Loading...
R-2019-016 Approved Plan SetG-001 G-101 SV-1 A-001 A-002 A-003 A-121 A-122 A-123 A-124 A-201 A-202 A-203 A-301 A-302 A-601 L-101 COVER SHEET CITY OF CUPERTINO: CONSTRUCTION BEST MANAGEMENT PRACTICES SURVEY EXISTING SITE PLAN SITE PLAN PUBLIC WORKS NOTES & SITE DETAILS FOUNDATION PLAN LEVEL 1 FLOOR PLAN LEVEL 2 FLOOR PLAN ROOF PLAN ELEVATIONS ELEVATIONS ELEVATIONS SECTIONS SECTIONS SCHEDULES CONCEPTUAL LANDSCAPE PLAN ROOM XXX XXX sq ft X A-XXX X A-XXX X" X A-XXX X A-XXX X X X X A-XXX XXX XXX XXX XXX XX-1 XX WALL SECTION TAG ELEVATION TAG NEW DOOR TAG EXISTING DOOR TAG EXISTING GLAZING TAG ROOM TAG LEVEL DIMENSION NEW GLAZING TAG ASSEMBLY TAG EXIT SIGN EXISTING MASONRY WALL DEMOLISHED WALL DEMOLISHED FLOOR/SLAB/INFILL WALL EXISTING CONCRETE WALL MATERIAL TAG EXISTING FRAMED WALL NEW MASONRY WALL NEW CONCRETE WALL NEW FRAMED WALL SYMBOL REFERENCE: DETAIL TAG INTERIOR ELEVATION TAG GRID LINE ENLARGED PLAN TAG X 02 NOT TO SCALE 2 LOCATION PLAN NOT TO SCALE1PERSPECTIVE PROJECT DESCRIPTION: NEW SINGLE FAMILY RESIDENCE PROJECT ADDRESS: 10385 MENHART LANE CUPERTINO CA 95014 USA LEGAL DESCRIPTION: LOT 94, TRACT 1004 ASSESSOR'S PARCEL NUMBER: 375-15-047 EASEMENTS: NONE OWNER: BERT CHEN BERTCHEN@GMAIL.COM 408.256.3779 10385 MANHART LANE CUPERTINO CA 95014 PROJECT MANAGER: SHED ARCHITECTURE & DESIGN CONTACT: CLAYTON HERBST clayton@shedbuilt.com 206.890.8583 1401 S JACKSON SEATTLE WA 98144 STRUCTURAL ENGINEER: TODD PERBIX TWP@TWPERBIX.COM 206.601.9099 ENERGY CONSULTANT: BEYOND EFFICIENCY CONTACT: DAN JOHNSON DAN@BEYONDEFFICIENCY.US 415.236.1333 710 CHANNING WAY, BERKLEY CA 94710 ZONING: R1-5 LOT AREA: 5,012 SQFT LOT COVERAGE: ALLOWABLE: 45% OF THE NET LOT AREA (ADDITIONAL 5% FOR ROOF OVERHANGS, PATIOS AND PORCHES) EXISTING TOTAL: 1,276 SQFT PROPOSED TOTAL: 1,859 SQFT < 2,255 SQFT ALLOWABLE FIRST FLOOR SETBACKS: FRONT: 20' SIDES: 5' BACK: 20' SECOND FLOOR SETBACKS: FRONT: 25' SIDES: 25' COMBINED (NO SIDE YARD SETBACK SHALL BE LESS THAN 10') BACK: 25' HEIGHT: AVERAGE GRADE: 181.8' MAX ALLOWABLE HEIGHT: 28' PROPOSED HEIGHT: 25' 6" CONSTRUCTION TYPE: VB OCCUPANCY TYPE: R-3,U STORIES: 2 DWELLINGS: 1 BEDROOMS: 3 BATHROOMS: 3 DISTURBED AREA: xxxx SF NEW OR REPLACED IMPERVIOUS AREA: xxxx SF EXCAVATION: CUT: xxx CUBIC YARDS STORMWATER MANAGEMENT: SANITARY SEWER: ALL NEW TREES OR PLANTINGS TO BE CHOSEN FROM APPROVED CUPERTINO SPECIES. TBD HEATING SYSTEM: TBD SPEC: TBD MECHANICAL VENTILATION: TBD AIR INTAKE: TBD ELECTRICAL: TBD PROGRAMMABLE THERMOSTAT: TBD THE PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: 2016 CBC - CALIFORNIA BUILDING CODE 2016 CRC - CALIFORNIA RESIDENTIAL CODE 2016 CEC - CALIFORNIA PLUMBING CODE 2016 CEC - CALIFORNIA MECHANICAL CODE 2016 CMC - CALIFORNIA ELECTRICAL CODE 2016 CPC - CALIFORNIA ENERGY CODE 2016 CGBSC - CALIFORNIA GREEN BUILDING STANDARDS CODE CITY OF CUPERTINO, CALIFORNIA MUNICIPAL CODE ROOF VENTILATION: TBD CHEN RESIDENTIAL DESIGN REVIEW SHEET INDEX: GENERAL NOTES: THE DRAWINGS ARE INTENDED TO ONLY PARTIALLY DESCRIBE THE SCOPE OF WORK FOR THE PROJECT. ANY WORK NOT SHOWN HERE, BUT REQUIRED BY CODE, OR THE SPECIFICATIONS, OR TO MAKE THE WORK COMPLETE, SHALL BE PROVIDED AS PART OF THE WORK. REFER TO THE LIST OF ABBREVIATIONS FOR COMMON ABBREVIATIONS USED IN THE DRAWINGS. IF AN ABBREVIATION IS NOT ON THE LIST, OR NOT COMMONLY USED, REFER TO THE ARCHITECT FOR CLARIFICATION. IT IS THE INTENT OF THE DOCUMENTS THAT ALL WORK COMPLIES WITH THE CALIFORNIA BUILDING CODE, CALIFORNIA RESIDENTIAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA MECHANICAL CODE, CALIFRONIA ELECTRICAL CODE, CALIFORNIA ENERGY CODE, CITY OF CUPERTINO MUNICIPAL CODE... AND ALL APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES IN EFFECT AT THE DATE OF PERMIT SUBMITTAL. NOTHING IN THESE DRAWINGS SHALL BE CONSTRUED TO GRANT APPROVAL FOR ANY CODE VIOLATION. ANY ERRORS, INCONSISTENCIES OR OMISSIONS SHALL BE REPORTED PROMPTLY TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. IF DISCREPANCIES ARE FOUND, THE ARCHITECT SHALL BE NOTIFIED AT ONCE. CONTRACTOR SHALL VERIFY THE DIMENSIONS REQUIRED FOR ALL EQUIPMENT, APPLIANCES, FIXTURES, CABINETS, DUCTWORK, AND OPENINGS BEFORE FRAMING BEGINS. THE CONTRACTOR SHALL COORDINATE WITH THE SUBCONTRACTORS OF ALL TRADES TO VERIFY THE SIZES AND LOCATIONS OF O [ENINGS THROUGH THE FLOORS, WALLS, CEILINGS, AND ROOFS FOR DUCTS, PIPES, CONDUITS, AND EQUIPMENT. THE CONTRACTOR SHALL COORDINATE THE LOCATION AND INSTALLATION OF WOOD BACKING, BLOCKING, FURRING, AND STRIPPING AS REQUIRED FOR THE INSTALLATION AND ATTACHMENT OF WORK OF ALL TRADES. PROVIDE FIRE RESISTANCE CLOSURE MEETING THE REQUIREMENTS OF THE GOVERNING FIRE AUTHORITIES AT ALL GAPS AROUND PENETRATING DUCTS, PIPES, CONDUITS, ETC.. AT ALL FIRE RATED BUILDING WALLS, PARTITIONS, CEILINGS, FLOORS AND ROOFS. COORDINATE WITH MECHANICAL AND ELECTRICAL CONTACTORS FOR EXACT LOCATIONS, TYPES AND SIES OF ACCESS DOORS REQUIRED BY THEIR WORK. PROVIDE ACCESS FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGE, ELECTRICAL JUNCTION BOXES, ETC.. DRAWINGS MAY NOT SHOW ALL REQUIRED ACCESS PANELS. INDICATE REQUIRED ACCESS DOORS ON THE COORDINATION DRAWINGS. OBTAIN ARCHITECT'S APPROVAL FOR LOCATIONS OF ACCESS DOORS PRIOR TO INSTALLATION. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND GOVERNMENTAL FEES, LICENSES AND INSPECTIONS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK, WITH THE EXCEPTION OF THE MATER USE PERMIT AND THE BUILDING PERMIT PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION OR SITE DEVELOPMENT ACTIVITY, THE CONTRACTOR SHALL SCHEDULE PRE-CONSTRUCTION MEETINGS WITH THE APPROPRIATE REGULATORY ENTITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION OR SITE DEVELOPMENT ACTIVITY, THE CONTRACTOR AND/OR ARCHITECT SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE PROJECT TEAM MEMBERS FOR THE PURPOSE OF ANSWERING INITIAL QUESTIONS, CLARIFYING AREAS OF CONCERN, AND FORMALIZING A CONSTRUCTION ADMINISTRATION PROCESS. THE MEETING SHALL INCLUDE THE ARCHITECT, GENERAL CONTRACTOR, OWNER, LANDSCAPE ARCHITECT, STRUCTURAL ENGINEER, CIVIL ENGINEER, GEOTECHNICAL ENGINEER, AND WATER INTRUSION CONSULTANT 1 . 2. 3. 4. 5. 6. 7. 8. 9. 1 0. PROJECT INFO: CODES: BUILDING NOTES: PROJECT CONTACTS: LAND USE NOTES: ENERGY CODE NOTES: DRAINAGE NOTES: VENTILATION NOTES: LANDSCAPE NOTES: MECH. & ELEC. NOTES: G-001 COVER SHEET SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:32 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano G-101 R-2019-016 01/29/20 Erick Serrano XXX PROPERTY LINE ENTRY SITE PLAN LEGEND: PROPOSED STRUCTURE NEIGHBORING STRUCTURES (N) BRICK PAVING (E) BRICK PAVING SITE PLAN NOTES: SEE SURVEY FOR ADDITIONAL EXISTING SITE INFORMATION ALL MEASUREMENTS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. 1. 2. CONCRETE PAVING ELECTRIC METER TO BE REMOVED GAS METER TO BE REMOVED POWER POLE AND OVERHEAD ELECTRIC SERVICE SINGLE FAMILY RESIDENCE 10385 MENHART LANE APC: 375-15-047 DRIVEWAY TO BE REMOVED REMOVE SHED REMOVE CONCRETE PAD EXISTING PUBLIC STREET TREE TO BE REMOVED PER PUBLIC WORKSMENHART LANE10379 MENHART LANE (E) SINGLE FAMILY RESIDENCE 10391 MENHART LANE (E) SINGLE FAMILY RESIDENCE N 0 4' 8' 12' SCALE: 3/16" = 1'-0" 1 EXISTING/DEMO SITE PLAN A-001 EXISTING SITE PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:32 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano XXX PROPERTY LINE ENTRY SITE PLAN LEGEND: PROPOSED STRUCTURE NEIGHBORING STRUCTURES (N) BRICK PAVING (E) BRICK PAVING SITE PLAN NOTES: SEE SURVEY FOR ADDITIONAL EXISTING SITE INFORMATION ALL MEASUREMENTS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. 1. 2. CONCRETE PAVINGENTRANCE20' 25' 188'-1 1/4" 188'-4" 1 87'-3" 187' DRIVEWAY TBD ROOF ABOVE RAISED PORCH 188'188'188'1 8 8' (E) CONC. SIDEWALK (E) ROLLED CONC. CURB GUTTER STUCCO LANDSCAPE WALL PROPERTY LINE 97.70' PROPERTY LINE 97.70'PROPERTY LINE 51.18'PROPERTY LINE 51.18'CURB CUR PER CUPERTINO PUBLIC WORKS DETAILS (E) POWER POLE AND OVERHEAD POWER (E) FENCE TO REMAIN MENHART LANER 20' 25'5' 15'10'5'CONCRETE BENCH FRONTYARD TREE ENTRY BENCH ORNAMENTAL GATE TO HOUSE 1ST FLR FRONT SETBACK LINE OF SECOND FLOOR ABOVE 2ND FLR FRONT SETBACK 1ST FLR SIDE SETBACK 2ND FLR SIDE SETBACK 1ST FLR SIDE SETBACK 2ND FLR SIDE SETBACK 1ST FLR REAR SETBACK 2ND FLR REAR SETBACK LINE OF SECOND FLOOR ABOVE OPENING IN LANDSCAPE WALL, REFER TO ELEV COURTYARD TREE 10' PUBLIC UTILITY EASEMENT NEW PUBLIC STREET TREE LINE OF AWNING ABOVE 10379 MENHART LANE (E) SINGLE FAMILY RESIDENCE 10391 MENHART LANE (E) SINGLE FAMILY RESIDENCE 10385 MENHART LANE (N) SINGLE FAMILY RESIDENCE ZONING R1-5 GARAGE 439 sq ft 1,060 sq ft 756 sq ft 2ND FLOOR GARAGE 1ST FLOOR FLOOR AREA RATIO 45% OF THE NET LOT ALLOWABLE 5,012 SQFT LOT 5,012 X .45 = 2,255 SQFT ALLOWABLE 1ST FLOOR = 1,060 SQFT GARAGE = 439 SQFT 2ND FLOOR = 756 SQFT PROPOSED FLOOR AREA = 2,255 SQFT 2,255 SQFT < 2,255 SQFT OK SECOND TO FIRST FLOOR RATIO 2ND FLOOR MUST BE 66% OF THE 1ST FLOOR 1ST FLOOR = 1,060 SQFT GARAGE = 439 SQFT TOTAL = 1,499 2ND FLOOR = 756 SQFT 2ND TO 1ST FLOOR RATIO = 50.4% 50.4% < 66% OK 1,838 sq ft LOT COVERAGE 45% OF THE NET LOT ALLOWABLE 5,012 SQFT LOT 5,012 X .45 = 2,255 SQFT ALLOWABLE LOT COVERAGE = 1,838 SQFT 1,838 < 2,255 ALLOWABLE OK 20' 25' 25' 20'15'5'2ND FLR SIDE SETBACK 1ST FLR SIDE SETBACK 2ND FLR FRONT SETBACK1ST FLR YARD SETBACK2ND FLR REAR SETBACK1ST FLR REAR SETBACK2ND STORY SIDE SETBACK 1ST FLR SIDE SETBACK 2ND FLOOR GARAGE1ST FLOOR 10'5'N 0 4' 8' 12'SCALE: 3/16" = 1'-0" 1 SITE PLAN 0 8' 16' 32'SCALE: 1/16" = 1'-0" 4 F.A.R. DIAGRAM 0 8' 16' 32' SCALE: 1/16" = 1'-0" 2 LOT COVERAGE 0 8' 16' 32' SCALE: 1/16" = 1'-0" 3 SETBACK DIAGRAM A-002 SITE PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:32 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano A-003 PUBLIC WORKS NOTES & SITE DETAILS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano PLAN NOTES: ALL DIMS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. ALL INDICATED ALIGNMENTS ARE TO F.O. FINISH WINDOW OPENING DIMENSIONS ARE MEASURED FROM THE ROUGH OPENING - REFER TO WINDOW/DOOR SCHEDULES FOR ADDITIONAL INFO REFER TO STRUCTURAL FOR FRAMING INFO ALL FLOOR TRANSITIONS SHALL BE AT CENTER OF DOOR, U.N.O. REFER TO ASSEMBLIES FOR WALL THICKNESSES AND FRAMING DIMENSIONS 1. 2. 3. 4. 5. 6. 1A-3011A-3013 A-302 3 A-302 2A-3012A-3012A-3012A-3011 A-201 2 A-201 2 A-202 1 A-202 1 A-203 3 A-203 2 A-203 STRUCTURAL FOOTING TYP. REFER TO STRUCTURAL DRAWINGS 33 11 44 A A C C 22 E E F F 55 D D B B N 0 2' 4' 8' SCALE: 1/4" = 1'-0" 1 FOUNDATION PLAN A-121 FOUNDATION PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano PLAN NOTES: ALL DIMS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. ALL INDICATED ALIGNMENTS ARE TO F.O. FINISH WINDOW OPENING DIMENSIONS ARE MEASURED FROM THE ROUGH OPENING - REFER TO WINDOW/DOOR SCHEDULES FOR ADDITIONAL INFO REFER TO STRUCTURAL FOR FRAMING INFO ALL FLOOR TRANSITIONS SHALL BE AT CENTER OF DOOR, U.N.O. REFER TO ASSEMBLIES FOR WALL THICKNESSES AND FRAMING DIMENSIONS 1. 2. 3. 4. 5. 6. UPW/D HW D10720'-1 1/2" 5'-10 1/4" 16' 8'-1/4" 6'-10 1/4" 1 2'-1 1 " 7'-9 1/2" 20'-1 1/2" 51'-7"5'-1 1/2" 7'-1" 11'-4 3/4" 17'-3 1/4" 5' 5'-3 3/4"40'-9"36'-5"5 1/2"20'-6 1/4"1A-3011A-3013 A-302 3 A-302 2A-3012A-3012A-3012A-3011 A-201 2 A-201 2 A-202 1 A-202 1 A-203 3 A-203 2 A-203 COVERED PARKING SPOT #1 (10'X20') COVERED PARKING SPOT #2 (10'X20') PARKING SPOT #4 (10'X20') PARKING SPOT #3 (10'X20') BENCH 18" A.F.F. SLIDING DOOR TO GARAGE CLOSET LINE OF FLOOR ABOVE MECH ACCESS HATCH CLAD HATCH TO ACCESS STORAGE UNDER STAIR WOOD SCREEN W OPERABLE GLAZING IN COURTYARD PROVIDES PASSIVE COOLING AND VENTILATION WATER HEATER TANK WATER HEATER COMPRESSOR D104W1 03 D109D108 W1 0 1 D106D105 W1 02 D101 W1 04 GARAGE A: 405 sq ft GENKAN A: 50 sq ft FAMILY ROOM A: 159 sq ftMECH R 33 11 44 A A C C 22 E E F F 55 D D B B 7'-7 3/4" 10'-9 1/2"6 3/4"10'-9 1/2" 4'-5" 3'-6 1/2" 2'-6 3/4"7'-11 3/4" 6'-8 1/2"8'-6 1/4" 4'-4 3/4"20'-4 1/4"3 1/2"5'-10" 5'-3 3/4" 2' 6'-1/2"4' CLR3'-2 3/4" 9'-1 1/2" 3'-3 3/4" 3'-2" CLRORNAMENTAL GATE TO HOUSE BENCH STUCCO LANDSCAPE WALLS OPENING IN LANDSCAPE WALL RECESSED WOOD CLAD GARAGE DOOR OUTDOOR BBQ LINE OF AWNING ABOVE D102D103 LIVING A: 178 sq ft KITCHEN / DINING A: 238 sq ft BATH A: 42 sq ft HALL A: 48 sq ft N 0 2' 4' 8' SCALE: 1/4" = 1'-0" 1 LEVEL 1 FLOOR PLAN A-122 LEVEL 1 FLOOR PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano DN1A-3011A-3013 A-302 3 A-302 2A-3012A-3012A-3012A-3011 A-201 2 A-201 2 A-202 1 A-202 1 A-203 3 A-203 2 A-203 5'-1 1/4" 10'-10 3/4" 7'-1 1/4" 6'-8 1/4" 7'-1/4" 6'-3/4"2'-10 3/4" 3'-4 1/2" 7'-5 3/4" 2'-7 1/4"ABV REFER TO ELEV ABV REFER TO ELEV GUARDRAIL 47 SQFT STORAGE LOFT ABV LADDER TO STORAGE LOFT 47 SQFT STORAGE LOFT ABV LADDER TO STORAGE LOFT AWNING ABV, TYP D205 D206 W202 W206 D201D203 D202 D204W201 D207W205 W203W204 BATH A: 32 sq ft HALL A: 78 sq ftLANDING A: 42 sq ft 33 11 44 A A C C 22 E E F F 55 D D B B W2 1 3 W2 1 1 W2 1 2 2'-10 3/4" 2'-9" 3'-7 3/4" 6'-11 3/4"16'-4 1/4"5'-1 1/4" 10'-5 1/4" 8'-1/4" 4'-7" 4'-11 1/4" 3 1/2" 4'-11 1/4" 4'-7" 42'-10 1/2" ABV ABV REFER TO ELEV MECH CHASE ABV REFER TO ELEVW210 W209 W207 W208 POWDER A: 13 sq ft WET ROOM A: 35 sq ft MASTER BEDROOM A: 160 sq ft KID'S A: 94 sq ft KID'S A: 94 sq ft PLAN NOTES: ALL DIMS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. ALL INDICATED ALIGNMENTS ARE TO F.O. FINISH WINDOW OPENING DIMENSIONS ARE MEASURED FROM THE ROUGH OPENING - REFER TO WINDOW/DOOR SCHEDULES FOR ADDITIONAL INFO REFER TO STRUCTURAL FOR FRAMING INFO ALL FLOOR TRANSITIONS SHALL BE AT CENTER OF DOOR, U.N.O. REFER TO ASSEMBLIES FOR WALL THICKNESSES AND FRAMING DIMENSIONS 1. 2. 3. 4. 5. 6. N 02 02 02 02 02 02 02 02 0 2' 4' 8' SCALE: 1/4" = 1'-0" 1 LEVEL 2 FLOOR PLAN A-123 LEVEL 2 FLOOR PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano PLAN NOTES: ALL DIMS ARE TO FACE OF FRAMING OR FACE OF CONCRETE/BRICK U.N.O. ALL INDICATED ALIGNMENTS ARE TO F.O. FINISH WINDOW OPENING DIMENSIONS ARE MEASURED FROM THE ROUGH OPENING - REFER TO WINDOW/DOOR SCHEDULES FOR ADDITIONAL INFO REFER TO STRUCTURAL FOR FRAMING INFO ALL FLOOR TRANSITIONS SHALL BE AT CENTER OF DOOR, U.N.O. REFER TO ASSEMBLIES FOR WALL THICKNESSES AND FRAMING DIMENSIONS 1. 2. 3. 4. 5. 6. 1A-3011A-3013 A-302 3 A-302 2A-3012A-3012A-3012A-3011 A-201 2 A-201 2 A-202 1 A-202 1 A-203 3 A-203 2 A-203 7,450 kWh SOLAR ARRAY SKYLIGHT FOR PASSIVE VENTILATION AWNINGS, TYP 33 11 44 A A C C 22 E E F F 55 D D B B N 02 0 2' 4' 8' SCALE: 1/4" = 1'-0" 1 ROOF A-124 ROOF PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano P.L. A P.L.E C F D B 10'10'9'-6"NO PRIVACY SCREEN REQ'DPER CMC 19.28.120.A1b 3'25'-5"WINDOW SILL WINDOW SILL 25'-1 1/2"NATURAL GRADENATURAL GRADE 3'WINDOW SILL 9'-6"WINDOW SILL 3'WINDOW SILL 25° CONCRETE BENCH PRIVACY SCREENING PER 1 9.28.1 20 STUCCO WALL FRONT YARD TREE VERTICAL WOOD SIDING ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS STEEL AWNING BUILDING HEIGHT PRIOR TO REVISION 1 METAL CORNER PANEL STEEL AWNING, TYP. UPPER WINDOWS ARE FIXED, TYP. W2 1 3 W2 1 1 W2 1 0 W2 1 2 W2 09 25° P.L. 4 3 2 1 5 P.L.10'4'-6"WINDOW SILL 25'-2"3'WINDOW SILL PARAPET TO CONCEAL SOLAR ARRAY VERTICAL WOOD SIDING LIVING ROOM BYND ORNAMENTAL ENTRY GATE STUCCO LANDSCAPE WALL 25°25° STEEL AWNING 7,450 kWh SOLAR ARRAY ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 METAL CORNER PANEL STEEL AWNING WRAPS CORNER W2 02 W201 25'-5 3/4"10'NATURAL GRADE NATURAL GRADE CONCRETE BENCH INFILL PANEL FOR STREET NUMBER RECESSED WOOD PANELED GARAGE DOOR -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET 02 02 0 2' 4' 8'SCALE: 1/4" = 1'-0" 1 NORTH ELEVATION 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 EAST ELEVATION A-201 ELEVATIONS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano P.L. A C E P.L.D F B 10'10'24'-10 1/4"9'-6"NO PRIVACY SCREEN REQ'DPER CMC 19.28.120.A1b WINDOW SILL WINDOW SILL 8'NO PRIVACY SCREEN REQ'DPER CMC 19.28.120.A1b WINDOW SILL CONCRETE BENCH STUCCO WALL FRONT YARD TREE VERTICAL WOOD SIDING 25° 25° AWNING TO MINIMIZE SOLAR HEAT GAIN ON WEST FACING GLAZING STEEL AWNING ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 STEEL AWNING, TYP. W2 05 W2 06 W203 W2 04 26'NATURAL GRADE NATURAL GRADE3'1 2 3 4 5 P.L. P.L.10'10'25'-1/2"WINDOW SILL 25'-2"WINDOW SILL 25°25° VERTICAL WOOD SIDING PARAPET TO CONCEAL SOLAR ARRAY PLASTER SIDING AWNING TO MINIMIZE SOLAR HEAT GAIN ON WEST FACING GLAZING ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 STEEL AWNING, TYP. D102 W2 07 W1 04 D103 W208 NATURAL GRADE NATURAL GRADE3'9'-6"-3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET 02 02 0 2' 4' 8'SCALE: 1/4" = 1'-0" 1 SOUTH ELEVATION 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 WEST ELEVATION A-202 ELEVATIONS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 1 2 /1 6/2 01 9 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano P.L. A C D E F P.L.B 10'24'-10 1/4"9'-6"NO PRIVACY SCREEN REQ'DPER CMC 19.28.120.A1b WINDOW SILL WINDOW SILL WINDOW SILL 0' A.F.F WINDOW SILL 8'NO PRIVACY SCREEN REQ'DPER CMC 19.28.120.A1b GARAGE CONCRETE BENCH FRONT YARD TREE VERTICAL WOOD SIDING 25° 25° AWNING TO MINIMIZE SOLAR HEAT GAIN ON WEST FACING GLAZING STEEL AWNING WOOD SCREEN METAL INFILL PANEL ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 STEEL AWNING, TYP. W1 03 W2 05 W2 06 W2 03 W2 04 10'NATURAL GRADE NATURAL GRADE26'3'P.L. 5 4 3 2 1 P.L. 10'10'VERTICAL WOOD SIDING ENTRY BENCH GARAGE 25°25° STUCCO SIDING 7,450 kWh SOLAR ARRAY COVERED ENTRY ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 METAL CORNER PANEL W2 01 STEEL AWNING, TYP. LIVING ROOM BYND W2 0 2 W1 01 25'-5 1/2"NATURAL GRADE P.L. 5 4 3 2 1 P.L.10'10'VERTICAL WOOD SIDING HOUSE 25°25° PARAPET TO CONCEAL SOLAR ARRAY STUCCO SIDING 7,450 kWh SOLAR ARRAY SKTLIGHT FOR PASSIVE VENTILATION ALLOWABLE ENVELOPE PER SETBACK REQUIREMENTS BUILDING HEIGHT PRIOR TO REVISION 1 D104 25'-5 1/4"NATURAL GRADE -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET 02 02 02 0 2' 4' 8'SCALE: 1/4" = 1'-0" 1 SOUTH ELEVATION IN COURTYARD 0 2' 4' 8' SCALE: 1/4" = 1'-0" 2 EAST ELEVATION IN ENTRY 0 2' 4' 8' SCALE: 1/4" = 1'-0" 3 EAST ELEVATION IN COURTYARD A-203 ELEVATIONS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 1 2 /1 6/2 01 9 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano 1 3 4 2 5 MASTER BEDROOM LIVINGKITCHEN DINING SOLAR ARRAY STEEL AWNING, TYP. 1 2 3 4 5 7' CLR4'-8" CLRKID'S GARAGEFAMILY ROOM HALL EXTERIOR ENTRYWAY SOLAR ARRAY STEEL AWNING, TYP. SOLAR ARRAY KID'S STORAGE LOFT STEEL AWNING, TYP. STORAGE FALL PROTECTION -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET 1 2 3 4 5 MECH SOFFIT MECH ENTRY HALL WATER HEATER OPERABLE SKYLIGHT FOR PASSIVE VENTILATIONSOLAR ARRAY STEEL AWNING, TYP. WOOD SCREEN MECH CHASE -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET 02 02 02 SCALE: 1/4" = 1'-0" 1 SECTION A SCALE: 1/4" = 1'-0" 2 SECTION C SCALE: 1/4" = 1'-0" 2 SECTION B A-301 SECTIONS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano -3'-5" T.O. FOOTING ±0" LEVEL 1 F.F. +10'-2" LEVEL 2 F.F. +24'-8" T.O. PARAPET P.L. P.L.A E C F D B MASTER BEDROOM ENTRY LIVING BEYOND LANDING HALLBATHROOM MASTER BATH SLIDING DOOR TO GARAGE EXTERIOR ENTRYWAY ENTRY BENCH OPENING IN LANDSCAPE WALL MECHMECH STEEL AWNING, TYP. SKYLIGHT FOR PASSIVE VENTILATION 02 02 SCALE: 1/4" = 1'-0" 3 SECTION D A-302 SECTIONS SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano A_WALL EXT A_WALL INT A_WALL INT PARTITION TAG D101 D102 D103 D104 D107 D108 D109 D106 D201 D202 D203 D204 D205 D206 D207 D105 D106 MANUFACTURER --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- TYPE/MODEL UNIT SIZE HEIGHT (FT) 9'-5" 8'-9 1/2" 8'-9 1/2" 9'-1 1/2" 5'-10 3/4" 8' 6'-8" 6' 7' 7' 7' 7' 6'-10" 6'-10" 7' 8' 8' WIDTH (FT) 3'-6" 10'-5" 10'-5" 10'-5" 5'-2 1/2" 6' 3' 2'-8" 2'-8" 2'-6" 2'-6" 2'-8" 2'-8" 2'-8" 2'-8" 2'-6" 3'-2 1/2" THICK (IN) 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-2" 0'-1 3/4" 0'-1 3/4" 0'-1 1/2" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" 0'-1 3/4" DOOR OPERATION SWING SLIDER SLIDER SLIDER PIVOT BYPASS SWING POCKET POCKET SWING SWING POCKET SWING SWING POCKET POCKET POCKET FINISH PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 PT-1 HARDWARE HANDLE LOCK SCREEN --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- U-VALUE (GLAZ)NFRC# DOOR NOTES LEVEL LEVEL 1 F.F. LEVEL 2 F.F. TAG W101 W102 W103 W104 W201 W202 W203 W204 W205 W206 W207 W208 W209 W210 W211 W212 W213 MANUFACTURER MODEL OPERATION CSMT, OUT FIXED FIXED FIXED CSMT, OUT CSMT, OUT FIXED CSMT, OUT FIXED FIXED CSMT, OUT CSMT, OUT CSMT, OUT FIXED CSMT, OUT FIXED CSMT, OUT UNIT SIZE HEIGHT 9'-4" 9'-8 1/4" 8'-11 1/2" 9'-1" 4'-6" 3' 4' 1'-6" 4'-6" 2'-6" 4'-6" 2'-6" 1'-6" 2'-6" 4'-6" 2'-6" 4'-6" WIDTH 4'-3 3/4" 1'-9" 13'-7 1/2" 3'-6" 2'-6" 3' 6'-10 1/2" 1'-6" 6'-9" 9'-10" 2'-8" 2'-6" 1'-6" 9'-10" 4'-6" 2'-6" 4'-6" SCREEN --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- SAFETY GLAZING EGRESS E.G. E.G. E.G. E.G. E.G. E.G. E.G. NFRC# U-VALUE 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 SHGC 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 NOTES DOOR SCHEDULE WINDOW SCHEDULE EXTERIOR DOORS INTERIOR DOORS A-601 SCHEDULES SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano 1,024 sq ft 503 sq ft FRONTYARD IMPERVIOUS AREA FOR LOTS <60' WIDTH, MAXIMUM IMPERVIOUS AREA = 50% OF FRONT YARD AREA LOT WIDTH = 51' IMPERVIOUS AREA = 503 SQFT FRONT YARD AREA = 1,024 SQFT 503/1,024 = 49% OF FRONT YARD AREA IS IMPERVIOUS NEW PRIVACY PLANTINGS PER CUPERTINO LANDSCAPE REQ'M 19.28.120.C.2 SPECIES: CUPRESSUS SEMPERVIRENS - ITALIAN CYPRESS QUANTITY: 15 @ 2'8" O.C. SIZE: MIN 6' PLANTED HEIGHT, MIN 15-GALLON TURF AREA = 612 SQFT CRUSHED GRAVEL, TYP. PLANTING AREA = 566 SQFT, AT LEAST 80% OF NON-TURF AREA SHAL CONSIST OF NATIVE OR LOW WATER USE PLANTS PLANTING AREA = 107 SQFT, AT LEAST 80% OF NON-TURF AREA SHAL CONSIST OF NATIVE OR LOW WATER USE PLANTS CRUSHED GRAVEL, TYP. NEW PRIVACY PLANTINGS PER CUPERTINO LANDSCAPE REQ'M 19.28.120.C.2 SPECIES: CUPRESSUS SEMPERVIRENS - ITALIAN CYPRESS QUANTITY: 7 @ 2'8" O.C. SIZE: MIN 6' PLANTED HEIGHT, MIN 15-GALLON NEW PRIVACY PLANTINGS PER CUPERTINO LANDSCAPE REQ'M 19.28.120.C.2 SPECIES: PODOCARPUS GRACILIOR QUANTITY: 7 @ 6' O.C. SIZE: MIN 6' PLANTED HEIGHT, MIN 15-GALLON PLANTING AREA = 25 SQFT, AT LEAST 80% OF NON-TURF AREA SHAL CONSIST OF NATIVE OR LOW WATER USE PLANTS NEW FRONT YARD TREE PER CUPERTINO LANDSCAPE REQ'M 19.28.120.C.1 SPECIES: EUCALYPTUS POLYANTHEMOS - SILVERDOLLAR SIZE: MIN 24" BOX AND MIN 8' PLANTED HEIGHT30°30°30° 30°30° 30° COURTYARD 30° 30° 2ND STORY WINDOWS, TYP 30°30°NEW PUBLIC STREET TREE SPECIES: TILIA TOMENTOSA NEW PRIVACY PLANTINGS PER CUPERTINO LANDSCAPE REQ'M 19.28.120.C.2 SPECIES: MELALEUCA LINARIFOLIA - FLAXLEAF PAPERBARK SIZE: MIN 24" BOX AND MIN 8' PLANTED HEIGHT TURF AREA = 70 SQFT 18 TALL CONCRETE BENCH CONCRETE PAVER, TYPICAL 18 TALL CONCRETE BENCH CONCRETE PATIO 30°30°10379 MENHART LANE (E) SINGLE FAMILY RESIDENCE 10391 MENHART LANE (E) SINGLE FAMILY RESIDENCE 10385 MENHART LANE (N) SINGLE FAMILY RESIDENCE ZONING R1-5 GARAGE LANDSCAPE AREA 2,327 SQFT IF LESS THAN 2,500 SQFT PRESCRIPTIVE COMPLIANCE APPLICATION IS REQUIRED 2,327 sq ft 02 02 02 0 8' 16' 32' SCALE: 1/16" = 1'-0" 2 FRONTYARD IMPERVIOUS AREA 0 4' 8' 12'SCALE: 3/16" = 1'-0" 1 PRELIM LANDSCAPE PLAN 0 8' 16' 32'SCALE: 1/16" = 1'-0" 3 LANDSCAPE AREA L-101 CONCEPTUAL LANDSCAPE PLAN SHED ARCHITECTURE & DESIGN 1401 S JACKSON ST SEATTLE, WA 98144 206.320.8700 PROJECT DRAWING TITLE ISSUE DATE CONTACT CHEN NOT FOR CONSTRUCTION 10385 MENHART LANE CUPERTINO, CA 95014 © SHED ARCHITECTURE & DESIGN SEATTLE, WA 98144 12/16/2019 1:33 PM06/24/2019 07/24/2019 10/28/2019 12/16/2019 PRELIMINARY REVIEW RESIDENTIAL DESIGN REVIEW DESIGN REVIEW REVISION 1 DESIGN REVIEW REVISION 2 01 02 R-2019-016 01/29/20 Erick Serrano R-2019-016 01/29/20 Erick Serrano