Loading...
B-2016-1626 (2)CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building a()cupertino.org PROJECT ADDRES& 0205 VICKSBURG DR APN# 36907009 OWNERNAME KENNETH KHO PHONE 408 568-4306 E-MArt, STREET ADDRESS 10205 VICKSBURG DR CITY, STATE, ZIP CUPERTINO, CA 95014 7 FAX CONTACT NAME Kristi Cassetta PHONE831-226-9363 E-MAIL kcassetta@sandbarsc.com STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 FAX 1 831-515-5098 ❑ OWNER ❑ OWNER -BUILDER ❑ OWNER AGENT IX CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT ❑ ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Sandbar LICENSE NUMBER 846294 LICENSE TYPE C-10 BUS. LIC # �? J3�25 `9 nGaYerAu Westside Electric dba Sandbar E-MAIL sandbarsc.com AX F 831-515-5098 STREET ADDRESS 2119 Delaware Avenue CITY, STATE, ZIP Santa Cruz Ca 95060 PHONE 831-469-8888 ARCHITECT/ENGINEER NAME Sungevity LICENSE NUMBER BUS. LIC # COMPANY NAME E-MAIL Sam - sholing@sungevity.com FAX STREET ADDRESS 66 Franklin Street Ste. 310 CITY, STATE ZIP Oakland CA 94607 PHONE" USE OF XI SFD or Duplex ❑ Multi -Family STRUCTURE: ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes NO PROJECT IN FLOOD ZONE ❑ Yes ❑ NO IX SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: 'i 0 KILOWATTS (COMMERCIAL ONLY): 5. _72 TOTAL VALUATION: 21 000 DESCRIPTION OF WORK Installatio of a 6kw grid tied photovoltaic solar array roof mount CEIVED B �• By my signature below, I certify to a of a following: I am the property owner or authorized agent to act on the perty owner' eha ave read this application and the information I ha ovi ed i co ct. I have read the Description of Work and verify it is accurate. I a y with all applicable local ordinances and state laws relatin buil in cc s ion. I authorize representatives of Cupertino to enter the above-identi Ie property for inspection purposes. Signature of Applicant/Agent: Date: PLEMENTAL INFORMATION REQUIRED of ICE USE ONLY �R THE -COUNTER , ❑ EXPRESS . UW M ' ' .❑ " STANDARD U :❑ LARGE "MAJOR PVApp_2011.d6c revised 03116111 i PH OTOVOLT AIC SYSTEM SYSTEM SIZE: AC / DC kW STC: 5.324kW \ 6kW EQUIPMENT: \ t-z PV MODULES: (20) LG LG300N1K-G4INVERTER(S): (1) SolarEdge SE6000A-US SCOPE OF WORK: INSTALLATION OF A SAFE AND CODE -COMPLIANT GRID -TIED SOLAR PV SYSTEM ON AN EXISTING RESIDENTIAL ROOF TOP. APN: 36907009 C. mt,, "' 1PII I Y DEVELOPMENT DEPARTMENT BULG;NG DIVISION - CUPERTINO This —.F of �,,nd spo ifications MUST be kept at the It is unlawful to (make any xis on same, or to deviate ac.roval from the Building Official. cf th;s plan and specifications SHALL NOT or to be an approval of the violation c„ I5 or a lihance or State Law. P C'llJill NO. sunGEVITY° GENERATE POSITIVE' ZO PLAT- PLANS CHECKED B DATE PLA NIN ®EPT CUPERTINO 11 SUNGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND. CA W07 ROOF MOUNTED CONDUIT (TYP.) C CI SITE PLAN N SCALE: N.T.S. OFFICE: 0,0PY SHEET INDEX PV0.0 COVER AND SITE PLAN PV1.0 GENERAL NOTES PV2.0 - 2.1 ARRAY LAYOUT PV3.0 LINE DIAGRAM PV4.0 LABELS KEY: ---- PROPERTY LINE — — — CONDUIT RUN Q INVERTER DRIVEWAY s. SUBPANEL FENCE DC DISCONNECT FIRE CLEARANCE AC DISCONNECT o STRUCTURAL c UPGRADES JUNCTION BOX SOLAR MODULE El MONITORING UNIT MAIN MAIN SERVICE PANEL 0 COMBINER BOX Q UTILITY METER ROOF wM PV METER OBSTRUCTION APPLICABLE CODES: 2013 CEC (BASED ON 2011 NEC) 2013 CBC 2013 CRC 2013 CPC 2013 CMC 2013 CFC LOCAL AMENDMENTS TO CA CODES CONTRACTOR INFORMATION: E SANDBAR SAN JOSE 2119 DELAWARE AVE SANTA CRUZ, CA 95060 JURISDICTIONAL INFORMATION: J/ CUPERTINO, CITY OF Y 10300 TORRE AVENUE CUPERTINO, CA 95014 MP 711 �qe jz �p OTES TO INSTALLER: O "F� gOe N Ci1Tl[3UIT FROM AC DISCO TO MSP THROUGH THE WALL FQ/yjVW SPACE IF POSSIBLE. CO�',p �. �OR INSTALLER USE ONLY �. CIO POST INSTALL SUN EYES REQUIRED? NO V I CERTIFY THAT NO CHANGES HAVE C BEEN MADE TO THE ARRAY LAYOUT: CUSTOMER INFORMATION: 1 v KENNETH KHO 10205 VICKSBURG DR CUPERTINO, CA 95014 (408) 568-4306 / #1968869 LW �e ' ` 4 DESIGNED BY: IREV #:I DATE: RK I 0 3/23/16 By: NSHOOP-COHEN Date. Location: Kho - 1968869 SV2 Sheet Size: 11x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and 705.10 N10. INSTALLER TO FOLLOW ALL LOCAL JURISDICTION GUIDELINES. N11. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC REFERENCES. N12. IT IS ILLEGAL FOR ANYONE UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFFESIONAL ENGINEER OR REGISTERED ARCHITECTTO ALTER ANY ITEMS ON THIS PLAN. N13. THE ENGINEER HAS NOT BEEN RETAINED FOR JOB SUPERVISION. N.14 ALL OSHA REGULATIONS AND STANDARDS FOR SAFE AND HEALTHFUL WORKING CONDITIONS TO BE FOLLOWED. N.15 ALL CONTRACTORS WORKING ON ROOFS TO BE INSURED AS SUCH. STRUCTURAL NOTES: S1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE, BUT SHALL BE ACCURATELY SPACED. S2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE LOAD AMONGST RAFTERS. S3. DO NOT SPLICE RAILS IN MIDDLE 50% OF SPAN BETWEEN TWO MOUNTS. 4e sunGEVITY° GENERATE POSITIVE' E1. ALL EQUIPMENT IS LISTED FOR USE. E2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. E3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY. E4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUTTO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTILTHE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. E5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. E6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT CALCULATED ATTHAT COMPONENT. E7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL BE PROPERLY GROUNDED. E8. DC EQUIPMENT SHALL BE 60OVDC RATED MINIMUM. E9. MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. E10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE JURISDICTIONAL REQUIREMENTS. E11. FOR ANY UNGROUNDED PV SYSTEM, A LABEL READING: "WARNING - ELECTRICAL SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." SHALL BE PLACED AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. E12. INVERTER(S) SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION DEVICE. E13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. E14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CEC/NEC. E15. BACKFED SOLAR BREAKER(S) SHALL BE INSTALLED AT THE OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER. E16. ALL WIRE, VOLTAGES, AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO TEMPERATURE DERATING AND LOCATION. E17. ONLY COPPER (CU) CONDUCTORS SHALL BE USED. CONDUCTORS SHALL BE STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. E18. DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED E19. ALL MODULES AND RACKING SHALL BE GROUNDED VIA IRON RIDGE RAIL INTEGRATED GROUNDING (PLEASE SEE DATA SHEET) OR WITH TIN PLATED DIRECT BURIAL RATED LAY IN LUGS USING STAINLESS STEEL HARDWARE, STAR WASHERS, AND THREAD FORMING BOLTS. E20. ALL EQUIPMENT SHALL BE GROUNDED, INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF RAIL. a '9(a di "INC)CUPER it �9 DU •'�de39i �e '�o9d�, REV1 FINED Fop CO RevieWea ey. DE CO, d "PUTANCE oy. -- I... -1.. 1- - m..... ova .1-1 o.- 1 is 11 1 ne a UKAVVINUJ, bVtUI IUPJ 1--, ANU Ut51GNS ARE THE PROPERTY OF SUNGEVITY INC. NO PAR I SHALL BE COPIED OR USEU FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT I G� 1 1 16'-2" 14L Ge 4:� Lml RR AY �s� ���aN '-0" NOTE: MODULES SHALL NOT BE GREATER INCHES ABOVE ROOF COVERING SOLAR MOD IRONRIDGE � L-FI QMSE-LAG SHIN COMPOSITE SHIN 5" X 5/16" - 2.5" MIN. EMBEDMENT SCF 2X4 NOMINAL, 24 MOUNTING DETAIL 2 SCALE: NTS sunGEVITY` GENERATE POSITIVE' 11 14 a MODULE SPECIFICATIONS (20) LG LG300N1K-G4 MODULE WEIGHT: 37.48 MODULE LENGTH: 64.57 MODULE WIDTH: 39.37 ROOF 1SPECS RAFTER SIZE: 2X4 NOMINAL RAFTER SPAN: 7' - 1" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 1SPECS NUMBER OF MODULES: 12 TOTAL MOD. WEIGHT (Ibs): 449.8 A RACKING WEIGHT (Ibs): 83.7 ARRAY WEIGHT (Ibs): 533.4 ARRAY AREA (sqft): 211.8 ARRAY DEAD LOAD (Ibs/sgft): 2.5 NUMBER OF MOUNTS: 33 LOAD PER MOUNT(Ibs): 16.2 ARRAY AZIMUTH(') 197 ARRAY TILT(-) 21 NUMBER OF FLOORS 1 ROOF 1 SECTION SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE .............® STRING CONFIG. STRUCTURAL UPGRADES E SOLAR MODULE ® MOUNT ® SKYLIGHT ® CHIMNEY PLUMBING OR o ATTIC VENT ID ATTIC VENT CLJPE `-r1�40 Uwilding De .crr. ;r� joat,,017, e4F�$U FOB CODES CCo"VIPLIANCS pd B y. C CUSTOMER INFORMATION: KENNETH KHO 10205 VICKSBURG DR CUPERTINO, CA 95014 (408) 568-4306 / #1968869 DESIGNED BY: REV #: DATE: PV- 2.0 RK 0 3/23/16 JGEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: NSHOOP-COHEN Date: Location: Kho-1968869 SV2 Sheet Size: 1 tx17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSE a I I I I I I I I! I I I I I I I I I I I I I I I I I I 1 I 1 1 ! ! 11 1 0 1 1! 1 11 1 1 1 1 I I I I I I l l l I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1.0 1 1 1 1 I I I I I I I I I I I 3 NOTE: MODULES SHALL NOT BE GREATER THAN 8 INCHES ABOVE ROOF COVERING sunGEVITY° GENERATE POEITIVE- 11 1 13'-2" I I I I I I I I I iROOF12 1 ARRAY 21 1 1 ARRAY 2 LAYOUT 1 17'-10" 1 01 of 0 1 47 I I I I I I I I I I I I I I I I I I 101 1 1 1 01 1 1 I I I I I I I I ROOF 2 SECTION Z) MODULE SPECIFICATIONS (20) LG LG300N1K-G4 MODULE WEIGHT: 37.48 MODULE LENGTH: 64.57 MODULE WIDTH: 39.37 ROOF 2 SPECS RAFTER SIZE: 2X4 NOMINAL RAFTER SPAN: 7' - 7" RAFTER SPACING: 24" ROOF MATERIAL: COMPOSITE SHINGLE ARRAY 2 SPECS NUMBER OF MODULES: 8 TOTAL MOD. WEIGHT (Ibs): 299.8 p RACKING WEIGHT (Ibs): 32.5 ARRAY WEIGHT (Ibs): 332.3 ARRAY AREA (sqft): 141.2 ARRAY DEAD LOAD (Ibs/sgft): 2.4 NUMBER OF MOUNTS: 12 LOAD PER MOUNT(Ibs): 27.7 ARRAY AZIMUTH(') 287 ARRAY TILT(-) 19 NUMBER OF FLOORS 1 SYMBOL KEY: ------- RAIL — — — — RAFTERS ROOF FIRE CLEARANCE .............® STRING CONFIG. ,,. STRUCTURAL UPGRADES E C3 SOLAR MODULE ® MOUNT ® SKYLIGHT ® CHIMNEY PLUMBING OR o ATTIC VENT 0 ATTIC VENT m . • 4 `f Building (�A�jcartfrient k REVIEWED FOR CODE COfVIF 0,4,yCE Reviewed By. C CUSTOMER INFORMATION: KENNETH KHO 10205 VICKSBURG DR CUPERTINO, CA 95014 (408) 568-4306 / #1968869 DESIGNED BY: REV #: DATE: RK 0 1 3/23/16 PV- 2.1 UUMV1I T IN6.6ti t-RANKUN S I SUITE 310 OAKLAND, CA 94607 6y: NSHOUI•-UUHCIV Uate:— Location: Kho-1966669 SV2 Sheet Size: 11x17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSE ELECTRICAL KEY: ft BREAKER -/.- SWITCH 0 SCREW TERMINAL FUSE • SPLICE EARTH GROUND M CHASSIS GROUND — — — GEC EGC an :l■ L (4) #10 PV-Wire (1) #10 EGC FREE AIR .��.._.1 STRING 8 MODULES "romm STRING_ ©J 12 MODULES������I •-CURRENT0 .. uu u le sunGEVITY- GENERATE POSITIVE' (4) #10 THWN-2 (1) #10 EGC 3/4" EMT (IF APPLICABLE) MIN. NEMA3R UL LISTED JUNCTION BOX WITH 90°C TERMINAL RATINGS LOCATED ON ROOF Inom = (12 x 300W)/350V = 10.3A OPERATING VOLTAGE = 350VDC (REGULATED) 200 x 1.2 = 240 240 - 200(MCB) = 40A MAX ALLOWABLE AC PV BREAKER = 40A ra ■ (3) #8 THWN-2 (1) #8 GEC 3/4" EMT (N) SE6000A-US INVERTER W/ INTEGRATED DC DISCONNECTS MPPT 1 AC DC .. OUTPUT -------- GEC -- MPPT 2 INVERTER ■ (3) #8 THWN-2 (1) #8 GEC 3/4" EMT N ■ (20) LG LG300NiK-G4 SOLAREDGE SE6000A-US SHORT CIRCUIT CURRENT (Isc): 9.7 RATED WATTS (EACH): 6000 OPEN CIRCUIT VOLTAGE (Voc): 39.7 AC OPERATING VOLTAGE (V): 240 OPERATING CURRENT (IMP): 9.26 AC OPERATING CURRENT (A): 25 OPERATING VOLTAGE (VMP): 32.5 NUMBER OF MPPT CHANNELS 0 MAX SERIES FUSE RATING: 20 INVERTER EFFICIENCY: 0.975 STC RATING: 300 INTEGRATED DC DISCONNECT PTC RATING: 273 INVERTER 1 INPUT SPECIFICATIONS DESIGN CONDITIONS NOMINAL CURRENT PER STRING (Inom): 6.9, 10.3 HIGHEST 2% DB DESIGN TEMP (°C): 32 NOMINAL VOLTAGE (Vnom): 350 MIN. MEAN EXTREME ANNUAL DB (°C): 0 MAX SYSTEM VOLTAGE (Vmax): 500 MAX CURRENT PER STRING (Imax): 15 P 30 MAX INPUT CIRCUIT CURRENT (Imax): LOCUS METER CONDUIT ELEVATION: 1/2 TO 3-1/2" = 22 °C HIGH AMBIENT TEMPERATURE: 32 °C EXTREME LOW: 0°C ROOFTOP AMBIENT TEMP (Tcorr): 540C = 0.76 CONDUIT FILL (Cfill): 0.8 CONTINUOUS USE = Imax * 1.25 = 15A CONDITIONS OF USE = Imax / Tcorr / Cfill = 15A/0.76/0.8 = 24.67A CONDUCTOR SIZE FOR 24.67A INSTALLATION SHALL USE MIN. #10 AWG (3) #8 THWN-2 (1) #8 GEC 3/4" EMT AC DISCONNECT, 60AMP, NON -FUSIBLE, C-H DG222URB 200A MAIN BREAKER METER (E) LOADS (E) LOADS (E) 200A Siemens MSP 35A 2P 240V 2P 3-W 1 I I I GEC IRREVERSIBLY SPLICED TO EXISTING GEC OR BONDED DIRECTLY TO EXISTING GROUNDING ELECTRODE CUPERTINO t3Wilding CePartn ent ou REVIEWED FOR CODE COMPLIANCE Reviewed 8y. 20 MODULES TOTAL 20 x 273(PTC WATTS) x 0.975 = 5324 CEC WATTS SE6000A-US MAX OUTPUT CURRENT = 25A BREAKER SIZE = 25A x 1.25 = 31.25A => 35A CUSTOMER INFORMATION: KENNETH KHO 10205 VICKSBURG DR CUPERTINO, CA 95014 (408) 568-4306 / #1968869 ■C ■C DESIGNED BY: REV #: DATE: PV- 3.0 RK 0 3/23/16 UNUEVITY INC. 66 FRANKLIN ST SUITE 310 OAKLAND, CA 94607 By: NSHOOP-COHEN Date:— Location: Kho-1968869 SV2 Sheet Size: 11x17 THESE DRAWINGS, SPECIFICATIONS, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USED FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSEN G J 4 5 NEC 690.5(c) PLACE THIS LABEL ON INVERTER(S) OR NEAR GROUND -FAULT INDICATOR (ON INVERTER(S) U.O.N.) WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED NEC 690.17(E) PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 705.12(D)(2)(b) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND SUBPANEL IF APPLICABLE)) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE NEC 705.12(D)(3) PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES. CAUTION CONTAINS MULTIPLE POWER SOURCES sunGEVITY° GENERATE POSITIVE" NEC 690.31 (E) 3 & 4; 2012 1 FC 605.11.1 PLACE ON ALL JUNCTION BOXES, EXPOSED RACEWAYS EVERY 10' AND 1' FROM BENDS AND PENETRATIONS, ADJACENT TO THE MAIN SERVICE DISCONNECT WARNING PHOTOVOLTAIC POWER SOURCE NEC 690.35(F) PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED INTERACTIVE PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT (A): 25. NOMINAL OPERATING AC VOLTAGE (V): 240 INVERTER 1 DC DISCONNECT PHOTOVOLTAIC SYSTEM DISCONNECT RATED MAX POWER POINT CURRENT (Imp): 17.1 RATED MAX POWER POINT VOLTAGE (Vmp): 350 MAX SYSTEM VOLTAGE (Voc): 500 SHORT CIRCUIT CURRENT (Isc): 12.1 oy. ­n­-wn­ nno - i oowo Sv1 Sneet Size: t txt i I MCOC DRAWINGS, SPtCIf ICA I IUNJ, AND DESIGNS ARE THE PROPERTY OF SUNGEVITY INC. NO PART SHALL BE COPIED OR USEU FOR OR WITH ANY OTHER WORK OTHER THAN THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN DEVELOPED WITHOUT OUR WRITTEN CONSENT U Life's ( LG's new module, NeONT"" 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires CAPPROVED PRODUCT to enhance power output and reliability. NeONTM 2 Black y i 60 celldemonstrates LG's efforts to increase customer's values B E °S ",cs beyond efficiency. It features enhanced warranty, durability, Intertek M-1564573 8S EN 61215 performance under real environment, and aesthetic design photaealtaf Mr&les suitable for roofs. Enhanced Performance Warranty LG NEONT"' 2 has an enhanced performance warranty. The annual degradation has fallen from-0.7%/yr to -0.6%/yr. Even after 25 years, the cell guarantees 2.4%p more output than the previous NeONT'" modules. Aesthetic hoof �® LG NeONT" 2 has been designed with aesthetics in mind; thinner wires that appear all black at a distance. The product may increase the value of a property with its modern design. ®e Better Performance on a Sunny Day LG NeONT" 2 now performs better on sunny days thanks to its improved temperature coefficiency. About LG Electronics so High Power Output Compared with previous models, the LG NeONT' 2 has been designed to significantly enhance its output efficiency, thereby making it efficient even in limited space. OOutstanding Durability With its newly reinforced frame design, LG has extended the warranty of the NeONT" 2 for an additional 2 years. Additionally, LG NeONT" 2 can endure a front load up to 6000 Pa, and a rear load up to 5400 Pa. 1 h Double -Sided Cell Structure The rear of the cell used in LG NeONTm 2 will contribute to generation, just like the front; the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. LG Electronics is a global player who has been committed to expanding its capacity, based on solar energy business as its future growth engine. We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi -conductor, LCD, chemistry, and materials industry. We successfully released the first Mono X® series to the market in 2010, which were exported to 32 countries in the following 2 years, thereafter. In 2013, NeONT'" (previously known as Mono X® NeON) won "Intersolar Award, which proved LG is the leader of innovation in the industry. LG`■; BlockLG300NtK-G4 Mechanical Properties Cells 6 x 10 Cell Vendor LG Cell Type Monocrystalline / N-type Cell Dimensions 156.75 x 156.75 mm / 6 x 6 inch u of Busbar 12 (Multi Wire Busbar) Dimensions (L x W x H) 1640 x 1000 x 40 mm 64.57 x 39.37 x 1.57 inch Front Load 6000 Pa / 125 psf t Rear Load 5400 Pa / 113 psf Weight 17.0 ± 0.5 kg / 37.48 ± 1.1 lbs Connector Type MC4, MC4 Compatible, IP67 Junction Box IP67 with 3 Bypass Diodes Length of Cables 2 x 1000 ram / 2 x 39.37 inch Glass High Transmission Tempered Glass Frame Anodized Aluminum Certifications and Warranty Certifications (In Progress) IEC 61215, IEC 61730-1 /-2, UL 1703, ISO 9001, IEC 62716 (Ammonia Test), IEC 61701(Salt Mist Corrosion Test) Module Fire Performance Type 2 (UL 1703) Product Warranty 12 years Output warranty of Pmax Linear warranty* (measurement Tolerance ± 3%) ' 1) 1 sty- 98%, 2) After 2nd year 0.6%p annual degradation, 3) 83.6%for 25 years Temperature Coefficients NOCT 46 ± 3 °C Pmpp -0.38 %/°C voc -0.28 %/°C Isc 0.02 %/°C Characteristic Curves 100ow ,o.o0 e.ao a0ow 600W 6.00 40OW 4.00 200Wy 2.00 -__..._.. r ` Voltage (v) 0.00 5.00 Moo 15.00 20.00 25.00 30.00 35.00 40.00 45.00 X 140 y 120 100 60 60 qo 20 0 _......... _ -----..-.... ..-. .._ ............._.............. _..._.........__._.___._.._pmaa _. A0 -25 0 25 50 75 90 North America Solar Business Team LG LG Electronics U.S.A. Inc Life% Good 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact lg.solar@tge.com www.Igsolarusa.com Temperature (°C) Electrical Properties (STC * 300 W MPP Voltage (Vmpp) 32.5 MPP Current (Impp) 9.26 Open Circuit Voltage (Voc) 39.7 Short Circuit Current (Isc) 9.70 Module Efficiency (%) 18.3 Operating Temperature (DC) -40 - +90 Maximum System Voltage (V) 1000 Maximum Series Fuse Rating (A) 20 Power Tolerance (%) 0 - +3 `STC (Standard Test Candition): Irradiance 1000 W/m', Module Temperature 25 eC, AM 1.5 ' The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. "The typical change in module efficiency at 200 W/m' in relation to 1000 W/m' is -3.0%. Electrical Properties (NOCT*) 300 W Maximum Power (Pmpp) 218 MPP Voltage (Vmpp) 29.5 MPP Current (Impp) 7.38 Open Circuit Voltage (Voc) 36.5 Short Circuit Current (Isc) 7.83 . NOCT (Nominal Operating Cell Temperature): Irradiance 800 W/m2, ambient temperature 20 aC, wind speed 1 m/s Dimensions (mm/in) aDID�9 FL Dead% Dea11Y Deai12 Um ode fi-une STort tide flame "The distance between the center of the mounting/grounding holes. Product specifications are subject notice. DS-N2-60-K-G-F-EN-50427'• E_1 Copyright © 2015 LG Electronics I- 01 /04/201 s i UPE \T11 Fl ar' im] flIIciIa e e fl Innovatio io ra e e S 1 t 1 an Id REVIEWED FOR CODE COMPLIAINCE Reviewed By: AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing i Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is riot transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: LG Electronics Inc. Manufacturer: LG Electronics Inc. 168, Suchul-daero, Solar Business 168, Suchul-daero, Solar Business Address: Division (Solar Factory), Gumi-si, Address: Division (Solar Factory), Gumi-si, Gyeongsangbuk-do 730-903, Republic Gyeongsangbuk-do 730-903, Republic of of Korea Korea Country: Republic of Korea Country: Republic of Korea Contact: Mr. Jeongwon Choi Contact: Mr. Jeongwon Choi Phone: +82-54-4690386 Phone: +82-54-4690386 FAX: +82-54-4607931 FAX: +82-54-4607931 Email: jeongwon7.choi@lge.com Email: jeongwon7.choi@Ige.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Intertek Testing Services Shanghai Control Number: 5000343 Authorized by: 1 Thomas J. tter­, C rtificaq& Manager US Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client Intertek's responsibility and liability are firnited to the tems and conditions of the agreement Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark_ only the Client is authorized to penrdt copying or distribution of this Authorization to Mark and then only in its entirety_ use of lntertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service rriust first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respell Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL 1703 2002/03/15 Ed:3 Rev:2014/11/18 UL Standard for Safety Flat -Plate Photovoltaic Modules and Panels Product: Crystalline Silicon Photovoltaic modules Brand Name: 0LG ElectrAomics LGxxxN 1 C-G4 ('xxx' is the number from 280 to 340, in step of 5), LGxxxN1 W-G4 ('xxx' is the number from 280 to 340, in step of 5), Models: LGxxxS1C-G4 ('xxx' is the number from 250 to 300, in step of 5), LGxxxS1 W-G4 ('xxx' is the number from 250 to 300, in step of 5), LGxxxN1 K-G4 ('xxx' is the number from 280 to 330, in step of 5). ATM for Report 150201020SHA-001 Page 1 of 1 ATM Issued: 28-Apr-2015 ED 16.3.15 (1-Jan-13) iNandatory Mechanical Installation Mounting Methods General Information • Select the appropriate orientation to maximize sunlight exposure. • Module should not be mounted or stored in a way that the front/top glass faces downward in order to prevent water from entering the junction box, which could cause a safety hazard. • Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module. The recommended standoff height is a minimum of 100mm. • When installed on a roof, the solar module must be mounted over a fire-resistant roof covering rated for the application. The fire resistance of the solar module is class C after ANSI/UL790. • A slope less than 5in/ft is required to maintain a fire class rating. • The solar module is only IEC listed for use when its factory frame is fully intact. • Removal or alteration must be done by an authorized and qualified individual • Creating additional mounting holes may damage the solar module and reduce the strength of the frame. • We recommend a 6mm gap between module frames to avoid tension from thermal expansion. • The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions. • The module is considered to be in compliance with UL1703 only when the module in mounted in the manner specified by the mounting instructions below. • The solar module may be mounted by using the following methods: (*Torque:8-12Nm ) • When installing modules in heavy snow areas, special care should be taken to install the modules in a manner that provides sufficient design strength while meeting local code requirements. • LG modules (Fire performance: Type 2) shall be mounted with racking and mounting products certified and listed for system fire class rating in accordance with UL1703 edition 2014 and UL2703 edition 2014. • It is recommended to check with local authorities for fire safety guidelines and requirements for any building or structure on to which the panels will be installed. Mounting by using frame bolts holes • Secure the solar module to the structure by using the factory mounting holes. • Four M6 stainless steel bolts, four nuts, four spring washers, and eight flat washers are recommended per solar module. • For rear loads 5400Pa, modules should be fastened with four M8 stainless steel bolts, four nuts, four spring washers, and eight flat washers. • The module may be fastened to a support by using both the outer and inner bolt holes of the frame. • Each module should be securely fastened at a minimum 4 points on two opposite sides. • Specific information on the solar module dimensions and location of mounting holes is provided in 'Product Specifications'. Module frame Bolt Flat washer Flat washer Spring washer Nut Support • Tighten the bolt securely by using the combination shown above. Place the spring washer between the Flat washer and Nut. Mounting by using clamps • The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules. Specific information on location of clipping is provided in 'Mechanical Installation Scene'. (Refer to next page) 0 enx More it�a�t/IETTED FOR CODE COMPL1AVCE Reviewed By. - s o I a r �'W'__ SolarEdge Single Phase Inverters For North America SE3000A-US SE380OA-US / SE5000A-US / SE6000A-US SE760OA-US SE1000OA-US / SEI 140OA-US USA -GERMANY -ITALY -FRANCE -JAPAN -CHINA -AUSTRALIA -THE NETHERLANDS -UK -ISRAEL www.solaredge.us Single Phase Inverters North America solar =es SE3000A-US SE380OA-US / SE5000A-US / SE6000A-US SE760OA-US SE1000OA-US / SE1140OA-US SE30 OA -US SE3800ALUS I 'SE5000A-U5 :1 SE6000A-US.j.$E7606A-IJS I SE10060A=LIS I SE11400A-US- OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ...... ................ ...... ..1.00.010.(_@240V. .............. .......... Max. AC Power Output 3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000 VA ... ­ I .... I ... I ............. ............. ... ...... ... ......... . .......... I ..... ................10950 240V. .................. ........... AC Output Voltage Min.-Nom.-Max.11) AC Output Voltage Min.-Nom.-Max.(Ii V ..... V .............. ........ ..21.1.-.24.07.26.4.Vac .................... AC Frequency . . . . I ..... ................ ...... ...... ......... ...... ........ .............. ... 59.3 - 60 - 60.5 I ....... Hz Output . I . Max. Continuous Current 12.5 I I 24'6'268v 25 ... ....... 32 ....... 496 268'v ... 47.S A .............................. ................ ....... ................ ... ...4. 2 (�. ...... GFDI * Threshold , , * ­ ...... * .11 .......... 1.1 ...... I., ........ I .......... I ........ I ............... ............................................................ Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes .... Yes INRUT,'7,, JMaximum DC Power(STC) '''*'''''U'ngro'und*ed... 4050 5100......6750 8100 1OZ50 13500 15350 W Transformer -less, 1.­I....................... Yes ...... ..... ........ ...... .... ..... J��x.Input Voltage ...... ...... ....... .. ....... ........................ ........ .50,0 .......... ....................... ................ ......... Vdc ..N.om.. DCInputVoltage ................. ................ .325 @.208V / 350 @ 240V -is ....... ... .... Vdc Max. Input Current(" 9.5 1 23 33'& ........ 34.5 ........... Adc ...... ... 30.5 ,@, .. ..... ... Input put Short 'Circuit'C 'u rrent ....... ' ' ................................................ .....4.5 ............................................................ Adc Reye�-�plarit Protection ..Reverse-Polarity .. .. . .... ..-....I......................................... ................. ................................................ Yes ... ..Ground -Fault Isolation Detection ...... 'lnv'rt 600k.Q Sensitivity ........................................ .... * ...... Maximum e*er'E'ffici*'nc .......... ..... 98 CEC Weighted Efficiency 97.5 98 97 @ 208V97.5 ......... 97.5 97 @ 208V 97.5 % .......... ... ... ........ ­98.0). 240y ; ............... Nighttime Power Consumption < 2.5 < 4 W Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) ........... * , , , " * " * , , * .............. * .......... .. ..... Revenue ..G, ra..d. e.. Data, ...... ..................... Optional0i ........................ ................. ......................... . Rapid Shutdown — NEC 2014 690.12 Yes ..STANDARD'CdMPLIANCE' Safety . Grid 'Co9.R..�p����ndards...... .......... .. . . .......I...... Emissions ......................................... UL.1.74.1, U.L16,99.B,..UL1.998.,.CSA.22..2 ...... ..................... ............ IEEE1 47 .............. ....... ...........p..... . I ........ .......... ........... ..................... FCCar15 class B ........... ... INSTALLATION SPECIFICATIONS ..AC outp.u.t. conduit .size / A%YG range 3/4" minimum 16-6 AWG 3/4" minimum 8- DC input conduit size /# of strings/ minimum / 1-2 strings / 16-6 AWG ............... 3/4; mini��'ri* */1'-'3 strings / ..AWG ran Kq I , I * 1. ............. .......................................... ........................... b.............. Dimensions with Safety Switch ....... 30.5 x 12.5 x 7.2 / 775 x 315 x 184 ............ ...... 30.5 x 12.5 x 10.5 in/ JHxMp) ... I ................. .... ... ...... ...... ......................... ... ..... T75.x 45 ?� 260. . ........ ... T R, .... Weight with Safety Switch ............ I ............................... 51.2/23.2 54.7/24.7 ................................ ...................... ­ ....... I .. .... , .... 88.4/40.1 ................................. lb/ kg ...... �atur a I convection Cooling Natural Convection and internal Fans (user replaceable) fan (user ........... ............. ­­­* .... Noise < 25 .......................... Min.-Max. Ran a-13 to +140 / -25 to +60 (-401 .................... ........... I ........ t .......... J�q�ectlon Rating NEMA ' * ..... * ........... .............. ... * ....... .......... ............ lu For other regional settings please contact SolarEdge support. A higher current source may be used; the inverter will limit its input current to the values stated. (31 Revenue grade inverter P/N: SExxxxA-1.15000MR2 (for 7600W InvertenSE7600A-US002NN112). _40 version P/N: SEXxmA-US000NNU4 (for 760OW inverter:5E7600A-U5002NNU4). .................................................. <50 dBA ]able(']).......... able(' UPERI 'Iwj.c 801ding-Dg%;nt_ ......... ­ ................. jq Gad A2 RF:11IC1A1r—_ ___ AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: SolarEdge Technologies Ltd Address: 6 Ha'Harash Street 45240 Hod Hasharon Country: Israel Mr. Oren Bachar or Contact: Mr. Meir Adest +972 9 957 6620 #293 or Phone: +972 9 957 6620 #131 FAX: +972 9 957 6591 Email: OREN.B@SOLAREDGE.COM Party Authorized To Apply Mark: Same as Manufacture Report Issuing Office: Cortland, NY 13045 Control Number: 4004590 Authorized by: Manufacturer: Jabil Circuit (Guangzhou) LTD DEV EAST DISTRICT Address: 128 JUN CHENG RD GUANGZHOU GUANGDONG 510530 CHINA Country: China Contact: Elaine Ouyang Phone: 020-2805-4025/ 135-7023-5852 FAX: NA Email: Elaine.ouyang@jabil.com r le. 7 01 for Thomas J. Patterson, Certification Manager This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL 1741 Standard for Safety for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources, Second Edition Dated: January 28, 2010 CSA C22.2 107.1 Issue:2001/09/01 Ed:3 General Use Power Supplies - (R2011) Standard(s): UL SUBJECT 1699B, Outline of Investigation for Photovoltaic (PV) DC Arc -Fault Circuit Protection - Issue No.2, 2013/01/14 CSA TIL M-07, Interim Certification Requirements for Photovoltaic (PV) DC Arc -Fault Protection - Issue No. 1, 2013/03/11 ATM for Report 3188027CRT-001a Page 1 of 8 ATM Issued: 13-Nov-2014 ED 16.3.15 (1-Jan-13) Mandatory AUTHORIZATION TO MARK Product: Utility Interactive Inverter Brand Name: SolarEdge Models: 7 models: SE3000, SE3300, SE3800, SE5000, SE6000, SE7000, SE7600 (Option: followed by A to indicate Interface board, etc.) jt eA `3 2 Wilding DepartMent a REVIEWED FOR CODE ReCOMPS/AfgCE viewed By. G�=G ATM for Report 3188027CRT-001 a Page 2 of 8 ATM Issued: 13-Nov-2014 ED 16.3.15 (1-Jan-13) Mandatory June 20, 2014 Mr. Meir Adest SolarEdge Technologies Ltd 6 Ha'Harash St. HOD HASHARON, ISRAEL 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 756-9891 www.intertek.com Letter Report No. 101703554CRT-001 Project No. G101703554 Ph: +972.9.957.6620 email: meir.a@solaredge.com Subject: ETL Evaluation of SolarEdge Products to NEC Rapid Shutdown Requirements Dear Mr. Meir Adest, This letter represents the testing results of the below listed products to the requirements contained in the following standards: National Electric Code, 2014, Section 690.12 requirement for rapid shutdown. This investigation was authorized by signed Quote 500534459 dated 06/10/2014. Rapid shutdown test were perform at SolarEdge Technologies Ltd, 6 Ha'Harash St HOD HASHARON, ISRAEL and witness by Intertek personal on 06/17/2014. The evaluation covers installations consisting of optimizers and inverters with part numbers listed below. The testing done has verified that controlled conductors are limited to not more than 30 volts and 240 volt- amperes within 10 seconds of rapid shutdown initiation. Applicable products: • Power optimizers: o PBxxx-yyy-zzzz; where xxx is any number, 0-9, up to a maximum value where xxx = 350; yyy could be AOB or TFI; and zzzz is any combination of four letters and numbers. o OP-XXX-LV, OP-XXX-MV, OP-XXX-IV, OP-XXX-EV; where xxx is any number, 0-9. o Paaa, Pbbb, Pccc, Pddd, Peee; where aaa, bbb, ccc, ddd, eee is any number, 0-9 to a maximum upto aaa=300, bbb=350 ccc=500, ddd=600, eee=700. o Pxxx, Pyyy, Pzzz, Pmmm, Pnnn and P000; where xxx, yyy, zzz is any number, 0-9 to a maximum up to xxx=300, yyy=350, zzz=500; where mmm, nnn, 000 is any number, 0-9 to a maximum up to mmm=405, nnn=300, 000=350 a 1-ph Inverters: o SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx-x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix Page 1 of 2 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. >v� BEAS In _rtek Intertek Flltcrtjk Intertek b1tertck Intertek Intertek Intertek Testing Services NA, Inc. So 12.1.2 (11/11/10) Informative SolarEdge Technologies Ltd 0 3-ph Inverters: Letter Report 101703554CRT-001 June 20th, 2014 o SE9KUS / SE10KUS / SE20KUS when the SolarEdge rapid shutdown cable labeled "MCI-CB-xxxxx- x" which is part of kit SE1000-RSD-xx is installed in the inverter Safety Switch where xxxxx-xx is any number; inverter part number may be followed by a suffix This letter report completes this portion of the evaluation covered by Intertek Project No.G101703554. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the undersigned. Please note, this Letter Report does not represent authorization for the use of any Intertek certification marks. Completed by: Radhe Patel Title: Engineering TeamP Lead w'�. Signature: Date June 20 . 2014 Intertek Testing Services NA, Inc. Reviewed by: Howard Liu Title: Staff Engineer Signature Date: June 20 , 2014 UUPERTINO Building Depaftent < REVIEWED FOR CODE COMPLIANCE Reviewed By: --- Page 2 of 2 So 12.1.2 (11/11/10) Informative solar=@@ solar=veSol arEdge Power Optimizer Module Add -On for North America P300 / P400 / P405 SolarEdge Power Optimizer P300 P400 P405 (for 60-cell modules) (for 72 & 96-cell modules) (for thin film modules) Module Add -On For North America INPUT Rated Input DC Powerltl 300 4.00... 405 W ...................................................................................... ............. ® Absolute Maximum Input Voltage 48 80 125 Vdc P300 P400 / P405 •.(Vocat,lowesttemperature) ............................... MPPT Operating Ran a .............g._.4s ............. .............8._.80 ............ 12.5 - 105.......... ....Vdc .... ® Maximum Short Circuit Current (Isc)...... lo................................................ ....Adc .... ..... Maximum DC Input Current 12.5 Adc ................................................. .... I........ % ..................................................... .... .... Maximum Efficiency 99.5 Weighted Efficiency .................................................................. Overvoltage Category II �c OUTPUT DURING OPERATION�'(POWER OPTIMIZER CONNECTED TOOPERATING -INV-ERTER) . = ' Ma ximum Out ut Currnt........ 15 Adc ................. ......................... Maximum Output Voltage 60 85 Vdc OUTPUT DURING T PO NV OU UT URIN STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) •" ® Safety Output Voltage per Power Optimizer 1 Vdc 'STANDARD COMPLIANCE' FCC Part15 .power .............................. .................................... ... .. ... .. .... ... .. ........ ® IVI Class B, IEC61000 6 IEC6100 IEC62109-1 class II safet 2, UL17410 ................Y)....................................... ........... Y. .. ( 6 3 gs�jsta � RoHS Yes INSTALLATION SPECIFICATIONS a I NS Maximum Allowed System Voltage 1000 Vdc stnr: ........................ .. ............................ ..... ... Pxxx2series 141x212x40.5/5.55x8.34x1.59 mm/in # i .. ..... ..... Dimensions (W x L x H) 128x152x27.5/ 128x152x35/ 128x152x48/ Pxxx-5 series mm / in 5x5.97x108 f 5x5.97x1.37 I 5x5.97x1.89 .. xxx 2 series 950/2.1Weight (including cables) 5 series 770/1 7 930/2:05 930 / 2.05 .. L I ..ggrr / jlb b Input Connector MC4 Compatible :. .... Type / Connector ................. Double Insulated; Am henol Output Wlre Out ut Wire Len th 0.95 / 3.0........ ....1.2 / 3.9 ............................ ...m./.ft ... P... ..........g...........................................0.95 0 eratin Tem erature Ran a .................................. ..................... ..... /' p.......g.....p[P�xx_i ........... 40-+85/.40-+185.............................. 'C�'F..Protection Rating serieIP65 / NEMA4 ..........................................................................I................................................ .. . Pxxx 5 series IP68 / NEMA6Pr / Ib Relative Humidity ........... .........I....... 0. 100 `Rated STC power of the module. Module of up to+5%power tolerance allowed. PV power optimization at the module -level — Up to 25% more energy Superior efficiency (99.5%) o Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design, for maximum space utilization ® Fast installation with a'single bolt — Next generation maintenance with module -level monitoring. Module -level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length g 10 18 (Power Optimizers! .................................................................................................................................... .... Maximum String Length 25 25 50 (Power Optimizers)u Maximm Power per String 5250 6.000 12750 W Parallel Strings of Different Lengths Yes or Orientations It Is not allowed to mix P405 with P300/P350/P400/P600/P700 In one string. COPERTINO. FD _A//' _' \ 1 RON RI DGE 'i psi h r - z: Built for A olar's toughest roofs. Roof Mount System IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating t-t ` t7. Certified to maintain the fire resistance rating of the existing roof. Integrated Grounding UL 2703 system eliminates separate module grounding components. PE Certified Pre -stamped engineering letters available in most states. ` 764 Design Software Online tool generates a complete bill of Lam, _ materials in minutes. f7-- 20 Year Warranty Twice the protection offered by competitors. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicant: IronRidge, Inc. Manufacturer: IronRidge, Inc. Address: 1495 Zephyr Ave Address: 1435 Baechtel Road Hayward, CA 94544 Willits, CA 95490 Country: USA Country: USA Contact: Yann Schwarz Contact: Jim Norsworthy Phone: (800) 227-9523 (510) 225-0973 Phone: (800) 227-9523 FAX: (707) 459-1833 FAX: (707) 459-1833 Email: yschwarz@ironridge.com Email: jorsworthy@ironridge.com Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA Control Number: 4007559 Authorized by: r Thomas J. Patterson, Certification Manager ETL CLASSIFIED OTIS�_ USTE Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek's Certification mark is restricted to the conditions laid out In the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road, Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Standard(s): UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat -Plate Photovoltaic Modules and Panels, Issue Number: 1, October4, 2010 Product: XR Rails with Integrated Grounding. Brand Name: N/A Models: 51-61GD-005, 51-61GD-00513, 51-5000-001, and 51-65-001 UPC- R TIN(D 8uilCline Q '� '�`�' t9•L�.��IYl �3 � '4 ^F e•Da``�r{ �} elll REVIEWED EVI EWEG FOR CODE CO ° r �} RevieWed� ' CI_ ATM for Report 101541132LAX-002 Page 1 of 3 ATM Iss�O=�fov=2014 ED 16.3.15 (1-Jan-13) Mandatory RON RI DGE Sirnpiffied Orovin in' - For Greater Safety & Lower Cost Traditionally, solar modules are grounded by attaching lugs, bolts or clips to the module frame, then connecting these to a copper conductor that runs throughout the array. This process adds time and cost to the installation, and often results in improper grounding, creating significant long-term safety risks. The IronRidge Integrated Grounding System solves these challenges by bonding modules directly to the mounting rails. This approach eliminates separate module grounding hardware, and it creates many parallel grounding paths throughout the array, providing greater safety for system owners. ,a 1 2 it € r > Grounding Strap Grounding Straps are used to zy.a. cF bond rail -to -rail connections. They are only required on the �. rail with the grounding lug. Integrated Grounding System Installation Overview Install Roof Attachments t�i ;. - • Install appropriate roof flashing and/or standoff for roof type j> �. • Attach L-Feet to flashing or standoff. F - 1 Prepare Rail Connections is ;•, • Insert splice into first rail, then secure with Grounding Strap and self -drilling screw. • Slide second rail over splice, then secure with opposite end of Grounding Strap and self -drilling screw. Mount & Ground Rails • Attach rails to L-Feet and level rails. Grounding Mid Clamp • Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through the anodized coatings of both the module frame and • Connect Grounding Lug to grounding conductor. the mounting rail to form secure electrical bonds, which are repeated throughout the array. ^1 Install Modules & Clamps Grounding Lug Asingle Grounding Lug connects an entire row of PV modules to the grounding conductor. • Install first module using End Clamps and Grounding Mid Clamps. • Install additional modules using Grounding Mid Clamps. • Finish row with a second pair of End Clamps. Testing & Certification The IronRidge Integrated Grounding System has been tested and certified to UL 2703 by Intertek Group plc. UL 2703 is a proposed UL standard for evaluating solar module mounting and clamping devices. It ensures these devices will maintain strong electrical and mechanical connections over an extended period of time in extreme outdoor environments. The testing process closely mirrors that of UL 1703, the solar module testing standard, including temperature and humidity cycling, electrical and mechanical load testing, and manufacturing quality reviews. Module Frame Compatibility Dimension Range A 31.Omm - 51.Omm B 5.08mm (minimum) Any module frames whose parameters are not listed in the provided table have not been tested for compatibility. The Grounding Clamp has proven robust in grounding 60-cell and 72-cell solar module frames with box construction and a range of anodization thicknesses. All solar modules listed to UL 1703 and with frame construction within the parameters stated above are compatible with the IronRidge Integrated Grounding System. Go to ire •t° y ;onifig U i INO Building i3,2;art;nan! tj L Y sm_ IronRidge 1495 Zephyr Ave Hayward, CA 94544 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers 5224 South 39th Street, Phoenix, Arizona 85040 tel: (602) 438-2500 fax: (602) 438-2505 ROC#291316 www.smleng.com Attn: Mr. David F. Taggart, Vice President Products December 18, 2014 Page 1 of 20 Subject: IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Dear Sir: We have analyzed the IronRidge XR10 Rail for the subject solar module support system and determined that, for the configurations and criteria described below, it is in compliance with the applicable sections of the following Reference Documents: Codes: ASCE/SEI 7-10 Min. Design Loads for Buildings & Other Structures California Building Code 2012 Edition Other: AC428, Acceptance Criteria for Modular Framing Systems Used to Support PV Modules, dated Effective November 1, 2012 by ICC-ES Aluminum Design Manual, 2010 Edition The IronRidge XR10 Rail is an extruded aluminum section with an overall depth of 1.75 in. and a net area of 0.363 sq.in. The rails are used to support solar modules, typically, on the roof of a building. See Exhibit A — attached. The rails are clamped to aluminum angle brackets that are either attached directly to the roof framing or attached to a stand that is screwed to the roof framing. The rails are mounted across the slope with a small clearance (flush mounting) to the underlying roof structure. The installed solar modules are at the same slope as the underlying roof structure. All loads are transferred to the roof framing through the angle brackets by simple bi-axial flexure of the rails. The maximum span of the rails is governed by either the mid -span flexural stresses or the deflection requirement that the rail not come into contact with the roof. The effect of seismic loads (for all design categories A-F) have been determined to be less than the effect due to wind loads in all load conditions and combinations. Therefore, the maximum allowable spans for common load cases are shown in the tables below. Tables 1A-9A are for modules with a maximum long dimension of 67.5 inches and Tables 1B-9B are for modules with a maximum long dimension of 78.5 inches. Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 5 of 20 Table 4A - MAXIMUM SPANS (in) - Roof Slope 7' to 270 - Wind Zone 1 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 75 65 55 49 43 39 35 33 31 29 Category B 130 75 65 55 49 43 39 35 33 31 29 140 71 65 55 49 43 39 35 33 31 29 150 66 65 55 49 43 39 35 33 31 29 160 62 62 54 48 43 39 35 33 31 29 170 59 59 53 1 47 43 1 39 35 33 1 31 29 100 75 65 55 49 43 39 35 33 31 29 105 75 65 55 49 43 39 35 33 31 29 110 75 65 55 49 43 39 35 33 31 29 120 70 65 55 49 43 39 35 33 31 29 Category C 130 65 64 54 48 43 39 35 33 31 29 140 60 60 53 48 43 39 35 33 31 29 150 56 56 1 52 47 43 39 35 33 31 29 160 1 53 53 51 46 1 42 39 1 35 33 31 1 29 170 50 50 50 45 41 38 35 33 31 29 100 75 65 55 49 43 39 35 33 31 29 105 73 65 55 49 43 39 35 33 31 29 110 70 65 55 49 43 39 35 33 31 29 120 64 64 54 48 43 39 35 33 31 29 Category D 130 60 60 1 53 47 43 1 39 35 1 33 31 29 140 55 55 52 46 42 39 35 33 31 29 150 52 52 50 46 42 39 35 33 31 29 160 49 49 49 45 41 38 35 33 31 29 170 46 46 46 1 44 40 37 1 35 33 1 31 1 29 Notes — see page 20 Starling Madison Lofquist, Inc. CUPERTINO " 6 Building DeP@ftent .:z 6 REVIEWED FOR CODE COMPLIANCE Reviewed By: -5- Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 6 of 20 Table 5A - MAXIMUM SPANS (in) - Roof Slope 7° to 27'- Wind Zone 2 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 72 65 55 49 43 39 35 33 31 29 105 69 65 55 49 43 39 35 33 31 29 110 66 65 55 49 43 39 35 33 31 29 120 60 60 55 49 43 39 35 33 31 29 Category B 130 56 56 55 49 43 39 35 33 31 29 140 52 52 52 49 43 39 35 33 31 29 150 49 49 49 49 43 39 35 33 31 29 160 46 46 46 46 43 39 35 33 31 29 170 43 43 43 43 43 39 1 35 33 1 31 29 100 61 61 55 49 43 39 35 33 31 29 105 58 58 55 49 43 39 35 33 31 29 110 56 56 55 49 43 39 35 33 31 29 120 51 51 51 49 43 39 35 33 31 29 Category 130 48 48 48 48 43 39 35 33 31 29 C 140 44 44 44 44 43 39 35 33 31 29 150 41 41 41 41 41 39 35 33 31 29 160 39 39 39 39 39 39 35 33 31 29 170 36 36 36 36 36 36 35 33 31 29 100 56 56 55 49 43 39 35 33 31 29 105 54 54 54 49 43 39 35 33 31 29 110 52 52 52 49 43 39 35 33 31 29 120 47 47 47 47 43 39 35 33 31 29 Category 130 44 44 44 44 43 39 35 33 31 29 D 140 41 41 41 41 41 39 35 33 31 29 150 38 38 38 38 38 38 35 33 31 29 160 36 36 36 36 36 36 35 33 31 29 170 1 33 1 33 1 33 1 33 1 33 1 33 1 33 1 33 1 31 1 29 Notes — see page 20 Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers IronRidge Mr. David F. Taggart IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis December 18, 2014 Page 7 of 20 Table 6A - MAXIMUM SPANS (in) - Roof Slope 7'to 27° - Wind Zone 3 (67.5" Max Module Length) XR10 Rail Wind Speed Ground Snow Load Exposure mph 0 psf 10 psf 20 psf 30 psf 40 psf 50 psf 60 psf 70 psf 80 psf 90 psf 100 59 59 55 49 43 39 35 33 31 29 105 56 56 55 49 43 39 35 33 31 29 110 54 54 54 49 43 39 35 33 31 29 120 49 49 49 49 43 39 35 33 31 29 Category B 130 46 46 46 46 43 39 35 33 31 29 140 42 42 42 42 42 39 35 33 31 29 150 40 40 40 40 40 39 35 33 31 29 160 37 37 37 37 37 37 35 33 31 29 170 35 35 35 35 35 35 35 33 31 29 100 50 50 50 49 1 43 39 35 33 31 29 105 48 48 48 48 43 39 35 33 31 29 110 45 45 45 45 43 39 35 33 31 29 120 42 42 42 42 42 39 35 33 31 29 Category C 130 39 39 39 39 39 39 35 33 31 29 140 36 36 36 36 36 36 35 33 31 29 150 33 33 33 33 33 33 33 33 31 29 160 31 31 31 31 31 31 31 31 31 29 170 29 29 29 29 29 29 29 29 29 29 100 46 46 46 46 43 39 35 33 31 29 105 44 44 44 44 43 39 35 33 31 29 110 42 42 42 42 42 39 35 33 31 29 120 38 38 38 38 38 38 35 33 31 29 Category 130 35 35 35 35 35 35 35 33 31 29 D 140 33 33 33 33 33 33 33 33 31 29 150 31 31 31 31 31 31 31 31 31 29 160 29 29 29 29 29 29 29 29 1 29 29 170 1 27 1 27 1 27 1 27 1 27 1 27 1 27 27 1 27 27 Notes — see page 20 f�f C _ wo v: d wild " ��cel✓> pnf RE V1EVl;Eti FGj� ODE COil'lPLl Reviewed By - f�C Starling Madison Lofquist, Inc. Consulting Structural and Forensic Engineers -6- -7- IronRidge December 18, 2014 Mr. David F. Taggart Page 20 of 20 IronRidge XR10 Rail, Roof Flush Mounting System — Structural Analysis Notes — Tabulated values are based on the following criteria: l . Building mean roof height = 30 ft 2. Risk Category I 3. Solar maximum module long dimension is 67.5 inches for Tables IA-9A and 78.5 inches for Tables 1 B-9B. 4. Provide 2 in. clear between roof and rail 5. End cantilever span (max) = 0.40 x maximum span from above tables 6. No rail splices in end spans 7. No rail splices in middle 1/3 of interior spans 8. Single simple span(s). Spans listed in the tables above may be multiplied by 1.08 for continuous rails of 3 or more spans. Our analysis assumes that the rails, including the connections and associated hardware, are installed in a workmanlike manner in accordance with the "IronRidge Roof Mount Installation Manual" by IronRidge and generally accepted standards of construction practice. Additional information is available at the IronRidge web site, IronRidge.com. Verification of PV Module capacity to support the loads associated with the given array shall be the responsibility of the Contractor or Owner and not IronRidge or Starling Madison Lofquist. The adequacy of the supporting roof framing is to be determined by others. Please feel free to contact me at your convenience if you have any questions. Respectfully yours, Tres Warner, P.E. Design Division Manager Starling Madison Lofquist, Inc. 4�0Cr�,S,tf V. C ► i ° 3 _20- Consulting Structural and Forensic Engineers 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. plicant Name & Address: Product Description: Ratings & Principle Characteristics: IronRidge, Inc. 1495 Zephyr Ave. Hayward, CA 94544 USA XR Rails with Integrated Grounding. Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2 and 3, listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Typel, 2 and 3, Fisted photovoltaic modules. Tested with a 5" gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. Models: 151-61GD-005, 51-61GD-005B, 51-5000-001 and 51-65-001 Brand Name: Relevant Standards: Verification Issuing Office: Date of Tests: Test Report Number(s): IronRidge Roof Mount UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31,2) Standard for Safety for Flat -Plate Photovoltaic Modules and Panels. Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 08/27/2014to 03/17/2015 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chad Naggs Title: Technician II, Fire Resistance Signature: Date: 03/30/2015 Reviewed by: Gregory Allen Title: Engineering Team Lead, Fire Resistance Signature:�'���JI Date: 03/30/215t a CUP RTINO auilrjiEn` - Ii ��e This Verification is for the exclusive use of Intertek's client and is provided pursuant to the grFjz rArrtWEe T,ot ifi,A oq� Cli t� �vertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance iFrfth the bgtVent, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copyirR&4'"l Etd � his ve Y_cafWny use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Th se tions and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product or service is or has ever been under on Intertek certification program. GFT-OP-11a (24-MAR-2014) E-Mount Lag J*QMSE - LAG �— 9.00 2.25 �F RIDGE NO. DESCRIPTION QTY./BOX 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CLASSIC, A360.1 CAST AL, MILL 1 3 PLUG, SEALING, 5116" X 7/8", EPDM / 18-8 SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 5-1/2", 18-8 SS 1 5 WASHER, FENDER, 5/16" ID X 1-1/4" OD, 18-8 SS 1 j Cuick Mount PV TITLE: QMSE-LAG: QMPV E-MOUNT AVAILABLE IN MILL, AND ; WITH LAG BOLT 3RONZE ANODIZED FINISHES ! FROPMETARY AND CONFIDENTIAL MEINFORMATION CONTAINED IN THIS DRAWING 5 THE SOLE PROPERTY OF QUICK MOUNT PV. ANYREPRODUCDONINPARTORAS A W HOIF WRHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHRIRED. 5 7— 4 TOLERANCES: FRACTIONAL! 118 DO NOT SCALE DRAWING TWO PLACEDECIMAL S.IB THREE PLACE DECIMAL 2.125 3 2 SIZE 1 DRAWN BY: DFM REV Al DATE: 8/29/2014 j I ;CALE: 1:3 I WEIGHT:0.96 I SHEET I OF I I 1 Lag pull-out (withdrawal) capacities (Ibs) in typical lumber: Lag Bolt Specifications Specific Gravity 5/16" shaft per 3" thread depth 5/16" shaft per V thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South. .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f & higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See NDSTable 11.5.1 C for required edge distances. Quick M0unt PY) RESPECT T'HE RCI E-Mount Lag Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" long -style bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be Carefully lift composition roof shingle with roofing Insert flashing between 1 st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove nails up so top edge of flashing is at least 3/4" higher mounts will be placed. as required. See "Proper Flashing Placement" on than the drip edge of the 3rd course and lower next page. flashing edge is above the drip edge of 1 st course. Mark centerfor drilling. Using drill with 7/32" bit, drill pilot hole into roof - and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill should be 'long style bit, aka'aircraft extension bit'to drill a 13/4" deep hole into rafter. Slide the washer and the L-foot (not included) onto the lag screw. BI 7.2.3-31 Sep-2014, Rev 1 BI 7.2.3-31 Clean off any sawdust, and fill hole with sealant Slide the flashing into position. Insert the rubber compatible with roofing materials. plug into the QBlock cavity. Using a 1/2 inch socket on an iml the lag screw until the QBlock stops DO NOT over -torque. Sep-2014, Rev 1 REVIEWED FOR CODE COM PUANCE Reviewed By:-- —_ a ■d� L.111 Product Datasheet ENERGY The LGate 120 combines a revenue -grade, solid-state power meter with an advanced communications gateway. These components work in conjunction to remotely monitor the performance of residential solar energy installation regardless of panel or inverter type. The LGate 120 is a one-piece completely under glass meter which installs easily using a standard socket base. Performance data is uploaded in near real-time to the Locus Energy SolarOS monitoring platform which provides a suite of tools and analytics for asset managers. DATA COLLECTION AC energy data is collected by the meter and passed to the communications module. Additional system performance data can be collected directly from meteorological sensors and supported inverters via available RS-485 or Zigbee connections. All data is stored in non-volatile memory and then automatically uploaded to the SolarOS and SolarNOC platforms. NETWORK CONNECTIVITY The communications gateway inside the LGate 120 supports plug and play connectivity through a cellular or available Ethernet network connection. Once the unit is installed and powered on, it will immediately begin transmitting data without any configuration. For maximum reliability, the communications gateway will automatically route uploads between the wireless and wired connections if either of the networks are unavailable. FEATURES • ANSI C12.20 power meter • RS-485 and Zigbee inputs • GSM cellular or Ethernet connectivity • Over the air firmware updates • Easy, low cost installation • Doesn't require entrance into the building • Plug and play activation • LCD display DIAGRAM - TYPICAL CONFIGURATION Gomm 1 :I®M :AMM `— Shielded CATS INTERNET ' fI®� l♦� it t..iAll�- l♦- �._ ELECTRICAL SERVICE INVERTER(S) LGATE 120 PV ARRAY DIMENSIONS LOCUS ENERGY i METER BASE i COMM MODULE METER MODULE I EZ i I a SPECIFICATIONS DATALOGGER Processor ARMS embedded CPU ' OS Custom version of Linux 2.6, OTA firmware updates Memory 128 MB RAM' Display LCD screen Enclosure"'1 NEMA 3R Type Weight 8 oz Dimensions 6.957x 6.5" x 7.3" Environment -20 to 60C,,all-weather Warranty, 5year limited warranty INTERFACECOMMUNICATION ModelNumber _ - - - LGate120-3Gx LGate120-3Gy LGate120-3Gz Cellular - 3G GSM ✓ J ✓ RS-4852 and 4 wire Modbus Zigbee J Ethernet RJ-45 10/100; ;DHCP/Static ✓ SOCKET METER 6.S Accuracy ANSI 12.20 (Class 0.2%) Voltage Inputs .120 - 480 VAC Max. Current Input 200 A Service Type Single phase ; 60 Hz Socket Type- 2S COMPLIANCE ANSI 12.20 class 0.2%, ' FCC Part 156 PTCRB AT&T Carrier Compliance tt BIjilding ns1)<�m�r. � ' y • i 5f' r. K16 REVIEWED r(-C, 9E. Reviewed By.- Single Meter Sockets -Without Bypass 125 & 200 Amp 011 (closed) U204(open) Application • Single meter position • Receive ANSI C12.10 watthour meters • Surface or flush mount (see chart) Construction • Ring type • NEIVIAType 3B UL • ANSI 61 gray E-coat finish • Aluminum snap ring included Standards Accessories • UL 414 Listed • 5th Jaw Kit - 50365 • ANSI C12.7 • 200ATriplex Ground - ETB200 • AW Hub Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral 78205142000 011 125 4 10/3W 0H/UG #14 -2/0 #14 - 2/0 #14 - 2/0 78205142040 011 F 125 4 10/3W 0H/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142045 011 MS73 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205142050 011 SF 125 4 10/3W OH/UG #14 - 2/0 #14 - 2/0 #14 - 2/0 78205144030 927 100 7 _ 30/4W 0H/UG #14 -1/0 #14-- 1/6 #14 -2/0 78205156000 204 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78.205156020 204 F 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156030 204 F MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156040 204 MS68 200 4 10/3W 'OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156035 204 MS68A 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205108490 204 MS73 200 4 10/3W OH #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156005 U204 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156045 U204 F - 260 4 10/3W UG #6 - 250MCM #6-250MCM #6 - 350MCM 78205156060 U204 F MS73 200 4 10/3W UG #6 - 250MCM #6 - 250MCM #6 - 350MCM 78205156070 U204 MS73 200 4 10/3W UG #&-250MCM #6 - 250MCM #6 = 350MCM 78205156140 U207 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156170 'W07 IF 200 7 30/4W UG #6 - 250MCM #6 - 250MCM #6 - 250MCM 78205156180 U207 MS73 200 7 30/4W OH/UG #6 - 250MCM #6 - 250MCM #6 - 250MCM ParUUPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout 78205142000 011 12" 8"_ ON' AW Hub Fig.1 78205142040 011 F 12" 8" 45/8" 2" max KO Fig. 1 7820,51420,415 011 MS73 12" 8" 45/8" AW Hub Fig.1 78205142050 011 SF 12" 8" 45/9" 2" max KO Fig. 1 78205144030 927 17" 8" 45/3" AW Hub Fig. 1 78205156000 204 15" 8" ON' AW Hub Fig. 2 78205156020 204 F 15" 8" 6" 2" max KO Fig. 2 78205156030 204 F MS73 15" 8" 6" 2" max KO Fig. 2 78205156040 204 MS68 15" 8" 45/s" AW'/ 2" Hub Fig. 2 78205156035 204 MS68A 15" 8" 45/3" AW / 2" Hub Fig. 2 78205108490 204 MS73 15" 8" 45/8" None Fig. 2 78205156005 U204 15" 12" 45/s" None Fig.3 78205156045 U204 F 15" 12" 6" (2) 2" max KO Fig. 3 78205156060 U204 F MS73 15" 12" 6" None Fig. 3 78205156070 6204 MS73 15" 12" 45/8" None Fig. 3 78205156140 U207 18" 12" 5" AW Hub Fig. 4 AIC Note: 78205156170 U207 F 18" 12" 5" 21/2" max KO Fig. 4 For short circuit current 78205156180 U207 MS73 18" 12" 5" AW Hub Fig. 4 ratings see page 131. B-Line by FAT-N Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment Single Meter Sockets -Without Bypass 011 F - Flush Mount (U) 204 MS68 - 2" Conduit Hub (U) 207 MS68A - MS73 + MS68 927 MS73 - AL Screw Type Ring SF - Semi Flush Mount SS - Stainless Steel Knockout Layouts Fig. 1 Top Provision 01 4F 4F o n sides 1A Fig. 3 Top Provision 4F 413 \ / 4F 5 des e O 4G 1 W 125 & 200 Amp 1 W = 1/4' 1 A = 1/2" 2A = 1/2' - 1/4' 4F=2"-11/2"-11/4"-1" 4G=21/2"-2"-11/2"-11/4' Top Provision = See Chart Fig. 2 o Top Provision 0 4F both sides 4F 1A Fig. 4 Top Provision 0 4G 4G 4G btG sides 413 2A Data subject to change without notice. Consult local utility for area acceptance. All dimensions are in inches. Meter Mounting Equipment 6 C M. 0 C1 �- C � N . 0 I ti I= lain �11W ENERGY October 22"d, 2013 This letter is to certify that the LGate 120 and LGate 320 are communication boards built into the Vision Meter 2S CL200 and 16S CL320 socket meters, respectively. Each of these meters was certified to the ANSI C12.20 (class 0.2%) standard by Underwriters Laboratory on June 7, 2013 as part of the Vision Meter Family (Project Number 12CA71134, Job Number 1001541515, and Report Number R12CA71134- ANSI). ANSI C12.20 is currently recognized as the industry standard for electrical socket meters in both utility and PV monitoring applications. These tests cover both meter accuracy as well as several safety standards including electrical and environmental safety, as well as resistance to various types of mechanical shock. As electrical socket meters are generally installed and maintained by trained and certified professionals, rather than consumers, they do not fit the typical criteria for additional types of UL or IEC certification. If you have any further questions regarding the product certification of any Locus Energy LGate-branded device, please contact us at support@ locusenergy.com. The Locus Energy Team ( -_ Cj 'il `X p_ p C) a 0 0 V y. O I r_ D 0 Locus Energy, LLC www.locusenergy.com Classic Conduit Composition Mount I QMCC .79 i ! I f I ....____....._................._...... .. ....._...._............_... rROrtl"ARY AN D CONEIDENRAL I rHEIMORMANONCOMAINEONT DRAW GM1 ESOLEPROPERITOFWICKMOUMPV. ANY REPROOUCTIONINPARTORAS A WHO ITHOUT THE VMTREN PERMSSION OF QUICK MOUNT TV D PROHBREO. --� 5 4 ITEM NO. DESCRIPTION QTY. 1 FLASHING, 9" X 12" X .040", 5052, MILL 1 2 QBLOCK, CONDUIT, 5/16", 6061-T6, MILL 1 3 WASHER, SEALING, 1/4" ID X 7/8" OD, EPDM 1 BONDED SS 4 LAG SCREW, HEX HEAD, 1/4"x2-1/2", 18-8SS 1 AVAILABLE IN MILL, CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. WU1CK mount t`w TITLE: QMCC: CLASSIC CONDUIT COMPOSITION MOUNT u NLcaa v ncrtvvnc arcs. rlcu _.._.—SIZE DRAWN BY: RAD REV DIME ! DIMENSIONS ARE IN INCHES , NCES:_ __ i FRACTIONAL- I/a A DATE 9/24/2013 4 Two PLACEDECIMAL S.l8---------- DO NOT SCALE DRAWING I ! THREE PLACE DECIMAL 2.125 : SCALE: 1:3� WEIGHT:0.68 I SHEET I OF I 3 2— 1 Lag pull-out (withdrawal) capacities (Ibs) in typical lumber: Lag Bolt Specifications Specific Gravity 1/4" shaft per 1 3/4" thread depth 114" shaft per 1" thread depth Douglas Fir, Larch .50 393 225 Douglas Fir, South .46 353 202 Engelmann Spruce, Lodgepole Pine (MSR 1650 If & higher) .46 353 202 Hem, Fir .43 313 179 Hem, Fir (North) .46 353 202 Southern Pine .55 455 260 Spruce, Pine, Fir .42 302 173 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 393 225 Sources: American Wood Council, NDS 2005,Table 11.2 A,11.3.2 A Notes: 1) Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. IMPORTANT: To maintain waterproofing it is important that the aluminum flashing (item 1) is properly placed under one full course above the mounting block with at least some of the flashing extending up under the course above that ac wall Caa inctrLlrtinnc nn hartr Quick Mount PV RESPECT THE ROOF BI 7.2.3-8 Aug-2014, Rev 4 BI 7.2.3-8 Classic Conduit Mounting Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun,1 tube of appropriate sealant, drill with 1/8" bit, drill or impact gun with 7/16" deep socket. Choose placement of conduit mounts along path Lift composition roof the with roofing bar, just Slide conduit mount into desired position. Remove of conduit. Select location over center of rafter. above placement of conduit mount. any nails that conflict with getting the mount flush with front edge of shingle course. Mark cernter for drilling. Using drill with 1/8" long bit, drill pilot hole into roof and rafter, taking care to drill square to the roof. Clean off any sawdust, and fill hole with roof Lift shingle and slide conduit mount into place. manufacturer's approved sealant. Prepare lag bolt with sealing washer and single hole clamp (not included) as shown. Insert lag through hole in block, and position clamp over conduit. instructions must also be lowed by anyone modifying a f system. Please consult the E [roof manufacturer's specs and • the roof. kC X C) zz. Insert lag through hole in block, and position (7 tv a clamp over conduit. Using drill with 7/16" socket, 25� fQ drive lag until block is tight. \157. Quid Mount PV`,/_� z 0 925-478-8269 • www.quickmountpv.com • info@quickmountpp..rom 2700 Mitchell Dr.Bld2 •Walnut CreekCA 94598 , g , Aug-2014, 0ev4 ©2013 by Quick Mount PV. All rights reserved. CUPERTINO Address 1 PURPOSE 51111064E / CARBON MONOXIDE ALARMS OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT > BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 - FAX (408) 777-3333 • building aQcupertino.org PER HT CANNC I-IAS BEEN of ;D UNTIL TINS CERTIFICATE �i+. I3T1T.7lI1V� �i[Tir�7[3i3 _ .. . T11is affidavit is a self -certification for the installation of all required Smoke and Carbon Monoxide Alarms for compliance with 2013 CRC Section R314, 2013 CBC Sections 420.6 and 907.2.11.2 where no interior access for inspections are required. GENERAL INFORMATION Existing single-family and multi -family dwellings shall be provided with Smoke Alarms and Carbon Monoxide alarms. When the valuation of additions, alterations, or repairs to existing dwelling units exceeds $1000.00, CRC Section R314 and CBC Sections 907.2.11.5 and 420.6 require that Smoke Alarms and/or Carbon Monoxide Alarms be installed in the following locations: AREA SMOKE ALARM CO ALARM Outside of each separate sleeping area in the immediate vicinity of the bedroom(s) X X On every level of a dwelling unit including basements X X Within each sleeping room X Carbon Monoxide alarms are not required in dwellings which do not contain fuel -burning appliances and that do not have an attached garage. Carbon monoxide alarms combined with smoke alarms shall comply with CBC Section 420.6 and shall be approved by the Office of the State Fire Marshal. Power Supply: In dwelling units with no commercial power supply, alarm(s) may be solely battery operated. In existing dwelling units, alarms are permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. Refer to CRC Section R314 and CBC Sections 907.2.11.4 and 420.6.2. An electrical permit is required for alarms which must be connected to the building wiring. As owner of the above -referenced property, I hereby certify that the alarm(s) referenced above has/have been installed in accordance with the manufacturer's instructions and in compliance with the California Buildirig and California Residential Codes. The alarms have been tested and are operational, as of the date signed below. I have read and agree to cbmg9y with the termond cpnditions of this statement I Owner (or Owner Agents) Name: j f/ p r rkl Signature .. k�� ......... ...... .........�.. �r-��.....................I.................. .. Dater �� (t� Contractor Name: 0 n 6 v- � Si nature... ....... ....... , M.................................. ff II .............. Ltc.# ......... ......... Date:.. Smoke and CO forms. doc remised 03118114 WATER -CONSERVING PLUMBING FIXTURES ` FILE OWNER CERTIFICATE OF COMPLIANCE COMMUNITY DEVELOPMENT DEPARTMENT - BUILDING DIVISION ��.�.�� 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408), , 77-3228 • FAX (408) 777-3333 buildina&cupertino.or_q Owner Name&til� Permit Non c [ Address n 100S Iffeks, A �iLl7//��' � / —7 ° 1. Is your real property a registered historical site? El Yes Civil Code Sections 1101.1 through 1101.8 :do not apply. Skip the rest of the form and sign bottom of form. P No Go to Question 2. 2. Does your real property have a licensed plumber certifying that, due to the age or configuration of the property or its plumbing, installation of water -conserving plumbing fixtures is not technically feasible? Yes Civil Code Sections 1101..1 through 1101.8 do not apply. El The licensed plumber's certification has been provided to the Building Division. Skip the rest of the form and sign bottom of form. Ij RrNO Go to Question 3. f 3. Is water service permanently disconnected for your building? Yes Civil Code.Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. j2-No Go to Question 4. 4. Is your real property built and available for use or occupancy on or before January 1, 1994? n No My real property is built and available for use or occupancy after January 1, 1994. Civil Code Sections 1101.1 through 1101.8 do not apply. Skip the rest of the form and sign bottom of form. ,,r Yes My real property is built and available for use or occupancy on or before January 1, 1994. Civil Code Sections 1101.1 through 1101.8 apply. Check one of the three following statements and sign bottom of form.. 5. Please check ONE of the following: 0 IRr My property is a single-family residential real property. See Civil Code Section 1101.4. On and after January 1, 2014, building alterations or improvements shall require all non -compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures throughout the building. On or before January 1, 2017, all non- compliant plumbing fixtures shall be replaced with water -conserving plumbing fixtures (regardless of whether property undergoes alterations or improvements). El My property is a multifamily residential real property. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water - conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or - improvements). My property is a commercial real property.. See Civil Code Section 1101.5. On and after January 1, 2014, specified building alterations or improvements shall require non- compliant plumbing fixtures to be replaced with water -conserving plumbing fixtures. On or before January 1, 2019, all non -compliant plumbing fixtures shall be replaced with water- conserving plumbing fixtures throughout the building (regardless of whether property undergoes alterations or improvements). 1, as the owner or owner's agent of this property, certify under penalty of perjury that non -compliant plumbing fixtures will be replaced prior to date specified above with water -conserving plumbing fixtures in accordance with Civil Code Sections 1101.1 through 1101.8, the current California Plumbing Code and California Green Building Standards Code, and manufacturer's installation requirements, and that the water- onserving plumbing fixtures comply with the requirements as indicated in the table on the following naae. /7 ,a .� % % Ol 1 , Owner or Owner Agent's Upon completing and signing this Certificate, please return it to the Building Division in order to final your building SB407 2015.doe revised 08126115