Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD-2021-1082 Specs
Arnold Hom 06/16/21 El i LR6-60H PB 300~320M Cell Orientation:120 (6x20) Units: ..(inch) Junction Box: IP67, three diodes Tolerance: Length:±2mm Output Cable: 4mm2, 300mm in length Width: ±2mm length can be customized Height ±1mm Ptth- ±lmm Glass: Single glass 3.2mmCoated tempered glass Operational Temperature: -40 C - +85 C Power Output Tolerance: 0 - +5 W Voc and Isc Tolerance: ±3% Maximum System Voltage: DC1000V (IEC/UL) Maximum Series Fuse Rating: 20A Nominal Operating Cell Temperature: 45±2 C Safety Class: Class II Fire Rating: ULtype 1 ortype 2 Model Number LR6-60HPB-300M LR6-60HPB-305M LR6-60HPB-310M LR6-60HPB-315M LR6-60HPB-320M Testing Condition STC NOCT STC NOCT STC NOCT STC NOCT STC NOCT Maximum Power (Pmax/W) 300 222.2 305 225.9 310 229.6 315 233.4 320 237.1 Open Circuit Voltage (Voc/V) 39.8 37.1 40.1 37.4 40.3 37.7 40.6 37.9 40.9 38.2 Short Circuit Current (Isc/A) 9.70 7.82 9.78 j 7.88 9.86 7.94 9.94 8.01 10.02 8.08 Voltage at Maximum Power (Vmp/V) 32.9 30.4 33.1 j 30.6 33.3 30.8 33.7 31.1 33.9 31.3 Current at Maximum Power (Imp/A) 9.13 7.32 9.21 7.38 9.30 7.46 9.36 7.50 9.43 7.56 Module Efficiency(%) 17.9 18.2 18.5 18.8 19.1 STC (Standard Testing Conditions): Irradiance 1000W/ml, Cell Temperature 25 C, Spectra at AM1.5 NOCT (Nominal Operating Cell Temperature): Irradiance 800W/m2, Ambient Temperature 20 C, Spectra at AM1.5, Wind at 1m/5 Temperature Coefficient of Isc Temperature Coefficient of Voc Temperature Coefficient of Pmax +0.057%/ "C -0.286%/ "C -0.370%/ "C Current -Voltage Curve (LR6-60HPB-310M) 10• 6 - Cell Temp=25-C Cell Temp=35°C v V 4 - Cell Temp=45°C - Cell Temp=55°C 2 - Cell Temp=65°C Cell Temp=75°C 0 Voltage M L.ONGI Front Side Maximum Static Loading Rear Side Maximum Static Loading Hailstone Test Power -Voltage Curve (LR6-60HPB-310M) 350 Celltemp: 25°C -hcident Irrad. tO60W/m' 300 _hcident brad_ 6o6W/m' -Fcident Irrad �OOW/m' 250 -hcident lrtad.-000W/m' -hcident Irtad=200W/ 200 0 150 100 500 0 10 20 30 40 Voltage M 5400Pa 2400Pa 25mm Hailstone at the speed of 23m/s Current -Voltage Curve (LR6-60HPB-310M) 12 Centemp.25°C 10 Incident brad =t 000W/m' 8 1-dent Irrad: 600W/W 6 moment nrad.600W/m2 V 4 Incident Irrad.-0OOW/m' 2 Incident Irrad: 200W/m' 0 Voltage M Room 801, Tower 3, Lujiazui Financial Plaza, No.826 Century Avenue, Pudong Shanghai, 200120, China Tel: +86-21-80162606 E-mail: module@longi-silicon.com Facebook: www.facebook.com/LONGi Solar Note: Due to continuous technical innovation, R&D and improvement, technical data above mentioned may be of modification accordingly. LONGi Solar have the sole right to make such modification at anytime without further notice; Demanding party shall request for the latest datasheet for such as contract need, and make it a consisting and binding part of lawful documentation duly signed by both parties. V10 The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24 INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings¹ 235 W - 350 W + 235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³ 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 3 (X-IQ-AM1-240-3) To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • UL listed To learn more about Enphase offerings, visit enphase.com © 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the trademarks of Enphase Energy, Inc. 2019-11-04 MODEL NUMBER IQ Combiner 3 X-IQ-AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect™ CELLMODEM-03 (4G/12-year data plan) CELLMODEM-01 (3G/5-year data plan) CELLMODEM-M1 (4G based LTE-M/5-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Consumption Monitoring* CT CT-200-SPLIT Split core current transformers enable whole home consumption metering (+/- 2.5%). * Consumption monitoring is required for Enphase Storage Systems Wireless USB adapter COMMS-KIT-01 Installed at the IQ Envoy. For communications with Enphase Encharge™ storage and Enphase Enpower™ smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner™ and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240 Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64 A Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions (WxHxD)49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular Optional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included) COMPLIANCE Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 3 Rapid shutdown is built-in What’s new in NEC 2014? NEC 2014, Section 690.12 applies to PV conductors over 10 feet from the PV array and requires that the conductors power down to 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. Enphase® Energy // Rapid Shutdown ® To learn more, visit enphase.com The 2014 edition of the National Electrical Code (NEC 2014) added new rapid shutdown requirements for PV systems installed on buildings. Enphase Microinverters fully meet rapid shutdown requirements in the new code without the need to install any additional electrical equipment. Enphase comes standard with rapid shutdown capability Residential Microinverter Commercial Microinverter All Enphase microin- verters, even those that were previously installed, inherently meet rapid shutdown requirements, no additional equipment or workarounds needed Enphase microinverters can safely shut down automatically, leaving only low-voltage DC electricity isolated to the PV module String inverters require work arounds for rapid shutdown Residential String Inverter Commercial String Inverter Work around. Specialized Rapid Shutdown electrical box installed on the roof within 10 feet of array. Work around. String inverter installed on roof, a hostile environment that string inverters are not built to live in.Work around. Shutoff switch that is easily accessible to first responders on the ground. Work around. Extra conduit in installation. ALL TILE ROOF HOOK FOR SIDE MOUNT RAILS; ADJUSTABLE 17585 17586, 17587, 17588, 17589, 17618 AHJ CONDENSED PERMIT PACKAGE 2019 Version 2 A DIVISION OF QUICKSCREWS INTERNATIONAL CORP TABLE OF CONTENTS 3 SPEC SHEET QTY & MEASUREMENT INFORMATION 4 5 20 22 INSTALLATION INSTRUCTIONS STEP-BY-STEP-INSTALLATION GUIDE TEST RESULTS SUCH AS: WATER, UPLIFT, COMPRESSION, ETC. UL CERTIFICATION PROOF OF UL CERTIFICATION AZ TEST RESULTS SPECIFIC TESTING FOR ARIZONA COUNTIES Quickscrews International Corp. has changed the name of its solar division from SolarRoofHook to QuickBOLT 3 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. SPEC SHEET Letter Description Size/Length A Mounting Screw Slot 9mm x 18mm B Rail Slot Size 10mm x 71mm C Length of Roof Hook 179.5mm D Bottom End to Top End 190.3mm - 198.5mm E Thickness 6mm F Adjustability Range 34mm - 42mm Part #Box Quantity Screw Size 17585 10 Hooks N/A 17586 1 Hook N/A 17587 10 Hooks; 20 Screws 5/16” x 3” 17588 1 Hook; 2 Screws 5/16” x 3” 17589 10 Hooks; 20 Screws #14 x 3” 17618 1 Hook; 2 Screws #14 x 3” 4 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. INSTALL INSTRUCTIONS www.quickbolt.com 5 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. TEST RESULTS 6 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. Page 1 of 12 Project Number 115727C September 17,2015 Mr. RickGentry SolarRoofHook a division of Quickscrews International Corp 5830 Las Positas Road Livermore, CA 94583 Subject: QS# 17585 All Tile Roof Hook 90° Laboratory Load Testing Dear Mr. Gentry: As requested, Applied Materials & Engineering, Inc. (AME) has completed load-testing the All Tile Roof Hook 90° (see Appendix A, Figure 1). The purpose of our testing was to evaluate the compressive tensile (uplift) and shear (parallel to rafter) load capacity of the All Tile Roof Hook 90° attached to a 2"x4" Douglas Fir Rafter using two 5/16"Øx3" screws. SAMPLE DESCRIPTION Mockup samples were assembled in our laboratory on August 31, 2015. Mockup configuration consisted of three 12" long rafters at 4.5"o.c., screwed to 1/2" Structural I plywood. All Tile Roof Hook 90° is attached through the plywood into a rafter with two fasteners installed at the farthest end. TEST PROCEDURES & RESULTS 1. Compressive Load Test A total of three tests were conducted for compressive load capacity on September 11, 2015 using a United Universal testing machine. Samples were rigidly attached to the testing machine and a compressive load was applied to the hook. The samples were loaded in compression at a constant rate of axial deformation of 0.09 in. /min. without shock until the hook was bent and came in contact with the test board; displacement at maximum load was recorded. Based on the above testing, the average maximum compression load of the All Tile Roof Hook 90°attached to a 2"x4" Douglas Fir rafter using two 5/16"Øx3" screws was determined to be 395 lbf. Detailed results are provided in Table I. Test setup and mode of failure are provided in Appendix B, Figure 1. The specific gravity and moisture content of the rafter was tested in accordance with ASTM D2395, Method A (oven-dry). The specific gravity and moisture content were determined to be 0.379 and 10.0%, respectively. 7 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. 20 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. CERTIFICATE OF COMPLIANCE Certificate Number 20180725-E493748 Report Reference E493748-20170817 Issue Date 2018-JULY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 2 Issued to: SolarRoofHook, a Division of Quickscrews International Corp 5830 Las Positas Rd, Livermore CA 94551 This is to certify that representative samples of COMPONENT - MOUNTING SYSTEMS, MOUNTING DEVICES, CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Refer to Addendum Page for Models/Product. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 2703 Standard for Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. The UL Recognized Component Mark generally consists of the manufacturer’s identification and catalog number, model number or other product designation as specified under “Marking” for the particular Recognition as published in the appropriate UL Directory. As a supplementary means of identifying products that have been produced under UL’s Component Recognition Program, UL’s Recognized Component Mark: , may be used in conjunction with the required Recognized Marks. The Recognized Component Mark is required when specified in the UL Directory preceding the recognitions or under “Markings” for the individual recognitions. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. UL CERTIFICATION 21 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. CERTIFICATE OF COMPLIANCE Certificate Number 20180725-E493748 Report Reference E493748-20170817 Issue Date 2018-JULY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 2 of 2 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Models/Product USR – Component, Roof Mounting Hook Units, Models 15891 15893 15987 16000 16988 16990 16991 16993 17508 17509 17510 17511 1 7512 17513 17514 17515 17516 17517 17518 17519 17520 17521 17522 17523 17524 17525 17526 17527 17536 17537 17538 17539 17540 17541 17542 17543 17544 17545 17546 17547 17548 17549 17550 17551 17552 17553 17554 17555 17556 17558 17559 17560 17568 17569 17570 17571 17572 17573 17574 17575 17576 17577 17578 17579 17580 17585 17586 17587 17588 17589 17592 17596 17600 17601 17606 17607 17608 17609 17610 17611 17612 17613 17614 17615 17616 17617 17618 17620 17621 17622 17623 17624 17625 17626 17627 17628 17629 17630 17631 17632 17633 17636 17637 17638 17639 17642 17643 17646 17647 17648 17649 17650 17651 17659 17664 17667 17669 17670 17671 17672 17673 17678 17679 17680 17681 17686 17687 17688 17689 17700 17701 17702 17703 17704 17705 17706 17707 17708 17709 17710 1 7711 17712 17717 17718 17759 15891 -10 15891BLK-10 15987A 15987B 17667SS 17672SS 17680SS 17688SS 17713SS 17720 17721SS 17723 17724SS 17726 17727SS 17729 17730SS 15894SS 15891SS 15987BSS. 22 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. AZ TEST RESULTS Mr. Rick Gentry Quickscrews International SolarRoofHook.com 5830 Las Positas Road Livermore, CA 94551 Subject: Uplift, Compressive Load, and Lateral Load Test of QS #17586 (Kit #17618) 90 E All Tile Roof Hook with Slots and 8 mm Height Adjustment Range Dear Mr. Gentry, Per our service agreement, PNL has tested the 90 E All Tile Roof Hook with Slots and 8 mm Height Adjustment Range. The tests performed were a tensile load (uplift) test, compressive load test, and shear load (lateral load) test. A total of two roof hooks were tested for each load type. The samples submitted were the roof hook and screws from Kit #17618. The submitted sample materials are the same roof hook and screws in Part #17585, #17586, and Kit #17589. INITIAL SETUP Each roof hook was attached to a Douglas Fir 2"x4" using two #14 x 3" Solar Mounting Screws. The 2"x4" rafter and plywood test fixtures were assembled in our laboratory by using 5/16" x 3-1/8" RSS Rugged Structural screws to connect three 12 in. long 2"x4" douglas fir rafters to the 12 mm Birch plywood. Each 2"x4" rafter was connected to the plywood using two screws at each end of the 12 in. long 2"x4" (See Page 6 for photos and details). TEST PROCEDURE Tensile Load (Uplift) Test A total of two tests were conducted for tensile load (uplift) capacity on an Instron Universal Test Machine (UTM). The test samples were rigidly attached to the test machine using clamps and a tensile load was applied to the roof hook. The tensile load was applied at a constant rate of 0.09 in./min. without shock until failure. The load and displacement at failure were recorded and the failure mode was documented in photos. The average tensile load of the 90 E All Tile Roof Hook with Slots and 8 mm Height Adjustment Range attached to the 2"x4" using the #14 x 3" Solar Mounting screws was 1389 lbf. Additional details and photographs are supplied on page 3. Compressive Load Test A total of two tests were conducted for compressive load capacity on a UTM. The test samples were rigidly attached to the test machine using clamps and a compressive load was applied to the roof hook. The compressive load was applied at a constant rate of 0.09 in./min. without shock until the roof hook came into contact with the plywood base. The load and displacement at contact were Page 1 of 6 23 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. recorded and the failure mode was documented in photos. The average compressive load of the 90 E All Tile Roof Hook with Slots and 8 mm Height Adjustment Range attached to the 2"x4" using the #14 x 3" Solar Mounting screws was 340 lbf. Additional details and photographs are supplied on page 4. Shear Load (Lateral Load) Test A total of two tests were conducted for shear load (lateral load) capacity on a UTM. The test samples were rigidly attached to the test machine using clamps so that a compressive load could be applied to the roof hook in a direction parallel to the 2"x4" rafters. The shear load was applied at a constant rate of 0.09 in./min. without shock until the roof hook until failure. The load and displacement at tact were recorded and the failure mode was documented in photos. The average compressive load of the 90E All Tile Roof Hook with Slots 8 mm Height Adjustment Range attached to the 2"x4" using the #14 x 3" Solar Mounting screws was 420 lbf. Additional details and photographs are supplied on page 5. Respectfully Submitted, PHOENIX NATIONAL LABORATORIES, INC. __________________ Kyle Fleege, P.E. Project Manager PNL Ph: 602.431.8887 kyle@pnltest.com www.pnltest.com Page 2 of 6 24 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. LABORATORYTEST REPORT UPLIFT LOAD (TENSILE) 90E All Tile Roof Hook with Slots w/9 mm x 18 mm mounting screw slots CLIENT CLIENT PROJECT REF. NO.CLIENT ORDER NO. SolarRoofHook 17585, 17586, 17589, 17618 Per S.A. SAMPLE DESCRIPTION ROOF HOOK ID PRODUCT KIT ID 90E All Tile Roof Hook w/ Slots, 8 mm Height Adj.17585, 17586 17589, 17618 MATERIAL SUBMITTED BY PNL PROJECT NO.S.O. NO. PNL LAB NO. REPORT DATE Client 26-170169 001 ML827507 04/18/2017 TEST SPECIFICATIONS & EQUIPMENT INFORMATION TEMPERATURE:73E ±3EF HUMIDITY:50 ±5% EQUIPMENT MODEL:Instron 5985 SERIAL NO:5985U1246 LOAD CELL:50 kN (11,240 lbf)SERIAL NO:122570 TEST SPEED:0.09 in./min.FASTENER TYPE: #14 x 3" Solar Mounting Screws FASTENER LOCATION:Fasteners (Qty 2)installed in furthest slot point and secured to 2 x 4 running underneath plywood. TENSILE LOAD (UPLIFT) TEST DATA NO.MAXIMUM LOAD (lbf) DISPLACEMENT AT LOAD (in.)OBSERVATIONS 1 1179.7 5.691 Fastener pullout and permanent deformation failure. 2 1598.9 6.737 Fastener pullout and permanent deformation failure. AVG. 1389.3 6.214 PHOTOS Photo 1: Tensile Test Setup Photo 2: Tensile Test Setup Photo 3: Typical Failure Mode - Fastener Pullout Photo 4:Closeup of Fastener Pullout & Failure Page 3 of 6 25 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. LABORATORYTEST REPORT COMPRESSION LOAD 90E All Tile Roof Hook with Slots w/9 mm x 18 mm mounting screw slots CLIENT CLIENT PROJECT REF. NO.CLIENT ORDER NO. SolarRoofHook 17585, 17586, 17589, 17618 Per S.A. SAMPLE DESCRIPTION ROOF HOOK ID PRODUCT KIT ID 90E All Tile Roof Hook w/ Slots, 8 mm Height Adj.17585, 17586 17589, 17618 MATERIAL SUBMITTED BY PNL PROJECT NO.S.O. NO. PNL LAB NO. REPORT DATE Client 26-170169 001 ML827507 04/18/2017 TEST SPECIFICATIONS & EQUIPMENT INFORMATION TEMPERATURE:73E ±3EF HUMIDITY:50 ±5% EQUIPMENT MODEL:Instron 5985 SERIAL NO:5985U1246 LOAD CELL:10 kN (2,248 lbf)SERIAL NO:204786 TEST SPEED:0.09 in./min.FASTENER TYPE: #14 x 3" Solar Mounting Screws FASTENER LOCATION:Fasteners (Qty 2)installed in furthest slot point and secured to 2 x 4 running underneath plywood. COMPRESSION LOAD TEST DATA NO.MAXIMUM LOAD (lbf) DISPLACEMENT AT LOAD (in.)OBSERVATIONS 3 340.4 2.118 Test Hook permanently deformed and came into contact with plywood base. 4 339.6 2.156 Test Hook permanently deformed and came into contact with plywood base. AVG.340.0 2.137 PHOTOS Photo 5: Compression Test Setup Photo 6: Compression Test Setup Photo 7: Hook Contact with Plywood Photo 8: Typical Failure - Contact with Plywood Page 4 of 6 26 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. LABORATORYTEST REPORT SHEAR (LATERAL) LOAD 90E All Tile Roof Hook with Slots w/9 mm x 18 mm mounting screw slots CLIENT CLIENT PROJECT REF. NO.CLIENT ORDER NO. SolarRoofHook 17585, 17586, 17589, 17618 Per S.A. SAMPLE DESCRIPTION ROOF HOOK ID PRODUCT KIT ID 90E All Tile Roof Hook w/ Slots, 8 mm Height Adj.17585, 17586 17589, 17618 MATERIAL SUBMITTED BY PNL PROJECT NO.S.O. NO. PNL LAB NO. REPORT DATE Client 26-170169 001 ML827507 04/18/2017 TEST SPECIFICATIONS & EQUIPMENT INFORMATION TEMPERATURE:73E ±3EF HUMIDITY:50 ±5% EQUIPMENT MODEL:Instron 5985 SERIAL NO:5985U1246 LOAD CELL:10 kN (2,248 lbf)SERIAL NO:204786 TEST SPEED:0.09 in./min.FASTENER TYPE: #14 x 3" Solar Mounting Screws FASTENER LOCATION:Fasteners (Qty 2)installed in furthest slot point and secured to 2 x 4 running underneath plywood. SHEAR LOAD TEST DATA NO.MAXIMUM LOAD (lbf) DISPLACEMENT AT LOAD (in.)OBSERVATIONS 5 430.5 6.798 Permanent deformation of roof hook and screws. 1 screw head sheared off. 6 409.8 8.097 Permanent deformation of roof hook and screws. Both screws intact. AVG.420.2 7.448 PHOTOS Photo 9: Shear Test Setup Photo 10: Shear Test Setup Photo 11: Deformation and Rotation of Hook Photo 12: Failure of Screw Head Page 5 of 6 27 5830 Las Positas Road, Livermore CA 94551 | 3948 Airway Drive, Rock Hill SC 29732 Phone: (844) 671-6045 | Fax: (800) 689-7975 | www.quickbolt.com QuickBOLT is a division of Quickscrews International Corp. LABORATORYTEST REPORT CLIENT CLIENT PROJECT REF. NO.CLIENT ORDER NO. SolarRoofHook 17585, 17586, 17589, 17618 Per S.A. SAMPLE DESCRIPTION ROOF HOOK ID PRODUCT KIT ID 90E All Tile Roof Hook w/ Slots, 8 mm Height Adj.17585, 17586 17589, 17618 MATERIAL SUBMITTED BY PNL PROJECT NO.S.O. NO. PNL LAB NO. REPORT DATE Client 26-170169 001 ML827507 04/18/2017 TEST MOCKUP CONFIGURATION The base for the test assemblies was made from three 12 in. long Douglas Fir 2"x4"s screwed to 12 mm Birch plywood using 5/16" x 3-1/8" RSS Rugged Structural screws. The Roof Hooks were then attached using two of the Client provided #14 x 3" Solar Mounting Screws. On roof hooks that had multiple mounting screw slots, the screws were set at the furthest end of the furthest slot from the 90E section of the roof hook. The mounting screws were screwed through the plywood and into a 2"x4" underneath. On adjustable roof hooks, the 90E roof hook attachment was connected at one extreme end and the mounting screws were attached in screw slots at the opposite end. PHOTOS Photo 13: Test Mockup Base Assembly Photo 14: Fasteners for Plywood to 2x4: 5/16 x 3-1/8" RSS Rugged Structural Screws Photo 15: Douglas Fir 2x4 Product Tag Photo 16: Birch Plywood Product Tag Page 6 of 6 structural ENGINEERS January 7, 2020 SnapNrack 775 Fiero Lane, Ste. 200 San Luis Obispo, CA 93401 TEL: (877) 732-2860 Attn.: SnapNrack - Engineering Department Re: SnapNrack pre-engineered PV racking systems: • RL Universal System (Report # 2019-02916A.01 and B.01) • S200 Ground Mount System (Report # 2017-00240-D.02) • UR40 Railed System (Report # 2017-03227.11) • UR60 Railed System (Report # 2018-11940.03) Subject: Engineering certification for the State of California. PZSE, Inc. - Structural Engineers has provided engineering and span tables as presented in the above referenced reports. All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-10 & 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2016 & 2019 California Building Code, by California Building Standards Commission 3. 2016 & 2019 California Residential Code, by California Building Standards Commission 4. AC428 Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012, by ICC-ES 5. Aluminum Design manual 2015, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council This letter certifies that the design criteria and design methodology for the SnapNrack product span tables are in compliance with the above codes. Please refer to the system specific Engineering Certification Reports (listed above) for system specific design criteria and limitations. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. — Structural Engineers Roseville, CA 1478 Stone Point Drive, Suite 190, Roseville, CA 95661 T 916.961.3960 916.961.3965 www.pzse.com Experience snapnrack.com Ultra Rail Industry leading Wire Management Solutions An install experience unlike any other Mounts available for all roof types Compatible with all Series 100 Module Clamps & Accessories Start Installing Ultra Rail Today Ultra Rail The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.1 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management Open rail channel provides room for running wires resulting in a long-lasting quality install Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps System is fully bonded and listed to UL 2703 Standard © 2018 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com The SnapNrack Ultra Rail is a sleek, lightweight rail solution for mounting solar modules on the roof. The Entire System is a Snap to Install New Ultra Rail Mounts include snap-in brackets for attaching rail Compatible with all the SnapNrack Mid Clamps and End Clamps customers love Universal End Clamps and snap-in End Caps provide a clean look to the array edge The Largest Span Capabilities of any Light Rail Solution Ultra Rail, UR-40 Rail System Spans Wind (mph) 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 190 Sn o w ( p s f ) 0 5 10 15 20 25 30 35 40 45 50 60 70 80 90 100 110 120 System Span Key 6 ft Spans 4 ft Spans 2 ft Spans This table was prepared in compliance with applicable engineering codes and standards. Values are based on the following: ASCE 7-10 Chapter 30 Wind Loads & Chapter 7 Snow Loads Roof Slope: 7 - 27 deg Roof Height: 0 - 30 ft Exposure: B Roof Zone: 1 Module Orientation: Portrait Roof Type: Comp Visit SnapNrack.com for detailed span tables and certifi cations. snapnrack.com 877-732-2860 www.snapnrack.com contact@snapnrack.com Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy SnapNrack UL 2703 Fire Classification As of January 1st, 2015 many jurisdictions are now enforcing codes based upon updates to the International Building Code (IBC) and UL Standards 1703 (modules) and 2703 (mount- ing systems). The language included in the 2012 IBC requires that the combination of roof mounted solar modules and racking components is to be considered a system (IBC Section 1509.7.2). Additionally, it requires that this system shall meet or exceed the fire classifica- tion of the roof assembly. The objective is to ensure that the PV system does not adversely affect the fire rating of the roof. Roof sur- face fire ratings are classified either A, B, or C; Class A being the most resistant to the spread of flame. Since the physical characteristics of the PV module (material, thickness of glass, etc) also potentially af- fect how a fire will act, modules are now tested and assigned a “type” based upon these characteristics and spread of flame test results. There are 15 total module types, Types 1, 2 and 3 represent dif- ferences in the module composition and Types 4 – 15 are the same module compositions as Types 1 – 3 with differing fire test performance. SnapNrack Series 100, Ultra Rail and RL systems have been Certified for a Class A fire rating with Type 1 and Type 2 modules, in accordance with the standards set forth in UL1703/2703 and IBC 2012. In order to maintain this classification, the SnapNrack mounting systems must be installed per the UL-approved Installation Manuals. Because the test was conducted with the modules at 5 inches from the roof surface (worst case scenario), there is no restriction to the standoff height. Attachment 1 is the SnapNrack QIMS File which is accessed through the UL Online Certifica- tion Directory, or available here: SnapNrack QIMS File. March 2019 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 RAIL 232-02449, 232-02450, 232-02451 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH 232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 EQUIVALENT PROPERTIES A 0.357 in ² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP) 0.150 in³ Sx (BOT) 0.158 in³ Sy (LEFT) 0.175 in³ Sy (RIGHT) 0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 VIEW A-A SCALE 1 : 1 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES A A 1.78 2.45 1.78 6.00 3.00 1.64 1.68 1.36 1.21 .86 .20 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL MOUNTING HARDWARE 242-01229 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.19 OPTIONS: PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, SILVER11 5/16IN-18 X 2-1/4IN SS HCS BOLT12 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, SILVER13 SNAPNRACK, ULTRA RAIL MOUNT SPRING, SS14 SNAPNRACK, ULTRA RAIL MOUNT SPRING CAGE, 6061-T6 AL15 1 3 4 5 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL MOUNTING HARDWARE 242-01229 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: ALL DIMENSIONS IN INCHES 1.62 1.50P1.00 .38 .30 .07 1.37 1.50 .73