Loading...
Approved Plan Set_4.pdfCom nunity Development Department tanning Division - Cupertino I. FACE OF BUILDING 4x4 POST @ 6-0" O.C. MAX. A1.1 COVER SHEET / SITE PLAN CUPERTINO APPROVED Case # RM -2018-10 Application Number(s) 2x4 RAILS - 3 Approval Bo y: Director / Staff Approva I Da a 10/01/18 Erick Serrano Signature Case Manager 2x4 GATE RAILS FRAMING I. FACE OF BUILDING 4x4 POST @ 6-0" O.C. MAX. MIN. 2% DRAINAGE SLOPE AWAY FROM ADDITION ENCLOSE(E)SUN ROOM INTO LIVING SPACE - (E) FENCE & GATE TO REMAIN. SEE DETAIL 2/A1.1 0 a) SITE PLAN LEGEND F77771 BLDG.STRUCTURE CONCRETE PAVING PERVIOUS PAVERS -- PROPERTY LINE - - - - - - - SETBACK LINE (E) WD. FENCE ALL (E) TREES TO REMAIN 2 TOTAL 67' -- -- -- -- -- -- - -- -- -- \\ o LU \ in a. - - - - - - ------------------ ---- - -------- 5'-0" WIRE \ CLEARANCE \ EASEMENT-\ -----------\--------------- ---- o 0 \ N \ co \ \ (N) 2 BAY WINDOWS N I \I \ �(E) OVERHEAD WIRES (E) CONC. PAID..,\ \ (E) ELECT. METER ,------------- --- - ---- ---- \ \ (N) AC (N) D.S. \ I I I I I I I ONE-STORY HOME II 5'-0.. I o rn ii PROJECT DIRECTORY KONDO RESIDENCE ADDITION ;Jp DAVISON AV AVENUE E THAM no 1 0500 U Design and Planning CUPERTINO CA 95014 8693 Pacific Hills Way 7 Sacramento, CA 95828 916-662-5580 www.td-arch.com DRAWING INDEX PROJECT DATA OWNER / APPLICANT A1.1 COVER SHEET / SITE PLAN MR. & MRS. ALAN KONDO A2.1 (E) / DEMO FLOOR PLAN AVENUE A2.2 (N) FLOOR PLAN & ROOF PLAN I 2x4 RAILS - 3 L. (40 ) 88 -6 TEL. (408) 888-6920 A3.1 ELEVATIONS & SECTIONS kondoa@yahoo.com REQUIRED I I I 2x4 GATE RAILS FRAMING I I I I I I I l I i 1x6 ONE SIDE OF FENCE I I 1 I I I i I i t t ALONG STREET SIDE I I I I I I I I i i t i I GALVINIZED PAIR HINGES I I i I & LATCH II I� I I l I I N J I I° I G 'I FINISH GRADE i l I U I .1 1.. 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE II I,...I Cl) 12"0 x 36" DEEP ILJ °1 I. I- -1 :°1 LJ CONCRETE FOOTING. L'-.--3 L-:--9 L'-:--3 SLOPE AWAY FROM 5. REMODEL MASTER BATH (60 S.F.) POST AT CONC. TOP (E) WOOD FENCE & GATE 3/8"=1'-0" MIN. 2% DRAINAGE SLOPE AWAY FROM ADDITION ENCLOSE(E)SUN ROOM INTO LIVING SPACE - (E) FENCE & GATE TO REMAIN. SEE DETAIL 2/A1.1 0 a) SITE PLAN LEGEND F77771 BLDG.STRUCTURE CONCRETE PAVING PERVIOUS PAVERS -- PROPERTY LINE - - - - - - - SETBACK LINE (E) WD. FENCE ALL (E) TREES TO REMAIN 2 TOTAL 67' -- -- -- -- -- -- - -- -- -- \\ o LU \ in a. - - - - - - ------------------ ---- - -------- 5'-0" WIRE \ CLEARANCE \ EASEMENT-\ -----------\--------------- ---- o 0 \ N \ co \ \ (N) 2 BAY WINDOWS N I \I \ �(E) OVERHEAD WIRES (E) CONC. PAID..,\ \ (E) ELECT. METER ,------------- --- - ---- ---- \ \ (N) AC (N) D.S. \ I I I I I I I ONE-STORY HOME II 5'-0.. I o rn ii PROJECT DIRECTORY KONDO RESIDENCE ADDITION ;Jp DAVISON AV AVENUE E THAM no 1 0500 U Design and Planning CUPERTINO CA 95014 8693 Pacific Hills Way 7 Sacramento, CA 95828 916-662-5580 www.td-arch.com DRAWING INDEX PROJECT DATA OWNER / APPLICANT A1.1 COVER SHEET / SITE PLAN MR. & MRS. ALAN KONDO A2.1 (E) / DEMO FLOOR PLAN AVENUE A2.2 (N) FLOOR PLAN & ROOF PLAN UPS TINOON CUPERTINO,95014 C L. (40 ) 88 -6 TEL. (408) 888-6920 A3.1 ELEVATIONS & SECTIONS kondoa@yahoo.com DESIGNER THAM DO 8693 PACIFIC HILLS WAY SACRAMENTO, CA 95828 TEL. (916) 662-5580 BRYAN DO, LEED AP bryan@td-arch.com APPLICABLE CODES: 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA RESIDENTIAL CODE 2016 CALIFORNIA MECHANICAL CODE 2016 CALIFORNIA PLUMBING CODE 2016 CALIFORNIA ELECTRIC CODE 2016 CALIFORNIA FIRE CODE 2016 CALIFORNIA ENERGY CODE 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE CITY OF CUPERTINO MUNICIPAL CODES PROJECT DESCRIPTION: 1. REMOVE EXISTING REAR SUN ROOM (192 S.F.) 2. NEW REAR ADDITION (138 S.F.) 3. NEW BAY WINDOWS (2) 4. REMODEL KITCHEN (209 S.F.) 5. REMODEL MASTER BATH (60 S.F.) 6. REMODEL LIVING SPACE (530 S.F.) 7. REMODEL GARAGE (414 S.F.) 8. RE -ROOF HOUSE (2,330 S.F.) 9. REMOVE STUCCO AND PLACE SIDING (1,569 S.F.) 10. REPLACE WINDOWS (3) 11. REPLACE GARAGE DOOR AND SPRING 12. ADD NEW RECESSED LIGHTS (19 TOTAL) (N) D.S. AND 13. ADD NEW RECEPTACLES (19 TOTAL) SPLASH BLOCK, 14. ADD NEW FANS (2) TYP. U.N.O. 15. ADD NEW FIRE SPRINKLER SYSTEM NFPA 13D 16. REPLACE INSULATION: R-30 AT CEILING, R-15 AT WALL, AND R-19 AT CRAWL SPACE. (E) FENCE & GATE TO REMAIN. SEE 10'-0" DETAIL 2/A1.1 I I I 1 (E) GAS METER (E) PORCH (N) CLEANOUT, 2' FROM (N) D.S. 1 O I FOUNDATION II I (E) TREE I REPLACE(E)CONCRETE DRIVEWAY W/ PERVIOUS PAVERS I II c0I l� (E) GAS LINE Q I I I 1 0 I If� (E) WATER LINE DRIVEWAY � C? I J I - (E) LANDSCAPING o 1 LU I I I 9 I (E) SEWER LINE INEW PLCO PER DISTRICT I I STANDARDS I II 67' (E) SIDEWALK (E) CONCRETE PAVING TO REMAIN (E)TREE SITE PLAN DAVISION AVENUE 1/8"=11-011 0 2' 4' 8' V GENERAL NOTES: 1. DIMENSIONS: A. IT SHALL BE THE CONTRACTOR'S AND/OR THE APPLICABLE SUBCONTRACTOR'S RESPONSIBILITY TO VERIFY ALL DIMENSIONS SHOWN ON THE DRAWINGS WITH RELATED REQUIREMENTS OF THE STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND LANDSCAPE DRAWINGS. NOTIFY OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK. B. USE DIMENSIONS SHOWN RATHER THAN SCALING DRAWINGS. C. ALL DIMENSIONS TO EXTERIOR WALLS ARE TO FINISHED FACE OF EXTERIOR WALLS, U.N.O. D. ALL DIMENSIONS TO INTERIOR WALLS ARE TO THE FACE OF STUD, U.N.O. E. DIMENSIONS TO CENTER ARE SHOWN WITH CENTERLINE (LINE INTERRUPTED WITH ONE DOT) OR NOTED WITH F. CEILING HEIGHT DIMENSIONS ARE FROM UNFINISHED FLOOR TO FRAMING FACE OF CEILING. G. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD BEFORE PROCEEDING WITH THE WORK. H. ALL DOORS NOT LOCATED BY DIMENSION ON PLAN OR DETAIL SHALL BE 4" (FOUR INCHES) FROM FACE OF STUD TO FACE OF NEAREST DOORBUCK OR CENTERED ON ROOM. I. DOOR SIZES INDICATED ON DRAWINGS ARE OPENING DIMENSIONS; ALLOWANCES FOR THRESHOLDS, JAMB, ETC. SHALL BE TAKEN FOR NET DOOR SIZES. 2. PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING AND FRAMING NOT NECESSARILY LIMITED TO THE INSTALLATION OF LIGHT FIXTURES, AND TOILET ACCESSORIES AND BRACKETS. 3. PROVIDE SOLID BLOCKING BEHIND ALL BATHROOM ACCESSORIES. 4. DETAILS MARKED TYPICAL (TYP.) SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. 5. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES OF CONSTRUCTION ON THIS PROJECT. 6. ANY QUESTION REGARDING THIS DRAWING DOCUMENT, THE CONTRACTOR AND/OR THE APPLICABLE SUB CONTRACTOR SHALL CONTACT DIRECTLY TO OWNER. OWNER THEN CONTACT THE DESIGNER IN WRITING. THE DESIGNER IS NOT IN CONTRACT TO PERFORM CONSTRUCTION ADMINISTRATION. 7. IN CASE OF DISCREPANCY CONCERNING DIMENSIONS, QUANTITIES, AND LOCATION, THE CONTRACTOR AND/OR THE APPLICABLE SUB CONTRACTOR SHALL, IN WRITING, CONTACT THE OWNER ANY DISCREPANCIES BETWEEN PLANS, DETAILS, OR SCHEDULES. THE OWNER THEN CONTACTS THE DESIGNER USING WRITTEN FORMS SUCH AS RFI (REQUEST FOR INFORMATION) OR CLARIFICATION. THE DESIGNER THEN RESPONDS TO THOSE RFI OR CLARIFICATION IN WRITING. THERE SHALL BE NO ADJUSTMENT TO THE COST OF THE WORK RESULTING FROM SUCH CLARIFICATION OF DISCREPANCIES. 8. FAILURE TO REPORT A CONFLICT IN THIS DRAWING DOCUMENT SHALL BE DEEMED EVIDENCE THAT THE CONTRACTOR AND/OR THE APPLICABLE SUBCONTRACTOR HAS ELECTED TO PROCEED IN THE MORE EXPENSIVE MANNER. 9. THE CONTRACTOR AND/OR THE APPLICABLE SUBCONTRACTOR SHALL INVESTIGATE, VERIFY AND BE RESPONSIBLE FOR ALL CONDITIONS AND DIMENSIONS OF THE PROJECT AND SHALL NOTIFY THE DESIGNER ABOUT CONDITIONS REQUIRING MODIFICATIONS BEFORE PROCEEDING THE WORK. 10. CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY AND CONSTRUCTION METHOD 11. FINAL APPROVAL IS DEPENDENT UPON FIELD INSPECTIONS AND/OR ANY NECESSARY ACCEPTANCE TESTS. 12. CONSTRUCTION SITE FIRE SAFETY: ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF THE CFC CHAPTER 33 AND FIRE DEPARTMENT STANDARD DETAIL AND SPECIFICATION SI -7 13. ADDRESS IDENTIFICATION: THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS. NUMBERS SHALL BE A MINIMUM OF 4" HIGH WITH A MINIMUM STROKE WIDTH OF 0.5" VICINITY MAP N.T.S. ADDRESS: APN: ZONING: TYPE OF CONSTRUCTION: OCCUPANCY GROUP: NET LOT SIZE (SAME AS GROSS): MAX. SITE COVERAGE: ADD'L PORCH / ROOF COVERAGE F.A.R.: FIRE SPRINKLERS: EXISTING USE: PROPOSED USE: FLOOD ZONE: MAX. BLDG. HEIGHT: BLDG. HEIGHT: SETBACK: 10500 DAVISON AVENUE CUPERTINO, CA 95014 369-26-033 R1-10 V -B, FULLY SPRINKLERED R -3/U 6,030 SF. 2,714 SF. (45%) 301 SF. (5%) 2,714 SF. (45%) YES. NFPA 13D ONE STORY HOUSE, SFD ONE STORY HOUSE, SFD 3 BED / 2 BATH AH 13.7 (NAVD88) 28'-0" 15'-4" (E) FRONT: 20'-0" 16-0" (E) REAR: 20'-0" 25-6" (E) RIGHT: 5'-0" 5-0" (E) LEFT: 10'-0" 6'-11" (E) AREA CALCULATIONS: EXISTING: (E) HOUSE: 1,381 SF. (E) ATTACHED GARAGE: 432 SF. (E) TOTAL: 1,813 SF. (E) COVERED PORCH: 61 SF. (E) REAR COVERED SUNROOM: 138 SF. (E) ROOF OVERHANG: 320 SF. EXISTING FAR: 1,813 / 6,030 = 30.1% (45% MAX.) EXISTING LOT COVERAGE: 1,813 / 6,030 = 30.1% (45% MAX.) EXISTING PATIO / PORCH / ROOF OVERHANG COVERAGE: 519 / 6,030 = 8.6% (5% MAX.) PROPOSED NEW: (N) HOUSE: 1,519 SF. (E) ATTACHED GARAGE: 432 SF. (E) TOTAL: 1,951 SF. (E) COVERED PORCH: 61 SF. (E) ROOF OVERHANG: 320 SF. THE EXISTING GARAGE WITH CLEAR INTERIOR DIMENSIONS OF 17'-11"X20'-1" IS A LEGAL NON -CONFORMING GARAGE PER CITY MUNICIPAL CODES CHAPTERS 19.124.130.A.5 & 19.124.130.A.6. TO ACCOMMODATE A CONFORMING GARAGE (20'X20' CLEAR) THE GARAGE IS REQUIRED TO BE 2'-2" WIDER. THIS DIMENSION IS REQUIRED TO RESERVE FOR FUTURE GARAGE UPGRADE. FOR FAR CALCULATION, THIS RESERVATION EQUAL TO 45 SQUARE FEET (2'-2"X20'-8" = 45 SF.) PROPOSED FAR: 1,951 / 6,030 = 32.4% PROPOSED FAR WITH CONFORMING GARAGE: (1,951 + 45) / 6,030 = 33.1% (45% MAX.) ALLOWABLE OVERHANG COVERAGE: 5% OR 301 SF. PROPOSED PORCH AND ROOF OVERHANG: 381 SF. (6.3%) 381 - 301 = 80 SF. TO BE COUNTED TOWARD LOT COVERAGE PROPOSED LOT COVERAGE: (1,951 + 80 + 45) / 6,030 = 34.4% (45% MAX.) MAXIMUM IMPERVIOUS FRONT YARD AREA: 40% PROVIDED IMPERVIOUS PAVING IN FRONT YARD: 0% PROVIDED PERVIOUS PAVERS IN FRONT YARD: 43.3% w n La Mar Dr L2 Mar Dr L➢ 3 Somerset Dr co n r It �' ET r a ro cL ro A a,��TOe � oaw Dr Pacifica Dr cn dye CGftordpr y-�'e Qfi Suisun Dr p cCrff-0rar ��g CfP��,y��e m KLIU > m tie 3� u Vicksb4f� r?r Qv' �7 C' Ilrcksbusrh 1 _Qreekstdp__ G? La 44ar [1r Y y m y �l�eyL��e P Spf� oar � pie �a cfTf y � ora4r ti`b�� �� PROJECT Park First apti5l Church lot Cuperrina a' N 1011 a Phil Ln 4�-4t4erwoodAve AlherwoodAve a p o a+ w � U � OiSfley 0 0 This document contains information proprietary to THAM DO. The use of this document shall be restricted to the specific project. This documents or its contents may not be reproduced or disclosed to others without prior written consent of Bryan Do. All rights reserved. Copyright THAM DO. Revisions /i COMMENTS FROM PLANNING DEPT. 8-22-2018 Project KONDO RESIDENCE ADDITION Mr. & Mrs. KONDO 10500 DAVISON AVENUE CUPERTINO, CA 95014 APN: 369-26-033 Drawing COVER SHEET SITE PLAN Proj. No. 17042 Drawn BTD Date 6-7-18 Scale AS NOTED Sheet A1.1 CUPERTINC Case # Appro� Approx, Signah Com nunity Development Department tanning Division - Cupertino CUPERTINO APPROVED Case #- RM -2018-1 O Application Numbeks 4 6 7 Approval Bo y: Director / StFI�L - - - - - - - - - - - - Approva I Da a 10/01/18 Signature Erick Serrano I Case Mana er I I 10 II 1 3 O I F_ -1 R I I V--- 0 I I $ I 1 3 I 6 R I 4 I I I 0 I I I I n74= ==L --------------- 7 4 ROOF PLAN GENERAL ROOF NOTES 1. ROOF UNDERLAYMENT: FOR ROOF SLOPE 4:12 OR MORE, ONE LAYER OF #30 ASPHALT -SATURATED FELT, ASTM D226. WEATHER LAP EDGES 2 INCHES MINIMUM. LAP ENDS 4 INCHES MINIMUM; STAGGER END LAPS IN SUCCESSIVE COURSES 6 FEET MINIMUM. TURN UPGROUND AT SIDEWALLS. FOR ROOF SLOPE LESS THAN 4:12, PROVIDE TWO LAYERS OF #15 ASPHALT -SATURATED FELT 2. PLUMBING AND VENT JACKS: GALVANIZED STEEL WITH NEOPRENE GASKETS; PAINT TO MATCH ROOFING COLOR. WEATHER LAP WITH UNDERLAYMENT. 3. METAL FLASHING: GALVANIZED STEEL OR COPPER, 26 GAGE THICKNESS. PAINT EXPOSED FLASHING TO MATCH ADJACENT COLOR. ROOF KEYNOTES 1. ROOF SLOPE: (E) 5:12, TYP., U.O.N 2. ROOF SLOPE: (E) 3:12 AS INDICATED 3. ROOF MATERIAL: REMOVE (E) WOOD SHAKE ROOFING TO CLASS W ROOFING. SEE ELEVATIONS 4. (E) 18" EAVE AND RAKE, U.O.N. 5. SKYLIGHT. SEE FLOOR PLAN. MIN. 10' CLEAR FROM OPERABLE SKYLIGHTS AND ANY FRESH AIR INTAKES ON ROOF TO ALL TYPES OF VENTS 6. OGEE GUTTER 7. DOWNSPOUT 8. PROVIDE 26 GA. G.I. VALLEY FLASHING AT ALL ROOF VALLEYS TYP. 9. ATTIC ACCESS, SEE FLOOR PLAN 10. LINE OF WALL BELOW T =RM T: TRANSITION R: RIDGE V: VALLEY m%- _INE 1/8"= 1 1-011 IR ' CV N Eo v co ROOF VENT CALCULATIONS PER CRC R806.2 ATTIC VENTILATION VENTILATION PROVIDED AREA REQUIRED LOWER VENTILATION UPPER VENTILATION TOTAL 1/300 (MIN. 50%) (MIN. 40%, MAX. 50%) 14.7 SQ. IN. 72 SQ. IN. TOTAL LOWER 72 SQ. IN. TOTAL UPPER EAVE VENT O'HAGIN ROOF VENTILATION O'HAGIN ROOF VENTILATION BLOCK VENT VENT 1,952 SF.576 937 SQ. IN. 0 8 SQ. IN. 6 432 SQ. IN. 1,008 SQ. IN. 61% 46% 108% ALTERNATE 1 INTAKE POWERED VENT 1 EXHAUSTED POWERED VENT ROOF VENT NOTES 1. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE PER CRC R806.2 EXCEPTION 2 2. CONTRACTOR TO VERIFY NET FREE VENTILATION AREA AND RECALCULATE AS REQUIRED 3. ROOF MOUNTED VENTS TO BE LOW -PROFILED O'HAGIN ROOF VENTS OR EQUAL 4. PROVIDE TWO 72 SQ. IN. O'HAGIN ROOF VENTS FOR COMBUSTION AIR FOR ATTIC FURNACE 111 11 1/011 A'V 1 1 PYI N) FLOOR PLAN 1/4"= 1 '-0" 0 1' 2' 4' N N) FLOOR PLAN LEGEND: (E) WALL TO REMAIN (E) WALL TO BE REMOVED SHOWN (N) FLOOR PLAN FOR REFERENCE ONLY (N) 2x4 STUD WALL (N) 2x6 STUD WALL (x-) FLOOR PLAN KEYNOTES: 1. 1 3/4" SOLID CORE ENTRY DOOR W/ WEATHER STRIP. DOOR TO BE OPERABLE FROM THE INSIDE OF THE HOUSE WITHOUT USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT 2. 1 3/8" SOLID CORE SELF CLOSER, SELF -LATCHING, RATED GARAGE/HOUSE DOOR, W/ WEATHER STRIP 3. (E) GAS METER - SEE SITE PLAN 4. (E) ELECTRIC METER - SEE SITE PLAN 5. CONCRETE OR PAVER WALK, OR MIN. 36"X36" CONCRETE LANDING, 7-3/4" MAX. TO THRESHOLD AT IN -SWING OR SLIDING DOOR. SEE SITE PLAN. 6. (E) FENCE AND GATE. SEE SITE PLAN 7. (E) 50 GALLON WATER HEATER ON 18" HT. PLATFORM 8. (E) FURNACE 9. ENERGY STAR WASHER 10. DRYER WITH DUCT THROUGH WALL 11. NOT USED 12. MIN. 1/2" GYP. BD. AT GARAGE WALLS AND CEILING 13. 36" GAS COOKTOP - W/ HOOD VENT THROUGH WALL 14. 36" REFRIGERATOR / FREEZER - PLUMB FOR ICE MAKER 15. 36" KITCHEN SINK 16. ENERGY STAR DISHWASHER PER CGBSC A4.303.3 17. TRASH COMPACTOR 18. QUARTZ OR SOAPSTONE COUNTERTOP THROUGHOUT KITCHEN, ISLAND 19. LINE OF CABINET ABOVE 20. 12" COUNTER OVERHANG 21 • WATER FILLER 22. PANTRY W/ 5 SHELVES 23. MEDIA CABINET 24. WATER CLOSET W/ MIN. 30" WIDE X 24" CLEARANCE IN FRONT, MAX. 1.28 GPF, VENT THRU ROOF 25. FULL HIGH TILE OR SOLID SURFACE SHOWER W/ TEMP. GLASS ENCLOSURE. SHOWER COMPARTMENT TO HAVE A MIN. INTERIOR FLOOR AREA OF 1,024 SQ.IN. AND CAPABLE OF ENCOMPASSING 30" CIRCLE 26. LAVATORY, MEDICINE CABINET, MIRROR, MARBLE OR GRANITE COUNTERTOP. PROVIDE TOWEL BAR, TOWEL RING AND OTHER BATH ACCESSORIES PER OWNER DIRECTION 27. 1 SHELF AND 1 POLE, OR CUSTOM SHELVES PER OWNER'S DIRECTION 28. (E) ATTIC ACCESS 29. (E) 18"X24" CRAWLSPACE ACCESS 30. 4 SKYLIGHTS FITTED IN BETWEEN (E) TRUSSES. VELUX SKYLIGHT MODEL VSE C06 (21"X46") ELECTRIC OPERABLE 31. 1 SKYLIGHT FITTED IN BETWEEN (E) TRUSSES. VELUX SKYLIGHT MODEL VSE C01 (21"X27") ELECTRIC OPERABLE 32• WHOLE HOUSE FAN 33. HOT WATER RECIRCULATOR 34. REQUIRED VEHICLE BOLLARD 35. AIR CONDITIONER ON CONCRETE PAD 36. CONCRETE STEPS. (2) 11" TREADS, (3) 6" RISERS (7-3/4" MAX.) FLOOR PLAN GENERAL NOTES: A. TUB/SHOWER.- 1. UB/SHOWER:1. DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES AND ADJACENT WALL OPENINGS WITHIN 60" ABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC 2. SHOWERS SHALL BE FINISHED WITH A SMOOTH, HARD, NONABSORBENT SURFACE OVER A MOISTURE RESISTANT UNDERLAYMENT TO A HEIGHT OF 72" ABOVE THE DRAIN INLET 3. PROVIDE WATER RESISTANT GYPSUM COMPLYING W/ASTM C 630 BEHIND PREFAB FIBERGLASS BATH/SHOWER. 4. PROVIDE BACKING BEHIND TUB AND SHOWER. B. GLAZE WITHIN DOOR TO BE TEMPERED. MAX. THRESHOLD HEIGHT OF EXTERIOR SLIDING OR IN -SWING DOOR TO BE 7-3/411 . MAX. THRESHOLD HEIGHT OF EXTERIOR OUT -SWING DOOR TO BE 1/2". MINIMUM LANDING IS 36"X36" MAXIMUM DOOR OPENING EFFORTS SHALL BE: 8-1/2 Ib. EXTERIOR, 5 Ib. INTERIOR. C. WINDOWS TO BE DOUBLE PANE, LOW -E, TEMPERED GLASS INDICATED AS "TEMP." ON FLOOR PLANS. D. PROVIDE SAFETY GLAZING FOR ALL GLAZING IN HAZARDOUS LOCATIONS E. EMERGENCY EGRESS WINDOW INDICATED AS "EE" NEXT TO WINDOW SIZE ON FLOOR PLANS. OPENING OF THE WINDOW TO BE MINIMUM NET CLEAR OPENING OF 5.7 S.F., MIN. NET CLEAR OPENING HEIGHT OF 24" AND WIDTH OF 20". EMERGENCY EGRESS WINDOW HEIGHT TO BE MAXIMUM 44" FROM FLOOR TO BOTTOM OF CLEAR OPENING. EMERGENCY EGRESS WINDOW TO OPEN DIRECTLY TO THE STREET, PUBLIC ALLEY, AND YARD OR EXIT COURT FOUNDATION VENT CALCULATIONS: ADDITION CRAWLSPACE: 138 SF. VENTING REQUIRED: 138/150 = 130 SQ. IN. VENTING PROVIDED: EACH VENT: 5-3/4"x14-1/2" x 80% = 66 SQ. IN. NET FREE VENTILATION AREA. CONTRACTOR TO VERIFY NET FREE VENTILATION AREA AND RECALCULATE IF REQUIRED TOTAL NUMBER OF NEW VENTS PROVIDED: 2 2x66 = 132 SQ. IN. > 132 SQ. IN., OK. VENT SCREEN TO BE CORROSION -RESISTANT, NONCOMBUSTIBLE WIRE MESH WITH MAX. 1/4" OPENINGS, ONE VENT WITHIN 3'-0" OF EACH CORNER OF BUILDING. CRC 408.1 CONTRACTOR TO VERIFY VENTILATION FOR ENTIRE HOUSE OF 1,519 SF. OF CRAWLSPACE TO MEET REQUIREMENTS. REPAIR OR REPLACE (E) VENTS AS REQUIRED FA THAM DO Design and Planning 8693 Pacific Hills Way Sacramento, CA 95828 916-662-5580 www.td-arch.com This document contains information proprietary to THAM DO. The use of this document shall be restricted to the specific project. This documents or its contents may not be reproduced or disclosed to others without prior written consent of Bryan Do. All rights reserved. Copyright THAM DO. Revisions /i COMMENTS FROM 2ND PLAN CHECK. 8-22-2018 Project KONDO RESIDENCE ADDITION Mr. & Mrs. KONDO 10500 DAVISON AVENUE CUPERTINO, CA 95014 APN: 369-26-033 Drawing (N) FLOOR PLAN & ROOF PLAN Proj. No. 17042 Drawn BTD Date 6-7-18 Scale AS NOTED Sheet A2.2 Community Development Department Planning Division — Cupertino 'CUPERTIN4 APPROVED Case # RM -2018-10 Application Number(s) Approval Bo y: Director/ Staff Approval Dae 10/01/18 Signature Erick Serrano SECTION :6] SECTION 1/211=11-011 AT BAY WINDOWS ,qFC;TION NOTES - PROVIDE 2x FIRE BLOCKING IN CONCEALED SPACED OF STUD WALLS AND PARTITIONS AT 10' INTERVALS HORIZONTAL, AND IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEY. INSULATION: - HOUSE & GARAGE CEILING: R-30 BATT - FLOOR: R-19 BATT - 2x4 EXTERIOR WALLS: R-15 BATT - 2x6 EXTERIOR WALLS: R-19 BATT FRONT / NORTH ELEVATION REAR / SOUTH ELEVATION j LEFT / EAST ELEVATION 1/411=11-011 ELEVATION KEYNOTES: 1. REMOVE (E) WALL FINISH TO WALL SHEATHING. PROVIDE HARDIE PANEL AND BATTENS O/ 2 LAYERS OF 60 MINUTE FA GRADE D BLDG. PAPER 2. (N) WALL HARDIE PANEL AND BATTENS O/ 2 LAYERS OF 60 MINUTE GRADE D BLDG. PAPER, TYP. THAM DO 3. REPLACE (E) WOOD SHAKE ROOFING W/ (N) COMPOSITION Design and Planning SHINGLE ROOFING 4. REPLACE (E) ATTIC VENTILATION 8693 Pacific Hills Way Sacramento, CA 95828 5. REPLACE (E) CRAWLSPACE VENTS. 916-662-5580 S. (N) CRAWLSPACE VENTS www.td-arch.com 7. (N) WOOD MOLDING AND DENTILS This document contains information proprietary to THAM DO. The use of this document shall be restricted to the specific project. This documents or its contents may not be reproduced or disclosed to others without prior written consent of Bryan Do. All rights reserved. Copyright THAM DO. O \ N \ PLATE kms, 1 I-- x 1 v IN -1-1 N (E) CORNER POST TO REMAIN 1/4"=1 1-011 I LU Z_ J Ir o IW o n O RIGHT / WEST ELEVATION 1/411=11-011 0 1' 2 4' Revisions Project KONDO RESIDENCE ADDITION Mr. & Mrs. KONDO 10500 DAVISON AVENUE CUPERTINO, CA 95014 APN: 369-26-033 Drawing ELEVATIONS & SECTIONS Proj. No. 17042 Drawn BTD Date 6-7-18 Scale AS NOTED Sheet A3.1