Loading...
10040071 4 F44 PUBLIC WORKS . t t • t • • I I t m CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22284 N DE ANZA CfR CONTRACTOR:REGRID POWER PERMIT NO: 10040071 OWNER'S NAME: BLAINE RICHARD A AND SHARON TR 1624 DELL AVE DATE ISSUED:04/20/2010 OWNER'S PHONE: 4082576410 CAMPBELL,CA 95008 PHONE NO:(408)927-0811 LICENSED CONTRACTOR'S DECLARATION r r r BUILDING PERMIT INFO: BLDG ELECT PLUMB License Class A CIO C WLic.#& t5 73,& MECH r RESIDENTIAL r COMMERCIAL r Contractor /1ee-1,N Awry Ag&W Date t��}110 I hereby affirm hat 1 a ed un pjog" rovisions of Chapter 9 JOB DESCRIPTION: INSTALL ROOF MOUNTED PV(SOLAR)-NO (commencing with Section 7000)of Division 3 of the Business&Professions BATTERIES;REGRID POWERDBA REAL GOOD SOLAR RENWD Code and that my license is in full force and effect. BSL 1 hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this Sq.Ft Floor Area: Valuation:$25835 permit is issued. APPLICANT CERTIFICATION APN Number:35602028.00 Occupancy Type: I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save PERMIT EXPIRES IF WORK IS NOT STARTED indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR granting of this permit. Additionally,the applicant understands and will comply 180 D 9#OM LAST CALLED INSPECTION. with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. fl(� Signature Date Issued by: Date: O OWNER-BUILDER DECLARATION RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law for one of All roofs shall be inspected prior to any roofing material being installed.If a roof is the following two reasons: installed without first obtaining an inspection,1 agree to remove all new materials for I,as owner of the property,or my employees with wages as their sole compensation, inspection. will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) Signature of Applicant: Date: I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec.7044,Business&Professions Code). ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I hereby affirm under penalty of perjury one of the following three declarations: HAZARDOUS MATERIALS DISCLOSURE 1 have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the I have read the hazardous materials requirements under Chapter 6.95 of the performance of the work for which this permit is issued. California Health&Safety Code,Sections 25505,25533,and 25534. 1 will maintain I have and will maintain Worker's Compensation Insurance,as provided for by compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& Section 3700 of the Labor Code,for the performance of the work for which this Safety Code,Section 25532(s)should I store or handle hazardous material. Additionally,should I use equipment or devices which emit hazardous air permit is issued. contaminants as defined by the Bay Area Air Quality Management District 1 will I certify that in the performance of the work for which this permit is issued,I shall maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the not employ any person in any manner so as to become subject to the Worker's Health&Safety Code,Sections 25505,25533,and 25534. Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,1 must Owner 9r autho , agent: forthwith comply with such provisions or this permit shall be deemed revoked. Date: APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is I hereby affirm that there is a construction lending agency for the performance of work's correct.I agree to comply with all city and county ordinances and state laws relating for which this permit is issued(Sec.3097,Civ C.) to building construction,and hereby authorize representatives of this city to enter Lender's Name upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, Lender's Address costs,and expenses which may accrue against said City in consequence of the granting of this permit.Additionally,the applicant understands and will comply ARCHITECT'S DECLARATION with all non-point source regulations.per the Cupertino Municipal Code,Section 9.18. 1 understand my plans shall be used as public records. y Signature 1�G/kt 04= Date v t r! Licensed Professional CITY OF CUPERTINO LM SOLAR PANEL PERMIT APPLICATION FORM CUPERTINO APN #35 O 2- () 0 Date: l � 2 Building Address: , aaa8y .-cC-e Owner's Name: Phone#: Contractor: Phone#: L(o f-?7o-16 0V Contractor License#: Ri-e nd Po we, .opr SD!a. Fax#: Qo oY- 7 a Contact: // Phone#: ct o f-Y/o- 24(,y Cupertino Business License#: �CL 1Yk V)ell Fax#: Y(/ '- �4 Y-S Y 7 Job Description: Residential Commercial ❑ Number of Panels/Units: Kilowatts: Valuation cost of project): a S) $ 3 S Project Size: Express StandardEl Large L Major 71 Green Points: 1.2 KW—6 Points ❑ 2.4 KW— 12 Points ❑ 3.6 KW— 18 Points Quantity Fee ID Fee Description Fee Permit Type Group 1 SOLARPANL Commercial Solar Panel E SOLAR-COMM 1PHOTOVCOM Photovoltaic System E Comrnercial/Multi-family 1BSEISMICO Seismic Commercial E IELCPLNCK Plan Check Fee E 1BCBSC Cal Bldg Standards B ALL PERMIT TYPES Commission Fee COMM & RESID 1 SOLARRES Residential Solar Panel E SOLAR-RES Revised 08/20/2009 CITY OF CUPERTINO SOLAR PANEL PERMIT APPLICATION FORM CUPERTINO Quantity Fee ID Fee Description Fee Permit Type Group 1PHOTOVRES Photovoltaic System E Residential 1TRAVDOC Travel &Documentation B 1BUSLIC Business License B r Building Department City Of Cupertino 10300 Torre Avenue Cupertino,CA 95014-3255 Telephone: 408-777-3228 C U PE RTI N O Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: 7-2a gy /V, a za rcle PERMIT# ZaQ It 00? OWNER'SNAME: Ric -4- S! oN SLMIME PHONE# Yolt- 0 GENERAL CONTRACTOR: Qe9gl-of Paw er .00s Sot BUSINESS LICENSE# ADDRESS: Dell Aoe. a,r. otf CITY/ZIPCODE: 'Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: z�U Signature Date Please check applicable subcontractors and complete the following information: V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass /Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile �" V Owner/Contractor Signature Date • Permit Application Richard & Sharon Blaine 22284 N. Deanza Circle ` Cupertino, Ca 95014 Suitable Mounting Location of Solar Array 4 • 19 total PV panels to be mounted on UniRac SolarMount aluminum roof racks. Racks are to be grounded. (See attached Unirac data sheets) • Standoffs for racks to be lag-screwed to rafters with 5/16" x 3 1/2' stainless steel lag screws every 4' -6' typically and sealed with long-life polyurethane, and flashed. Panels to be flush mounted on roof. • Inverters to be mounted under modules,one per module. • Roof loading to be less than 3.51bs. per sq. ft. and less than 351bs. per support poinP • All electrical work will be performed by a licensed contractor and in conformance W.% 005 NEC. SHEET PAGE %r Lj Title Page 1 � �� Site Plan ` �D 2 � - •-�.1 Grid Tie Plan Y 3 .: -�. Attachment Detail GPI 4 C 'System Specs p,PR 1 2� 5 C) - �`•� ��. Module Cut Sheet . 6 C) "Enphase Microinverter Cut Sheet $Y' 7 CIO UniRac SolarMount Cut Sheet 8-10 , C) QuickMount Cut Sheet 11 Permit Application -1- REGRID POWER, INUREAL GOODS SOLAR 22284 N. Deanza Circle ' Cupertino,Ca 95014 COMMENTS/NOTES: WOOD SHAKE ROOF SINGLE LAYER _ ---- tR_ 180 PITCH - - CIRCUE -, - NZ N DEA _ tJ _ Z ,rnq APPROVED 2 IN ACCORDANCE WITH THE CITY OF A�R 2 CUPERTINO CODES ANDORDINANCES _ SERVICE ENTRANCE DATE ) ` AND LOAD CENTER s4GNED , S U N RU N MET . - This set of plans a if lions M T Z r,7 be kept on the at I times and it uttlaavvfuI to any cha ions SUB PANE L on same%v t writtet rom the Buildin Department City of Cu The st of this pla and etionon9 NOT be held to ermif or t be an "P vat of the vioiatior of any pr visions • Of any City Ordman w. - �-1 t --/-•/-- REV 1 NOTES DATE INIT AWING TITLE 00 ' / PV ROOF PLAN 18" min. [� UNIRAC RAIL PROJECT NAME I ADDRESS e Ea QUICKMOUNT co Richard&Sharon Blaine 7(1 i 22284 N. Deanza Circle 3' Cupertino,Ca 95014 i 1k' I- A I GOODS (2) AC Disconnects (Leviton or Equiv.) LU SOLAR Located on Roof One Enphase � � 1624 DELL AVE. Microinverter Per Module 19 SOLAR MODULES CAMPBELL, CA95008 PHONE: (408)370-3600 PROPOSED AT THIS LOCATION �� www.regrid.com Y DRAFTER K. HAUGEN DATE PAGE 1 04/12/10 SCALE SI]1� ' 0 1 = 10' 1----3 1 FILE NAME SITE PLAN—BLAINE DWG.NO. APP 4911 INVERTERS DC Source Circuit (for Each PV Module) COMMENTS/NOTES: PHOTOVOLTAIC POWER SOURCE DC RATINGS: "ALL INVERTER OUTPUT CIRCUITS MAX INPUT V: 54V MAX POWER OUTPUT I: 0.80A ARE 15A 7.67 Amps MAX INPUT I : 10A MAX POWER OUTPUT V: 240/120 - OPERATING DC CURRENT: Added SunRun Meter for Monitoring OF;0 1 OPERATING DC VOLTAGE: �30.0 Volts MAX.SYSTEM DC VOLTAGE: 41.8 Volts SHORT CIRCUIT DC CURRENT: 8.40 Amps J REVISION APPROVED IN ACCORDAN E wITH THE CITY Of CUPERTINO COpEVA�.RDI � • S. ` DATE ' SIGNED Lrv— wns MUST _ $ Ian and spec Q This set th job at all times and it is /6\ tz N L1 e any changes o►alterations -C. c, - uMawful to mak t written Pe►m on from - - - 4 - sai penino. - - + - �Wbiryg Department,C Ica{ions 1 i stamPm9 o this plan an spec ig - _ T be held to permit or to be an - - i ` 1 - - vat the violation of anY Provisions - 1 } L]I o �r State law. L1 -1 - — \�/) M - { r 1 Lz Lz uerE2_ z 4IN, - N N -- -- - - �I 3cxouxo GROUND L:�lv xo � � NO. REV/NOTES DATE INIT 4 --� ROUND _ CT�j+-v�� + DRAWING TITLE r I � MAY 212010 11 PV ROOF PLAN � METER , Note B . 2�� ,,,/ �r Ground Fault Protection provided in inverters; DC/AC Grid Intertie Inverters are Enphase series listed to UL- 1741 "Utility interactive" UTILITY LINE IN PROJECT NAME/ADDRESS Richard&Sharon Blaine O EQUIPMENT SCHEDULE WIRE SCHEDULE 22284 N. Deanza Circle Cupertino,Ca 95014 TAG DESCRIPTION PART NUMBER NOTES TAG DESCRIPTION WIRE NO. OF CONDUIT CONDUIT -- - - - - — - i GAUGE CONDUCTORS TYPE SIZE 1 -- -� 1 Solar Array (19) Sharp NU-U230F3 STC=230W, PTC=207. W I- - 3 XHHW-2 #14 AWG 3 Factory Bundled WA 2 Inverter (19)Enphase M190-72-240--SO1/2 2 circuits, 10 and 9 inverters 4 Solid Copper Ground #8 AWIG 1 N/A WA 5 AC Disconnect Switch Leviton 1202-2 or equivalent Labeled as per NEC 690-17 $ THWN-2 #10AWG 3 EMT 3/4" r+`~ 2p, 120/277V tL percircuit - I. LA L GOODS 8 SubPanel Rated 100A, 240VAC abeled as per NEC 690-17 Combined Equipment O E ,; 7 Ground and grounding #6 AWG 1 EMT 3/4" 1624 DELL AVE 9 Breaker for Subpanel 20A electrode conductor CAMPBELL,CA95008 — �— PHONE:(408)370-3600 10 Main Service Panel Rated 125A, 240VAC Labeled as per NEC 690-54 8 THWN-2 #10 AWG 3 CA Lic#865730 &690-56 www.RealGoodsSolar.com i 11 Ground Rod Existing Ufer DRAFTER — K. Haugen 12 Solar Breaker (2) 15A _ DATE PAGE 13 Main Breaker 125A 04/08/10 n 14 SunRun Meter Single Phase N/A Srg - 3 - - - — RILE NAME Copyright c 2010 by Real Goods Solar,Inc SITE PLANBLANNE All right reserved.Proprietary information DWG,IN AFF. - - - - -- which may not be reproduced,disclosed, or redistributed without permission 4911 . � �_ INVERTERS COMMENTS/NOTES: DC Source Circuit(for Each PV Module) MAX INPUT V: 54V MAX POWER OUTPUT I: 0.80A PHOTOVOLTAIC POWER SOU ALL INVERTER OUTPUT CIRCUITS SOURCE DC RATINGS: " ARE 15A MAX INPUT I : 10A MAX POWER OUTPUT V: 240/120 OPERATING DC CURRENT: 7.67 ps — I OPERATING DC VOLTAGE: 30.01 Volts MAX. SYSTEM DC VOLTAGE: 41 6 Volts SHORT CIRCUIT DC CURRENT: 8.40 Amps P C�I •I� -- ----- APR 12 2414 0 2t. L1J L2 N Ll 8 �� A + + 5 1 _ Cj3 1 / � O; Ll L1 .\ Li — 2 REV/NOTES DATE INIT �J N N N L•-------- --------------1-------- --------------- - -- NEUTRAL � 84G TITLE GROUND 1 GROUND 4 GROUND -- .� PV ROOF PLAN -- - L! I 11 '� Note 7 — METER PROJECT NAME/ADDRESS Ground Fault Protection provided in inverters; DC/AC Grid Intertie Inverters are Enphase series listed to UL- Richard&Sharon Blaine 1741 "Utility interactive" LINE IN 22284 N. Deanza Circle Cupertino,Ca 95014 O EQUIPMENT SCHEDULE — WIRE SCHEDULE TAG DESCRIPTION PART NUMBER NOTES TAG T DESCRIPTION WIRE I NO. OF CONDUIT CONDUIT LLM — ----- - - GAUGE CONDUCTORS TYPE SIZE 1 Solar Array (19)Sharp NU-U230F3 STC=230W, PTC=207.1 W --- _ 3 � XHHW-2 #14 AWG 3 Factory Bundled N/A 2 Inverter (19) Enphase M190-72-240-S01/2 2 circuits, 10 and 9 inverters 4 Solid Copper Ground #8AWG 1 N/A N/A a_ R EA L GOODS Leviton 1202-2 or equivalent Labelers as per NEC 690-17 6 THWN-2 #10 AWG 3 L EMT 3/4" LL, S I^' i 5 AC Disconnect Switch 2p, 120/277V 1 per CIrCUIt — 1624 DELL AVE. Combiners Equipment CAMPBELL,CA95008 8 SubPanel - Rater! 100A, 240VAC — — Labelers as per NEC 690-17 7 Ground and grounding #8 AWG 1 EMT 3/4" PHONE: uc assa30�0 3soo 9 Breaker for Subpanel 20A electrode conductor www.RealGoodsSolar.com ar.com�— _ 10 Main Service Panel Raters 125A, 240VAC Labelers as per NEC 690-54 g THWN-2 #10 AWG � 3 � _J�_ DRAFTER &690-56 _ — K. Haugen 11 Ground Rod Existing Ufer DATE PA 12 Solar Breaker (2) 15A SCALE /10 � SCALE SIZE -- - — ---- N/A B 3 13 1 Main Breaker 125A FILENAME -- — Copyright©2010 by Real Goods Solar,Inc SI-fE PLAN-BLAINE All right reserved.Proprietary information DWG.No. APP. which may not be reproduced,disclosed, 4911 or redistributed wnthout rmission. COMMENTS/NOTES: G� � EMI INSTALLATION ORDER UNIRAC SOLAR RAIL 1 LOCATE RAFTER.MARK HOLE LOCATION 5115HEXNUT ANDDRILLPILOTHOLE. 2.SEAL PILOT HOLE VMTN POLYURETHANE SEALANT 3.SLIDE OM UNDER SHINGLES AND LAG HAN BOL T THRU OM FLASHING INTO RAFTER. L-FOOT ATTACHED- - 4.TIGHTEN L-FOOT ONTO OM BLOCK 4 HANGER BOLT SEATED INTO OM 48"-72"Between Footings OM FLASHING UNDER- SHINGLE 2 3 (E)ROOF COVERING � "y IN ;REV/NOTES DATE INIT — (E)ROOF DECKING 24 RA TITLE (E)2 x 6 Rafters @ 24"OC Max Unsupported Span 10'-9" (E)RAFTER I0- STANDOFF AND 5116"DIA LAG BOLT � ROOF PLANE DETAILS (2-1/2"EMBED,MIN) .. — JECT NAME/ADDRESS FRONT VIEW OF ROOF PLANE QUICKMOUNT Richard&Sharon Blaine 22284 N.Deana Cirde _ Cupertino,Ca 95014 4� R I- A I- GOODS LU SOLAR :- 1624 DELL AVE. CAMPBELL, CA 95008 PHONE: (408)370-3600 www.realgoods.com DRAFTER K. HAUGEN LAST REVISION PAGE 04/12/10 SCALE Size NOT TO SCALE g 3 FILE NAME STANDOFF-ROOFPLANES Permit Application Information for Photovoltaic Solar Electric System R R Property Owner Name Richard & Sharon Blaine Installation Address 22284 N. Deanza Circle Cupertino, CA 95014 Phone (408) 257-6410 1 To v3.95.4A Seller Company Regrid Power, Inc., 1624 Dell Ave., Campbell, CA, 950C6Zenn %i Contractor's License No. #865730 C-46 solar, C-10 electrical, B general builder,A 4 Contractor's Bond No. 1040934 Surety Company of the Pacific eff.A14/:� Workers Compensation C20090687502 I Majestic Insurance Company I eff. 6/1/2009 Contact/Applicant Kara Haugen $Y:_ Phone Numbers 408-370-3600 (main) or 408-410-2964 (mobile) Project Description 3,496W Grid-Tied Solar Electric System including the following components: Photovoltaic Modules(Panels) 19 Sharp NU-U230F3 PV Panels Inverter 19 EnPhase Inverters M190-72-240-S0112 AC Disconnect Switch 2 Leviton 1202-2 or Equiv. C Disconnect Switch 0 Mounting Racks Roof UniRac SolarMount racking components PV Panel Specifications System Specifications Solar Panel Type NU-U230F3 Total Number of Solar Panels 19 Load Current(Imp) 7.67A Short Circuit Current Isc 8.40A STC Wafts Produced by Array 4,370W Load Voltage(Vmp) 30.OV PTC Wafts Produced by Array& Inverter 3,496W Open Circuit Voltage Voc 37.OV Array Width 23.3' Watts per Panel(at STC) 230.OW Array Depth 16.6' Wafts per Panel at PTC 207.1W Array Weight(including racks) 826.1 lbs. Panel Width 39.1 Panels& Mounts Load Concentration 3.1 lbs./sq. Panel Length 64.6" Dead Load per Support Point 25.0 lbs. Individual Panel Weight 46.3 lbs. Panel Dead Load Concentration 2.5lbs./s .ft. 19 inverters Total, Max 15 per Circuit Inverters to Subpanel AC HHN/THWN-2 Cable in conduit #12 AWG Working Voltage 240VAC Temp. Derated Ampacity of Cable 17.04A NEC Required Cable Ampacity 9.13A Overcurrent Protection(AC breakers) 15A Max. System Voltage Calculations DC Equipment-Grounding Conductor #J8 AWG LRokvest Ambient Temperature for Site 230 F fa1k ed by Array(Voc) 37.OV Grounding Electrode Conductor LaW p I e uitiplier(per NEC) 1.13 to to e t mp 41.8V -Ali •x �•,' UO &,90 NO/V �� !'t . SHARP _ ,: ,• solar electricity Sharp's highest-power residential 230 WATT solar module makes a beautiful addition to nearly any roof. RESIDENTIAL MODULE NEC 2008 Compliant _ ENGINEERING EXCELLENCE NU-U230173 is the perfect combination Zof high-performance and design. �p; ADVANCED AESTHETICS CD 111 'r Sleek,black frame module provides an elegant u, 0 appearance that blends beautifully with your home's rooFline. NJ DURABLE (��I �� Tempered glass,Eiehi3trod l� {} weatherproof backskin pr V lTtli?W1 i " enhanced cell performance r F-- _RELIABLE. �Y ti25-year limited warranty on power output. Cn HIGH PERFORMANCE This module uses an advanced surface Wcrnn "r� texturing process to increase light absorption LU and improve efficiency. NU-U230F3 -Avow RESIDENTIAL 230 WATT - MODULE FROM THE WORLD'S TRUSTED SOURCE FOR SOLA Our most powerful residential module { manufactured today, the NU-U230F3 bler9sE S high performance with advanced solar aesthetics. Black backsheet and sleek blacam*) ►' frame create a modern silhouette on nea Blac:kfrarneimprovesatWhetics _ Lamina tetlylasscanstrtrction for residential roof top applications. to a high torsion frame. _ roof. Using breakthrough technology, maLZ possible by nearly 50 years of proprietar research and development, this module SHARP:THE NAME TO TRUST When you choose Sharp,you get more than incorporates an advanced surface texturin well-engineered products.You alsoget5harpA, process to increase light absorption and proven reliabillity,outstanding CustomerserViceand improve efficiency. Flexible enough to permit the assurancFof our 25-yela•limitedwarrantyon installation on nearly any kind of roof, the 230 power output.Ag3obal leader inso[arelectridittr, Sharp powers.r0ofahomes and.businesses than ' watt module is the newest innovation in Sharp's any,other solarmanufacturerWorldwide. '. residential product offerings. BECOME POWERFUL �ykfrl 4i�230 WATT y NU-U230F3 NEC 2008 Compliant Module output cables 12 AWG with locking connectors ELECTRICAL CHARACTERISTICS IV CURVES Maximum Power(Pmax)' 230 W CollTemperatu 25•c Tolerance of Pmax +10%/-5% t Type of Cell Monocrystalline silicon Cell Configuration 60 in series Open Circuit Voltage(Voc) 37.0 V Maximum Power Voltage(Vpm) 30.0 V Short Circuit Current(Isc) 8.40 A € Maximum Power Current(Ipm) 7,67 A I Module Efficiency(%) 14.1% Maximum System(DC)Voltage 600 V I.- Series Fuse Rating 15 A NOCT 47.5°C — - — Temperature Coefficient(Pmax) -0.485%/°C ie i, m n e v Temperature Coefficient(Voc) -0.351%/°C voltagetvl _c.-.-vxiarN Temperature Coefficient(Isc) 0.053%/°C Current.Power n Voltage Orancterklics eawm Witage 'Measured at(STC)Standard Test Conditions:25'C,1 kw/m'insolatlon,AM 1.5 MECHANICAL CHARACTERISTICS DIMENSIONS ¢, Dimensions(A x 8 x C below) 39.1"x 64.6"x 1.8"/994 x 1640 x 46 mm BACK VIEW - Cable Length(1) 43.3"/1100 mm I A SIDE VIEW Output Interconnect Cable" 12 AWG with MC4 Locking Connector 1 Weight 44.1 Ibs/20.0 kg ° & 0 r E _t T Max Load 50 psf(2400 Pascals) Operating Temperature(cell) -40 to 194°F/-40 to 90'C — F I "A safety lock clip(Multi Contact part number PV-SSH4)may be required in readily accessible locations per NEC 2008 690.33(C) --AV-- QUALIFICATIONS — (-)� �(+) — e UL Listed UL 1703 Fire Rating Class C c �L us F (10)d0.35'9 mm WARRANTY 7 25-year limited warranty on power output 00A7•14.3 mm .r E Contact Sharp for complete warranty information j ° I Design and specifications are sub•ect to change without notice. T f H �I ^-I F^c Sharp is a registered trademark of Sharp Corporation.All other trademarks are property of A B C D E their respective owners.Contact Sharp to obtain the latest product manuals before using any Sharp device. 39.1"/994 mm 64.6-/1640 mm 1,8"/46 mm 7.9"/200 mm 14.47365 mm F G H I 32.3"/820 mm 3.9"/100 mm 37.7"/958 mm 43.3"/1100 mm Contact Sharp for tolerance specifications SHARP SHARP ELECTRONICS CORPORATION 5901 B01sa Avenue,Huntington Beach,CA 92647 1-800-SOLAR-06-Email:sharpsolar@sharpusa.com www.sharpusa.com/solar ID 2009 Sharp Electronics Corporation All rights reserved 09F 040•PC-06.09 C ENPHASE NIICRO - INVERTER ,1 ry The Enphase Energy Micro-Inverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the micro-inverter, the Envoy Communications Gateway, and the web-based Enlighten monitoring and analysis website. - Maximum energy production P R o o u c T i v E - Resilient to dust, debris and shading - Performance monitoring per module - MTBF of 365 years RELIABLE - System availability greater than 99.8% - No single point of system failure s M a R T - Quick & simple design, installation and management - 24/7 monitoring and analysis CO c us MICRO-INVERTER TECHNICAL DATA and 72 Cell Modules Input Data (DC) M190-72-20B-SM/2 M190-72-240-so112 Recommended input power(STC) 230W 230W Maximum input DC voltage 54V 54V 1 Peak power tracking voltage 22V-40V 22V- 40V Max. DC short circuit current 12A 12A Max. input current 10A 10A Output: Data (AC) Maximum output power 190W 190W Nominal output current 920mA 800mA Nominal voltage/range 208V/183V-229V 240W211 V-264V Extended voltage/range 208V/179V-232V 240V/206V-269V Nominal Frequency/range 60.0/59.3-60.5 60.0/59.3-60.5 Extended Frequency/range 60.0/59.2-60.6 60.0/59,2-60.6 Power factor >0.95 >0.95 Maximum units per branch 21 15 Efficiency Peak inverter efficiency 95.5% 95.5% CEC weighted efficiency 95.0% 95.0% Nominal MPP tracking 99.6% 99.6% Mechanical Data Operating temperature range -40°C to +65°C -400C to +65°C Night time power consumption 30mW 30mW Dimensions(WxHxD) 8" x 5.25" x 1.25" Weight 4.0 Ibs Cooling Natural Convection- No Fans Enclosure environmental rating Outdoor- NEMA 6 Features Communication Powerline Warranty 15 Years Compliance UL1741/IEEE1547 Pending FCC Part 15 Class B Pending Enphase Energy, Inc. 142-00005 REV 01 201 1st Street, Suite 300, Petaluma, CA 94952 877 797 4743 enphaseenergy.com ® Printed on 100 percent recycled paper. THE STANDARD IN PV MOUNTING .STRUCTURES'" www.unirac.com SolarMount is much more than a product. It's a system of engineered components that can be assembled into a wide variety of PV mounting structures.With SolarMount you'll be able to solve LLIE, virtually any PV module mounting challenge. It's also a system of technical support: complete installation and code compliance documentation, an on-line SolarMount Estimator, person-to-person customer service, and design assistance to help you sMlpe toughest challenges. �NNWich is why SolarMount is PV's most widely used jVy ing system. PQ��� U.S.Des.Patent Nos.D496,248S,D496,249S.Other patents pending. L Three great innovations / mounting better thon ever44 i Oe UniRac Grounding Clip SolarMount®Light Save time and materials by eliminating the Lower-cost SolarMount Light rail employs 38 need to tediously install a grounding lug on percent less aluminum than standard rail, each module and bare copper wire between yet it's more than strong enough for flush all modules.Instead,simply press one of applications.Use the same installer-friendly these clips into the top slot of the SolarMount top mounting clamps and footing components rail at the end of the row and between each that work with SolarMount standard rail. pair of modules as they are installed.Align and fasten the modules with SolarMount top mounting clamps in the usual manner.The SolarMount®Ballast Frame nibs of the UniRac Grounding Clip pierce the The SolarMount system is more flexible than anodizing as the mounting nuts are tightened, ever with the introduction of a ballast frame, thus creating a ground path through the in most cases requiring no penetrations SolarMount rail.Complete the installation by whatsoever.Learn more from our data sheet installing one grounding lug at the end of the SolarMount Modular PV Ballast Frame, SolarMount rail. Connect the lugs with a bare which you can download at www.unirac.com. copper wire to ground the entire array. M -IP3 5olarMounte Rail Options lrry fl,em-vamt,y riiil;,da" the Sol.11-Mounl:ILMir,tr180 irs IN I'oIe7nps iz-,U I,As(see l�- sepnrme dma sheeis),and cusion,applications[lust -� require ianti spans. _, Standard rail gives you ultin,.nc flexibility,including _ bouorn mntnuing and tilt up options, ... In slush mounted atrr.ivti Cas hti handling SolarMount& - � Light rail S"wes.ilu ill innm nrld expense wit hoot rntnpromising siructunil integrity. • i. k.. r y i ModuleI • LAMM LL : ■ Bottom mounting:Preassemble full rows before final installation(standard and HD rail only). Top Mounting Clamps Bottom Mounting Clips Junction Plates SolarMount Use bottom In shared-rail T-bolts quickly mounting clips configurations mount your (standard and (standard and modules to any HD rail only) HD rail only), SolarMount rail whenever you attach modules 1 from the top. prefer to attach with four-slot i This is ideal for rails directly junction plates. i flush mount to the module North-south applications, mounting slots secure such as holes.Simply the rail to residential rooftops,where it fit the clip into its rail slot over the plates.East-west slots secure a is most convenient to secure the mounting bolt for a secure module on each side of the rail. footings and rails before connection.Adjust the clip installing modules.Clamps position anywhere along the rail securely grip any point of slot.Alignment of rails to module the module frame,freeing j mounting holes is always easy and you from the constraints of convenient. module mounting holes. r--boh System Faat�ng 5erure fanlings€x11t yuirkl� ;}nd Basil}•to I�Inting ball lints in cln�-SolnrMaunt� rail. Use st�tnduffs n�llr:�ne�rr f1�7shed irlst.11ltltir�ns 5tttnd�lra fur grsnlnLl n3[�unl a1r�.inquired,on tile•rtlnfs,fcrr esrin7Rle. inst�.11l�ttinns,L Fcet rtlount 1'4vn-i3iecre 111i1711i1t][77 slandnll al€L74V�rl'CkSf rails t❑residential and l3laretllenl of.1 Iluslling n4cr i.l secured lrlsc cat7u77crri.11 rnLll'tnps as prksr to I he insttllltltiorl of the stnndUff itself. ivcll. Lfse thes7l rllanc ab[3vc Strut-in-Tube Style Legs Ali S1:11lifUfl 1V13L'S C[)iitC Ili fotll'Si FillLlt71'd asRll[il[cnmpasi[inn shingles �_oot heights:;�,q,h,trod 7 inches.Rllilruprialtr or in rr3njunetion 4vith flat u3fr f flashitlgs art'av�liiahle. standoffs. Rail mnLrluirlg holes t71'L�to 1�4•u heights. [n hush mounts,use the u1313e1•hole to mist the tnoLiules[1[1L€17COt33UiC III'f1U14 Y � fol'L'OC]ilI]�,.LNltc'l e�1L'S111Ct1C$:ll'E[l7L�,!'L'aiC1' a concern,use the In�•cr hole ui keep the mcicltklcs close to the°k'ur�l�. �fwo-prcrc orumrnun[ Steel ra�srd Srrcl(IQc cop �Inr tap plunge Quickly Styles are available for high profile(I or 2 -1 legs per rail)and low profile installations. Each series offers three leg lengths so IN Low profile that you can adjust to exactly the tilt angle you • to. maximum LOW pr of 61 • • and drilling at the job site. Strut-in--tube leg H High profile �ti Start at www.unirac.com Download our SolarMount®Master Price List with Suing Charts and installation manuals.Generate quick price estimates with our on-line SolarMount®Estimator. Y- Code Compliant Warranty The SolarMount®system is PE certified.Call UniRac SolarMount®is covered by a 10-year limited product for documentation applicable to your building code. warranty and a 5-year limited finish warranty.For complete warranties,download any SolarMount® Component Specifications installation manual from our web site. 6061-T6 and 6063-T5 • SolarMount ballast frame ................................................................... 6105-T5 aluminum extrusion • SolarMount®rails • Mounting clips and clamps • Tilt legs and L-feet • two-piece standoffs Severe Condition 4(very severe)zinc-plated welded steel • One-piece standoffs 18-8 stainless steel • Fasteners ........................................................................ THE STANDARD IN PV MOUNTING STRUCTURES'" Pub 060901-1ds • October2006 1411 Broadway NE, Albuquerque NM 87102-1545 USA 0 2006 UniRac,Inc.All rights reserved. OluickMount • SPECIFICATION SHEET QuickMount PV TM is an all-in-one waterproof flashing and mount to anchor photovoltaic racking systems to a new or existing roof. It is made in the USA of aluminum and includes stainless steel hardware. It works with all standard racks, installs seamlessly and is a better low-profile mount. • (2) • Hex Nuts Flat Washer (B) 1" x 5/16" 5/16" Rubber Gasket 60 Durometer EPDM Sealing Washer (A) 3/4"x 5/16" Hanger Bolt 5/16" x 6" ' 1-1/2" Machine, 1-1/2" Spacer, 3" Lag Mount & Flashing Aluminum Mount 2-1/4"1 x 1-1/4"w x 1-1/4"h Flashing .05" thick. For standard composition roofs: flashing is 12" x 12", mount is attached 3" off center. For high definition cut composition, or shake roofs: flashing is 18" x 18", mount is attached -�- 3" off center. For flat applied roofing during Patent Pending installation of roof: flashing is 18" x 18", mount is attached in the center. Lag pull-out (withdrawal) capacities (lbs) in typical lumber: Lag screw specifications Specific 5/16"shaft* 5/16"shaft* gravity 3"thread depth per 1"thread depth Douglas Fir, Larch .50 798 266 Douglas Fir, South .46 705 235 Engelmann Spruce, Lodgepole Pine (MSR 1650 f&higher) .46 705 235 Hem, Fir .43 636 212 Hem, Fir. (North) .46 705 235 Southern Pine .55 921 307 Spruce, Pine, Fir .42 615 205 Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources: Uniform Building Code;American Wood Council Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2)Pull-out values incorporate a 1.6 safety factor recommended by the American Wood Council. 3)See UBC for required edge distances. *Use flat washers with lag srews. 12-2006[SPECSHT] 108 Crest Avenue — Alamo, CA 94507-2646 Toll Free: (800) 998-6059 Phone: (925) 935-7811 Fax: (925) 935-7877 Email: info@-guickrackpv.com www.quickrackpv.com