20-147 Encroachment Agreement, GTE Mobilnet of California Limited Partnership, dba Verizon Wireless, R.O.W, 19500 Pruneridge AvenueHeatherM. Minner
Kirsten Squarcia 11/12/20
T-1TITLE SHEETDRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/06/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_103(NEAR) 19500 PRUNERIDGE AVENUE CUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/11/20 100% CD PLAN CHECKSITE ID:SITE TYPE:POLE #:COUNTY:SF_CUPERTINO_103LIGHT POLENO POLE ID HSANTA CLARASF_CUPERTINO_103(NEAR) 19500 PRUNERIDGE AVENUE CUPERTINO, CA 95014SITE INFORMATIONSITE ADDRESS:OWNER:APPLICANT:LATITUDE:LONGITUDE:COUNTY:ASSESSORS PARCEL NUMBER:ZONING:ELEVATION:CITY OF CUPERTINO10300 TORRE AVECUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA 9459837.33379167 NAD83-122.0139528 NAD83SANTA CLARAPUBLIC RIGHT OF WAYNEAR 316-06-060CITY OF CUPERTINO169.2' AMSLVICINITY MAPPOLE PHOTONDRAWING INDEXT-1SHEET NO.TITLE SHEETT-2GENERAL NOTESA-1SITE PLAN & ENLARGED SITE PLANA-2A-4ELEVATIONSCIRCUIT DIAGRAMD-1DETAILSCODE COMPLIANCEALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENTEDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHINGIN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES.·2019 CALIFORNIA CODE·2019 CALIFORNIA BUILDING CODE (CBC), BASED ON THE 2018 IBC·2019 CALIFORNIA RESIDENTIAL CODE (CRC), BASED ON THE 2018 IRC·2019 CALIFORNIA ELECTRICAL CODE (CEC), BASED ON THE 2017 NEC·2019 CALIFORNIA MECHANICAL CODE (CMC), BASED ON THE 2018 UMC·2019 CALIFORNIA PLUMBING CODE (CPC), BASED ON THE 2018 UPC·2019 CALIFORNIA GREEN BUILDINGS STANDARDS CODE (CALGREEN)·2019 CALIFORNIA FIRE CODES WITH ALL LOCAL AMENDMENTS·ANY LOCAL BUILDING CODE AMENDMENTS TO THE ABOVE·CITY / COUNTY ORDINANCESSHEET TITLEE-1ELECTRICAL GENERAL NOTESE-2ONE-LINE DIAGRAM & GROUNDING SCHEMATIC E-3ELECTRICAL DETAILSACCESSIBILITY REQUIREMENTS FOR PERSONS WITH DISABILITIES:FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. ACCESSIBILITY ISNOT REQUIRED IN ACCORDANCE WITH CALIFORNIA ADMINISTRATIVE STATECODE PART 2, TITLE 24, CHAPTER 11B, SECTION 1103B.19500 PRUNERIDGEAVENUESURVEYPROJECT TEAMPROJECT DESCRIPTIOND-2DETAILSTHE UTILITIES SHOWN HEREIN ARE FOR THE CONTRACTORS CONVENIENCEONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THEENGINEER/SURVEYOR ASSUMES NO RESPONSIBILITY FOR THE LOCATIONSSHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFYALL THE UTILITIES WITHIN THE LIMITS OF THE WORK. ALL DAMAGE MADE TOTHE (E) UTILITIES BY THE CONTRACTOR SHALL BE THE SOLE RESPONSIBILITYOF THE CONTRACTOR.CALL 811 BEFORE YOU DIGIT'S THE LAWMODUS PROJECT MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMCONSTRUCTION/IMPLEMENTATION MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMA&E PROJECT MANAGER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMAPPLICANT:VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA 94598CONTACT: CHRIS MOLLERPHONE: (925) 339.2778EMAIL: CHRIS.MOLLER@VERIZONWIRELESS.COMLAND USE PLANNER:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COMSITE ACQUISITION:MODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA 94108PHONE: (415) 989.1102EMAIL: VERIZONPOLYGONTEAM@MODUSLLC.COM(NEAR) 19500 PRUNERIDGE AVENUE CUPERTINO, CA 95014SITED-3DETAILSC-1A-3ELEVATIONSVERIZON WIRELESS PROPOSES TO INSTALL A NEW WIRELESS COMMUNICATION SITE ON A LIGHT POLE IN THE PUBLIC RIGHT-OF-WAY.SCOPE:·INSTALL (1) 2' NEW CANISTER ANTENNA INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE·INSTALL (2) 5G ANTENNA/RADIOS INSIDE NEW FRP CONCEALMENT SHROUD ON TOP OF POLE·INSTALL (1) RRUS 8843, (1) RRUS 4408, (1) RRUS 2205 RADIOS IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL (2) PSU-AC08 BEHIND RADIOS IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL NEW COAX FROM EQUIPMENT TO NEW ANTENNA WITHIN POLE·INSTALL (1) NEW DISCONNECT / SMART METER ON SIDE OF POLE·INSTALL (1) NEW AC LOAD CENTER IN EQUIPMENT CONCEALED PEDESTAL BASE·INSTALL NEW PEDESTAL BASE POLE AND FOUNDATION TO REPLACE EXISTING
FIBERS/LS/L S/L S/LFIBERFIBER
DRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/06/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_103(NEAR) 19500 PRUNERIDGE AVENUE CUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/11/20 100% CD PLAN CHECK207/22/20 100% CD PLAN CHECKA-1SITE PLAN1ENLARGED SITE PLANNSITE PLAN2N2A-1ENLARGED SITE PLANA.P.N.:316-06-060(E) SIDEWALK
1/16"=1'-0"SCALE1/2"=1'-0"SCALE1&2A-21&2A-3(N) LOCATION OF VERIZONWIRELESS CANISTER ANTENNA IN FRPSHROUD MOUNTED ON LIGHT POLE(N) LOCATION OF VERIZON WIRELESSEQUIPMENT MOUNTED ON LIGHT POLEPROPER
T
Y
L
I
N
E (E) CURB & GUTTER(E) TREE15'-0"± CENTER OF POLE TO ROW LINE(N) LOCATION OF VERIZONWIRELESS CANISTERANTENNA AND EQUIPMENTNORTH WOLFE ROAD
(E) BUILDINGELECTRICAL LINESTREET LIGHT LINE ES/LFIBER LINE(S)FIBERLEGENDEC1(E) STEEL MAST ARM TO BERELOCATED ON (N) LIGHT POLE(E) LUMINAIREE1N1EC2NC2NC3(N) EQUIPMENT CONCEALED PEDESTALBASE BY MANUFACTURER(E) TREE(E) TREE, TYP.
PROP
E
R
T
Y
L
I
N
E
(E) SI
D
E
W
A
L
K
PROPERTY LINE
(E) MANHOLE
NORTH WOLFE ROAD
(E) PULL BOX(E) STREET LIGHT(E) CURB & GUTTER15'-0"± CENTER OFPOLE TO ROW LINE13'-9"± BACK OF CABINET TO ROW LINENOTES:1. OLD FOUNDATION BASE TO BE FILLED WITHCONTROLLED DENSITY FILL TO WITHIN 12" OFFINISH GRADE. CAP WITH PLANTING SOIL.2. LANDSCAPE AND IRRIGATION TO BERESTORED TO MATCH EXISTING FINISHELEVATIONS222(E) LIGHT POLE AND FOUNDATION TO BE REMOVED. (N)LIGHT POLE & FOUNDATION TO BE INSTALLED IN PLACENC1
UPDATED 9-4-2020
SHUTDOWNDRAWN BY:CHECKED BY:BMAPEIT IS A VIOLATION OF THE LAW FOR ANY PERSON, UNLESSTHEY ARE ACTING UNDER THE DIRECTION OF A LICENSEDPROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT004/06/20100% CDREVDATEDESCRIPTIONMODUS, LLC240 STOCKTON ST., 3RD FLOORSAN FRANCISCO, CA94108APPROVED BY:LJBSF_CUPERTINO_103(NEAR) 19500 PRUNERIDGE AVENUE CUPERTINO, CA 95014VERIZON WIRELESS2785 MITCHELL DRIVE, SUITE 9WALNUT CREEK, CA94598105/11/20 100% CD PLAN CHECK207/22/20 100% CD PLAN CHECKA-2EXISTING & PROPOSEDELEVATIONS12PROPOSED ELEVATIONEXISTING ELEVATION1/2"=1'-0"SCALE1/2"=1'-0"SCALEEXISTING SURFACE0'-0" AGLEXISTING SURFACE0'-0" AGL(N) LIGHT POLE(E) FOUNDATION TO BE REPLACED(E) LIGHT POLE TO BE REPLACED(E) LUMINAIRE(E) ROAD SIGN(E) ROAD SIGN13'-9" BACK OF CABINET TO ROW LINET.O. (N) EQUIPMENT ENCLOSURE4'-0" AGLB.O. (E) ROAD SIGN6'-10" AGLT.O. (E) ROAD SIGN8'-4" AGLT.O. (E) LIGHT SENSOR39'-0" AGLB.O. (E) LIGHT ARM34'-7" AGLT.O. (E) STEEL LIGHT POLE35'-2" AGL15'-0" CENTER OF POLE TO ROW LINE4D-2(N) FOUNDATION(E) LUMINAIRE(N) NOTICE SIGNAGEFACING STREETSIDE12D-1(E) RELOCATED MAST ARMT.O. (N) STEEL LIGHT POLE29'-11" AGLT.O. (N) LIGHT SENSOR32'-10" AGL(N) (2) 5G ANTENNASIN FRP SHROUD6D-1(N) VERIZON WIRELESSCANISTER ANTENNA4D-1(N) FRP CONCEALMENTSHROUD1D-1RAD CENTER OF (P) 5G ANTENNA31'-7" AGLT.O. (P) CONCEALMENT SHROUD35'-6" AGLRAD CENTER OF (P) CANISTER ANTENNA34'-3" AGLT.O. (N) NOTICE SIGNAGE24'-9" AGLT.O. (E) ROAD SIGN6'-10" AGLT.O. (E) ROAD SIGN8'-4" AGL7D-18D-15D-111D-1(N) VERIZON WIRELESS EQUIPMENT CONCEALEDWITHIN PEDESTAL BASE-(1) RRUS 8843, (1) 4408, (1) 2205-(2) PSU AC08-(1) AC LOAD CENTER-(1) TWIN DIPLEXER-(1) FIBER DEMARC BOX4E-31D-23E-3B.O. (N) DISCONNECT7'-0" AGLT.O. (N) DISCONNECT8'-9" AGL(N) SMART METER / DISCONNECTw/ SHUTDOWN SIGNAGE4D-310D-19D-13D-1PORT HOLE LOCATIONFOR DISCONNECT5D-3NOTES:1. ALL NEW ANTENNAS, BRACKETS, AND OTHER EQUIPMENTWILL BE PAINTED TO MATCH LIGHT POLE.2. ALL EXISTING SIGNAGE TO BE RELOCATED SHALL BEFASTENED USING STEEL BANDING PER SHEET T-2.(E) LIGHT ARM MASTTO BE RELOCATEDTO (N) LIGHT POLE2UPDATED 9-4-2020
Encroachment Agreement - Cuper 103.planshts
Final Audit Report 2020-11-12
Created:2020-10-29
By:Julia Kinst (juliak@cupertino.org)
Status:Signed
Transaction ID:CBJCHBCAABAALVmDjMx4icIgTdHuKXFYAbODF48lqVL7
"Encroachment Agreement - Cuper 103.planshts" History
Document created by Julia Kinst (juliak@cupertino.org)
2020-10-29 - 5:28:54 PM GMT- IP address: 64.165.34.3
Document emailed to HeatherM. Minner (minner@smwlaw.com) for signature
2020-10-29 - 5:29:46 PM GMT
Email viewed by HeatherM. Minner (minner@smwlaw.com)
2020-11-12 - 5:45:06 PM GMT- IP address: 104.143.198.23
Document e-signed by HeatherM. Minner (minner@smwlaw.com)
Signature Date: 2020-11-12 - 5:45:35 PM GMT - Time Source: server- IP address: 52.39.49.65
Document emailed to Chad Mosley (chadm@cupertino.org) for signature
2020-11-12 - 5:45:37 PM GMT
Email viewed by Chad Mosley (chadm@cupertino.org)
2020-11-12 - 7:08:07 PM GMT- IP address: 104.47.44.254
Document e-signed by Chad Mosley (chadm@cupertino.org)
Signature Date: 2020-11-12 - 7:08:23 PM GMT - Time Source: server- IP address: 67.164.60.110
Document emailed to Kirsten Squarcia 11/12/20 (kirstens@cupertino.org) for signature
2020-11-12 - 7:08:25 PM GMT
Email viewed by Kirsten Squarcia 11/12/20 (kirstens@cupertino.org)
2020-11-12 - 7:31:43 PM GMT- IP address: 104.47.45.254
Document e-signed by Kirsten Squarcia 11/12/20 (kirstens@cupertino.org)
Signature Date: 2020-11-12 - 7:32:13 PM GMT - Time Source: server- IP address: 148.64.105.190
Agreement completed.
2020-11-12 - 7:32:13 PM GMT