Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
13080133 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10950 STEVENS CANYON RD CONTRAC'T'OR:SOLARCVrY PERNIIT NO: 13080133
OWNER'S NAME: RA.IESH AND MAN.IUSHA RAMCHANDANI 3055 CLEARVIEW NVAY DATE ISSUED:08/19/2013
ONNINER'S PHONE: 4088353187 SAN MATEO,CA 94402 PHONE NO:(650)638-1028
LICENSED CON'T'RACT R'S DECLARATION
(� ` BUILDING PERMIT INFO: BLDG ELECT PLUMB
License Class (] Lic.# tj F f- -
MECH RESIDENTIAL COMMERCIAL
Contractor Ci
Date ts
hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION: INSTALL 10 ROOFTOP FLUSH MOUNTSOLAR PANELS 2.6
(commencing with Section 7000)of Division 3 of the Business&Professions KW
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to sell=insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance,as provided for by Sq.Ft Floor Area: Valuation:$10000
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued.
APN Number:35601061.00 Occupancy"Type:
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter PERMIT EXPIRES IF WORT{IS NOT STARTED
upon the above mentioned property for inspection purposes. (We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, WITHIN 180 DAYS OF PERMIT ISSUANCE OR
costs,and expenses which may accrue against said City in consequence of the 180 DAYS FROM LAST' CALLED INSPECTION.
granting of this permit. Additionally,the applicant understands and will comply
With all non-point source regulations per the Cupertino Municipal Code,Section
9.18.
Issued by: Date:
Signature 41 Date lq /3
❑ OWNER-BUILDER DECLARATION RE-ROOFS:
All roofs shall be inspected prior to any roofing material being installed.If a roof is
hereby affirm that I am exempt from the Contractor's License Law for one of installed without first obtaining an inspection,1 agree to remove all new materials for
the following two reasons: inspection.
I.as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044, Signature of Applicant: Date:
Business&Professions Code)
L as owner of the property,am exclusively contracting with licensed contractors to
construct the project(Sec.7044,Business&Professions Code). ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
hereby affirm under penalty of perjury one of the following three
declarations: HAZARDOUS MATERIALS DISCLOSURE
1 have and will maintain a Certificate of Consent to self-insure for Worker's I have read the hazardous materials requirements under Chapter 6.95 of the
Compensation,as provided for by Section 3700 of the Labor Code,for the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will maintain
performance of the work for which this permit is issued. compliance with the Cupertino i•4unicipal Code,Chapter 9.12 and the Health&
I have and will maintain Worker's Compensation Insurance,as provided for by Safety Code,Section 25532(a)should I store or handle hazardous material.
Section 3700 of the Labor Code,for the performance of the work for which this Additionally,should I use equipment or devices which emit hazardous air
contaminants as defined by the Bay Area Air Quality Management District I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
I certify that in the performance of the work for which this permit is issued,1 shall Health&Safety Code,Sections 25505,25533,and 25534.
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,I Ow r th0 iz, rt �� ' Gb
become subject to the Worker's Compensation provisions of the Labor Code,I must Date:
forthwith comply with such provisions or this permit shall be deemed revolved.
CONSTRUCTION LENDING AGENCY
APPLICANT CERTIFICATION I hereby affirm that there is a construction lending agency for the performance of work's
I certify that I have read this application and state that the above information is for which this permit is issued(Sec.3097,Civ C.)
correct. I agree to comply with all city and county ordinances and state laws relating Lender's Name _
Io building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save Lender's Address
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the
granting of this permit.Additionally,the applicant understands and will comply ARCHITECT'S DECLARATION
with all non-point source regulations per the Cupertino Municipal Code,Section I understand my plans shall be used as public records.
9.18.
'
ature Date�� l Licensed Professional
Sign
i
I
12 ALTERNATIVE ENERGY PERMIT APPLICATION
COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION
10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 �j
CUPERTfNO (40 8)777-3228• FAX(408)777-3333•building(o)cupertino.org q1
PROJECT ADDRESS ��� (A I`� CU
- APN#
OWNER NAME PHON Au'J �` � ''I .E-MAIL o„ CIn ,n �p 1^tl mat I f ,
STREET ADDRESS f�1�p---�\ ��(n n C(� 1 �n CITY, STATE,ZiPJ„ _ ( V �)FAX 1(��l•I'1 1
U!f '
CONTACT NAME l PHONE r < ) ` r/31 E-MAIL a f ;! ^ 1 ,_ c`
CITY
STREET ADDRESS AT , ZIPS �� a � FAX '
1:1OWNER C3u OWNER-BUILDER ,❑ OWNER AGENT CONTRACTOR / CONTRACTOR AGENT 11 ARCHITECT 1:1ENGINEER ❑ DEVELOPER ❑TENANT
CONTRACTOR NAME LICENSE NUMBER gV s r(� LICENSE TYPE C s� BUS.LIC#
COMPANY NAME + � ` ov E-MAIL FAX
STREET ADDRESS c�' CITY,STATE,ZIP ,(}, �j PHONE
ARCHITECT/ENGINEER NAME LICENSE NUMBER , BUS.LIC#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
USE OF SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN
STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes NO FLOOD ZONE ❑ Yes � N0
SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER:
FORSOL,IRPANEL S: NUMBER OF PANELS/UNITS: `1 o #KILOWATTS: �, !� TOTAL VALUATION.
DESCRIPTION OF WORK
RECEIVED BY:'
By my signature below,1 certify to each of the following: I am the property owner or authorized agent to act on the pro e owner's behalf. I have read this
application and the information I rovided is c rrect. I have read the Description of Work and verify it is accurate. I ree[o comply with all applicable local
ordinances and state laws relating b Iding const u 'on. a thorize representatives of Cupertino to enter the above-i enufif�ied roperty for inspection purposes.
Signature of Applicant/Agent: Date: I 13
SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY
W ❑ OVER-THE-COUNTER -
a
F ❑ EXPRESS
U
U
❑ STANDARD
U .
U
z,, - El LARGE
a i
Q MAJOR
PVApp_2012.doc revised 06/20/12
CITY OF CUPERTINO
FEE ESTIMATOR-BUILDING DIVISION
ADDRESS: 10950 stevens canyon rd DATE: 08/19/2013 REVIEWED BY: mendez
APN: BP#: I "MW 3 VALUATION: 1$10,000
*PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair
PRIMARY PENTAMATION SOLAR-RES
USE: SFD or Duplex PERMIT TYPE:
WORK INSTALL 10 ROOFTOP FLUSH MOUNT SOLAR PANELS 2.6 KW
SCOPE
A,Iech, Plan Checl, Plunih. Plun Check Elec.Plan Crecic
ilet;h. I'err��itFec, Phnnb. Permit Fee: F-lec. Permit Fee:
Other rLlec/r. Tnsp. =F Lj L_
Other Phan!)hasp, Other Elec.Insp.
lllech.Insp,Fee: Plumh, hap. F-,'ce, Elec.Insp.Fee:
NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School
District,eta). These ees are based on the preliminary information available and are only an estimate. Contact the Dept-for addn'l info.
FEE ITEMS (Fee Resolution 11-053 E . 7ff 11112) FEE QTY/FEE MISC ITEMS
Plan Check Fee: $0.00 # Alternative Energy System
Supp/.PC Feer Reg. 0 OT F0,0Th $0.00 $229.00 1PHOTOVREs Photovoltaic System A
PME Plan Check: $0.00
Permit Fee: $0.00
Suppl. Insp.Feer Reg. Q OT 0,0 hrs $0.00
PME Unit Fee: $0.00
PME Permit Fee: $0.00
Construction TC'IT: FT
l dmirlistrat lVC'Fee:
Work Without Permit? Yes (j) No $0.00 E)
Advanced Ptai�ee: $0.00 Select a Non-Residential E)
Building or Structure 0
71-ave/ Dociii enlotiorr F'CeS
Strong Motion Fee: IBSEISMICR $1.00 Select an Administrative Item
Bldg Stds Commission Fee: IBCBSC $1.00
SUBTOTALS:` $2.00 $229.00 TOTAL FEE: $231.00
Revised: 07/01/2013
ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES
A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR '
AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE DED WARNING D E S C R I P TI 0 N: INSTALLING R 0 0 F-TOP ' ACG
POSITION, A SIGN WILL BE PROM P R O J E C T I
BLDG BUILDING OF THE HAZARDS PER ART. 690.17.
CONC CONCRETE 2. EACH UNGROUNDED CONDUCTOR OF THE FLUSH-MOUNTED PANELS (2.6 kW)
DC DIRECT CURRENT ey
MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED
EGC EQUIPMENT GROUNDING CONDUCTOR
BY PHASE AND SYSTEM PER ART. 210,5. 'Y'r � t
(E) EXISTING 3. ANATIONALLY-RECOGNIZED TESTINGFly
EMT ELECTRICAL METALLIC TUBING LABORATORY SHALL LIST ALL EQUIPMENT IN
GALV GALVANIZED COMPLIANCE WITH ART. 110.3. t
GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL
GND GROUND COMPLY WITH ART, 250.97, 250.92(B)
HDG HOT DIPPED GALVANIZED 5, DC CONDUCTORS EITHER DO NOT ENTER COMMUNRY O a " T`O ' Ete' - PLA I�
I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS BUILDING DMSION- UP& I
Imp CURRENT AT MAX POWER OR ENCLOSURES TO THE FIRST ACCESSIBLE DC APPROVED
Isc SHORT CIRCUIT CURRENT r
DISCONNECTING MEANS PER ART. 690,31(E), `Ths"� � �� Ictioos UT kept �t p .�. � � �� "',. _-� ���Orw t� ��
kVA KILOVOLT AMPERE p g y _
6. ALL WIRES SHALL BE PROVIDED WITH STRAIN site during
kW KILOWATT RELIEF AT ALL ENTRY INTO BOXES AS construction, it is u (unlawful to make
LBW LOAD BEARING WALL REQUIRED BY UL LISTING. charges or alterations on s2me, oro deviate
MIN MINIMUM 7, MODULE FRAMES SHALL BE GROUNDED AT THE therefrom, without approval from the Building Official,
(N) NEW UL-LISTED LOCATION PROVIDED BY THE
NTS NOT TO SCALE MANUFACTURER USING UL LISTED GROUNDING e mpia of this plan d specifi
OC ON CENTER HARDWARE. cations HALL NOT
e held to permit or to an approval of the violation
PL PROPERTY LINE 8, MODULE FRAMES, RAIL, AND POSTS SHALL BE any Provisions of any O dinance or State Lai,
POI POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS EFY
PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. ' c>�
SCH SCHEDULE D
9. THE DC GROUNDING ELECTRODE CONDUCTOR _
SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. f�C ` NO,
STC STANDARD TESTING CONDITIONS 250,166(B) & 690.47.
TYP TYPICAL
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
Vmp VOLTAGE AT MAX POWER
Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX
W WATT
3R NEMA 3R, RAINTIGHT
' - PV1 COVER SHEET
PV2 SITE PLAN
PV3 STRUCTURAL VIEWS
PV5 'THR,EE�L
INE DIAGRAM ` '`
LICENSE GENERAL NOTES PV6 'ELtbTRICAL CALCULATIONS
Cutsheets, Aktached ,
CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A
C-46, C-10 UL-LISTED POWER-CONDITIONING INVERTER.
2. THIS SYSTEM HAS NO BATTERIES, NO UPS. � ' I
3, PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND
INVERTER INPUT CIRCUIT ARE UNGROUNDED,
4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED
MODULE GROUNDING METHOD: WEEB 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA
BY DATE COMMENTS
AHJ: Cupertino BUILDING CODE. REV
6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REva NAME 7/9/2013 COMMENTS
2008 NATIONAL ELECTRIC CODE AS AMENDED BY
UTILITY: Pacific Gas and Electric Company (PG&E)
THE 2010 CALIFORNIA ELECTRIC CODE.
* * * *
JB-9501950 0 PREMISE OWNER. DESCRIP11oN; DESIGN: `�!to ey
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �.
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin ��'6��Swarcity.
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNDNG SYSTEM: 10950 STEVENS CANYON RD 2.6 KW PV Arra A
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN SC L-Foot: 1 Lag - Downslope y
PART TO OTHERS OUTSIDE THE RECIPIENTS CUPERTINO, CA 95014
ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES 3055 gearview Way
THE SALE AND USE OF THE RESPECTIVE (10) BenQ # PM250M01-26OW PAGE NAME: SHEEEREV. DAIS Son Mateo,CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T-SOL 636-105 F:9)w 638-1029
PERMISSION OF SOLARCITY INC. SOLAREDGE sE3000A—us 4088353187 COVER SHEET PV 1 7/9/2013 (888)—SOL—CITY(765-2489)www.solarcity.com
I
I
i
I
I
I
Y PITCH: 18 ARRAY PITCH:18
MPI AZIMUTH: 118 ARRAY AZIMUTH: 118 '
MATERIAL:Comp Shingle STORY: 2 Stories
PITCH: 18 ARRAY PITCH:18
MP2 AZIMUTH: 118 ARRAY AZIMUTH: 118
MATERIAL:Comp Shingle STORY: 2 Stories
PITCH: 18 ARRAY PITCH:18
MP3 AZIMUTH: 118 ARRAY AZIMUTH: 118
MATERIAL:Comp Shingle STORY: 2 Stories
nr
�3 Fye
LEGEND
(E) UTILITY METER & WARNING LABEL
P3 Q
a . IS Front
INVERTER W/ INTEGRATED DC DISCO
r- Front Of House & WARNING LABELS
Dc
r -_ © DC DISCONNECT & WARNING LABELS
C ———————————————————————
AC
;Il )11a1, 'I' nr 1
AC DISCONNECT & WARNING LABELS
rk
JUNCTION BOX 01
F ` G
MP2 10950 Stevens Canyon Rd Oc DC COMBINER BOX & WARNING
o
_..
B 0° DISTRIBUTION PANEL & WARNING
¢ LOAD CENTER & WARI G'lz�ABILS,
--——— i
O DEDICATED PV SYSTEM METER
CONDUIT RUN ON EXTERIOR'
CONDUIT RUN ON INTERIOR
GATE/FENCE
INTERIOR EQUIPMENT
A O SITE PLAN
ti
a
Scale: 3/32" = 1'
01' 10' 21' s
c^
JB-9501950 00 PREMISEOHNER; DESCRIPTION: DESIGN: ��,rrli►
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER:
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin SolarCity.
BENEFIT OF ANYONE EXCEPT SOLARCITY INC„ MOUNTING SYSTEM: /�
NOR SHALL IT BE DISCLOSED IN MOLE OR IN SC L—Foot: 1 Lag — Downslope 10950 STEVENS CANYON RD 2.6 KW PV Array
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, CA 95014
ORGANIZATION, EXCEPT IN CONNECTION PATH 3055 CleaNew Way
THE SALE AND USE OF THE RESPECTIVE (10) BenQ # PM250M01-26OW PAGE NAME SHEET: REV: DATE San Mateo,CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F.(650)638-1029
PERMISSION OF SOLARCITY INC. SOLAREDGE SE3o0oA-us 4088353187 SITE PLAN PV 2 7/9/2013 (688)—SOL—CITY(765-2489)www.solarcity.com
I
i
c
I
i
i
1
5„ sl
5"
S1
700
' g'_1»
1'-6' 7'-9"
—6'
(E) LBW (E) LBW
SIDE VIEW 0 F M P 1 RAFTER: (E) 2x8 4 24" O.C. SIDE VIEW OF M P2 RAFTER: (E) 2x8 © 24" O.C.
(:
A NTS CEILING JOIST: (E) 2x6 @ 16" O.C. B NTS CEILING JOIST: (E) 2x6 @ 16" O.C.
RIDGE: (E) 2x12 RIDGE BOARD RIDGE: (E) 2x12 RIDGE BOARD
MAX SPAN: 9'-1" MAX SPAN: 7'-9"
MAX STANDOFF DISTANCE: 72" O.C. MAX STANDOFF DISTANCE: 72" O.C.
SOLAR PANEL INSTALLATION ORDER
ATTACHED WITH MODULE LOCATE RAFTER, MARK HOLE sl 5"
CLAMPS, J"-16 BOLTS, (1) LOCATION, AND DRILL PILOT
AND J" NUT HOLE. =e
SOLARCITY SOLAR RAIL SEAL PILOT HOLE WITH
& BOLT —— _ _ — (4) (2) POLYURETHANE SEALANT.
LEVELING FOOT (3) INSERT L—FOOT FLASHING.
(E) COMP. SHINGLE (1) 1'-6' e
(4) PLACE THE LEVELING FOOT. (E) LBW
L—FOOT FLASHING (2) (5) INSTALL LAG WITHSEALING
(E) ROOF DECKING WASHER. SIDE VIEW OF MP3 RAFTER: (E) 2x8 @ 24" O.C.
A" DIA LAG BOLT (5) C NTS CEILING JOIST: (E) 2x6 @ 16" 0.
C.
RD
(2—j" EMBED, MIN) RIDGE: (E) 2x12 RIDGEA
(E) RAFTER MAX SPAN: 10'-3"
MAX STANDOFF DISTANCE: 72" O.C.
S1 STANDOFF
J B—9501950 0 O PREMISE OWNER: DESCRIPTION: DESIGN:
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER:
CONTAINED SHALT.NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin ,,,,,,S��ar„C��t o
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ►�
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN SC L—Foot: 1Lag — Downslope 10950 STEVENS CANYON RD 2,6 KW PV Array ,
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 95014
ORGANIZATION, EXCEPT IN CONNECTION WITH ' 3055 Georv(ew Way
THE SALE AND USE OF THE RESPECTIVE (10) BenQ # PM250M01_260W PAGE NAME SHEET: REV DATE: San Mateo,CA 94402
SOLARCITY EQUIPMENT,WLTHOUT THE WRITTEN INVERTER: STRUCTURAL VIEWS / / 7(650)638-1028 F:(850)638-1029
PERMISSION of SOLARCITY INC. SOLAREDGE SE3000A—US 4088353187 PV 3 7 9 2013 (888)—SOL—CITY(765-2489)wwwsolardtycom
i
I
I
i
UPLIFT CALCULATIONS
i
i
INPUT VARIABLES CALCULATIONS AND VALUES
Required Variables Design wind pressures based upon:
Mean Roof Height: 26 ASCE 7-05 Chapter 6 Wind Loading
Exposure Category: C Equation 6.5.13.3: Component and Cladding Elements
Basic wind speed(or city in the future): 85 Wind pressure P=qh*Cn*G
Importance factor(1 for residential): 1 6.5.10:Velocity pressure
qh=0.00256*Kz*Kzt*Kd*V^2*1
Roof shape: Pitched From Table 6-3:
Roof Angle(degrees): 18 Kz=0.98
Roof zone: 3
Contiguous sq.feet of array: 17.69 From Figure 6-4:
Kzt=1
Least width of the building: 54.72
Obstructed wind flow? True From Table 6-4:
Kd=0.85
Local Topographical Features
(choose "standard"or refer to pictures right, and below) From figure 6-1:
V=85
Type of hill: None
Hill height(h)(ft): From table 6-1:
Slope of hill(degrees): I
n1
Horizontal distance from hilltop to house(x): From Velocity Pressure Equation
Height from bottom of hill to mean roof height(z): qh=15.41
Design Wind Pressure From Figure 6-19B
P(lbs.per sq.ft.)=qh*Cn*G Cn(uplift)_-3.04
Pd(downforce pressure)= 13.1 Cn(down)=1 `
Pu(uplift pressure)= F 39.81 From 6.5.8.1
G=0.85
Max Tributary Area Feet Inches
Arrays consist of modules in portrait and landscape X(E-W distance between standoffs)= 0 72
BenQ GreenTriplex PM250M01 260W Y(N-S distance between standoffs)= 0 30
Amax(sq.ft.)=0.5*L*X Staggered Penetrations= No
L(length of panel in ft.perpendicular to rail) 5.38 Module Rail Max.Span/Cantilever(in)= 72 23
X= 6
Y= 2,5 Max Uplift Force on a Single Standoff
L= N/A Pmax(lbs.)=Amax*Pu
Amax= 16,12 641.97
Dead Load Calculations Factor of safety=FI*D*NI/Pmax
DL(lbs/sq.ft.)=(Mm+Mh)/(L*W) 5/16 x 4 in, =Lag size and length
984.16 =Capacity(Ibs)of 1 lag(NDS)
L(length of modules) 5.38 1 =NI(number of lags per standoff)
W(width of modules)3,22 1.53 =Factor of safety
Mm(weight of modules)41 Point Load Calculations
Mh(weight of hardware per module)= 8 PL(Ibs)=Amax*DL
DL= 2.83 45.58
JB-9501950 0 O PREMISE 014NER: DESCRIPTION: DESIGN:
JOB
CONFIDENTIAL— THE INFORMATION HEREIN NUMBER:
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin �,�,,SolarCity.
BENEFIT OF ANYONE EXCEPT SOLARCITY INC„ MOUNTING SYSTEM: ►�
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN SC L—Foot: 1 Lag — Downslope 10950 STEVENS CANYON RD 2.6 KW PV Array
PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES CUPERTINO CA 95014
THE SAE AND USEEPT OF INCONNECTION
RESPECTIVEWTM (10) BenQ # PM250M01_26OW 3055 CleaMateo,
A 94402
Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME; SHEET: REY DATE: T:(650)638-1028 F:(650)638-1029
PERMISSION OF SOLARCITY INC. INVERTER:
# SE3000A-US 4088353187 UPLIFT CALCULATIONS PV 4 7/9/2013 (666)-SOL-CITY(765-2489)www.soloreity.com
i
i
i
GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE
CA888104
BOND (N) #8 GEC TO (N) GROUND ROD E 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 —(1 )SOLAREDGE # SE3000A—US LABEL: A —(10)BenQ # PM250M01-26OW #
AT PANEL WITH IRREVERSIBLE CRIMP E 200/2P MAIN CIRCUIT BREAKER Inverter; 3000W, 24OV, 97.5%; w/ZB; SE1000—ZB02—SLV—NA PV Module; 260W, 233.8 PTC, Tyco, 40mm, Black Frame
C-46, C-10
Panel Number:Cutler—Hammer INV 2 Voc: 38 Vpmax: 30.9
Meter Number:1006135571 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
i
MAIN SERVICE PANEL Inverter 1
CUTLER—HAMMER
200A/2P Disconnect z SLAREE
E03000A G S
(E) LOADS A zaov
L1
•
L2 GFP/GFCI
N 1
20A/2P ------------------------------------- —Ecc/ __ DC+ DO+ - -
A ____ GND GEC O DC- 1 Strings)Of 10 On MP 1
DC- ���_�LL_JJJ��,
B GND __ EGC EGO
I
I
N I
I
EGC/GEC
Z Z
c9
-
TO 120/240V
SINGLE PHASE
I
UTILITY SERVICE I
I
I
I
I
I
POI (1)CUTLER-HAMMER#BR220 PV BACKFEED BREAKER A (1)CUTLER-HAMMER#DG321UGB /fj Pv (10)SOLAREDGE#OP300-MV-TYCRM-2NA D�
Breaker, 20Af2P 2 Spaces Disconnect; 30A,24OVac,Non-Fusible,NEMA 1 /`-fj PowerBox; 300% Tyco,DC to DC Converter, ETL Listed
—(1)Ground Rod; /8�x 8,Copper —(1)CUTLER-HAMMER#DG030NB —(10)SE-GNDLUG
Ground/Neutral Kit; 30A, General Duty(DG) Ground Lug; For use with SolorEdge PowerBoxes
� P
�T�(1)AWG#10,THWN-2,Black (2)AWG#10 PV IWRE Black Voc 500 VRC Tsc 15 'ADC
OIst—(1)AWG#10,THWN-2,Red (� (1)AWG#8 Solid Bare Copper EGC Vmp 350 VDC Imp 7.33 ADC
Irl (1)AWG 110,THVM-2,White NEUTRAL Vmp =240 VAC Imp=12.5 AAC .(1)Condwt Kit,,3/4 EMT,, , ,
{ s....... . ...... . .
?HWN72,,Green.. EGC/GEC (1)Conduit,Kit;.3/4' EMT..... .. .. J
J B-9501950 0 O PREMISE OWNER; DESCRIPTION: DESIGN:
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER:
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin SolarCity.
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM; ��
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN SC L—Foot; 1 Lag — Downslope 10950 STEVENS CANYON RD 2,6 KW PV Array
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, CA 95014
ORGANIZATION, EXCEPT IN CONNECTION WITH 3055Clearview Way
THE SALE AND USE OF THE RESPECTIVE (10) BenQ # PM250M01-26OW PAGE NAME SHEET: REV: DATE Son Mateo,CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERRTER, THREE LINE DIAGRAM T.(650)638-1028 F:(650)638-1029
PERMISSION OF SOLARCITY INC. SOLAREDGE SE3000A—US 4088353187 PV 5 7 9 2013 (888)-SGL-CITY(765-2489)www.solarclty.com
l
i
i
1. Conductor Sizing per Art deg.8(A) ELECTRICAL CALCULATIONS
a, Conductor must have 30 deg, C ampacity >= 125% of continuous
current.
i
b. Conductor must have (after corrections for conditions of use) >=
continuous current per Table 310,16.
C. Evaluate conductor temperature at terminations per 110.14(C), Hardware Qty Model Voltage Drop Calculations
Ampacity of wire derated for conditions of termination must be >= Module: 10 BenQ GreenTri lex PM250MO1 260 Vdrop= (Imp) (2*Length) (Resistance) /(Vmp)
continuous current*1.25. All string terminations are rated at 90' C. DC Converter: 10 SolarEd a OP300-MV Inv Power DC W PTC DC W STC Inverter Imp(A) Max.Length(ft) Wire
----------`------`-------`------------- Inverter
A: 1 SE3000A US 240V w Zi Bee 3000 2279.55 2600 Inpui: 8.46 75 AWG_10
2. OCP Sizing per Art 690.8(8)(1) Inverter B: Vdrop= (8.46 *150 *0.00124 Ohms) 282.512 0.48
a. Round up to next size per Art 240.4(8) 3000 2279.55 2600 InverterA Imp(A) Max.Length(ft) Wire
------------------------------------------- Output: 7.33 0 AWG 10
3. Conductor Sizing per Art 690.8(A) Vdrop= (7.33 1 0 1 *0.00124 Ohms) 282.512 0
a. Conductor must have 30 deg. C ampacity >= 125% of continuous Inverter Stringing Inverter B Stringing Comb.Drop Imp(A) Max.Length(ft) Wire
String 1: 10 Modules String 1: Modules 7.33 15 AWG-10
current. String 2: Modules String 2: Modules Vdrop= (7.33 *30 1 *0.0012 Ohms) 0.10995 0
b. Conductor must have (after corrections for conditions of Use) >= Photovoltaic Module Electrical Specifications: Photovoltaic Source Circuit(Modules to PowerBox) Voltage Drop Calculations °F °C
continuous current per Table 310.15(B)(16). BenQ GreenTri lex PM250MOl 260 Voc at Min Temp= 41.02 V Record Low Temp: 32 0
Power(STC)= 260 W Voc= 38 V Max Average High Temp: 82 28
C. Evaluate conductor temperature at terminations per Art 110.14(C). Power(PTC)= 233.8 W Vmp= 38 V
Ampacity of wire derated for conditions of termination must be >= Voc= 38 V Vmp at Max Temp= 28.25 V
continuous current*1.25. All branch terminations are rated at 75' C Vmp= 30.9 V Ise= 8.78 A
Ise= 8.78 A Imp= 8.46 A
min, Imp= 8.46 A Icont= 10.98 A
------------------------------------------ Tvoc= -0.12096 V/deg C
4. OCP Sizing Tvmp= -0.13244 V/deg C AWG 12 Table 310.15(8)(16)
a. Round up to next size per Art 240.4(8) Tisc= 3.5 mA/deg C Ampacity= 30 > 13.72 A
------------------------------------------ Corrected Ampacity= 17.40 A > 1 10.98 A
5. Conductor Sizing per Art 690.8(A) Temperature Derate= 0.58
a. Conductor must have 30 deg. C ampacity >= 125% of continuous Conduit Fill Derate= 1
current. DC Converter Electrical Specifications: Inverter A Input Circuit(PowerBox to Inverter) Unused
SolarEd a OP300-MV String 1
b. Conductor must have (after corrections for conditions of Use) >= Power= 300 W Vmax= 500 V Wire Length 75 Vmax= 500 V Wire Length 0
continuous current per Table 310.15(B)(16). Efficiency Factor= 0.987 Vmp= 350 V Vmp= 350 V
Vmin_input= 5 V Imax= 15 A Imax= 15.00 A
c, Evaluate conductor temperature at terminations per Art 110.14(C). Vmaxinput= 60 V Imp= 6.77 A Imp= 6.77 A
Ampacity of wire derated for conditions of termination must be >= Imax_input= 10 A
continuous current*1.25. All inverter output terminations are rated at Vmax output= 500 V AWG 10 90°C:Table 310.15(B)(16) 90 C:Table 310.16
Imax_output= 15 A Ampacity= 40 > 15 A Ampacity= > A
75' C. Corrected Ampacity= 23.20 A > 15 A Corrected Ampacity= A > A
-------------------------------------------
Temperature Derate= 0.58 Temperature Derate=
6. OCP Sizing Conduit Fill Derate= 1 Conduit Fill Derate=
a. Round up to next size per Art 240.4(8) OCP= 20 A OCP= A
7. Conductor Sizing per Art 690.8(A) DC Converter Electrical Specifications: Inverter A Output Circuit Combined Inverter Output Circuit
a. Conductor must have 30 deg. C ampacity >= 125% of continuous SE3000A US(240V) w ZigBee Service Voltage= 240 V Service Voltage= 240 \/ Wire + re
Current. Power= 3000 W Icont= 15 A Wire Length 15 (cont= A re L'eng(�
Vmp input= 350 V
Vmax-input= 500 V AWG 10 90°C:Table 310,15(B)(16) 90 C:Table 310.16
b. Conductor must have (after corrections for conditions of Use) >= Imax input= 10 A Ampacity= 40 > 18.75 A Ampacity=
> A
continuous current per Table 310,15(6)(16). Vmax_output= 240 V =Service Voltage Corrected Ampacity= 36.4 A > 15 A Corrected Ampacity= A > A
[max-output= 15 A =lcont Temperature Derate= 0.91 Temperature Derate=
C. Evaluate conductor temperature at terminations per Art 110.14(C). Conduit Fill Derate= 1 Conduit Fin Derate= ;l
Ampacity of wire derated for conditions of termination must be >= ocP= 20 A ocP= A
continuous current*1.25. All inverter output terminations are rated at
75' C min.
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9501950 00 PREMISE OWNER: DESCRIPTION: DESIGN: *644
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin
NOR SHALL IT"BE"DI CLOSED SOLARCITY INC.,R MOUNTING SYSTEM: 10950 STEVENS CANYON RD 2.6 KW PV Arra '�� SolarCity.
PART TO OTHERS OUTSIDE THE RECIPIENTS SC L-Foot: 1Lag - Downslope Y
ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: CUPERTINO, CA 95014
THE SALE AND USE OF THE RESPECTIVE (1 0) BenQ �ut PM250M01-26OW 3DSs Mateo,an eardew Way
SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN ( ) it PAGE NAME: rPV
ET: REV DAZE: T:(650)638-1028 F:(650)638-1029
PERMISSION OF SOLARCITY INC. ISO AREDGE SE3000A-US 4088353187 ELECTRICAL CALCULATIONS 6 7/9/2013 (888)-SOL-CITY(765-2489)www.solureltycom
1
i
i
I
i
I
I
:
i
I
i
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN:
- Address: 10950 Stevens Canyon Rd
INVERTER AND
AC DISCONNECT
UTILITY
O SERVICE
SOLAR O
O PHOTOVOLTAIC
ON ROOF
PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS
A/C DISCONNECT PER NEC 690.17
- OPERATING VOLTAGE = 240V MAX CURRENT = 12.5 A
-d
JB-9501950 OO PREMISEOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: �_. ■
CONTAINED SHALL NOT BE USED FOR THE RAMCHANDANI, MANJU RAMCHANDANI RESIDENCE Luke Levin ,,,,,So�af�(;�ty.
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �/�
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN SC L—Foot; 1 Lag — Downslope 10950 STEVENS CANYON RD 2.6 KW PV Array
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, CA 95014
ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 gearvlew Way
THE SALE AND USE OF THE RESPECTIVE (10) BenQ # PM250M01-26OW PAGE NAME SHEER REV: DATE San Mateo,CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER. T:(650)638-1028 F:(650)638-1029
PERMISSION OF SOLARCITY INC. SERTER: GE SE3000A—US 4088353187 SITE PLAN PLACARD PV 7 7/9/2013 (988)—SOL—CITY(765-2489)www.solarony.com
i
i
I
mamma=
Label Location: Label Location: 1Label Location:
(C) 4 (AC) (POI) mf, (POI)
Per Code: ®m Per Code: Per Code:
CA Fire Guidelines ®m CEC 690.54 ® ® � e NEC 690.64.B.7
Label Location:
(DC)(INV) r
Per Code:
r f CEC 690.14.C.2 Label Location:
(AC) (POI)
r Label Location:
m (DC) (INV)
Label Location: Per Code:
®®' (DC) (INV) CEC690.35(F)
®® m Per Code:
® ® � TO BE USED WHEN
CEC 690.53
®� r r r W
INVERTER IS
Label Location: r UNGROUNDED
m (AC)(POI)
®® Per Code:
`r CEC 690.17
)! Label Location:
(DC)(CB)
Per Code:
®� CEC 690. Label Location:
17 ���� � � "�d i �k
(POI)
r r r Per Code:
CEC 690.54; CEC 690.17
r
k
Label Location: k
(DC)(INV)
Per Code: ®° a
CEC 690.5(C)
min
C Elm Label Location:
(D) (POI)
Per Code:
CEC 690.64.B.4
ME=
Label Location:
(AC) (POI) (C): Conduit
connect
Per Code: (CB): Combiner Box
CEC 690.14.C.2 (D): Distribution Panel
Label Location: (DC): DC Disconnect
(POI) (IC): Interior Run Conduit
Per Code: (INV): Inverter With Integrated DC Disconnect
e r CEC 690.64.6.4
(LC): Load Center
(M): Utility Meter
(POI): Point of Interconnection
CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FORx'40 r�I 3055 Qeaview way
THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo,CA 94402
IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - CA Label Set '9 T:(650)638-1028 89)w)638d029
EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I� SolarCity. (888)-SOLLiTY(765-2489)wwwsolarcty.com
SOLARCITY EQUIPMENT; WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC.
j
i
i
i
I
The SolarCity L-Foot with Eco-Fasten GreenFasten flashing optimizes strength,performance and aesthetics
while structurally attaching solar panels to composition shingle roofs. This engineered connection uses
Eco-Fasten's patented, IAPMO-certified"green fasten"technology to achieve a watertight seal. 6000
series aluminum offers superb structural and fatigue strength,which in conjunction with anodization
offers excellent corrosion resistance even in coastal environments.
• IAPMO-ES-certified product for waterproofing—Tested in accordance with ICC standards
• Tested in accordance with UL 441—Waterproofing for rooftop penetrations
• Anodized for long term corrosion resistance and best aesthetics
• No shingle cutting required
• Fast and error-proof installation reduces overall impact on roof
• Rail is attached using Stainless Steel Fasteners
Installation Instructions
1. Drill pilot hole in rafter
2. Seal pilot hole with roofing sealant
3. Insert Eco-Fasten flashing under upper layer of shingle
4. Place SolarCity LFoot
5. Install lag with sealing washer
Components '
A. 5/16"Lag Screw �l
B. Stainless Steel+EPDM Sealing Washer 0
C. SolarCity L-FootLo
� f !!►
D. Eco-Fasten Green Fasten Flashing
SolarCiaty
i
i
i
i
solar=@@
T
All our inverters are part of SolarEdge's innovative system — over 97% efficiency and best-in-class reliability. Our fixed-
designed to provide superior performance at a competitive voltage technology ensures the inverter is always working at its
price. The SolarEdge inverter combines a sophisticated, optimal input voltage,regardless of the number of modules or
digital control technology and a one stage,ultra-efficient power environmental conditions.
conversion architecture to achieve superior performance
TECHNICAL DATA
SE3000A-US SE380OA-US SE5000A-US SE6000A-US SE7000A-US
N
5200@208V "Y 5200@208V
Rated AC Power Output 3000 3800 5000 6000@240V 6000@240V W
r
t>r 6000@277V 70009277V
5200@208V 52009208V
�y ..
` r " 3000 3800 5000 6000@240V 6000@240 W
. Max.AC Power Output V
a'u 8000@277V 7000@277V
AC Output Voltage Min.-Nom.-Max. 183-208-229/211-240-264 183-208-229/211-240.284 /244-277-294 Vac
s t1i I r F ke ,is.
AC Frequency Min.-Nom.-Max. 59.3-60-60,5 Hz
Max.Continuous Output Current @208V 14.5 SS.b24 25 25 A
Max.Continuous Output Current 9240V 12.5 16 21 25 25 A
Max.Continuous output Current 0277V - - 18.6 1 22 25 A
GFDI 1 A
Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes
r `
Recommended Max.DC Power*(STC) 3750 4750 8260 7600 87b0 W
" Transformer-less Ungrounded Yes
Max.Input Voltage
500 Vdc
Nom.DC Input Voltage 325 @ 208V/350 @ 240V/400 @ 277V Vdc
Max.Input Current 10 12.5 16 18 18.5 Ado
.t Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600k52 Sensitivity
Maximum Inverter Efficiency 97.8 1 97.7 98.3 1 98.3 98.3 %
208V, 240V 97 @ 208V/97.59 240V/
r' ✓- - r-r CEC Weighted Efficiency 97.5 %
,gym g Y 24oV /98 @ 277V 98 @ 277V
r
97 5@
r r x ✓ r "� Nighttime Power Consumption <2.5 W
r r.� Supported Communication Interfaces RS485,RS232,Ethernet,Zlgbee(optional)
r ® a
- Safety UL1741,IEG-62103(EN50178),IEC-62109
Grid Connection Standards Utility-Interactive,VDE 0126-1-1,AS-4777,RD-1663,DK 5940,IEEE1547
Emissions FCC part15 class B,IEC61000-6-2,IEC61000&3,IEC61000.3-11,IEC61000-3-12
RoHS Yes
The only inverters specially designed for distributed DC architecture AC Output + r 3/4'Conduit
DC Input 3/4^conduit
ra Superior efficiency(97.5%)
Dimensions(HxWxD) 21 x 12.5 x 7/ 21 x 12,5 x 7.5/540 x 315 x 191 in/mm
all Small,lightweight and easy to install on provided bracket 540 x 315 x 172
�Z m5 a' Dimensions with AC/DC Switch(HxWxD) 30.5 x 12.5 x 7/ 30.5 x 12.5 x 7.5/775 x 315 x 191 (n/mm
Fj Built-in module-level monitoring Nartx�tY C 775 x 315 x 172
Weight 42/19 45/20.5 Ib/kg
in Communication t0 Internet via Ethernet Or Wireless +
Weight with AC/DC Switch 48.5/22 52/23.5 Ib/kg
rA Outdoor and indoor installation law cooling Natural Convection
s, Min.-Max.Operating Temperature Range -4/-20(CAN version-40/-40)to+140/+60 'F/'C
to Integral AC/DC Switch ( j Protection Rating NEMA 3R
r 'FLgrer InPOI DC power may ba Installed;analyte)early AC performance.
•s The foAowipg Part Numbers ere milahe(CAN Pita are ePg.We for the Ontario m and mlaoen:
208/240V,min.ope,aLngtempAF/"20C:SM000AUS,SE3600AUS,SE6OWArtl,SE6°OO"S,SE7000"S
277V,min.merang tempAF/-20C:SE6000ALS,5E6000XUS,SE7000AU S
208/240M,min.operating tempAOF/dOC:SE300GA-USC.AN,SE3800"SPAN,SE5 A,USCM,SE60odWSCAN
27 TV,min operating temp AGF/A X:SE5000AU SCAN,SE6000AUSCAN,SE70°OAUSCAN
ra USA R Germany ri Italy ea France t-A Japan El China id Israel
solar••o
of energy- wwl"rdg,mhrdocom a°dg,l°fb°rs,energy-
architects ..
®SolarEdge Tea mouyjes,Inc.20042012.All rghts reserved.div,o m,,the SolarEdge logo,3.SmjE to OF ENERGY ant OPNMQEO BY SOIAfiEOGE are tidemarlts or registered trademarks of SolarEdge Ted,nobgles,Inc.All
other tidemarks mentioned herein are trademarks of their respective owrars.Date:06/2012.V03.SobJcW!o change without notke.
I
I
I
i
.r-
.;.
1-... ,E,'.ter., ,.,, r r .,�.xr �. ,�.,.. ,__rr,-x, ..: . -. :�.,, r ,r' a✓` _.., .,��. , ;":.l sr''� �' „ ,-.; r. ,.,.,, a x (,.:.<,
-G. :: .� -,: .,.. f,.., ;:�:.,v„a'.,„ z'r,� "a`;.,.°-',.. r'r;1,�. ,.,,�. ,a. .�,� : 1 ,. 3 .<, t_. & .:.M_y k-s ...�.�,..�.. �.,' '' �fi'...� ,!v .r.,.r ..a%=�,..,F.,,�'�`r,°✓r;,�
.-
- � Nom. �� .✓:; ,.� � -i 7
... i r�.t` '�'c 91"`fir :-4..✓' ."..✓ ..ri'�', ..:., ;. .��f�F',� ,.:. w.. `t- � �.. ..., .X � .-, _, ": .-, r. :£ � ,r
solar. ..,
,
r.r_
..s.
.✓.�` .ssr, -_.. ..rr-. ".:. �!".,.�`..'.�..r...,.....„.�. 3.i''j' ,&., _ 1 -=;..,,:�- f`� ,M'_sf..� ,:r..
'
r. �:x. � `?. fir: r' f ✓��
HIGHLIGHTS
Module level MPPT-optimizes each module Independently ii Lower installation costs with faster design, less wiring, DC
-j Dynamically tracks the global maximum operating point for both disconnects and fuses
" m Easy and flexible installation—use the same installation methods
modules and PV inverter Y
IT Module-level monitoring for automatic module and string level as exist today
fault detection allowing easy maintenance i-i Allows parallel uneven length strings and multi-faceted
rf Electric arc detection-reduces fire hazards Installations
® ® ® ® ® a rt Unprecedented installerand firefighter safety mode-safe module ri Allows connection of different module types simplifying inventory
:f voltage when inverter is disconnected or off considerations
— - w Connection of one or more modules to each power optimizer Immediate installation feedback for quick commissioning
w„ TECHNICAL DATA
OP250-LV OP300-MV/OP400-MV OP400-EV(Q4 2011)
r tk Rated Input DC power 250 300/400 400 W
r # Absolute Maximum Input Voltage(Voc) 55 75 125 Vdc
' r
MPPT Operating Range 5-55 5-75 60-125 Vdc
., '
Maximum Input Current 10 10 5.5 Adc
Reverse-Polarity Protection Yes
Maximum Efficiency 99.5 %
t European Weighted Efficiency 98.8 %
,.
� ,� `�� ,•„v CEC Weighted Efficiency 98.7 %
�. Inductive Lightning Protection 1 m/ft
� r z Overvoltage Category II
x
Maximum Output Current 15 Adc
Operating Output Voltage 5-60 Vdc
Total Maximum String Voltage(Controlled by 500 Vdc
Inverter)-US and EU 1-ph
Total Maximum String Voltage(Controlled by 950 Vdc
Inverter)-EU 3-ph
mmmss= �• r •� �•
Safety Output Voltage per Power Optimizer 1 Vdc
Minimum Number of Power Optimizers per 8(1-ph system)/16(3-ph system)
String(1 or More Modules per power optimizer)
A Superior approach t0 maximizing the throughput Of photovoltaic Maximum Number of Power Optimizers per Module power dependent;typically 20-25(1-ph system) /
String(1 or More Modules per power optimizer) 45-50(3-ph system)
systems using module embedded electronics Parallel Strings of Different Lengths or Yes
Orientations
r
Up to 25%increase in power output
EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3
Di Superior efficiency(99.5%)-peak performance in both mismatched and unshaded conditions Safety IEC-62103(class II safety),UL1741
® Flexible system design for maximum space utilization Material UL-94(5-VA),UV Resistant
RoHS Yes
* Next generation maintenance with module level monitoring and smart alerts r
® Unprecedented installer and firefighter safety :'`, 1 Dimensions(WxLxH) 120x13Ox37/4.72x5.11x1.45 mm/in
Weight 450/1.0 gr/Ib
E WxanH ;y output PV Wire 0.95 in/3 ft length;6 mm2;MC4
y'*v• Input Connector MC4/Tyco/H+S/Amphenol—H4 4 '
Operating Temperature Range -40-+65/40-+150 •C/OF
III The most cost effective solution for residential,commercial and Protection Rating IP65/NEMA 4
large field installations Relative Humidity 0-100
USA 900 Golden Gate Terrace,Suite E,Grass Valley CA 95945,USAe Rt C solar=
Germany Bretonischer Ring 18,85630 Grasbrunn(Munich),Germany C��Jy
Japan B-9 Ariake Frontier Building,3-7-26 Ariake,Koto-Ku,Tokyo 135-0063,Japan architects of energy^
Israel 6 HeHarash St.PO.Box 7349,Neve Neeman,Hod Hasharon 45240,Israel www.solaredgo.com ! �.,,-;"'
®SolarEdge Technologies,Inc.20092011.All rights reserved.SOLAREDGE,the SolarEdge logo,ARCHITECTS OF ENERGY and OPTIMIZED BY SOIAREDGE are trademarks or registered trademarks of
architectsof energy- SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:09/2011.Subject to change without notice.
i
i
I
® GreenTriplex PM250MO I t250-27Owp>
Green"Trex
Electrical Data Dilnen ons mm(inchl
Trp,k'mA,AP r,rt P•i ]SOW 755w 20W 265: NOWPM250MO I tl�iui 1" psq ?
Typtiod,eFf"keq 150; 15,8; 161% 164% 168%
TYy h mloalVW.?'V,(V) 307 30.6 317,9 31A 31,1 ���
Mono-Crystalline Typ NominalCtncnti�(A) 822 634 046 058 0.70 _I I I
Typ Open Gm t5o'tzgeVo•:(V) 37.8 37.9 300 39.1 30.2 Yr }
PhotoPhotovoltaic Module Ty %e iCrt aCuncot I,(A) 8.46 8.72 8,78 0 90.04 8: I I I II II I�
voltaic Mar mum Werance of F 01 Oy 1e:9
t63sn i
•SIC ', loll YSfi(.� Hlf ,) 7 � -
Power Ran e
/ 250-270Wp
Temperature Coefficient
NOCT 4622'C
Highly Strengthened Desi 936'
V B Y 8emeDesign lypTerpwIwe rt,:I.ntufNs 044%1P )
3655 'I
^� '� ,<,• P T Module cornplles vriUa ndranced loading tests[o T','u a�ua Coelt•ie,t of I 0.06 i l K
f•-�klx.[ 1
to r Co ki-t ofV,. 0.30-4/K ��__ `1, _
• meet 54001'a loading r-c-qulmment5
wa
f•<Y;O'T r. nao,.i. C rl Fa`-s r;u..,, �.__-H_O J. ., fIS�[�.r=. x,7 "I"+alIM[ Ho'csx4 ; {
I to
3 Bulbar Design 9 I• I4 0 573
-" r
+ ` (035) 1 (ass)
rs« Enhance current transmission and module Mechanical Characteristics
-- crow i 1
32
rellablli
h n m nsasos(L x W x H) 1639 x 983 x 40 ty (b4 53 x 38.70 x 1.57 In) HAA x 4 (39.3 Y) 993' (126)
wcgit 185kg(O"I1 i) hold) 6 pafYa) AACrs:r<coon
Front Glass Hlgh w—p t[arr:Var glass 0 t ye—J),3.2 mrn(0.13 in) I
60 mwagy Oma sofar(O's,156 x IS6 ince(6 x 61n) d
Optional
i
��•a,'"�' Cd,€ucapsuladon EVA
,." ,.,r AC photovoltaic fluk S11-t Compavte P'rn,Mack t
= 1r JJ _
i I l)8
ra d Integrated with a Micro inverter,the module Iran n A I E 11t9p
11 name An�odixed ah minum fame M�I Owl-
5--• high and stable AC power output via panel level � •o- f f•tar,:ting Hob
Jun�don
8— IP-65 rat'l v,itl,3 bypass
MPPT G cun4xiG Hoes
CabEr I X4 n+m'(0,04 L0 m(39.37 In)
CorsxctorTM MCAcompaabBe I-V Curve
IN dA
IQ 1 00O W/m[
PV CYCLE Operating Condidons ;o
'✓;,-fn
OW whn'
r� Op,^+anngTrmperatnre -40-+85`C
A t&,nt Tempests Ra,W -40-•+45`C 0
i
Max.SystcmVe?rage EC/UL IOOOV 1600V
S(W Fuse Rat ng ISA
I9 :;romt Swfw teed Cargdty Tested up to 54W Pa word+ng to IEC 61215(advan(ed Ill)
O
d 5 to IS 19 25 30 15 ,0
tkdrsgc(V)
Warranties and Certifications
---- — --- -- - - _---------------
ProdcxtWarranty IO years for matcdal and workmanship
Perioesnance Go--e¢ Guana,teed output o19ty%for 10 years and 2-09 W;25 y,:•.:ra .
Cert"umns According o>IEC 6121 S,IK b17J0 and Ui.1703 y�.�idyines"
Packing configuration
Canner 20'GP 40'GP 40'HQ
Pecespe pallet 23 23 23
PaHeu per Camaincr 6 13 26
r P,eces per m�waiser 130 299 598
V,.zaimi NW-A Clstk Back Sheet mlite 8,16.Sheet
8hckFnmc Silver Frarne
''I © AU OpItonics Corporation
W�
� No,I,LI-Hsin Rd.2,Hsinchu Science Park,Hsinchu 30078,Tahvan J4 ,-
BenQ
® ' Tei;x886.3.500-8899 e•rnali:BcnQSolar(?auo.com vvwvr.BenQSolaecom ® g�rl(l i
Solar � - __-- - --------_---- ----- - � I '��// ,
BenQ Solar Is a division of AU Optronics rt r r r s sqt.n n.,-.., Solar
Jim
i
j
I
I