B-2019-0242 Soils ReportCAPER ENGINEERING INC.
P.O. BOX 14198, FREMONT, CA 94539
Tel: (408) 609-1115
E-mail: capexinc888@gmail.com
GEOTECHNICAL INVESTIGATION REPORT
PROPOSED TWO-STORY NEW RESIDENCE
AT
21164 LAURETTA DR.
CUPERTINO, CA
CAPEX ENGINEERING INC.
Project No. 11241
December 22, 2018
[dl]:2=l:i9lki[6]
Building Department
REVIEWED FOR CODE COMPLIANCE
Reviewed By: Phuong Devries
Date: 04/01/19
CAPER ENGINEERING INC.
P.O.BOX 14198, FREMONT, CA 94539
Tel :(408) 609-1 115
E-mail: capexinc888@gmail.com
Eric Yeh/Luz Serrano
21164 Lauretta Dr.
Cupertino, CA
Project No. 11241
December 22, 2018
Subject: Proposed Two-story New Residence at
21164 Lauretta Dr.
Cupertino, CA
GEOTECHNICAL INVESTIGATION AND FOUNDATION
RECOMMENDATION REPORT
Dear Eric Yeh/Luz Serrano:
In accordance with your authorization, CAPER ENGINEERING INC. has completed a
geotechnical investigation at the subject site. Recommendations are based on our site
investigation, laboratory test result analysis and proposed site plan.
The accompanying report presents the results of our geotechnical investigation. Our
findings indicate that the site is suitable, from a geotechnical standpoint, for the proposed
two-story new residence provided the recommendations of this report are carefully
followed and are incorporated into the project plans and specifications.
We appreciate the opportunity to be of service to you. Should you have any questions
relating to the contents of this report or should you require additional information, please
do not hesitate to contact our office at your convenience.
Very truly yours,
CAPEX ENGINEERING INC.
�a y A,—E----
-
Principal
U
QRpFESSlczi
Q��q
it N o . CZ yo
4L Exp.
P
OF CAt P
CAPER ENGINEERING INC. 2
TABLE OF CONTENTS
Pam
LETTER OF TRANSMITAL
2
1.0
Introduction
4
2.0
Site location & Description
4
3.0
Field Investigation
4
4.0
Soil Conditions
4
5.0
Laboratory Testing
5
6.0
C.B.0 Earthquake Design Criteria
5
7.0
Liquefaction Potential and liquefaction -induced lateral spreading
Evaluation
5
8.0
Discussion, Conclusions & Recommendations
6
8.1 General
6
8.2 Grading & Compaction
6
8.3 Foundations
7
8.4 Concrete Slab on Grade
7
8.5 General Construction Requirement
8
9.0
Construction Observation
9
10.0
Limitations and Uniformity of Conditions
9
Figures:
1. Site Location Map
11
2. Site Plan
12
3. Log of Test Boring
13
CAPEX ENGINEERING INC. 3
1.0 INTRODUCTION
The purpose of the geotechnical investigation for the proposed two-story new
residence, development located at 21164 Lauretta Dr., Cupertino, California was
to determine the surface and subsurface soil conditions at the subject site. Based
on the data and information obtained, we have provided recommendations for
foundation design and grading criteria for the site.
The scope of our work included the following:
1. Site reconnaissance by Project Engineer.
2. Subsurface exploration consisted of boring exploration at 15 feet
3. Performed laboratory tests to provide engineering criteria.
4. The preparation and writing of this report which presents our findings,
conclusions and recommendations.
Our findings indicate that the proposed development is feasible from a
geotechnical standpoint provided the recommendations in this report are included
into the project plans and specifications and adhered to during and after
construction.
2.0 SITE LOCATIONS AND DESCRIPTION
The site is located on 21164 Lauretta Dr., Cupertino, CA. The proposed project is
understood to consist of construction one-story new residence. The site is flat and
the surrounding lots of the site are developed with residence. The above
description is based on site reconnaissance by the project engineer and a site plan.
3.0 FIELD INVESTIGATION
The field investigation was performed on December 12, 2018 and included a site
reconnaissance by the project engineer and an excavation of one 15 feet deep
boring at the proposed project area.
4.0 SOIL CONDITIONS
The soil conditions were derived from our site reconnaissance and the information
and samples obtained from our exploratory boring. Detailed descriptions of the
materials encountered in the laboratory borings and the results of the laboratory
tests are presented on "Log of Test Boring" (Figure 3).
The subsurface soils condition was found to consist of brown silty clay to the
maximum depth excavation of 15 feet. No rock strata encountered with depth of
exploration at least 10 feet.
CAPEX ENGINEERING INC. 4
No ground water was encountered during boring excavation operations. However,
fluctuations in the groundwater table are anticipated with seasonal rainfall
variations. The boring was backfilled on the date of excavation.
5.0 LABORATORY TESTINGS
5.1 All samples were visually classified in the laboratory in accordance with
the Unified Soil Classification System per ASTM D-2487 and/or D-2488
in order to verify the field classification.
5.2 The natural moisture contents and dry unit weights were determined for all
undisturbed samples per ASTM D-2216.
5.3 Gradation tests were performed on selective samples per ASTM D-442 in
order to provide engineering characteristics of the material and for
liquefaction potential evaluation.
5.4 Atterberg Limits were performed per ASTM D-D427 for swell/shrink
potential evaluation
The results of Atterberg Limits test indicate that the near surface soils exhibit a
medium percentage of fines and are subject to a medium swell/shrink potential
with variation in moisture content. (P.I = 14.5)
6.0 C.B.0 (2016 EDITION) EARTHQUAKE DESIGN CRITERIA
The seismic design parameters for the site per Chapter 16 of the California
Building Code (2016 Edition) are follows:
Latitude: 37.327201 (degree); Longitude:-122.044571 (degree)
Site Class = D
Short Term Spectral Response Parameter Ss=1.89 g
Design Short Term Spectral Response Parameter SDs=1.26 g
1 Second Spectral Response Parameter S 1=0.716 g
1 Second Design Spectral Response Parameter SDi=0.716 g
7.0 LIQUEFACTION POTENTIAL AND LIQUEFACTION -INDUCED
LATERAL SPREADING EVALUATION
Liquefaction occurs primarily in relatively loose, saturated, cohesionless soils
which can be subjected to a temporary loss of strength due to the buildup pore
pressures, especially as a result of cyclic loading such as induced by earthquakes.
Evaluation of liquefaction potential on this site was based on the soil type, density
of the site soils, and the presence of groundwater. Based on the data obtained
during our field and laboratory investigations, it is our opinion that the
liquefaction potential at this site is nil.
CAPEX ENGINEERING INC.
8.0 DISCUSSION, CONCLUSIONS AND RECOMMENDATIONS
8.1 General
From a geotechnical standpoint, for the proposed addition development is
feasible for construction on the subject site provided the recommendations
presented in this report are carefully followed and are incorporated into
the project plans and specifications.
8.2 Grading & Compaction
8.2.1 Prior to any grading, demolition of the site should be completed.
This should include the removal of the existing residential
structure and any concrete foundations, underground utilities or
any other surface or sub -surface structure which may be
encountered. Any tree root system, debris or trashes that are
encountered should also be removed. It is vital that CAPEX
ENGINEERING INC. observe the demolition operation and be
notified in ample time to ensure that no sub -surface structures are
covered and that any tree root system completely removed.
8.2.1 All on -site material having an organic content of less than 1% by
volume and free from other deleterious materials are suitable for
use as fill on site. All fill material should have a maximum particle
size of 6 inches with no more than 15% larger than 2.5 inches.
8.2.2 Any import fills which is predominately granular in nature and
with plasticity index of 12 or less can be used. The soil engineer
should give final approval of any import fill material prior to
placement. The contractor shall notify the soil engineer 5 working
days in advance of his intention to import soil from any other
source outside the site area and shall permit the engineer to sample
as necessary for the purpose of performing tests to establish the
qualities of the material.
8.2.3 After preparation of the native ground soils, the site may be
brought to the desired finish grade by placing on -site native
material or import material in lifts not to exceed 8 inches in
uncompacted thickness. Compacted to a minimum of 90% as
determined by ASTM D-1557-91 laboratory testing procedure.
8.2.4 The moisture content of the fill material should be 0 to 3% above
optimum and sufficient to obtain the required density. Water
should be added or other satisfactory method shall aerate the fill
material in order to have acceptable range for moisture.
CAPEX ENGINEERING INC. 6
8.3 Foundations
8.3.1 The proposed structure can be satisfactory supported on spread and
continuous (grade beams) footings foundation system provided the
site is prepared as previously recommended.
8.3.2 The following soil design parameters apply:
a. Allowable soil bearing pressure (DL + LL )------1,500 psf
b. Allowable soil bearing pressure (All Loads) ------ 2,000 psf
C. Lateral passive pressure ------------------------------- 150 pcf
d. Coefficient of sliding ----------------------------------- 0.25
8.3.3 Extend all footings at least 24 inches below the undisturbed ground
surface. Foundation widths should conform to CBC minimum
standards provided the soil bearing stress recommendations of this
report are not exceeded. Footings should be reinforced using a
minimum of one # 4 bar at the top and the bottom. The footings
should be reinforced as determined by the Structural Engineer
based upon the building loads.
8.3.4 Total settlement of the subsoil beneath foundation depth at normal
loading is expected to be on the order of 1.0 inch and differential
settlement of 0.5 inch.
8.4 CONCRETE SLAB ON GRADE
8.4.1 Concrete slab should be structurally reinforced using at least No. 4
bars, within the middle of slab, at 18 inches on centers both ways.
The structural engineer may determine that additional
reinforcement is required based on the intended use and loading of
the slab.
8.4.2 Slab on grade should be underlain by a minimum of 6 inches of
granular material conforming to Caltrains Specifications for Class
II permeable material in order to provide a capillary moisture
break. An impervious membrane of 10 mils minimum thickness
should be placed over the granular material in order to provide
vapor barrier.
8.4.3 All flatwork slabs should be poured structurally independent of the
foundations. A 30-pound felt strip, expansive joint material, or
other positive separator should be provided around the edge of all
floating slabs to prevent bond to the structure foundation.
CAPEX ENGINEERING INC. 7
8.5 GENERAL CONSTRUCTION REQUIREMENTS
Surface Drainage and Irrigation:
8.5.1 All finish grades should provide a positive gradient to an adequate
discharge point in order to provide rapid removal of surface water runoff
away from all foundations. No stilling water should be allowed on the pad
or adjacent to the foundations. These lot slopes should be provided to aid
in the removal of water from the pads and to reduce the amount of water
to seep beneath the buildings. Surface drainage should be provided as
designed by the project engineer and maintained by the property owner at
all times afterwards.
8.5.2 All finish grade drainage swales must be cut into compacted finish grade.
Construction of the drainage swales using uncompacted loose surface fill
does not meet the recommended grading requirement.
8.5.3 Continuous roof gutters are recommended. Water from the
gutter/downspout shall be discharged away from the foundation, thus
reduce the possibility of soil saturation adjacent to the foundations and
engineered fill.
8.5.4 Planters should be avoided adjacent to the foundation. Should planters be
constructed, foliage requiring little irrigation should be considered to
further reduce the amount of water that could affect the foundation.
Alternatively, a watertight planter box with controlled discharge should be
provided.
Utility Trenches:
8.5.5 Any utility trenches extending under the building areas should be
backfilled with native on -site soils or approved import materials. Backfill
should be properly compacted to prevent water migration through the
utility trenches extending underneath the structure.
8.5.6 Utility trenches extending underneath all traffic areas must be backfilled
with native or approved import material and compacted to a relative
compaction of 90% to within 12 inches of the subgrade. The upper 12
inches should be compacted to 95% relative compaction. Backfilling and
compaction of these trenches must meet the requirement set forth by the
City of Cupertino, Department of Public Works.
8.5.7 The soils generated from trenching may be used as backfill with the
exception of cobbles greater than 6 inches in largest dimension.
Compaction of the trench backfill should comply with the requirements set
forth by the City of Cupertino, Department of Public Works.
CAPEX ENGINEERING INC. 8
Trench Shoring and Temporary Slopes
8.5.8 Applicable safety standards require that trenches in excess of 5 feet must
be properly shored or that the walls of the trench slope back to provide
safety for installation of lines. If trench wall sloping is performed, the
inclination should vary with the soil type. The underground contractor
should request an opinion from the soil engineer as to the type of soil and
the resulting inclination. Slope of 1:1 (horizontal to vertical) may be
utilized for stable cohesive soils while 2:1 will be required for the more
granular loose soil.
9.0 CONSTRUCTION OBSERVATION
The recommendations of this report are based upon assumptions regarding design
concepts, and construction materials and procedures. To validate these
recommendations, Capex Engineering Inc. must be retained to:
a. Review the drainage and foundation plans.
b. Review the structural calculations related to the foundations.
C. Observe the preparation of the site for slab -on grade construction.
d. Observe the foundation excavations to determine if the exposed
soil conditions are substantially the same as those encountered in
this report; and, to make alternative recommendations based upon
professional judgment.
e. Observe the initial and final site grading and installation of surface
and subsurface drainage.
10.0 LIMITATIONS AND UNIFORMITY OF CONDITIONS
10.1 The recommendations of this report are based on the assumption that the
soil conditions do not deviate from those disclosed and from a
reconnaissance of the site. Should any variations or undesirable conditions
be encountered during the construction, Capex Engineering Inc. will
provide supplemental recommendations as dictated by the field conditions.
10.2 This report is issued with the understanding that it is the responsibility for
owner or his representative, to ensure that the information and
recommendations contained herein are brought to the attention of the
Architect, Engineer and Contractor for the project and incorporated into
the plans and that the necessary steps are taken to see that the contractor
and subcontractor carry out such recommendations in the field.
CAPEX ENGINEERING INC. 9
10.3 This report specifically recommends that Capex Engineering Inc. be
retained to review the project plans and to provide observations and/or
testing services during construction. It is the responsibility of the client to
retain Capex Engineering Inc. and to inform Capex Engineering Inc. of the
need for such services.
10.4 The conclusions and recommendations contained in this report will not be
considered valid after a period of two (2) years, unless the changes are
reviewed and conclusions of this report modified or verified in writing.
10.5 Capex Engineering Inc. does not provide design services, nor does Capex
Engineering Inc. act as a builder. Our professional findings and
recommendations were prepared in accordance with generally accepted
engineering principals and practices. NO other warranty, expressed or
implied, is made.
CAPEX ENGINEERING INC. 10
LOCATION MAP
Hazelbrook Or
Rum`oro Dr
�21164 Lauretta Drive
10 min drive - home
F arKWood Or
Chr
a
Glen PI Cupertino R rCe eat
y�I & Community Servil
Go gle
4 ' Alvnc n.
Figure 1
Project No. 11241 December 22, 2018
CAPER ENGINEERING INC. 21164 L.auretta Dr.
Cupertino, CA
SITE PLAN
Approximate Location of Test Borings
Project No. 11241
CAPEX ENGINEERING INC
Figure 2
December 22, 2018
21164 Lauretta Dr.
Cupertino, CA
21164 Lauretta Dr., Cupertino
Project No. 11241 22 December 2018
LL
O
Z
C
•- O
0 :r
�
p J
p
N
N
Description
u
d
EL
Remarks
s
CLE
S N
_
30
�Ci
r-
o
m
c m
o�d`b'F
N�
U)
1
Light brown Silty Clay
2
3
Light Brown Silty Clay with gravel, moist , very stiff
1-1
CL
22
114.5
14-0
2.0
Unconfined Compressive
4
Uc =2,350 psf
5
Atterberg Limits Test
PI=14.5
6
Same As Above
7
8
9
Light Brown Silty Clay with gravel, moist, stiff
1-2
CL
24
115.0
14.5
2.5
10
11
12
Same As Above
13
14
15
Light brown Silty Clay with gravel, moist, stiff
1-3
CL
65
115.5
15.0
2.5
Terminated of Boring at depth of 15 feet,
16
groundwater was not encountered
during boring
17
18
19
20
21
22
23
24
25
BORING LOG NO. 1
Figure No. 3
CAPEX ENGINEERING INC.
- - - ---
-- - -
Date Drilled. 12/17/2018 By: G.H
Project No. 11241