Loading...
approved plans_R-2020-015 Community Development Department Planning Division — Cupertino CUPERTIN4 APPROVED Case # -2020-015 Ap)lication Number(s) �S�p ARC/y/T Approval Body: Director/Staff \c,F ss E. Lo,,G Approval Date 1 /19/20 T H E C O U R T I E R L U R E S I D E N C E v �-o //" Signature Ellen tau 1 0490 W U N D E R L I C H D RIV E C UP E R TIN 0 C A 9501 4 C-28651 Case Manager �-q� ReN• 10.3A tit \� OF CALXF STAINED WOOD SMOOTH INTEGRAL WOOD ENTRY DOOR FIBERGLASS WINDOWS STAINED CEDAR EAVES PAINTED METAL TRIM ISSUE DATE FA PLANS V1 112019 SIDING COLOR STUCCO SIMPSON DOORS MARVIN INTEGRITY AND FASCIA FA DRAWINGS V1 121919 (LIGHT GRAY) (DARK BRONZE COLOR) PLAN UPDATES 02 50% DESIGN SET V1 022220 2220 50% DESIGN SET V2 041420 RPM PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 Ir I -- — ARCHITECT ,to � x 0 = zU Q � QO O � m * CD La CO mo Cl) rn I-- Lu Ln c Z) o z � _k sLu Lu g : . V U) z Qo 4 � m Lfl O _. MODULAR FABRICATOR v + r APPROVALSTAMP IL pp— i I i r - - THE COURTIER LU RESIDENCE 10490 WUNDERLICH DRIVE CUPERTINO CA 95014 APN: 375-17-055 COVER AND MATERIALS THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN - _ l _ - _ J ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE _•• - - _ - - - - i _ .*- - - - }Ai�1' --3`-y --�' ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING '- THEEXPRESS WRITTEN PERMISSION OF tobylongdesign = r scale AS NOTED sheet a prefab construction project in cupertino, ca A 0 . 0 1 CONCEPT RENDERING / MATERIALS OC TOBYLONGDESIGN 2020 Community Development Department Planning Division - Cupertino CUPERTINO APPROVED Case# -2020-015 AID Acation Number(s) SED ARC Y/T, Approva I Body: Director/Staff mac, ss E. LONE �� Approva I Date 1 /19/20 T H E C O U R T I E R L U R E S I D E N C E v �° Signature Ellen lau 1 0 4 9 0 W U N D E R L I C H D R I V E C U P E R T IN 0 C A 9 5 0 1 4 c-28651 Case Manager ���, �FN• 10.3A tit �\7 OF CA 1: FRONT OF HOUSE CAL GREEN COMPLIANCE O F F I C E O F C O U N T Y ASSESSOR S A N T A C L A R A C O U N T Y, C A L I F O R N I A 375 1A7 A)WATER CLOSETS. THE EFFECTIVE FLUSH VOLUME OF ALL WATER CLOSETS SHALL NOT EXCEED 1.28 ISSUE DATE GALLONS PER FLUSH. TANK-TYPE WATER CLOSETS SHALL BE CERTIFIED TO THE PERFORMANCE o FA PLANS V1 112019 CRITERIA OF THE US EPA WATERSENSE SPECIFICATION FOR TANK-TYPE TOILETS. II FA DRAWINGS V1 121919 B)SINGLE SHOWERHEAD. SHOWERHEADS SHALL HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 PLAN UPDATES 022220 50%DESIGN SET V1 022220 GALLONS PER MINUTE AT 80 PSI. SHOWERHEADS SHALL BE CERTIFIED TO THE PERFORMANCE CRITERIA 2s 50% DESIGN SET V2 041420 OF THE US EPA WATERSENSE SPECIFICATION FOR SHOWERHEADS. PLANNING SUBMITTAL V1 052920 -�JOHNSON - .AVE. PLANNING SUBMITTAL REV1 080720 TRACT N° 1183 C) MULTIPLE SHOWERHEADS SERVING ONE SHOWER. WHEN A SHOWER IS SERVED BY MORE THAN ONE 'I'D 5'°°D 3A.83," PLANNING SUBMITTAL REV2 092420 - �_ 35 SHOWERHEAD, THE COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS 44-M-11 w > �1 ' 48�.; CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 2.0 GALLONS PER MINUTE AT 80 PSI, OR THE a 45 of 4s j 47 1&m w d SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWER OUTLET TO BE IN OPERATION AT A TIME. m 5 29 ' 29 27 55 05 5512 Q NOTE:A HAND-HELD SHOWER SHALL BE CONSIDERED A SHOWERHEAD. Z o$ aa5„�261±9 18 p --110.16 _ _1054 D) RESIDENTIAL LAVATORY FAUCETS.THE MAXIMUM FLOW RATE OF RESIDENTIAL LAVATORY FAUCETS ..a°'�^ 43 174„ 25 50I ARCHITECT TRACT N" 1004 106_49 SHALL NOT EXCEED 1.5 GALLONS PER MINUTE AT 60 PSI. THE MINIMUM FLOW RATE OF RESIDENTIAL 40-M-29 C.L.M.23139787 o 7,748,f- 112 y I LAVATORY FAUCETS SHALL NOT BE LESS THAN 0.8 GALLONS PER MINUTE AT 20 PSI. ---� CALVERT 4 R.O.S.840 1e DRIVE -�- ery ; 42 175 Nst24 51 O -0155 1030 03 /OffS 1-1 /0345 /0355 /03J3 10315 /OSBS 315 1405 /041 O-- 52.25 10522 Z 40 57 l 51.1851 s75 51.19 1 57 1 sLlB 57 I I.18 1 s7 1 51.18 /Os7 5115 52.6a,m 71z - 403'g176 �+, PCL. A 58 Q E) KITCHEN FAUCETS. THE MAXIMUM FLOW RATE OF KITCHEN FAUCETS SHALL NOT EXCEED 1.8 3D�a w I 1 I a1 ao s n5a9_ 019"° 26 m a ry v � 17 h 18 i 19 20 121 1 22 23 24 1 251 28 127 28 129;J 30 31 - =J \ GALLONS PER MINUTE AT 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE FLOW ABOVE 4e ;° 147 146 i las ,,, I la3 142 141 „° 139 36 37 36 I 135�-I 134 32 / 39 177 N ' j 22 56 a m �J / Q 2 THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE AT 60 PSI,AND MUST DEFAULT TO A _ 1 �_ L__�__�__ L _ L_r�_�l SLITS 32g7 / 133 yo/ 's", 60$eYr 10831 �.. _ _ Q z (� Q T__�__�___ _ ,�__�_-T T - k / 33 N 11123 J.x 15 = S II6 117 I IIB I 119 1 120 l 121 22 123 124 125 26 1 127 1 128 1 129� 11 S9 178 o M zl m O Q MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. O p5 0�umo _ 54 p e.. \ > Z ry n I,,, I I I I I 1 130 Y 132 6,169 f 05.36 / NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE,AERATORS OR OTHER MEANS MAY BE USED TO L ;�L5 14 j L3 t2 11 10 s e s 5 4 3 Pi ? ! 34o N '� N Y 0° ACHIEVE REDUCTION. w 3s ns N 5 t TRACT N°wsa Qp 57 51.18 57 51.18 57 51.IB 51.18 51.18 51.18 51.18 51.18 51.18 51.15 50 /92.20 55 ro454 10490 42-M-24 O r a69t /0f 90 /0300 /03/C /03f0 /0330 /0340 /03J /036 3)O 3 0900 /04/O /09P0 0430 WUNDERLICH - - -- DRIV N F)STANDARDS FOR PLUMBING FIXTURES AND FITTINGS. PLUMBING FIXTURES AND FITTINGS REQUIRED fD to o IN SECTION 4.303.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE,AND Z `r' CO ow x 0� SHALL MEET THE APPLICABLE REFERENCED STANDARDS. 16 I L Lu to Q Z) 0 G) IRRIGATION CONTROLLERS. AUTOMATIC IRRIGATION SYSTEMS CONTROLLERS INSTALLED AT THE w ----------- TIME OF FINAL INSPECTION SHALL BE WEATHER OR SOIL MOISTURE-BASED. > -t Q 1 H)OPERATION AND MAINTENANCE MANUAL. AT THE TIME OF FINAL INSPECTION,A MANUAL, COMPACT _A�ENeE E STONE ASSESSOR W DISC,WEB-BASED REFERENCE OR OTHER MEDIA ACCEPTABLE TO THE ENFORCING AGENCY WHICH L. Dadnetml mnp('uses T,C.d., S.,,32TWy. J Compiled under R.&T Code,Sec.327. J ERaetive Rdl A. 2019-2020 Q /r1 INCLUDES ALL OF THE FOLLOWING SHALL BE PLACED IN THE BUILDING: < z I)DIRECTIONS TO THE OWNER OR OCCUPANT THAT THE MANUAL SHALL REMAIN WITH THE Q O BUILDING THROUGHOUT THE LIFE CYCLE OF THE STRUCTURE. v } e p ° G2 1. v Q II CHT Construction OPERATION AND MAINTENANCE INSTRUCTIONS FOR THE FOLLOWING: - M f ��; co (1)EQUIPMENT AND APPLIANCES, INCLUDING WATER-SAVING DEVICES AND SYSTEMS, Ralya Ct x Q - pP/p REAR OF HOUSE HVAC SYSTEMS, WATER-HEATING SYSTEMS AND OTHER MAJOR APPLIANCES AND Richie Rich Mobile Ser�aF EQUIPMENT. n Mechanic/Southbay... s (2) ROOF AND YARD DRAINAGE, INCLUDING GUTTERS AND DOWNSPOUTS. Menh art Ln �aAa0 �- (3)SPACE CONDITIONING SYSTEMS, INCLUDING CONDENSERS AND AIR FILTERS. Runo rej\�A t t (4)LANDSCAPE IRRIGATION SYSTEMS. (5)WATER REUSE SYSTEMS. vvarsha's notary Services = MODULAR FABRICATOR III) INFORMATION FROM LOCAL UTILITY,WATER AND WASTE RECOVERY PROVIDERS ON METHODS 0 m TO FURTHER REDUCE RESOURCE CONSUMPTION, INCLUDING RECYCLE PROGRAMS AND LOCATIONS. g Tsukushi Daycare a a dN IV)PUBLIC TRANSPORTATION AND/OR CARPOOL OPTIONS AVAILABLE IN THE AREA. =- = Crabtree Ave d o � x \ z ° G2 V) EDUCATIONAL MATERIAL ON THE POSITIVE IMPACTS OF AN INTERIOR RELATIVE HUMIDITY . m BETWEEN 30-60 PERCENT AND WHAT METHODS AN OCCUPANT MAY USE TO MAINTAIN THE RELATIVE n Menhar[Ln y HUMIDITY LEVEL IN THAT RANGE. > m MedicusCt \ ° + r Westdale or VI) INFORMATION ABOUT WATER-CONSERVING LANDSCAPE AND IRRIGATION DESIGN AND SITEle %s ®Lodi Lits Baboyan CONTROLLERS WHICH CONSERVE WATER. Q AYe 4Ye Starrett Ct A to Z earning Kor VII) INSTRUCTIONS FOR MAINTAINING GUTTERS AND DOWNSPOUTS AND THE IMPORTANCE OF 10490 Wunderlich Drive �Mitty Way Mi[ty DIVERTING WATER AT LEAST 5 FEET AWAY FROM THE FOUNDATION. Barnhart Ave Sterlin I f Ra Barnhart Ave 9 Doyle Barnhart Ave .Barnhart Park Archbishop Mitty VIII) INFORMATION ON REQUIRED ROUTINE MAINTENANCE MEASURES, INCLUDING, BUT NOT RarnhartAve High School Queenof� LIMITED TO, CAULKING, PAINTING, GRADING AROUND THE BUILDING, ETC. _ APPROVAL STAMP ndergast Ave No IX) INFORMATION ABOUT STATE SOLAR ENERGY AND INCENTIVE PROGRAMS AVAILABLE. Pendergast Awe Pendergas Ave s X) A COPY OF ALL SPECIAL INSPECTION VERIFICATIONS REQUIRED BY THE ENFORCING AGENCY OR o n \ THIS CODE. Q w � v U Tuggle Ave oc �� m G2 e a 1) INSTALLER TRAINING. HVAC SYSTEM INSTALLERS ARE TRAINED AND CERTIFIED IN THE PROPER ycare INSTALLATION OF HVAC SYSTEMS. o o = Cynthia Ave to J)SPECIAL INSPECTION. SPECIAL INSPECTORS EMPLOYED BY THE ENFORCING AGENCY MUST BE rette or QUALIFIED AND ABLE TO DEMONSTRATE COMPETENCE IN THE DISCIPLINE THEY ARE INSPECTING. �° Forest View Dr p° Cmsford or Renter Way Chelmsford K) DOCUMENTATION. VERIFICATION OF COMPLIANCE WITH THIS CODE MAY INCLUDE CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS, BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY WHICH SHOW SUBSTANTIAL COMPLIANCE. 1 CONCEPTUAL RENDERINGS 2 CAL-GREEN BUILDING CODE COMPLIANCE 3 VICINITY MAP / PARCEL MAP ARCHITECTURAL STRUCTURAL - CONTINUED PROJECT DATA OWNER ARCHITECT STRUCTURAL TITLE 24 / MECHANICAL SURVEY X A-0.0 COVER AND MATERIALS X PROJECTINFO A-0.2 GENERALNOTTES THIS PROJECT CONSISTS OF THE REMOVAL OF EXISTING HOUSE REPLACED RODOLPHE COURTIER AND TOBY LONG DESIGN CIVIL ENGINEERING AND X A-0.5 MASSING DIAGRAMS AREA CALCULATIONS LOT COVERAGE CALCULATIONS WITH THE CONSTRUCTION OF A NEW SINGLE FAMILY HOME AND ATTACHED ANNE LU 6114 LA SALLE AVE#552 LAND SURVEYING THE COURTIER LU RESIDENCE X A-0.6 MODULAR DIAGRAMS 1025 PARK PLACE APT. 125 OAKLAND, CA 36660 NEWARK BLVD. SUITE C x A-0.7 STREET VIEW ELEVATIONS FIRST FLOOR 1,019 SQFT GARAGE SAN MATEO, CA 94611 NEWARK, CA 10490 WUNDERLICH DRIVE X 1 OF 1 SURVEY LOT SIZE: 5,399 SQ. FT 94403 94560 CUPERTINO CA X A-1.2 SITE PLAN SECOND FLOOR 959 SQFT X A-1.3 PRIVACY PROTECTION PLAN FLOOR AREA COVERAGE: T.415. 905. 9030 X1 95014 - A-2.0 FOUNDATION PLAN HOUSE SUBTOTAL 1,978 SQFT MAX ALLOWABLE: 2,429 SQ. FT=(5399 45%) 6 PROJECT DESCRIPTION T. 408.540.8645 (RODOLPHE) C. 510.333.3447 T. 510.579.6112 APN: 375-17-055 X A-2.1 LEVEL 1 PLAN PROPOSED:2,429 SQ.FT. X A-2.2 LEVEL 2 PLAN T. 408.540.8646 (ANNE) CONTACT:TOBY LONG,AIA F.510.991.8054 X A-2.3 ROOF PLAN GARAGE 451 SQFT E. RODOLPHE.000RTIER@GMAIL.COM E:TOBY@CHXTLD.COM CONTACT: WADE HAMMOND X A-2.4 LEVEL 1 RCP LOT COVERAGE: 2019 CA BUILDING CODE 2019 CA MECHANICAL CODE 2019 RESIDENTIAL CODE E. annelu@notallon.com E:WADE@WHLANDSURVEYOR.COM INFO X A-2.5 LEVEL 2RCP TOTALFLOORAREA 2,429SQFT MAX ALLOWABLE: 2,429 SQ.FT 2019 CA ENERGY CODE 2019 CA PLUMBING CODE X A-3.0 BUILDING SECTIONS (FLOOR AREA RATIO) (2,429.55 MAX) PROPOSED:2,268 SQFT. X A-4.0 EXTERIOR ELEVATIONS MECHANICAL 2019 CA GREEN CODE 2019 CA ELECTRICAL CODE X A-4.1 EXTERIOR ELEVATIONS ESTIMATED LANDSCAPE AREA: A-5.1 INTERIOR ELEVATIONS A-5.2 INTERIOR ELEVATIONS = 3,186 SQFT. THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR X A-6.0 DETAIL KEY/ASSEMBLY SECTION GEOTECH CIVIL LANDSCAPE MODULAR FABRICATOR GENERAL CONTRACTOR AND DIGITAL SIGNATURE. NUNLESS ATURETHEY BEAR THE ARCHITECT'S SEAL 7 CODE REFERENCE AND DIGITAL SIGNATURE TLD EXPRESSLY RESERVES A-6.1 DETAILS COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS A-6.2 DETAILS APN#: 375-17-055 TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE A-6.3 DETAILS PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE X A-7.0 DOOR SCHEDULE WINDOW Elev. NO. ASSIGNEDTO ANY THIRD PARTY,WITHOUT FIRST OBTAINING ZONING: R1-5 REVISION FLOOR/CEILING ELEVATION/ THEEXPRESS WRITTEN PERMISSION OF tobylongdesign X A-7.1 WINDOW SCHEDULE SCHEDULE Q FLR# 1 SECTION MURRAY ENGINEERS, INC VIT HANACEK ENGINEERING, INC. HWA LANDSCAPE ARCHITECTS FIDELITY BUILDERS. INC DISTINCT BUILDERS LANDSCAPE CONSTRUCTION TYPE TYPE V-B � REFERENCE REFERENCE � ASSEMBLY PLUMBING REFERENCE REFERENCE 935 FREMONT AVENUE 2912 VESSING RD. 762 ALTESSA DRIVE PO BOX 2706 201 ADA AVE X L-o COVER SHEET Sheet o. LOS ALTOS, CA PLEASANT HILL, CA BRENTWOOD, CALIFORNIA ALBANY, OR 97321 MOUNTAIN VIEW, CA 94043 scale X L-1 LAYOUT PLANS SITE DIMENSIONS 86.05'x 50.30'x 105.36'x 34.93 A6 N 94024 94523 94513 X L-2 PLANTING PLANS DOOR X L-3 DETAILS 5,399 SQFT ALIGN ELEVATION SITE AREA ALIGN FINISH X L-4 PLANTING SPEC. D-## SCHEDULE � SURFACES REFERENCE X 1-1 IRRIGATION PLANS PARKING 2 OFF-SITE SPACES REFERENCE A Detail No. T: 925.262.7401 T. 925.513.3091 T: 541.981.2259 T: 650.224-5127 SOLAR PHOTOVOLTAIC DETAIL T: 650.559.9980 CONTACT:VIT HANACEK, PE C. 925.383.5703 CONTACT: RANDY ROTHWEILER CONTACT: BOBBY GILSON X I-2 IRRIGATION DETAILS REFERENCE X 1-3 IRRIGATION DETAILS HEIGHT RESTRICTION 28'-0" ---� Plan No. A6 CONTACT: ANDREW D. MURRAY E:V.HANACEK@YAHOO.COM CONTACT: H. ROSS WELLS E:RROTHWEILER@FIDELITY-BUILDERS.NET E: BOBBY@DISTINCTBUILDERS.COM x 1-4 IRRIGATION DETAILS WALL I :Sheet No.X 1-5 IRRIGATION SPEC.&WATER USE E E: ROSS HWALAN DARCH.N E❑ I I 1 @ FIRE PROTECTION FRONT SETBACK 20'-0" FOR 1ST STORY/25'-0" FOR 2ND STORY # ASSEMBLY I A6 sheet CIVIL REFERENCE I I X C-1 GRADING DRAINAGE,/STORM WATER SIDE SETBACKS S-0"FOR 1ST STORY/12'-0"& 13'-0"W/ARCHITECTURAL REVIEW I I 0 . 1 X C-2 SITE ULTILITES PLAN ---_� Sheet No. X C-3 CIVIL DETAILS REAR SETBACK 20'-0" FOR 1 ST STORY/25'-0" FOR 2ND STORY X C-4 EROSION CONTROL PLAN/DETAILS OC TO BYLONGDESIGN 2020 4 1 TABLE OF CONTENTS 5 1 SITE AND BUILDING INFORMATION 8 SYMBOLS 9 1 CONTACT INFO Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap lication Number(s) ��SED ARC&/ Approval Body: Dir ctor/Staff �L ss e• `oNc Approval Date 1 /19/20 /11 Signature Ellen 4au C-28651 Case Manager 10.3A OF CAL1F0 ISSUE DATE FA PLANS V1 112019 FA DRAWINGS V1 121919 PLAN UPDATES 020720 50% DESIGN SET V1 022220 j50% DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 ARCHITECT Q X U � fn -- ---- J } - ---- - Q O --- -% O F- f6 Lo o %4— Lo CO L w Lri Z w > Q - �zr w Q V Ja ..,--- U) Z J J 00 — O o l— MODULAR FABRICATOR AXONOMETRIC VIEW FROM SOUTHWEST AXONOMETRIC VIEW FROM SOUTHEAST APPROVALSTAMP i - THE COURTIER LU RESIDENCE 10490 WUNDERLICH DRIVE CUPERTINO CA 95014 I APN: 375-17-055 MASSING DIAGRAMS THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign scale 1/8"=1'-0" sheet AXONOMETRIC VIEW FROM NORTHEAST AXONOMETRIC VIEW FROM NORTHWEST A 0 . 5 1 BUILDING MASSING DIAGRAMS O TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap lication Number(s) ��SED ARC&/ Approval Body: Dir ctor/Staff �L ss e• LoNc Approval Date 1 /19/20 /11 Signature Ellen 4au C-28651 Case Manager 10.3A OF CAL1F0 ISSUE DATE FA PLANS V1 112019 45-21/2" FA DRAWINGS V1 121919 PLAN UPDATES 020720 50% DESIGN SET V1 022220 45'-03/4" L w 5Ae DESIGN SET 020 PLANNING SUBMITTAL V1 052952920 __ v � PLANNING SUBMITTAL REV1 080720 ____ � L PLANNING SUBMITTAL REV2 092420 O DECK MOD 1 N 0 ❑;r INSTALLED ON SITE' ARCHITECT 10'-3 7/8"' 10'-10 7/8" 24'-9 1/2" 0 rn J I U � X 25'-4" Y m MOD 2 co Q o " 'll DECKS o 0 z lJ GARAGE / N N L17 O INSTALLED /,DECK �( �� � ° � ( �* ON SITE/ INSTALL SITED FLOOR AREA CALCULATION Q w Q � KEY AREA (SQFT) w U J Q A 649.05 U) z Qo FIRST FLOOR C 229.97 Go D 371.87 ° FIRST FLOOR SUBTOTAL 1470.00 E 559.74 F 28.32 MODULAR FABRICATOR G 369.83 FIRST FLOOR SECOND FLOOR SUBTOTAL 958.89 TOTAL: 2,428.89 SQFT. 38'-11 7/8" FLOOR AREA MAXIMUM = 2,429.24 SQFT APPROVALSTAMP PROJECT COMPLIES E I i I I i I i 38'-10 3/8" � N ----- N MOD 3 THE COURTIER LU RESIDENCE 1/4 ROOF 34'-6 5/8" 10490 WUNDERLICH DRIVE CUPERTINO CA MOD 4 95014 /ROOF APN: 375-17-055 00 INSTALLED ON SITES /,ROOF INSTALLED ON SITE SECOND FLOOR MODULAR DIAGRAMS THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign scale 1/8"=V-0" 0 4 8 12 16 FT sheet SECOND FLOOR A 0 . 6 OC TOBYLONGDESIGN 2020 1 MODULAR DIAGRAMS 2 FLOOR AREA CALCULATIONS Community Development Department Planning Division — Cupertino 'CUPERTIN4 APPROVED Case # -2020-015 ApI-lication Number(s) - f EXISTING HOUSE -10490 WUNDERLICH DRIVE _ " � " S�D ARCH Approval Body: Director/Staff I I ti. , L�� S. wN . 1 t , I ^r V F�ys G Approva I Date 1 /19/20 Signature Ellen 4au arty, C-28651 CaseMarar'er �. .1 ° ;�I'41'i:t. d o F o _ - -��_ __ _— __ -=-- - I. L _ •� � �+i`� y _.-- _ _--"-�.,c��,�,�.- _ ISSUE DATE NWA _ r FA PLANS V1 112019 ,�' _ r ' ® ® ® m 1 • '' FA DRAWINGS V1 121919 PLAN UPDATES 020720 50% DESIGN SET V1 022220 ''s.. r 50% DESIGN SET V2 041420 ' + �r _;�--,�., i„ i���•y �anon ON � PLANNING SUBMITTAL V1 051820 -_�._i. - _fr. s 1 ,'✓:'�.f' y o.,�,.. _ � :t�,.r�.p.,_. } y, �, - �IIIIIIIII� �.� u ,+ _ ARCHITECT _ :- F 0 0 < [If U _j @� � I I O ° � �� o RL w J :�� ,� , - Q z Qo in EIELIE] I I 7 LLJJL1 I I I I I I I L U Lj MODULAR FABRICATOR 10490 WUNDERLICH DRIVE 18781 BARNHART AVENUE 18771 BARNHART AVENUE O o m IV IW IN u' aoI 0� ----30� `� APPROVAL STAMP v, QD I IN -----� OD v ow ---"1 I� m cl — ---1 a) o — 97.73 —� i IQ O N o hi -4 . o _ 48.8'2 Ln IN N 0 --_ 96 N w /.v — v �98 ro N I� o — -� N (WjA I t Z \ O INN \ w � so THE COURTIER LU RESIDENCE 4 w 10490 WUNDERLICH DRIVE OD 09 / 760 -SON �slel - y>s� p9.71 Io�°'s T 95014 INO CA �L6� 4 V �10y i A�� �Z S 95014 APN: 375-17-055 E. d I 'so M _ 0 o- 09'ZE -003 ICW lO �� I� 56�9 /B73o 710 ' ;° N STREET VIEW s,.o9 90 C— ODv Imo : I� WI °' I — Iw _ W w o .00) N'� � w 50.24 � � � ;�° I- .,, o I� � = ELEVATIONS rn cn0'S5 .I o I.40 100 z �I 51 cn Iv �1 0 cn --... ,'1 l��y N N ONi 5�16 I W `Ia p T V O THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR 0 - r c�0.31 N — _— w z N CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL 50-3 50.30 � O AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES `�30 I 50.30 5p 3 p 1 COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS v TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE D D N I PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN -p N N I N .p u, I ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ''ww I— m ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING co, vl t7 IN I— 0' I 14 O THEEXPRESS WRITTEN PERMISSION OF tobylongdesign cn o�--— —— 30' I I.p ," I� N I� � to I I� N�_, ,00 D I� N w scale 3¢93 49.67 I 49.66 I I"' N4 I*. �' 4s.s7 49.66 49.67 49.66 nl —�r� /ePa/ /877/ /B763 /8755 79.15 3/16"= 1'-0" 0/6747 /8739 /873i �— BARNHART ----- �, S- I L.L.A. 16622494 A V E• D Q I � Z O I 10 �I N _ sheet Go ELEVATION VIEW 1tt - ' A 0 . 7 2 STREET VIEW ELEVATIONS O TOBYLONGDESIGN 2020 I ommunity Develop ent Department Planning Divi 'on - Cupertino �05 'CUPERTIN PROVED GRAPHIC SCALE Case # -2020-015 I `� 6 8 0 4 8 16 32 Application Number(s) Cl- Appro I Body: Director/Staff I �. ° F � m Appro I Date 11/19/20 I � q-�p PPO' of ( IN FEET by 1 inch - 8 ft. 4-3-2017 Si gnat e Ellen Yau g Case Manager Rolled Conc. Curb Gutter 1� �� �� Rolled Conc. Curb Gutter aJv v ob I / / FD 3/4" IP WOOD/ TACK � IN CASTING W UN D ER L I CH D D. 5.00 I I O / // EI=50.00 (6 0' WIDE) FD 3/4" IP WOOD CTACK IN ASTING TILSON AVER S2 20 O7 - I I TC INLET BENCHMARK (ASSUMED) l 00 r1l �n00 RIM=So.ss I I I 00 NO°23 00 W _ SSMH-� / Vol �) I I - /- - -- -x ----- ------- ------ ------ _--- --- -- -_- . ° -- - - -------------- - - ---------- -------- -- - ------- --------- - ---- ---- I- -- / / r ---o-13 - - - - - - - - - - - - - ------------------------------a -- 1 4L o2» o SSFL EL=43.1 (calc) RIM-50.74 - - - - - - - - - - - - - - - - - - - - - - - - - SDMH� I - - - - O L=30. 47' R=20. 00' - - - - - - - - - - - - - - - - - - - - - - - - - - - EI=44.21 I D=87°16 '53" NO°23'00"W o NOTES 36"" FL I 86. 05 o ALL DISTANCES AND DIMENSIONS ARE IN FEET AND DECIMALS. I I I o UNDERGROUND UTILITY LOCATION IS BASED ON SURFACE EVIDENCE. cc c6 �� �� �� N BUILDING LOCATION DIMENSIONS ARE MEASURED PERPENDICULAR TO THE Rolled Conc. Curb Gutter �� �� �� �� Rolled Conc. Curb Gutter �� oPROPERTY LINES. h4v �(o I °. �Sfp/ om 6v : vm a� �m Conc. Sidewalk �m m DIMENSIONS TO THE BUILDING ARE TAKEN AT THE EXTERIOR FINISHED SURFACE. PP °'� 1.50.4 C°n Conc. Sidewalk so Dirt 0�' y Drivewa Driveway STUCCO SIDING IQ ���� � 50.5 x O 50. 6 x s �� O x x x x x O 49.6 x x 49.4 49.3 o° R9 Dirt °.� Dirt 6 TREE 10 50 6 Dirt 9� SSCo 486 49.2 Conc. FINISH FLOOR ELEVATION TAKEN AT DOOR THRESHOLD (EXTERIOR). s� 0 -50.5 9 BENCHMARK: ASSUMED DATUM, POINT AS SHOWN le TREE 0 �� I O 50. 5 i -49,4 6 6 TREE O Dirt Conc. 9 I I .0 C) �� o x Dirt °' `so x 49.7 Conc. ROCK A CURRENT TITLE REPORT FOR THE SUBJECT PROPERTY HAS NOT BEEN EXAMINED F� o so o LAWN �° 50.0 nl BY L. WADE HAMMOND LAND SURVEYOR. EASEMENTS OF RECORD MAY EXIST THAT �I ARE NOT SHOWN ON THIS MAP. BW Brick so s GA*T Brick x .49.7 5°� Sao Fence s so 8 Conc. l Conc. ° .50.6 Planter TREE SPECIES IDENTIFICATION: BEST EFFORT, WE ARE NOT ARBORISTS OR 50.7 N DENDROLOGISTS. 51-0 GgTF 50.4 50.1 9 x x g03 o EI=51.1 TREES SHOWN ARE 6" TRUNK DIAMETER OR LARGER, MEASURED 5' ABOVE GRADE I I I 7C 5 of X Dirf FINISH FLOOR EI=50.0 G r 1 I I 50.0 GARAGE SLAB FL 7 BW-50.2 I I I 50.1 WM 57.0 Brick p I U PlanterFL -50.2 I 49.6 LAWN s7. -50.6 she 50k Garage 50.2 I I x 51.0 03 T�' o 5D.7 5 Brick ° Dirt 5 i N87°39'53"W I I I ° Planter w RIDGE 50'7 Conc. ^a 50. 30' LEGEND w o�I 51.1 � ha soR �� .50.3 House w .5 �I 50.0 o FOUND POINT IN MONUMENT CASTING (AS NOTED) x 51.0 49 � I I g FL zl N87° g, 3„W 49.4 FL 51.1 Shed x 50.7 50.3x 499 O RECORD DATA / REFERENCE TC I 3 9-3 TC Brick Pil. Conc. Eln So `so I i i 49.8 TYP x o s 21 R So 4.8° x wM WA TER METER OR WATER VALVE BOX o - � Dirt I 50.2 I I nBrick 50.7 60.4 �° u Dirt t�5 50.5 Planter s 50.8 -,-RIDGE i o Dirt o x FIRE HYDRANT I m h c. Planter ° 51.0 50.9 Conc. Brick TREE - TRUNK DIAMETER IN INCHES v 16 12 8 OAK FL g So 50.6 Q TREE SPECIES IDENTIFICATION: BEST EFFORT, 49.3- BW L 49.7 499 LAWN x 50.6 x WE ARE NOT ARBORISTS OR DENDROLOGISTS 3 49.3 11 I I I I m Bay Windowr< I o Q) FL W II 50.7 OF o 20.9' 51.0 so o `o Brick Ret. x Wa O16 12 8 OAK TREE WITH MULTIPLE TRUNKS ° ^ S 9 0 ll Conc. Hedge 'M�Y� CN cOnC' s �^ g 1 s'c� os Dirt I 5 1 x TREE DRIP LINE POINTS TOWARDS TREE II o I I FL x (6 So9 Dirt oPP TRUNK f TRUNKS. TREE DRIP LINES ABOVE cn I I 49.3= Dirt Dirt coDirt '�� h�� Brick PROPERTY III I TG �� x Brick SD23'S7"Esc Planter x PROPERTY LOCATED AS SHOWN. g II'i50.0 i i 49.7 498 o Planter 105. 36 I TC 34 TOP OF CURB III -49.2 FL I I I I QD x x x FENCE lc I I N I I Q) of OVERHEAD WIRES L III' I I jljo I I OPP POWER POLE III I I FL I I I 49.2x� Building 12.34 SPOT ELEVATION II I I \ S8.14 SANITARY SEWER CLEAN OUT Q)•49.2 BW FL II 30.00' 49.7 SI GN 49.6 I I I I RIDGE TC II HANDICAP RAMP OR PARKING III I I TC ' RIDGE TC-8.97 JOHNSON AVE. II I I 49.5 II I I 4g;. ;-� STORM DRAIN CURB INLET INLET FL=12.34 II I I III I I II I I II II I I III I I III I I pO000000 0 °°000 LAND ABBRDVI A TIONS °°°1:7 00 \ ADC 0 L . wade Hammond I ° o NJADE °o o 4° �o° S tiq o BW BACK OF WALK °°°v o° o �'o o1�o CONC. CONCRETE o - PLS 6163 d o o Licensed Land S u r ve yo r TC TOP of CURB 10490 WUI�I DERLI CH DR. ono No . 6163 FL FLOW LINE o 0 o O O SDMH STORM DRAIN MANHOLE o * *°o° I �o ° ° 3 6660 Newark Blvd . Suite C P.U E PTiCRUTILITY E SEMENT I A PN: 3 75- 17-055 o�TgTF°°°°°°°°0 O°°°°° Newark California 94560 I L 0 T 1, TR 1088 00000F CALF °oo� � ooppOO ° Tel : (510) 579-6112 Fax: (510) 991 -8054 I LOT AREA: 5, 399 SQ. FT wade@whlandsurveyor. com Community Development Department Planning Division — Cupertino 'CUPERTIN4 APPROVED Case # -2020-015 ApI-lication Number(s) SE,1 ARC Y/ Approva I Body: Director/Staff V02O0 c,� oss E. L0/V14Approva I Date 1 /19/20 4- /11 Signature Ellen 4au C-28651 Case Manager ------------- - - ------ - x � RF ti1 P' Rolled Conc. Cu Gutter / OF CAL�F0 W U N R I C H DRIVE el ISSUE DATE GuC Gory' Conc. Sidewalk Conc. Sidewal FA PLANS V1 112019 FA DRAWINGS V1 121919 P / PLAN UPDATES 020720 PUS✓ 50%DESIGN SET V1 022220 50% DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 0 49.6 ® PLANNING SUBMITTAL REV2 092420 6 TREE �0 J � SSCO 00 O x x 50.5 ARCHITECT x .4 6 T EE 3'-0" FENCE v o U x x x 6'-0" FENCE � � Q o o co x 49.7 N U X �, O z U x �`'� � 50.0 x x w w ° ®x �9� W Q Q N J � _ LL ° I— QG 3'-0"FENCE CN o x`So �� J x GATE �01 50.8 x N x 49.7 � I cb � o //���/. Q- OL_ LU LID c5` z � GO��� x� h o x x � � a � �P• o a W Q FRONT YARD _ P� N 50.4 50.1 x x r- - - - - -r - - �O — — — — — — — — — — �— - -----�— - - -� x Qc� 3'-011 I /G� LINE OF WALL @ LEV 1 & LEV 2 I `ro Q o existing gas meter �P ' _J _J `4 I — o 06 I I 30'-0 5/8,, N _1 x LEV 1 &LEV 2 WALL LU i i @ @ II 61 c�0�` I 50.2 J _jI x MODULAR FABRICATOR W x I < � i ---f 5� 25'-0"SETBACK ENTRY PATH I LROO R O O ; I SECOND STORY I , z Z I Lu _ I Z J ------------- W 25'-0"SETBAC 20'-0"SETBACK I I ' I FIRST STORY K � I I , SEC ---- - 1 x SECOND STORY -� --- 50.3 LINE OF WALL @ LEV 1 ------- ' o a I l Q + I I 20'=0' SETBACK UPPER ROOF =j ' FIRST STORY ' 2'-0" I APPROVAL STAMP LU I TYP. I 50.3 z I I J ADJACENT LOIN Q }� I I w � I I I I s 0 i@ I LOWER ROOF x I J i ; I x Q j I So Z o I I I I LL l o I x DRIVEWAY o I z L I J ' o o_ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - x - i - - - - - �O• ' — — — — — — — — — — — — — i EELJ M — — — — — — 00 — — — — — — LEV. 1 OVERHANG I \ ( 0 VFR x 50.6 O LINE OF WALL @ LEV 1 I x Sp? Fq� ' LOWER ROOF 50.6 I m W //VFS z 20'-10 3/8" ' Q I O o \ 1 I o w o N ; I o U \ o THE COURTIER LU RESIDENCE LEV _ I > > �' 00 LO 10490 WUNDERLICH DRIVE II Ll I � � J I I o D \ x zr-o va° - CUPERTINO CA ----w-- -------_ ---- - - - - cr cso � 95014 DRIVEWAY DIM. I LINE OF WALL @ LEV 1 - - -- ---- --- - - - - J \ APN: 375-17-055 co O I °' - - - --- ---- ---- - - _» 'fix x o x o _ �- -- - - - - --� --- ll� x4j Q3--- -- lrj x m x x •6, S� U3 sp S A'� x 6'-0" FENCE ,� SITE PLAN 09 x FENCE G � h (o CO r\• h O• �� THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR v J CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT's SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES 7f r•'�r�i� x //► COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS x V L '5 7"E TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE C//� /S O L V PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN Cr Ln ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE P PROPERTY LINE 10536' 1 20' ANCHOR ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING N . PROJECT DATA THEEXPRESS WRITTEN PERMISSION OF tobylongdesign EA MENT PER— TR 1088 scale AREA CALCULATIONS NORTH ARROW ADJACENT LOT FIRST FLOOR 1,019 SQFT SECOND FLOOR 959 SQFT HOUSE SUBTOTAL 1,978 SQFT z 16 24 32 FT GARAGE 451 SQFT sheet TOTAL BUILDING AREA Z429 SQFT 1 . 2 (2,429.55 MAX) 1 SITE PLAN OC TO BYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap lication Number(s) ��SED ARC&/ Approval Body: Dir ctor/Staff vC• oss E. `oNc� �, Approval Date 1 /19/20 Copncrete Mow Band Wood Bench 11 Signature Ellen 4au -28651 Case Manager T E _ REFER TO LANDSCAPE PLANS OF THE HIGHLIGTED PLANTS, SHEET L2 & L3 FOR TF�OF 31 P JFoq:? C PRIVACY PLANTS AND DESCRIPTION a► / ISSUE DATE FA PLANS V1 112019 FA DRAWINGS V1 121919 / PLAN UPDATES 020720 / 50% DESIGN SET V1 022220 50% DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 �0 , ARCHITECT '00/ O Q Q � 2 QU @ J o 1-- (� � o \4— u7 M L W Ln z rn ❑ O��G Q 30 OOo p 00° 30.00. g0 00° 30.00� (✓`� W o Q V J - U) Z 0 0� r >00 �G (.0 1-- 0 El 0 0 1:1 �x o o MODULAR FABRICATOR 0 _0 ° ❑ ° ° ° ROOF 2ND LEVEL ° w _ ° ° 0 0 � M �j APPROVAL STAMP JL 30 p0� o 0 0 M O ARi _ � I I � DRIVEWAY BELOW ROOF GTF� ti ° I ° o I ° I ° I ° ° ° THE COURTIER LU RESIDENCE ROOF 10490 WUNDERLICH DRIVE CUPERTINO CA o ° 95014 ° o1 APN: 375-17-055 1( ——————————————————- -- ----------———————————————— PRIVACY PROTECTION PLAN THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL — — -- AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS B INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING 1000 IN, THEEXPRESS WRITTEN PERMISSION OF tobylongdesign scale Wood Vine Trellis 1/4"=1.4. Driveway with interlocking pavers 0 4 s 1z 16 FT 3' Concrete Walk Interlocking pavers sheet 6 Wood fence A 1 . 3 1 PRIVACY PROTECTION PLAN 3/16"= O TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap lication Number(s) SEI) ARC&/ Approval Body: Director/Staff NO°23'00"W / vL�`osse. L°NC' TFO� Approva I Date 1 /19/20 / 86.05' Signature Ellen 4au -28651 Case Manager Rolled Conc. Curb Gutter 10 3A �W U N D E RLIC H D RIVE OF CALIFOEL �CblCj���g( ISSUE DATE G / FA PLANS V1 112019 Gory' Conc. Sidewalk Conc. Sidewalk FA DRAWINGS V1 121919 P PLAN UPDATES 0220 50% DESIGN SET V1 02222220 50/° DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 SSC O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �. 77 ARCHITECT I 1 � O E F G H I aJ oX U U) QU 3- 4'-5 1/2" 8'-9" 18'-0 1/2" 2'-5 3/8" 7'-0 3/4" H 0 > Q O LU LL. O c Z PG 2 2 0 cv� A-3.0 cli m � o A4.0 0) * rn L LU Ur; J� o Q z C' Lu Q W-02 I I I 1 W-03 W-04 W-05 II W-06 i W-07 � Q V —————- ------------ ---- - ---- -------- -------- -------- -------- ------ 3-0 - �o I O Q o G 11'-10 3/4" 15'-1 3/8"1 ' ' ✓1 0 ' IN Q0 0 1 4 v 01/8" ~ " , I Im POWDER SHELVING I" - -------------------- O I - -----�- LIVING ' ' S'-10 i/s" DINING 1 I I I I I A 3.0 i STAIRS ING , A 3.0 I MODULAR FABRICATOR W I i • �� I COATS -- - - - - - - __ I -------- 25'-0"SETBACK i I I COVERED __ ENTRY PATH DECK __ _ ( �N ELECTRIC I SECOND STORY � I zo z ENTRY o METER 1 -03 I I I I I M M 20'-0"SETBACK \ O I I I I I I N I I I t W D-o5 I FIRST STORY 1 ------------------------------------- A4.0 w-11 , ' 20'-0"SETBACK/ ' I APPROVAL STAMP FIRST STORY i o MECH. 1 6-4 112" °r C) l F� of 4'-0" 8'-01, p , 1 , 1 w l 1 1uP I � I MUD/ I S ACKA ' LAUNDRY Ln D , o , 1 = 3 r REF 3 A-3.0 ' �' ' A-3.0 Z - II o COVERED DRIVEWAY ----�--- o DECK -------�--------- GARAGE--- 1 o-UP a KITCHEN I ly— LID OO � ------- ------ II - --- � -=--- -` - 1-------------'-�---- 1 ------- - --- -- -- -- ---- 17'-6------------- ----- ---- 1-- - -- - ,I-I --\-------- I --M-BBQ F CLO----------------------- - - - - - - - - - - - - - - -- - - - - - - PANTRY DWI F -- I------- - - ---------- ------ --------- ---- -- - RETRACTABLE BUG Ofl 6'-8 3/4" ' SCREENS AROUND I ' ` COVERED PORCH I m w NFS DECK I o o m THE COURTIER LU RESIDENCE I 21'-0 1/8' ') my 10490 WUNDERLICH DRIVE 20'-0" O DRIVEWAY DIM. ——— ——— — —— I n \ CUPERTINO CA O 1 — - ---T-- --- � - ti 95014 --= ———— — — — — — ———— 'r I APN 375 17 055 L_ � - - - - - -�--- 10 --- --- (D RETRACTABLE BUG � mi \ I � � UP I SCREENS AROUND PLANS PORCH PQ 2 2 A-3.0 I I 1 I I --� A4.1 I I 1 I 1 I 1 � THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL C AND DIGITAL SIGNATURE.TA EXPRESSLY RESERVES tr�tisyTrY>~:~T��~Ti T•�' L,J 2°2 3'5 7"E COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE I I I I I I I I I PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN {/'�1 ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE 105.36' 1'x20' ANCHOR PROJECT DATA ASSIGNEDTO WRIANYTTEN TENDERHIRD PERMISSION OFF bylong FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign NOTE: FRONT YARD EASEMENT PER TOTAL FRONT YARD SQ.FT- 1 ,265 SQ.FT TR 1088 scale TOTAL ALLOWED IMPERVIOUS AREA - 632.5 SQ.FT(50%) A B C D E F G H I AREA CALCULATIONS NORTH ARROW 1/4"=V-0" PROPOSED IMPERVIOUS AREA - 584 SQ.FT(46.2%) FIRST FLOOR 1,019 SQFT SECOND FLOOR 959 SQFT 0 4 8 12 16 FT HOUSE SUBTOTAL 1,978 SQFT z GARAGE 451 SQFT sheet TOTAL BUILDING AREA Z429 SQFT A 2 . 1 (2,429.55 MAX) 1 LEVEL 1 PLAN OC TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap lication Number(s) ��SED ARC&/TF Approval Body: Dir ctor/Staff \L ss e• LONc Approval Date 1 /19/20 /11 Signature Ellen 4au C-28651 Case Manager ���, �FN• 10.3A 11 \P � L�FOEL WUNDERLICH DRIVE OF CA ISSUE DATE FA PLANS V1 112019 FA DRAWINGS V1 121919 PLAN UPDATES 020720 50% DESIGN SET V1 022220 50% DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ----- I ARCHITECT 1 �; O E F G H I aJ U x U U) U QU 10'-3 7/8" 3- 4'-5 1/2" 6'-9" 18'-0 1/2" 2'-5 3/8" T-0 3/4" m 0 > Y O I (1) Q 00 O LU LL I O I /�I r2% U _ i QC 2 9 ~ LN CD A-3.0 m * o I !. o z L�Ci w I I GOB I I I I I I I I I Q , w QQ - �P W15 - ----W-16---- ---W-17-- ROOF ---W-18-- N --W19--- - -------- ------- V 2 W-14 I Q OJ SLOPE_,_ 3'-11 3/4" o I OPEN TO BELOW 1 I� I MASTER f 1 ----- - ---- BATH N -U) 1 ' ------ --<�-- `� '------- ------ - o----- - - ----------- ---------------- - -------- ---\\�� - -------- ----- - - --- -- - ---� -0 �� -L------A--------- ' SLOPE -J I 1 __ U (V '2-0" 1 1 IV 1 4'-4 7 , A-3.0 I W / 1 a WIC I MODULAR FABRICATOR ENTRY PATH - 25'-0"SETBACK E sLOPE MASTER I BELOW I , STUDY/DESK - ----- ROOF 13 BEDROOM I SECOND sTOR - a z DN ' 14'-21/2" HALL r N 1 M 211 SETBACK + I co � I I I W FIRST STORY __________ _ ___ C I I I I I I I I 5'-0„ --- I I W-23 SLOPE 2.0 ' I , I I 20'-0"SETBACK/' M N N 1 FIRST STORY 1 CLASS A RATED "' BEDROOM 3 MEMBRANE FLAT ROOF',-- BEDROOM 2 19 I I APPROVAL STAMP I (SLOPE AT 1/4" PER FT)� I 2'-0" ' 1 _ LINEN 9'-67/8" c0 SLOPE I , , 10'-0" _ I I ' I I I —H I - 2'-10" H , 3 3 I / - ROOF w_ IQ w -0— 0 ' A-3.0 I BATH Z ROOF DRIVEWAY I 4 SLOPE BELOW I 1 II LO ---------- ----IA- ---- ------'---------------------------- ----- ----------- -------- ----------- ----- ------------------------------II- LO O I 1 I - - - - - - } -- - - ---- O I ' W-28 - - - _ - - - W27- - - - - - - - - - - - - - - - - - - - - - - - - - W 'z6- 11- - - - -i- - - - - - - - - - - - - i ' 1 — — — — — 1 1 — — — — — — — — — I 'n I _ I_ - - - - - I - ih I_ -I- - - - - - - - - - - I I I I I I I 1 I - ' SLOPE ' I 1 -------------------------�- ASSARATED-- ----------------- ---'- ------------ Cfl 1 O ---------- ---fi ----- - ------------- - SLOPE MEMBRANE FLAT ROOF ' O I ROOF (SLOPE AT 1/4"PER FT) i I rn w 1 0 ,- 1 ' 1 I 0 o Zo m THE COURTIER LU RESIDENCE II I I I I I I I I I Cf) 10490 WUNDERLICH DRIVE I O CUPERTINO CA ♦ 1 I I -- -- --�-- 95014 1 o --_ - -- - --- ---- TI Ui o -------------1-- _ -- - - - =N- ------ ------------ ---- ------------------ ------- ------ -T- ---,--------------------------------- ------ o O I APN: 375-17-055 1. T - 1 -— ——— — ———— — � I U) I I I I I I I I I I I I I I I I I I O D I A 9 _J PLANS 2 —— __ _— — I I I I I I 2 I I I _ I I I I I I I A-3.0 I I I __ — —— —— — I — — — --I --- — -- -- — —� -- I I I I I I A4.1 -- � I I I I I _ THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES —— 1 __ —— —— COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS 8 INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE PROJECT DATA ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign A CB) C D E F G H Cl) scale AREA CALCULATIONS NORTH ARROW 1/4"=V-0" FIRST FLOOR 1,019 SQFT SECOND FLOOR 959 SQFT 0 4 8 12 16 FT HOUSE SUBTOTAL 1,978 SQFT z GARAGE 451 SQFT sheet TOTAL BUILDING AREA Z429 SQFT A ■ (2,429.55 MAX) 1 LEVEL 2 PLAN OC TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino CUPERTINO APPROVED Case# -2020-015 All Acation Number(s) ��SED ARCN7TF Approva I Body: Director/Staff \L ss E. 1-01,� �� Approva I Date 1 /19/20 v Q-° Signature Ellen lau C-28651 Case Manager Lek 10.3A �WUNDERLICH DRIVE OF CALIFO ISSUE DATE FA PLANS V1 112019 FA DRAWINGS V1 121919 PLAN UPDATES 020720 50%DESIGN SET V1 022220 50% DESIGN SET V2 041420 PLANNING SUBMITTAL V1 052920 PLANNING SUBMITTAL REV1 080720 PLANNING SUBMITTAL REV2 092420 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --� I ARCHITECT Q I i U W I O Q � m O Y } W _j I Q O G4- = I O H ��P 2 O I Lf) o 5� A4.0 m I Cl) rn Z) C) I I LO o���� I LO G o I Q ' wQ_ ��Q N LINE OF WALL BELOW I J Q I- - - - - - T- - �P — — — — — — — — — — — — — — — - ---r— - - - -I I QC� I J ° t I — o I 2'-0' cfl i I � I I SLOPE SLOPE TYP. i I I I i i II i I o i I I I i 2'-0" w m i I I ' I MODULAR FABRICATOR LLJ I O I --- I ' " I rENTRY PATH I LOWER 25-0 sEreacK BELOW ROOF J I SECOND STOR ----- 1 SLOPE UPPER SLOPE I z I ROOF I 20'-0"SETBACK W I I FIRST STORY ' MEMBRANE ROOF ----------------- CLASS A RATED I > SLOPE @ 1/4" PER FT. MIN. I I I ti-- ———— ——— SLOPE \\\ I I 0'-0"SETBACK ' I APPROVALSTAMP FIRST STORY - I I I I LOWER I ' ° I I Q I ROOF J SLOPE I I ' a E A 3.0 i o LOWER ' A-3.0 1 I Z SLOPE _)11 ROOF I ZI � i SLOPE I ' I DRIVEWAY I ' LINE OF WALL BELOW J - - - - - I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BELOW - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -i- - - - - - - - - - - - - - - I '' III I m III w I ' LOWER I o o I ROOF I o m THE COURTIER LU RESIDENCE I t t I � I � III 10490 WUNDER L ICH DRIVE ° D CUPERTINO CA - - - - - - - - - - - - - - - - - - - - - 95014 - - - - - - - - - - - - - — — — — — APN: 375-17-055 I — — — — — — - - - - - - m I Ili --I O 00 A n T� —— 68vation:0" PLANS I 2 — — —— —— —— meter:6" I — —— —— —— THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES —— —— —— —— —— COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS —— TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE PROJECT DATA ASSIGNEDTO ANYTHIRD WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION ION OF tobylongdesign scale AREA CALCULATIONS FIRST FLOOR 1,019 SQFT z°i SECOND FLOOR 959 SQFT 0 4 8 12 16 FT HOUSE SUBTOTAL1,978 SQFT GARAGE 451 SQFT sheet TOTAL BUILDING AREA Z429 SQFT (2,429.55 MAX) 3.273" 3.273" 20 1 ROOF PLAN OC TOBYLONGDESIGN 2020 Community Development Department Planning Division - Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 LEGEND Ap lication Number(s) � D A R Cy�T E` DUPLEX RECEPTACLE DATA PORT/WALL �L y`� Lp G l Approval Body: Director/StafF (� N �• Approva I Date 1 /19/20 Y TELEPHONE OUTLET V �O "I Signature Ellen 4aU II FOURPLEX RECEPTACLE D GARAGE DOOR DATA PAD C-28651 Case Manager WP WATERPROOF RECEPTACLE TV CABLE/TELEVISION RFN- 1❑ 3�:>1 Or C IL-0 O�- SWITCHED OUTLET SP SPEAKER LOCATION GROUND FAULT ISSUE DATE ( GFI CIRCUIT INTERRUPTER AV AV CONTROL PAD FA PLANS V1 112019 4III� FA DRAWINGS V1 121919 DEDICATED OUTLET PLAN UPDATES 020720 (�DED SINGLE POLE SWITCH 50% DESIGN SET V1 022220 ylli� 50% DESIGN SET V2 041420 D DIMMER SWITCH PLANNING SUBMITTAL V1 051820 ® FLOOR OUTLET 3 THREE WAY SWITCH CEILING OUTLET y Vs :Th VACANCY SENSOR EXHAUST FAN W/ Ds INTEGRATED FLUORESCENT LIGHT DOOR SWITCH AND HUMIDISTAT ARCHITECT zi WEATHER PROOF 0 O PENDANT O SURFACE MOUNTED rn U 100 W WP FIXTURE Q 0 Ux IIIIIIIIIII�a O SURFACE MOUNTED WEATHER PROOF U FIXTURE �P RECESSED DOWNLIGHT \U Q / Y m OR RECESSED LIGHT WEATHER PROOF QO 0 WALL MOUNTED LIGHT w (.0- � o \� ® RECESSED LIGHT-LED FIXTURE x (3) Ln CD zzlzo rn RECESSED DIRECTIONAL GDO GARAGE DOOR � rn GAS ® DOWNRIGHT(32W) OPENER W/LIGHT Q W METER STAINED WOOD EAVES Q MOTION ACTIVATED EXT. Q WALL MOUNTED Q W HR+ LLJ SCONCE W/FLOOD LIGHT W/PHOTCELL J Q O GFI O S SMOKE DETECTOR < Z �< FLUORESCENT TUBE Q Q Q (2)T5 UNITS @ 54W J J RL' \ RL _-- -- Z GAS LINE 0 co CARBON MONOXIDE DETECTOR c 0 R ®L L ®L O R L GD GARBAGE DISPOSAL T THERMOSTAT `VSDd D POWDER -\ DINING I • GFI TO LIGHT � I WP +HB HOSE BIB EXTERIOR DOWNLIGHT --ABOVE\ \ L COVERED I L MECHANICAL/ELECTRICAL/LIGHTING NOTES DECK COATS I STAIRS ELIVING R L iO 1 MODULAR FABRICATOR R L ELECTRIC 1.IN EVERY HABITABLE ROOM AN ELECTRICAL OUTLET SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE ON ANY METER WALL SPACE IS MORE THAN SIX FEET MEASURED HORIZONTALLY FROM ANY OUTLET IN THAT SPACE,INCLUDING ANY WALL JDS I o SPACE TWO FEET OR MORE IN WIDTH,THE WALL SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS,AND FIXED ROOM \ /�� / I o DIVIDERS AS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE(CEC)ARTICLE 210.52(A)(1)(2)&(3). S co /i-� 2.AT LEAST ONE WALL SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE ROOM,BATHROOM, ENTRY \ L �L HALLWAY,STAIRWAY,AND ATTACHED GARAGE OR DETACHED GARAGE WITH POWER AND AT OUTDOOR ENTRANCES/EXITS AS R � - (K) // =R=_--_-_-�R L Roo - --®L �R L REQUIRED BY CEC ARTICLE 210.70(A)(1)&(2). -� GFI /�� --- / `�-�---- 3D 3.ALL GENERAL-PURPOSE RECEPTACLES MOUNTED AT 12"FROM FLOOR UNLESS OTHERWISE NOTED. / Pt3�D 3D D 3D D 43D 3 3D \ \ 4.BRANCH CIRCUIT,FEEDER AND SERVICE CALCULATIONS SHALL BE PER CEC ARTICLE 220. 5.EACH MULTI-WIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL D - - - - - - - - - --\ - - - - - - - - - - - - - - - - - - - - - GFI \ R L R GFI UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES PER CEC ARTICLE 210.4(B)&(D). _ 1 L GFI --� GFI D I 6.IN ALL AREAS SPECIFIED IN 210.52 EVERY 125-VOLT,15 AND 20-AMP RECEPTACLE SHALL BE LISTED AS TAMPER-RESISTANT LWP \\ - - _ - -- - D \ �L /i �- ----- RECEPTACLES PER CEC ARTICLE 406.11. 7.ADDITIONAL CIRCUITS ARE REQUIRED FOR THE FURNACE,GARBAGE DISPOSAL,RANGE,OVEN AND DISHWASHER PER CEC APPROVAL STAMP ' R L_ ®L I/ ARTICLE 210.52. I \ GFI I I \ 8.SMALL APPLIANCE BRANCH CIRCUITS SHALL BE RATED AT 1500 VA EACH.PER CEC ARTICLE 220.52(A). GFI DrMUD/ / I \ R GFI �\ DIED • • GFI - 9.ALL 120-VOLT,15 AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS,DINING ROOMS, UNDRY L LIVING ROOMS,BEDROOMS,SUNROOMS,RECREATION ROOMS,CLOSETS,HALLWAYS,PARLORS,LIBRARIES OR OTHER SIMILAR L L cn ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER,COMBINATION TYPE DEVICE AS I REQUIRED BY CEC ARTICLE 210.12(B). \ Jor i R)LREF I 10.ALL RECEPTACLE OUTLETS SERVING COUNTERTOPS IN KITCHENS OF DWELLING UNITS TO BE GFCI PROTECTED PER CEC D I ARTICLE 210.8(A)(6). CI I / \ R COVERED R 11.A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL COUNTER SPACE 12 INCHES OR WIDER.RECEPTACLE OUTLET 1 I SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL IS MORE THAN 24 INCHES,MEASURED HORIZONTALLY FROM A 3D 3 3D / II DECK RECEPTACLE OUTLET IN THE SPACE PER CEC ARTICLE 210.52(C)(1). -_-------- - -- - - - - - GARAG EDO -----_--- - -may R �� KITCHEN I / (SCREENED) - - - - - - - 12.AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND COUNTER SPACE WITH A LONG DIMENSION OF 24 I L \ LG INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER AS REQUIRED BY CEC ARTICLE 210.52(C)(3). 3 L R L BB 13.COUNTER SPACES SEPARATED BY RANGE TOPS,REFRIGERATORS,OR SINKS SHALL BE CONSIDERED AS SEPARATE D COUNTER SPACES AND SHALL MEET THE REQUIREMENTS PER CEC ARTICLE 210.52(c)(1)(2)(3). GFI GFI DWIGFI3D 14.COUNTERTOP RECEPTACLE OUTLET LOCATIONS SHALL BE LOCATED NOT MORE THAN 20 INCHES ABOVE THE COUNTERTOP. O PANTRY D GD,0 0 a RECEPTACLE OUTLETS SHALL NOT BE INSTALLED IN A FACE UP POSITION IN WORK SURFACES OR COUNTERTOPS. RECEPTACLE O OUTLETS RENDERED NOT READILY ACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEDICATED 'GFI I I I WP SPACE SHALL NOT BE CONSIDERED AS THESE OUTLETS. THESE RECEPTACLES SHALL BE INSTALLED AS REQUIRED PER CEC ARTICLE 210.52(B)(5). I I I WIP WP 1 I I I - - -_GFI___ 15.AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN EACH BATHROOM WITHIN 3'-0"FROM BASIN.AT LEAST ONE GFI GFI COVERED 20-AMPRE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLETS.BATHROOM OUTLETS SHALL WP R DECK R R HAVE GFCI PROTECTION AS REQUIRED BY CEC ARTICLE 210.52(D)210.11 (C)(3)AND 210.8(A)(1). _ - �L O R �L J L - _ (SCREENEDD� - - 16.NO PART OF A HANGING FIXTURE IS ALLOWED CLOSER THAN 8 FEET ABOVE THE TUB RIM OR 3 FEET HORIZONTALLY FROM THE COURTIER LU RESIDENCE ---- THE TUB RIM PER ARTICLE 410.4(D),UNLESS LIGHT FIXTURES IN SHOWER ENCLOSURE ARE LABELED"SUITABLE FOR WET \ - - -- -- ----- - LOCATIONS".AT LEAST ONE OUTLET ON A SEPARATE 20-AMP CIRCUIT SHALL BE PROVIDED IN THE LAUNDRY AREA AND SHALL BE 10490 WU N DE RLICH DRIVE WITHIN SIX FEET OF THE INTENDED LOCATION OF THE APPLIANCE AS REQUIRED BY CEC ARTICLE 210.52(F)AND 210.11 (C)(2). p / ELECTRIC GFIT CUPERTINO CA PANEL 17.ALL 125 VOLT,SINGLE PHASE 15 AND 20-AMPERE RECEPTACLES INSTALLED WITHIN 6 FEET OF LAUNDRY,UTILITY OR WET BAR 95014 SHALL BE GROUND FAULT CIRCUIT INTERRUPTED AS REQUIRED BY CEC ARTICLE 210.8(A)(7). APN: 375-1 7-055 HB 18.VERIFY ALL APPLIANCE ELECTRICAL REQUIREMENTS WITH MANUFACTURER SPECS. 19.REFERENCE ARCHITECTURAL PLANS FOR ADDITIONAL INFO.20.ALIGN ALL LIGHTING SWITCH BOX LOCATIONS WITH RECEPTACLE OUTLET LOCATION BELOW WHERE POSSIBLE. PLANS /\ 21.ALL EXTERIOR LIGHTS SHALL BE CONTROLLED BY A MANUAL ON/OFF SWITCH,A MOTION SENSOR,AND A PHOTOCONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE PHOTOCONTROL,OR AN ASTRONOMICAL TIME CLOCK NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE ASTRONOMICAL TIME CLOCK. 22.MIN.220 AMP APPLIANCE CIRCUIT IS REQUIRED IN THE KITCHEN,DINNING,PANTRY. NOT TO BE USED FOR DIRECTLY WIRED THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR APPLIANCES AND NOT TO BE USED FOR ANY OTHER OUTLETS. CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS 23.ALL SMOKE AND SMOKE/CO ALARMS TO BE HARD WIRED AND INTERCONNECTED SO THAT IF ONE ALARM IS ACTIVATED,ALL TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE OTHER ALARMS WILL ACTIVATE. PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign scale 1/4"=1%0" sheet A 2 . 4 1 LEVEL 1 CEILING AND ELECTRICAL PLAN (C) TOBYLONGDESIGN 2020 Community Development Department Planning Division - Cupertino 'CUPERTIN4 APPROVED Case # -2020-015 LEGEND Ap lication Number(s) ti'S�D A R C ApprovaH�TF` Body: Director/Staff (� DUPLEX RECEPTACLE DATA PORT/WALL NL ys E LING Oj Approva I Date 1 /19/20 TELEPHONE OUTLET V FO Signature Ellen 4aU II FOURPLEX RECEPTACLE D GARAGE DOOR DATA PAD C-28651 Case Manager WP WATERPROOF RECEPTACLE TV CABLE/TELEVISION RFN. �0 31%ti° OF CpL1FO� SWITCHED OUTLET Fs PI SPEAKER LOCATION GROUND FAULT ISSUE DATE ( GFI CIRCUIT INTERRUPTER AV AV CONTROL PAD FA PLANS V1 112019 4III� FA DRAWINGS V1 121919 DEDICATED OUTLET PLAN UPDATES 020720 (�DED SINGLE POLE SWITCH 50% DESIGN SET V1 022220 ylli� 50% DESIGN SET V2 041420 D DIMMER SWITCH PLANNING SUBMITTAL V1 051820 ® FLOOR OUTLET 3 THREE WAY SWITCH CEILING OUTLET y VS ���✓ :TIC VACANCY SENSOR EXHAUST FAN W/ INTEGRATED FLUORESCENT LIGHT :ITS DOOR SWITCH AND HUMIDISTAT ARCHITECT WEATHER PROOF (.00 O PENDANT O SURFACE MOUNTED rn U 100 W WP FIXTURE maQ 0 N UH O SURFACE MOUNTED WEATHER PROOF > 0 2 FIXTURE �P RECESSED DOWNLIGHT O Q U > Y 00 OR RECESSED LIGHT WEATHER PROOF ( QO O WALL MOUNTED LIGHT � _ W® *04 RECESSED LIGHT-LED FIXTURE CD x (1) 0� � t1� o RECESSED DIRECTIONAL GDO GARAGE DOOR C Z) CD ® DOWNRIGHT(32W) OPENER W/LIGHT Cl LO W > WALL MOTION ACTIVATED EXT. Q STAINED WOOD EAVES SCONCE W/W/FLOOD LIGHT W/PHOTCELL J Q U JQ SMOKE DETECTOR U Z db �< FLUORESCENT TUBE O Q Q ARC ARC (2)T5 UNITS @ 54W J J _ MD ICARBON MONOXIDE r mOPEN TO BELOW - - - - GAS LINE DETECTOR U CO H R GD GARBAGE DISPOSAL O THERMOSTAT WP MASTER GFI -w_ R L R L --\ ----- - BATH -0- +HB HOSE BIB EXTERIOR DOWNLIGHT 1 W --- L --- ------ -v > \ Q �- ---------- ARC LLI MECHANICAL/ELECTRICAL/LIGHTING NOTES u�sD \ 00 MODULAR FABRICATOR ------_--- D W/C RL I o / L V D D I MASTER W 1.IN EVERY HABITABLE ROOM AN ELECTRICAL OUTLET SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE ON ANY STUDY/DESK GFI GFI D- Z WALL SPACE IS MORE THAN SIX FEET MEASURED HORIZONTALLY FROM ANY OUTLET IN THAT SPACE,INCLUDING ANY WALL BEDROOM Q SPACE TWO FEET OR MORE IN WIDTH,THE WALL SPACE OCCUPIED BY FIXED PANELS IN EXTERIOR WALLS,AND FIXED ROOM DIVIDERS AS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE(CEC)ARTICLE 210.52(A)(1)(2)&(3). 3 D\, - N - - _ _ �- VVD R L 2.AT LEAST ONE WALL SWITCH-CONTROLLED LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE ROOM,BATHROOM, HALLWAY,STAIRWAY,AND ATTACHED GARAGE OR DETACHED GARAGE WITH POWER AND AT OUTDOOR ENTRANCES/EXITS AS j S co - HALL R L i R L-�/ S co REQUIRED BY CEC ARTICLE 210.70(A)(1)&(2). ARC ARC ARC 3.ALL GENERAL-PURPOSE RECEPTACLES MOUNTED AT 12"FROM FLOOR UNLESS OTHERWISE NOTED. qp If JL i 4.BRANCH CIRCUIT,FEEDER AND SERVICE CALCULATIONS SHALL BE PER CEC ARTICLE 220. 111d5.EACH MULTI-WIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL db UNGROUNDED CONDUCTORS AT THE POINT WHERE THE BRANCH CIRCUIT ORIGINATES PER CEC ARTICLE 210.4(B)&(D). RC A C ARC ARC S CO S Co 6.RECEPTACLES PER CEC ARTICLE 406.IN ALL AREAS SPECIFIED IN 210.52 1 EERY 125-VOLT,15 AND 20-AMP RECEPTACLE SHALL BE LISTED AS TAMPER-RESISTANT 10) R R R L R L APPROVAL STAMP LU D D 7.ADDITIONAL CIRCUITS ARE REQUIRED FOR THE FURNACE,GARBAGE DISPOSAL,RANGE,OVEN AND DISHWASHER PER CEC > 4D ARTICLE 210.52. w BEDROOM 3 �\ 8.SMALL APPLIANCE BRANCH CIRCUITS SHALL BE RATED AT 1500 VA EACH.PER CEC ARTICLE 220.52(A). O ARC BEDROOM 2 CID D SD D LINEN _ J II ARC 9.ALL 120-VOLT,15 AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS,DINING ROOMS, LIVING ROOMS,BEDROOMS,SUNROOMS,RECREATION ROOMS,CLOSETS,HALLWAYS,PARLORS,LIBRARIES OR OTHER SIMILAR R L ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER,COMBINATION TYPE DEVICE AS W w- I REQUIRED BY CEC ARTICLE 210.12(B). Z W GFI \ U)- I Q 1 Q_ I 10.ALL RECEPTACLE OUTLETS SERVING COUNTERTOPS IN KITCHENS OF DWELLING UNITS TO BE GFCI PROTECTED PER CEC U) _ � BATH I R U -4 ARTICLE 210.8(A)(6). U WP R L R L 11.A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL COUNTER SPACE 12 INCHES OR WIDER.RECEPTACLE OUTLET R L �L SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL IS MORE THAN 24 INCHES,MEASURED HORIZONTALLY FROM A L-1 �� RECEPTACLE OUTLET IN THE SPACE PER CEC ARTICLE 210.52(C)(1). ARC ARC 12.AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH ISLAND COUNTER SPACE WITH A LONG DIMENSION OF 24 INCHES OR GREATER AND A SHORT DIMENSION OF 12 INCHES OR GREATER AS REQUIRED BY CEC ARTICLE 210.52(C)(3). 13.COUNTER SPACES SEPARATED BY RANGE TOPS,REFRIGERATORS,OR SINKS SHALL BE CONSIDERED AS SEPARATE 7 COUNTER SPACES AND SHALL MEET THE REQUIREMENTS PER CEC ARTICLE 210.52(c)(1)(2)(3). STAINED WOOD EAVES 14.COUNTERTOP RECEPTACLE OUTLET LOCATIONS SHALL BE LOCATED NOT MORE THAN 20 INCHES ABOVE THE COUNTERTOP. RECEPTACLE OUTLETS SHALL NOT BE INSTALLED IN A FACE UP POSITION IN WORK SURFACES OR COUNTERTOPS. RECEPTACLE OUTLETS RENDERED NOT READILY ACCESSIBLE BY APPLIANCES FASTENED IN PLACE OR APPLIANCES OCCUPYING DEDICATED SPACE SHALL NOT BE CONSIDERED AS THESE OUTLETS. THESE RECEPTACLES SHALL BE INSTALLED AS REQUIRED PER CEC ARTICLE 210.52(B)(5). 15.AT LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED IN EACH BATHROOM WITHIN T-0"FROM BASIN.AT LEAST ONE 20-AMPRE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLETS,BATHROOM OUTLETS SHALL HAVE GFCI PROTECTION AS REQUIRED BY CEC ARTICLE 210.52(D)210.11 (C)(3)AND 210.8(A)(1). 16.NO PART OF A HANGING FIXTURE IS ALLOWED CLOSER THAN 8 FEET ABOVE THE TUB RIM OR 3 FEET HORIZONTALLY FROM THE COURTIER LU RESIDENCE THE TUB RIM PER ARTICLE 410.4(D),UNLESS LIGHT FIXTURES IN SHOWER ENCLOSURE ARE LABELED"SUITABLE FOR WET 10490 WU N DERLICH DRIVE LOCATIONS".AT LEAST ONE OUTLET ON A SEPARATE 20-AMP CIRCUIT SHALL BE PROVIDED IN THE LAUNDRY AREA AND SHALL BE WITHIN SIX FEET OF THE INTENDED LOCATION OF THE APPLIANCE AS REQUIRED BY CEC ARTICLE 210.52(F)AND 210.11 (C)(2). CU PERTI NO CA 17.ALL 125 VOLT,SINGLE PHASE 15 AND 20-AMPERE RECEPTACLES INSTALLED WITHIN 6 FEET OF LAUNDRY,UTILITY OR WET BAR 95014 SHALL BE GROUND FAULT CIRCUIT INTERRUPTED AS REQUIRED BY CEC ARTICLE 210.8(A)(7). APN: 375-1 7-055 18.VERIFY ALL APPLIANCE ELECTRICAL REQUIREMENTS WITH MANUFACTURER SPECS. 19.REFERENCE ARCHITECTURAL PLANS FOR ADDITIONAL INFO.20.ALIGN ALL LIGHTING SWITCH BOX LOCATIONS WITH RECEPTACLE OUTLET LOCATION BELOW WHERE POSSIBLE. PLANS /\ 21.ALL EXTERIOR LIGHTS SHALL BE CONTROLLED BY MANUAL ON/OFF SWITCH,A MOTION SENSOR,AND A PHOTOCONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE PHOTOCONTROL,OR AN ASTRONOMICAL TIME CLOCK NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE ASTRONOMICAL TIME CLOCK. 22.MIN.220 AMP APPLIANCE CIRCUIT IS REQUIRED IN THE KITCHEN,DINNING,PANTRY. NOT TO BE USED FOR DIRECTLY WIRED THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR APPLIANCES AND NOT TO BE USED FOR ANY OTHER OUTLETS. CONSTRUCTION UNLESSTHEY BEAR THEARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES 23.ALL SMOKE AND SMOKE/CO ALARMS TO BE HARD WIRED AND INTERCONNECTED SO THAT IF ONE ALARM IS ACTIVATED,ALL COMMON LAWS&INFORMATIOHT ANDN IN THESE PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE OTHER ALARMS WILL ACTIVATE, PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign scale 1/4"=V-0" sheet A 2 . 5 1 LEVEL 2 PLANNG AND ELECTRICAL PLAN OC TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap Aication Number(s) '0 Approval Body: Director/Staff ARC Approva I Date 1 /19/20 % �° Signature Ellen tau C-28651 Case Manager sy� RFN 10 3A �` " OF CALXfO AL TOP OF ROOF TOP OF ROOF 22'-91/2" (74.43') 22'-91/2" (74.43') SECOND FLOOR PLATE SECOND FLOOR PLATE ISSUE DATE — — — — ------------ — 21'-51/2" (73.10-) 21'-5 1/2" (73.10') FA PLANS V1 112019 FA DRAWINGS V1 121919 PLAN UPDATES 020720 FF� \ 50% DESIGN SET V1 022220 MASTER MASTER MASTER Lo DESIGN SET V2 041420 ANNING SUBMITTAL V1 051820 BATH BEDROOM BEDROOM BEDROOM 3 P \ ARCHITECT SECOND FLOOR SECOND FLOOR 0 — — — — ----- ---------- --------------- — — — — U 12'-11 1/2"(64.10') M M 12'-11 Q FIRST FLOOR PLATE M � FIRST FLOOR PLATE U ————— ———— tfl N —————— — X 11'-61/4" 62.62') 11'-6 1/4" 62.62') 0 = 14 � ZU Q M Y } STAIR Q o O � ENTRY COATS �,� / DINING LIVING \ COVERED `� qt o COVERED I o o x LIVING KITCHEN DECK o w o DECK (SCREENED) z C; L > � 0 w Q VJ FIRST FLOOR FIRST FLOOR J J —————————— 1'-6 1/4"(52.62') ? ? 1'-6 1/4"(52.62') GRAD GRADE cfl 0'-0-' (— ) LOW DECK Z Z BELOW DECK 0'-0-- CRAWLSPACE00 CRAWLSPACE MODULAR FABRICATOR 0 4 8 12 16 FT 0 4 8 12 16 FT 1 BUILDING CROSS SECTION 3/16"=1'-0" 2 BUILDING CROSS SECTION 3/16"=1'-0" w Y w Z U U U Z J Q Q m Y J � m m w Q APPROVAL STAMP w U U) w N o uJ O J9 J � IjiO CA O wo w [n > N d >LIJN > LLl J OLU 0_ JUI JVI JAI who`` LU V I I I I TOP OF ROOF TOP OF ROOF 22'-91/2" (74.43') 22'-91/2" (74.43') SECOND FLOOR PLATE ———————————————— SECOND FLOOR PLATE — — — — —————————————————————————————————————— —————— — — — 21'-51/2" (73.10') 21'-51/2" (73.10') I I I I i BEDROOM 2 BATH BEDROOM 3 I I I I SECOND FLOOR SECOND FLOOR THE COURTIER LU RESIDENCE 12'-111/2"(64.10')— — — ————————————— ---------------------------- ? — — —12'-11 1/2"(64.10') 10490 WUNDERLICH DRIVE Cl) FIRST FLOOR PLATE `? `� FIRST FLOOR PLATE CUPERTINO CA 11'-61/4" 62.62') 11'61/4" 62.62') 95014 APN: 375-17-055 GARAGE MUD/ KITCHEN / COVERED.' ` SECTIONS LAUNDRY o 0 (SCREENED) \ THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING THEEXPRESS WRITTEN PERMISSION OF tobylongdesign FIRST FLOOR _ FIRST FLOOR 1'-61/4"(52.62') --- --—---- - �_ 1'-61/4"(52.62') scale GRADE `D GRADE BELOW DECK 0'-0" (—._') AS NOTED CRAWLSPACE 0 4 8 12 16 FT sheet A 3 . 0 00, 3 BUILDING CROSS SECTION O TOBYLONGDESIGN 2020 Community Development Department Planning Division — Cupertino 'CUPLRTIN4 APPROVED Case # -2020-015 Ap Acation Number(s) �SVp ARC/y7T Approva I Body: Director/Staff LU Y Y Z \C ,, ,- ss e• LO,� Fc�� Approva I Date 1 /19/20 m m m Q-o Signature Ellen lau w w LU - w� w w l � w C-28651 Case Manager 0- N cN p CL O 06 I jch Jp O > ��` > IL WO JV W � �eN• 10.31;1"1 \P w T� TF OF CAL\FOEi J V TOP OF ROOF TOP OF ROOF OL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22'-91/2" (74.43') � — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T - - - - - - - - - � 22'-91/2" (74.43') ISSUE DATE SECOND FLOOR PLATE 1— SECOND FLOOR PLATE — — — ----------- FA PLANS V1 112019 21'-5 1/2" (73.10-) _ 21'-5 1/2" (73.10') FA DRAWINGS V1 121919 PLAN UPDATES 020720 STAINED CEDAR INOPERABLE INOPERABLE - ------ 50%DESIGN SET V1 022220 EAVES -_ /)'' 50% DESIGN SET V2 041420 PAINTED METAL TRIM PLANNING SUBMITTAL V1 052920 PAINTED METAL TRIM TO MATCH WINDOW COLOR PLANNING SUBMITTAL REV1 080720 TO MATCH WINDOW PLANNING SUBMITTAL REV2 092420 COLOR m FIBERGLASS o WINDOWS J O ~ e�i STAINED/PAINTED E-v o CO �`NG`��F WOOD SIDING ARCHITECT SECOND FLOOR WOOD PRIVACY ��\�i C� 12 .00 N E- � \OOF SECOND FLOOR OU LL- - - — -------+ --- ---------------- — OL 12'-11 1/2' (64.10') M >———————— M 12'-11 1/2"(64.10') Q Q� U H FIRST FLOOR PLATE ——C 1 00 FIRST FLOOR PLATE X N 11'-6 1/4" 62.62') ' o oo 11'-6 1/4" 62.62') O Q U N > Y m + OH it� � CD w a - - - - - SMOOTH INTEGRAL q Z) o I w - rn O Q 0 + 0 w a COLOR STUCCO Lu Ln LU I >11 o (GRAY) j W Z . Q z . o z cwI w 9� Q 0 I I Z J Q I 7 0� QO m _ U Z m J OJ FIRST FLOOR FIRST FLOOR I — — — ----------- --T----------------- 103 — v 1'-6 1/4"(52.62') - OQ GRADE 19 GRADE OIL J NATURAL NATURAL NATURAL GRADE-50.7' GRADE-50.8' GRADE-50.8' MODULAR FABRICATOR 0 4 8 12 16 FT 1 SOUTH ELEVATION (FRONT) w LLI Z U U U Z J Y m Q Q ca Q w w w w l N o LU N - ww APPROVAL STAMP O cn wLO Jai O Q > N > N O > > N Uj J � Iwo J � J V LU TOP OF ROOF TOP OF ROOF 22'-9 1/2" (74.43') - - - - - - - - - - - - - - - - - - - - - - - - -�- - - - - - - - - - - - - - - - - - -_ - - - - 22'-9 1/2" (74.43') v SECOND FLOOR PLATE I - - + SECOND FLOOR PLATE 21'-51/2" (73.10') STAINED CEDAR EAVES INOPERABLE INOPERABLE INOPERABLE INOPERABLE INOPERABLF4 < PAINTED METAL PAINTED METAL TRIM _ TRIM AND FASCIA TO MATCH WINDOW _------ 1 �I w COLOR �- PAINTED METAL WINDOW COLOR q WOOD PRIVACY -- TRIM TO MATCH ° SCREENS J r Luu 1 LI I 0 I J .° I Lou FIBERGLASS STAINED/PAINTED -- J LLL IJ J WINDOWS WOOD SIDING --- --------- o Jco r- _ O o O LL U) o O LL 4 o M F- WOOD PRIVACY SECOND FLOOR li LL LL LE SCREENS SECOND FLOOR M _ M 12'-111/2"(64.10') THE COURTIER LU RESIDENCE 10490 WUNDERLICH DRIVE LL 12'-11 1/2"(64.10') v FIRST FLOOR PLATE U? FIRST FLOOR PLATE ao --- a 11'-61/4" 62.62') — —-- — — 11'-61/4" 62.62') a CUPERTINO CA 6. 95014 APN: 375-17-055 SMOOTH INTEGRAL # COLOR STUCCO (GRAY) x } ELEVATIONS o - ACCENT PANELS " - - THESE PLANS ARE CONSIDERED PRELIMINARY AND NOT FOR _ I CONSTRUCTION UNLESS THEY BEAR THE ARCHITECT'S SEAL AND DIGITAL SIGNATURE.TLD EXPRESSLY RESERVES COMMON LAW COPYRIGHT AND OTHER PROPRIETARY RIGHTS TO ALL DESIGNS&INFORMATION IN THESE PLANS.THESE PLANS ARE NOT TO BE REPRODUCED,CHANGED OR COPIED IN - ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY,WITHOUT FIRST OBTAINING FIRST FLOOR FIRST FLOOR THEEXPRESS WRITTEN PERMISSION OF tobylongdesign II I i\ v 1'-61/4" 52.62' OL GRADE31 GRADE scale NATURAL (E)GRADE-50.3' NATURA NATURAL (E)GRADE-50.8' (E)GRADE-50.7' 8 12 16 FT sheet A 4 . 0 2 WEST ELEVATION OC TOBYLONGDESIGN 2020