COVER SHEET
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
1 0 592 J O HA N S EN A V E.
C UPERTI NO, CA
LOCAL TABLES / NOTES:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
ABV.Above
A/C Air Conditioner
A.D.Access Door
ADD.Addition
A.F.F.Above Finished Floor
A.F.G.Above Finished Grade
B.L.Building Line
BLDG.Building
B.O.Bottom of
BTM.Bottom
CABT.Cabinet
C.D.Construction document
C.L.Center Line
CL.Closet
CLG.Ceiling
C.O.Clean Out
CONC.Concrete
D.S.Down spout
D/W Dishwasher
DBL.Double
DEMO.Demolition
DIA.Diameter
DR.Door
ELEV.Elevation
EXIST.Existing
EXT.Exterior
ABBREVIATIONS:
SHEET TITLE:
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT
TO THE BODESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY BODESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM BODESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
DESIGN
A-00.01:COVER SHEET
1-1:BOUNDARY AND TOPOGRAPHIC MAP
2-1:BOUNDARY AND TOPOGRAPHIC MAP
L-1:IRRIGATION PLAN
L-2:PLANTING PLAN
L-3:IRRIGATION& PLANTING DETAILS
RA-01.01:EXISTING FLOOR PLAN
A-01.01:PROPOSED SITE PLAN
A-01.02:PROPOSED FLOOR PLAN
A-02.01:PROPOSED ELEVATIONS
A-02.02:PROPOSED ELEVATIONS
A-03.01:PROPOSED SECTION & STREETSCAPE ELEVATION
A-06.01:FLOOR AREA DIAGRAM + SCHEDULES
OWNER:ABU WAWDA
10592 JOHANSEN AVE.,CUPERTINO,CA 95014
DESIGNER:AMS Design
(415) 254-1606
2275 S. BASCOM AVE, CAMPBELL,CA 95008
SUITE 1406
AZADEH@AMSDESIGNLLP.COM
STRUCTURAL:AMS Design
(415) 254 -2634
2275 S. BASCOM AVE, CAMPBELL,CA 95008
SUITE 1406
ARMIN@AMSDESIGNLLP.COM
T24 & ENERGY:- - -
- - -
- - -
- - -
SOIL ENGINEER:- - -
- - -
- - -
- - -
VICINITY MAP:
375-36-014
NEW CONSTRUCTION
10592 JOHANSEN DR.,
CUPERTINO,CA 95014
R - 1-5
R - 3 / U
V - B
TWO (2) STORY
SPRINKLERED
LOW DENSITY(1-6 DU/Ac.)
CALIFORNIA RESIDENTIAL
CALIFORNIA BUILDING
CALIFORNIA MECHANICAL
CALIFORNIA PLUMBING
CALIFORNIA ELECTRICAL
CALIFORNIA ENERGY:
CALIFORNIA FIRE:
CALIFORNIA GREEN BUILDING:
ANY OTHER APPLICABLE LOCAL AND STATE LAWS
AND REGULATIONS.
A.
B.
C.
D.
E.
F.
G.
H.
I.
ASSESSOR'S PARCEL NUMBER:
PROJECT TYPE:
PROJECT LOCATION:
ZONING:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
NUMBER OF FLOORS:
FIRE PROTECTION:
LAND USE:
2016 EDITION
2016 EDITION
2016 EDITION
2016 EDITION
2016 EDITION
2016 EDITION
2016 EDITION
2016 EDITION
TOTAL "E" BUILDING TO BE REMOVED:2789 SQF
"N" 1ST FLOOR LIVING AREA:1349 SQF
"N" 2nd FLOOR LIVING AREA:848 SQF
"N" TOTAL LIVING:2197 SQF
"N" GARAGE:438 SQF
"N" TOTAL BUILDING:2635 SQF
"N" REAR PORCH:270 SQF
LOT AREA:5857 SQF PROPERTY LOCATION / NTS2ND FLOOR TO 1ST FLOOR RATIO=(848/(1349+438))X100=47.5%
NEW 2 STORY CUSTOME HOME
2635 SQ BUILDING AREA INCLUDING 4 BEDS, 3.5 BATH, 1 LAUNDRY AND 2 CAR
GARAGE
AREA CALCULATION:
PROJECT DATA:
"N" FLOOR AREA RATIO (FAR) = (2635/5857)X100=44.9%
DRAWING INDEX:
CODE EDITIONS:
SCOPE OF WORK:
PROJECT CONTACT:
FDN.Foundation
FLR.Floor
FURN.Furnace
G.C.General Contractor
G.F.C.I.Ground Fault Circuit Interrupt
GYP.Gypsum
H.B.Hose bib
HGT.Height
HR.Hour
H.R.Handrail
HTR.Heater
H.V.A.C.Heating, Venting and Air Conditioning
INSUL.Insulation
INT.Interior
LAM.Laminate
LAV.Lavatory
MAX.Maximum
MED.Medium
MIN.Minimum
MTL.Metal (steel)
MUL.Mullion
N.T.S.Not to scale
N.F.C.Not for construction
O.C.On center
O.H.Overhead
OPNG.Opening
GENERAL NOTES:
TREE INVENTORY:
A- AN AUTOMATIC RESIDENTIAL FIRE SPRINKLERS SYSTEM SHALL BE
INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS AS FOLLOWS: IN ALL NEW
ONE- AND TWO-FAMILY DWELLINGS AND IN EXISTING ONE- AND TWO-FAMILY
DWELLINGS WHEN ADDITIONS ARE MADE THAT INCREASE THE BUILDING AREA
TO MORE THAN 3,600 SQUARE FEET PER SEC R313.2.1. EXCEPTION: A ONE-
TIME ADDITION TO AN EXISTING BUILDING THAT DOES NOT TOTAL MORE THAN
1,000 SQUARE FEET OF BUILDING AREA. NOTE: THE OWNER(S), OCCUPANT(S)
AND ANY CONTRACTOR(S) OR SUBCONTRACTOR(S) ARE RESPONSIBLE FOR
CONSULTING WITH THE WATER PURVEYOR OF RECORD IN ORDER TO
DETERMINE IF ANY MODIFICATION OR UPGRADE OF THE EXISTING WATER
SERVICE IS REQUIRED. NOTE: COVERED PORCHES, PATIOS, BALCONIES, AND
ATTIC SPACES MAY REQUIRE FIRE SPRINKLER COVERAGE. A STATE OF
CALIFORNIA LICENSED (C-16) FIRE PROTECTION CONTRACTOR SHALL SUBMIT
PLANS, CALCULATIONS, A COMPLETED PERMIT APPLICATION AND
APPROPRIATE FEES TO THIS DEPARTMENT FOR REVIEW AND APPROVAL
PRIOR TO BEGINNING THEIR WORK. SECTION R313.2 AS ADOPTED BY CUPMC.
B- POTABLE WATER SUPPLIES SHALL BE PROTECTED FROM CONTAMINATION
CAUSED BY FIRE PROTECTION WATER SUPPLIES. IT IS THE RESPONSIBILITY OF
THE APPLICANT AND ANY CONTRACTORS AND SUBCONTRACTORS TO
CONTACT THE WATER PURVEYOR SUPPLYING THE SITE OF SUCH PROJECT,
AND TO COMPLY WITH THE REQUIREMENTS OF THAT PURVEYOR. SUCH
REQUIREMENTS SHALL BE INCORPORATED INTO THE DESIGN OF ANY WATER-
BASED FIRE PROTECTION SYSTEMS, AND/ OR FIRE SUPPRESSION WATER
SUPPLY SYSTEMS OR STORAGE CONTAINERS THAT MAY BE PHYSICALLY
CONNECTED IN ANY MANNER TO AN APPLIANCE CAPABLE OF CAUSING
CONTAMINATION OF THE POTABLE WATER SUPPLY OF THE PURVEYOR OF
RECORD. FINAL APPROVAL OF THE REQUIREMENTS OF THE WATER
PURVEYOR OF RECORD ARE DOCUMENTED BY THAT PURVEYOR AS HAVING
BEEN MET BY THE APPLICANT(S). 2010 CFC SEC. 903.3.5 AND HEALTH AND
SAFETY CODE 13114.7.
C- APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED OMN ALL NEW
AND EXISTING BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND
LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. PER CFC
SEC. 505
D- ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS
OF CFC CHAPTER 14 AND SANTA CLARA COUNTY'S FIRE DEPARTMENT'S
STANDARD DETAIL AND SPECIFICATION SI-7.
E- PHOTOELECTRIC SMOKE DETECTORS SHALL BE PROVIDED AT BOTH THE
TOP AND BOTTOM OF THE STAIRCASE.
F- PHOTOELECTRIC SMOKE ALARMS SHALL BE PROVIDED IN AREAS LEADING
TO SLEEPING ROOMS AND ON EVERY LEVEL. SMOKE ALARMS WITHIN
SLEEPING ROOMS SHALL BE DUAL SENSOR PHOTOELECTRIC/IONIZATION.
G- SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE
INTERCONNECTED PER RESIDENTIAL CODE.
H- A NFPA 13-D FIRE SPRINKLER SYSTEM SHALL BE INSTALLED UNDER
SEPERATE PERMIT.
I- A SEPARATE PERMIT FOR THE SPRINKLER SYSTEM SHALL BE APPLIED FOR
WITH THE SUNNYVALE BUREAU OF FIRE PREVENTION.
FIRE NOTES:
PLT.Plate
P.L.Property line
PLYWD.Plywood
PWR.Power
R.O.Rough Opening
R.O.W.Right of way
REFG.Refrigerator
REF.Reference
REV.Revision
RMV.Remove
S.C.Self-Closing
SCHED.Schedule
S.D.Smoke detector
SECT.Section
SHT.Sheet
T.O.C.Top of curb
T.O.F.Top of footing
TH.Threshold
TYP.Typical
UNF.Unfinished
W.C.Toilet (water closet)
WCT.Wainscot
W.H.Water Heater
W.I.Wrought Iron
W.I.C.Walk In Closet
YD.Yard
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
A- APPROVAL OF THESE PLANS DOES NOT RELEASE THE OWNER
AND/OR CONTRACTOR OF THE RESPONSIBILITY FOR THE
CORRECTIONS OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED
THEREIN. IF DURING THE COURSE OF CONSTRUCTION
IMPROVEMENTS, PUBLIC INTEREST REQUIRES A MODIFICATION OF/
OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION
OR THESE IMPROVEMENT PLANS ,THE CITY ENGINEER SHALL HAVE
THE AUTHORITY TO REQUIRE SUCH COMPLETED , AT THE SOLE
EXPENSE OF THE OWNER AND/OR CONTRACTOR.
B- CONTACT PUBLIC WORKS,(408)777-3104 , FOR INSPECTION OF
GRADING,STORM DRAINAGE, AND PUBLIC IMPROVEMENTS.
C- ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO
OCCUPANCY.
D- CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND
ENSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN
CONDITION.
E- CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE
PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING
ANY TREES.
F- UTILIZE BEST MANAGEMENT PRACTICES (BMP's) AS REQUIRED
BY THE STATE WATER RESOURCES CONTROL BOARD, FOR ANY
ACTIVITY, WHICH DISTURBS THE SOIL.
G- A WORK SCHEDULE OF GRADING AND ORISON & SEDIMENT
CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY
AUGUST 15. NO HILLSIDE GRADING SHALL BE PERFORMED
BETWEEN OCTOBER 1 TO APRIL 15.
H- ALL NEW ELECTRICAL SERVICE (POWER,PHONE,AND/OR CABLE)
SHALL BE UNDERGROUNDED.
I- TO INITIATE RELEASE OF BONDS,CONTACT THE PUBLIC WORKS
INSPECTOR FOR FINAL INSPECTION.
J- A LICENSED LAND SURVEYOR OR AUTHORIZED CIVIL ENGINEER
WILL PREPARE AND SUBMIT,TO THE PUBLIC WORKS DEPT,AN
ELEVATION CERTIFICATE FOR THE NEW STRUCTURE/ADDITION.
K- TO INITIAL RELEASE OF BONDS, CONTACT THE PUBLIC WORKED
INSPECTOR FOR FINAL INSPECTION.
L- ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE,
DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO
LANDSCAPED AREAS.
M- PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF
WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN
ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT.
PUBLIC WORKS NOTES:
A- THE PROPERTY OWNER SHALL RECORD A COVENANT ON THE
PROPERTY FOR THE NEW TREES/SHRUBS PLANTED FOR PURPOSE
OF REQUIRED REPLACEMENT TREES, PRIVACY PROTECTION, AND
REQUIRED FRONT YARD TREE.
B- FOLLOWING COMPLETION OF CONSTRUCTION, AN AFFIDAVIT
FROM AN ISA-CERTIFIED ARBORIST SHALL BE PROVIDED
CONFIRMING THAT THE NEW TREES HAVE BEEN PLANTED
PROPERTY AND ACCORDING TO PLAN.
C- A PLANNING DIVISION INSPECTION IS REQUIRED TO VERIFY
EXTERIOR MATERIALS/FINISHES, TREES, LANDSCAPING, AND SITE
WORK.
D- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL CONDUCT A
LANDSCAPE INSTALLATION AUDIT AFTER THE LANDSCAPING AND
IRRIGATION SYSTEM HAVE BEEN INSTALLED PER CHAPTER
14.15(LANDSCAPE ORDINANCE).THE FINDINGS OF THE
ASSESSMENT SHALL BE CONSOLIDATED INTO A LANDSCAPE
INSTALLATION REPORT PROVIDED TO THE PLANNING DIVISION.
E- THE PROPERTY OWNER SHALL SIGN A LANDSCAPE MAINTANCE
AGREEMENT PER CHAPTER 14.15(LANDSCAPE ORDINANCE),
PREPARED BY THE CITY,AND RECORD IT WITH SANTA CLARA CO.
RECORD'S OFFICE. THE PROPERTY OWNER SHALL CONTACT THE
PLANNING DIVISION IN ADVANCE OF THE FINAL TO PREPARE THE
AGREEMENT.
F- A CERTIFIED LANDSCAPE PROFESSIONAL SHALL PROVIDE A
LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE PER
CHAPTER 14.15(LANDSCAPE ORDINANCE) TO THE PLANNING
DIVISION.
REQ. PRIOR TO FINAL
OCCUPANCY:
Azadeh Masrour
Architectural Style:MEDITERRANEAN STYLE
1. Low pitched roof
2. Wide roof overhangs for sun shading, often with decorative brackets
3. Stucco or stone walls
4. Deep set windows and entries,with windows accentuated with surrounding trim
5. Distinctive chimney shapes and caps
6. Decorative columns and details
DESIGN PRINCIPLE:
"N"LOT COVERAGE: 1st FLOOR BLDG AREA (1349+438)SQF
COVERED AREA 270 SQF
1 BAY WINDOW 10 SQF
FIRST FLOOR ROOF EAVE 255
TOTAL %2322/5857 = 39.6%
FIRST FLOOR ROOF EAVE=170X1.5=255
SETBACK INFORMATION:
SETBACKS
Rear
Right
Left
EXIST.
1ST
PROPOSED
1ST/2ND
9'-6"/16'-6"
6'-7"/16'-6"
22'/35'-10"
Front 37'-7"/'40'-2"
5.1'
5.3'
32'
24.4'
"E" LOT COVERAGE: 1st FLOOR BLDG AREA 1520 SQF
FIRST FLOOR ROOF EAVE 220 SQF
TOTAL %1740/5857 = 24.3%(25%)
"E" FLOOR AREA RATIO (FAR) = (2789/5857)X100=47.6%
"E" BUILDING HEIGHT(ABOVE NATURAL GRADE): 26'
"N" BUILDING HEIGHT(ABOVE NATURAL GRADE): 26'- 11"'
SMA
PROPOSED SITE PLAN
SC : 1/8" = 1'-0"
1BLDG 1st FLOOR FOOTPRINT LINE
2nd FLOOR
PROPERTY LINE
BLDG 2nd FLOOR FOOTPRINT LINE
LEGEND:
1/8 INCH = 1 FEET
0 2 4 6 8 10 20 30
GRAPHIC SCALE :4:124:124:124:124:12
4:12
4:124:12w / Ww / Ww / WGAS
GASGASGASGASGASGASE / L
E / LE / LE / LE / LE / LSSSSSSSSSSSSS
SSSSSSSS5'-7"
18'-0"
16'-9"
15'-1"
16'-6"
16'-6"
7'-0"
5'-0"26'-8"27'-8"40'-2"41'-8"9'-6"
16'-6"
6'-7"17'-0"FRONT YARD:60'X20'= 1200 SQF
PAVING AREA:
DRIVE WAY/ WALKWAY(440)/1200=36.6%<50%
FRONT YARD PAVING SURFACE AREA:
STREET TREE TO BE INSTALLED BY THE CITY. UPON PROJECT COMPLETION, THE PROPERTY OWNER SHALL PREPARE AN
ADEQUATE PLANTING AREA AND CONTACT THE CITY AT 408-777-3269 TO ARRANGE FOR THE TREE INSTALLATION
JOHANSEN AVE.
CURB SIDE
DRIVE WAY
20' rear setback
5'side setback5'side setback20'front setback
59.00'
51.76'105.97'105'5' P.U.E.
"N" 6' HEIGHT WOODEN FENCE
"N" 6' HEIGHT WOODEN FENCE"N" 6' HEIGHT WOODEN FENCEFRONT YARD:1180 SQF
PAVING AREA:
DRIVE WAY/ WALKWAY(368+42)/1180=34.7%<40%
FRONT YARD PAVING SURFACE AREA:
GAS METER
ELEC. METER
WATER METER
AC
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
SITE PLAN
1/8" = 1'
A-01.01
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
NORTH
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
1. CONTACT PUBLIC WORKS, FOR DRAINAGE AND FINAL GRADE INSPECTION,
WHICH INCLUDES DRAIN LINES AND ROOF DRAINS/DOWN SPOUTS.
2. ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY.
3. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING THE AREA
ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION.
4. THE CONTRACTOR SHALL REVIEW STD. DETAIL 6-4 ON TREE PROTECTION
PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES.
5. UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE
WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS
SOIL.
6. ALL NEW ELECTRICAL SERVICE (POWER, PHONE, AND OR CABLE) SHALL BE
UNDER GROUND.
7. TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR
FOR FINAL INSPECTION.
8. ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED
AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPE AREAS.
9. PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE
CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT
FROM THE PUBLIC WORKS DEPARTMENT.
10. PROVIDE MIN. 5% GRADE SLOPE AWAY FROM FOUNDATION FOR A MIN.
DISTANCE OF 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE WALL.
WITH EXCEPTION:
a. IF BUILDING SITE DOES NOT ALLOW 10 FEET OF SLOPE, INDICATE THE
INSTALLATION OF DRAINS OR SWALES TO ENSURE DRAINAGE AWAY FROM THE
STRUCTURE.
b. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION
SHALL BE SLOPED A MIN 2% AWAY FROM THE BUILDING.
11. (E) DRAINAGE SHALL REMAIN THROUGHOUT CONSTRUCTION.
GRADING and DEMO NOTES:
1. A PLOT PLAN SHALL BE PREPARED DESCRIBING THE RELATIONSHIP OF
PROPOSED GRADING AND UTILITY TRENCHING TO THE TREES DESIGNATED FOR
PRESERVATION. CONSTRUCTION AND GRADING SHOULD NOT SIGNIFICANTLY
RAISE OR LOWER THE GROUND LEVEL BENEATH TREE DRIP LINES. IF THE
GROUND LEVEL IS PROPOSED FOR MODIFICATION BENEATH THE DRIP LINE, THE
ARCHITECT/ARBORIST SHALL ADDRESS AND MITIGATE THE IMPACT TO THE
TREE(S).
2. ALL TREES TO BE PRESERVED ON THE PROPERTY AND ALL TREES ADJACENT
TO THE PROPERTY SHALL BE PROTECTED AGAINST DAMAGE DURING
CONSTRUCTION OPERATIONS BY CONSTRUCTING A FOUR-FOOT-HIGH FENCE
AROUND THE DRIP LINE, AND ARMOR AS NEEDED. THE EXTENT OF FENCING
AND ARMORING SHALL BE DETERMINED BY THE LANDSCAPE ARCHITECT. THE
TREE PROTECTION SHALL BE PLACED BEFORE ANY EXCAVATION OR GRADING
IS BEGUN AND SHALL BE MAINTAINED IN REPAIR FOR THE DURATION OF THE
CONSTRUCTION WORK.
3. NO CONSTRUCTION OPERATIONS SHALL BE CARRIED ON WITHIN THE DRIP
LINE AREA OF ANY TREE DESIGNATED TO BE SAVED EXCEPT AS IS AUTHORIZED
BY THE DIRECTOR OF COMMUNITY DEVELOPMENT.
4. IF THE TRENCHING IS REQUIRED TO PENETRATE THE PROTECTION BARRIER
FOR THE TREE, THE SECTION OF TRENCH IN THE DRIP LINE SHALL BE HAND DUG
SO AS TO PRECLUDE THE CUTTING OF ROOTS. PRIOR TO INITIATING ANY
TRENCHING WITHIN THE BARRIER APPROVAL BY STAFF WITH CONSULTATION OF
AN ARBORIST SHALL BE COMPLETED.
5. TREES WHICH REQUIRE ANY DEGREE OF FILL AROUND THE NATURAL GRADE
SHALL BE GUARDED BY RECOGNIZED STANDARDS OF TREE PROTECTION AND
DESIGN OF TREE WELLS.
6. THE AREA UNDER THE DRIP LINE OF THE TREE SHALL BE KEPT CLEAN. NO
CONSTRUCTION MATERIALS NOR CHEMICAL SOLVENTS SHALL BE STORED OR
DUMPED UNDER A TREE.
7. FIRES FOR ANY REASON SHALL NOT BE MADE WITHIN FIFTY FEET OF ANY
TREE SELECTED TO REMAIN AND SHALL BE LIMITED IN SIZE AND KEPT UNDER
CONSTANT SURVEILLANCE.
8. THE GENERAL CONTRACTOR SHALL USE A TREE SERVICE LICENSEE, AS
DEFINED BY CALIFORNIA BUSINESS AND PROFESSIONAL CODE, TO PRUNE AND
CUT OFF THE BRANCHES THAT MUST BE REMOVED DURING THE LANDSCAPE
ARCHITECT/ARBORIST WITH APPROVAL OF STAFF.
9. ANY DAMAGE TO EXISTING TREE CROWNS OR ROOT SYSTEMS SHALL BE
REPAIRED IMMEDIATELY BY AN APPROVED TREE SURGEON.
10. NO STORAGE OF CONSTRUCTION MATERIALS OR PARKING SHALL BE
PERMITTED WITHIN THE DRIP LINE AREA OF ANY TREE DESIGNATED TO BE
SAVED.
11. TREE PROTECTION REGULATIONS SHALL BE POSTED ON PROTECTIVE
FENCING AROUND TREES TO BE PROTECTED.
TREE PROTECTION NOTES:
1. DIRECT ROOF RUNOFF ONTO VEGETATED AREAS.
2. DIRECT RUNOFF FROM SIDEWALK,WALKWAYS,AND/OR PATIOS ONTO
VEGETATED AREAS.
3. CONSTRUCT DRIVEWAY WITH PERMEABLE SURFACE.
GREEN BUILDING MEASURE NOTES:
Azadeh Masrour
AC unit will not be approved with this entitlement. AC
units will be reviewed at the building permit stage and
will need to meet the noise requirements which shall
not exceed 50 dbA. At the proposed 6’ setback, the
unit will need to emit less than 61 dbA.
SMA
1
SC : 1/4" = 1'-0"
PROPOSED 1ST FLOOR PLAN
PROPOSED 2ND FLOOR PLAN
SC : 1/4" = 1'-0"
2
1/4 INCH = 1 FEET
0 1 2 3 4 5 10 15
GRAPHIC SCALE :
UP
D/W
REF.16089
6080
6016
105010505050 288028805046 10080
6680
2880
60802650265060502630263020302480
308024806050
3880A-03-01
A
A-03-01
A A-03-01BA-03-01B3'-7"2'-0"2'-9"0'-10"2'-6"5'-0"2'-6"0'-10"3'-6"14'-9"26'-6"8'-0"3'-6"12'-0"12'-0"15'-10"12'-4"10'-0"4'-3"7'-9"
2'-5"8'-8"1'-7"
1'-1"
6'-0"
1'-0"
2'-11"16'-0"1'-9"
12'-8"8'-1"20'-8"
41'-5"
2'-10"2'-4"3'-1"6'-0"3'-2"2'-6"10'-0"5'-11"5'-0"3'-5"
12'-3"26'-10"
39'-1"
5'-2"4'-7"4'-0"1'-3"1'-3"3'-7"
4'-5"3'-0"2'-6"1'-9"1'-8"2'-0"3'-6"21'-2"20'-0"20'-0"
2'-5"8'-8"1'-7"
1'-1"
6'-0"
1'-0"
2'-11"16'-0"1'-9"
12'-8"8'-1"20'-8"
41'-5"
2'-10"17'-0"3'-0"2'-8"22'-8"4'-9"8'-4"11'-8"47'-5"2'-4"3'-1"6'-0"3'-2"2'-6"10'-0"5'-11"5'-0"3'-5"
12'-3"26'-10"
39'-1"
5'-2"19'-8"6'-0"2'-10"1'-2"2'-6"0'-10"5'-0"0'-11"2'-6"1'-5"28'-6"14'-4"42'-10"4'-7"
SKYLIGHTS SHALL BE TESTED AND
APPROVED, BEARING A LABEL INDICATING
COMPLIANCE WITH THE REQUIREMENTS
OF AAMA/WDMA/CSA 101/I.S.2/A440. [CRC
§R308.6.9] APN NO.: 375-36-014LOT GROSS AREA: 5,857%%P SF1 - PER SEC. 210.52 (C) OF THE 2016 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS, AT EACHCOUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULA SPACE 24" BY 12" ORLARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. COUNTER TOP SPACESSEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATESPACES. RECEPTACLE RENDERED INACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCESOCCUPYING DEPICTED SPACE SHALL NOT BE CONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2016 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET IS LESSTHAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2016 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TO SUPPLYGENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THE FOLLOWING MINIMUMREQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOP SURFACESSHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCH CIRCUIT.5 - PER SEC. 210.52 OF THE 2016 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOME SHALLBE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2016 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2016 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERE RECEPTACLESSERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6 FT OF THE EDGE OFTHE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION.8 - SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AND EACH STORY WITHIN DWELLING UNIT,INCLUDING BASEMENT BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS AS REQUIRED,PER SEC. 314.3 OF THE 2016 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION.9 - FOR NEW CONSTRUCTION,SMOKE DETECTORS AND CARBON MONOXIDE ALARMS TO BE HARD WIREDAND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING ISSERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP THEDETECTOR SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW., PER SEC. 314.5 & 315.1.1,2 OF THE2016CBC.9A - APPROVED CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATESLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND EVERY LEVEL INCLUDINGBASEMENTS IN DWELLING UNITS THAT HAVE FUEL-FIRED APPLICATIONS OR ATTACHED GARAGE.9B - SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNERTHAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS. [CRC §R314.6 & 315.7] 10 - PER SEC. 410.8 OF 2016 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWING CLEARANCESTO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVE ANENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2016 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED IN INSULATEDCEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BE APPROVED FORINSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2016 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMP LOCATIONSSHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY. LUMINARIES SUBJECTTO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS." LUMINARIES NOT SUBJECT TOSHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WET LOCATIONS" OR "SUITED FOR DAMPLOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOLUNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCI PROTECTED. FIXTURES MAYBE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTED FOR USE IN DAMPED LOCATIONS ANDGFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICACY OFNOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR AND GFCIPROTECTED. 16 -ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A.[CENC §150.0(K)1A] 16A -LIGHTING REQUIRED TO COMPLY REFERENCE JOINT APPENDIX JA8 PER CENC TABLE 150.0-ASHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. [CENC §150.0(K)2K] 17 -IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE INEACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. [CENC §150.0(K)2J] 17A -WITH THE 2016 CENC, ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY; THEREFORE, THE50% REQUIREMENT IN THE KITCHEN IS NO LONGER APPLICABLE. [CENC §150.0(K)1A] 18- PERMANENTLY MOUNTED OUTDOOR LIGHTING SHALL BE HIGH EFFICACY IN ACCORDANCE WITHCENC TABLE 150.0-A AND MEET THE REQUIREMENTS PER CENC §150.0(K)3A. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BE REMOVED BYPG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATE ANYOF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOM ENTRYDOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETS SHALL BELISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP.OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS,BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.
1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.) SHALL BEA MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW, SKYLIGHT ORATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE ABACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALL BE REDUCED 2FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVESOF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH CMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLY WITH CMC701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITS VERTICALDIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUM DISTANCE OF 4INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANT METALINSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOW CONDENSATE DUE TOA CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDING OVERFLOW AND ASECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAIN PAN. CMC 309.2
1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BE ACCESSIBLY BYAN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THE APPLIANCE, AND NOTLESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TO THE FURNACE AND ITSCONTROLS. (CMC 304.4)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY. ( CMC 304.4.1)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOTLESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC 304.2 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALL BEPROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 304.4.3)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCH LOCATED ATTHE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 304.4.4)
1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE AND CEILINGGYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.
ELECTRICAL NOTES:
TITLE 24 ENERGY NOTES:
FURNACE INSTALLATION: (In The Attic)
MECHANICAL & PLUMBING NOTES:
- THE EXHAUST FANS IN BATHROOMS WILL BE ENERGY STAR COMPLIANT, TERMINATE OUTSIDE THE BUILDING, ANDWILL BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGEOF 50 PERCENT TO 80 PERCENT. [CGBSC §4.506.1] - THE EXHAUST FANS IN BATHROOMS SHALL BE A MINIMUM EXHAUST RATE OF 50 CUBIC FEET PER MINUTE . [CMCTABLE 403.7]
BUILDING NOTES:
1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALLHAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOROPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOTMORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.2
2- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THECOUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.1
3- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWERHEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THEHEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2
4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING ANDSELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.
5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESSTHAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLYTEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHESABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED,LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3, #5
7- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOORWHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OFEITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THEBOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKINGSURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVEDPLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #6
8- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIORDOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWERTHAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS ANDNOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLINGWITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2
10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLEDON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.(GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC.R302.6 AND TABLE R302.6ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL ISREQUIRED.
11- BATHROOMS & KITCHEN:11.1- 22" MIN SHOWER DOOR CLEARANCE.11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESSAT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1)11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS.(CALGREEN 4.303.1)11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILEAPPLICATION SURROUNDING THE BATH TUB WALLS .11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.(CALGREEN 4.303.1)11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 2 GPM AT 80 PSI.(CALGREEN 4.303.1)
FLOOR FINISHES:
FIRE PLACE NOTES:CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTEDGAS FIREPLACES.
FEATURES:64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT 100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GASSUPPLY FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY THE GAS FIRE PLACE MUST BE DIRECT VENT, PER CURRENT 2016 ENERGY CODEHEAVY-GAUGE PAN BURNER SYSTEM WORKS WITH 4" BY 7" PIPE LOT 233R1LOT 234R1LOT 232R1JOHANSEN DRIVELOT GROSS AREA: 5,857%%P SFLOT 231R1N87°39'53"W 163.88'L=132.36'R=150.00'Δ=50°33'29"L=280.89'R=890.00'Δ=18°04'59"N66°18'21"W 70.00'L=57.95' R=890.00'Δ=3°43'51"N61°23'53"W 105.00(R) R1N31°38'31"E 51.76' R1N57°28'02"W 105.97' R1L=59.00'R=860.00'Δ=3°55'51"R1N65°03'44"W 106.66'N31°38'31"E 28.49'N56°16'11"W 106.69'N38°55'36"E 28.41'WA.DR.
NO OBSTRUCTIONS ARE ALLOWED
WITHIN 20'X20' GARAGE
2 Treads/Depth=11"
2 Riser / Height 6"
Nosing=1"
12"
BELOW F.F.
18"
BELOW F.F.SLOPEA-03-01C5'-0" X 6'-8"
11'-7" X 10'-11"
12'-0" X 14'-0"
20'-0" X 20'-0"
26'-7" X 27'-9"
5'-0" X 8'-0"2'-4" X 4'-2"
7'-11" X 11'-10"
GARAGE
BATH
POWDER
CLOSET
BEDROOM
KITCHEN & FAMILY
LIVING
ENTRY
ELEC. METER
GAS METER
BUILT IN SEAT - 24" ABOVE F.F
DN
DN104010405040
2030203036302630263050502480248040802880248018804030 263026302030203050802880
5080 2880
5050 1'-1"2'-6"0'-8"2'-6"1'-0"0'-6"2'-0"5'-8"2'-0"0'-8"0'-10"3'-6"1'-1"3'-2"13'-2"14'-4"2'-11"1'-3"1'-3"3'-4"3'-6"1'-7"1'-5"
3'-1"5'-0"6'-0"
2'-6"
2'-6"
3'-9"5'-0"3'-9"3'-1"5'-0"3'-4"
12'-6"11'-5"
23'-11"0'-11"2'-6"6'-11"2'-6"0'-11"3'-5"13'-9"3'-6"5'-5"2'-9"10'-10"39'-8"0'-10"2'-0"5'-6"2'-0"0'-7"1'-6"10'-11"2'-8"7'-9"5'-1"11'-9"39'-8"1'-4"4'-0"1'-4"3'-11"8'-5"2'-0"
6'-8"14'-4"
23'-11"
2'-11"
TITLE 24 ENERGY NOTES:
1 - PER SEC. 210.52 (C) OF THE 2013 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS,AT EACH COUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULASPACE 24" BY 12" OR LARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THEWALL LINE IS MORE THAN 24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THATSPACE. COUNTER TOP SPACES SEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALLBE CONSIDERED AS SEPARATE SPACES. RECEPTACLE RENDERED INACCESSIBLE BYAPPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEPICTED SPACE SHALL NOT BECONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2013 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET ISLESS THAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2013 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TOSUPPLY GENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THEFOLLOWING MINIMUM REQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOPSURFACES SHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCHCIRCUIT.5 - PER SEC. 210.52 OF THE 2013 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOMESHALL BE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2013 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETSINSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS,LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2013 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERERECEPTACLES SERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI)PROTECTION.8 -SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AS REQUIRED, PER SEC. 310.9.1.4 OFTHE 2010 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. 9 -SMOKE DETECTORS TO BE HARD WIRED AND SHALL RECEIVE THEIR PRIMARY POWER FROMTHE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE ANDSHALL BE EQUIPPED WITH A BATTERY BACK-UP THE DETECTOR SHALL EMIT A SIGNAL WHEN THEBATTERIES ARE LOW., PER SEC. 310.9.1.3 OF THE 2010CBC.10 - PER SEC. 410.8 OF 2013 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWINGCLEARANCES TO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVEAN ENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2013 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED ININSULATED CEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BEAPPROVED FOR INSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2013 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMPLOCATIONS SHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY.LUMINARIES SUBJECT TO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS."LUMINARIES NOT SUBJECT TO SHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WETLOCATIONS" OR "SUITED FOR DAMP LOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOL UNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCIPROTECTED. FIXTURES MAY BE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTEDFOR USE IN DAMPED LOCATIONS AND GFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE ANEFFICACY OF NOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR ANDGFCI PROTECTED.16 -AT LEAST HALF OF THE INSTALLED WATTAGE OF LIGHT FIXTURES IN KITCHENS SHALL BE HIGHEFFICACY AND THOSE THAT ARE NOT MUST BE SWITCHED SEPARATELY. HIGH EFFICACY LIGHTFIXTURES MUST PROVIDE AT LEAST 40 LUMEN PER WATT. ALMOST ALL FLUORESCENT LAMPSEQUIPPED W/ELECTRONIC BALLAST QUALIFY, (VERIFY) INCANDESCENT LAMPS (INCLUDING ANYSCREW IN INCANDESCENT LAMPS) QUARTZ HALOGEN LAMPS OR LOW VOLTAGE LAMPS SUCH ASHALOGEN LAMPS DO NOT.17 -OTHER ROOMS SHALL HAVE LIGHT FIXTURES EITHER BE HIGH EFFICACY (FLUORESCENT) ORSHALL BE CONTROLLED BY AN OCCUPANT SENSOR OR DIMMER. CLOSETS THAT ARE LESS THAN70 SQF, ARE EXEMPT FROM THIS REQUIREMENT. AN APPROVED OCCUPANT SENSOR DOES NOT ALLOW THE LIGHT TOBE TURNED ON AUTOMATICALLY. AND DOES NOT HAVE AN OVERRIDE THAT ALLOWS IT TO REMAINON.18 - ALL OUTDOOR LIGHT FIXTURES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ONTHE SAME LOT SHALL BE HIGH EFFICACY LIGHT FIXTURES (FLUORESCENT) OR SHALL BECONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BEREMOVED BY PG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATEANY OF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOMENTRY DOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLEOUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP. OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,DENS, BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.
1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.)SHALL BE A MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW,SKYLIGHT OR ATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING ANDHAVE A BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALLBE REDUCED 2 FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROLVALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH UMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLYWITH CMC 701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITSVERTICAL DIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUMDISTANCE OF 4 INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANTMETAL INSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOWCONDENSATE DUE TO A CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDINGOVERFLOW AND A SECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAINPAN. CMC 309.2
1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BEACCESSIBLY BY AN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TOTHE FURNACE AND ITS CONTROLS. (CMC 904.11.1)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THECENTER LINE OF THE PASSAGEWAY. ( CMC 904.11.4)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORINGNOT LESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC904.11.3 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALLBE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 904.11.4)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCHLOCATED AT THE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 904.11.5)
1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE ANDCEILING GYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.
ELECTRICAL NOTES:
FURNACE INSTALLATION: (In The Attic)
MECHANICAL & PLUMBING NOTES:
7'-2" X 2'-4"
11'-11" X 10'-6"
5'-8" X 2'-4"
2'-0" X 2'-4"
11'-0" X 10'-6"
8'-0" X 5'-0"
11'-4" X 7'-0"
14'-0" X 13'-0"
6'-0" X 11'-1"
4'-8" X 3'-2"
6'-0" X 5'-0"
MASTER BDRM
STAIRWELL
MASTER BATH
CLOSET
CLOSET
BATH
BEDROOM
CLOSET
BEDROOM
CLOSET
CLOSET
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE 10-INCHES.
FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESS THAN 0.75-INCHES, BUT NOT
MORE THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLY TEMPERED,
LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.
GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHES ABOVE A
STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR
APPROVED PLASTIC. CBC 2406.3, #5
7- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOOR WHERE THE
NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF
THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF GLAZING IS LESS
THAN 60-INCHES ABOVE THE WALKING SURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY
GLASS OR APPROVED PLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #6
8- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIOR DOORS SHALL BE
PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWER
BUILDING NOTES:
BUILDING NOTES:
1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER 200 SQFT IN
FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE
EMERGENCY ESCAPE AND RESCUE OPENING. R310.1
a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2
b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3
c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOR OPENINGS SHALL
HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1
d.OPENING SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES MEASURED FROM THE FLOOR.
310.1
2- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THE COUNTER FRONTS
AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.1
3- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWER HEADS SHALL
BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THE HEIGHT NOT LESS THAN 72 INCHES(6
FT). CRC R307.2
4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING AND SELF CLOSING,
SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.
5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE 10-INCHES. FOR
ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESS THAN 0.75-INCHES, BUT NOT MORE
THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLY TEMPERED,
LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.
GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHES ABOVE A STANDING
SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED
PLASTIC. CBC 2406.3, #5
7- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST
EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN
A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES
ABOVE THE WALKING SURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED
PLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #6
8- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIOR DOORS SHALL BE
PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWER THAN THE DOOR'S THRESHOLD FOR
IN-SWINGING AND SLIDING GLASS DOORS AND NOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY
DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLING WITHOUT USE OF KEY,
SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2
10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLED ON THE GARAGE
SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE. (GARAGE MUST BE SEPARATED FROM
THE DWELLING AND ITS ATTIC AREA) CRC SEC. R302.6 AND TABLE R302.6
ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL IS REQUIRED.
11- BATHROOMS & KITCHEN:
11.1- 22" MIN SHOWER DOOR CLEARANCE.
11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.
CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.
11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1)
11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS. (CALGREEN 4.303.1)
11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILE APPLICATION
SURROUNDING THE BATH TUB WALLS .
11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1)
THAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS AND NOT MORE
THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLING WITHOUT USE OF
KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2
10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLED ON THE
GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.(GARAGE MUST BE
SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC. R302.6 AND TABLE R302.6
ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL IS REQUIRED.
11- BATHROOMS & KITCHEN:
11.1- 22" MIN SHOWER DOOR CLEARANCE.
11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.
CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.
11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI. (CALGREEN 4.303.1)
11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS. (CALGREEN
4.303.1)
1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER 200 SQFT IN
FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE
OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1
a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2
b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3
c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOR OPENINGS SHALL
HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1
d.OPENING SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES MEASURED FROM THE
FLOOR. 310.1
2- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THE COUNTER
FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.1
3- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWER HEADS
SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THE HEIGHT NOT LESS THAN 72
INCHES(6 FT). CRC R307.2
4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING AND SELF CLOSING,
SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILE
APPLICATION SURROUNDING THE BATH TUB WALLS .
11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.
(CALGREEN 4.303.1)
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
NORTH
PROPOSED
FLOOR
PLAN
A-01.02
1/4" = 1'
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS
FIREPLACES.
FEATURES:
64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT
100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GAS SUPPLY
FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY
TOP VENT 40-FT. VERTICALLY OR 20-FT. HORIZONTALLY
HEAVY-GAUGE PAN BURNER SYSTEM
WORKS WITH 4" BY 7" PIPE
FIRE PLACE NOTES:
FIRE PLACE NOTES:
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR
VENTED GAS FIREPLACES.
FEATURES:
64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT
100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS
OFF GAS SUPPLY
FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY
TOP VENT 40-FT. VERTICALLY OR 20-FT. HORIZONTALLY
HEAVY-GAUGE PAN BURNER SYSTEM
WORKS WITH 4" BY 7" PIPE
BUILDING NOTES:
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER
200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL
HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1
a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2
b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3
c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOR
OPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1
d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOT
MORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.2
2- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THE
COUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.1
3- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWER
HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THE
HEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2
4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING AND
SELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.
5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE
10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESS
THAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLY
TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.
GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHES
ABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED,
LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3, #5
7- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOOR
WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OF
EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE
BOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKING
SURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVED
PLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #6
8- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIOR
DOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWER
THAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS AND
NOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLING
WITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2
10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLED
ON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.
(GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC.
R302.6 AND TABLE R302.6
ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL IS
REQUIRED.
11- BATHROOMS & KITCHEN:
11.1- 22" MIN SHOWER DOOR CLEARANCE.
11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.
CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.
11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESS
AT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1)
11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS.
(CALGREEN 4.303.1)
11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILE
APPLICATION SURROUNDING THE BATH TUB WALLS .
11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.
(CALGREEN 4.303.1)
11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 2 GPM AT 80 PSI.
(CALGREEN 4.303.1)
FIRE PLACE NOTES:
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED
GAS FIREPLACES.
FEATURES:
64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT
100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GAS
SUPPLY
FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY
THE GAS FIRE PLACE MUST BE DIRECT VENT, PER CURRENT 2016 ENERGY CODE
HEAVY-GAUGE PAN BURNER SYSTEM
WORKS WITH 4" BY 7" PIPE
FLOOR FINISHES:
LEGEND:
NEW CONSTRUCTION WALL
Azadeh Masrour
SMA
1
PROPOSED REAR (EAST) ELEVATION
2
SC : 1/4" = 1'-0"
PROPOSED FRONT (WEST) ELEVATION
SC : 1/4" = 1'-0"
4
12
4
12
104010405040
4030
5046
10080
6050
104010405040
4030
5046
10080
6050
Electrical Meter
Gas MeterOutdoor Compressor Unit 10'-0"10'-0"1'-4"21'-4"9'-6"25°25°9'-6" FROM PROPERTY LINE
TO THE EXTERIOR WALL
D
AYLIG
HT LINE
10'-0" VERTICAL LINE FROMNATURAL GRADE ATBUILDING PROPERTY LINECLASS A TILE ROOFING.
INSTALLATION PER MANUFACTURE
RECOMMENDATION. VERIFY WITH OWNER
OR DESIGNER FOR COLOR.
(EXAMP.:EAGLE ROOF TILE WITH PRODUCT
NUMBER :4678 OR EQUAL)
5' FROM PROPERTY
LINE TO THE
EXTERIOR WALL
D A Y L IG H T L IN E
10'-0" VERTICAL LINE FROMNATURAL GRADE ATBUILDING PROPERTY LINE26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.
WIN. SILL 60" ABOVE F.F.
104010405040
4030
5046
10080
6050
104010405040
4030
5046
10080
6050
Electrical Meter
Gas MeterOutdoor Compressor Unit
4
12
50505050
16089
6080
6016
105010505050
50505050
16089
6080
105010505050 10'-0"10'-0"1'-5"21'-4"3'-0"3'-0"15'-3"25°25°5' FROM PROPERTY
LINE TO THE
EXTERIOR WALL
D
AYLIG
HT LINE
10'-0" VERTICAL LINE FROMNATURAL GRADE ATBUILDING PROPERTY LINECLASS A TILE ROOFING.
INSTALLATION PER MANUFACTURE
RECOMMENDATION. VERIFY WITH OWNER
OR DESIGNER FOR COLOR.
(EXAMP.:EAGLE ROOF TILE WITH PRODUCT
NUMBER :4678 OR EQUAL)
9'-6" FROM PROPERTY LINE
TO THE EXTERIOR WALL
D A Y L IG H T L IN E
10'-0" VERTICAL LINE FROMNATURAL GRADE ATBUILDING PROPERTY LINE26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.
WIN. SILL 36" ABOVE F.F.WIN. SILL 36" ABOVE F.F.
ABOVE
NATURAL GRADE
13' PLATE HT.
ENTRY
2650
50505050
16089
6080
6016
105010505050
50505050
16089
6080
105010505050
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
PROPOSED
ELEVATIONS
1/4" = 1'
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
A-02.01
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
"ANY CHANGES TO T HE APPROVED COLORS, MATERIALS, AND EXT ERIOR FINISHES SHALL BE REVIEWED
AND APPROVED BY THE CITY OF CUPERTINO PLANNING DIVISION PRIOR TO INSTALLATION/APPLICATION."
Azadeh Masrour
SMA
SC : 1/4" = 1'-0"
2
1
PROPOSED LEFT (NORTH) ELEVATION
SC : 1/4" = 1'-0"
PROPOSED RIGHT (SOUTH) ELEVATION
4
12
2030203020302030 263026302030
2030
263026302030
2030
3080
Electrical Meter
Outdoor Compressor Unit
2630263026302630 10'-0"10'-0"1'-4"21'-4"5'-0"5'-0"5'-0"CLASS A TILE ROOFING.
INSTALLATION PER MANUFACTURE
RECOMMENDATION. VERIFY WITH OWNER
OR DESIGNER FOR COLOR.
(EXAMP.:EAGLE ROOF TILE WITH PRODUCT
NUMBER :4678 OR EQUAL)
26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.
WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.
2030203020302030 263026302030
2030
263026302030
2030
3080
Electrical Meter
Outdoor Compressor Unit
2630263026302630
4
12
26302630 203036302630
6050
203036302630
6050
Gas Meter
20302030
26502650
20302030
26502650 10'-0"10'-0"1'-4"21'-4"5'-0"CLASS A TILE ROOFING.
INSTALLATION PER MANUFACTURE
RECOMMENDATION. VERIFY WITH OWNER
OR DESIGNER FOR COLOR.
(EXAMP.:EAGLE ROOF TILE WITH PRODUCT
NUMBER :4678 OR EQUAL)
26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.
WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.WIN. SILL 60" ABOVE F.F.
26302630 203036302630
6050
203036302630
6050
Gas Meter
20302030
26502650
20302030
26502650
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
PROPOSED
ELEVATIONS
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
1/4" = 1'
A-02.02
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
"ANY CHANGES TO T HE APPROVED COLORS, MATERIALS, AND EXT ERIOR FINISHES SHALL BE REVIEWED
AND APPROVED BY THE CITY OF CUPERTINO PLANNING DIVISION PRIOR TO INSTALLATION/APPLICATION."
Azadeh Masrour
SMA
SC : 1/4" = 1'-0"
3
STREETSCAPE ELEVATION
1
A - A CROSS SECTION
SC : 1/4" = 1'-0"
2
B - B CROSS SECTION
10600 JOHANSEN DR.
SC : 1/8" = 1'-0"
10584 JOHANSEN DR.
SC : 1/4" = 1'-0"
3
C - C CROSS SECTION
4
12
attic
NEW R-13 INSUL.-
TYP. ALL EXT. WALLS
NEW R-30 INSUL.-
TYP. ALL ROOF
NEW R-19
INSUL.-
TYP. ENT.
FLOOR 10'-0"10'-0"1'-4"21'-4"608
0
601
6
Water Meter
288
0
26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.
4
12
attic
NEW R-13 INSUL.-
TYP. ALL EXT. WALLS
NEW R-30 INSUL.-
TYP. ALL ROOF
NEW R-19
INSUL.-
TYP. ENT.
FLOOR 10'-0"10'-0"1'-4"21'-4"288
0
288
0
248
0
248
0
263
0
263
0
288
0
Water Meter
26'-11" TOP HT.
F.F.
NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
10' PLATE HT.
ABOVE F.F.
ABOVE
NATURAL GRADE
(2 Nd Floor)
ABOVE F.F.
21' PLATE HT.2'-0"NATURAL GRADE LINE
18" ABOVE NATURAL GRADE
F.F.
0950 09503450 2650 2650
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
SECTIONS
and
STREETSCAPE
ELEVATION
1/4" = 1'
A-03.01
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
Azadeh Masrour
SMA
UP
D/W
REF.20'-4"
12'-6"20'-3"26'-9"22'-7"20'-5"20'-5"
5'-1"2'-5"20'-5"9'-9"7'-0"
SKYLIGHTS SHALL BE TESTED AND
APPROVED, BEARING A LABEL INDICATING
COMPLIANCE WITH THE REQUIREMENTS
OF AAMA/WDMA/CSA 101/I.S.2/A440. [CRC
§R308.6.9]
1 - PER SEC. 210.52 (C) OF THE 2016 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS, AT EACHCOUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULA SPACE 24" BY 12" ORLARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. COUNTER TOP SPACESSEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATESPACES. RECEPTACLE RENDERED INACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCESOCCUPYING DEPICTED SPACE SHALL NOT BE CONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2016 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET IS LESSTHAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2016 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TO SUPPLYGENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THE FOLLOWING MINIMUMREQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOP SURFACESSHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCH CIRCUIT.5 - PER SEC. 210.52 OF THE 2016 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOME SHALLBE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2016 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2016 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERE RECEPTACLESSERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6 FT OF THE EDGE OFTHE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION.8 - SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AND EACH STORY WITHIN DWELLING UNIT,INCLUDING BASEMENT BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS AS REQUIRED,PER SEC. 314.3 OF THE 2016 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION.9 - FOR NEW CONSTRUCTION,SMOKE DETECTORS AND CARBON MONOXIDE ALARMS TO BE HARD WIREDAND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING ISSERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP THEDETECTOR SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW., PER SEC. 314.5 & 315.1.1,2 OF THE2016CBC.9A - APPROVED CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATESLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND EVERY LEVEL INCLUDINGBASEMENTS IN DWELLING UNITS THAT HAVE FUEL-FIRED APPLICATIONS OR ATTACHED GARAGE.9B - SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNERTHAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS. [CRC §R314.6 & 315.7] 10 - PER SEC. 410.8 OF 2016 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWING CLEARANCESTO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVE ANENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2016 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED IN INSULATEDCEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BE APPROVED FORINSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2016 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMP LOCATIONSSHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY. LUMINARIES SUBJECTTO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS." LUMINARIES NOT SUBJECT TOSHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WET LOCATIONS" OR "SUITED FOR DAMPLOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOLUNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCI PROTECTED. FIXTURES MAYBE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTED FOR USE IN DAMPED LOCATIONS ANDGFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICACY OFNOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR AND GFCIPROTECTED. 16 -ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A.[CENC §150.0(K)1A] 16A -LIGHTING REQUIRED TO COMPLY REFERENCE JOINT APPENDIX JA8 PER CENC TABLE 150.0-ASHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. [CENC §150.0(K)2K] 17 -IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE INEACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. [CENC §150.0(K)2J] 17A -WITH THE 2016 CENC, ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY; THEREFORE, THE50% REQUIREMENT IN THE KITCHEN IS NO LONGER APPLICABLE. [CENC §150.0(K)1A] 18- PERMANENTLY MOUNTED OUTDOOR LIGHTING SHALL BE HIGH EFFICACY IN ACCORDANCE WITHCENC TABLE 150.0-A AND MEET THE REQUIREMENTS PER CENC §150.0(K)3A. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BE REMOVED BYPG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATE ANYOF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOM ENTRYDOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETS SHALL BELISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP.OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS,BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.
1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.) SHALL BEA MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW, SKYLIGHT ORATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE ABACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALL BE REDUCED 2FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVESOF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH CMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLY WITH CMC701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITS VERTICALDIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUM DISTANCE OF 4INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANT METALINSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOW CONDENSATE DUE TOA CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDING OVERFLOW AND ASECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAIN PAN. CMC 309.2
1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BE ACCESSIBLY BYAN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THE APPLIANCE, AND NOTLESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TO THE FURNACE AND ITSCONTROLS. (CMC 304.4)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY. ( CMC 304.4.1)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOTLESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC 304.2 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALL BEPROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 304.4.3)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCH LOCATED ATTHE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 304.4.4)
1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE AND CEILINGGYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.
ELECTRICAL NOTES:
TITLE 24 ENERGY NOTES:
FURNACE INSTALLATION: (In The Attic)
MECHANICAL & PLUMBING NOTES:
- THE EXHAUST FANS IN BATHROOMS WILL BE ENERGY STAR COMPLIANT, TERMINATE OUTSIDE THE BUILDING, ANDWILL BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGEOF 50 PERCENT TO 80 PERCENT. [CGBSC §4.506.1] - THE EXHAUST FANS IN BATHROOMS SHALL BE A MINIMUM EXHAUST RATE OF 50 CUBIC FEET PER MINUTE . [CMCTABLE 403.7]
BUILDING NOTES:1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALLHAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOROPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOTMORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.22- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THECOUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.13- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWERHEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THEHEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2
4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING ANDSELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESSTHAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLYTEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHESABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED,LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3, #57- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOORWHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OFEITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THEBOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKINGSURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVEDPLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #68- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIORDOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWERTHAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS ANDNOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLINGWITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.2
10- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLEDON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.(GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC.R302.6 AND TABLE R302.6ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL ISREQUIRED.
11- BATHROOMS & KITCHEN:11.1- 22" MIN SHOWER DOOR CLEARANCE.11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESSAT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1)11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS.(CALGREEN 4.303.1)11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILEAPPLICATION SURROUNDING THE BATH TUB WALLS .11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.(CALGREEN 4.303.1)11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 2 GPM AT 80 PSI.(CALGREEN 4.303.1)
FLOOR FINISHES:
FIRE PLACE NOTES:CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTEDGAS FIREPLACES.FEATURES:64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT 100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GASSUPPLY FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY THE GAS FIRE PLACE MUST BE DIRECT VENT, PER CURRENT 2016 ENERGY CODEHEAVY-GAUGE PAN BURNER SYSTEM WORKS WITH 4" BY 7" PIPE
WA.DR.
G
E
F
H
I
JNO OBSTRUCTIONS ARE ALLOWED
WITHIN 20'X20' GARAGE
2 Treads/Depth=11"
2 Riser / Height 6"
Nosing=1"SLOPEA-03-01CDN
DN 16'-10"6'-11"13'-6"14'-4"23'-1"12'-9"21'-6"11'-4"
TITLE 24 ENERGY NOTES:
1 - PER SEC. 210.52 (C) OF THE 2013 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS,AT EACH COUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULASPACE 24" BY 12" OR LARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THEWALL LINE IS MORE THAN 24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THATSPACE. COUNTER TOP SPACES SEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALLBE CONSIDERED AS SEPARATE SPACES. RECEPTACLE RENDERED INACCESSIBLE BYAPPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEPICTED SPACE SHALL NOT BECONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2013 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET ISLESS THAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2013 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TOSUPPLY GENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THEFOLLOWING MINIMUM REQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOPSURFACES SHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCHCIRCUIT.5 - PER SEC. 210.52 OF THE 2013 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOMESHALL BE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2013 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETSINSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS,LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2013 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERERECEPTACLES SERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI)PROTECTION.8 -SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AS REQUIRED, PER SEC. 310.9.1.4 OFTHE 2010 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. 9 -SMOKE DETECTORS TO BE HARD WIRED AND SHALL RECEIVE THEIR PRIMARY POWER FROMTHE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE ANDSHALL BE EQUIPPED WITH A BATTERY BACK-UP THE DETECTOR SHALL EMIT A SIGNAL WHEN THEBATTERIES ARE LOW., PER SEC. 310.9.1.3 OF THE 2010CBC.10 - PER SEC. 410.8 OF 2013 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWINGCLEARANCES TO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVEAN ENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2013 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED ININSULATED CEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BEAPPROVED FOR INSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2013 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMPLOCATIONS SHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY.LUMINARIES SUBJECT TO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS."LUMINARIES NOT SUBJECT TO SHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WETLOCATIONS" OR "SUITED FOR DAMP LOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOL UNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCIPROTECTED. FIXTURES MAY BE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTEDFOR USE IN DAMPED LOCATIONS AND GFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE ANEFFICACY OF NOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR ANDGFCI PROTECTED.16 -AT LEAST HALF OF THE INSTALLED WATTAGE OF LIGHT FIXTURES IN KITCHENS SHALL BE HIGHEFFICACY AND THOSE THAT ARE NOT MUST BE SWITCHED SEPARATELY. HIGH EFFICACY LIGHTFIXTURES MUST PROVIDE AT LEAST 40 LUMEN PER WATT. ALMOST ALL FLUORESCENT LAMPSEQUIPPED W/ELECTRONIC BALLAST QUALIFY, (VERIFY) INCANDESCENT LAMPS (INCLUDING ANYSCREW IN INCANDESCENT LAMPS) QUARTZ HALOGEN LAMPS OR LOW VOLTAGE LAMPS SUCH ASHALOGEN LAMPS DO NOT.17 -OTHER ROOMS SHALL HAVE LIGHT FIXTURES EITHER BE HIGH EFFICACY (FLUORESCENT) ORSHALL BE CONTROLLED BY AN OCCUPANT SENSOR OR DIMMER. CLOSETS THAT ARE LESS THAN70 SQF, ARE EXEMPT FROM THIS REQUIREMENT. AN APPROVED OCCUPANT SENSOR DOES NOT ALLOW THE LIGHT TOBE TURNED ON AUTOMATICALLY. AND DOES NOT HAVE AN OVERRIDE THAT ALLOWS IT TO REMAINON.18 - ALL OUTDOOR LIGHT FIXTURES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ONTHE SAME LOT SHALL BE HIGH EFFICACY LIGHT FIXTURES (FLUORESCENT) OR SHALL BECONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BEREMOVED BY PG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATEANY OF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOMENTRY DOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLEOUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP. OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,DENS, BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.
1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.)SHALL BE A MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW,SKYLIGHT OR ATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING ANDHAVE A BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALLBE REDUCED 2 FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROLVALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH UMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLYWITH CMC 701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITSVERTICAL DIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUMDISTANCE OF 4 INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANTMETAL INSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOWCONDENSATE DUE TO A CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDINGOVERFLOW AND A SECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAINPAN. CMC 309.2
1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BEACCESSIBLY BY AN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TOTHE FURNACE AND ITS CONTROLS. (CMC 904.11.1)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THECENTER LINE OF THE PASSAGEWAY. ( CMC 904.11.4)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORINGNOT LESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC904.11.3 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALLBE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 904.11.4)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCHLOCATED AT THE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 904.11.5)
1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE ANDCEILING GYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.
ELECTRICAL NOTES:
FURNACE INSTALLATION: (In The Attic)
MECHANICAL & PLUMBING NOTES:
A
B
CD
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
DECORAMOULD
Feather River Doors
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
TYPE
SQR. EDGE - 4" HT. X 2" DPT.
DRAWN BY :CLOPA Y
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
WHITE COLOR
REMODELING FOR:
BY
OWNERSHIP:
EXTERI O R M A TERI A L SCHED ULE
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
ROOF
EXTERI OR TRIM
1/8" = 1'
A-06.01
DIAGRAMS and
SCHEDULES
DOOR BROWN COLOR
MI LGARDWINDOWS
STUCCO
1349
TI LE ROOFI NG
TITLE
SMOOTH
TUSCANY / WHITE
SI DI NG
E
TOTAL BUILDING AREA 2635
GA RAGE DOOR
FLOORS SIZE
14'-4" X 13'-6"
AREAS (SQF)TOTAL
16'-10" X 6'-11"B
A
116
C 11'-4" X21'-6"244
D 23'-1" X 12'-9"294
I 5'-1" X 2'-5"12
J 20'-5" X 20'-5"
194
426
SPACES
848
INFO
2ND FLOOR
438GARAGE
F
G
H
22'-7" X 26'-9"605
20'-4" X 20'-5"424
12'-6" X 20'-3"252
7'-0" X 9'-9"68
1ST
FLOOR
FLOOR AREA DIAGRAM(PROPOSED PLAN):
SCALE: 1/8" : 1'
STUCCO TI LE ROOFI NG
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
Azadeh Masrour
SMA
1
SC : 1/4" = 1'-0"
EXISTING 1ST FLOOR PLAN EXISTING 2ND FLOOR PLAN
SC : 1/4" = 1'-0"
2D/WREF.3080505016080
60803080
5050
3080
6080
3080465050332480
2680
2580
6080
5050
5050288024802580
UP
0'-8"
3'-0"4'-1"6'-0"3'-0"1'-11"16'-0"2'-9"
5'-4"16'-9"20'-8"
42'-9"
3'-0"6'-0"1'-1"3'-0"1'-2"5'-0"0'-7"3'-2"5'-0"3'-0"0'-5"6'-0"5'-4"
19'-10"11'-2"11'-9"
42'-9"6'-10"5'-0"5'-3"3'-0"0'-5"20'-6"15'-6"46'-9"2'-6"5'-0"3'-3"10'-9"2'-0"5'-0"2'-4"1'-2"4'-6"0'-9"3'-0"3'-1"11'-2"5'-4"9'-4"12'-6"8'-5"46'-9" SKYLIGHTS SHALL BE TESTED ANDAPPROVED, BEARING A LABEL INDICATINGCOMPLIANCE WITH THE REQUIREMENTSOF AAMA/WDMA/CSA 101/I.S.2/A440. [CRC§R308.6.9] APN NO.: 375-36-014LOT GROSS AREA: 5,857%%P SF1 - PER SEC. 210.52 (C) OF THE 2016 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS, AT EACHCOUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULA SPACE 24" BY 12" ORLARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. COUNTER TOP SPACESSEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATESPACES. RECEPTACLE RENDERED INACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCESOCCUPYING DEPICTED SPACE SHALL NOT BE CONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2016 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET IS LESSTHAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2016 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TO SUPPLYGENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THE FOLLOWING MINIMUMREQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOP SURFACESSHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCH CIRCUIT.5 - PER SEC. 210.52 OF THE 2016 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOME SHALLBE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2016 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2016 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERE RECEPTACLESSERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6 FT OF THE EDGE OFTHE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION.8 - SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AND EACH STORY WITHIN DWELLING UNIT,INCLUDING BASEMENT BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS AS REQUIRED,PER SEC. 314.3 OF THE 2016 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION.9 - FOR NEW CONSTRUCTION,SMOKE DETECTORS AND CARBON MONOXIDE ALARMS TO BE HARD WIREDAND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING ISSERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP THEDETECTOR SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW., PER SEC. 314.5 & 315.1.1,2 OF THE2016CBC.9A - APPROVED CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATESLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND EVERY LEVEL INCLUDINGBASEMENTS IN DWELLING UNITS THAT HAVE FUEL-FIRED APPLICATIONS OR ATTACHED GARAGE.9B - SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNERTHAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS. [CRC §R314.6 & 315.7] 10 - PER SEC. 410.8 OF 2016 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWING CLEARANCESTO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVE ANENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2016 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED IN INSULATEDCEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BE APPROVED FORINSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2016 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMP LOCATIONSSHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY. LUMINARIES SUBJECTTO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS." LUMINARIES NOT SUBJECT TOSHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WET LOCATIONS" OR "SUITED FOR DAMPLOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOLUNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCI PROTECTED. FIXTURES MAYBE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTED FOR USE IN DAMPED LOCATIONS ANDGFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICACY OFNOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR AND GFCIPROTECTED. 16 -ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A.[CENC §150.0(K)1A] 16A -LIGHTING REQUIRED TO COMPLY REFERENCE JOINT APPENDIX JA8 PER CENC TABLE 150.0-ASHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. [CENC §150.0(K)2K] 17 -IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE INEACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. [CENC §150.0(K)2J] 17A -WITH THE 2016 CENC, ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY; THEREFORE, THE50% REQUIREMENT IN THE KITCHEN IS NO LONGER APPLICABLE. [CENC §150.0(K)1A] 18- PERMANENTLY MOUNTED OUTDOOR LIGHTING SHALL BE HIGH EFFICACY IN ACCORDANCE WITHCENC TABLE 150.0-A AND MEET THE REQUIREMENTS PER CENC §150.0(K)3A. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BE REMOVED BYPG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATE ANYOF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOM ENTRYDOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETS SHALL BELISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP.OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS,BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.) SHALL BEA MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW, SKYLIGHT ORATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE ABACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALL BE REDUCED 2FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVESOF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH CMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLY WITH CMC701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITS VERTICALDIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUM DISTANCE OF 4INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANT METALINSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOW CONDENSATE DUE TOA CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDING OVERFLOW AND ASECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAIN PAN. CMC 309.2 1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BE ACCESSIBLY BYAN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THE APPLIANCE, AND NOTLESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TO THE FURNACE AND ITSCONTROLS. (CMC 304.4)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY. ( CMC 304.4.1)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOTLESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC 304.2 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALL BEPROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 304.4.3)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCH LOCATED ATTHE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 304.4.4)1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE AND CEILINGGYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.ELECTRICAL NOTES:TITLE 24 ENERGY NOTES:FURNACE INSTALLATION: (In The Attic)MECHANICAL & PLUMBING NOTES:- THE EXHAUST FANS IN BATHROOMS WILL BE ENERGY STAR COMPLIANT, TERMINATE OUTSIDE THE BUILDING, ANDWILL BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGEOF 50 PERCENT TO 80 PERCENT. [CGBSC §4.506.1] - THE EXHAUST FANS IN BATHROOMS SHALL BE A MINIMUM EXHAUST RATE OF 50 CUBIC FEET PER MINUTE . [CMCTABLE 403.7] BUILDING NOTES:1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALLHAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOROPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOTMORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.22- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THECOUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.13- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWERHEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THEHEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2 4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING ANDSELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESSTHAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED.6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLYTEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHESABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED,LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3, #57- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOORWHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OFEITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THEBOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKINGSURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVEDPLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #68- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIORDOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWERTHAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS ANDNOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLINGWITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.210- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLEDON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.(GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC.R302.6 AND TABLE R302.6ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL ISREQUIRED. 11- BATHROOMS & KITCHEN:11.1- 22" MIN SHOWER DOOR CLEARANCE.11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESSAT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1)11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS.(CALGREEN 4.303.1)11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILEAPPLICATION SURROUNDING THE BATH TUB WALLS .11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.(CALGREEN 4.303.1)11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 2 GPM AT 80 PSI.(CALGREEN 4.303.1)FLOOR FINISHES:FIRE PLACE NOTES:CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTEDGAS FIREPLACES.FEATURES:64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT 100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GASSUPPLY FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY THE GAS FIRE PLACE MUST BE DIRECT VENT, PER CURRENT 2016 ENERGY CODEHEAVY-GAUGE PAN BURNER SYSTEM WORKS WITH 4" BY 7" PIPE LOT 233R1LOT 234R1LOT 232R1JOHANSEN DRIVELOT GROSS AREA: 5,857%%P SFLOT 231R1N87°39'53"W 163.88'L=132.36'R=150.00'Δ=50°33'29"L=280.89'R=890.00'Δ=18°04'59"N66°18'21"W 70.00'L=57.95' R=890.00'Δ=3°43'51"N61°23'53"W 105.00(R) R1N31°38'31"E 51.76' R1N57°28'02"W 105.97' R1L=59.00'R=860.00'Δ=3°55'51"R1N65°03'44"W 106.66'N31°38'31"E 28.49'N56°16'11"W 106.69'N38°55'36"E 28.41'20'-0" X 20'-1"21'-9" X 20'-7"
30'-4" X 14'-10"
11'-9" X 8'-11"
10'-6" X 10'-10"
LIVING GARAGE
DINING
KITCHEN
FAMILY
DN
DN
2020 5050 5050
3020505050503050505028802880288024805080508028802880
6'-1"5'-0"
0'-7"
3'-0"4'-2"5'-10"5'-0"
0'-3"
5'-4"11'-1"2'-4"10'-0"2'-4"11'-8"
42'-9"11'-0"3'-9"0'-7"5'-0"7'-9"0'-11"3'-0"18'-9"13'-4"22'-8"36'-0"0'-7"5'-0"0'-11"5'-0"1'-5"4'-11"2'-0"0'-9"
12'-11"7'-8"22'-2"
42'-9"
TITLE 24 ENERGY NOTES:1 - PER SEC. 210.52 (C) OF THE 2013 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS,AT EACH COUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULASPACE 24" BY 12" OR LARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THEWALL LINE IS MORE THAN 24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THATSPACE. COUNTER TOP SPACES SEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALLBE CONSIDERED AS SEPARATE SPACES. RECEPTACLE RENDERED INACCESSIBLE BYAPPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEPICTED SPACE SHALL NOT BECONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2013 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET ISLESS THAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2013 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TOSUPPLY GENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THEFOLLOWING MINIMUM REQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOPSURFACES SHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCHCIRCUIT.5 - PER SEC. 210.52 OF THE 2013 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOMESHALL BE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2013 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETSINSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS,LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2013 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERERECEPTACLES SERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6FT OF THE EDGE OF THE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI)PROTECTION.8 -SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AS REQUIRED, PER SEC. 310.9.1.4 OFTHE 2010 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION. 9 -SMOKE DETECTORS TO BE HARD WIRED AND SHALL RECEIVE THEIR PRIMARY POWER FROMTHE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE ANDSHALL BE EQUIPPED WITH A BATTERY BACK-UP THE DETECTOR SHALL EMIT A SIGNAL WHEN THEBATTERIES ARE LOW., PER SEC. 310.9.1.3 OF THE 2010CBC.10 - PER SEC. 410.8 OF 2013 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWINGCLEARANCES TO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVEAN ENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2013 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED ININSULATED CEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BEAPPROVED FOR INSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2013 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMPLOCATIONS SHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY.LUMINARIES SUBJECT TO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS."LUMINARIES NOT SUBJECT TO SHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WETLOCATIONS" OR "SUITED FOR DAMP LOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOL UNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCIPROTECTED. FIXTURES MAY BE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTEDFOR USE IN DAMPED LOCATIONS AND GFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE ANEFFICACY OF NOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR ANDGFCI PROTECTED.16 -AT LEAST HALF OF THE INSTALLED WATTAGE OF LIGHT FIXTURES IN KITCHENS SHALL BE HIGHEFFICACY AND THOSE THAT ARE NOT MUST BE SWITCHED SEPARATELY. HIGH EFFICACY LIGHTFIXTURES MUST PROVIDE AT LEAST 40 LUMEN PER WATT. ALMOST ALL FLUORESCENT LAMPSEQUIPPED W/ELECTRONIC BALLAST QUALIFY, (VERIFY) INCANDESCENT LAMPS (INCLUDING ANYSCREW IN INCANDESCENT LAMPS) QUARTZ HALOGEN LAMPS OR LOW VOLTAGE LAMPS SUCH ASHALOGEN LAMPS DO NOT.17 -OTHER ROOMS SHALL HAVE LIGHT FIXTURES EITHER BE HIGH EFFICACY (FLUORESCENT) ORSHALL BE CONTROLLED BY AN OCCUPANT SENSOR OR DIMMER. CLOSETS THAT ARE LESS THAN70 SQF, ARE EXEMPT FROM THIS REQUIREMENT. AN APPROVED OCCUPANT SENSOR DOES NOT ALLOW THE LIGHT TOBE TURNED ON AUTOMATICALLY. AND DOES NOT HAVE AN OVERRIDE THAT ALLOWS IT TO REMAINON.18 - ALL OUTDOOR LIGHT FIXTURES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ONTHE SAME LOT SHALL BE HIGH EFFICACY LIGHT FIXTURES (FLUORESCENT) OR SHALL BECONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BEREMOVED BY PG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATEANY OF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOMENTRY DOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLEOUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP. OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,DENS, BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.)SHALL BE A MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW,SKYLIGHT OR ATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING ANDHAVE A BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALLBE REDUCED 2 FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROLVALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH UMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLYWITH CMC 701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITSVERTICAL DIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUMDISTANCE OF 4 INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANTMETAL INSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOWCONDENSATE DUE TO A CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDINGOVERFLOW AND A SECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAINPAN. CMC 309.2 1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BEACCESSIBLY BY AN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THEAPPLIANCE, AND NOT LESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TOTHE FURNACE AND ITS CONTROLS. (CMC 904.11.1)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THECENTER LINE OF THE PASSAGEWAY. ( CMC 904.11.4)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORINGNOT LESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC904.11.3 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALLBE PROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 904.11.4)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCHLOCATED AT THE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 904.11.5)1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE ANDCEILING GYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.ELECTRICAL NOTES:FURNACE INSTALLATION: (In The Attic)MECHANICAL & PLUMBING NOTES:
12'-10" X 3'-6"
12'-3" X 22'-0"
11'-0" X 12'-11"
10'-8" X 10'-8"
9'-7" X 9'-4"
2'-0" X 6'-1"2'-0" X 6'-6"
7'-3" X 7'-6"
7'-3" X 10'-4"
STAIRWELL
BEDROOM
CLOSET
BEDROOM
BEDROOM
CLOSET
MASTER BDRM
MASTER BATH
WALK - IN - CLOSET
1/4 INCH = 1 FEET
0 1 2 3 4 5 10 15
GRAPHIC SCALE :
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
Azadeh Masrour
EXISTING
FLOOR
PLAN
RA-01.01
1/4" = 1'
NORTH
LEGEND:
EXISTING WALL TO BE REMOVED
SMA
1
SC : 1/8" = 1'-0"
EXISTING SITE PLAND/WREF.3080505016080
60803080
5050
3080
6080
3080465050332480
2680
2580
6080
5050
5050288024802580
UP
SKYLIGHTS SHALL BE TESTED AND
APPROVED, BEARING A LABEL INDICATING
COMPLIANCE WITH THE REQUIREMENTS
OF AAMA/WDMA/CSA 101/I.S.2/A440. [CRC
§R308.6.9]
FRONT YARD:60'X20'= 1200 SQF
PAVING AREA:
DRIVE WAY/ WALKWAY(440)/1200=36.6%<50%
FRONT YARD PAVING SURFACE AREA:
STREET TREE TO BE INSTALLED BY THE CITY. UPON PROJECT COMPLETION, THE PROPERTY OWNER SHALL PREPARE AN
ADEQUATE PLANTING AREA AND CONTACT THE CITY AT 408-777-3269 TO ARRANGE FOR THE TREE INSTALLATION
1 - PER SEC. 210.52 (C) OF THE 2016 CEC, IN KITCHENS AND DINING AREAS OF DWELLING UNITS, AT EACHCOUNTER SPACE WIDER THAN 12" AND AT EACH ISLAND COUNTER OR PENINSULA SPACE 24" BY 12" ORLARGER RECEPTACLE SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN24', MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. COUNTER TOP SPACESSEPARATED BY RANGE TOPS, REFRIGERATORS, OR SINKS SHALL BE CONSIDERED AS SEPARATESPACES. RECEPTACLE RENDERED INACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCESOCCUPYING DEPICTED SPACE SHALL NOT BE CONSIDERED AS THESE REQUIRED OUTLETS.2 - PER SEC. 210.52 (C) (5) OF THE 2016 CEC, ISLAND/PENINSULA'S OVERHANG ABOVE OUTLET IS LESSTHAN 6-INCHES AND OUTLET IS LESS THAN 12-INCHES BELOW THE COUNTERTOP.`3 - PER SEC. 210.11 AND 422.12 OF 2016 CEC, IN ADDITION TO BRANCH CIRCUITS INSTALLED TO SUPPLYGENERAL ILLUMINATION AND RECEPTACLE OUTLETS IN DWELLING UNITS, THE FOLLOWING MINIMUMREQUIREMENTS APPLY: TWO 20-AMP CIRCUITS FOR THE KITCHEN RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE LAUNDRY RECEPTACLES. ONE 20-AMP CIRCUIT FOR THE BATHROOM RECEPTACLES. ONE SEPARATE, INDIVIDUAL BRANCH CIRCUIT FOR CENTRAL HEATING EQUIPMENT.4 - PER SEC. 210.52 RECEPTACLES INSTALLED IN THE KITCHEN TO SERVE COUNTERTOP SURFACESSHALL BE SUPPLIED BY NOT LESS THAN TWO SEPARATE SMALL APPLIANCE BRANCH CIRCUIT.5 - PER SEC. 210.52 OF THE 2016 CEC, ALL RECEPTACLES AT THE FRONT AND REAR OF THE HOME SHALLBE WITHIN 6 FEET 6 INCHES OF GRADE AND THEY ARE TO BE WEATHER PROOFED GFCI. 6 - PER SEC. 210.12 (B) OF THE 2016 CEC, ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS PARLORS, LIBRARIES, DENS,BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER.7 - PER SEC. 210.8 OF THE 2016 CEC, ALL RECEPTACLES IN BATHROOMS, GARAGE, ACCESSORYBUILDINGS, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENT, KITCHENS (WHERE RECEPTACLESSERVE COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6 FT OF THE EDGE OFTHE SINK), SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION.8 - SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM AND AT A POIT CENTRALLYLOCATED IN CORRIDORS GIVING ACCESS TO SUCH ROOMS AND EACH STORY WITHIN DWELLING UNIT,INCLUDING BASEMENT BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS AS REQUIRED,PER SEC. 314.3 OF THE 2016 CBC, AND IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION.9 - FOR NEW CONSTRUCTION,SMOKE DETECTORS AND CARBON MONOXIDE ALARMS TO BE HARD WIREDAND SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING ISSERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP THEDETECTOR SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW., PER SEC. 314.5 & 315.1.1,2 OF THE2016CBC.9A - APPROVED CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATESLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND EVERY LEVEL INCLUDINGBASEMENTS IN DWELLING UNITS THAT HAVE FUEL-FIRED APPLICATIONS OR ATTACHED GARAGE.9B - SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNERTHAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS. [CRC §R314.6 & 315.7] 10 - PER SEC. 410.8 OF 2016 CEC, LUMINARIES IN CLOSETS SHALL HAVE THE FOLLOWING CLEARANCESTO COMBUSTIBLE/SHELVESA. SURFACE-MOUNTED INCANDESCENT FIXTURES SHALL HAVE 12' CLEARANCE AND HAVE ANENCLOSED BULB.B. FLUORESCENT FIXTURES AND RECESSED TO HAVE MINIMUM 6' CLEARANCE. 11 PER SEC. 410.66 OF THE 2016 CEC, ALL RECESSED LIGHTING FIXTURE INSTALLED IN INSULATEDCEILING OR INSTALLED WITHIN 1/2-INCHE OF COMBUSTIBLE MATERIAL SHALL BE APPROVED FORINSULATION CONTACT AND LABLED TYPE IC.12 - PER SEC. 410.4 (A) AND (D) OF 2016 CEC, ALL LUMINARIES INSTALLED IN WET OR DAMP LOCATIONSSHALL BE LISTED FOR SUCH USE BY AN APPROVED AND RECOGNIZED AGENCY. LUMINARIES SUBJECTTO SHOWER SPRAY MUST BE LISTED "SUITED FOR WET LOCATIONS." LUMINARIES NOT SUBJECT TOSHOWER SPRAY CAN BE LISTED AS EITHER "SUITED FOR WET LOCATIONS" OR "SUITED FOR DAMPLOCATIONS.13 -LIGHT FIXTURES INSTALLED ABOVE AND WITHIN 5'-0' FROM INSIDE WALLS OF THE SPA/WHIRLPOOLUNIT SHALL BE AT LEAST 7'-6' ABOVE THE MAXIMUM WATER LEVEL AND FFCI PROTECTED. FIXTURES MAYBE INSTALLED LESS THAN 7'-6' PROVIDED THAT THEY ARE LISTED FOR USE IN DAMPED LOCATIONS ANDGFCI PROTECTED. 14 -LAMP USED FOR GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE AN EFFICACY OFNOT LESS THAN 40 LUMENS PER WATT, PER TITLE 24, 2.5352 (J). 15 -ALL RECEPTACLES TO BE INSTALLED IN GARAGE TO BE MIN. 18' ABOVE FINISH FLOOR AND GFCIPROTECTED. 16 -ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY IN ACCORDANCE WITH CENC TABLE 150.0-A.[CENC §150.0(K)1A] 16A -LIGHTING REQUIRED TO COMPLY REFERENCE JOINT APPENDIX JA8 PER CENC TABLE 150.0-ASHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. [CENC §150.0(K)2K] 17 -IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE INEACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. [CENC §150.0(K)2J] 17A -WITH THE 2016 CENC, ALL INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY; THEREFORE, THE50% REQUIREMENT IN THE KITCHEN IS NO LONGER APPLICABLE. [CENC §150.0(K)1A] 18- PERMANENTLY MOUNTED OUTDOOR LIGHTING SHALL BE HIGH EFFICACY IN ACCORDANCE WITHCENC TABLE 150.0-A AND MEET THE REQUIREMENTS PER CENC §150.0(K)3A. 19 -FOR EXISTING BUILDINGS TO BE REMOVED GAS AND ELECTRICAL METER ARE TO BE REMOVED BYPG&E PRIOR TO ANY DEMOLITION OR CONSTRUCTION ACTIVITY.20 -CONTRACTOR NEEDS TO VERIFY AND CONFIRM THE LOCATION OF ALL LIGHT SWITCHES ANDPROVIDE ANY ADDITIONAL OUTLETS OTHER THAN SHOWN ON THIS DRAWING. DO NOT ELIMINATE ANYOF THE OUTLETS SHOWN ON THIS DRAWING.21 -BOTTOM OUTPUT OF ALL ELECTRICAL OUTLETS BY THE HEADBOARD LOCATIONS OF BEDS INBEDROOMS AND GUEST ROOMS TO BE SWITCH OPERATED, SWITCH LOCATED BY THE ROOM ENTRYDOOR.22 -PER CEC ARTICLE 406.11, ALL 15-AMP AND 20 AMP DWELLING UNIT RECEPTACLE OUTLETS SHALL BELISTED TAMPER-RESISTANT RECEPTACLES.23 -PER CEC ARTICLE 406.11, ALL 125-VOLT, 15-AND 20-AMP DWELLING UNIT RECEPTACLE OUTLETSSHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.24 -PER CEC 210.12(B), ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE PHASE, 15- AND 20-AMP.OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS,BEDROMMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREASSHALL BE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTED.CONTRACTOR NEEDS TO VERIFY AND CONFIRM WITH THE OWNER WHETHER ANY LOW VOLTAGENETWORK AND SECURITY SYSTEM IS TO BE PROVIDED AND INSTALLED.COORDINATE AND VERIFY WITH OWNER FOR ANY OTHER OUTLET TO BE SWITCHED.
1 -TERMINATION OF ALL ENVIRONMENTAL AIR DUCTS (DRYERS, BATH AND UTILITY FANS, ETC.) SHALL BEA MINIMUM OF 3 FEET FROM ANY OPENNINGS INTO THE BUILDING (DOORS, WINDOW, SKYLIGHT ORATTIC VENTS).2 -CLOTHES DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE ABACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 WITH TWO ELBOWS. THIS SHALL BE REDUCED 2FOR EVERY ELBOW IN EXCESS OF TWO. CMC 504.3.23 -SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVESOF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE.4 -FUEL GAS PIPING FOR THE WATER HEATER AND FURNACE SHALL COMPLY WITH CMC.5 -COMBUSTION AIR OPENING SIZES AND LOCATIONS AT MECHANICAL ROOM SHALL COMPLY WITH CMC701 THROUGH CMC 707 AND CPC 507.1.1 FOR FURNACE AND WATER HEATER.6 -PROVIDE SEISMIC STRAPPING AT WATER HEATER. SEISMIC ANCHORAGE OF WATER HEATER TOINCLUDE ANCHORS OR STRAPS AT POINTS WITHIN THE UPPER AND LOWER ONE THIRD OF ITS VERTICALDIMENTION, THE LOWER ANCHOR OR STRAP BEING LOCATED TO MAINTAIN A MINIMUM DISTANCE OF 4INCHES ABOVE THE CONTROLS. SEE IPC.7 -SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLING AND RESIDENTIALOCCUPANCIES. CMC 802.7.4.18 -COOLING UNITS SHALL HAVE AN ADDITIONAL WATERTIGHT PAN OF CORROSION-RESISTANT METALINSTALLED BENEATH THE COOLING COIL OR UNIT TOP TO CATCH THE OVER FLOW CONDENSATE DUE TOA CLOGGED PRIMARY CONDENSATE DRAIN, OR ONE PAN WITH A STANDING OVERFLOW AND ASECONDARY DRAIN MAY BE PROVIDED IN LIEU OF THE SECONDARY DRAIN PAN. CMC 309.2
1 -AN ATTIC OR FURRED SPACE IN WHICH A WARM-AIR FURNACE IS INSTALLED SHALL BE ACCESSIBLY BYAN OPENING AND PASSAGEWAY AS LARGE AS THE LARGES COMPONENT OF THE APPLIANCE, AND NOTLESS THAN 22 INCHES X 30 INCHES CONTINUOUS FROM THE OPENING TO THE FURNACE AND ITSCONTROLS. (CMC 304.4)2 -WHERE THE HEIGHT OF THE PASSAGEWWAY IS LESS THAN 6 FEET, THE DISTANCE FROM THEPASSAGEWAY ACCESS TO THE APPLIANCE SHALL NOT EXCEED 20 FEET MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY. ( CMC 304.4.1)3 -THE PASSAGEWAY SHALL BE UNOBSTRUCTED AND SHALL HAVE CONTINUOUS SOLID FLOORING NOTLESS THAN 24 INCHES WIDE FROM THE ENTRANCE OPENING TO THE FURNACE. ( CMC 304.2 )4 -A LEVEL WORKING PLATFORM OR GRADE SURFACE NOT LESS THAN 30 INCH X 30 INCH SHALL BEPROVIDED IN FRONT OF THE SERVICE SIDE OF THE APPLIANCE. (CMC 304.4.3)5 -A PERMANENT ELECTRIC OUTLET AND A LIGHTING FIXTURE CONTROLLED BY A SWITCH LOCATED ATTHE ATTIC ACCESS SHALL BE PROVIDED AT OR NEAR THE FURNACE. (CMC 304.4.4)
1 - PROPOSED CAN LIGHTS SHELL BE AT & IC RATED AND CAULKED BETWEEN THE FIXTURE AND CEILINGGYP BOARD.2 - LIGHTING IN THE KITCHEN SHALL BE HIGH EFFICACY.
ELECTRICAL NOTES:
TITLE 24 ENERGY NOTES:
FURNACE INSTALLATION: (In The Attic)
MECHANICAL & PLUMBING NOTES:
- THE EXHAUST FANS IN BATHROOMS WILL BE ENERGY STAR COMPLIANT, TERMINATE OUTSIDE THE BUILDING, ANDWILL BE CONTROLLED BY A HUMIDITY CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGEOF 50 PERCENT TO 80 PERCENT. [CGBSC §4.506.1] - THE EXHAUST FANS IN BATHROOMS SHALL BE A MINIMUM EXHAUST RATE OF 50 CUBIC FEET PER MINUTE . [CMCTABLE 403.7]
BUILDING NOTES:1- BASEMENTS (EXCEPT THOSE ONLY FOR MECHANICAL EQUIPMENT AND NOT OVER200 SQFT IN FLOOR AREA), HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALLHAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. R310.1a.MIN. NET CLEAR OPENABLE DIMENSION OF 24 INCHES IN HEIGHT. R310.1.2b.MIN. NET CLEAR OPENABLE DIMENSION 20 INCHES IN WIDTH. R310.1.3c.MIN. NET CLEAR OPENABLE DIMENSION OF 5.7 SQFT IN AREA. GRADE FLOOROPENINGS SHALL HAVE A MIN. NET CLEAR OPENING OF 5 SQFT. 310.1.1d.THE HEIGHT OF BOTTOM OF EMERGENCY EGRESS OPENING SHALL HAVE NOTMORE THAN 44 INCHES MEASURED FROM THE FLOOR. 310.2.22- FOR KITCHEN, A CLEAR PASSAGEWAY OF NOT LESS THAN 3-FEET BETWEEN THECOUNTER FRONTS AND APPLIANCES OR COUNTER FRONTS AND WALLS. CBC 1208.13- SHOWER COMPARTMENTS AND WALL ABOVE BATHTUBES WITH INSTALLED SHOWERHEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO THEHEIGHT NOT LESS THAN 72 INCHES(6 FT). CRC R307.2 4- THE DOOR BETWEEN GARAGE AND ENTRY REQUIRED TO BE SELF LATCHING ANDSELF CLOSING, SOLID CORE DOOR NOT LESS THAN 1-3/8 INCH THICK.5- THE MAXIMUM RISER HEIGHT CAN BE 7.75-INCHES. MINIMUM TREAD DEPTH CAN BE10-INCHES. FOR ANY TREAD DEPTH LESS THAN 11-INCHES, A NOSING OF NOT LESSTHAN 0.75-INCHES, BUT NOT MORE THAN 1.25-INCHES SHALL BE PROVIDED.
6- DOORS AND PANELS OF SHOWER AND BATHTUB ENCLOSURES SHALL BE FULLYTEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3.GLAZING IN SHOWERS OR BATHTUB ADJACENT WALL OPENINGS WITHIN 60 INCHESABOVE A STANDING SURFACE AND DRAIN INLET SHALL BE FULLY TEMPERED,LAMINATED SAFETY GLASS OR APPROVED PLASTIC. CBC 2406.3, #57- GLAZING IN AN INDIVIDUAL FIXED OR PORTABLE PANEL ADJACENT TO A DOORWHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN A 24-INCH ARC OFEITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THEBOTTOM EXPOSED EDGE OF GLAZING IS LESS THAN 60-INCHES ABOVE THE WALKINGSURFACE SHALL BE FULLY TEMPERED, LAMINATED SAFETY GLASS OR APPROVEDPLASTIC ( I.E. SIDE LIGHT AT NEW MAIN ENTRY DOOR) . CBC 2406.3, #68- MINIMUM 36" DEEP LANDING IN THE DIRECTION OF TRAVEL AT NEW EXTERIORDOORS SHALL BE PROVIDED. LANDING TO BE NOT MORE THAN 7-¾ INCHES LOWERTHAN THE DOOR'S THRESHOLD FOR IN-SWINGING AND SLIDING GLASS DOORS ANDNOT MORE THAN 7" FOR IN-SWINGING AND MAIN ENTRY DOOR.
9- NEW ENTRY DOOR SHALL BE OPENABLE FROM THE INSIDE OF THE DWELLINGWITHOUT USE OF KEY, SPECIAL KNOWLEDGE OR EFFORT. CRC SEC. R311.210- 1/2" GYPSUM BOARD FROM FOUNDATION TO ROOF SHEATHING TO BE INSTALLEDON THE GARAGE SIDE AT SEPARATION WALL BETWEEN GARAGE AND RESIDENCE.(GARAGE MUST BE SEPARATED FROM THE DWELLING AND ITS ATTIC AREA) CRC SEC.R302.6 AND TABLE R302.6ALSO 5/8" TYPE "X" GYP. BOARD FINISH ON THE GARAGE SIDE OF THE WALL ISREQUIRED.
11- BATHROOMS & KITCHEN:11.1- 22" MIN SHOWER DOOR CLEARANCE.11.2- TEMPER GLAZING FOR THE SHOWER DOOR AND SLIDING WINDOWS.CEMENT BOARD SUBSTRATE FOR SHOWER WALLS.11.3- LAVATORY FAUCETS TO HAVE A FLOW RATE OF NO MORE THAN 1.2 GPM OR LESSAT 60 PSI AND NOT LESS THAN 0.8 GPM OR LESS AT 20 PSI. (CALGREEN 4.303.1)11.4- WATER CLOSETS TO HAVE A FLOW RATE OF 1.28 GALLONS/FLUSH OR LESS.(CALGREEN 4.303.1)11.5 -CEMENT BOARD SUBSTRATE (IE. DUROCK OR WONDERBOARD,ETC) FOR TILEAPPLICATION SURROUNDING THE BATH TUB WALLS .11.6- KITCHEN FAUCETS TO HAVE A FLOW RATE OF 1.8 GPM OR LESS AT 60 PSI.(CALGREEN 4.303.1)11.7- SHOWER HEAD TO HAVE A FLOW RATE NOT TO EXCEED OF 2 GPM AT 80 PSI.(CALGREEN 4.303.1)
FLOOR FINISHES:
FIRE PLACE NOTES:CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTEDGAS FIREPLACES.FEATURES:64% STEADY STATE MAXIMUM EFFICIENCY WITH 17,000 BTUS TOP OR REAR VENT 100% SAFE GUARD™ SAFETY GAS CONTROL QUICKLY AND AUTOMATICALLY SHUTS OFF GASSUPPLY FLAME AND HEAT ADJUSTMENT FOR MAXIMUM COMFORT AND EFFICIENCY THE GAS FIRE PLACE MUST BE DIRECT VENT, PER CURRENT 2016 ENERGY CODEHEAVY-GAUGE PAN BURNER SYSTEM WORKS WITH 4" BY 7" PIPE N87°39'53"W 163.88'FRONT YARD:1180 SQF
PAVING AREA:
DRIVE WAY/ WALKWAY(368+42)/1180=34.7%<40%
FRONT YARD PAVING SURFACE AREA:APN NO.: 375-36-014LOT GROSS AREA: 5,857%%P SFLOT 233R1LOT 234R1LOT 232R1JOHANSEN DRIVELOT GROSS AREA: 5,857%%P SFLOT 231R1(BASIS OF BEARINGS)3030EMEX. HOUSEEX. GARAGEEX. CONC.EX. DRIVEWAYFF 101.53GFF 100.85 GEX. CONC.EX. CONC.EX. CONC.EX. CONC.EX. PORCHJOHANSEN DRIVEAPN NO.: 375-36-014LOT GROSS AREA: 5,857%%P SFLOT 233R1LOT 234R1LOT 232R1LOT 231R1N87°39'53"W 163.88'L=132.36'R=150.00'Δ=50°33'29"L=280.89'R=890.00'Δ=18°04'59"N66°18'21"W 70.00'L=57.95' R=890.00'Δ=3°43'51"N61°23'53"W 105.00(R) R1N31°38'31"E 51.76' R1N57°28'02"W 105.97' R1L=59.00'R=860.00'Δ=3°55'51"R1N31°38'31"E 28.49'N56°16'11"W 106.69'N38°55'36"E 28.41'100.2100.6100.299.2100.8100.8100.9100.9100.9101.9100.8100.7100.7100.6N45°09'15"E 298.46' CALCED PER R1N45°09'15"E 298.46' M-ML=37.02'R=20.00'Δ=106°02'42"L=37.02'R=20.00'Δ=106°02'42"L=172.44'R=45.00'Δ=219°33'06"L=230.45'R=920.00'Δ=14°21'08"59.00'
51.76'105.97'105'20'-0" X 20'-1"21'-9" X 20'-7"
30'-4" X 14'-10"
11'-9" X 8'-11"
10'-6" X 10'-10"
LIVING GARAGE
DINING
KITCHEN
FAMILY
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
"E"TREE TO BE REMOVED
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
REVISION TABLE:
DRAWN BY :
REVISION DATE
JOHANSEN'S
RESIDENCE
AMS
10592 JOHANSEN DR.,
CUPERTINO, CA
REMODELING FOR:
BY
OWNERSHIP:
DESIGN
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
SCALE :
PROJECT ID :
DATE :
SHEET NUMBER:
D-1810-02
DEC. 2018
A.M.S
ADDITION and REMODELING FOR:
SHEET TITLE:
DESIGN
21060 HOMESTEAD RD. SUITE 216
CUPERTINO, CA 95014
TEL:(408) 992-1229
e-MAIL: NILSENEINC@GMAIL.COM
Azadeh Masrour
EXISTING
SITE
PLAN
RA-01.02NORTH
SMA