Loading...
Combined Set_24.pdfPROJECT DATA LOT AREA: 9716 SQ.FT EXISTING PROJECT DATA : (E) 1F HOUSE AREA: 1006 SQ.FT. (E) GARAGE: 547 SQ.FT. (E) ENTRY PORCH: 37 SQ.FT. 1432 SQ.FT. (E) 2F HOUSE AREA: 590 1432 SQ.FT. (E) 2F DECK: 258 SQ.FT. (E) EAVES & ROOF 330 SQ.FT. bus Ave OVERHANG: HISTORICAL BUILDING CODE No•aet (E) FAR: (1006+547+1432)/9716=2985/9716 =30%<45% (ALLOWABLE) (E) LOT COVERAGE: (1006+547+37+258+138+330)/9716 2316/9716 23.86% NOTE: ONLY 138 SQ.FT. OF 2ND FLOOR CONSIDERED FOR LOT COVERAGE CALCULATION AS REST OF THE 2ND FLOOR HOUSE AREA FALLS ABOVE 1ST FLOOR HOUSE FOOTPRINT. REFER SITE PLAN ON SHEET A-2. PROPOSED NEW ADDITION: (N) 1F HOUSE AREA: 768 SQ.FT. (N) 1F UNCOVERED PATIO: 285 SQ.FT. (N) 2F DECK: 332 SQ.FT. (N) EAVES & ROOF 91 SQ.FT. OVERHANG: PROPOSED PROJECT DATA: (N) 1F HOUSE AREA: 1774 SQ.FT (N) 1F UNCOVERED PATIO: 285 SQ.FT. (E) GARAGE: 547 SQ.FT. (E) ENTRY PORCH: 37 SQ.FT. (E) 2F HOUSE AREA: CALIFORNIA 1432 SQ.FT. (N) 2F DECK: 590 SQ.FT. (N) EAVES & ROOF 421 SQ.FT. PLUMBING CODE OVERHANG: CALIFORNIA ENERGY CODE (N) FAR: (1774+547+1432)/9716=3753/9716 =39%<45% (ALLOWABLE) (N) LOT COVERAGE: (1774+547+37+61+69+421)/9716 - 2909/9716 - 30% NOTE: -ONLY 69 SQ.FT. OF 2ND FLOOR CONSIDERED FOR LOT COVERAGE CALCULATION AS REST OF THE 2ND FLOOR HOUSE AREA FALLS ABOVE 1ST FLOOR HOUSE FOOTPRINT. - ONLY 61 SQ.FT. OF 2F DECK AREA CONSIDERED FOR LOT COVERAGE CALCULATION AS REST OF THE 2ND FLOOR HOUSE AREA FALLS ABOVE IST FLOOR HOUSE FOOTPRINT. REFER SITE PLAN ON SHEET A-2. 2ND FLOOR TO 1ST FLOOR RATIO 1432/(1774+547)/-62% 6*9 KIM' MCI] dl INBL[.`1:=11KIM K 71►1[it 0E&IOlWaIW 1. IN THE EVENT THAT ANY UNUSUAL CONDITION NOT COVERED BY THE SPECIAL PROVISIONS IS ENCOUNTERED DURING THE GRADING OPERATIONS, THE SOIL ENGINEER SHALL BE IMMEDIATELY NOTIFIED FOR FURTHER RECOMMENDATION. FIRE SPRINKLER SYSTEM WILL BE PROVIDED AND INSTALLED PER NEPA 13R 2016 EDITION STANDARD". THE OWNER(S), OCCUPANT(S) AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER SERVICE IS REQUIRED. A STATE OF CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO BEGINNING THEIR WORK. CRC SEC. 313.2 AS ADOPTED AND AMENDED BY CUPMC. SPECIAL CONDITIONS LIST: (1) GEOLOGIC HAZARD; SOIL LIQUEFACTION - INUNDATION SITE. ADDITION OF 1ST FLOOR KITCHEN/ FAMILY ROOM AND SECOND FLOOR DECK 1077 MILKY WAY, CUPERTINO, CA 95014 APNmm 362-18-042 PROJECT INFORMATION PROJECT DESCRIPTION: IMMEWATAIN NEW HOUSE ADDITION OF 768 SQ.FT ON FIRST FLOOR TO INCLUDE (N)KITCHEN & (N) FAMILY ROOM & (N)1/2 BATHROOM. NEW UNCOVERED PATIO OF 285 SQ.FT. ON 1ST FLOOR IN REAR YARD. 2ND FLOOR NEW DECK ADDITION OF 332 SQ.FT. REMODEL (E) DECK. REMOVE (E) KITCHEN. NEW FURNACE TO SERVE IST FLOOR AREAS. PROPOSED LOCATION AS SHOWN ON SHEET A-3 APN: 362-18-042 CONSTRUCTION TYPE: VB OCCUPANCY GROUP: R3/U ZONING: R16 STORIES: 2 - RESIDENTIAL LOW DENSITY (1-5 DU/AC) IS G 0 E VICINITY MAP CALIFORN A ADMINIST _ATI OD __j CALIFORNIA BUILDING CODE, VOLUMES 1 & 2 2016 CALIFORNIA a 2016 CALIFORNIA Creekline 2016 CALIFORNIA MECHANICAL CODE 2016 lot,peg PLUMBING CODE 2016 CALIFORNIA ENERGY CODE bus Ave CALIFORNIA HISTORICAL BUILDING CODE No•aet CALIFORNIA EIRE CODE (CFC) 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 CALIFORNIA Chi 2016 EDITION APPROX. CALIFORNIA CODE OF REGULATIONS (CCR) THE s� TITLE 24 (CALIFORNIA BUILDING STANDARDS CODE) y' V ai Pv e GAUGE REFR.. BLDG. 789E GALV. GALVINIZED REINF. REQ'D. Orion Ln BLOCK G.C. .T BLK'G. BLOCKING G. L. GLASS RM BM. k GR. GRADE N of BOTTOM GYP. GYPSUM a BTWN. BETWEEN GYP.BD. toy S. C. B.U.R. BUILTUP ROOFING t3, s o SCHED. B. W. BOTHWAYS Lu HOSEBIBB S V) w IT. C. HOLLOWCORE DRAWING INDEX SHEET SHEET TITLE SHEET SHEET TITLE N0: CEILING HDWD. N0: SIM. A-1 CAULKING COVER SHEET AND PROJECT INFORMATION STRUCTURAL: A-2 CLR. 1F SITE/ROOF PLAN S-1 STRUCTURAL COVER SHEET 1 A-3 C.M.U. 2F SITE/ROOF PLAN S-2 PIER AND FOUNDATION DETAILS A-4 COL. IF FLOOR AREA DIAGRAM S-3 STRUCTURAL FLOOR PLANS A-5 2F FLOOR AREA DIAGRAM S-4 DECK DETAILS A-6 CONC. EXISTING 1F PLAN ENERGY: A-7 SIGN DATE: 07-10-2018 PROPOSED 1F PLAN T-1 TITLE 24 SHEET 1 A-8 STIFF EXISTING & PROPOSED 2ND FLOOR PLAN T-2 TITLE 24 SHEET 2 A-9 STL. ELEVATION -1 CONTINUOUS INSUL. A-10 STRUC. ELEVATION -2 CERAMICTILE INT. A-11 SUSP. ELEVATION -3 A-12 TR CROSS SECTIONS DEGREE JAN. A-13 T&B FLOOR PLAN NOTES/ DETAILS DETAIL JNT. A-14 TER. CALGREEN CHECKLIST DRINKING FOUNTAIN JST. E-1 T&G ELECTRICAL PLAN /NOTES THK. DAG. DIAGONAL KITCHEN T/ DIA. %C DIAMETER KIT. TYP. DN. DOWN DS. DOWNSPOUT LAB. LABORATORY DWG. DRAWING LAM. LAMINATE U.O.N. LAV. PROJECT INFORMATION PROJECT DESCRIPTION: IMMEWATAIN NEW HOUSE ADDITION OF 768 SQ.FT ON FIRST FLOOR TO INCLUDE (N)KITCHEN & (N) FAMILY ROOM & (N)1/2 BATHROOM. NEW UNCOVERED PATIO OF 285 SQ.FT. ON 1ST FLOOR IN REAR YARD. 2ND FLOOR NEW DECK ADDITION OF 332 SQ.FT. REMODEL (E) DECK. REMOVE (E) KITCHEN. NEW FURNACE TO SERVE IST FLOOR AREAS. PROPOSED LOCATION AS SHOWN ON SHEET A-3 APN: 362-18-042 CONSTRUCTION TYPE: VB OCCUPANCY GROUP: R3/U ZONING: R16 STORIES: 2 - RESIDENTIAL LOW DENSITY (1-5 DU/AC) IS G 0 E T SP IN E SY TE B ILD G OD S: 2016 CALIFORN A ADMINIST _ATI OD 2016 CALIFORNIA BUILDING CODE, VOLUMES 1 & 2 2016 CALIFORNIA RESIDENTIAL CODE (CRC) 2016 CALIFORNIA ELECTRICAL CODE (CEC) 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA HISTORICAL BUILDING CODE 2016 CALIFORNIA EIRE CODE (CFC) 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE 2016 CALIFORNIA REFERENCED STANDARDS CODE 2016 EDITION APPROX. CALIFORNIA CODE OF REGULATIONS (CCR) THE CITY OF CUPERTINO MUNICIPAL CODE (CUPMC) TITLE 24 (CALIFORNIA BUILDING STANDARDS CODE) ALL APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL CODES, LAWS & REGULATIONS. GAUGE ENGINEER: DESIGN EVEREST CONSULTING ENGINEERS 365 FLOWER LANE MOUNTAIN VIEW, CA 94043 PHONE: 888 311 3015 PHONF: AAKASH@DESIGNEVEREST. COM GEOTECH: AMERICAN SOIL TESTING INC. MARCH 30, 2018. 2734 S. BASCOM AVENUE, SAN JOSE, CA 95124 408559-6400 WWW.AMERICANSOILTESTINGINC.COM FILE NO. 18-5123-S GENERAL NOTES ALL CONSTRUCTION SHALL COMPLY WITH ADOPTED ORDINANCES AND POLICIES OF THE GOVERNING AGENCY AND THE LATEST ADOPTED ADDITIONS OF THE FOLLOWING: 2016 CALIFORNIA BUILDING & RESIDENTIAL CODE (CBC,CRC), 2016 CALIFORNIA PLUMBING CODE (CPC), 2016 CALIFORNIA MECHANICAL CODE (CMC), CALIFORNIA FIRE CODE (CFC), CALIFORNIA ELECTRICAL CODE 2016, CALIFORNIA ENERGY CODE 2016, AND 2016 CALIFORNIA GREEN BUILDING CODE. THE CONTRACTOR SHALL ERECT AND MAINTAIN, AS REQUIRED BY EXISTING CONDITIONS AND PROGRESS OF THE WORK, ALL REASONABLE SAFEGUARDS FOR SAFETY AND PROTECTION INCLUDING POSTING DANGER SIGNS AND OTHER WARNINGS AGAINST HAZARDS, PROMULGATING SAFETY REGULATIONS AND NOTIFYING OWNERS AND USERS OF ADJACENT UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS, GRADES AND OTHER CONDITIONS, AND HE SHALL CORRELATE ALL SUCH ITEMS AT THE JOB SITE. HE SHALL REPORT ANY DISCREPANCIES TO THE DESIGNER FOR CLARIFICATION AND/OR CORRECTION PRIOR TO BEGINNING ANY WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE WORK AND COORDINATION OF ALL TRADES WITH THE GOVERNING AGENCIES, AND SHALL PROVIDE ALL MATERIALS AND LABOR SHOWN IN THESE PLANS TO RENDER THE JOB COMPLETE. CHANGES TO THE PLAN DURING CONSTRUCTION OTHER THAN: CABINET CHANGES WHEN NOT BEING SUPPORTED ENTIRELY BY THE ROOF STRUCTURE, INTERIOR DOOR AND ZERO -CLEARANCE FIREPLACE RELOCATION SHOWN ON THE APPROVE PLANS, A SINGLE NONBEARING WALL RELOCATION WHEN NOT CREATING AN ADDITIONAL ROOM, AND INTERIOR NON-STRUCTURAL WALL FINISHES; SHALL CAUSE PLANS APPROVAL AND CONSTRUCTION TO BE SUSPENDED, A NEW PLAN CHECK (FOR THE NEW PLAN CHANGES) WILL BE SUBMITTED FOR REVIEW AND APPROVAL THROUGH THE COMMON PLAN CHECK PROCESS. CALGREEN NOTES: PER CALIFORNIA CIVIL CODE ARTICLE 1101.4 AND CALGREEN SECTION 301.1, FOR ALL BUILDING ALTERATIONS OR IMPROVEMENTS TO A SINGLE FAMILY RESIDENTIAL PROPERTY, EXISTING PLUMBING FIXTURES IN THE ENTIRE HOUSE THAT DO NOT MEET COMPLIANT FLOW RATES WILL NEED TO BE UPGRADED. WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 gpf WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 gpf. SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 gpm WILL NEED TO BE REPLACED WITH A MAXIMUM 2.0 gpm SHOWER HEAD. LAVATORY AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 gpm WILL NEED TO BE REPLACED WITH A FAUCET WITH A MAXIMUM FLOW RATE OF 1.5 gpm (OR 1.8 gpm FOR KITCHEN FAUCETS). ABBREVIATIONS NOTE:CLARIFY WITH DESIGNER ALL ABBREVIATIONS NOT LISTED. ONCENTER PLYWOOD O.D. OUTSIDEDIAMETER PAIR PLAS. AB. ANCHOR BOLT FLUOR. FLUORESCENT QUARRYTILE ACT ACOUSTICAL CEILINGTILE FND. FOUNDATION PLYWD. A.F.F. ABOVE FINISHED FLOOR F.O.B. FACEOFBRICK PR. AGGR. AGGREGATE F.O.C. FACEOFCONCRETE AL. ALUMINUM F. S. FULLSIZE Q.T. ALT. ALTERNATE FT. FOOTORFEET R APPROX. APPROXIMATE FTG. FOOTING R.D. ARCH. ARCHITECTURAL FURR. FURRING RE: BD BOARD GA. GAUGE REFR.. BLDG. BUILDING GALV. GALVINIZED REINF. REQ'D. BILK BLOCK G.C. GENERALCONTRACTOR BLK'G. BLOCKING G. L. GLASS RM BM. BEAM GR. GRADE R.O. BOT. BOTTOM GYP. GYPSUM S BTWN. BETWEEN GYP.BD. GYPSUMBOARD S. C. B.U.R. BUILTUP ROOFING o SCHED. B. W. BOTHWAYS H.B. HOSEBIBB SECT. V) w IT. C. HOLLOWCORE S. F. C. J. CONTROLJT. H/C HANDICAPPED SHT. CLG. CEILING HDWD. HARDWOOD SIM. CLKG. CAULKING HDWE. HARDWARE SPEC. CLR. CLEAR H.M. HOLLOWMETAL SQ.OR C.M.U. CONCRETE MASONRY UNIT HR. HOUR S.S. COL. COLUMN HT. HEIGHT STAGG. HVAC HEATING,VENTILATIONAND STD. CONC. CONCRETE PROJECT INFORMATION SIGN DATE: 07-10-2018 CONN. CONNECTION SCALE: AIRCONDITIONING STIFF CONSTR. CONSTRUCTION 1. D. INSIDEDIAMETER STL. CONT. CONTINUOUS INSUL. INSULATION STRUC. C.T. CERAMICTILE INT. INTERIOR SUSP. TR DEG. DEGREE JAN. JANITOR T&B DET./DTL. DETAIL JNT. JOINT TER. D. F. DRINKING FOUNTAIN JST. JOIST T&G THK. DAG. DIAGONAL KITCHEN T/ DIA. %C DIAMETER KIT. TYP. DN. DOWN DS. DOWNSPOUT LAB. LABORATORY DWG. DRAWING LAM. LAMINATE U.O.N. LAV. LAVATORY E EAST LT. LIGHT VCT (E) EXISTING VER EA. EACH MAX. MAXIMUM VERT. E. J. EXPANSIONJOINT MECH. MECHANICAL E. 1. F. S. EXTERIOR INSULATION AND MEMB. MEMBRANE W FINISHSYSTEM MFR. MANUFACTURER W/ EL.ELEV. ELEVATION M.H. MANHOLE W. C. ELEC. ELECTRICAL MIN. MINIMUM WD. ELEV. ELEVATION MISC. MISCELLANEOUS W/0 EVER EMERGENCY M.O. MASONRYOPENING ENCL. ENCLOSURE MTL. METAL EQ. EQUAL MUL. MULLION R EQUIP. EQUIPMENT N NORTH F.D.C. F. W. EACHWAY N.I.C. NOTINCONTRACT F.E.C. E.W.C. ELECTRIC WATER COOLER NO. NUMBER EXP. EXPANSION NOM. NOMINAL EXT. EXTERIOR F.A. FIREALARM N.T.S. NOTTOSCALE A SECTION: A3 SECTIONLETTER SHEETNUMBER tA3 DETAIL: DETAILNUMBER SHEETNUMBER ODOORNUMBER OWINDOWTYPE PLASTER O.C. ONCENTER PLYWOOD O.D. OUTSIDEDIAMETER PAIR OH. OVERHEAD 00 OPG. OPENING QUARRYTILE OPP. OPPOSITE RISER PCT. ROOFDRAIN P. L. REFERTO... P.LAM REFRIGERATOR F.E. REINFORCED REQUIRED ROOM ROUGHOPENING SOUTH F. F. SOLIDCORE SCHEDULE IN. SECTION F. L. SQUAREFOOT FLR. SHEET F. D. SIMILAR SPECIFICATION FDN. SQUARE STAINLESSSTEEL STAGGERED STANDARD STIFFENER STEEL STRUCTURAL SUSPENDED TREAD TOPAND BOTTOM TERRAZZO TONGUE&GROOVE THICK TOPOF TYPICAL UNLESSOTHERWISENOTED VINYLCOMPOSTIONTILE VERIFY VERTICAL WEST WITH WATERCLOSET WOOD WITHOUT PRE -CAST PROPERTYLINE PLASTIC LAM I NATE FIRE EXTINGUISHER FINSHFLOOR FINISH FLOWLINE FLOOR FLOORDRAIN FOUNDATION CENTERLINE PLATE FIRE DEPARTMENT CONNECTION FIRE EXTINGUISHER CABINET F.H.C. FIRE HOSE CABINET ARCHITECTURAL SYMBOLS 44 SHEETLAYOUTDESIGNATION Al VIEWNUMBER SHEETNUMBER COLUMNGRID CENTERLINE i IfI CASEWORK 12 4 ROOFSLOPEINDICATION 3 EXTERIORELEVATION: A5 ELEVATIONLETTER SHEETNUMBER INTERIORELEVATION: ELEVATIONLETTER SHEETNUMBER ROOMNUMBER ELEVATIONTAG 1 R ISION PROPERTYHNE I N W E NORTH DESIGNATION S 1 "DN. CHANGEINELEVATION Lu 00 O 00 Lu m rn m � O O Lu W Lu v7 w M z Z guQ z LL '� >o W COD O z mc:) � Z �0zm m J cl) � 00 O 00 S D Ln W Lu z o O = Q U O z W w C] Q U O Q Ln � �Q Lu � U J 0 F- z F - z Lu w z O � O � O a O O U w V)cW o z a z a V) w = w Lu H 00 � N 00 r -I r -I QN m M Lr O O IL=u COVER SHEET & PROJECT INFORMATION SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-1 LEGEND WALLS NOTE: NO NEW LANDSCAPE PROPOSED I� / I `v I 10'CUPERTINO SANITARY I� DIST. EASEMENT �� I Q° I� �- P � A\O O° P ALL THE TREES ARE EXISTING '- 4' OAK TREE & NOT INSIDE THE PROPER To AIN (E) OAK TO REMAIN (E) OAK TO REMAIN (E) 25' OLIVE TREES TO REMAIN (E) OAK TO REMAIN d d ALL THE TREES ARE EXISTING & NOT INSIDE THE PROPERTY (E) 55' PINE TREES TO REMAIN 10'CUPERTINO SANITARY DIST. EASEMENT 5' CITY OF SAN JOSE SANITARY SEWER EASEMENT EXISTING 1ST FLOOR SITE/ROO (E) HOUSE FOOTPRINT IW I a_ l0 I ICL I I °° I I I I I 2ND FLOOR I DECK LINE 2`ID FIL 4 izINEI d 138 SQ.FT. OF 2ND FLOOR HOUSE AREA TO BE CONSIDERED IN LOT COVERAGE 6' CALCULATIONS 0 I I I (E) 7'-0" HIGH WOOD FENCE- NO CHANGE I I "WATER WH -RCHANGE I H — EXISTING SANITARY CLEANOUT (NO CHANGE) I U2 F ND FLOOR LINE 0 . . . . . . (E) GAS METER -NO CHANGE — — °— v ° a v I 4 d d (E) DRIVEWAY d 4 d NO CHANGE 4 v v d v d d I 4 v d v 4 d d v 4 v I v v d d d 4 c v d4 d v v d l'M v 4 d v d d I v v 4 4 d � d d v d d I v v 4 v I a 4 d v v Q d d 4 n v I u / v a d �- d d v 4 4 v v I� d d r ^ v d d rt) v v v — AM 4a Q d 33.1 EE 0 - FING PLAN RESIDENTIAL LANDINGS & THRESHOLDS SECTIONS R311.3 & R311.7.6 8311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NO BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCESS 1 /4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT R311.3.1 FLOOR ELEVATIONS AT REQUIRED EGRESS DOORS. LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOORS SHALL NOT BE MORE THAN 1 1 /2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7 3/4" INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED TH DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. ALL THE TREES ARE EXISTING & NOT INSIDE THE PROPERTY.- (E) ROPERTY (E) OAK TO REMAIN (E) 25' OLIVE TREES TO REMAIN (E) OAK TO REMAIN (E) OAK TO REMAIN (N) LANDING LANDING NJ ALL THE TREES ARE EXISTING & NOT INSIDE THE PROPERTY (E) 55' PINE TREES TO REMAIN 4 d 10'CUPERTINO SANITARY DIST. EASEMENTPV PX X\40/0 / Q° / \O / 0/0 (E) 20'-24' OAK TREE/ TO REMAIN O/ 10'CUPERTINO SANITARY DIST. EASEMENT SANITARY NOTES. • Construction debris, paint, and waste from the construction shall not be discharged to sanitary sewer • Storm water surface or roof drains, other general surface water runoff, or condensation from any residential HVAC equipment shall not be discharged to the sanitary sewer 24"x36" SCALE: 1" - 10'-0" 1 5' 1° 21,1 2 1 PROPOSED 1ST FLOOR SITE/ROOFING PLAN 49'-10" w zP U Q M 23' -9 w 0 6 E Un 2ND FLOOR o 20-8 DECK LINE � ,, A 2NDaFLO w LINE , n d a a a 6' SHOWER ) WATER — W" CHANGE > — El ( N I F ND FLOOR LINE— 0 \ d d a 4 Ln d d 17-- v d v a o d d 4 <' v v LLJ r ^ d a z V4 4 W CL Off° °� d - z O 0 USABLE REAR YARD SPACE =2874 SQ.FT. (LOT WIDTH AT FRONT SETBACK X 20 =42FT. X 20=840 SQ.FT.) 2874>840 SQ.FT. (OK) PROPOSED LOCATION OF PREFAB SPIRAL STAIRCASE 61 SQ.FT. OF 2ND FLOOR DECK AREA TO BE CONSIDERED IN LOT COVERAGE CALCULATIONS 69 SQ.FT. OF 2ND FLOOR HOUSE AREA TO BE CONSIDERED IN LOT COVERAGE CALCULATIONS 24"x36" SCALE: I" = 10'-0" 0" 5' 10' 20' r44 0 z vi P:: cn cr_ LU w 0 U ::I- M Q a Ln U a < W J 0 z z LU LU z 2 2 0 0 0 F- a U U 0 0 U cn w w W (n Ln o z z Cl- In- v)V) LU LU 00 00 )..I..) H N r -i QQ N M M lf1 O O 1 ST FLOOR/ ROOF PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 Cn Uj 00 0 Y� 00 UjLn U0 LU m O11 -o LUz LU Ln w M z <U U - z 3: Lu Ln > 0 W � z m � '� Q zLn �' "D z m rnFZ Cn J 00 0 00 S w WLn z z O U � r44 0 z vi P:: cn cr_ LU w 0 U ::I- M Q a Ln U a < W J 0 z z LU LU z 2 2 0 0 0 F- a U U 0 0 U cn w w W (n Ln o z z Cl- In- v)V) LU LU 00 00 )..I..) H N r -i QQ N M M lf1 O O 1 ST FLOOR/ ROOF PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 LEGEND WALLS NOTE: NO NEW LANDSCAPE PROPOSED (E) 25' OLIVE TREES TO (E) 20'-24' OAK TREES TO REMAIN (E) FURNACE SERVING THE 2ND FLOOR AREA IS IN THE ATTIC -NO CHANGE ELECTRIC LINE -TO 1 BRAKE (TO BE REP W/ 200 -AM (E) 25' OLIVE TREES' (E) 20'-24' OAK TREES TO REMAIN NOTE: A PRIVACY WAIVER HAS BEEN OBTAINED FOR THIS SIDE. SIGNED FORM HAD BEEN SUBMITTED DURING PRELIMINARY DESIGN REVIEW. PROPOSED LOCATION OF (N)FURNACE TO SERVE 1 ST FLOOR AREAS (E) FLOOR LEVEL OF STORAGE AREA TO BE RAISED TO MATCH WITH THE (N) DECK FLOOR LEVEL. (E) FURNACE SERVING THE 2ND FLOOR AREA IS IN THE ATTIC -NO CHANGE Lu > w LLjLu w z cn _j Luz os V) Lu D Q W EXISTING 2ND FLOOR SITE/ROOFING PLAN N 0 L0 77- 0 3� 1 4 i i i Ln LL] Z w n CL 24"x36" SCALE: I" = 10'-0" 0" 5' 10' 2C' 11%17" SCALE: I" = 20'-0" NOTE N 0 PRIVACY WAIVERS HAVE BEEN SIGNED FOR PROPERTY OWNERS ON 1075 AND 1081 MILKY WAY. �Z D i GAS SUPPLY LINE 36" UNDERGROUND a ��w ' WATER SUPPLY UNDERGROUND w - SEWER LINE 2 1 PROPOSED 2ND FLOOR SITE/ROOFING PLAN/ DRAINAGE PLAN 24„X36” SSCALE: 1 CALE: 1" = 20'-0" 5' 10' Iml 20' I 1 00 00 W r --I r -I H (V r -I Q (V M M Ln O O W fz O 00 Lr, a, M � 0 o � Lu z Q U Q a: LL j Lr) > rl O c J Z M Ln Q Z M M O 00 w Z O a A Lu a U r�-I Qo �rn Y U GJ G 0 2ND FLOOR /ROOF PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-3 cn K�lz z z � w w 1 DS III O O O III III o 0 I I I u I W Lu Lu S V) N �-3"E E 55' PINE TREES TO REMAIN 31'-6" ()()N 55' PINE TREES TO REMAIN 31'-6" '-3" O O 71STFLOOR 1ST FLOOR LINE N V) \ Lu Lu LINE i EXISTING 2ND FLOOR SITE/ROOFING PLAN N 0 L0 77- 0 3� 1 4 i i i Ln LL] Z w n CL 24"x36" SCALE: I" = 10'-0" 0" 5' 10' 2C' 11%17" SCALE: I" = 20'-0" NOTE N 0 PRIVACY WAIVERS HAVE BEEN SIGNED FOR PROPERTY OWNERS ON 1075 AND 1081 MILKY WAY. �Z D i GAS SUPPLY LINE 36" UNDERGROUND a ��w ' WATER SUPPLY UNDERGROUND w - SEWER LINE 2 1 PROPOSED 2ND FLOOR SITE/ROOFING PLAN/ DRAINAGE PLAN 24„X36” SSCALE: 1 CALE: 1" = 20'-0" 5' 10' Iml 20' I 1 00 00 W r --I r -I H (V r -I Q (V M M Ln O O W fz O 00 Lr, a, M � 0 o � Lu z Q U Q a: LL j Lr) > rl O c J Z M Ln Q Z M M O 00 w Z O a A Lu a U r�-I Qo �rn Y U GJ G 0 2ND FLOOR /ROOF PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-3 �mm U) Lu 00 O 00Lurn m ar->Lu O O W w�t.D Lu Z LL Lu Z Z �w� >o Lu ozm 0 Z °cn zm O 00 �00 Lu z o Q O = U � 1 F- FLOOR AREA CALCULATIONS 1: 641 SQ. FT. 2: 58 SQ. FT. 3: 62 SQ. FT. -_ 4: 28 SQ. FT. 5: 984 SQ. FT. 6: 319 SQ.FT '- ' _ ' o 7: 131 SQ. FT � z 8: 92 SQ. FT. 0 U qt 9x 2: 2 SQ. FT. Q Q Ln �Q 10: 4.8 SQ. FT. n I " W J TOTAL: 2321 SQ. FT. r- 0 9 10 (j) V) zz cW CW Zc C O O O cl-F- U V E2 O O cn w w W cn N � Z Z O O CL a cn Ln W W 00 00 W r -I H N r-1 Q N M M 111 O O Luaaaaa 1 ST FLOOR AREA DIAGRAM SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 �O A=4 PROPOSED 1ST FLOOR D I AG RAM 11 "x36" SCALE: 1/4" l' -O" 2' 4' 8' 11"x17" SCALE: 1/2" = 1'-0" PROPOSED 2ND FLOOR DIAGRAM 2F- FLOOR AREA CALCULATIONS 1: 2: 3 887 SQ. FT. 5 SQ. FT. 29.7 SQ. FT. 4: 224.56 SQ. FT. 5: 103.32 SQ. FT. 6: 165 SQ. FT 7: 4.8 SQ. FT 8 x 2: 9: 10: 1 SQ. FT. 9 SQ. FT. 0.07 SQ. FT. 11: 3 SQ.FT. TOTAL: 1432 SQ. FT. 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/2" = 1'-0" i uj ujV) >w uiz w z wcnz os r4 W 0 Q W L40 V) F- 27- z Lu Lu z C) moo moo V w cii tW z z O O CL 0- V) N Lu w = cr- 00 00 Lu H N r -I Q N m cl M Lf1 O O Lu O 00 Ln rn m o oLu lD z Q U Q LL Lu Lu Ln o > 8 J z M LL � Ln � r -i z m m z O 00 00 O AX F - Lu V � V J 0 2ND FLOOR AREA DIAGRAM SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 A=5 P❑RTI❑N OF EXI TO ME BE REM❑ ALLOW ADDITI❑R SEE SHEET A-8 PORTION OF THIS OPENING EXISTING FIRST FLOOR PLAN LEGEND (E) WALLS TO REMAIN (E) WALLS TO BE REMOVED 24"x36" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/2" = 1'-0" �mm (n uj ujV) >w z uj w z C (D Luz os L4- LU C) Q W Ln t/) F- 27- z z cW cW z ccc CcC O G G O O d 0 0 V w cii tW z z O O CL 0- V) N LU w = cr- 00 00 w H N r -I QN m M Ln O O w cc O 00 Ln rn m � o o Ln Lu CY) lD z Q U Q LL. ui LU Ln >c o c', J z m LL Ln rn z m m � O 00 O -, A EXISTING EIRST FLOOR PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 A=6 1 RESIDENTIAL LANDINGS & THRESHOLDS SECTIONS R311.3 & R311.7.6 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NO BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCESS 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT) R311.3.1 FLOOR ELEVATIONS AT REQUIRED EGRESS DOORS. LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOORS SHALL NOT BE MORE THAN 1 1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7 3/4" INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. FLOOR PLAN NOTES: BATHROOMS & KITCHEN: 22" MIN SHOWER DOOR CLEARANCE TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS. CEMENT BOARD SUBSTRATE FOR SHOWER WALLS. LAVATORY FACETS TO HAVE A FLOW RATE OF 1.5 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1) WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS. (CALGREEN 4.303.1) CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD.ETC) FOR TILE APPLICATION SURROUNDING THE BATH TUB WALLS. KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1) SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO HEIGHT NOT LESS THAN 6 FEET ABOVE THE FLOOR PER CRC R307.2. MULTIPLE SHOWERHEADS: COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GPM @ 80PSI OR ONLY ONE SHOWER OUTLET IS TO BE IN OPERATION AT A TIME. (CALGREEN 4.303.1.3.2) FAUCETS (CALGREEN 4.303.1.4) RESIDENTIAL LAVATORY FAUCETS (CALGREEN 4.303.1.5) ALL HOSE BIBBS INSTALLED SHALL BE PROTECTED BY AN APPROVED NON -REMOVABLE TYPE BACK FLOW PREVENTION DEVICE. BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY ROOMS, ETC., SHALL BE PROVIDED WITH NATURAL VENTILATION BY MEANS OF OPENABLE EXTERIOR OPENINGS W/AN AREA OF NOT LESS THAN 1/20 OF THE FLOOR AREA W/MIN. OF 1-1/2 SQ.FT. OR 5 AIR CHANGES PER HOUR. WALL SURFACE BEHIND CERAMIC TILE OR OTHER FIN. WALL MATERIALS SUBJECT TO WATER SPLASH SHALL BE CONSTRUCTED OF MATERIALS NOT ADVERSELY AFFECTED BY WATER. (APPROVED WR GYP. BD. INSTALLED ACC. TO C.B.0 4712.) PRIOR TO BUILDING FINAL INSPECTION AN 'APPLIANCE CERTIFICATE', SIGNED BY THE INSTALLER OR GEN. CONTRACTOR, SHALL BE POSTED IN A CONSPICUOUS LOCATION. TUB/SHOWER AND WATER CLOSET REQUIREMENTS: THE MIXING VALVE IN A SHOWER (INCLUDING OVER A TUB) SHALL BE PRESSURE BALANCING SET AT A MAXIMUM 120 DEGREE F. THE WATER -FILLER VALVE IN BATHTUBS/WHIRLPOOLS SHALL HAVE A TEMPERATURE LIMITING DEVICE SET AT A MAXIMUM OF 120 DEGREE F. THE WATER HEATER THERMOSTAT CANNOT BE USED TO MEET THESE PROVISIONS. (CPC 408.3, 409.4) NEW OR RECONFIGURED SHOWER STALL SHALL BE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES, BE CAPABLE OF ENCOMPASSING A 30 INCH DIAMETER CIRCLE. ANY DOORS SHALL SWING OUT OF THE ENCLOSURE HAVE A CLEAR OPENING OF 22 INCHES MINIMUM. (CPC 408.5, 408.6) SHOWER STALLS AND BATHTUB WITH SHOWER HEADS INSTALLED, SHALL HAVE WALLS FINISHED WITH A NON-ABSORBENT SURFACE FOR A MINIMUM OF 6 FEET ABOVE FLOOR. (CBC 1210 AND CRC R307.2) THE WATER CLOSET SHALL HAVE A CLEARANCE OF 30 INCHES WIDE (15 INCHES ON CENTER) AND 24 INCHES IN FRONT) (CPC 402.5). WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE) COMES INTO CONTACT WITH THE WALL OR FLOOR THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) WHEN A SHOWER IS SERVED BY MORE THAN ONE SHOWERHEAD, THE COMBINED FLOW RATE OF ALL THE SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GPM AT 80 PSI, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLE ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. WINDOW REPLACEMENT REQUIREMENTS: FENESTRATION (WINDOWS) SHALL BE LOW E AND DUAL PANE; AND A MAXIMUM U FACTOR OF 0.32 AND A MAX. SHGC OF 0.35. (2013 TITLE 24 ENERGY STANDARDS) EMERGENCY EGRESS WINDOWS (BEDROOM ESCAPE WINDOW) SHALL HAVE A MINIMUM OF 5.0 SQUARE FEET OF CLEAR OPENING ON GRADE LEVEL FLOOR AND 57 SQUARE FEET ON SUBSEQUENT FLOORS; AND A MINIMUM CLEAR OPENING WIDTH OF 20 INCHES AND HEIGHT OF 24 INCHES. (CRC 310) GLAZING SHALL BE TEMPERED IF: (CRC R308) LOCATED IN THE WILD LAND URBAN INTERFACE AREA, LOCATED LESS THAN 60 INCHES MEASURED VERTICALLY, ABOVE WALKING SURFACE OF SHOWER/TUB/STEAM ROOF, ETC., LOCATED IN HAZARDOUS LOCATIONS AS INDICATED PER CRC R308.4. PROVIDE A FALL PREVENTION DEVICE IF THE OPENING IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE AND THE LOWEST PART OF CLEAR OPENING IS LESS THAN 24 INCHES ABOVE FINISHED FLOOR. (CRC R312.2) PROPOSED FIRST FLOOR PLAN 24"x36" SCALE: 1/4" = 1'-0" 0" 2' 4 8' 11"x17" SCALE: 1/2" = 1'-0" �mm (n uj ujV) >w z uj w z z LLJ os E4 cn Lu M Q W � V) F_ z Lu w z � � 0 0 0 0 0 U Ulw w Lu N N M z z 00 0- a V) w 00 00 Lu H N r -I Q N M 0 M Lr O O Lu cc O 00 rn m 0 0 Ln WCY)� z Q U Q LL �W� 0m O z LL ��r-i (.0z m M 0 0 �00 0 -, A EXISTING FIRST FLOOR PLAN SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 UWA �mm cl) LLI 00 00 LEGEND Ln uj m (E) WALLS TO REMAIN o 0 > Lu l Ln GURADRAIL DETAIL AS SHOWN ON SHEET A-6W Lu CE) WAUUS T❑ BE REM❑VED W Z Q U x — J Q (E) DECK NET HATCHEDfilNEW WAUUS V ,� u- HATCH SECTION OF BECK T❑ REMAIN AS IS �� Z � T❑ ME BE REMOVED T❑ W O z m ALLOW ADDITION �� z 11 � � (E) WIND❑W — m z m TO REMAIN CE) BATH (E) SLIDER J o 00 NO CHANGE NO CHANGE " (E) UTILITYD❑❑R o 11„ 3 W Z (E) SPIRAL STAIR TO BE REPLACE o TO BE REMOVED 30'-4" 3 DECK-2 Q Q 31'-2" X 17'-10" 30'-4" U � - - 5' '-2' (E) WALL cp. 11-411 11 17 TO REMAIN 3-1 7-5 3 266 2-9 2-3 7-11 7-3 242 o DECK - , 1'-5" X 4'-1" DECK-1 �. �.1 21'-3" X 5'-0" (E) SLIDER 3 2430DH 10068 403 RS 2430DH 1006E 4030RS TO BE MADE 3060 prii- TO WINDOW UTILITY ao 21,6 UTILITY co CLOSET ° = Zv ,�„ s 2'-10"X3'-9" CLOSET N -10 X 31- 5'-7" X 6'-0" N '��' S°35'-7° x 6'-0" N o P OPOS D a F RNA E \ 2668 L N 2568 151-211 15'-2"- , - A �, � �° -1 p� MASTER BDRM � � .LoGJ' „ 15'-2" X 22'-0" in til 9 �S�,E / 20,E . _ o cn U- LL Ln W w Lo BATH 0 X-D 10" F - - NEW WALL 9'-0" X 11'-4" - - C] U 'l KITCHEN MASTER BDRM } 20'-11 " X 13'-4" - �� �O O ATH 15'-2" X 22'-0" �, Ln 0° N °O Q a c` ' 0" X 11'-4 -- N N Roo N N w � 21'-5" X 1 '-4" O � O 0 00 boN N 9' 0404 O jox S L__2ea/ o s (E) BATH � HALL NC CHANGE T `HALL .D X 'D IT-2" X 6'-9" f _00� c � (D 04_ N -' - ;T -1 N pss OF 2468 r? 246E �51- O DEN BEL 0C OM I OM I Q °'x cco x � �0�s 2"X10'-1" CLOSET ON ---- ---- -- - �sT O= N T� 2'-6" X 5'-0n H N f N — O �w - � - OPEN B LOW CLOSET BATF � L 10'-2" X 0'-1" 2'-6" X 5'-0" BATH C° - -' .. SSI 4" X 7'- " a, � 6'-4" x 7'-0° `' w w cP �s m % o o �, o��� c DRESSING _ x i n �� a Wx co O N i 8 -3 X 7 -0iizzzzzzzzzzz;j O N c \ p �j F- N N M _ (J? '` F- N N 8'-3" X 7'-0" N - O G 2 206 FX 206 F 206 FX N 206 FX 20 FX 206 FX 0) � A - u N O O -1 (30V �. 2668 a z6ss O O 2668 266s W LncW Z Z O O Q_ a 00 cn N p o W W Ln N (E) FURNACE IN THE ATTIC SPACE o -N❑ CHANGE W (E) FURNACE IN THE ATTIC SPACE co co BEDROOM -N❑ CHANGE x N CIA 16'-11" X 12'-0" - N N N BEDROOM iv V ~ � 16-11" X 12'-0" O0 00 Lu r- N H r-j r i a N M o m Lr O o o � o co M l� 14�aaaaa 306 RS 305 RS 4'-2" 2'-2" 2'-2" 1 _42'-1 " 15'-2" 4'-2" 2'-2" 2'-2" � 2'-1" 15'-2" EXISTING A N D PROPOSED 2ND 9'-10" 2'-11" 2'-6" 17'-3" 3'-3" 9'-10" 2'-11" 2'-6" 17'-3" 3'-3" FLOOR PIAN 35'-9" 35'-9" SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 A=8 EXISTING 2ND FLOOR P LAN 24"x36" SCALE: 1" = 10'-0" 5' 10' 20, 2 PROPOSED 2ND FLOOR P LAN 24"x36" SCALE: 1" = 10'-0" 0 5 10' 20' 11"x17" SCALE: 1" = 20'-0" 1 m m 11"x17" SCALE: 1" = 20'-0" Emol EXISTING FRONT ELEVATION (NO CHANGES) 24"x36" SCALE: 1/4" = 1'-0" 0" 2' 4' 8' I 3 I 1 1 "x 17" SCALE: 1/2" = l'—O" EEEVAT ONS NOTES: PROVIDE TWO LAYERS OF TYPE "D" UNDERLAYMENT AT STUCCO WALLS WHERE THE STUCCO IS APPLIED OVER PLYWOOD SHEATHING. NO EAVE VENTS ARE ALLOWED WHERE SHEAR TRANSFER IS REQUIRED AT FRIEZE BLOCK. PROVIDE GALVANIZED STEEL METAL FLASHING AND COUNTER FLASHING AT ALL ROOF TO WALL AND CHIMNEY INTERSECTIONS AS PER CBC 1503.2, ALSO PROVIDE STEPPED FLASHING WHERE THE SLOPED ROOF ABUTS THE WALL. PROVIDE HIGH RIBBED METAL LATH AT ALL HORIZONTAL STUCCO SURFACES. F� cn Lu >w = Lu w z ILI) U) Lu z a ou E4 vi V) Lu C) Q W EXISTING REAR ELEVATION 24"x36" SCALE: 1/4" = V-0" 2' 4' 1 1 "x 1 7" SCALE: 1/2" = 1'-0" L PROPOSED REAR ELEVATION (N) 24"x36" SCALE: 1/4" = l'—O" 1 1 "x 17" SCALE: 1/2" = l'—O" I ff m !�3i 9 O 00 Ln rn m 1�t o O Ln Lu rn .o z Qua � w un O 0 J z m Lr)r-A �o z m m � O 00 w z O a A Lu O QLn Y U J O ELEVAP ON S 1 SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED PROJECT #: 201711006 A-9 (E) ROOF SHINGLES NO CHANGES w w � � z TOP OF RIDGE _ _ _ O V O V � O O V cn w w cn w cn o z z a a Lu w oc oc EXISTING REAR ELEVATION 24"x36" SCALE: 1/4" = V-0" 2' 4' 1 1 "x 1 7" SCALE: 1/2" = 1'-0" L PROPOSED REAR ELEVATION (N) 24"x36" SCALE: 1/4" = l'—O" 1 1 "x 17" SCALE: 1/2" = l'—O" I ff m !�3i 9 O 00 Ln rn m 1�t o O Ln Lu rn .o z Qua � w un O 0 J z m Lr)r-A �o z m m � O 00 w z O a A Lu O QLn Y U J O ELEVAP ON S 1 SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED PROJECT #: 201711006 A-9 �mm cn LLI00 O 00 rn LLI m � m � O ELEVATIONS NOTES: O Ln W Q Q W Z TOP OF RIDGE — — — — — — — — — — — — – JuQ w PROVIDE TWO LAYERS OF TYPE "D" UNDERLAYMENT AT STUCCO WALLS WHERE THE w Z Z � STUCCO IS APPLIED OVER PLYWOOD SHEATHING. Lu O z o NO EAVE VENTS ARE ALLOWED WHERE SHEAR TRANSFER IS REQUIRED AT FRIEZE BLOCK. V Q PROVIDE GALVANIZED STEEL METAL FLASHING AND COUNTER FLASHING AT ALL ROOF TO 11 Z m z m WALL AND CHIMNEY INTERSECTIONS AS PER CBC 1503.2. ALSO PROVIDE STEPPED 0 00 FLASHING WHERE THE SLOPED ROOF ABUTS THE WALL. 00 2NDFLR. CEILING LVL. PROVIDE HIGH RIBBED METAL LATH AT ALL HORIZONTAL STUCCO SURFACES. L w W Z z O 0 = Q U � 0 50 J 2ND FLR. LVL. 1ST FLR. CEILING LVL. — — — — — — — — — — — — — — 9 - - q (E T Eo II NGE ZO Ln LL t Lu w 1ST.FLR.LVL. v 1'-0" GROUND LEVEL IIIIII C) Q Q 0'-0" A.G.L. O1 � � Q W V � J C CD -I EXISTING LEFT SIDE ELEVATION 24"x36" SCALE: 1/4" = l'–O" ° "x 71 r 1 1 1 7" SCALE: 1/2" l'—O" I (N) TOP OF RIDGE -- — — — — — — — — — — — — — — — — — — — — — — — — ul F- Z H Z Lu � w � Z O � � a O O V O O c/7 Lu w (n w V) � Z Z (N) ROOF SHINGLES, MINIMUM CLASS "C" a a TO MATCH WITH (E) COLOR oc cc (N) RAILING AS PER THE DETAIL SHOWN ON SHEET A13 / SEE STRUCTURAL DRAWINGS. w 00 r -I 00 r -I (V Q N M (N) 2ND FLOOR DECK LEVEL 2. O o 0 N 1ST FLR. CEILING LVL. a a a a a FOR NEW ADDITION I ) HI L U S ]El MATCH NTH ti Ip— cwc RI R DIN C TO ifl oTTI- 70 E=77i WITI (E EXFERICR NO AN ELEVATIONS 2 1 ST.FLR.LVL. I Hi� Hi DATE: 07-10-2018 GROUND LEVELSIGN DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-1 0 PROPOSED LEFT SIDE ELEVATION 24"x36" SCALE: 1/4" = 1'-0" 2' "x 4 8' 1 1 1 1 7" SCALE: 1/2" = 1'-0" I /ni\ — IIKI— — nim — i n KI— EXISTING RIGHT SIDE ELEVATION 24"x36" SCALE: 1/4" = 1'-0" 2' � 7 I 1 1 "x 1 7" SCALE: 1/2" 1' 0" TOP OF RIDGE — — — — — — — — — — — — — — — — — — —— 24'--1 1 " (� 2ND FLOOR DECK LEVEL 2. N 1ST FLR. CEILING LVL. FOR NEW ADDITION 1 ST.FLR.LVL. 1' --0" — — — — — — — — — — — — — — — — — — — GROUND LEVEL 0'-0" A.G.L. PROPOSED RIGHT SIDE ELEVATION (N) ROOF SHINGLES, NO CHANGES 'I- C (N) RAILING AS PER THE DETAIL SHOWN ON SHEET A-13 / SEE STRUCTURAL DRAWINGS. 24"x36" SCALE: 1/4" = V-0" 0" 2' 4 8' 1 1 "x 1 7" SCALE: 1/2" = V-0" -0" 1 r4 vi Lu M Q W cr- CL H H z z Lu Lu z � � 0 0 0 0 0 U LU LU V) V) (A o z z 0 0 CL a Ln cn Lu Lu = w 00 00 Lu � r—I H N r—I Q N M M L!i 0 0 Lu w Ln rn m � Q O Lu 61 lfl z Q U Q LL LLJ Lu Ln >c o c', LL J z m � Lf1 .� (.o z m m O 00 di O A F- CC Lu a U } O Q Ln 01 U CJ CD G ri ELEVATIONS 3 SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-1 0 �mm cl) LU 00 O 00 LU a) a)m Q0 0 cC oLU z LUW Lu z g�Q w3 IL Zz�w� >o W izn) z"D r' � z m m ::) 00 J O 00 00 w Luz z o ° U PiI 0 co I OIL GROUND LEVEL _ 0'-0" A.G.L. O z V W Lu M U Q Q O Ql U } U W J O PROPOSED CROSS SECTION CS -1 SCALE: 1/4" 1' 0" ME 4' 2 rl 11"x36" 11"x17" SCALE: 1/2" = 1'-0" J z z z LU � w � O ~ a o U 0 U 22 U O O cn w z w z O a cn O a cn LU w o Lu H Q 00 N N 00 r- r -I m CO ® m O ui O �aaaaa I ffl is CROSS SECTION r o I 00 SIGN DATE: 07-10-2018 DATE: 3/26/2018 " —J�1'-GROOUND LEVEL 0'-0" A.G.L. SCALE: AS NOTED DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 A-1 2 PROPOSED CROSS SECTION CS -2 SCALE: 1/4" = 1'-0" 0" 2' 4' "x 8' 1 11"x36" 1 1 1 7" SCALE: 1/2" = 1'-0" WINDOW REPLACEMENT REQUIREMENTS: FENESTRATION (WINDOWS) SHALL BE LOW E AND DUAL PANE; AND A MAXIMUM U—FACTOR OF 0.32 AND A MAX. SHGC OF 0.35. (2013 TITLE 24 ENERGY STANDARDS) EMERGENCY EGRESS WINDOWS (BEDROOM ESCAPE WINDOW) SHALL HAVE A MINIMUM OF 5.0 SQUARE FEET OF CLEAR OPENING ON GRADE LEVEL FLOOR AND 57 SQUARE FEET ON SUBSEQUENT FLOORS; AND A MINIMUM CLEAR OPENING WIDTH OF 20 INCHES AND HEIGHT OF 24 INCHES. (CRC 310) GLAZING SHALL BE TEMPERED IF: (CRC R308) LOCATED IN THE WILD—LAND URBAN INTERFACE AREA, LOCATED LESS THAN 60 INCHES MEASURED VERTICALLY, ABOVE WALKING SURFACE OF SHOWER/TUB/STEAM ROOF, ETC., LOCATED IN HAZARDOUS LOCATIONS AS INDICATED PER CRC R308.4. PROVIDE A FALL PREVENTION DEVICE IF THE OPENING IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE AND THE LOWEST PART OF CLEAR OPENING IS LESS THAN 24 INCHES ABOVE FINISHED FLOOR. (CRC R312.2) KITCHEN REMODEL REQUIREMENTS: (2016 CA CODE REQUIREMENTS): KITCHEN DOORS LEADING FROM GARAGE SHALL BE 1-3/8" THICK SOLID WOOD OR HONEY COMB STEEL DOORS OR 20 MINUTE FIRE—RATED DOORS EQUIPPED WITH SELF CLOSING AND SELF LATCHING DEVICES. (CRC R302.5.1). MINIMUM OF 50% OF TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LIGHTING SHALL BE HIGH EFFICACY. (TITLE 24 BUILDING ENERGY EFFICIENCY STANDARDS 150.0 (K)) MINIMUM 30 INCHES CLEARANCE REQUIRED ABOVE KITCHEN RANGE, EXCEPT WHERE 24 INCHES IS ALLOWED PER CODE OR MANUFACTURER'S SPECIFICATION. (CMC 916.1.2) DOMESTIC DISHWASHING MACHINE SHALL NOT BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR FOOD WASTE DISPOSER WITHOUT THE USE OF AN APPROVED AIR GAP FITTING ON THE DISCHARGE SIDE OF THE MACHINE. (CPC 807.4) HOUSEHOLD COOKING APPLIANCES SHALL HAVE VERTICAL CLEARANCE ABOVE THE COOKING TOP OF NOT LESS THAN THIRTY (30) INCHES TO COMBUSTIBLE MATERIAL OR METAL CABINETS. EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND SHALL BE EQUIPPED WITH A BACK DRAFT DAMPER PER CMC SECTION 504.1. ALL RECEPTACLES SHALL BE GFCI PROTECTED AND TAMPER RESISTANT (TR). RECEPTACLES SHALL BE LOCATED SO THAT NO POINT IS MORE THAN 24 INCHES FROM A RECEPTACLE OUTLET MEASURED HORIZONTALLY ALONG THE WALL. RECEPTACLES SHALL BE LOCATED NO MORE THAN 20 INCHES ABOVE COUNTERTOP. ON THE DISCHARGE SIDE OF THE DISHWASHER PROVIDE A LISTED AIR GAP FITTING. LISTED AIR GAPS SHALL BE INSTALLED WITH THE FLOOD LEVEL (FL) MARKING AT OR ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN BOARD WHICHEVER IS HIGHER PER SECTION 807.4. REQUIRED LIGHTING NOTES: ALL LIGHTING TO BE HIGH EFFICACY (I.E. PIN BASED CFL; PULSE START MH, HPS, GU24 SOCKETS OTHER THAN LEDS, LED LUMINAIRES WITH INTEGRAL SOURCE, ETC) CEC TABLE 150.OA. SCREW BASED PERMANENTLY INSTALLED LIGHT FIXTURE MUST CONTAIN SCREW—BASED JAB (JOINT APPENDIX 8) COMPLIANT LAMPS. JAB COMPLIANT LIGHT SOURCES MUST BE MARKED AS JAB—2016" OR "JA8 2016 E" CEC 150.0(K)G. ALL JAB COMPLIANT LIGHT SOURCES IN THE FOLLWOING LOCATIONS ARE CONTROLLED BY VACANCY SENSORS OR DIMMERS. 1) CEILING RECESSED DAM LIGHT LUMINARIES. II) LED LUMINARIES WITH INTEGRAL SOURCES. III) PIN—BASED. LED LAMPS (MR16, AR—III, ETC.,) IV) GO -24 BASED LED LIGHT SOURCES. D) AT LEAST ONE FIXTURE IN EACH BATHROOM CONTROLLED BY A VACANCY SENSOR. CEC 150(K)2J. E) AT LEAST ONE FIXTURE IN EACH LAUNDRY ROOM CONTROLLED BY VACANCY SENSOR. 150(K)2J. F) ALL OUTDOOR LIGHTING AS HIGH EFFICACY WITH MANUAL ON/FF SWITCH AND ONE OF THE FOLLOWING IN ACCORDANCE WITH CEC 150.0(K)3: 1) PHOTO CONTROL AND MOTION SENSOR. II) PHOTO CONTROL AND AUTOMATIC TIME SWITCH CONTROL. III) ASTRONOMICAL TIME SWITCH CONTROL. IV) ENERGY MANAGEMENT CONTROL SYSTEMS. NSULATION NOTES: AFTER INSTALLING INSULATION, THE INSULATION INSTALLER SHALL POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE BUILDER STATING THAT THE INSTALLATION CONFORMS WITH THE REQUIREMENTS OF TITLE 24, PART 2, CHAPTER 2 53, AND THE MATERIALS INSTALLED CONFORM WITH THE REQUIREMENTS OF TITLE 24, CHAPTER 2, SUB CHAPTER 2, ART. 3. THE CERTIFICATE SHALL STATE THE MANUFACTURER'S NAME AND MATERIALS INSTALLED 'R' VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION), THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED DENSITY FOR THE DESIRED R' VALUE. SECTION 1403(d) TITLE 24, CALC. BUILDER SHALL PROVIDE THE ORIGINAL OCCUPANT WITH A UST OF THE HEATING, COOLING, WATER HEATING AND LIGHTING SYSTEMS AND CONSERVATION OR SOLAR DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO USE THEM EFFICIENTLY. SEC. 1403(e) TITLE 24, CALCS. RESIDENTIAL LANDINGS & THRESHOLDS SECTIONS R311.3 & R311.7.6 R311.3 FLOORS AND LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL NO BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION OF 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. EXTERIOR LANDINGS SHALL BE PERMITTED TO HAVE A SLOPE NOT TO EXCESS 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT) R311.3.1 FLOOR ELEVATIONS AT REQUIRED EGRESS DOORS. LANDINGS OR FLOORS AT THE REQUIRED EGRESS DOORS SHALL NOT BE MORE THAN 1 1/2 INCHES LOWER THAN THE TOP OF THE THRESHOLD. EXCEPTION: THE EXTERIOR LANDING OR FLOOR SHALL NOT BE MORE THAN 7 3/4" INCHES BELOW THE TOP OF THE THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. GUARD R. E. (2) 5/8" 0 BOLT SECTION 2x6 DECK 3/4" PRESSURE TREATED PLYWOOD 1/4" JDRAIN-1000 MEMBRANE n (E) Roof Shingles Min. Class C Moisture Barrier 5/8" CDX Plywood Roof Sheathing O.S.B Acceptable 1 x8 Fascia Fascia Gutter --------- (N) Siding 2x6 @ 24" O.C.------------ TO ------- -TO MATCH WITH EXISTING Moisture Barrier (N) 2X6 D.F. P.T. Mu 5% 8" Min ROOF SLOPE AS SHOWN ON PROPOSED PLAN ON SHEET A-2 1/2" Sheetrock 3 1/2" Crown Molding 1/2" Sheetrock 2X6 D.F. Std & Btr. Fire Block (N) R-13 Wall Insulation (E) Roof Rafters 2x6 N o . 2 AT 24"O . C . (E) Ceiling Joists (N) R-30 Roof Insulation TYP. WALL INSULATION SECTION (ONLY FOR 1ST FLR. PROPOSED ADDITION) OPENINGS SHALL N( ALLOW PASSAGE OF 3 1/ 0 SPHEI 2"0 PIPE (Fy=35 KSI) 3 I GUARDRAIL DETAIL ►� 24"x36" SCALE: 1/2" = 1'-0" 0" 1 - 4' 1 1 "x17" SCALE: 1 " = 1'-0" 2 i LU LUV) >w LUZ w z U) z Lu no L4 W 0 Q U W F z z LU w z � � 0 0 0 0 0 V LU V) V) V) o z z 0 0 0- V) N W W CC 00 00 W H N r -I Q N M 0 0 LU cc 0 00 M � 0 0 �Ls W� z Q U Q LL > Ln >'__1 0 O z M L Lr) r -i (.0 z M M 0 0 0 AX F- LU U aLn °' U CJ G 0 FLOOR PLAN NOTES/ DETAILS SIGN DATE: 07-10-2018 DATE: 3/26/2018 SCALE: AS NOTED I DRAWN BY: B.N. CKD BY: PROJECT #: 201711006 A-1 3 CUPERTINO PURPOSE: 2010 CALGREEN RESIDENTIAL CHECKLIST — MANDATORY ITEMS COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building(a.cupertino.org The 2010 CalGreen Code applies to all newly constructed hotels, motels, lodging houses, dwellings, dormitories, condominiums, shelters, congregate residences, employee housing, factory -built housing and other types of swellings with sleeping accommodations and new accessory buildings associated with such uses. Existing site and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGreen. Project Name: 1st & 2nd FLOOR INTERIOR REMODEL Project Address: 1077, MILKYWAY, CUPERTINO,CA 95014 Project Description: 1st & 2nd FLOOR INTERIOR REMODEL Instructions: 1. The Owner or the Owner's agent shall employ a licensed professional experienced with the 2010 California Green Building Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed professional, in collaboration with the owner and the design professional shall initial Column 2 of this checklist, sign and date Section 1 - Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspection by the Building Department, the licensed professional shall complete Column 3 and sign and date Section 2 - Implementation Verification at the end of this checklist and submit the completed form to the Building Inspector. Column 2 Column 3 MANDATORY FEATURE OR MEASURE ProjecVerification LReguiremLentsj 4.201.1 Low-rise residential buildings shall meet or exceed the minimum ., .1 PLANNING AND DESIGN Planning and Design - Site Preservation 4.104.1 A site plan and inventory of the site is developed and used to minimize 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of Environmental Comfort site disturbance in order preserve desirable existing natural resources and ❑X minimize future adverse effects on the proposed structure. ❑X D Planning and Design - Site Development 4.106.2 A plan is developed and implemented to manage storm water 4.507.2. Duct systems are sized and designed and equipment is selected drainage during construction. As of 7/01/2011 using the following methods: 4.106.3 The site shall be planned and developed to keep surface water away ❑X 1. Establish heat loss and heat gain values according to ACCA Manual J or from buildings. Construction plans shall indicate how site grading or a drainage X❑ equivalent. system will manage all surface water flows. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. Page 1 of 5 CalGreen_2010.doc revised 08127111 Indoor Air Quality and Exhaust 4.506.1 Exhaust fans which terminate outside the building are provided in 4.201.1 Low-rise residential buildings shall meet or exceed the minimum ❑ every bathroom. Indoor Water Use 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of Environmental Comfort 4.507.1 Whole house exhaust fans shall have insulated louvers or covers the follow methods. which close when the fan is off. Covers or louvers shall have a minimum ❑X D insulation value of R-4.2. El Water saving fixtures or flow restrictors shall be used per Table 4.303.2. 4.507.2. Duct systems are sized and designed and equipment is selected ElA 20 percent reduction in baseline water use shall be demonstrated per As of 7/01/2011 using the following methods: Table 4.303.1. ❑X 1. Establish heat loss and heat gain values according to ACCA Manual J or 4.303.2 When using the calculation method specified in Section 4.303.1, X❑ equivalent. multiple showerheads shall not exceed maximum flow rates. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit As of 7/01/2011 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and or equivalent. showerheads) shall comply with specified performance requirements. ❑X INSTALLER AND SPECIAL- QUALIFICATIONS Qualifications As of 7/01/2011 702.1 HVAC system installers are trained and certified in the proper installation 4.304.1 Automatic irrigation systems installed at the time of final inspection ❑ of HVAC systems. A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY 702.2 The Licensed Professional responsible to verify CALGreen compliance 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, is qualified and able to demonstrate competence in the discipline they inspect ❑X and verify. against the passage of rodents by closing such openings with cement mortar, Verifications 703.1 Verification of compliance with CALGreen may include construction Interior Moisture Control documents, plans, specifications, builder or installer certification, inspection 4.408.2 Where a local jurisdiction does not have a construction and demolition reports, or other methods acceptable to the enforcing agency which show waste management ordinance, a construction waste management plan shall X❑ substantial conformance. Implementation verification shall be submitted to the be submitted for approval to the enforcing agency. Building Department after implementation of all required measures and prior to Building Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the final inspection approval. building occupant or owner. A4.2 ENERGY General 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. A4.3 WATER EFFICIENCY AND CONSERVATION Indoor Water Use 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of Pollutant Control the follow methods. shall be covered during construction. D El Water saving fixtures or flow restrictors shall be used per Table 4.303.2. ElA 20 percent reduction in baseline water use shall be demonstrated per As of 7/01/2011 Table 4.303.1. ❑X 4.303.2 When using the calculation method specified in Section 4.303.1, X❑ multiple showerheads shall not exceed maximum flow rates. 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit As of 7/01/2011 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with specified performance requirements. ❑X 4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply As of 7/01/2011 Outdoor Water Use 4.304.1 Automatic irrigation systems installed at the time of final inspection ❑ shall be weather -based. A4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY Enhanced Durability and Reduced Maintenance 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, 4.504.5 Particleboard, medium density fiberboard (MDF), and hardwood conduits, or other openings in plates at exterior walls shall be protected plywood used in interior finish systems shall comply with low formaldehyde against the passage of rodents by closing such openings with cement mortar, emission standards. concrete masonry or similar method acceptable to the enforcing agency. Interior Moisture Control Construction Waste Reduction, Disposal and Recycling 4.408.2 Where a local jurisdiction does not have a construction and demolition foundations. waste management ordinance, a construction waste management plan shall X❑ 4.505.3 Moisture content of building materials used in wall and floor framing is be submitted for approval to the enforcing agency. checked before enclosure. Building Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. Page 2 of 5 CalGreen_2010.doc revised 08127111 CALGREEN SIGNATURE DECLARATIONS Project Name: 1st & 2nd FLOOR INTERIOR REMODEL Project Address: 1077, MILKYWAY, CUPERTINO,CA 95014 Project Description: 1st & 2nd FLOOR INTERIOR REMODEL SECTION 1 — DESIGN VERIFICATION Complete all lines of Section 1 - "Design Verification" and submit the completed checklist (Columns 1 and 2) with the plans and building permit application to the Building Department. The owner and design professional responsible for compliance with CalGreen Standards have revised the plans and certify that the items checked above are hereby incorporated into the project plans and will be implemented into the project in accordance with the requirements set forth in the 2010 California Green Building Standards Code as adopted by the City of Cupertino. Owner's Signature Date Owner's Name (Please Print) VAMSIDHAR GUNTURU & SUNAYANA GUNTURU Design Professional's Signature Date JF CONSULTING DESIGN & ENGINEERING Design Professional's Name (Please Print) Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance SECTION 2 — IMPLEMENTATION VERIFICATION Complete, sign and submit the competed checklist, including column 3, together with all original signatures on Section 2 to the Building Department prior to Building Department final inspection. I have inspected the work and have received sufficient documentation to verify and certify that the project identified above was constructed in accordance with this Green Building Checklist and in accordance with the requirements of the 2010 California Green Building Standards Code as adopted by the City of Cupertino. Signature of License Professional responsible for CalGreen compliance Date Name of License Professional responsible for CalGreen compliance (Please Print) Phone Email Address for License Professional responsible for CalGreen compliance Page 4 of 5 CalGreen_2010.doc revised 08127111 Page 5 of 5 CalGreen_2010.doc revised 08127111 A4.5 ENVIRONMENTAL Fireplaces 4.503.1 Install only a direct -vent sealed -combustion gas or sealed wood - burning fireplace, or a sealed woodstove. Pollutant Control 4.504.1 Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1 Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. ❑X 4.504.2.3 Aerosol paints and other coatings shall be compliant with product X❑ weighted MIR Limits for ROC and other toxic compounds. 4.504.2.4 Documentation shall be provided to verify that compliant VOC limit finish materials have been used. 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. ❑X 4.504.4 Fifty (50) percent of floor area receiving resilient flooring shall comply with the VOC-emission limits defined in the Collaborative for High Performance Schools (CHIPS) Low -emitting Materials List or be certified under the Resilient Floor Covering Institute (RCFI) FloorScore program. 4.504.5 Particleboard, medium density fiberboard (MDF), and hardwood plywood used in interior finish systems shall comply with low formaldehyde OX emission standards. Interior Moisture Control 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. OX 4.505.3 Moisture content of building materials used in wall and floor framing is checked before enclosure. Page 3 of 5 CalGreen_2010.doe revised 08127111 H LU >w LUz zw Z LU os L4 O 00 0) m 0 0 LL] C lD z Q U Q o' LL LLJ LU Ln >� O O z m L ern Q r-1 t.0 z m m O 00 � w z O a LU O U z z � W or_ 0 w a W U } o Q Ln LU Q U J cn � Y r\ Q O C) z z LU LU z � � O O O ~ U U C1. O O U cn w w LU V) cn o z z a a cn cn � CC 00 00 LU i Q N cn O M Lr O O W CC CAL GREEN CHECKLIST SIGN DATE: 07-09-2018 DATE: 3/26/2018 SCALE: AS NOTED DRAWN BY: B. N. CKD BY: PROJECT #: 201711006 A-1 4