purchaser("Finish IN WRITING,or if the Product is installed in Manufacturers of related items,such as PV Warranty"). an environment for which it was not designed. modules and flashings,may provide written The Finish Warranty does not apply to any foreign Unirac shall not be liable for consequential, warranties of their own.Unirac's limited Warranty residue deposited on the Finish.All installations contingent or incidental damages arising out of covers only its Product,and not any related items. in corrosive atmospheric conditions are excluded. the use of the Product by Purchaser under any The Finish Warranty is VOID if the practices circumstances. U N I RAC 1411 Broadway Boulevard NE �� Albuquerque NM 87102-1545 USA SolarMount Unirac Code-Compliant Installation Manual OPO U N I RAC [3.4] Installing SolarMount with grounding clips and lugs Clips and tugs are sold separately. UGC-1 To 'f mounting �T� clamps I I ( Module T-bolt Nib q a.4Figure 26.Slide UGC-1 grounding IUGC-1 aclip into top mounting slot ofrail. �i v Torque modules in place on top of Conforms to -- - clip.Nibs will penetrate rail anod- ut_sw,dard 467 iaation and create grounding path through rail(see Fig.3,reverse side). SolarMountO rail(any type) Figure 27. Insert a bolt in the W E E B Lug aluminum rail or through the clearance hole in the stainless steel flat washer.Place the stainless steel flat washer on the bolt,oriented so the dimples will contact the aluminum rail.Place the lug portion I � on the bolt and stainless steel flat 11 washer.Install stainless steel flat �� washer,lock washer and nut. NEEBLug Tighten the nut until the dimples are completely embedded into the rail �r- and lug.The embedded dimples make Stainless Steel Flat a gas-tight mechanical connection — Washer(WEEB) and ensure good electrical connection between the aluminum rail and the lug through the WEEB. - ``> y—' ounjO rail j (any type) Figure 28.UGC-1 layout for even Figure 29.Single wire grounding and odd number of modules in row. with spliced rails. "X"denotes places to install UGC-1. KEY �! PV module , Solornnouni rail(ary ype) Rad splice X Grounding lug Even Number of Modules in row — copper wire I Odd Number of Modules in row Single grounding wire for entire array �xr 25 SoLARMouNT Technical Datasheets ] 1 R A C SolarMount Beams Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight(per linear ft) plf 0.811 1.271 Total Cross Sectional Area int 0.676 1.059 Section Modulus(X-Axis) in 0.353 0.898 Section Modulus(Y-Axis) in' 0.113 0.221 Moment of inertia(X-Axis) in' 0.4664 1.450 Moment of Inertia(Y-Axis) in 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 SLOT FOR T-BOLT OR 1.728 SLOT FOR T-BOLT OR 1�" HIX HEAD SCREW 1/a"HEX HEAD SCREW 2X SLOT FOR SLOT FOR BOTTOM CLIP 2.500 BOTTOM CLIP 4T 3.000 1.316 SLOT FOR 0 "HEX BOLT SLOT FOR 1.185 Lr— Us" HEX BOLT j .387 .750 1.207-� Y 1.875 �{ i ►X X SolarMount Beam SolarMount H.D Beam Dimensions specified in inches unless noted a UNIRAC 'r.,.. SolarMount Beam Connection Hardware SolarMount L-Foot ?art No, 310065, 310066, 310067, 310068 • L-Foot material: One of the following extruded aluminum alloys:6005- T5, 6105-T5, 6061-T6 -�'�� Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear or Dark Anodized ~ L-Foot weight: varies based on height:—0.215 lbs (98g) i Allowable and design loads are valid when components are Bea assembled with SolarMount series beams according to authorized Bolt UNIRAC documents L-Foot For the beam to L-Foot connection: •Assemble with one ASTM F593 W-16 hex head screw and one errated l ASTM F594'/e'serrated flange nut Flange Nu • Use anti-seize and tighten to 30 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test Y results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only; be —�X sure to check load limits for standoff,lag screw,or other attachment method 3.01 Applied Load Average Safety Design Resistance 3X SLaT FOR Direction Ultimate Allowable Load Factor, Load Factor, HARDWARE lbs(N) Ibs(N) FS lbs(N) 0 2.01 _ i Sliding,Z± 1766(7856) 755(3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859(8269) 707(3144) 2.63 1069(4755) 0.575 Dimensions specified in inches unless noted I Compression, Y- 3258(14492) 1325(5893) 1 2.461 2004(8913) 1 0.615 Traverse,X± 486(2162) 213 (949) 1 2.28 323(1436) 0.664 TechnicalSOLARMouNT Datasheets s: UNIRACH SolarMount Technical Datasheet Pub 100602-1 td V1.0 June 2010 SolarMount Module Connection Hardware.................................................................. 1 BottomUp Module Clip.................................................................................................1 MidClamp ....................................................................................................................2 EndClamp....................................................................................................................2 SolarMount Beam Connection Hardware......................................................................3 L-Foot...........................................................................................................................3 SolarMountBeams..........................................................................................................4 uPERTINO Building Department NOV 0 3 2014 SolarMount Module Connection Hardware kEV!(=it1rEC1 r(;Ur2 CODE'COMPLIANCE SolarMount Bottom Up Module flip rteviewec 13y � -• ,�7�Twi Part No. 321001, 321002 Washer Bottom Up Clip material: One of the following extruded aluminum Bottom Nut (hidden..se alloys: 6005-T5, 6105-T5, 6061-T6 y Up Clip no Ultimate tensile: 38ksi,Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: -0.031 lbs(14g) Bolt Allowable and design loads are valid when components are Beam assembled with SolarMount series beams according to authorized UNIRAC documents Assemble with one '/4'-20 ASTM F593 bolt, one '/4"-20 ASTM F594 serrated flange nut, and one 114"flat washer Use anti-seize and tighten to 10 ft-lbs of torque �\ Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Average Allowable Safety Design Resistance Direction Ultimate Load Factor, Load Factor, -- lbs(N) lbs(N) FS lbs(N) m r N 1.24 Tension,Y+ 1566(6967) 686 (3052) 2.28 1038(4615) 0.662 Y Transverse,X± 1128(5019) 329(1463) 3.43 497(2213) 0.441 1 ►X ^� l.aa Sliding, Z± 66(292) 27 (119) 2.44 1 41 (181) 0.619 Dimensions specified in inches unless noted a 'e SOIARMOUm Technical_. . . . - - UN1RAC A�IL1-i SRQI�P[�Iy�paNV SolarMount Mid Clamp Part No.320008,320009,320019,320020,320021, 310084,321)085,320086,320087,320120,320122 Mid clamp material: One of the following extruded aluminum Mid rra Bolt alloys: 6005-T5, 6105-T5, 6061-T6 Fla e N • Ultimate tensile: 38ksi, Yield: 35 ksi Clamp • Finish: Clear or Dark Anodized Mid clamp weight: 0.050 lbs (23g) 1 \ Allowable and design !oads are valid when components are assembled according to authorized UNIRAC documents Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated Assemble mid clamp with one Unirac'/4"-20 T-bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti-seize and tighten to 10 ft-lbs of torque Beam Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Average Allowable Safety Design Resistance LOO DISTAN4T - Direction Ultimate Load Factor, Load Factor, 8E.':VEEN MOOUi;.s lbs(N) lbs(N) FS lbs (N) m Tension,Y+ 2020(8987) 891 (3963) 227 1348 (5994) 0.667 --- Transverse,Z± 520(2313) 229(1017) 2.27 346(1539) 0.665 Y � --- ______ Sliding,X± 1194(5312) 1 490(2179) 1 2.44 1 741 (3295) 1 0.620 --►X Dimensions specified in inches unless noted SolarMount End Clamp Part No.320002,320003,320004,320005,320006, 320012,320013,320014,320015,320018,320017, 320079,320080,320081,320082,320083,320117, 320118,320123,320124,320173,320185,320220, End clamp material: One of the following extruded aluminum 320233,320234,320331 alloys: 6005-T5, 6105-T5, 6061-T6 Ott Ultimate tensile: 38ksi,Yield: 35 ksi Finish: Clear or Dark Anodized -- ' End clamp weight:varies based on height: -0.058 lbs(26g) 1 d Clamp Allowable and design loads are valid when components are Serrated assembled according to authorized UNIRAC documents Flange Nut Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'W-20 T-bolt and one '/4'-20 ASTM F594 serrated flange nut / Bea \ Use anti-seize and tighten to i 0 ft-lbs of torque Resistance factors and safety fai torn are determined according to Y part 1 section 9 of the 2005 Aluminum Design Manual and third- ` party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam �X -s Applied Load Average Allowable , Safety Design Resistance MwIMu_,' Direction Ultimate Load Factor, Loads Factor, ' HEIGHTlbs(N) lbs(N) FS lbs(N) 4 =J VARIES WITH Tension,Y+ 1321 (5876) 529(2352) 2.50 800(3557) 0.605 MODULE '.. THIIXNE55 r Transverse,Z± 63(279) 14(61) 1 4.58 21 (92) 0.330 - Sliding,X± 142(630) 52(231) 1 2.72 79(349) 0.555 Dimensions speci d HIGH PERFORMANCE SOLAR PANELS REE PEAK ENERGY BLK REC Peak Energy BLK Series panels are the perfect choice for building solar systems that combine long lasting procuct quality with re!iadle power output. REC corn vines high quality design and ndards to produce high- manufacturing sia performance solar panels with uncom. romising quality. 1 �w 1 MOREPOWER ROBUSTAND PER FT' DURABLE DESIGN A LEADING EMPLOYER IN EASY TO THE US SOLAR INDUSTRY INSTALL _ ° "EEK ENERGYBLK 'S 6555±0.I 35.43 15,06 _-_.- EFFICIENCY y YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY i _ I �o DUTY* US IMPORT DUTY FFEE 0 0 AFF H{{ 0.43 n ±0.08 7 o Mauntindhalas 41 1TEMPERATURE ;� � �' �• Nominal Operating Cell Temperature(NOCT) 457C(+-2'C) vP Temperature Coefficient of P,,,,,P -0.40%/°C », Temperature Coefficient of VeC -0.27%/'C - � Temperatui e Coefficient of 1, 0.024%/`C All measurements in inches -` ELECTRICAL DATA @ STC REC23SPE REC240PE REC24SPE REC25OPE1 Nominal Power P, (W Z35 Z40 245 Z50 255 Z60 Cell Type: 60RECPEmulti-crystalline p) 3 strings of 20 cells with bypass diodes Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 Glass: 1/8"mm solar glass with anti-re Flection Nominal Power Voltage-V,,,,(V) 29.5 29.7 30.1 30,2 30.5 30.7 surface treatment Nominal Power Current-1„z(A) 8.06 8.17 8.23 8.30 8.42 8.50 Back Sheet: Double layer highly resistant polyester Open Circuit Voltage-V,,(V) 36.6 36.8 37.1 37.4 37.6 37.8 Frame: Anodized aluminium(silver) ShortCircuitCurrent-l- (A) 8.66 8.75 8.80 8.86 8.95 9.01 Junction Box: IP67rated 4 mm2 solar cable.35"+47" Panel Efficiency(1/6) 14.2 14.5 14.8 15.1 15.5 15.8 Connectors: MC4(4mm') Analysed data demonstrates that 99.7%of panels produced have current and voltage tolerance of t3%from nominal values. MC4 connectable(4 MM2) Values at standard test condi tions',It-(airm ass AM Lt),irradiance I iIW/m',cell temperature 25%j. At low irradiance of 200 W/m�(AM 1.5 and cell temperature 25"C)at least 97%of the STC panel efficiencctwill be achleved. Radox twistlock connectors(4 MM2) li SILK ILK BILK BLIK BLK • Operational Temperature: -40...+80"C Nominal Power-P„Pp(Wp) 179 183 187 189 193 197 Maximum5ystem Voltage: 600V Nominal PowerVoltage-V,,,p<,(V) 27.5 27.7 28.1 28.3 28.5 29.0 Design Load: 75.21bs/ft2(3600 Pa)* Nominal Power Current-I.,(A) 6.51 6.58 6.54 6.68 6.77 6.81 33.41bs/ft2(1600Pa) Open Circuit Voltage-VocIV) 34.2 34.4 34.7 35.0 35.3 35.7 "Refertoinstallation manual Short Circuit Current-Isc(A) 6.96 7.03 7.08 712 721 7.24 Max Series Fuse Rating: ISA Nominal operating cell temperature NOCT(800 lml,AM 1.5,windspeed 1 m/s,ambient temperature 20'C). Max Reverse Current- ISA CERTIFICATION MECHANICALDATA 10 year product warranty. Dimensions. 65 l/2 x 39 x l I/2 in C @usCE Fol 25 year linear power output warranty Area: 1776ft2 USTED (max.degression in performanceof 6.7%p.a.). UL 1703,IEC 62716(ammonia resistance)&IEC 61701 Weight: 39.6 lbs (saItmistcorrosion-severitylevel6). Note!All given specifications are provisional data only and subject to change without notice at any time. REC is a leading global provider of solar electricity solutions.With nearly two decades of expertise,we offer sustainable,high-performing ��� products,services and investment opportunities for the solar and electronics industries.Together with our partners,we create value by provid(ngsolutions that better meet the world's growing electricity needs.Our 2,300 employees worldwide generated revenues of more than NOK 7 billion in 2012,approximately USD 1.3 billion. www.recgroup.corn 835 Aerovista Place,Ste 230 San Luis Obispo,CA 93401 Dir 805 704 3226 ^E C Fax 805 457 6104 �`! I r�carouo.com SunWork Renewable Energy Projects PO Box 60250 Palo Alto, CA 94306 ATTN: Reuben Veek RE: Unirac UGC-1 Clip Grounding Authorization San Luis Obispo, May 18, 2012 To Whom It May Concern: REC Solar approves the the Unirac UGC-1 product to electrically bond and ground the REC Peak Energy series module frame. Using this system meets the manufacturer requirements for bonding and grounding and will not void the warranty for installations performed in accordance with the manufacturer's guidelines. Best regards, George McClellan REC Solar US LLC Technical Sales Manager 1 ! PROJECT DETAILS: PROPERTY LINES: PERMITTING AUTHORITY NOTES: ARRAY PITCH: 9.50/9.50 (2:12 /2:12) __——_,_—___y 1 , e ARRAY FACING: 1780/268° (S/W) GOMMUNfTY DE`" — -T nA-RTMEILT BUILDING u! ,=RTINO SITE LATITUDE: 37.000 (3710'N) ' This set of plans and s,- :. -'-ST be kept at the job site during constru_. I-wful to make any TYPE OF STRUCTURE: residence changes or altera'L .. or to deviate therefrom, without app, i;. wilding Official. ROOF CONSTRUCTION: 2:12 post and beam, �, ; The Stamping of this pic:'. ; = .`: bid"s SHALL NOT 1 1/2 tongue and groove over 4x8 beams, , spaced 72" on center, 12' 6" maximum span to held to permit or to c the violation Gi r State Law. AGE OF STRUCTURE: 60 years ❑ ss oad oo, 3 ly ROOFING TYPE: dimensional composition shingle over sheathed foam board ";;SIT 6 AGE OF ROOFING: 3 years NUMBER OF STORIES: 1 EXPOSURE CATEGORY: B 40IFFILrJPy i HOUSE ACCESS REQUIRED: no PILA17,15 CONTACT NAME: Sunil Ramesh ___________________________________________________ -__ HECKED BY ,1 N DATE C TACT PHONE NUMBER: (408) 799-5070 cell CUPERTINO?45 01DECEIVED s 801ding Department SPTGir, .�., -- �9��j N OV 0 3 2014 Y ,. iti 1x11 -.- _ NOV 0 3 2014 ; ' DAT.r 'Y: n REVIEWED FOR CODE COMPLIANCE X33/. Reviewed By. BLDG. nFa� 1 1/ o , Project DrawingEIv 14 CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc_stc SYSTEM RATING: X.XXX 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 Sunftrk Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (32) AUTHORITY Renewable Enemy_ tts (650) 520-9918 T _ O HAVING JURISDICTION. City of Cupertino INVERTER TYPE AND NUMBER. SMA Sunny Boy 7000 L US (1),., CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.PD.A.01 SCALE: 1:240 (1 inch = 20 feet) ------------ - ---=-'-' -==•--- Existing Main Service Switch ' STRUCTURAL LOAD CALCULATIONS: 3/a" EMT conduit carrying 4, - - -- ---, - 3/a' RMC conduit carrying 3, #6 AWG THWN-2 conductors(2 [As per ASCE 7-10,see Unirac design load #8 AWG THWN-2 ungrounded ac lines and ac neutral)and 1,#8 AWG THWH-2 worksheet for additional detail] conductors(2 do positives \ conductor(equipment ground) and 2 do negatives)and 1, #10 AWG THWH-2 t conductor(equipment 60-amp NEMA 3R fusible AC Disconnect, mounted on Building height= 10 ft ground),with penetration exterior wall Building least horizontal dimension=32 ft through the eave ' Risk category=II waterproofed using an Exposure category=B ' 3/4" EMT conduit 2,#8 AWG THWN-2 conductors(2 EPDM-collared galvanized ungrounded ac lines)and 2,#10 AWG THWN-2 conductors Roof pitch=9.5 degrees roof flashing (ac neutral and equipment ground) Roof zone location=3-corner zones Effective wind area= 16.4 sf 3.0-kilowatt NEMA 3R grid-tie Solar Inverter with NEC Basic wind speed= 110 mph compliant integrated DC Disconnect, mounted on exterior wall Net design wind pressure= 12.5 psf, -51.3 psf Adjustment factor for height and exposure= 1 Topographic factor= 1 Design wind load=(12.5 psf, -51.3 psf, x 1 x 1 FRONT OF HOUSE _<12.5 psf, 51.3 psf, F-1Dead load=2.5 psf Snow load=0 psf Sub-array of 16,260-watt - NEMA 4 Solar Pass-Through Total design load, downforce case 1 Photovoltaic Modules, Box, mounted to array rail =2.5 psf+0 psf=2.5 psf mounted using Unirac ----------------------- beneath array Total design load, downforce case 2 SolarMount standard rail �' =2.5 psf+ .6 x 12.5 psf= 10.0 psf Total design load, downforce case 3 attached to beams every 72 2.5 psf+ .45 x 12.5 psf+ .75 x 0 psf=8.1 psf using lag screws, with - Sub-array of 16,260-watt Total design load, uplift penetrations through the ;` Photovoltaic Modules, composition shingle flashed mounted using Unirac = .6 x 2.5 psf+ .6 x-51.3 psf=-29.3 psf using Eco Fasten Solar :@ • SolarMount standard rail aPer penetration area= 16.4 sf GreenFasten EPDM-bushed attached to beams every 72" Point load, dead=2.5 psf x 16.4 sf=41 lbs aluminum roof flashings and using lag screws,with sealed using a high o penetrations through the Point load, downforce= 10.0 psf x 16.4 sf= 164 lbs performance scypolymer ...-...--.....-.... compo i , flashed UPERT&ad, uplift=-29.3 psf x 16.4 sf=-481 lbs N bonding sealant using E olar Building Department Green ' en -bushed alumin ings and Lag screw type=5/16"x 8"SS sealed " 2014 Embedded thread depth=8"-5/ar- 23/4" igh- ��@� performance scypolymer Beam wood type=Douglas Fir-Larch bondin 5/16"lag screw withdrawal cap.=266 lbs/in �fPtNEG FGR CODE COMPO iNGEhdrawal cap.=23/4"x 266 lbs/in=731 lbs -------------- - Reviewed By ✓ /�m details=4x8 , 72 on center, 12'6"span Site Drawing CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc-stc SYSTEM RATING: x.xxx kWac-field 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 SI,InWOdC Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (32) AUTHORITY HAVING JURISDICTION: City of Cupertino Renewable Energy Projects (650) 520-9918 INVERTER TYPE AND NUMBER: SMA Sunny Boy 7000TL-US (1) CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.SD.A.01 SCALE: 1:120 (1 inch = 10 feet) - - 2x12"ridge beam 2x12" ridge beam - - - " II �� II II 4x4"posts i; IVi " I II II II II II 4x8"beams spaced - --,Y---- , IL —JL---------L---------JL---------JJ-----f-- 72"oncenter with4` 1r — 1T---------n----------Ir---------n--------- 11'6"maximum span ___=r II II II II II �� II II II II II II ;; II II II II II II 2x4"exterior walls with 4x8"beams spaced double top plates and r 11 I I I I I I I I 72"on center with studs 16"on center 11 12'6"maximum span II �� II 11 11 II 4x4"posts 2x4"exterior walls with double top plates ® ® ® / ® and studs 16"on I I 11 GUPERTINO Building NOY 0 3 7014 REVIEWED FOR CODE COMPLIANCE Reviewed By '64v f Framing Drawing CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc-,t, SYSTEM RATING: x.x(x kWac-field 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 Sunftrk ) Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (32) Renewable Energy.Pr-0jects (650) 520-9918 AUTHORITY HAVING JURISDICTION: City of Cupertino INVERTER TYPE AND NUMBER: SMA Sunny Boy 7000TL-US (1) CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.FD.A.01 SCALE: 1:60 (1 inch = 5 feet) � NICAL • TA pop REC Solar REC-260-PE BLK Photovoltaic Module MG!Greer)a, Unirac top-mounting clamp4 0 --r r • t � t 925BONDING SEALANT Adheres T«Asphalt ahNimsteel. 1/4" SS bolt and locking flange nut corx;rete,EPDM,primed TPO,paned 1.PRODUCT NAME PVC,I f palon(black onlrA.metal,wood. GeoGreen 45009 Roof Bonding Sealant and other common building substrates Univac SolarMount standard rail 2.MANUFACTURER: Cornposiumand Mate+bels GEOCEL LLC Proprietary.non-sohem technology P.O.Box 396 Gra &—.IN 46515 USA. de:Gln grade consistency Phone:(6001 3413-7615 Primer.Na required on most surfaces. 3/8" SS bolt and locking flange nut �. UA_„ „ ' °ap lipnmer requited & Geotel recommends using 45PT"low a PRODUCT DESCRIPTION: VOC,TPO s PVC Primer. GwGreen 45009 Roof Bonding Sealant Patina ' 10 R oz cwbdW EcoFasten Solar compression L-foot s`� .sa tp,opn,n« aolvem . Colors bonding sealant specificaly designed :Blas and white t + for rooGg applications and systema The U„itagp,az + advanced of 4500 Roof t , tecMobgy •Do not use on urlprimed TPO or PJC Seal uct anes EcoFasten Solar GreenFasten flashing immediately naprodpondin Do mernbinmedietey witheards ponding water .pro cwt see lack 4500 Roof Sealant while bondng to many rnmmcn roofing on while EPDM etbetratea. .Do not use white 45M Rod Sealant on black EPDNI Product Berwfft 0 Wes,adheres,and ct-res Existing composition shingle over sheathed foam board,with underwAer single-point penetration sealed using a high-performance - 2products n1-lap alwive8 scrim edge 50alam scypolymer bonding sealant(Geotel 4500, see Data Sheet) - No additional adhesives or sealants needed ■ Remains flexible ■ works with EPDM membranes.tape& and patches 5/16" SS lag screw and bonded sealing washer - Meets=&NMBguidelines - we,non-flartmeble,non-solvent formulation Ba6o Used For and rCveo/ S around through-roof poecoortss. ' "� .. .•O Existing 1 1/2"tongue and groove decking termination points,and flashings.Also,as ao.eo<aee an EPDM ase lap cement adlesive or scrum ` '€�,°_ 'F,�',Ms O edge sealant. t �rGF.�i� 11 Existing 4x8"beam 80ding Department NOV 0 3 2014 REVIEWED rOR GOOE COMPLIANCE reviewed Bir Attachment Detail CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc-stc SYSTEM RATING: X.xxx kWac-field -� -�- 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 SUnwO�C Milpitas, CA 95035 MODULETYPE AND NUMBER: REC Solar REC-260-PE BLK (32) Renewable Energy ccs (650) 520-9918 AUTHORITY HAVING JURISDICTION: City of Cupertino INVERTER TYPE AND NUMBER: SMA Sunny Boy 7000TL-US (1) CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.AD.A.01 SCALE: 1:2 (1 inch = 2 inches) ............................................................................................................................................................................................................................................................................................... : = + ELECTRICAL CALCULATIONS: REC Solar REC-260-PE BLK Photovoltaic Modules `�' `�' `�' `�' `�' `�' `�' `�' Q Q Q Q Q Q Q Q [As per the 2013 revision of the California Electrical Code,pertinent articles cited below] (2 separate pairs of2parallel ------------------------------------ PV Array Electrical source circuits of 8 in series) ................................................................................................................................... ... . . ......................................................................................................................................... Specifications: PmP= 8320 W Maximum System Voltage [690.71 + – + VmP= 246V Imp 17.0 A Array nominal open circuit voltage=302 V V(= 302 V Lowest temperature on record=-7�C o Open circuit voltage temperature coeff._-.27/o/�C ` --- ---- --- -- - - is, 18.0 A Low temperature voltage correction coeff. = 1.09 Limit open circuit voltage=302 V x 1.09=329 V #10 AWG PV-wire/RHW-2 positive 1 #10 AWG PV-wire/RHW-2 positive 2 #10 AWG PV-wire/RHW-2 negative 1 #10 AWG PV-wire/RHW-2 negative 2 Maximum Circuit Current [690.81 #10 AWG solid bare eq. ground bonded to mounting rails and module frames (1A) :............................................................................_............................_.._............................................._......................................................: Array nominal short circuit current= 18.0 A Square D D222NRB Possible sustained irradiance coeff. = 1.25 Existing General Switch 60 A AC Disconnect Limit short circuit current= 18.0 A x 1.25=22.5 A 9 SMA Sunny Boy 7000TL-US 100 A Single-Phase 240 V Grid-Tie Solar Inverter Main Service Switch Circuit 1 Allowable Continuous Current 240 Vac Class R L1 L2 N G DC1+ DC1- DC2+DC2- Crouse-Hinds 26 Cartridge 2A AWG t CPBF03 Solar Conductor size=#Conductor temperature attire titin 90� ( ) Fuses (2A) Pass-Through Box P 9= ( Base conductor ampacity[310.15]=55 A 16) i Highest ambient temperature=67�C ....: ................................................................... .......... ..................................... ....... ...................................... ................._................: ......................... ........�......: Ambient temperature derating coeff. [310.15]_.58 t7 - ----------------- --- - I 40A t-- ----------- ------------- +..................... ......................... Inverter Electrical Grouped current-carrying conductor count=4 100 A I Insulation- ------------- -- aecifications: Multiple conductor derating coeff. [310.15]_.80 S ° Piercing -------- _ - P – 7000 W Corrected am acity=55 A x.58 x.80=25.5 A _ P Connector — Vmax-dc= 600 V Allowable continuous current=25.5 A x.8=20.4 A Blocks i L-------J Imax-dc= 30.0 A Integrated 600 Vdc 36 A Vnom-ac– 240 V Circuit 2 Allowable Continuous Current 4-pole DC Disconnect Imax-ac= 29.2 A O _ _ Conductor size=# 8 AWG _ Conductor temperature rating=90C Base conductor ampacity[310.15]=55 A .........__ __...................................................__........_, Highe' em erature ................................... ..............._...._................................, _................. ......................................................_.............. _ s 3/d' EMT conduit: Ambi ure deratin 3/a" RMC conduit: I 3/a" EMT conduit: € # 8 AWG THWN-2 positive 1 Grou d, .=carrying co ,� � t UTILITY GRID Multi or derating coeff. 310.15 = 1 # 6 AWG THWN-2 line 1 # 8 AWG THWN-2 line 1 # 8 AWG THWN-2 negative 1 P t 9 [ 1 # 6 AWG THWN-2 line 2 # 8 AWG THWN-2 line 2 # 8 AWG THWN-2 positive 2 Corre ity �y+>D.t 47.9 A # 6 AWG THWN 2 neutral #10 AWG THWN 2 neutral # 8 AWG THWN-2 negative 2 Allowable continuous current=47. x.8=38.3 A # 8 AWG'THWN-2 eq. ground #10 AWG THWN-2 eq. ground #10 AWG.THW.N-2 eq.ground REVIEWED -OR LODE Ci)MPL.lAtVCat ..............._..... Reviewed By Electrical Drawing CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc_stc SYSTEM RATING: X.XXX kWac-field -- 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 SunWorkRenewable Energy Pro'�cts (650) 520-9918 Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (32) AUTHORITY HAVING JURISDICTION. City of Cupertino INVERTER TYPE AND NUMBER: SMA Sunny Boy 7000TL-US (1) CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.ED.A.01 SCALE: N/A PHOTOVOLTAIC PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT -WARNING- � � � � I II PHOTOVOITAKSYSTIA w Y REMAIN ENERGIZED SOURCE CIRCUIT WIRING MAY REMAIN ENERGIZED AFTER SYSTEM DISCONNECTION .SOURCE CIRCUIT WIRING MAY REMAIN ENERGIZED DISIT CONNECTION. DURING DAYLIGHT AFTER SYSTEM DISCONNECTION DURING NOMINAL OPERATING DC VOLTAGE 246 V NOMINAL OPERATING AC VOLTAGE 240 V NOMINAL OPERATING AC VOLTAGE 240 NOMINAL OPERATING DC CURRENT 17.0 A MAX OPERATING AC CURRENT 29.2 MAX OPERATING AC CURRENT 29.2 A MAX OPEN CIRCUIT DC VOLTAGE SHORTMAX Labeling for DC Disconnect, engraved sun resistant placard Labeling for AC Disconnect, engraved sun resistant placard Labeling for Main Service Panel, engraved sun resistant placard mechanically attached to the front surface of the enclosure of mechanically attached to the front surface of the enclosure of mechanically attached to the front surface of the enclosure of the existing the inverter-integrated do disconnect with aluminum rivets the ac disconnect with aluminum rivets main service panel with aluminum rivets I I I SON1 ,UPERTINO WIRING MAY REMAIN ENERGIZED A k suildin SYSTEM DiSCONNECTION DURING DAYLIGHT g Dwartment <..,, "=�? ^ '➢ ;`' 2014 Labeling for System Conduit, reflective outdoor sticker affixed at regular intervals to all do conduit runs '1=VIEvvE I_: rUk DUDE COMP, IANC �evlewea By Labeling Detail CUSTOMER NAME: Ramesh, Sunil SYSTEM SIZE: 8.320 kWdc-stc SYSTEM RATING: X.xxx kWac-field 477 Valley Way SITE ADDRESS: 11441 S Stelling Road, Cupertino, CA 95014 SunWoflk a Milpitas, CA 95035 MODULE TYPE AND NUMBER: REC Solar REC-260-PE BLK (32) Renewable Energy Prcects (650) 520-9918 AUTHORITY HAVING JURISDICTION: City of Cupertino INVERTER TYPE AND NUMBER: SMA Sunny Boy 7000TL-US (1) CA License No. 920732 (650) 350-4331 fax DATE: 2 November 2014 DRAWING NUMBER: SW.0141.LD.A.01 SCALE: 1:1 (1 inch = 1 inch)