13070201 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21450 VAI AVE CONTRACTOR:SOLARCITY PERMIT NO: 13070201 OWNER'S NAME: WEIMAN LYLE A AND KATHY A 3055 CLEARVIEW WAY DATE ISSUED:07/31/2013 OWNER'S PHONE: SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL❑ COMMERCIALE] License Clas Lic.# (6.37KW) INSTALL 26 ROOF TOP MOUNTED PV PANELS Contractor Date l I hereby affirm that I am licensed under the provisi sof hapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$26000 I have and will maintain Worker's Compensation Insurance,as provided for by ection 3700 of the Labor Code,for the performance of the work for which this APN Number:36205024.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, J costs,and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. r� RE-ROOFS: Signature Date ( All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Scc.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. _T will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505 5533 534. Section 3700 of the Labor Code,for the performance of the work for which this " Owner or authorized agent: Date: permit is issued. s I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance Of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMNIUN17!DEVELCPMENT OEPARTMEN--BUILDING-N;SiCN •CUPERTINO, CAC�U 14-3,�49 ,9300 TORRE AVENUE: A'dS'--777-3228- r-AX .-A081. c U' PERTINO Al"I 4 j 7z- S-.itP-ET ADDRESSC,"7y..1-,-m-'::P L-y CUOS'rAC=MUM D4A `2 -y. 7��O 85 - r16-0 FA✓X STIFIT ADDRESS -T. STkTu, ZIP OwNER-BUILDU O"VE Ac;--N- KC -1,-.-ACTQFL 17CDNm-XCT0'RAGE:-S" u kjLCHM(-T E-ERNION-tPIR -- DEVEL:iPRI :::Tmnor-, cr.."sE- PEC BUS Lf C0,19-AACTOP.14AME LICE,ISE E K "ct:,. YPEC , 0���.A&ro-se- ' Ji �- COMPANYMAIME 656 01(blq� Lev. f ! V,7, L vvo � . " q2jS -777W)6 LECx CONTAN'11*-NAM S'IiRMT ADDU-SS Z!P U.3 rl.*OF SFD or Duplex 7 2viulti-Filmily (N Commercial r.A,9AN i^=-Rf V.M,UtHA y-zS No SOLAR — PANELS n-C-RIC VEhICUE CHARGING STATION ED SOLAR WAT-SR HEAT-.NG FOR SOL4R PAMELS NUMIER;r 7A!jELSfU-1,.-T3 QNLY'. DU-SCRWT1W 26 12 e:-,Cq-JS y B,. m-j immature oe!nw.I�zrit.".,tO cath Ofv`'allowing'-h 3Renl-I-Ict )m appiti-.ution and:he mformation,hov;prov:ded is carica, have-mad"he MscT:pt1cn.)fW,.r4 and witty i-,.s wc;,jr-aw. amu specticriplimoscs gnaturm of Applictint/Ageit OfffCE USE ONLY w yn"D F- G EXJ�HESS �,TA ND A RD LARGE MAJOR PVAPP-2011.jcc revised CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION kAPN: DDRESS: 21450 VAI AVE DATE: 07/31/2013 REVIEWED BY: MELISSA . 362 05 024 BP#: � -7G *VALUATION: 1$26,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RE USE: PERMIT TYPE: A WORK 6. W INSTALL 26 ROOF TOP MOUNTED PV PANELS SCOPE Tech, Flan Clacck Plaunh, Pari C`hec°l, Flee. Nan Ghee% Tech. Perlijil Fee" 11111mb. Permit l'CE.': r1cc. Permit hee: Other alech. hish. Other Plunib hasp, 0 Other Elec.Insp. Aleeh,Inspz Fee: Phrmb, hup, l ee: Elec.Insp,fee" NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc . These.fees are based on the prelimina information available and are only an estimate. Contact the De t or addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/121 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00I1 # Alternative Energy System Suppl.PC Fee: e) Reg. 0 OT 0.0 1 hrs $0.00 $229.00 1PHOTOVRE5 I Photovoltaic System A PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Fee:) Reg. Q OT 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: Administrative Fee: 0 Work Without Permit? 0 Yes (D No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential G 71-ave/Documentation Fees. Building or Structure 0 Strom Motion Fee: IBSEISMICR $2.60 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $2.00 SUBTOTALS: $4.60 $229.00 TOTA-Ll FEE: $233.60 Revised: 07/01/2013 \v i i ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTEII) TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE INSTALLING 26—ROOF TOP FLUSH—MOUNTED PANELS 6.37K � t r "��. N CONC CONCRETE HAZARDS PER ART. 690.17. DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE I ECC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY APN:362-05-024 (E) EXISTING PHASE AND SYSTEM PER ART, 210.5. x f a� } EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY—RECOGNIZED TESTING GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. ' GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(6) j E r* 4L-`:.-' n , u; I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER A Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690.31(E). kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY ' MIN MINIMUM UL LISTING. C'#jFCk ED (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE NTS NOT TO SCALE UL—LISTED LOCATION PROVIDED BY THE jo "° �``` 4r �i l ��� I ������ �¢� QATrE OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING PL PROPERTY LINE HARDWARE. tb'U.,i spa 114€3 lu 1 € AN P01 POINT OF INTERCONNECTION 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE ,, , I,� , ��� SRI s � efd �r1=� 4�i°, = rn` I +- e _ � � PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS AND l p r e 7i pia �7��a'.� t@€3e SCH SCHEDULE GROUNDED AT THE MAIN ELECTRIC PANEL. .is r" t ..r t r i C f aONO I sk € �t ,a r €.0 SS STAINLESS STEEL 9. THE DC GROUNDING ELECTRODE CONDUCTOR STC STANDARD TESTING CONDITIONS SHALL BE SIZED ACCORDING TO ART. 250.166(B) & BY TYP TYPICAL 690.47. UPS UNINTERRUPTIBLE POWER SUPPLY r V VOLT R3 Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT1-3t-52K, W WATT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET r PV2 SITE PLAN PV3 STRUCTURAL VIEWS * " •� PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES • MI - k • PV5 THREE LINE DIAGRAM PV6 ELECTRICAL CALCULATIONS 1. THIS SYSTEM IS GRID—INTERTIED VIA A CA # 888104 Cutsheets Attached UL—LISTED POWER—CONDITIONING INVERTER. C-46, C-10 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. • a�� 4. ALL WORK TO BE DONE TO THE 2010 f� MODULE GROUNDING METHOD: SLEEKMOUNT CALIFORNIA BUILDING CODE. ` 5. ALL ELECTRICAL WORK SHALL COMPLY WITH . • ! REV BY DATE COMMENTS AHJ: Cupertino THE 2008 NATIONAL ELECTRIC CODE AS AMENDED - ., REV A NAME 7/26/2013 COMMENTS BY THE 2010 CALIFORNIA ELECTRIC CODE. • UTILITY: Pacific Gas and Electric Company (PG&E) ;a _ PREMISE OWNER: µDESCRIPTION: DESIGN: �► CONFIDENTIAL— THE CONTAINED SHALLOT BERMATION USED FOR THE TN JOB HE JB-9501913 00 WEIMAN, LYLE WEIMAN RESIDENCE Elliot Law BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ���SolarCity. NOR SHALL IT BE DISCLOSED IN MHOLE OR IN Comp Mount Type C 21450 VAI AVE 6.37 KW PV Array �� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (26) Advantage Module 3955 t e, CA May SOLARCIIY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San 1028 CA 94402 INVERTER: T.1(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE AURORA PVI-4.2—OUTD—S—US—Z 4084464143 COVER SHEET PV 1 7/26/2013 (888)—SOL—CITY(765-2489)www.solarcity.com i I PITCH: 18 ARRAY PITCH:18 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories I I A ' PLAM 21450 Val Ave ; Front Of House P1,ANNtNG I)l " ° I I I I � Inv n- e a e TOTAL ARRAY AREA(SF):467 n-Locked Gated TOTAL ROOF AREA (SF):2390 TOTAL ARRAY AREA IS a 16 PERCENT OF TOTAL ROOF AREA LEGEND MP1A r � (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO TR TU PITCH CHANGE I°� & WARNING LABELS ANGE ` JB Dc ° DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS B '' JUNCTION BOX A PV3 ry PV3 ' ❑c DC COMBINER BOX & WARNING / � - DISTRIBUTION PANEL & WARNING - """ LOAD CENTER & WARNING LABELS rN DEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE --- INTERIOR EQUIPMENT SITE PLAN N Scale:1/16" = 1' w E 01' 16' 32' S JB-9501913 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL– THE INFORMATION HEREIN JOB NUMBER: ®�•���o CONTAINED SHALL NOT BE USED FOR THE WEIMAN LYLE WEIMAN RESIDENCE Elliot Law -- BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21450 VAI AVE 6.37 KW PV Array '��� SolarCity, PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (26) Advantage ModulePAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-4.2-OUTD-S-US-Z 4084464143 SITE PLAN PV 2 7/26/2013 (888)—SOL—CITY(765-2489)www,solorcity.com i MODULE IS 4" OFF ROOF DECK MODULE IS 4" OFF S1 ROOF DECK (E) 2x6 (E) 20 (E) 20 (E) 2x6 S1 0118' 1'— (E) LBW (E) LBW 7'-7" (E) LBW (E) LBW SIDE VIEW OF M P 1 B RAFTER: (E) 2x4 @ 24" O.C. 1 — B NTS CEILING JOIST: (E) 2x6 @ 24" O.C. SIDE VIEW OF MP1A RAFTER: (E) 2x4, 2X6 @ 24 O.C. RIDGE: (E) 1x6 RIDGE BOARD A CEILING JOIST: (E) 2x6 @ 16" O.C. MAX SPAN: 7—5 NTS MAX SPAN: 7'-7" MAX STANDOFF DISTANCE: 72" O.C. MAX STANDOFF DISTANCE: 72" O.C. PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C --- ---- ---- ------- ZEP FLASHING C (3) (3) INSERT FLASHING. f w I i (E) COMP. SHINGLE (4) PLACE MOUNT (1) (E) ROOF DECKING (2) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (6) (2-1/2" EMBED,EMBED, MIN) BOLT & WASHERS, (E) RAFTER STANDOFF SScale: 1 1/2" = 1' J B-9501913 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE WEIMAN, LYLE WEIMAN RESIDENCE Elliot Law ,�,; BENEFIT OF ANYONE EXCEPT SOLARCITY INC„ MOUNTING SYSTEM: '/e /� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 21450 VAI AVE 6.37 KW PV Array ®�N �ty PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION PATH THE SALE AND USE OF THE RESPECTIVE (26) Advantage Module 3055 geardew Way PACE NAME: SHEET: REV: DATE: San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCiTY INC. POWER—ONE AURORA PVI-4.2—OUTD—S—US—Z 4084464143 STRUCTURAL VIEWS PV 3 7/26/2013 (888)—SOL—CITY(765-2489)www.solorcity.corn UPLIFT CALCULATI®NS Structural Design Software ProjectInformation Risk Category II PV System Type SolarCity SleekMount"' Comp Roof Comp Roof #of Layers 1 Roof Slope 180 Rafter Spacing 24"O.C. PV Module Orientation Landscape and Portrait Total Area of Array. 457 sf PV Module Width 3.2 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C Ground/Roof Snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 Surrounding Roof Snow 0.0 pst ASCE Eq:7.4-1 Roof Snow Over PV Modules 0.0 psf ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 85 mph Fig.6-1 Exposure Category C Section 6.5.6.3` Roof Style Gable Roof Fig.6-11BJC/D-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area 1 Module A 1 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor `` Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1:0 Table 6-1 Velocity Pressure qh qh =0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 14.9 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-11BJC(D-14q(B Ext.Pressure Coefficient Down GCo Down 0.45'' Fig.6-118/C/o-10/0 Design Wind Pressure P p=gh GC Equation 6-22 Wind Pressure Up Kup) =13.0 psf Wind Pressure Down down 10.0 Psf Allowable Attachment Spacings In X-Direction Y-Direction Max Allowable Foot Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" TVA Max Standoff Tributary Area TribCL 19 sf PV Assembly Dead Load WPV 3 psf Net Wind Uplift at Attachment TCL -220 lbsCl"'-"' Uplift Capacity of Attachment Tallow 607 lbs Attachment Demand/Capacity DCRLand 34.6a/o Max Allowable Foot Spacing Portrait 72" 65" Max Allowable Cantilever Portrait 24" NA Max Standoff Tributary Area TribCP 32 sf PV Assembly Dead Load WPV 3 psf Net Wind Uplift at Attachment TCP -367 lbs Uplift Capacity of Attachment Tallow 637 lbs Attachment Demand/CapadtV DCRPort 57.6% JB-9501913 0 0 PREMISE OHNER; DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE WEIMAN, LYLE WEIMAN RESIDENCE Elliot Law �, �;BENEFlT OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM: ',gSolarCily. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type c 21450 VAI AVE 6,37 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE (26) Advantage Module 3055 gearNew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV; DATE: San Mateo,CA 94402 INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. POWER—ONE # AURORA PVI-4.2—OUTD—S—US—Z 4084464143 UPLIFT CALCULATIONS PV 4 7/26/2013 (888)-SOL-CITY(765-2489)www.solarcity.com i I GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: CHALLENGER Inv 1: DC Ungrounded INV 1 —(1 )POWER-ONE # AURORA PVI-4.2-OUTD-S-US-Z LABEL: A —(26)Advantage Module CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:1007035587 Inverter; 420OW, 240V, 96% PV Module; 245W, 221.6W PTC, Poly, 60 Cell, Black Frame, White Bcksht, EP Enable-46, C-10 INV 2 Voc: 37.8 Vpmox: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 125A MAIN SERVICE PANEL E� 125/2P MAIN CIRCUIT BREAKER Inverter 1 IND CUTLER-HAMMER 1 DO NOT ADJUST MIN.ACTIVATION V TAGE 125A/2P Disconnect 3 POWER-ONE DC+ AURORA PVI-4.2-OUTD-S-US-Z DC_ 1 String(s)Of 13 On MP 1 (E) LOADS L1 zaov -------- ------------ —EG-----------------� �• GFP/GFCI DC+ • N DC I 2 DO NOT ADJUST MIN.ACTIVATION V TAGE 25A/2P ---- GN ------------------------------------- EGG __ DC+ DC+ m A GEC O �_ OC_ 1 String(s)Of 13 On P 1 Iry l� EGC -- ————————————————————— --—————————— —E—--——————————— —---� I (1)Conduit Kit; 3/4'EMT N I EGC/GEC z z c� GEC TO 120/240V SINGLE PHASE I UTILITY SERVICE I I I I I I PERJW `r POI (i)CUTLER—HAMMER I BQC2252115 PV BACKFEED BREAKER A (1)CUTLER—HAMMER j DG221URB Breaker; 15A/iP-25A/2P-15A/1P, 2 Spaces, QuadplexDisconnect; 30A, 240Vac, Non—Fusible,NEMA 3R —(1) AC DC CUTLER—HAMMER/DG030N8 Ground/Neutrol Kit; 30A, General Duty(DG) i)AWG 110, THWN-2, Black (2)AWG#10, PV HIRE,Black Voc =491,4 VDC Isc =8,63 ADC OISS(1)AWG#10, THYM-2, Red O LRL(1)AWG#10, Solid Bore Copper EGC Vmp =399.1 VDC Imp=8.17 ADC 1111 (1)AWG#10,THWN-2, White NEUTRAL Vmp =240 VAC Imp 20 AAC , (1)ConduitKii;,3/4',EMT, , ,, ,, ,,, , , , ,, , , ,, , ,,, , , ,, ,, , , , , ,,,, , , (1)AWG/$,,TFtHN-?,,Green, , EGC/GEC (1,)Condu(t,Kit.V47 EMT, , , , , , , , , (2)AWG%10, PV WIRE,Black Vac =491.4 VDC Isc =8,63 ADC O (1)AWG#10, Solid Bare Copper EGC Vmp =399.1 VDC Imp=8.17 ADC (1)Conduit Kit;.3/47,EMT. . .. .. . . .. .... . . . . ... . . . . . .. . . . . ..... . CONJB-9501913 0 0 PREMISE OMER: DESCMPRON: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE WEIMAN, LYLE WEIMAN RESIDENCE Elliot Law SolarCity. NOR SH OF ANYONE EXCEPT SOLWHOLE INC„ MWNIING SYSTEM: NOR SHALL IT BE DISCLOSED IN H110LE OR IN Comp Mount Type C 21450 VAI AVE 6,37 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Cleorvlew Way THE SALE AND USE OF THE RESPECTIVE (26) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV DATE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. 40844641 43 PV 5 7/26/2013 8'(650) CITY(7 5 F89)w 638-102y POWER—ONE AURORA PVI-4.2—OUTD—S—US—Z THREE LINE DIAGRAM (8a8).-SOL-CITY www.sdarcit.com 1. Conductor Sizing per Art deg. ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125% of continuous � current. b, Conductor must have (after corrections for conditions of use) >= Module: 26 Advantage Module 223 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 continuous current per Table 310.16. Inverter 1: 1 Power-One PVI-4.2-S 0.96 4600 5566.08 Vdrop= Imp) 2*Length)* Resistance / (Vmp) Module: Imp(A) Max.Length ft Wire Inverter 2: String: 8.17 85 AWG 10 at Max Ave Hi:84 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Module: Vdrop= 8.17 -170 *0.001240hms / 364.01404 0.47 Ampacity of wire derated for conditions of termination must be >= Inverter 3: Branch: 1 8.17 0 1 AWG 10 at Max Ave Hi:84 degF continuous current*1.25. All string terminations are rated at 90' C. Module: Vdrop= (8.17 0 0.001240hms) / 364.01404 0 D ------------------------------------------ Inverter 4: Total voltage dro in DC voltage drl ia_ con ductors= 0.47 1 1 Inverter: 8.17 15 AW _10 at 240V 2. OCP Sizing per Art 690.8(B)(1) Vdrop= (8,17 30 0.0012 Ohms) 240 V 0.12255 a. Round up to next size per Art 240.4(6) Total: 26 Modules Total Inv Pwr: 4600 5566.08 PTC Combined: 0 0 at 240V - - 0 _______________ Photovoltaic Module Electrical Specifications: Total STC:l 6370 Vdrop= (0 *0 Ohms) / 240 V 0 3. Conductor Sizing per Art 690.8(A) Voc: 37.8 V deg F deg C a. Conductor must have 30 deg. C ampacity >= 125% of continuous Vmp: 30.7 V Record Low Temp: 17 tPI Total voltage drop in AC conductors= 0.12 current. Isc: 8.63 A Max Average Hi Temp: 84 Total voltage drop in AC and DC conductors= F0_.6 __] Imp: 8.17 A Record Hi Temp: 1 b. Conductor must have (after corrections for conditions of use) >= Tvoc: -0.12852 V/deg C Tisc:l 5.681 mA/deg C continuous current per Table 310,15(B)(16). String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 0 Voc Correction Factor: Power-One PVI-4.2-5 1 strings per branch 1 1 strings per branch 2 c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= 13 Inverter Min Vdc Input: 120 Advantage Module Min Vmp at Max Temp: 364. 13 modules per series string 13 modules per series string p y 01 Voc= 491.4 Voc= 491.4 V Voc= 491.4 V continuous current*1.25. All branch terminations are rated at 75' CMax Voc at Min Temp: 546.54 Vmp= 399.1 Inverter Max Vdc Input: 600 Vmp= 399.1 V Vmp= 399.1 V min. Isc= 8.63 Isc= 8.63 A Isc= 8.63 A ------------------------------------------ Imp= 8.17 Max String Size: 14Imp= 8.17 A Imp= 8.17 A 4. OCP Sizing Icont= 10.79 Art 690.8(A)(1) 1-way wire length: 85 Icont= 10.79 A Icont= 10.79 A Art 690.8(A)(1) a. Round up to next size per Art 240.4(B) 1.a Conductor:I AWG_10 PV Wire 2.a Conductor 1: AWG-10 IPVVVire __________________________________________ Conductor 2: 1 AWG-10 PV Wire 5. Conductor Sizing per Art 690.8(A) Icont*1.25=(Amps) 13.48 Conductor 1 Conductor a. Conductor must have 30 deg. C ampacity >= 125% of continuous 30 deg C ampacity= 40 (cont*1.25=(Amps) 13.48 13.48 1.b (cont=(Amps) 10.79 30 deg C ampacity= 40 40 Current. Start ampacity 40 2.b Icont=(Amps) 10.79 10.79 Temperature derate(%=F) 0.71 Start ampacity 40 40 b. Conductor must have (after corrections for conditions of use) >= Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.76 0.76 continuous current per Table 310.15(6)(16). Derated ampacity 28.4 F Conduit fill derate(%_#) 0.8 0.8 1.c Derated ampacity 1 24.32 24.:32:1 1 c. Evaluate conductor temperature at terminations per Art 110.14(C). (cont*1.25=(Amps) 13.48 2.c Term 1 Term 2 Ampacity of wire derated for conditions of termination must be >= Ampacity 4o Temp table 75degC 75degC continuous current*1.25. All inverter output terminations are rated at 1.d Icont*1.25=(Amps) 13.48 Icmpacity (Amps) 13.48 13.48 75' C. OCP Size= 15 Ampacity 35 35 ------------------------------------------- Inverter Type AOutput 2.d OCP Size 1 151 15 6. OCP Sizing Power-One PVI-4.2-S 1 way wire length: 10 It Combined Inverter Output a. Round up to next size per Art 240.4(B) Icont 1 20 JA Art690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 25 Art 690.8(8)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 25 Art 240.6 A (cont=#of inverters*max inverter current Art 690.8(A)(1) 7. Conductor Sizing per Art 690.8(A) (cont=(Amps) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 w r '-t " a. Conductor must have 30 deg. C ampacity >= 125% of continuous 4.a Icont*1.25=(Amps) Art 690)8(6)(1) ` Icont*1.25=(Amps) 25 OCP size= Aft 240.6(A) current. 30 deg C ampacity= 40 3.c Icont=(Amps) 20 4.b Conductor: THWN-2 at 90 dei C :Table 310.16 b. Conductor must have (after corrections for conditions of use) >= Start ampacity 40 Icont*1.25=(Amps) 30 deg C ampacity Temperature derate(%=F) 0.91 = - continuous current per Table 310.15(6)(16). 4.c Icont=(Amps) Conduit fill derate c. Evaluate conductor temperature at terminations per Art 110.14(C). Derated ampacity 36.4 start ampacity 3.d Icont*1.25=(Amps) 25 Temperature derate(%=F) Ampacity of wire derated for conditions of termination must be >= Ampacity 35 Conduit fill derate continuous current*1,25. All inverter output terminations are rated at Derated ampacity 75' C min. 4.d Icont*1.25=(Amps) Ampacity J B-9 5 01913 0 O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE WEIMAN, LYLE WEIMAN RESIDENCE Elliot Law NORBENEFITSH OF ANYONE EXCEPT SOI WHOLE INC., MOUNTING SYSTEM: SolarCity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 21450 VAI AVE 6.37 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES. CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION PATH 3055 gearNew Way THE SALE AND USE THE RESPECTIVE (26) Advantage Module SOLARCITY EQUIPMENTT,, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 INVERTER: T:(650)638-1028 F-.(650)638-1029 PERMISSION of soLARCITY INC. POWER-ONE AURORA PVI-4.2-OUTD-S-US-Z 4084464143 ELECTRICAL CALCULATIONS PV 6 7/26/2013 (888)-SOL-CITY(765-2489)www,eolorclty.coro i E= Label Location: Label Location: Label Location: NON (C) (AC) (POI) mom (POI) Per Code: �' Per Code: Per Code: CA Fire Guidelines CEC 690.54 CEC 690.64.B.4 Label Location: ® (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: Label Location: (AC) (POI) (DC) (INV) ® Per Code: ®® d min CEC 690.35(F) Label Location: TO BE USED WHEN (DC)(INV) INVERTER IS ®® d Per Code: UNGROUNDED ®� CEC 690.53 Label Location: r (AC) (POI) ® Per Code: CEC 690.17 ® r Label Location: ® (DC) (CB) Per Code: ® ® a® CEC 690.17 Label Location: (POI) Per Code: ®®® min CEC 690.64.B.7 Label Location: ��; 9 �� ' sl¢U Label Location: f e e (DC)(INV) , (POI) Per Code: ®� ® Per Code: CEC 690.5(C) ®� . �n ® CEC 690.54; CEC 690.17 a i Label Location: (AC): AC Disconnect (AC) (POI) (C): Conduit Per Code: ' CEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit ael, Label Location: (INV): Inverter With Integrated DC Disconnect (D) (POI) (LC): Load Center Per Code: (M): Utility Meter CEC 690.64.B.4 � (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ��w��I 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED i San Mateo,CA 99902 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set ,„► T:(650)636-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I, SolarCi-Ey. (888)-SOL-CIfY(765-2989)wwwsolarcty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC, i i i i The SolarCity SleekMount hardware solution ®Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules ; aesthetics while minimizing roof disruption and � �; Drill Pilot Hole of Proper Diameter for ®Interlock and grounding devices in system UL � � labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute ®Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant as"Grounding and Bonding System" to a more visually appealing system.SleekMount; Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with ®Ground Zep UL and ETL listed to UL 467 as '' layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the 4; Place Comp Mount centered need for rail and reducing the number of ®Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition ®Anodized components for corrosion resistance 5= Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer, system,allowing for minimal roof disturbance. ®Applicable for vent spanning functions ¢; Secure Leveling Foot to the Comp Mount using machine Screw Place module Components I A. 5/16"Machine Screw Q� Leveling Foot Lag Screw L) Comp Mount i Comp Mount Flashing � l s 0 i v I � 0 I � i QOOMVq)B ® r ONUL LISTED January 2013 © January 2013 i i i rIp ..:J ff _.�zrr�of f,,r rr',,,.,?.✓`�' Itr - /r ll?t r< fry 1j ..,rYlr'f/ i�rr`F ,d'r -'�f f�`.rra= ✓f%'rf f!/ fP 7rk �la'P r r r S,r� ��� r 11( r '� rf jfi� 11 fl�rfl 'filr f`r,!r.'. 1 ,&I7rIr�r?•frr' r of.rrr r�f c t r,, 11 t r '.1?ff7 , x~'- l wry rf/��'ir} rr i,±� i Pei yerm#0—. t ? r tr'r?Y r yet rr r•'vf + ;1 lj P f 1 r r r� r + rfr^"ij r,:✓ a 9 r Renewable Energy Solutions AURORA Nominal Output Power W j 3000 3600 4200 Rated Grid AC Voltage _ V 208 240 3300'* i 3600 1 4000** 1 4000'* 4200 4600** 1 4600`* Maximum Output Power W 3000 � 3300** - _ g - 1 277 208_ zoo -i 277 i 208 _ 240 _277 " r r� InputSide(DC) �• f 1 �r Number of Independent MPPT Channels 2 2 2 _ � _- rl rFr f r�- Maximum Usable Power for Each Channel W 2000 3000 _ 3000 rariYl Sart-UpVoltage(Vstart)ge(Vmax) _ V ( 200(adj0120-350) 200(adj.120-350) 1� _ - -ute Maximum 600 600 200(adj.120-350) OlePatnefMPPT Voltage RangeMPPTVoltageRange-- - I- V- 4_ OJxVsOtart0580 12053- 140530. - _ - 0 - �° p g 0.7xVstarh580 0.7xVstatt-580 Maximum Current pdcmax)for both MPPTinParallel�l A 20 32 _ 32__ _ Maximum Usable Current erChannel A 10 16 16 P Maximum Short Circuit Current Limit per Channel I A I 125 20 20 Nu in ber ofWire Landing Terminals Per Channel j _ 2 Pairs(I on-S version) 2Pairs(Ion-Sversion) _..) 2Pairs(Ion-Sversion) Arra Wiring Termination f y g Terminal block,Pressure Clamp,AWG10-AWG4 Output Side(AC) < 't „,.,,,. Grid ConnectionType 013W Split- Split- 10/2W Adjustable Voltage Range(Vmin•Vmax) V 183/228 211-264 2lit 44304 1833 8 211-264 244-304 183-228 0/3W 0/3W 1012W i 10/2W 60 j 211-264 � 244-304 Grid Frequency Hz 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 ' Maximum_Current(lacmax) A� 14.5 14.5 12 1 17.2 16 16 20 20 20 > Power Factor -- >0.995 >0.995 >0.995 _ The most Common residentialInverterIsthe!d'ealsize for anavera e- g Total Harmonic Distortion At Rated Power % <2 <2 _ _ <2 sized family home This,family of single-phase string inverter. �_' Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG10-AWG4 complements the typical number of toofto solar panels,allowing, Protection Devices home-owners to ethe"most=effident energy harvesting for thInput g gy g e Reverse Polarity Protection Yes ( Yes Yes sizeO theproperty.Th15rU =edOUttlOOrinverterhasbeentleSi designed Over-Voltage Protection Type V_a_ristor,2for_eachchannel Varistor,2 for each channel j Varistor,2 for each channel f : gg g PV Array Ground Fault_Detection_ Pre start-up Riso and dynamicGFDI(Requires Floating Arrays) as d completelySealed Unitt0 Withstand the harshest environmental P Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 g _I requirements - requirements Meets UL1741/IEE1547 n Output __ conditions. Anti-Islandin Protection requirements i -- -. -.- -- - -- - r Over-Voltage Protection Te � Varistor,2 Li•Lz/Li-G) i Vanstor,2 Lt-L,/Li-G) �' Varistor,2 Lt-L,/ ,One of the key benefits of the,Uno family of single-phase inverters 1 Maximum AC OCPD Rating - A , 20 20 15 25 - 20 20 1 2s _ 25 i _ 25 Is the dual Input section to process two stHngs with independent Efficiency Maximum Efficiency % 96.9 1 97 97 - MPPT especially useful for rooftop installations with two different cECEfficlency 96 96 96 orientations{ie East and West),The high speed MPPT offers real-time Operating Performance _ r Stand-by Consumption _ _ Wuu <8 <8 <8 power tracking and Improved energy harvesting. x i Nighttime consumption Wuas <0.6 <0.6 <0.6 Communication- The 16 characters x 2lines LCD display The transformerless operation gives the highest efficiency of up to Remote Monitoring(1xRS485 incl,) AURORA -UNNERSAL(opt.) The wide input voltage range makes the inverter suitable t0 y wired Local Monitoring(lxRS48S incl.) PVI-USB-RS48S_232(opt),PVI-DESKTOP(opt.) M Local -DES 0 o t.with - D 0 ODULE(opt.) WirelessI PVI KTP h PVI RAI M low power installations with reduced string size, Environmental I ' -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with Ambient Air Operating Temperature Range °F(°C) derating above 131(55) derating above 131(55) J derating above 113(45) r Ambient Air Storage Temperature Range °F(°C) j -40 to 176(-40 to+80) -40 to 176(-40 to+80) ! -40 to 176(-40 to+80) p 9 p 9 Relative Humidity - %RH 1 0-100 condensing 0-100 condensing 0.100 condensing - / Acoustic Noise Emission Level db(A)@lm <50 <50 <so Maximum OperatingAltitude wdhoutDeratin 1 ft(m) 65602000 65602000 � ;,,65 2000 a: f Mechanicals Specifications rt rr / t P l _r Enclosure rating NEMA 4X NEMA 4X C aNEMA4X r' Cooling i _ Natural Convection �_ __ Natural Convection NAural'Convection e Each inverteris Seton specific grid codes which can be selected in the field, Dimensions(H xwx n) in(mm) 33.8x12.8_xs.7(859x32sx222)-SVersidn m 5inglephaseOUtput Weight _ _ Ib/(kg) <47.3(21.3)-Sversion <47.3(21.3)-Sversion l {47.3,(21.3)-Sversion Mounting System Wall bracket Wall bracket wall bracket ' e Dual input sections with independent MPPT,allows optimal energy harvesting from two sub,arrays oriented in -- - Trade size KOs:(tea x 1/21 and ! Trade size KOs:(tea x 1/21 and grade"size KOs:(Zea x 1/21 and differenYdirectlons Conduit Connections*** (2eax1-1/4,3places side,front, (2eax1-1/4',3 places side,front, (2ea it 1-1/4,3 places side,front, e'Wide Input range ' rear) rear) rear) : p 9 DC Switch Rating{Per Contact) AN 25/600 25/600 25/600 e High speed and precise MPPT algorithm for real time power tracking and Improved energy harvesting Safety s a es _f a ssTran-forse Isolation Level Tran form rl s (Floating Array) Tran f rm rle (Floating Array) m fless(Floating Array) ' �.,,Flatefficiencyn rpCUNeS enand Thigh t poweCy at all output levels enSUring consistent and stable performance aCrOSS Safety and EMC Standard _ UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 I UL 1741,CSA-C22.2 N.107.1-01 the entire input voltageand.OUtpUYpoWel`range safety Approval ;. CSA,, cCSA,, ,CSA°, Outdoor enclosure for unrestricted use under`any environmental conditions warranty Standard Warranty years 10 10 l 10 Integrated DC disconnect switch in compliance with infemational Standards(-S Version) Extended ears 15&20 y y 15&20 15&20 is-485 communication interface(forconnection to laptop ordatalogger) Available Models Compatible sanaard-withoutocswiahandwiringsox ! PVI-3.0-OUTD-US i PVI-3.6-OUTo-US PVI-4.2-OUTD-Us p ` With DC Switch and Wiring Box PVI-3.0-OUTD-S-US j PVI-3.6-OUTD-S-US 1 PVI-4.2-0_UTD-S-US _ " - All dataissubjacttuchangewithout notice Capability enabled at nominal AC voltage and with sufficient DC poweravailable •'•When equipped wtth optbnal DC Swkch andwidn9 Box I I I i i Lf1 �>11 CSA INTERNATIONAL Certificate s Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 3 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA j Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. icp p 2o�i-�-Eem�a�ac� Issued by: Rob Hempstock,AScT. C US f PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- ! OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix:1 or the Descriptive Report. f f E APPLICABLE REQUIREMENTS i CSA-C22.2 No.107.1-01 - General Use Power Supplies E UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment $ } for Use With Distributed Energy Resources(January 28,2010) DQD 507 Rev.2009-09-01 Page.1 i i i i i I i i SolarCity Advantage Module Electrical Parameters at Standard Test Conditions(STC) The SolarCity Advantage module represents a 60 Cell Power Output Pmax W 245 ZEP enabled module.The values shown are the maxium Power Output Tolerances APmax W -0/+5 potential values from SolarCity's portfolio of CEC Module Efficiency rim % 15.23 approved and UL listed modules.Modules will have a Maximum Power Voltage Vmp V 30.7 minimum 10 year warranty.The module installed will be Maximum Power Current Impp A 8.17 one of the following: Open-circuit voltage Ivoc V 37.8 Short-circuit current Isc A 8.63 YL245P-29b:UL File Number E320066 Trina PA05.18 245W: UL FileNumberE306515 Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance IOOOW/m',Cell Temperature 25*C). Electrical Parameters at Nominal Operating Cell Temperature (NOCT) Power Output Pmax W 178 Voltage at Pmax Vmpp V 27.8 Current at Pmax Impp A 6.54 Open-circuit voltage Voc V 34.5 Short-circuit current Isc A 7.08 NOCT:Irradiance at 800W/m',Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y %/°C -0.45 Temperature coefficient of Voc (3Voc %/°C -0.34 Temperature coefficient of Isc alsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/anodized black Weight 45.2 lbs(20.5 kg) e.'; tY r & j I i I