binder1APPLICABLE CODES THE FOLLOWING GOVERN THE CONSTRUCTION OF THE WORK, ALL SHALL BE CURRENT ENFORCED EDITIONS A. 2019 CALIFORNIA BUILDING CODE B. 2019 CALIFORNIA ELECTRICAL CODE C. 2019 CALIFORNIA MECHANICAL CODE D. 2019 CALIFORNIA PLUMBING CODE E. 2019 CALIFORNIA ENERGY CODE F. 2019 CALIFORNIA FIRE CODE G. 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE H. ALL LOCALLY ADOPTED AMENDMENTS TO THE ABOVE 'NOTED CODES' J. THE CITY OF CUPERTINO STANDARDS, SPECIFICATIONS, DETAILS AND APPLICABLE REGULATIONS K. OTHER APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS SOURCE: CALIFORNIA BUILDING STANDARDS COMMISSION AND AT ANGLE CHANNEL GREATER THAN LESS THAN GREATER THAN OR EQUAL TO LESS THAN OR EQUAL TO PLUS OR MINUS ARCHITECT / ENGINEER ANCHOR BOLT AIR CONDITIONING ASPHALT COMPOSITION ACOUSTICAL AMERICANS WITH DISABILITIES ACT ADJACENT ABOVE FINISHED FLOOR ABOVE FINISHED SLAB AGGREGATE ALUMINUM ALTERNATE ANODIZED AMERICAN NATIONAL STANDARDS INSTITUTE APPROXIMATE(LY) ARCHITECT(URAL) ASPHALT ASSEMBLY AMERICAN SOCIETY FOR TESTING AND MATERIALS ARCHITECTURAL WOODWORKING INSTITUTE AUDIO VIDEO BOARD BUILDING BUILDING STANDARD BLOCK BLOCKING BEAM BOTTOM BRASS BRITISH THERMAL UNIT BUILT-UP CABINET CALIFORNIA BUILDING CODE CEMENT CEMENT PLASTER CERAMIC CAST IRON CONTROL JOINT CENTER LINE CEILING CLEAR CALIFORNIA MECHANICAL CODE CONCRETE MASONARY UNIT CLEANOUT COLUMN CONCRETE CONFERENCE CONNNECTION CONSTRUCTION CONTINUOUS CONTRACTOR COORDINATE CALIFORNIA PLUMBING CODE CARPET CERAMIC TILE INSTITUTE OF AMERICA CENTER COLD WATER DOUBLE DEDICATED DEGREE DELETE DEMOLITION DEPARTMENT DETAIL DRINKING FOUNTAIN DOOR AND HARDWARE INSTITUTE DIAMETER DIFFUSER DIMENSION DISPENSER DOWN DOOR DRY STAND PIPE DISHWASHER DRAWING(S) DRAWER EAST EXISTING TO REMAIN EACH EXHUAST FAN EXPANSION JOINT ELEVATION ELECTRIC OR ELECTRICAL ELEVATOR/ELEVATION EMERGENCY ELECTRICAL PANELBOARD EQUAL EQUIPMENT ESTIMATE EACH WAY ELECTRIC WATER COOLER EXISTING EXTERIOR FIRE ALARM FLAT BAR FLOOR DRAIN FOUNDATION FIRE EXTIGUISHER FIRE EXTIGUISHER CABINET FIRE HOUSE CABINET FINISH FINISH FLOOR FLOOR FLOURESCENT FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF STUDS FIREPROOF OR FIREPROOFING FIRE RESISTANT FOOT / FEET FOOTING FURNITURE GAUGE GALVANIZED GRAB BAR GLUE GLUE LAMINATED (BEAM) GRADE GYPSUM HAZARDOUS MATERIALS HOSE BIBB HOLLOW CORE HARDWOOD HARDWARE HOLLOW METAL HOLD-OPEN HORIZONTAL HOT WATER HEIGHT HORESPOWER HOUR INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS INSIDE DIAMETER INCH OR INCHES INFORMATION INTERIOR JANITOR OR JANITOR CLOSET JUNCTION BOX JOINT KNOCKED DOWN KITCHEN LAMINATE LAVATORY LIGHTING MANUAL MATERIAL MAXIMUM MECHANICAL MEZZANINE MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL & @ L [ > < > < ± A/E AB A/C AC ACOUS ADA ADJ AFF AFS AGGR AL ALT ANOD ANSI APPROX ARCH ASPH ASSY ASTM AWI AV BD BLDG BLDG STD BLK BLKG BM BOT BR BTU BU CAB CBC CEM CEM PLAS CER CI CJ CL CLG CLR CMC CMU CO COL CONC CONF CONN CONSTR CONT CONTR COORD CPC CPT CTI CTR CW DBL DED DEG DEL DEMO DEPT DET DF DHI DIA OR Ø DIFF DIM DISP DN DR DSP DW DWG(S) DWR E (E)/EXIST EA EF EJ EL ELEC ELEV EMER EP EQ EQUIP EST EW EWC EXIST EXT FA FB FD FDN FE FEC FHC FIN FIN FL FLR FLUOR FOC FOF FOM FOS FPRF FR FT FTG FURN GA GALV GB GL GLULAM GR GYP HAZ MAT HB HC HDWD HDWE HM HO HORIZ HW HT HP HR ICBO ID IN INFO INT JAN JB JT KD KIT LAM LAV LTG MAN MATL MAX MECH MEZZ MFG MFR MIN MISC MTD MTL NORTH NEW NOT APPLICABLE NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATIONAL ROOFING CONTRACTORS ASSOCIATION NOT TO SCALE ON CENTER OUTSIDE DIMENSION/DIAMETER OUTSIDE FACE OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OWNER INSTALLED OWNER FURNISHED/OWNER INSTALLED OPPOSITE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PERPENDICULAR PROPERTY LINE PLASTIC LAMINATE PLYWOOD PAIR PREFABRICATED PREFINISHED PRELIMINARY QUANTITY QUALITY RELOCATE OR REMOVE RISER OR RATED RETURN AIR RADIUS RESILIENT BASE REINFORCED CONCRETE REFLECTED CEILING PLAN ROOF DRAIN RECESSED REFERENCE REINFORCE(D) (ING) (MENT) REQUIRED REQUIREMENTS RESILIENT FLOORING ROOM ROUGH OPENING RAIN WATER LEADER SOUTH SUPPLY AIR STORM DRAIN STEEL DOOR INSTITUTE SECTION SHEET SHEATHING SIMILAR SHEET METAL SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SEE CIVIL DRAWINGS SEE ELECTRICAL DRAWINGS SEE MECHANICAL DRAWINGS SEE PLUMBING DRAWINGS SEE STRUCTURAL DRAWINGS SPECIFICATION SQUARE SQUARE FEET SQUARE INCH SQUARE YARD STAINLESS STEEL STANDARD STEEL SUSPENDED SYSTEM THERMOSTAT TONGUE AND GROOVE TO BE DETERMINED TELEPHONE TEMPERED OR TEMPURATURE TEMPERED GLASS TERRAZZO THICK OR THICKNESS THRESHOLD THROUGH TOP OF CONCRETE TOP OF STEEL TOP OF WALL TOILET PAPER DISPENSER TUBE STEEL TYPICAL UNDERWRITERS LABORATORIES UNFINISHED UNLESS OTHERWISE NOTED URINAL UTILITY VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD WIDTH OR WIDE WITH WITHOUT WHITE BOARD WOOD BLOCKING WATER CLOSET WOOD WATER HEATER WEIGHT YARD(S) N (N) NA NEC NEMA NIC NFPA NRCA NTS OC OD OF OFCI OFOI OFOI OPP OSHA PERP PL PLAM PLYWD PR PREFAB PREFIN PRELIM QTY QUAL (R) R RA RAD RB RC RCP RD REC REF REINF REQD REQS RF RM RO RWL S SA SD SDI SECT SHT SHTHG SIM SM SMACNA SCD SED SMD SPD SSD SPEC(S) SQ SG FT SQ IN SQ YD SS STD STL SUSP SYS T T&G TBD TEL TEMP TEMP GL TERR THK THRES THRU TOC TOS TOW TPD TS TYP U.L. UNFIN UON UR UTIL VCT VERT VEST VIF W W/ W/O WB WBL WC WD WH WT YD(S) 1. AT LEAST 65% OF CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED. CONSTRUCTION AND DEMOLITION (C&D) DEBRIS INCLUDING CONCRETE, GYPSUM WALLBOARD, CARDBOARD, CERAMIC TILE, CARPETING, FIXTURES, PLASTIC PIPE, METALS, AND CEILING TILE, MUST BE TRANSPORTED OFF SITE BY A REGISTERED TRANSPORTER AND TAKEN TO A REGISTERED FACILITY THAT CAN PROCESS MIXED C&D DEBRIS AND DIVERT A MINIMUM OF 50% OF THE MATERIAL FROM LANDFILL. C&D MATERIALS SOURCE- SEPARATED AT THE CONSTRUCTION SITE FOR REUSE OR RECYCLING MUST BE TAKEN TO A FACILITY THAT REUSES OR RECYCLES THOSE MATERIALS. 2. ALL MATERIALS, LABOR, INSTALLATION, FABRICATION, ETC. SHALL CONFORM TO ALL LOCAL CODES, REGULATIONS AND TITLE 24 C.A.C. INCLUDING THOSE ABSTRACTS DEALING WITH ENERGY AND DISABLED ACCESS REQUIREMENTS. 3. ALL WORK INDICATED TO BE PROVIDED SHALL BE NEW, U.O.N. 4. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. 5. ALL CONSTRUCTION DOCUMENTS ARE COMPLIMENTARY, AND WHAT IS CALLED FOR BY ANY WILL BE AS BINDING AS IF CALLED FOR BY ALL. ANY WORK SHOWN OR REFERRED TO ON ANY CONSTRUCTION DOCUMENT SHALL BE PROVIDED AS THOUGH ON ALL RELATED DOCUMENTS. THE CONSTRUCTION DOCUMENTS ARE PROVIDED TO ILLUSTRATE THE DESIGN AND GENERAL TYPE OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. THE GENERAL CONTRACTOR IN ASSUMING RESPONSIBILITY FOR THE WORK INDICATED, SHALL COMPLY WITH THE SPIRIT AS WELL AS THE LETTER IN WHICH THEY WERE WRITTEN. 6. ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR, EXCEPT WHERE NOTED OTHER WISE. THE GENERAL CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER CONTRACTORS OR VENDORS TO ASSURE THAT ALL SCHEDULES ARE MET AND THAT ALL WORK IS DONE IN CONFORMANCE TO MANUFACTURER'S REQUIREMENTS. 7. MATERIALS ARE SPECIFIED BY THEIR BRAND AND/OR PRODUCT NAMES TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE. ANY REQUEST FOR SUBSTITUTION SHALL BE SUBMITTED TO ARCHITECT TO DETERMINE EQUAL QUALITY AND PERFORMANCE. SUBSTITUTIONS SHALL NOT BE PURCHASED OR INSTALLED WITHOUT ARCHITECT'S ADVANCE, WRITTEN APPROVAL. 8. ALL WORK INDICATED TO BE PROVIDED SHALL BE NEW UNLESS SPECIFICALLY NOTED OTHERWISE. 9. ALL DIMENSIONS ON ARE FROM FACE OF FINISH, (U.O.N.). CONTRACTOR SHALL NOT SCALE DRAWINGS. DIMENSIONS ON DRAWINGS TAKE PRECEDENCE OVER SCALE. 10. DIMENSION DEFINITIONS: CLEAR : FOR EQUIPMENT OR DISABLED CLEARANCES AND MUST BE MAINTAINED. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. HOLD : ARE CRITICAL DIMENSIONS TO BE MET IN THE LAYOUT; NO VARIATION IS ACCEPTABLE. V.I.F. : VERIFY STATED DIMENSION IN FIELD PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. A.F.F. : ELEVATION HEIGHT ABOVE FACE OF FINISH FLOOR 11. ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO START OF CONSTRUCTION. 1. ANY NECESSARY MODIFICATIONS TO THE EXISTING FIRE SPRINKLER SYSTEM 2. FIRE ALARM ARCHITECT Apple One Apple Park Way Cupertino, CA 95014 David Whitney Architects, Inc. 2185 The Alameda, Ste. 100 San Jose, California 95126 Melanie N. Maravilla 408.726.8076 mnarvaez@apple.com David Whitney 408.627.9123 david@davidwhitneyarch.com MECHANICAL ENGINEER Deharo Mechanical Inc. 280 Cochrane Cir Morgan Hill, California 95037 Kyle Sakai 408.627.1089 kyle@deharomechanical.com GENERAL CONTRACTOR Reliable Concepts Corporation 954 Chestnut St San Jose, California 95110 BUILDING ADDRESS: ONE INFINITE LOOP CUPERTINO, CA 95014 TYPE OF CONSTRUCTION: I-A SPRINKLERED: FULLY SPRINKLERED OCCUPANCY GROUPS: B -OFFICE, A-3, S USE:OFFICE NUMBER OF STORIES:FOUR STORY WITH BASEMENT FLOOR AREA FIRST FLOOR (E) AREA: 51,097 SQ.FT AREA OF WORK: 370 SQ.FT ZONING:P (CG, ML, OA) APN #:316-02-105 SCOPE OF WORK DEFERRED SUBMITTAL PROJECT DIRECTORY PROJECT DATAGENERAL NOTESABBREVIATIONS THIS IS AN INTERIOR TENANT IMPROVEMENT IN AN EXISTING COMMERCIAL OFFICE BUILDING ON THE FIRST FLOOR TO CONSOLIDATE THREE ROOMS INTO ONE LARGER OFFICE. THERE IS NO CHANGE OF USE OR EXTERIOR WORK. SITE IMPROVEMENTS ARE UNDER A SEPERATE PERMIT #B-2019-0093 THE CAMPUS HAS BEEN DECOMPARTMENTALIZED PER PERMIT #12070032 A 1 A101 1 1 1 SIM A11.01 A COLUMN GRID ROOM NUMBER ELEVATION, CONTROL OR DATUM POINT REVISION REFERENCE DESCRIPTION OF SIMILAR OR OPPOSITE LOCATION ON ROW WHERE SHOWN AREA TO BE DETAILED SHEET WHERE SHOWN DETAIL NUMBER SHEET WHERE SHOWN DIRECTION OF ELEVATION 509 OFFICE PROJECT SYMBOL LEGEND A101 1 SHEET WHERE SHOWN DETAIL NUMBER ROOM NAME KEYNOTE VICINITY MAP PROJECT LOCATION Daniel H. Montes Alberto Delgadillo 408.593.4051 408.590.4819 dhmontes@rcc-bgm.com adelgadillo@rcc-bgm.com ELECTRICAL ENGINEER Anthony Jones 925.989.9954 ajones@tmarshall.comT. Marshall Associates 7042-B Commerce Circle Pleasanton, California 94588 BUILDING OWNER/PROJECT MANAGER FIRE NOTES 1. ALL CONSTRUCTION SITES MUST COMPLY WITH APPLICABLE PROVISIONS OF CFC CHAPTER 33 AND SCCFD'S SPECIFICATION SI-7 -CONSTRUCTION SITE FIRE SAFETY. 2. FIRE DEPARTMENT ACCESS TO THE SITE, THE BUILDING, AND TO ALL FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED AT ALL TIMES, IN ACCORDANCE WITH CFC CHAPTER 5. 3. ALL DOORS PROVIDED WITH CARD READER ACCESS CONTROLS SHALL BE PROVIDED WITH A MEANS TO BE UNLOCKED BY EMERGENCY PERSONNEL FROM A SINGLE LOCATION INSIDE THE MAIN ENTRANCE TO THE BUILDING, IN ACCORDANCE WITH SCCFD'S STANDARD DETAIL AND SPECIFICATION SI-6. E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m 1/8" = 1'-0" 6/ 4 / 2 0 2 1 1 1 : 5 8 : 0 1 A M A0.00 One Infinite Loop Cupertino, CA 95014 SHEET INDEX - PROJECT INFO AP21.01 Author IL01.1N SHEET INDEX LEGEND: ● SHEET ISSUED WITH REVISION ○ SHEET ISSUED IN PREVIOUS REVISION ▲ SHEET REMOVED FROM SCOPE SH E E T N U M B E R SHEET NAME 20 2 1 . 0 4 . 3 0 I S S U E F O R P E R M I T 20 2 1 . 0 6 . 0 4 P L A N C H E C K R E S P . 1 REMARKS ARCHITECTURAL A0.00 SHEET INDEX - PROJECT INFO ● ● A0.01 CONSTRUCTION BEST MANAGEMENT ● A0.02 CALGREEN CHECKLIST ● A0.50 LIFE SAFETY PLAN ● ● A1.10 DEMOLITION PLAN & RCP ● A2.10 PARTITION PLAN & RCP ● A4.10 POWER, DATA & FINISH PLAN ● A6.10 INTERIOR ELEVATION, DOOR SCHEDULE & DETAILS ● A8.00 ENLARGED RESTROOM PLAN & ELEVATIONS ● ● A8.01 ACCESSIBLE RESTROOM DETAILS ● ● R-A0.5.S1 1991 IL CAMPUS EGRESS PLAN ● FOR REFERENCE ONLY R-C5.0 SURFACE PARKING & ADA PATH SITE PLAN ● FOR REFERENCE ONLY MECHANICAL M0.0 MECHANICAL COVER SHEET ● M1.0 MECHANICAL DEMO PLAN ● M2.0 MECHANICAL PLAN ● ELECTRICAL E0.1 DRAWING INDEX, SYMBOL LIST, GENERAL NOTES, SINGLE LINE DIAGRAM NOTE, PROJECT VICINITY MAP ● E1.1 APPLE IL01.1N L1 BUILDING FLOOR PLAN, AREA OF WORK ● E1.2A ELECTRICAL DETAILS ● E2.1 APPLE ROOM A141 POWER PLAN, SCHEDULES, DETAILS, PANEL SCHEDULE ● E3.1 APPLE ROOM A141 LIGHTING PLAN, SCHEDULES, DETAILS ● E3.2 CA 2019 ENERGY CODE SECTION 130.0 COMPLIANCE FORMS, LIGHTING FIXTURE SCHEDULE ● NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT 2021.04.30 1 PLAN CHECK RESP. 1 2021.06.04 Arnold Hom 06/23/21 06/24/21 BLD-2021-0818 Haley McKee E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m 4/ 3 0 / 2 0 2 1 6 : 2 4 : 5 6 P M A0.01 One Infinite Loop Cupertino, CA 95014 CONSTRUCTION BEST MANAGEMENT AP21.01 Author IL01.1N NO. DESCRIPTION: DATE: ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 NEWLY INSTALLED FIXTURES IN THE PROJECT AREA MUST COMPLY WITH PRESCRIPTIVE FIXTURE AND FITTING FLOW RATES BELOW. NOTES: 1. FOR DUAL FLUSH TOILETS, EFFECTIVE FLUSH VOLUME IS DEFINED AS THE AVERAGE VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSH. THE REFERENCE STANDARD IS ASME A112.19.14 AND USEPA WATERSENSE TANK-TYPE HIGH EFFICIENCY TOILET SPECIFICATION -1.28 GAL (4.8 L). 2. THE COMBINED FLOW RATE OF ALL SHOWERHEADS IN ONE SHOWER STALL SHALL NOT EXCEED THE MAXIMUM FLOW RATE FOR ONE SHOWERHEAD, OR THE SHOWER SHALL BE DESIGNED TO ALLOW ONLY ONE SHOWERHEAD TO BE IN OPERATION AT A TIME (CALGREEN 5.303.3.3) 1. SUSTAINABILITY NOTES 2. WATER EFFICIENCY 3. ENERGY & ATMOSPHERE 4. ADHESIVES, SEALANTS, CAULKS & PAINTS 5. MECHANICAL, ELECTRICAL & PLUMBING 6. INDOOR WATER USE 7. INDOOR ENVIRONMENTAL QUALITY 8. MATERIALS & RESOURCES 1. WHERE COMMISSIONING IS REQUIRED CONTRACTOR TO PROVIDE COMPLETED CHECKLISTS TO THE COMMISSIONING AUTHORITY OF ALL COMMISSIONED SYSTEMS & ASSEMBLIES. CHECKLISTS TO BE PROVIDED IN A TIMELY MANNER IN CONJUNCTION WITH ONGOING SITE VISITS BY COMMISSIONING AGENT TO VERIFY PROPER INSTALLATION OF THESE SYSTEMS & ASSEMBLIES. 2. CONTRACTOR SHALL DEVELOP A WRITTEN PLAN FOR TESTING AND ADJUSTING SYSTEMS AS APPLICABLE TO THE PROJECT. THESE SYSTEMS COULD INCLUDE HVAC SYSTEMS AND CONTROLS, INDOOR AND OUTDOOR LIGHTING AND CONTROLS, WATER HEATING SYSTEMS, RENEWABLE ENERGY SYSTEMS, LANDSCAPE IRRIGATION SYSTEMS AND WATER REUSE SYSTEMS. PROVIDE A REPORT INDICATING ALL NEWLY INSTALLED EQUIPMENT HAS BEEN TESTED AND ADJUSTED IN ACCORDANCE WITH INDUSTRY BEST PRACTICES AND APPLICABLE STANDARDS ON EACH SYSTEM. 3. CONTRACTOR TO COORDINATE WITH OWNER & COMMISSIONING AUTHORITY IN CREATING OPERATION & MAINTENANCE MANUALS FOR THE OWNER'S USE. TEAM TO MEET PRIOR TO CONSTRUCTION TO DETERMINE AND ASSIGN RESPONSIBILITIES FOR COMPLETION & REVIEW OF ALL MANUALS. 4. CONTRACTOR TO ASSEMBLE & RETAIN ALL EQUIPMENT SCHEDULES & CUTSHEETS HIGHLIGHTING REFRIGERANT INFORMATION FOR ALL NEW HVAC&R COMPONENTS. 5. CONTRACTOR, IN COORDINATION WITH PROJECT TEAM, TO AID IN THE DEVELOPMENT OF A SCHEDULE OF MECHANICAL EQUIPMENT USED IN PROJECT WITH BOTH ACTUAL & E-BENCHMARK EFFICIENCY REQUIREMENTS. MANUFACTURER'S INFORMATION TO BE ASSEMBLED TO CONFIRM PERFORMANCE. 6. CONTRACTOR, IN COORDINATION WITH PROJECT TEAM, TO RETAIN CONFIRMING INFORMATION THAT APPLIANCES & EQUIPMENT ARE ENERGY STAR LISTED. 1. CONTRACTOR SHALL COVER DUCT OPENINGS AND PROTECT MECHANICAL EQUIPMENT FROM DUST AND DEBRIS GENERATED DURING CONSTRUCTION. FROM ROUGH INSTALLATION THROUGH FINAL RESTART OF ANY HVAC SYSTEM, ALL DUCT AND AIR DISTRIBUTION OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER ACCEPTABLE METHODS. 2. LIGHTING CONTROLS: PROVIDE MANUFACTURER'S CUT SHEETS AND SHOP DRAWING DOCUMENTATION HIGHLIGHTING ALL LIGHTING CONTROLS SYSTEMS COMPONENTS. 3. CARPETING SYSTEMS TO MEET CARPET & RUG INSTITUTE (CRI) GREEN LABEL PLUS PROGRAM, INCLUDING CARPET PAD, WHERE SCHEDULED. SUBMITTALS FOR ALL CARPET MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING THAT ALL CARPET SYSTEMS MEET OR EXCEED THE TESTING AND PRODUCT REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PLUS PROGRAM. 4. SUBMITTALS FOR ALL RESILIENT FLOOR COVERING MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING CERTIFICATION UNDER EITHER THE GREENGUARD FOR CHILDREN & SCHOOLS OR FLOORSCORE INDOOR EMISSIONS TESTING PROGRAM. 5. SUBMITTALS FOR ALL ENGINEERED WOOD FLOORING AND BAMBOO FLOORING MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING CERTIFICATION UNDER EITHER THE GREENGUARD OR FLOORSCORE INDOOR EMISSIONS TESTING PROGRAM. 6. ALL COMPOSITE WOOD AND OR SUBSTRATES AND ASSEMBLIES, INCLUDING PLYWOOD,PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD INSTALLED ON THE INTERIOR OR EXTERIOR OF THE PROJECT MUST COMPLY WITH THE FORMALDEHYDE REQUIREMENTS OF THE ARB's AIR CONTROL TOXIC MEASURES FOR COMPOSITE WOOD. THESE PRODUCTS MAY BE STAMPED WITH "CALIFORNIA 93120 COMPLIANT FOR FORMALDEHYDE" OR "CALIFORNIA PHASE 2 COMPLIANT" OR OTHER' 7. SUBMITTALS FOR ALL COMPOSITE WOOD AND AGRIFIBER PRODUCTS (INCLUDING BUT NOT LIMITED TO PARTICLEBOARD, WHEATBOARD, STRAWBOARD, AGRIBOARD PRODUCTS, ENGINEERED WOOD COMPONENTS, SOLID-CORE WOOD DOORS, OSB, MDF, AND PLYWOOD PRODUCTS) MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING THAT THESE PRODUCTS CONTAIN NO UREA FORMALDEHYDE RESINS. 8. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT ALL GYPSUM WALLBOARD PRODUCTS ARE MOISTURE AND MOLD-RESISTANT. 9. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT FIBERGLASS BATT INSULATION CONTAINS NO ADDED UREA-FORMALDEHYDE. 10. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT MECHANICAL SOUND INSULATION MATERIALS IN AIR DISTRIBUTION DUCTS CONSISTS OF AN IMPERVIOUS, NON-POROUS COATINGS THAT PREVENT DUST FROM ACCUMULATING IN THE INSULATING MATERIALS. 11. MERCURY IN LIGHTING: PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA FOR FLUORESCENT OR HID LAMPS HIGHLIGHTING MERCURY CONTENT. 12. FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 120.1 OF THE CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6 AND CHAPTER 4 OF CCR, TITLE 8 OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. 13. FOR BUILDINGS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF THE LATEST EDITION OF THE CALIFORNIA ENERGY CODE, SECTION 120.1(C)(4). 14. EMPLOY BUILDING ASSEMBLIES AND COMPONENTS WITH STC VALUES DETERMINED IN ACCORDANCE WITH ASTM E 90 AND ASTM E 413. 1. LIGHTING CONTROLS: PROVIDE MANUFACTURER'S CUT SHEETS AND SHOP DRAWING DOCUMENTATION HIGHLIGHTING ALL LIGHTING CONTROLS SYSTEMS COMPONENTS. 2. CARPETING SYSTEMS TO MEET CARPET & RUG INSTITUTE (CRI) GREEN LABEL PLUS PROGRAM AND 2019 CGBSC 5.504.4.4., INCLUDING CARPET PAD, WHERE SCHEDULED. SUBMITTALS FOR ALL CARPET MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING THAT ALL CARPET SYSTEMS MEET OR EXCEED THE TESTING AND PRODUCT REQUIREMENTS OF THE CARPET AND RUG INSTITUTE GREEN LABEL PLUS PROGRAM. 3. RESILIENT FLOORING SYSTEMS SHALL COMPLY WITH 5.504.4.6. SUBMITTALS FOR ALL RESILIENT FLOORCOVERING MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING CERTIFICATION UNDER EITHER THE GREENGUARD FOR CHILDREN & SCHOOLS OR FLOORSCORE INDOOR EMISSIONS TESTING PROGRAM. 4. SUBMITTALS FOR ALL ENGINEERED WOOD FLOORING AND BAMBOO FLOORING MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING CERTIFICATION UNDER EITHER THE GREENGUARD OR FLOORSCORE INDOOR EMISSIONS TESTING PROGRAM. 5. ALL COMPOSITE WOOD AND OR SUBSTRATES AND ASSEMBLIES, INCLUDING PLYWOOD,PARTICLEBOARD AND MEDIUM DENSITY FIBERBOARD INSTALLED ON THE INTERIOR OR EXTERIOR OF THE PROJECT MUST COMPLY WITH THE FORMALDEHYDE REQUIREMENTS OF THE ARB's AIR CONTROL TOXIC MEASURES FOR COMPOSITE WOOD AND TABLE 5.504.4. THESE PRODUCTS MAY BE STAMPED WITH "CALIFORNIA 93120 COMPLIANT FOR FORMALDEHYDE" OR "CALIFORNIA PHASE 2 COMPLIANT" OR OTHER. 6. SUBMITTALS FOR ALL COMPOSITE WOOD AND AGRIFIBER PRODUCTS (INCLUDING BUT NOT LIMITED TO PARTICLEBOARD, WHEATBOARD, STRAWBOARD, AGRIBOARD PRODUCTS, ENGINEERED WOOD COMPONENTS, SOLID-CORE WOOD DOORS, OSB, MDF, AND PLYWOOD PRODUCTS) MUST INCLUDE MANUFACTURER'S PRODUCT DATA VERIFYING THAT THESE PRODUCTS CONTAIN NO UREA FORMALDEHYDE RESINS. 7. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT ALL GYPSUM WALLBOARD PRODUCTS ARE MOISTURE AND MOLD-RESISTANT. 8. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT FIBERGLASS BATT INSULATION CONTAINS NO ADDED UREA-FORMALDEHYDE. 9. PROVIDE MANUFACTURER'S CUT SHEETS OR PRODUCT DATA VERIFYING THAT MECHANICAL SOUND INSULATION MATERIALS IN AIR DISTRIBUTION DUCTS CONSISTS OF AN IMPERVIOUS, NON-POROUS COATINGS THAT PREVENT DUST FROM ACCUMULATING IN THE INSULATING MATERIALS. 10. ADDITION AND ALTERATION TO A BUILDING OR TENANT SPACE THAT MEET THE SCOPING PROVISION IN SECTION 301.3 FOR NONRESIDENTIAL ADDITIONS AND ALTERATIONS, SHALL REQUIRE VERIFICATION THAT UNIVERSAL WASTE ITEMS SUCH AS OTHER CALIFORNIA PROHIBITED UNIVERSAL WASTE MATERIALS ARE DISPOSED OF PROPERLY AND ARE DIVERTED FROM LANDFILLS. A LIST OF PROHIBITED UNIVERSAL WASTE MATERIAL SHALL BE INCLUDED IN THE CONSTRUCTION DOCUMENTS. 1. NEW FIXTURES SHALL NOT EXCEED THE MAXIMUM FLOW RATES: • LAVATORY FAUCETS 0.5 gmp@60 psi • METERING FAUCETS 0.20 GALLONS PER CYCLE / 20 [RIM SPACE (INCHES) AT 60 psi • WATER CLOSETS 1.28 GALLONS/FLUSH • WALL-MOUNTED URINALS 0.125 GALLONS/FLUSH • FLOOR-MOUNTED URINALS 0.5 GALLONS/FLUSH • SHOWERHEADS 1.8 GALLONS/FLUSH 2. CONTRACTOR TO INSTALL ALL APPROPRIATE WATER SAVING FIXTURES & EQUIPMENT. WHERE COMMISSIONING IS REQUIRED ENSURE THAT ANY SPECIALIZED EQUIPMENT THAT IS WITHIN THE SCOPE OF THE COMMISSIONING AGENT IS ACCOUNTED FOR DURING BUILDING COMMISSIONING. 3. CONTRACTOR OPERATION AND MAINTENANCE MANUAL MUST INCLUDE MANUFACTURER'S CUT SHEETS FOR ALL WATER- CONSUMING PLUMBING FIXTURES AND FITTINGS (TOILETS, URINALS, FAUCETS, SHOWERHEADS, ETC.) HIGHLIGHTING MAXIMUM FLOW RATES AND/OR FLUSH RATES. INCLUDE CUT SHEETS FOR ANY AUTOMATIC FAUCET-CONTROL DEVICES. 1. ENGAGE LOCAL JURISDICTION OR GOVERNING AGENCY FOR REGISTERED ENVIRONMENTAL TRANSPORTER TO HAUL 100% OF ALL C&D DEBRIS TO A SFDOE DEPARTMENT OF ENVIRONMENT REGISTERED FACILITY THAT CAN PROCESS AND DIVERT FROM LANDFILL A MINIMUM OF 65% OF MATERIAL GENERATED DURING THE PROJECT. 2. MAINTAIN MATERIAL HAULING MANIFESTS AND OTHER DOCUMENTATION TO VERIFY MATERIAL TYPE/ WEIGHT AND ACCEPTANCE OF MATERIALS BY RECYCLING CENTER. 3. SUBMIT ALL DEBRIS HANDLING DOCUMENTATION TO OWNER AT PROJECT CLOSE-OUT. 4. CONTRACTOR TO CONFIRM THAT ITEMS DESIGNATED FOR REUSE CAN BE REUSED, AND TAKE STEPS TO RETAIN THEM IN THE FINISHED WORK. 5. CONTRACTOR TO COORDINATE WITH PROJECT TEAM IN ESTABLISHING PROJECT GOALS FOR USING MATERIALS WITH 10% (OR 20%) RECYCLED CONTENT, AND IDENTIFY MATERIALS SUPPLIERS TO ACHIEVE THIS GOAL. DURING CONSTRUCTION, THE CONTRACTOR IS TO ENSURE THAT SPECIFIED RECYCLED CONTENT MATERIALS ARE PURCHASED & INSTALLED, USE THE CONSTRUCTION SUBMITTAL PROCESS TO CONFIRM COMPLIANCE, AND COORDINATE SUPPLIER & SUB-CONTRACTOR MATERIAL COSTS WITH THE RECYCLED CONTENT INDICATED ON THE SUBMITTALS. 6. CONTRACTOR TO DOCUMENT ALL RECYCLED CONTENT UTILIZED ON PROJECT. LIST MATERIAL, PERCENTAGE OF RECYCLED CONTENT (BY COST), SOURCE OF CONTENT (POST-CONSUMER/POSTINDUSTRIAL) AND MFG. DOCUMENTATION. 7. CONTRACTOR TO COORDINATE WITH PROJECT TEAM IN ESTABLISHING PROJECT GOALS FOR USING A MINIMUM OF 20% MATERIALS MANUFACTURED REGIONALLY (AND AN ADDITIONAL 10% MATERIALS EXTRACTED & MANUFACTURED REGIONALLY (WITHIN A RADIUS OF 500 MILES). DURING CONSTRUCTION, THE CONTRACTOR IS TO ENSURE THAT SPECIFIED MATERIALS ARE INSTALLED, AND QUANTIFY THE TOTAL PERCENTAGE OF LOCAL MATERIALS INSTALLED. (MR CREDIT 5.1 & 5.2) 8. PROCURE ALL CONSTRUCTION MATERIALS FROM EXTRACTOR/MANUFACTURERS LOCATED WITHIN 500 MILES OF CONSTRUCTION SITE, U.O.N. PROVIDE DOCUMENTATION TO OWNER OF ALL MATERIALS FROM EXTRACTOR/MANUFACTURERS BEYOND 500 MILES OF QUANTITY, COST AND PERCENTAGE OF NON-REGIONAL MATERIALS COMPARED TO ALL MATERIALS BY COST. 9. CONTRACTOR TO COORDINATE WITH PROJECT TEAM IN ESTABLISHING PROJECT GOALS FOR USE OF RAPIDLY RENEWABLE MATERIALS, AND TO IDENTIFY THE MATERIALS & SUPPLIERS TO ACHIEVE THIS GOAL. DURING CONSTRUCTION, THE CONTRACTOR IS TO ENSURE THAT SPECIFIED MATERIALS ARE INSTALLED, AND QUANTIFY THE TOTAL PERCENTAGE OF RAPIDLY RENEWABLE MATERIALS INSTALLED. (MR CREDIT 6) 10. RAPIDLY RENEWABLE PRODUCTS: SUBMITTALS MUST INCLUDE WRITTEN DOCUMENTATION FROM THE MANUFACTURER DECLARING THAT RAPIDLY RENEWABLE MATERIALS ARE MADE FROM PLANTS HARVESTED WITHIN A TEN-YEAR OR SHORTER CYCLE AND MUST INDICATE THE PERCENTAGE (BY WEIGHT) OF THESE RAPIDLY RENEWABLE COMPONENTS CONTAINED IN THECANDIDATE PRODUCTS, ALONG WITH THE COSTS OF EACH OF THESE MATERIALS, EXCLUDING LABOR AND DELIVERY COSTS. 11. CONTRACTOR TO COORDINATE WITH PROJECT TEAM IN ESTABLISHING PROJECT GOALS FOR USE OF AT LEAST 50% FSC- CERTIFIED WOOD, AND TO IDENTIFY THE SUPPLIERS TO ACHIEVE THIS GOAL. CONTRACTOR TO COMPILE & MAINTAIN COPIES OF VENDOR INVOICES FOR EACH PRODUCT USED TO MEET THIS REQUIREMENT. (MR CREDIT 7) 12. ALL WOOD AND WOOD PRODUCTS TO BE INCORPORATED MUST BE CERTIFIED BY THE FOREST STEWARDSHIP COUNCIL. PROVIDE COPIES OF CERTIFICATES TO OWNER UPON PROJECT COMPLETION. WHERE CERTIFIED WOULD IS NOT AVAILABLE PROVIDE DOCUMENTATION TO OWNER OF QUANTITY, COST AND PERCENTAGE OF NON-CERTIFIED WOOD COMPARED TO OVERALL WOOD PRODUCTS. 13. CERTIFIED WOOD: SUBMITTALS FOR ALL WOOD-BASED MATERIALS MUST INCLUDE A STATEMENT INDICATING THE COST OF EACH PRODUCT CONTAINING FSC CERTIFIED WOOD, EXCLUSIVE OF LABOR AND DELIVERY COSTS, AND THIRD PARTY VERIFICATION OF CERTIFICATION FROM ONE OF THE FOLLOWING: A. CERTIFICATES OF CHAIN-OF-CUSTODY FROM MANUFACTURERS CERTIFYING THAT SPECIFIED CERTIFIED WOOD PRODUCTS WERE MADE FROM WOOD OBTAINED FROM FORESTS CERTIFIED BY AN FSC-ACCREDITED CERTIFICATION BODY TO COMPLY WITH FSC 1.2 "PRINCIPLES AND CRITERIA." LETTER FROM APPROVED CANADIAN STANDARDS ASSOCIATION (CSA) SUPPLIER FOR VERIFYING COMPLIANCE WITH CSA STANDARD Z809-02 AND STANDARD CSA PLUS 1163. B. DOCUMENTATION FROM THE SUPPLIER VERIFYING THAT 100% OF THE WOOD-BASED CONTENT ORIGINATES FROM SFI THIRD-PARTY CERTIFIED FOREST LANDS, IDENTIFYING THE COMPANY OR COMPANIES THAT PERFORMED THE SFI THIRD- PARTY CERTIFICATION FOR BOTH THE FOREST LAND MANAGEMENT AND THE CERTIFIED PRODUCT CONTENT. 1. ALL ADHESIVES, SEALANTS AND CAULKS SHALL COMPLY WITH SCAQMD RULE 1168 VOC LIMITS AND CCR 17 FOR AEROSOL ADHESIVES. THIS INCLUDES ADHESIVES AND SEALANT PRIMERS. 2. ARCHITECTURAL PAINTS AND COATINGS SHALL COMPLY WITH VOC LIMITS OF THE ARB ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE. WHERE A SPECIALTY COATING DOES NOT APPLY, THE COATING SHALL BE CLASSIFIED AS A FLAT, NONFLAT, OR NONFLAT-HIGH GLOSS COATING AND THE VOC LIMIT FOR THAT COATING CATEGORY SHALL APPLY. 1. DEVELOP AND IMPLEMENT A PLAN OF PROCEDURES FOR TESTING AND ADJUSTING NEW SYSTEMS, INCLUDING (AS APPLICABLE): HVAC; INDOOR AND OUTDOOR LIGHTING AND CONTROLS; WATER HEATING; RENEWABLE ENERGY; LANDSCAPE IRRIGATION; AND WATER REUSE SYSTEMS. 2. BALANCE NEW HVAC SYSTEMS BEFORE OPERATION FOR NORMAL USE. 3. PROVIDE THE OWNER OR REPRESENTATIVE WITH A FINAL REPORT OF TESTING. 4. PROVIDE THE BUILDING REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF ALL GUARANTEES/WARRANTEES FOR EACH SYSTEM. 5. PROTECT ALL DUCT OPENINGS AND MECHANICAL EQUIPMENT DURING CONSTRUCTION. LIMIT USE OF PERMANENT HVAC DURING CONSTRUCTION TO CONDITIONING NECESSARY FOR MATERIAL AND EQUIPMENT INSTALLATION. IF PERMANENT HVAC IS USED DURING CONSTRUCTION, INSTALL MERV-8 FILTERS ON RETURNS, AND REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. (CALGREEN 5.504.5.3 THROUGH 5.504.5.3.1). 6. PROVIDE AT LEAST MERV-13 FILTERS IN REGULARLY OCCUPIED SPACES OF MECHANICALLY VENTILATED BUILDINGS. INSTALLED FILTERS MUST BE CLEARLY LABELED BY THE MANUFACTURER INDICATING THE MERV RATING, AND FILTER SPECIFICATION SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. (CALGREEN 5.504.5.3 THROUGH 5.504.5.3.1). 7. REDUCE USE OF POTABLE WATER FOR NEWLY INSTALLED FIXTURES AND FITTINS AS SUMMARIZED IN 2019 CGBSC SEC 5.303.3 INDOOR WATER USE FOR REFERENCE. 8. LIGHTING CONTROLS: PROVIDE MANUFACTURER'S CUT SHEETS AND SHOP DRAWING DOCUMENTATION HIGHLIGHTING ALL LIGHTING CONTROLS SYSTEMS COMPONENTS. E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m 1/8" = 1'-0" 4/ 3 0 / 2 0 2 1 6 : 2 5 : 0 1 P M A0.02 One Infinite Loop Cupertino, CA 95014 CALGREEN CHECKLIST AP21.01 Author IL01.1N FIXTURE TYPE MAXIMUM PERSCRIPTIVE FLOW RATE REFERENCE STANDARD (SEE CALIFORNIA PLUMBING CODE TABLE 1401.1) SHOWERHEADS 1.8 GPM @ 80 PSI N/A LAVATORY FAUCETS - NONRESIDENTIAL 0.5 @ 60 PSI ASME A112.18.1/CSAB125.1 KITCHEN FAUCETS 1.8 @ 60 PSI N/A WASH FOUNTAINS 1.8 [RIM SPACE (IN.)/20GPM @ 60 PSI] N/A METERING FAUCETS 0.20 GAL/CYCLES ASME A112.18.1/CSAB125.1 METERING FAUCETS FOR WASH FOUNTAINS 0.2 [RIM SPACE (IN.)/20GPM @ 60 PSI] N/A TANK-TYPE WATER CLOSETS 1.28 GAL./FLUSH AND EPA WATER SENSE CERTIFIED U.S. EPA WATERSENSE TANK-TYPE HIGH-EFFICIENCY TIOLET SPEC. FLUSHOMETER VALVE WATER CLOSETS 1.28 GAL./FLUSH ASME A112.19.2/CSA B45.15 - 2011 URINALS (WALL-MOUNTED) 0.125 GAL./FLUSH ASME A112.19.2/CSA B45.15 - 2011 X X X X X SEE 1, 7 / A0.2 X SEE 1, 7 / A0.2 X SEE 1-6, 5/ A0.2 X SEE 1-6, 5/ A0.2 X SEE 4/A0.2 X X X X X X X X X X X SEE 7 / A0.2 X SEE 7 / A0.2 X SEE 7 / A0.2 NO. DESCRIPTION: DATE: ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 Arnold Hom 06/23/21 DOOR #2 DOOR #2.1 DOOR #3.4 DOOR #3.3 DOOR #3 DOOR #3.1 DOOR #3.2 MO D ELNUMBERTRADENAMEPRODUCTMATERIAL F.E . MO D ELNUMBERTRADENAMEPRODUCTMATERIAL F.E . UP UP UP UP ITEMROOM_NUMBER ITEMROOM_NUMBER ITEMROO M_NUM BER ITEMROO M_NUM BER ITEMROO M_NUM BER M O D ELNUMBERTRADENAM E PRO D UCTM A TERIALM O D ELNUMBERTRADENAM E PRO D UCTM A TERIAL MO D ELNUMBERTRADENAMEPRODUCTMATERIAL F.E . MO D ELNUMBERTRADENAMEPRODUCTMATERIAL F.E . UP UP UP UP ITEMRO O M_N UM BER ITEMRO O M_N UM BER ITEMROO M_NUM BER ITEMROO M_NUM BER ITEMROO M_NUM BER M O D ELNUMBERTRADENAM E PRO D UCTM A TERIALM O D ELNUMBERTRADENAM E PRO D UCTM A TERIAL CR CR CR CR CR CR CR CR CR CR CR CR CR CR CR AREA OF WORK 61'-0" MAX. COMMON PATH OF TRAVEL 76'-6" MAX. COMMON PATH OF TRAVEL X1 4' - 6 1 / 2 " 6' - 8 " 5' - 0 " OFFICE A141 350 SF MDF A133 CORRIDOR 1 STOR. A143 RESTROOM A140 OFFICE A142 CORRIDOR 2 CORRIDOR 16 845 SF STAIR #1 CORRIDOR 15 EXIT PASSAGEWAY STAIR #1 FREIGHT ELEV. CORRIDOR 10 OFFICE A121 OFFICE A119 OFFICE A115 MOTHER'S A113 OFFICE A117 OFFICE A122 OFFICE A120 OFFICE A116 OFFICE A118 OFFICE A114 CONF. A123 CONF A111CORRIDOR 9 CORRIDOR 8 STOR. A134 STOR. A136 STOR. A138 STOR. A139 OFFICE D104 OFFICE D103 OFFICE D102 OFFICE D105 OFFICE D106 OFFICE D107 OFFICE D108 OFFICE D111 OFFICE D110 OFFICE D109 CORRIDOR 3 OFFICE D113 OFFICE D112 OFFICE D114 OFFICE D115 CORRIDOR 4 BREAK RM. D116 WOMEN'S D122 MEN'S D123 CORRIDOR 5 CORRIDOR 6 LAB D127 CONF. A112 STOR. D120 ELEC. A110 SECURITY RM. D117 SECURITY RM. D137 STOR. D129 OFFICE D136 OFFICE D135 CORRIDOR STAIR #2 CORRIDOR 17 SEATING AREA SEATING AREA CONF. P117 BREAK RM. P113 OFFICE STOR. BREAK RM. P111 CORRIDOR 18 CONF. P115 CONF. P119 CONF. P119A CORRIDOR 19 OFFICE P131 OFFICE P133 OFFICE P135 CONF. P134 CORRIDOR 20 OFFICE P132 CORRIDOR 21 OFFICE P124 CONF. P125 SEC. RM. N121 COMMS. RM. N119 ELEC. N115 SEC. RM. P122 STOR. P120 UTILITY P118 PRINT/COPY N113 STOR. N113A STOR. P116 STAIR #3 OPEN OFFICE CORRIDOR 22 OFFICE R111 OFFICE R115 OFFICE R117 OFFICE R119 OFFICE R121 CORRIDOR 26 STOR. T101 RESTROOM T104 RESTROOM T103JAN. T102 RETAIL T100 CORRIDOR 25 OFFICE R114 OFFICE R116 OFFICE P161 CONF. OFFICE P162 CONF. OFFICE P160 OFFICE S104 STAIR #G4 OFFICE P158 WOMEN'S N116 MEN'S N114 CORRIDOR 24 JAN. S122 ELEC. S120 UTILITY S124 STAIR #4 ELEC. T109 CORRIDOR 23 IDF T108 STOR. T105 OFFICE T107 OFFICE T106 BREAK RM. OFFICE N109B OFFICE N109C OFFICE N109OFFICE N109A CONF. N108 CORRIDOR 28 LOADING DOCK 1 /3 MA X . DI AG. = 71' - 4" 213' - 11 1 /2" MAX. D I A G . > 7 1' - 4 " ( 1 / 3 M A X . DI A G . ) 1 2 0 ' - 4 " E X I T S E P A R A T I O N 1/3 MA X. D I AG. = 40'-4 1 /2" 12 1 ' - 1 1 / 2" MA X . DIAG. > 40'-4 1/2 " ( 1 /3 M A X. D I A G . ) 85' - 1 1 1 /2" EX I T S E P A RA T I O N > 64 ' -0 1 /4" (1/3 M A X . D I A G .) 136 ' - 2 1/ 2" E XI T S E P A R A TI O N 1 / 3 M A X . DI A G . = 6 4 '- 0 1 / 4 " 1 9 2 ' - 2 1 / 4 " M A X . D I A G . X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X1 X X2 X X EXIT #1 384 OCC. LOAD x 0.15" = 57.6" REQ'D WIDTH < 68" MIN. PROVIDED -OK PER CBC 2019 1005.5.3.2. EXIT #7.1 44 OCC. LOAD x 0.15" = 6.6" REQ'D WIDTH < 68" MIN. PROVIDED -OK PER CBC 2019 1005.5.3.2. 3 216 (FROM 4TH FLOOR)162(FROM GARAGE) 6 384 (FROM CORRIDOR 16) 14 44 37 7 266 238 19 189 446 736 EXIT #3, #3.1, #3.2 736 OCC. LOAD x 0.15" = 110.4" REQ'D WIDTH < 160" MIN. (40" + 80" + 40") PROVIDED -OK PER CBC 2019 1005.5.3.2. A8.00 1 1 CEILING EXIT SIGN EGRESS PATH COMMON PATH OF TRAVEL TACTILE EXIT SIGN, SEE DETAIL 4/- FEC FIRE EXTINGUISHER CABINET SEPARATE AREA FROM (E) BLDG. ROOM NAME XXX SF RM # LOAD OCC ROOM NAME AREA OCCUPANCY LOAD FACTOR OCCUPANCY ROOM NUMBER 100 EXIT DISCHARGECL E A R 18 " M I N . CLEAR 18" MIN. CL 45 ° 18"x18" CLEAR SPACE CENTERED ON TACTILE CHARACTERS 5'-0" MAX. (A.F.F.) 4'-0" MIN. (A.F.F.) BE L O W R A I S E D L E T T E R , T Y P . 3/ 8 " T O 1 / 2 " ( M A X . ) TO 2 " M A X . 5/ 8 " M I N . CHARACTER TO BE RAISED 1/32". UPPER CASE. SAN SERIF TYPE. RAISED CHARACTER HEIGHT TO BE MIN. 5/8" AND MAX. 2". COLOR (TO MATCH EXISTING) CONTRACTED GRADE 2 BRAILLE WITH MATCHING TEXT: DOTS TO BE 1/10" O.C. IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND. CONTRASTING BACKGROUND COLOR (GRAY) PLEASE NOTE THAT SIGNAGE SHALL READ AS FOLLOWS: "EXIT" AT THE ACTUAL EXIT DOOR "EXIT ROUTE" AT EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT VIA AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY."EXIT ROUTE" AT EACH EXIT DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO HAVE A VISUAL EXIT SIGN. "EXIT STAIR DOWN". "EXIT STAIR UP" AT EXIT STAIRS LEADING DOWN OR UP RESPECTIVELY "TO EXIT" AT HORIZONTAL EXIT DOORX X1 X1 X2 X4 SIGN SURFACE TO HAVE A NON-GLARE SURFACE AT VISIBLE SIDE. LOCATE SIGN ON WALL ADJACENT TO LATCH SIDE OF DOOR, OUTSIDE OF ROOM. A CLEAR FLOOR SPACE OF 18"x18" (MIN.) CENTERED ON THE TACTILE CHARACTER IS PROVIDED. (PER 2019 CBC SECTION 11B-703.4.2). SEE DETAIL SIGNS WITH CHARACTER AND BRAILLE SHALL BE LOCATED AT 48" A.F.F. (MIN.) MEASURED FROM BASELINE OF THE LOWEST BRAILLE CELLS & 60" A.F.F. (MAX.) MEASURED FROM BASELINE OF THE HIGHEST LINE OF RAISED CHARACTER, PER 2019 CBC SECTION 11B-703.4 INSTALLATION HEIGHT AND LOCATION / 3 A0.50 1. VERIFY QUANTITY AND LOCATION OF EXIT SIGNS, RELOCATE AND PROVIDE NEW AS NECESSARY AS INDICATED ON PLAN. 2. EXIT SIGNS MUST BE LOCATED SO THAT THE NEAREST ONE IS WITHIN 100 FEET OF THE SIGNS LISTING VIEWING DISTANCE. 3. ADDITIONAL EXIT SIGNS AND OR EMERGENCY LIGHTING MAY BE REQUIRED BASED ON FIELD INSPECTIONS. OCCUPANCY LOAD CALCULATION GROUP AREA NET/GROSS OCCUPANT LOAD TOTAL FACTOR OCCUPANCY ACCESSORY EQUIP, ELECTRICAL, 6,342 SF NET 300 SF 36 JAN CLOSET, TELECOM & STORAGE 1:300 ACCESSORY-HALLS, TOILETS,2,582 SF NET 0 SF 0 RISERS, SHAFTS & STAIRS 1:0 BUSINESS / ASSEMBLY A3 1:15 4,200 SF NET 15 SF 280 BUSINESS / ASSEMBLY B 1:15 5,289 SF NET 15 SF 355 RETAIL M 1:60 2,528 SF NET 60 SF 42 BUSINESS AREA UNCONENTRATED 26,882 SF GROSS 150 SF 179 1:150 TOTAL: 47,823 SF 892 *GROSS AREA INCLUDES ALL INTERIOR AREAS NOT INCLUDED IN NET SQUARE FOOTAGE CALCULATIONS. COMMON PATH OF EGRESS TRAVEL ALLOWED (PER TABLE 1006.2.1) GROUP A, M -(FULLY SPRINKLERED) = 75'-0" GROUP B -(FULLY SPRINKLERED) = 100'-0" EXIT ACCESS TRAVEL DISTANCE ALLOWED (PER 2019 CBC TABLE 1017.2) GROUP A, M -(FULLY SPRINKLERED) = 250'-0" GROUP B -(FULLY SPRINKLERED) = 300'-0" E T HI ESE ICL N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 6/ 4 / 2 0 2 1 1 1 : 5 8 : 1 4 A M A0.50 One Infinite Loop Cupertino, CA 95014 LIFE SAFETY PLAN AP21.01 Author IL01.1N 1/16" = 1'-0" 2LIFE SAFETY PLAN LEGEND -LIFE SAFETY 1/2" = 1'-0" 3TACTILE EXIT SIGN LOCATION 12" = 1'-0" 4 TACTILE EXIT SIGN GENERAL NOTES -LIFE SAFETY EXIT WIDTH CALCULATION NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT 2021.04.30 1 PLAN CHECK RESP. 1 2021.06.04 Arnold Hom 06/23/21 18 E D.9 D.8 D.7 D.5 D.3 1.1 1.1 1.1 A1.10 9 OFFICE A141 OFFICE B115 OFFICE B110 D C 1.5 1.6 EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE 1. CONTRACTOR SHALL VERIFY EXISTING FIELD CONDITIONS PRIOR TO DEMOLITION. 2. PATCH AND REPAIR ALL WALLS, FLOORS AND CEILINGS DAMAGED DURING DEMOLITION. 3. CONTRACTOR SHALL PROTECT EXISTING EXTERIOR FACADE AND STOREFRONT, U.O.N. 4. PRIOR TO DEMOLITION, CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER OR TENANT AND ARCHITECT TO IDENTIFY ITEMS (QUANTITY AND QUALITY) TO BE SAFELY STORED FOR RE-USE. 5. ALL ELECTRICAL AND DATA OUTLETS, SWITCHES OR THERMOSTATS THAT CONFLICT WITH THE NEW LAYOUT SHALL BE TAKEN BACK TO SOURCE AND REMOVED. 6. REMOVE DOORS, FRAMES AND HARDWARE AS INDICATED ON PLAN. SAVE FOR REUSE. 7. EXISTING ELECTRICAL PANELS AND LOW VOLTAGE PANELS SHALL REMAIN, U.O.N. 8. REMOVE ALL (E) UNUSED OR ABANDONED CABLING AS REQUIRED BY 2019 CALIFORNIA ELECTRICAL CODE. 9. ALL DEMOLITION WASTE SHALL BE TRANSPORTED BY REGISTERED HAULER TO A REGISTERED FACILITY AND BE PROCESSED FOR RECYCLING IN COMPLIANCE WITH LOCAL JURISDICTION'S CONSTRUCTION & DEMOLITION DEBRIS ORDINANCE. 10. EXISTING FIRE EXTINGUISHERS SHALL REMAIN, U.O.N. 11. CARPET TILE THAT IS REMOVED AND NOT SALVAGED FOR REUSE TO BE RECYCLED BY CARPET MANFACTURER. INCLUDE RECYLCING COST IN PROJECT BASE BID AS LINE ITEM. 18 D.7 D.5 D.3 OFFICE A141 OFFICE B115 OFFICE B110 D C 1.7 EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE EXISTING CEILING GRID AND TILE TO BE DEMOLISHED 18 (E) WALL MOUNTED UPLIGHT DEMO PARTIAL (E) PARTITION. PREP FOR NEW GLAZING 4' - 4 " DEMO (E) DOOR E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 4/ 3 0 / 2 0 2 1 6 : 2 5 : 0 5 P M A1.10 One Infinite Loop Cupertino, CA 95014 DEMOLITION PLAN & RCP AP21.01 Author IL01.1N 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"1DEMOLITION PLAN LEGEND -DEMO PLAN KEYNOTES 1.1 REMOVE (E) CARPET AND PREP. FOR NEW FLOOR FINISH. SEE FINISH PLAN. 1.5 DEMO PORTION OF (E) 2-HOUR RATED EXIT PASSAGE FOR NEW WALL OPENING. PREPARE NEW RATED DOOR OPENING. SEE DOOR SCHED. 1.6 WORK MUST OCCUR SO AS NOT TO DISRUPT EGRESS THROUGH EXIT PASSAGE DURING BUSINESS HOURS. 1.7 REMOVE AND RELOCATE EXIT SIGN, SEE RCP FOR NEW LOCATION. GENERAL NOTES 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0" 3 DEMOLITION RCP LEGEND -DEMO RCP 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"9HALLWAY ELEV. -DEMO NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 CR (E) CR DB ALIGN 18 E D.9 D.8 D.7 D.5 D.3 3 A6.10 5 OFFICE A141 2.06 2.06 2.06 (E ) A 1 4 1 D C CORRIDOR B114 STAIR G1 EXIT PASSAGEWAY B1 1 4 . 1 PARTITION (EXISTING) PARTITION (NEW) SINGLE LEAF DOOR DOOR IDENTIFICATION NUMBER DOUBLE LEAF DOOR DOOR IDENTIFICATION NUMBER XX X X XX X X CARD READER ALIGN PARTITION TYPE -SEE PARTITION TAG LEGEND AND PARTITION DETAILS A101 SIM. 1 1 1 1 ELEVATION SYMBOLMILLWORK A1A DOOR BELL AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE FEC FIRE EXTINGUISHER CABINET 1. CONTRACTOR SHALL VERIFY EXISTING FIELD CONDITIONS PRIOR TO DEMOLITION. 2. DIMENSIONS NOTED "CLEAR" OR "CLR" ARE FOR EQUIPMENT OR ACCESSIBILITY CLEARANCES AND MUST BE MAINTAINED. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 3. DIMENSIONS NOTED "VERIFY" OR "VIF" SHALL BE CHECKED BY CONTRACTOR PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 4. CONTRACTORS SHALL NOT SCALE DRAWINGS. ALL DIMENSIONS ON DRAWINGS TAKE PRECEDENCE OVER SCALE. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 5. PROVIDE LAYOUT MARKINGS OF PARTITIONS ALONG WITH ASSOCIATED IN-WALL ELECTRICAL DEVICES ON THE SUBFLOOR FOR REVIEW BY PROJECT TEAM ON SITE PRIOR TO PROCEEDING WITH PARTITION FRAMING. VERIFY ALL FURNITURE-RELATED ELECTRICAL LAYOUT WITH FURNITURE VENDOR. 6. ALL HEIGHTS ARE DIMENSIONED FROM TOP OF EXISTING SLAB UNLESS NOTED "A.F.F." (ABOVE FINISHED FLOOR). 7. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL SQUARE AND TRUE AND IN PROPER ALIGNMENT. 8. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. THE CONTRACTOR SHALL PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHEREVER REQUIRED. 9. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. 10. ACOUSTICALLY INSULATED WALLS, ALL GYPSUM BOARD PERIMETERS, VERTICAL JOINTS, CUTOUTS, OUTLETS AND OTHER PENETRATIONS, SHALL BE COMPLETELY CAULKED WITH NON- HARDENING, PERMANENT, RESILIENT ACOUSTICAL SEALANT. 11. DIMENSIONS ARE FROM FACE OF FINISH TO FACE OF FINISH (U.O.N.) 12. CONTRACTOR SHALL LEAVE THE PREMISES AND ALL AFFECTED AREAS IN A CLEAN AND AN ORDERLY MANNER READY FOR MOVE IN. 13. NEW SECURITY SYSTEM AND CARD READER HARDWARE TO BE COORDINATED WITH SECURITY VENDOR, HARDWARE/DOOR SUBCONTRACTOR, GENERAL CONTRACTOR AND TENANT. NO CARD READER PLANNED AT THIS TIME. 14. WHERE DAMAGED DURING DEMOLITION, CONTRACTOR SHALL REPAIR DAMAGED SPRAY-ON FIREPROOFING AT METAL DECK, BEAMS AND COLUMNS. THICKNESS SHALL BE DETERMINED PER MANUFACTURERS SPECIFICATIONS TO MATCH RATING OF EXISTING ADJACENT FIREPROOFING. CONTRACTOR SHALL ARRANGE FOR SPECIAL INSPECTION AS REQUIRED BY GOVERNING AUTHORITIES. 15. ALL THROUGH-PENETRATIONS OF NEW OR EXISTING FIRE AND SMOKE-RATED WALL AND FLOOR ASSEMBLIES SHALL BE PROTECTED TO MEET THE REQUIREMENTS OF 2019 CBC. CHAPTER 7. PROVIDE U.L.-APPROVED THROUGH-PENETRATION FIRESTOP SYSTEMS AROUND ALL PENETRATIONS TO MATCH THE ADJACENT WALL RATING. ALL CABLE PENETRATIONS SHALL BE SLEEVED AND CAULKED AS REQUIRED FOR U.L. LISTING. PROVIDE SMOKE AND FIRE DAMPERS AT ALL DUCT PENETRATIONS IN RATED FLOOR OR WALL ASSEMBLIES IN ACCORDANCE WITH 2019 CBC SECTIONS 717.2 INSTALLATION AND 717.5 WHERE REQUIRED. 18 E D.9 D.8 D.7 D.5 D.3 OFFICE A141 F1 F1 F1 F1F1F1 F1 F1 F1 9' -7" D C 819 SF CORRIDOR B114 EXIT PASSAGEWAY B116 STAIR G1 B115 EXISTING CONSTRUCTION TO REMAIN GYPSUM BOARD CEILING 2x2 ACOUSTIC CEILING TILE 24x24 ARMSTRONG ULTIMA BEVELED TEGULAR CEILING TILE IN (E) CEILING GRID AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE FINELITE HPR 2X2 LIGHT FIXTURE F1 CEILING EXIT SIGN 1. ALL DIMENSIONS ARE TO CENTERLINE OF OUTLET OR GROUP OF OUTLETS. OUTLETS NOT SPECIFICALLY DIMENSIONED SHALL BE LOCATED WITHIN 12" OF THE LOCATION INDICATED ON THE PLAN. DIMENSIONS BETWEEN PAIRED DEVICES SHALL BE 6" ON CENTER, U.O.N. ALL NEW OUTLETS SHALL BE LOCATED TO THE NEAREST STUD, U.O.N. 2. ALL NEW OR RELOCATED DOWNLIGHTS, WALLWASHERS, SPRINKLER HEADS, EXIT SIGNS, SPEAKERS, ETC. SHALL BE LOCATED IN THE CENTER OF THE CEILING TILES, U.O.N. 3. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. (E) CEILING HEIGHT TO REMAIN, U.O.N. 4. CONTRACTOR SHALL VERIFY SEISMIC BRACING OF EXISTING T-BAR AND LIGHT FIXTURES. PROVIDE BRACING, SEE DETAILS D3.0 IF REQUIRED. 5. CONTRACTOR SHALL COORDINATE AND MODIFY EXISTING LIGHT FIXTURE SWITCH LOCATIONS WITH NEW PARTITION LAYOUT. 6. REWORK HVAC, SPRINKLERS AND THERMOSTATS, AS REQUIRED, TO COORDINATE WITH NEW PARTITION LAYOUT. 7. ALL NEW SWITCHES AND THERMOSTATS SHALL BE MOUNTED NOT MORE THAN 48" A.F.F., MEASURED FROM TOP OF OUTLET (PER 2019 CBC SECTION 11B-308.1.1.) THERMOSTAT LOCATION PLAN SHALL SUBMITTED TO TENANT FOR APPROVAL PRIOR TO INSTALLATION. 8. ALL SWITCHES SHALL BE IN MULTIPLE GANG BOXES. COVERPLATE COLOR SHALL BE WHITE. REPLACE EXISTING SWITCHES WITH NEW. 9. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 10. ELECTRICAL TO BE DESIGN/BUILD. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CIRCUITING AND TITLE 24 CALCULATIONS. 11. ELECTRICAL CONTRACTOR SHALL ENSURE THAT LIGHTING CONTROLS COMPLY WITH BUILDING AUTOMATION CONTROLLER AND SHUT OFF SUCH THAT THEY MEET REQUIREMENTS SET FORTH IN TITLE 24 SECTION 131 A,B, AND C. 12. ALL ACOUSTICAL CEILINGS SHALL COMPLY WITH 2019 CBC SECTION 803 AND 808. PER CGBSC 2019 SECTION A5.504. 13. HVAC TO PROVIDE SOUND CONTROL RETURN AIR AND TRANSFER BOOTS ON ALL ENCLOSED ROOMS TO MINIMIZE NOISE TRANSFER BETWEEN ENCLOSED SPACES & ENCLOSED OPEN SPACES. E T HI ESE IC L N L A T T E S C AFO IANOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 4/ 3 0 / 2 0 2 1 6 : 2 5 : 0 7 P M A2.10 One Infinite Loop Cupertino, CA 95014 PARTITION PLAN & RCP AP21.01 Author IL01.1N 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"1PARTITION PLAN LEGEND KEYNOTES 2.06 INFILL PARTITION TO MATCH EXISTING. GENERAL NOTES -PARTITION PLAN 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"3 REFLECTED CEILING PLAN LEGEND GENERAL NOTES -RCP NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 CDA PD SN DATA CR CR (E) DATA RECEPTACLE -PROVIDE MUD RING AND PULL STRING DEDICATED RECEPTACLE, FINISH MOUNTED U.O.N. DUPLEX RECEPTACLE, FLUSH MOUNTED U.O.N. QUAD RECEPTACLE, FLUSH MOUNTED OVERHEAD COMPRESSED DRY AIR OVERHEAD POWER DROP OVERHEAD SNORKEL POWER BASE FEED: 2 CIRCUITS | 2 DATA OVERHEAD DATA DROPINDICATES OUTLET IS 24" A.F.F. MEASURED O.C. @24" CARD READER AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE 1. (E) ELECTRICAL, TELEPHONE AND DATA OUTLETS TO REMAIN (U.O.N.) CONTRACTOR TO VERIFY ALL (E) OUTLETS. (E) OUTLETS ARE NOT SHOWN ON PLAN. 2. OUTLETS INDICATED ON PLAN ARE NEW PER TENANT REQUIREMENTS. PROVIDE NEW ONLY IF OUTLETS DO NOT EXIST AND ARE NOT IN CLOSE PROXIMITY. REUSE WIRING WHEN NEW OUTLET LOCATION IS IN CLOSE PROXIMITY TO EXISTING OUTLET, AND PROVIDE NEW DEVICE AND COVERPLATE AS REQUIRED. 3. ALL NEW OUTLETS SHALL BE NO LESS THAN 15" MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX AND NOT MORE THAN 48" MEASURED FROM THE TOP OF RECEPTACLE OUTLET BOX. PER CBC 2019 SECTION 11B-308.1.2 4. EXISTING ELECTRICAL PANELS TO REMAIN, U.O.N. 5. ALL WIRING AT ELECTRICAL AND TELEPHONE/DATA OUTLETS THAT ARE ABANDONED SHALL BE TAKEN BACK TO SOURCE AND REMOVED. PROVIDE BLANK COVERPLATES AS REQUIRED. 6. NEW COVERPLATE STYLE AND COLOR FOR ALL OUTLETS SHALL MATCH EXISTING. 7. ALL ELECTRICAL OUTLETS, EXISTING OR NEW, SHALL RECEIVE GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION PER 2019 CEC SECTION 210.8. INCLUDING ALL OUTLETS IN BATHROOMS, KITCHENS AND WITHIN 6' OF BREAK ROOM OR UTILITY AREA SINKS. 8. PROVIDE COVERPLATES (BLANKS OR OUTLETS) WHERE MISSING, TO MATCH EXISTING. 9. ALL CABLING IN THE RETURN AIR PLENUM SHALL BE PLENUM RATED OR TEFLON COATED AS REQUIRED. 10. OUTLETS NOT SPECIFICALLY DIMENSIONED SHALL BE LOCATED WITHIN 12" OF THE LOCATION INDICATED ON PLAN. DIMENSIONS BETWEEN PAIRED DEVICES SHALL BE 6" O.C. 11. ALL OUTLETS SHOWN BACK-TO-BACK SHALL BE OFFSET THE MINIMUM DIMENSION REQUIRED TO AVOID BACK-TO-BACK INSTALLATION. SEE DETAIL D1.0 FOR OUTLET MOUNTING HEIGHTS. COORDINATE OUTLET LOCATIONS WITH ALL CASEWORK AND OTHER WALL-MOUNTED EQUIPMENT. 12. PER 2019 CBC CHAPTER 11B-403.5.2, WHERE ACCESSIBLE ROUTE MAKES A 180 DEGREE TURN AROUND AN ELEMENT WHICH IS LESS THAN 48 INCHES WIDE, CLEAR WIDTH SHALL BE 42 INCHES MIN. APPROACHING THE TURN, 48 INCHES MIN. AT THE TURN AND 42 INCHES MIN. LEAVING THE TURN. 13. ALL CONDUIT SHALL BE LOCATED IN PARTITION OR ABOVE CEILING EXCEPT AT STEEL COLUMNS OR EXPOSED CONCRETE WALLS, AND SHALL NOT BE EXPOSED, U.O.N. 1. PATCH, REPAIR, REPAINT WALL, REPLACE FLOORING & BASE WHERE DAMAGED DURING CONSTRUCTION. PROVIDE CP-1 FLOOR FINISH, B-1 BASE AND P-1 PAINT IN ALL LABS U.O.N. 2. PAINT: • TWO COATS LATEX EGGSHELL FINISH WITH ONE COAT OF PRIMER. • FOLLOW GREEN SEAL STANDARD GS-11 FOR TOPCOAT PAINTS, GS-03 FOR ANTI-CORROSIVE PAINTS AND SCAQMD RULE #1113 FOR ALL OTHER PRIMERS, UNDERCOATS AND ARCHITECTURAL COATINGS. INTERIOR PAINT SHALL MEET THE REQUIREMENTS OUTLINED IN LEED EB V2.0 GUIDELINES. SEE CREDIT MR CREDIT 3.1 AND 3.2 FOR ADDITIONAL INFORMATION. DUNN EDWARDS SPARTAWALL LOW ODOR ZERO VOC INTERIOR EGGSHELL PAINT SWLL30. 3. ALL NEW BASE SHALL BE B-1, U.O.N. 4. PROVIDE FINISH SAMPLES AND BRUSHOUTS TO ARCHITECT FOR REVIEW PRIOR TO APPLICATION. 5. PAINT EXISTING INTERIOR WALLS AND DOOR WITHIN AREA OF WORK AS SHOWN. 6. ALL ADHESIVES, SEALANTS AND CAULKS SHALL COMPLY WITH VOC LIMITS IN SCAQMD RULE 1168 VOC LIMITS, AS SHOWN IN TABLE 5.504.4.1 ADHESIVE VOC LIMIT AND 5.504.4.2. SEALANT VOC LIMIT, PER 2019 CGBSC, SECTION 5.504.4.1. 7. ALL PAINTS AND COATING SHALL COMPLY WITH VOC LIMITS IN THE AIR RESOURCES BOARD ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE PER 2019 CGBSC SECTION 5.504.4.3 VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS. 8. CARPET INSTALLED IN THE BUILDING INTERIOR SHALL MEET THE TESTING AND PRODUCT REQUIREMENT PER CALIFORNIA GREEN BUILDING STANDARD CODE 2019, SECTION 5.504.4.4. 9. RESILIENT FLOORING SHALL COMPLY WITH VOC-EMISSION LIMITS DEFINED IN 2009 CHPS CRITERIA, PER 2019 CALIFORNIA GREEN BUILDING STANDARD CODE SECTION 5.504.4.6. 10. VERIFY THAT FLOOR SUB-SURFACE IS SMOOTH, LEVEL, AND FREE FROM DEFECTS THAT WOULD AFFECT THE INSTALLATION. DO NOT PROCEED WITH WORK UNTIL DEFECTS HAVE BEEN CORRECTED., THOROUGHLY CLEAN SUB-FLOOR PRIOR TO INSTALLATION OF THE FINISH FLOOR AND PREPARE PER MANUFACTURERS'S RECOMMENDATIONS FOR A SMOOTH, CONSISTENT FLOOR FINISH. 11. MODULAR CARPET TILE.RESILIENT FLOORING TO LAY SYMMETRICALLY ABOUT CENTERLINES OF SPACES WITH EITHER JOINT OR CENTERLINE OCCURRING IN CENTER. CUTTING OF FIELD TILES IS NOT PERMITTED. ALIGN EXACTLY PARALLEL TO RESPECTIVE WALLS NEATLY. TRIM MATERIAL ABUTTING OTHER WORK TO FORM TRUE CLEAN JOINTS. PATTERN SHALL RUN IN ONE DIRECTION ONLY, U.O.N. CLEAN AND SEAL RESILIENT FLOORING AT END OF PROJECT PER MANUFACTURER'S RECOMMENDATIONS. 12. ALL FLOOR TRANSITIONS SHALL MEET ACCESSIBILITY REQUIREMENTS PER 2019 CBC SECTION 11B-404.2.5 AND FIGURE 11B-302. 13. PARTITION FINISH NOTES: • GYP. BD. AT VISIBLE SURFACES LEVEL 4 FINISH U.O.N. 14. GYP. BD. AT SPECIAL FINISH: LEVEL 5 FINISH SPECIFIC PAINT PRODUCT IS TO BE SUITABLE FOR SUBSTRATE SHALL BE PAINTED. PROVIDE MINIMUM ONE PRIME COAT/TWO FINISH COATS AT ALL SURFACES. ADD FINISH COATS IF REQUIRED FOR PROPER COVERAGE. 15. PROTECT ALL NEW OR EXISTING FINISHES FROM DAMAGE DURING CONSTRUCTION. PROTECT ALL SURFACES NOT TO BE PAINTED FROM OVERSPRAY AND SPATTER. REMOVE PAINT FROM SURFACES WHERE IT DOES NOT BELONG. DO NOT PAINT ELECTRICAL PANELS. 16. THE GENERAL CONTRACTOR AND ELECTRICIAN ARE TO TAKE SPECIAL CARE TO NOT LOCATE DEVICES ON SURFACES TO RECEIVE SPECIAL FINISHES SUCH AS ACCENT PAINT, MARKER BOARD, FABRIC-WRAPPED PANELS, ETC. SUBMIT ELECTRICAL AND LIFE-SAFETY DRAWINGS SHOWING DEVICE LOCATIONS FOR REVIEW BY ARCHITECT PRIOR TO ROUGH-IN OF THESE DEVICES. • DEVICE COVERPLATE COLORS: • ELECTRICAL/TELEDATA DEVICES: • WALLS -WHITE • FLOORS -COLOR TO MATCH ADJACENT FINISH FLOORING • LIFE-SAFETY: • WALLS -WHITE (NOT RED) • CEILINGS -WHITE (NOT RED) 17. LAY ALL RESILIENT AND SIMILR HARD-SURFACE FLOORING WITH GRAIN RUNNING IN A SINGLE DIRECTION (U.O.N.). FOR CARPET TILE, REVIEW DIRECTION REQUIREMENTS WITH ARCHITECT IF NOT ALREADY SPECIFIED IN THE DRAWINGS. FOR BROADLOOM CARPET INSTALLATION (IF OCCURS ON PROJECT), SUBMIT SEAMING DIAGRAMS IN ADDITION TO PRODUCT SAMPLES AND CUT SHEET INFORMATION FOR REVIEW BY ARCHITECT. 18. THE GENERAL CONTRACTOR SHALL VERIFY WITH THE OWNER THEIR REQUIREMENTS FOR ADDITIONAL MATERIALS INCLUDING FLOOR, WALL AND CEILING MATERIALS. COORDINATE DESIRED STORAGE LOCATIONS WITH OWNER. 19. VERIFY WORKING ORDER OF EXISTING WINDOW COVERINGS, REPAIR OR REPLACE ALL INOPERABLE OR DAMAGED UNITS. 20. ALL INTERIOR WALL & CEILING FINISH MATERIALS SHALL COMPLY WITH 2019 CBC SECTIONS 803 WALL AND CEILING FINISHES AND TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FOR FLAME SPREAD. 21. ALL INTERIOR WALL & CEILING FINISH MATERIALS SHALL HAVE A SMOKE DEVELOPMENT BETWEEN 0 AND 450 PER 2019 CBC SECTION 803.1.1 INTERIOR WALL AND CEILING FINISH MATERIALS. FLOOR TRANSITION X # FINISH TYPE FINISH NUMBER AREA NOT IN CONTRACT. PROTECT ALL FINISHES AND FIXTURES FROM DAMAGE START TILE FINISH START TILE ALIGN GUIDEALIGN FINISH DIRECTION 1 P 1 B ITEM: GENERAL PAINT MFR: SHERWIN WILLIAMS COLOR: SNOW WHITE FINISH: EGGSHELL ITEM: RUBBER BASE MFR: VPI/600 COLOR: 67 POLARIS SIZE: 2 1/2" H, CONTINUOUS ROLL CLASS: B 1 C ITEM: CARPET TILE MFR: MILLIKEN -TO BE VERIFIED STYLE: FORMWORK COLOR: FWK13 PILLAR SIZE: 50CMX50CM NOTE: MONOLITHIC LAYOUT CONSISTENT THROUGHOUT WALL FINISH:FLOOR FINISH: 18 E D.9 D.8 D.7 D.5 D.3 OFFICE A141 1 C 1 P 1 P D C 18 E D.9 D.8 D.7 D.5 D.3 OFFICE A141 5.25.2 D C E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. NE W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 4/ 3 0 / 2 0 2 1 6 : 2 5 : 0 8 P M A4.10 One Infinite Loop Cupertino, CA 95014 POWER, DATA & FINISH PLAN AP21.01 Author IL01.1N LEGEND KEYNOTES 5.2 REUSE EXISTING WHITEBOARD FOR NEW OFFICE. GENERAL NOTES -ELECTRICALGENERAL NOTES -FINISH PLAN LEGEND FINISH SCHEDULE 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"3 FINISH PLAN 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"1POWER AND DATA PLAN NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 (E) SLAB ON DECK 9/64" X 1" LONG POWDER ACTUATED FASTENERS COMPRESSION POST, FOR POST LAYOUT SEE DETAILS 2 / - 5/8". 1 1 / 2 " . 1 1/2 ". (B) BRACING WIRE (A) HANGING WIRE HILTI X-U (.157") W/MIN 1" EMBEDMENT STRUCTURE 12 GA. STEEL STRAP 1-1/2" WIDE X 2" LONG 4 TIGHT TURNS SPLAYED SEISMIC BRACING WIRE HILTI CC 27ZF27 P&T CEILING CLIP AND POWDER DRIVEN PIN (OR APPROVED EQUAL) STRUCTURE 3 TIGHT TURNS VERTICAL HANGING WIRE COMPRESSION POST SECURED TO STRUCTURE ABOVE. SEE DETAILS 5/- 1" DIA. STANDARD PIPE COMPRESSION POST VERTICAL WIRE SUPPORT, SEE DETAIL 6/- BRACING WIRE. SEE 6/- CROSS MEMBER MAIN MEMBER LAY IN ACOUSTICAL TILE. SEE PLAN FOR LAYOUT, SIZE AND TYPE. TYP. 4'-0" TY P . 2' - 0 " TYP. 8". TY P . 6" . 4'-0" MAX. TO FIRST BRACE WALL LINE FIRST BRACING POINT FROM WALL COMP. POST ON 12' x 12' GRID 4-WAY, 45 DEG. DIAG. 12 GA WIRE BRACING ON 12' x 12' GRID 12 GA. VERTICAL HANGER WIRES AT 4'-0" O.C. EA. WAY SECONDARY RUNNER WALL LINE 18 A6.10 15 A6.10 17 A6.10 19 A6.10 8" MAX. 7/8". SCHEDULED PARTITION WALL ANGLE MOLDING, COLOR TO MATCH GRID VERTICAL WIRE, SEE DETAIL 1/- 1-1/4" TYPE -S PAN HEAD SCREWS AT 12" O.C. MIN. 3 TIGHT TURNS IN 1-1/2" AT VERT. HANGER WIRE ARMSTRONG SEISMIC RX SUSPENSION SYSTEM, ICC-ESR-1308 ACOUSTIC CEILING ARMSTRONG BERC-2 CUP ATTACHMENT TO EACH TEE FOR MOVEMENT, INSTALL PER MFR. SPECIFICATION. SCREW TIGHTENED THROUGH RUNNER WEB RESTRICTING SEPARATION FROM WALL MOLDING WHERE ANGLE MOLDING CHANGES DIRECTION & THE PARTITION CONTINUES IN A STRAIGHT LINE, ADD A STRIP OF MOLDING FROM THE CHANGE IN DIRECTION, IN LINE W/ THE WALL, TO THE NEAREST CEILING GRID BEYOND. ARMSTRONG BERC-2 CLIP SYSTEM IS COMPLIANT WITH ASCE 7-05 SECTION 13.5.6.22. LIGHT FIXTURE, SEE REFLECTED CEILING PLAN AND ELECTRICAL DRAWINGS ONE 12 GA. WIRE AT TWO (2) OPPOSITE CORNERS OF EACH FIXTURE WITH FOUR TIGHT TURNS 12 GA. WIRE HANGERS AT 45 DEG. AT EACH CORNER LAY IN CEILING TILE T-BAR FRAMING. ATTACH FIXTURE TO MAIN RUNNER WITH ONE NO. 8 SCREW AT TWO OPPOSITE CORNERS DIFFUSER OR LOUVER TO MATCH EXISTING 8" MAX. CLR. 3/4" 7/8". SCHEDULED PARTITION WALL ANGLE MOLDING, COLOR TO MATCH GRID VERTICAL WIRE, SEE DETAIL 1/- 1-1/4" TYPE -S PAN HEAD SCREWS AT 12" O.C. MIN. 3 TIGHT TURNS IN 1-1/2" AT VERT. HANGER WIRE ARMSTRONG SEISMIC RX SUSPENSION SYSTEM, ICC-ESR-1308 ACOUSTICAL CEILING ARMSTRONG BERC-2 CLIP ATTACHMENT TO EACH TEE FOR MOVEMENT, INSTALL PER MFR. SPECIFICATION. SCREW NOT TIGHTENED THROUGH RUNNER TO PROVIDE EXPANSION MOVEMENT FROM WALL MOLDING WHERE ANGLE MOLDING CHANGES DIRECTION & THE PARTITION CONTINUES IN A STRAIGHT LINE, ADD A STRIP OF MOLDING FROM THE CHANGE IN DIRECTION, IN LINE W/ THE WALL, TO THE NEAREST CEILING GRID BEYOND ARMSTRONG BERC-2 CLIP SYSTEM IS COMPLIANT WITH ASCE 7-05 SECTION 13.5.6.22. 18 4' - 4 " (E) WALL SCONCE (E) CARD READER APPLY 3M DUSTED CRYSTAL FILM TO GLASS, TYP. PAINT WINDOW FRAMES TO MATCH (E) DOOR FRAME 9 A6.10 EXISTING PARTITION ALIGN W/ (E) SOFFIT WINDOW/GLAZING ASSEMBLY PER 2019 CBC 24-2403.2.1 3/8" CLEAR TEMPERED GLASS (E) PARTITION HOLLOW METAL FRAME 16 GA. x 2" WIDE STRAPS, 1 @ FLOOR LINE & 24" O.C. (2@ HEAD OVER 3'-0") ATTACH TO FRAMING W/ (2) #8 PAN HEAD S.M.S. SCHEDULED DOOR SEE DOOR SCHEDULE 2" 1 / 2 " - 1 / 2 " . 2" (E) PARTITION HOLLOW METAL FRAME 16 GA. x 2" WIDE STRAPS, 1 @ FLOOR LINE & 24" O.C. (2 @ HEAD OVER 3'-0") ATTACH TO FRAMING W/ (2) #8 PAN HEAD S.M.S. SOLID CORE WOOD DOOR (SEE DOOR SCHECHDULE) 1. ALL NEW AND EXISTING LATCH/LOCKSET SHALL BE LEVER TYPE. ALL HARDWARE TO FUNCTION PROPERLY. CONTRACTOR SHALL ADJUST AS REQUIRED. HARDWARE MOUNTING HEIGHT TO COMPLY WITH CBC AND ADA REQUIREMENTS. 2. HARDWARE SHALL BE CENTERED BETWEEN 34" MIN. AND 44" MAX. A.F.F. 3. THE MAXIMUM FORCE REQUIRED TO OPERATE DOORS PER 2019 CBC SECTION 11B-404.2.9 DOOR AND GATE OPENING FORCE SHALL BE AS FOLLOWS: INTERIOR DOORS: 5 POUNDS SLIDING OR FOLDING DOORS: 5 POUNDS RATED DOORS: 15 POUNDS EXTERIOR DOORS: 5 POUNDS 4. THE REQUIRED PULL SIDE STRIKE EDGE DISTANCE PROVIDED FOR INTERIOR DOORS VARIES AND SHALL COMPLY WITH 2019 CBC TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES AND FIGURE 11B-404.2.4.1 AND MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOOR OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS TABLE 11B-404.2.4.2. MANEUVERING CLEARANCES AT MANUAL SWING DOORS AND GATES. 5. MOUNT ALL CLOSERS ON THE NON-PUBLIC SIDE OF DOORS, TYP. (U.O.N.) 6. ALL RATED DOORS TO HAVE SMOKE GASKETS AND CLOSERS. ALL ASSEMBLIES SHALL BE "S" LABELED BY APPROVED TESTING AGENCY. 7. INSTALL HINGE JAMB OF DOORS 4" FROM ADJACENT WALL (U.O.N.) 8. ALL DOORS DESIGNATED TO BE FIRE RATED SHALL BE LABELED AS REQUIRED BY CODE. PROVIDE FIRE RATED FRAME SIZED TO SPECIFIC FIRE RATED PARTITION. 9. COORDINATE ALL LOCKING, LATCHING AND KEYING REQUIREMENTS FOR THE BUILDING USE AND SECURITY WITH BUILDING REPRESENTATIVE AND NEW TENANT PRIOR TO PURCHASE AND INSTALLATION OF HARDWARE. 10. FURNISH 4 1/2 x 4 1/2 HINGES AT ALL NEW DOORS AND FRAMES. U.O.N 11. ALL DOOR WITHIN 10 INCHES OF THE FINISH FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE PER CBC 11B-404.2.10. 12. THRESHOLD AT ALL DOORS SHALL NOT EXCEED 1/2" ABOVE THE FINISHED FLOOR OR LANDING. RAISED THRESHOLDS AMD FLOOR LEVEL CHANGES GREATER THAN 1/4" AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50% SLOPE), PER 2019 CBC 1010.1.6 13. HARDWARE AT ALL RATED DOORS AND ASSEMBLIES SHALL BE LISTED AND UL LABELED PER REQUIRED RATING(S). 14. AT ALL RATED DOORS, PROVIDE SMOKE SEALS (PEMKO S88D). AT RATED DOOR PAIRS, PROVIDE AN ASTRAGAL (PEMKO 355AV, CLEAR FINISH). 15. ALL INTERIOR DOOR DIMENSION TO MATCH EXISTING, U.O.N., 1-3/4" THICK SOLID CORE. FINISH TO MATCH EXISTING. 16. UNDERCUT ALL DOORS TO PROVIDE 3/8" MIN. AND 5/8" MAX. CLEARANCE ABOVE FINISH FLOOR THROUGHOUT SWING OF DOOR. 17. COORDINATE FRAME TRIM INSULATION WITH CARPET INSTALLATION. FRAME TRIM SHALL BE SET OVER CARPET TO PREVENT NEED FOR TRIMMING CARPET. 18. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. 19. G.C. TO VERIFY ALL PROPOSED HARDWARE FOR EXISTING REUSED DOORS FUNCTIONS PROPERLY. 20. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED, UNLESS ANY OF THE EXCEPTIONS TO 2019 CBC SECTION 1010.1.9.5 BOLT LOCKS ARE MET. 21. EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, THUMB TURN, OR ANY SPECIAL KNOWLEDGE OR EFFORT PER 2019 CBC SECTION 1010.1.9. DOOR OPERATIONS. 22. ALL DOORS WITH CARD READERS ARE SPECIFIED TO SECURE DOORS ON THE NON- EGRESS SIDE OF DOORS ONLY, PER 2019 CBC 1010.1.9. THIS PROJECT DOES NOT INCLUDE MAGLOCK DOORS OR EGRESS DOORS WITH SENSOR RELEASED LOCKS. DOORS PROVIDED WITH SENSORS TO RELEASE ELECTRICALLY LOCKED EGRESS DOORS SHALL BE INSTALLED PER 2019 CBC SECTION 1010.1.9.9 SENSOR RELEASE OF ELECTRICALLY LOCKED EGRESS DOORS. 23. DOORS SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR, SEMI-GLOSS FINISH. 11 / - 10/- SIM TYPE 1 HARDWARE GROUP DESCRIPTION MODEL FINISH (626/US26D Satin Chrome U.O.N.) MANUFACTURER HW-1 RATED FIRE RATED -SINGLE DOOR 4 HINGES 1 EXIT LOCK WITH CYLINDER 1 12" KICKPLATE 1 CLOSER 1 DOME STOP SMOKE SEALS BB1279 L9026 - 4040 241F S88 626 626 US32D BLK 626 BLK HAGER SCHLAGE - LCN HAGER PMK E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 4/ 3 0 / 2 0 2 1 6 : 2 5 : 1 1 P M A6.10 One Infinite Loop Cupertino, CA 95014 INTERIOR ELEVATION, DOOR SCHEDULE & DETAILS AP21.01 Author IL01.1N 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"14 COMPR. POST ATTACHMENT -CONC 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"13 WIRE ATTACHMENT @ CONC. DECK 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"15 COMPRESSION MEMBER 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"16T-BAR CEILING FRAMING 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"17 FIXED T-BAR CEILING JOINT 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"19 FIXTURE AT CEILING 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"18 FLOATING T-BAR CEILING JOINT 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"5HALLWAY ELEV. 2" 8" 0" 1"1/2" 2"4"0" 1/4" 1" 3" = 1'-0"9 WINDOW HEAD/SILL 3" = 1'-0"11DR -H.M. DOOR HEAD 3" = 1'-0"10DR -H.M. DOOR JAMB GENERAL NOTES -DOORS DOOR TYPES Door Schedule NEW Door Room Width Height Material Finish Frame Material Frame Fin. Header Jamb Hardware Group Comments YES B114.1 EXIT PASSAGEWAY 3' - 0" 8' - 0" PG CLR HM CLR 11/- 10/-1 90-MINUTES FIRE RATED DOOR DOOR HARDWARE SCHEDULE NO. DESCRIPTION: DATE: PROGRESS SET 2021.03.31 ISSUE FOR PERMIT ----.--.-- Arnold Hom 06/23/21 30"X48" CLR. 30"X48" CLR. 30"X48" CLR. 30"X48" CLR. 1617 F.7 F.5 F.7 F.5 F.7F.5 OPEN 16 F.7 F.5 F.7 F.5 OPEN 17 17 5' - 1"5' - 1" 25" 1 8 " 1 8 " MEN'S D123 WOMEN'S D121 C L R . ø 5' - 0 " C L R . ø 5' - 0 " C LR. ø 5' - 0" C L R . ø 5 ' - 0 " 9' - 3"9' - 3" 60 " M I N . 60 " M I N . 60" MIN. 60" MIN. 25" A8.0 10 18 A8.0 14 A8.0 5 SIM. A8.0 17 9 A8.0 13 A8.0 5 CLR. 44" MIN. CLR. 44" MIN. 2.07 2.07 2.08 1 1 1 1 1 60" MIN. CLR.60" MIN. CLR. 2.092.09 1 1 2.10 1 MOUNTED W.C. 56" @ WALL 36" MIN. MANEUVERING SPACE MOUNTED W.C. 56" @ WALL36" MIN. MANEUVERING SPACE 1 1 OP E R A B L E P A R T S 40 " M A X . T O OP E R A B L E P A R T S 40 " M A X . T O OP E R A B L E P A R T S 40 " M A X . T O 1 34 " M A X . B. O . M I R R O R 40 " M A X @ A. F . F . 1 7 " M A X . 18" A. F . F . 1 7 " - 1 9 " 36 " M A X . 33 " M I N . 12" MIN.24" MIN. 36" MIN. 9 A8.01 60" MIN. OP E R A B L E P A R T S 40 " M A X . T O 34 " M A X . OP E R A B L E P A R T S 40 " M A X . T O OP E R A B L E P A R T S 40 " M A X . T O OP E R A B L E P A R T S 40 " M A X T O 1 18" A. F . F . 1 7 " - 1 9 " 36 " M A X . 33 " M I N . 12" MIN. 24" MIN. 36" MIN. 34 " M A X . B. O . M I R R O R 40 " M A X . @ 9 A8.01 60" MIN. 34 " M A X . OP E R A B L E P A R T S 40 " M A X . T O 36 " M A X . 33 " M I N . 12" MIN.42" MIN. 54" MIN. 7"-9" 24" MIN. 1 9 " M I N . OP E R A B L E P A R T S 40 " M A X . T O 1. THESE DRAWINGS PROVIDED TO DEMONSTRATE ACCESSIBILITY COMPLIANCE. EXISTING RESTROOMS MEET 2019 CBC CHAPTER 11B REQUIREMENTS. E T HI ESE IC L N L A T T E S C AFO IANOR I F No. RDAC T C C-28588 REN. IADV L. N E W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 6/ 4 / 2 0 2 1 1 1 : 5 8 : 2 3 A M A8.00 One Infinite Loop Cupertino, CA 95014 ENLARGED RESTROOM PLAN & ELEVATIONS AP21.01 Author IL01.1N 0"1/2"2" 0' 1" 4'16' 4" 2'8' 1/4" = 1'-0"1RESTROOM AS-BUILT PLAN 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"18 MEN'S ELEVATION -SOUTH 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"10MEN'S ELEVATION -NORTH 1/4" = 1'-0"14 MEN'S ELEVATION -WEST 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"17 WOMEN'S ELEVATION -NORTH 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"9WOMEN'S ELEVATION -SOUTH 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0" 13 WOMEN'S ELEVATION -WEST 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"5 WOMEN'S ELEVATION -EAST GENERAL NOTES NO. DESCRIPTION: DATE: ISSUE FOR PERMIT 2021.04.30 1 PLAN CHECK RESP. 1 2021.06.04 KEYNOTES 2.07 (E) RESTROOM SIGNAGE TO REMAIN. SEE DETAIL 1/A8.01 FOR ACCESSIBLE COMPLIANCE. 2.08 (E) URINAL TO REMAIN. SEE DETAIL 6/A8.01 FOR ACCESSIBLE COMPLIANCE. 2.09 (E) LAVATORY TO REMAIN. SEE DETAIL 9/A8.01 FOR ACCESSIBLE COMPLIANCE. 2.10 (E) HIGH/LOW DRINKING FOUNTAIN TO REMAIN. SEE DETAIL 3,4/A8.01 FOR ACCESSIBLE COMPLIANCE. 1 Arnold Hom 06/23/21 REFER TO CBC SECTION 11B-703.2 FOR RAISED LETTER REQUIREMENTS AND 11B-703.3 FOR GRADE 2 BRAILLE AT LATCH SIDE OF DOOR. CENTERLINE AT 60" ABOVE FINISH FLOOR. TITLE 24 COMPLIANT SIGNAGE CENTERED ON DOOR AT 60" ABOVE FINISH FLOOR. 12" IN HEIGHT AND 1/4" THICK, PER 2019 CBC 11B-703.4 INSTALLATION HEIGHT AND LOCATION. CONDITION AT MEN'S RESTROOM SHOWN. CONDITION AT WOMEN'S RESTROOM SIMILAR, EXCEPT WITH CIRCULAR SYMBOL ON THE DOOR. NOTE: A. AT LEAST ONE SIGN SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY PER CBC 11B-703.7 PICTORIAL SYMBOL SIGNS SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF ANY PICTOGRAM, IF PROVIDED, SHALL BE A MINIMUM OF 6" IN HEIGHT, AND SHALL HAVE RAISED PROFILE. B. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED, CONTRASTING IN COLOR, AND HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10, AND RAISED 1/32" MIN., AND BE ACCOMPANIED BY BRAILLE. C. WHERE PERMANENT SIGNAGE IS PROVIDE FOR ROOMS AND SPACES, SIGNAGE AS DESCRIBED ABOVE SHALL ALSO BE PROVIDED ON THE STRIKE SIDE OF THE DOOR. D. SIGNAGE SHALL COMPLY WITH ALL REQUIREMENTS OF 2019 CBC SECTIONS 11B-703 SIGNS AND ADAAG SECTION 4.30. MEN 60 " M A X . A . F . F HT . O F T A C T I L E C H A R A C T E R S 48 " M I N . A . F . F . 60 " A . F . F . 1 CONTRASTING BACKGROUND COLOR (GRAY) CHARACTERS TO BE RAISED OR RECESSED 1/32" MINIMUM, SAN SERIF UPPER CASE CONTRAST COLOR CONTRACTED GRADE II BRAILLE WITH MATCHING TEXT: DOTS TO BE 1/10" O.C. IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A MINIMUM OF 1/40" ABOVE THE BACKGROUND. LOCATE SIGN ON WALL ADJACENT TO LATCH SIDE OF DOOR, OUTSIDE OF ROOM SUCH THAT A CLEAR FLOOR SPACE 18" MIN. x 18" MIN. CENTERED ON THE TACTILE CHARACTERS IN PROVIDED BEYOND ARC OF ANY DOOR SWING FROM CLOSED TO 45 DEGREES OPEN POSITION. SIGNS WITH CHARACTER AND BRAILLE SHALL BE LOCATED AT 48" A.F.F. (MIN.) AND 60" A.F.F. (MAX.) PER 2019 CBC SECTION 11B-703.4 INSTALLATION HEIGHT AND LOCATION NOTE: DESIGN SHOWN IS GENERIC. COMMERCIALLY AVAILABLE SIGNS MEETING SPECIFIC REQUIREMENTS INDICATED MAY BE ACCEPTABLE PENDING REVIEW BY ARCHITECT. FOR MOUNTING HEIGHT SEE DETAIL .HEIGHT OF LETTERING 5/8" (MIN.) T0 2" (MAX.) DOOR MOUNTED SIGNAGE WALL MOUNTED SIGNAGE (PER 2019 CBC 11B-703.4 INSTALLATION HEIGHT AND LOCATION) (FOR: MEN) (FOR: WOMEN) (PER 2019 CBC 11B-703.4 INSTALLATION HEIGHT AND LOCATION) CENTER OF SYMBOLS TO BE AT 5'-0" ABOVE FINISH FLOOR ON DOORS LEADING TO SANITARY FACILITIES. SIGNAGE TO BE 1/4" THICK, TYP. SYMBOL COLOR: GRAY, CONTRASTS W/ DOOR. MEN WOMEN MEN 1'-0" DI A M E T E R 1 ' - 0 " / 2 A8.01 1 CL 18 " M I N . 48" MIN. REQUIRED CLEAR SPACE PLAN VIEW SECTION TO B . O . R E F L E C T I N G S U R F A C E 40 " M A X . ( A . F . F . ) MAX. 6" MI N . C L R . 9" 27 " M I N . C L R . 29 " M I N . C L R . SPECIFIED MIRROR** SPECIFIED LEVER TYPE OR ELECTRONICALLY CONTROLLED MECHANISM FAUCET. SELF-CLOSING VALVE SHALL MAINTAIN A MINIMUM OF 10 SECOND OPEN FLOW WALL HUNG LAVATORY 2'-10" A.F.F. MAX. MIN. CLR. 8" INSULATED PIPE, PER 2019 CBC 11B-606.5 EXPOSED PIPES AND SURFACES HATCHED AREA DENOTES REQUIRED KNEE CLEARANCE NOTE: ** MIRROR HEIGHT MEASURED FROM FLOOR FINISH SURFACE TO BOTTOM OF REFLECTED SURFACE, PER 2019 CBC SECTION 11B-603.3 MIRRORS 30 " M I N . 17" MIN. - 25" MAX.1 . 18" - 19" 5" (MAX.) TO OF BUBBLER TO B U B B L E R 36 " M A X . MI N . 2' - 3 " MI N . 9" LEVER/PUSH BAR TO BE LOCATED 6" (MAX.) FROM FRONT EDGE TOE CLEARANCE 6" MAX. KNEE CLEARANCE 8" MIN. DEPTH 17" MIN. NOTE: WATER STREAM SHALL BE PARALLEL TO THE FRONT EDGE OF ACCESSIBLE FOUNTAIN AND STREAM SHALL BE MIN. 4" IN HEIGHT AND SHALL BE LOCATED 5" MIN. FROM THE FRONT OF THE UNIT. (2019 CBC 11B-602.6) FORCE TO ACTIVATE CONTROLS NOT TO EXCEED 5 LBF. 2019 CBC 11B-602 CL CL R . S P A C E 30 " ( M I N . ) VA R I E S CLEAR SPACE 48" (MIN.) 19" (MAX.) 18" (MIN.) "HI" FOUNTAIN OF CLEAR SPACE & DRINKING FOUNTAIN "LOW" FOUNTAIN NOTE: @ HI-LO DRINKING FOUNTAIN, CENTER OF 30"x48" CLEAR FLOOR SPACE ON "LOW" FOUNTAIN FIXTURE CLEAR FLOOR SPACE PER CBC 11B-602.2 ALCOVE INSTALLATION 6" MAX. 27 " M I N . 16" MIN. CLE AR 4 4 " MI N. CLEAR 1 6 " MI N . CLEAR 36 " M A X . 38 " M I N . 43 " M A X . 5" MAX. 18" MIN. 19" MAX. TO B U B B L E R TO B U B B L E R 1 MA X . 17 " 13 1/2" MIN. 9" M I N . C L R . 44 " M A X . MA X . 17 " SIDE VIEW FRONT VIEW CLEAR SPACE 30" MIN. CL E A R S P A C E 48 " M I N . 48 " 6" M A X . 24 " M A X . CLEAR SPACE 36" MIN. >2 4 " PLAN VIEW: CLEARANCE REQUIREMENTS PER 2019 CBC 11B-605 URINALS CL E A R S P A C E 48 " M I N . 6" M A X . 1 1/2" - 1 1/4" - 1 1/2" NOMINAL DIAMETER SCHEDULED PARTITION NOTE: PROVIDE BACKING AS REQUIRED TO SUPPORT A 250 POUND FORCE. E T HI ESE IC L N L A T T E S C AFO IA NOR I F No. RDAC T C C-28588 REN. IADV L. NE W TIHD Y 01-31-23 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m As indicated 6/ 4 / 2 0 2 1 1 1 : 5 8 : 2 4 A M A8.01 One Infinite Loop Cupertino, CA 95014 ACCESSIBLE RESTROOM DETAILS AP21.01 Author IL01.1N 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"2SIGNAGE AT RESTROOM DOOR 2" 16" 0" 1" 1/2" 4"8"0" 1/4" 2" 1 1/2" = 1'-0"1RESTROOM SIGNAGE 2" 2' 0" 1"1/2" 6"1'0" 1/4" 3" 1" = 1'-0"9 RR LAVATORY-COUNTER HUNG 2" 4' 0" 1"1/2" 1'2'0" 1/4" 6" 1/2" = 1'-0"3 DRINKING FOUNTAIN CLEARANCE 0"1/2"2" 0' 1" 4'2'8' 1/4" = 1'-0"4HIGH/LOW DRINKING FOUNTAIN NO. DESCRIPTION: DATE: 1 PLAN CHECK RESP. 1 2021.06.04 0'1/2" 1"2" 0'1.3' 2.6'5.3' 3/8" = 1'-0"6ACCESSIBLE URINAL STALL 12" = 1'-0" 5 GRAB BAR Arnold Hom 06/23/21 Arnold Hom 06/23/21 MSB SINGLE LINE DIAG. & LOAD CALC EXEMPTION NOTE SCOPE OF WORK RESCUE ASSISTANCE RESCUE ASSISTANCE SIGNAGE, SEE 2-E1.1C. RACS RAS RESCUE ASSISTANCE CALL STATION, SEE 2-E1.1C. RESCUE ASSISTANCE CONTROL PANEL, SEE 2-E1.1C.RACP SEE SHEET E1.1 FOR AREA/S OF WORK PROJECT KEY PLAN (NTS), AREA/S OF WORK GENERAL NOTES (AS APPLICABLE) 1. ALL WORK SHALL SHALL COMPLY WITH CA 2019 BUILDING CODE, CA 2019 ELECTRIC CODE, & CA 2019 ENERGY CODE. 2. ALL ELECTRICAL INSTALLATIONS SHALL COMPLY WITH ALL APPLICABLE PROJECT SPECIFICATIONS, VIF WITH THE GC. 3. ALL CONDUIT INSTALLATIONS SHALL BE CONCEALED, & MINIMUM SIZE TO BE 1/ 2" UNO. 4. CEILING IS A RETURN AIR PLENUM. ALL MATERIALS IN CEILING (PIPES, WIRING, FINISHES, ETC...) SHALL BE LISTED FOR PLENUM USE. 5. EC SHALL COORDINATE ALL WORK WITH ALL OTHER TRADES, AND BE FAMILIAR WITH ALL PROJECT DRAWINGS. 6. ANY APPLICABLE REQUIRED POWER SHUTDOWNS SHALL BE COORDINATED WITH THE GC IN ADVANCE OF THE SHUTDOWN. 7. ALL EQUIPMENT AND DEVICES SHALL BE PROPERLY IDENTIFIED AND LABELED. 8. UNO, ALL CONDUIT FEEDERS AND BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND SIZED PER CEC / NEC 250.122. 9. MOUNTING HEIGHTS OF ALL ELECTRICAL DEVICES SHALL BE AS REFLECTED BELOW DIMENSIONS ARE TO DEVICE CENTER, UNO. ALSO, REFER TO THE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. UN-MARKED DEVICES ARE 18" AFF, UNO. A. RECEPTACLES, VOICE / DATA / TV OUTLETS 18" B. OUTDOOR RECEPTACLES 24" C. TOGGLE SWITCHES 44" D. FA AUDIO VISUAL DEVICES 80" E. EXIT SIGN FIXTURES 90" F. THERMOSTAT JUNCTION BOX, SECURITY / NURSE CALL STATIONS 46" G. CLOCK AND PAGING SPEAKER OUTLETS 84" H. INDIVIDUAL DISCONNECT SWITCHES, STARTERS 60" I. GROUPED DISCONNECT SWITCHES, STARTERS >15" THROUGH <79" J. PANEL BOARD OVERCURRENT DEVICES >15" THROUGH <79" K. WALL AND CORRIDOR MOUNT LIGHT FIXTURES 80" 10. 20A, 120V BRANCH CIRCUIT (ASSUMING 80% LOADING) WIRING SHALL BE ADJUSTED FOR VOLTAGE DROP REQUIREMENTS PER THE FOLLOWING: A. UP TO 60' IN LENGTH = #12 AWG CU CONDUCTORS. B. 60' THROUGH 100' = #10 AWG CU CONDUCTORS. C. 100' THROUGH 170' = #8 AWG CU CONDUCTORS. D. 170' THROUGH 250' = #6 AWG CU CONDUCTORS. 11. ALL ELECTRICAL PANELS SHALL HAVE AN ACCURATE & TYPEWRITTEN PANEL CARD DIRECTORIES, & SHALL HAVE PHENOLIC PANEL IDENTIFICATION PLAQUE PER CEC / NEC 408.4A OF THE FACE OF THE PANEL . 12. EC SHALL MAINTAIN AT THE JOB SITE UP TO DATE "AS BUILT" DRAWINGS, AND SHALL BE TURNED OVER TO THE EC PROJECT MANAGER UPON PROJECT COMPLETION. 13. ALL ELECTRICAL SYSTEMS INSTALLED OUTDOORS SHALL BE AN APPROVED WEATHERPROOF TYPE INSTALLATION. 14. COORDINATE ALL DEVICE LOCATIONS WITH GC & ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATIONS. 15. COORDINATE DEVICE AND PLATE FINISH COLOR WITH ARCHITECTURAL DRAWINGS & PROJECT SPECIFICATIONS. 16. ALL ELECTRICAL EQUIPMENT BY THE EC & THE CUSTOMER TO BE LISTED & LABELED PER CEC / NEC 90.7 & 110.3. 17. ALL PANELBOARD/SWITCHBOARDS SHALL HAVE COPPER BUSSING & BOLT ON STYLE BREAKERS, UNO. SEE APPLICABLE ADDITIONAL NOTES ON POWER PLAN SHEETS. 18. ALL BREAKER AIC RATINGS SHALL MATCH THE CORRESPONDING PANEL / SWITCH BOARD AIC RATING. 19. ALL XFMRS SHALL COMPLY WITH CEC / NEC ARTICLE 450-21 VIA 155° OR HIGHER INSULATION RATING. 20. ALL DISCONNECT SWITCHES LOCATED ABOVE ACCESSIBLE CEILINGS SHALL COMPLY WITH CEC / NEC 404.8A, EX 2. 21. ALL FUSES & HEATERS FOR STARTERS & DISCONNECT SWITCHES SHALL BE SIZED PER EQUIPMENT NAMEPLATE, VIF. 22. ALL ELECTRICAL EQUIPMENT CLEARANCES SHALL COMPLY WITH CEC / NEC 110-26. 23. AS APPLICABLE, PERFORM VISUAL INSPECTION OF EXISTING SWITCHBOARDS & PANELBOARDS, & NOTIFY GC / CLIENT OF APPLICABLE VIOLATIONS &/OR HAZARDS. 24. REFER TO LIGHTING & POWER PLANS FOR ADDITIONAL NOTES, & SPECIFICATIONS. 25. IN BLDGS WITH MORE THAN ONE NOMINAL VOLTAGE, EACH UNGROUNDED SYSTEM CONDUCTOR TO BE IDENTIFIED PER PHASE & SYSTEM. MEANS OF IDENTIFICATION SHALL BE PERMANENTLY POSTED AT EACH BRANCH CIRCUIT PANELBOARD, PER CEC / NEC 210.4.D. PHASE COLOR CODING SHALL BE BROWN, ORANGE, YELLOW FOR 480Y/277V SYSTEMS & BLACK, RED, BLUE FOR 208Y/120V SYSTEMS. FOR ALL 240/120V, 3Ø, 4W DELTA SYSTEMS, EC TO PROVIDE ORANGE MARKING FOR HIGH LEG CONDUCTOR (SHOULD BE BØ, VIF) AT ALL PANELS PER CEC / NEC 110-15, 230-56, & 408.3. ALSO PROVIDE A PHENOLIC LABEL ON ALL APPLICABLE PANELS. LABEL SHALL READ "PNL **-240/120V,3Ø,4W DELTA". 26. EC SHALL VIF WITH UTILITY COMPANY REGARDING THAT NEW PROJECT LOADING ON UTILITY XFMR IS ACCEPTABLE. 27. ALL ELECTRICAL INSTALLATIONS SHALL COMPLY WITH ARC FLASH REQUIREMENTS PER NEC 110.16 & NFPA 70E-2018. 28. 100% RATED CBS SHALL COMPLY & BE LABELED PER CEC / NEC ARTICLE 90.7, 110.1, 110.2, & 110.3, & ANY ASSOCIATED FEEDERS SHALL COMPLY WITH 215.3 & 230.42. 29. THIS ELECTRICAL DESIGN IS A CONCEPTUAL DESIGN. EC TO VIF ALL INSTALLATION METHODS & REQUIREMENTS. 30. REFLECTED CONDUIT ROUTING PATHS ARE FOR REFERENCE ONLY, EC SHALL VIF ALL ROUTING. FIELD REVISIONS TO CONDUIT AND CONDUCTORS SHALL COMPLY WITH ALL APPLICABLE CODES. FIELD REVISIONS TO CONDUCTORS SHALL COMPLY WITH CEC / NEC ARTICLES, 110.14, 210.19, 215.2, 230.42, 240.3, 310.15-16. 31. ALL J-BOXES & WIREWAY SHALL BE SIZED & INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CEC / NEC ARTICLES. 32. ALL WIRING SYSTEMS LOCATED ABOVE ALL GRID CEILINGS SHALL COMPLY WITH CEC / NEC ARTICLE 300-11. 33. ALL J-BOXES LOCATED ABOVE ALL SHEET ROCK CEILINGS SHALL BE ACCESSIBLE. 34. COORDINATE ALL EQUIPMENT LOCATIONS & REQ'S WITH THE GC PRIOR TO HOOK UP. 35. ALL ELECTRICAL PANELS & EQUIPMENT SHALL HAVE A MINIMUM OF 1"x2" ID LABEL. 36. MIN OF 36" CLEARANCE SHALL BE MAINTAINED IN FRONT OF ALL ELECTRICAL PANELS. 37. ALL WALL & FLOOR CORES & PENETRATIONS TO BE PERFORMED IN A NEAT MANNER, & BE SEALED WITH AN APPROVED FIRE SEALANT, AS WELL AS ALL ONE HOUR WALL DEVICES. SEE DETAILS ON SHEET E1.2A. 38. EC SHALL MAINTAIN NEAT / SAFE WORK AREAS AT ALL TIMES. ALL WORK AREAS AND METHODS SHALL COMPLY WITH ALL OSHA, GC, ALL OTHER TRADES REQUIREMENTS AT ALL TIMES. TRASH & ITEMS NOT NEEDED FOR CONSTRUCTION SHALL BE REMOVED FROM SITE DAILY. ALL DEMOLISHED ELECTRICAL EQUIPMENT / MATERIAL SHALL BE REMOVED FROM THE JOBSITE & PLACED IN TRASH CONTAINERS, VIF WITH THE GC. 39. ALL CONDUCTORS IN PARALLEL SHALL BE OF THE SAME LENGTH, & COMPLY WITH CEC / NEC 310-4. 40. REFER TO ARCHITECTURAL DRAWINGS FOR ANY APPLICABLE DEVICE DIMENSIONING. 41. PER ADA SECTION 4.2, ALL WALL MOUNTED DEVICES THAT ARE ACCESSIBLE TO WHEEL CHAIR ACCESS SHALL COMPLY WITH THE FORWARD REACH REQ'S AS IS FOLLOWING. MAXIMUM HIGH FORWARD REACH = 48" AFF TO TOP, MAX LOW = 15" AFF TO BOTTOM. 42. PROVIDE ALL APPLICABLE &/OR REQUIRED DEMOLITION WORK FOR CONSTRUCTION OF THIS PROJECT. COORDINATE ALL REQUIREMENTS WITH THE GC. ALL REMOVED WIRING SYSTEMS SHALL BE REMOVED BACK TO THE CORRESPONDING ELECTRICAL PANEL. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DEMOLITION REQUIREMENTS. 43. EC SHALL COORDINATE ALL REQUIRED POWER SHUTDOWNS WITH THE GC WELL IN ADVANCE OF ANY SHUTDOWN. DISRUPTIONS OF THE POWER SYSTEM WITHOUT GC APPROVAL IS PROHIBITED. 44. ALL MOTOR & FEEDER TAPS SHALL COMPLY WITH CEC / NEC 430.28, 430.24 & 240.21. 45. ALL BACK TO BACK ELECTRICAL OUTLET BOXES INSTALLED IN ONE HOUR FIRE RATED ASSEMBLY TO BE SEPARATED HORIZONTALLY BY A MINIMUM OF 24" BETWEEN BOXES. 46. ALL ROOF PENETRATIONS SHALL COMPLY WITH DETAIL 5 / 6-E1.2 ON SHEET E1.2A. 47. ALL APPLICABLE ROOF CONDUIT INSTALLATION METHODS TO CONFORM TO EX BLDG. STANDARD METHODS, & TO COMPLY WITH ALL APPLICABLE ARTICLES OF CEC / NEC. 48. COORDINATE EQUIPMENT LOCATIONS & REQ'S WITH GC PRIOR TO INSTALLATIONS. 49. COORDINATE ALL MECHANICAL EQUIPMENT LOCATIONS & REQUIREMENTS WITH MC & MECHANICAL DRAWING PRIOR TO ALL ELECTRICAL INSTALLATIONS, AS APPLICABLE. 50. EC SHALL HAVE ALL UNDERGROUND UTILITIES & SYSTEMS LOCATED VIA USA OR AN APPROVED EQUAL PRIOR TO ALL ESCAVATION & / OR ANY AUGERING WORK. 51. APPLICABLE RECEPTACLES & LIGHTING FED VIA EM PANEL SHALL BE INSTALLED IN SEPARATE CONDUIT SYSTEMS APART FROM NORMAL POWER WIRING SYSTEMS, & SHALL BE IDENTIFIED AS SUCH, PER CEC / NEC 700.9. 52. EQUIPMENT HOOK UP & WIRING INSTALLATIONS TO COMPLY WITH CEC / NEC 400 & 422. 53. SERVER ROOMS THAT ARE CLASSIFIED & CONSTRUCTED AS AN INFORMATION TECH- NOLOGY EQUIPMENT ROOM ARE REQUIRED TO COMPLY WITH CEC / NEC 645. 54. REFER TO ARCH. DRAWINGS FOR ADDITIONAL POWER PLAN GENERAL & SHEET NOTES. 55. COORDINATE DOWN LIGHT ROUGH IN LOCATIONS WITH GC PRIOR TO INSTALLATION. 56. DOWN LIGHT FIXTURES LOCATED IN CEILING TILES TO BE CENTERED IN THE TILE, VIF. 57. ALL ELECTRICAL PANELS SHALL HAVE ARC FLASH WARNING LABELS PER NEC 110.16. 58. SEE DETAIL 3-E1.2 FOR APPLICABLE LIGHTING CONTROL PANEL WIRING REQ'S. 59. ALL SWITCHES SHALL BE LABELED TO INDICATE THE AREA SERVED BY THE SWITCH. 60. ALL LIGHT FIXTURE INSTALLATIONS TO COMPLY WITH IBC & CEC, & DETAIL 9-E1.2A. 61. SWITCH GROUPING WHERE VOLTAGE BETWEEN SWITCHES IS >300V, REQUIRE BARRIERS PER CEC / NEC 404.8B. 62. BRANCH CIRCUIT VOLTAGE LIMITATIONS SHALL COMPLY WITH CEC / NEC 210.0. 63. VIF ALL FIXTURE LOCATIONS WITH GC, & ALL OTHER TRADES PRIOR TO INSTALLATIONS 64. SEE ARCH DRAWINGS FOR ADDITIONAL CEILING PLAN GENERAL & SHEET NOTES. 65. IF SUSPENDED CEILING SYSTEM IS CLASSIFIED AS A RETURN AIR PLENUM CEILING, COMPLIANCE WITH CEC / NEC 300.22C IS REQUIRED FOR ALL ABOVE CEILING WIRING. 66. SEE SHEET E0.1 FOR INTERIOR & EXTERIOR LIGHT FIXTURE SCHEDULES, AS APPLICABLE. 67. EXIT & EM FIXTURE FIXTURE WIRING & INSTALLATIONS SHALL COMPLY WITH 2019 CEC 700.9 & 700.12, & 2019 CBC 1008, 2701, 2702 AS APPLICABLE. EM POWER SOURCE FOR EXIT & EM FIXTURES SHALL BE VIA STORAGE BATTERIES, UNIT EQUIPMENT, OR AN ON-SITE GENERATOR. EXIT & EM FIXTURES SHALL BE ILLUMINATED AT ALL TIMES. ILLUMINATION SHALL NOT BE LESS THAN 90 MIN IN THE EVENT OF PRIMARY POWER EXIT PLACEMENT TO COMPLY WITH CBC 1011.1. EM LIGHTING TO BE ARRANGED TO PROVIDE AN AVERAGE OF 1 FOOT CANDLE ALONG THE ENTIRE PATH OF EGRESS. 68. ALL ELECTRICALLY POWERED FURNITURE CUBICLE PARTITIONS SHALL COMPLY WITH CEC / NEC ARTICLE 605. 69. ALL MULTIWIRE BRANCH CIRCUITS SHALL COMPLY WITH CEC / NEC ARTICLE 210.4. 70. ALL ROOF CONDUIT INSTALLATIONS SHALL COMPLY WITH NEC ARTICLE 310.15.B.2.C. 71. ALL UG CONDUITS SHALL HAVE PROPERLY SIZED EQUIPMENT GROUND CONDUCTOR. 72. ALL SERIES RATED EQUIPMENT SHALL COMPLY WITH CEC / NEC 240.86 & 110.22. 73. ALL EQUIPMENT BACKBOARDS SHALL BE 3/4" FIRE RETARDANT TREATED PLYWOOD. 74. ALL RECESSED DOWN LIGHTS INSTALLED IN CONTACT WITH INSULATION MATERIALS SHALL BE IC RATED LIGHTING FIXTURES, & BE LISTED AS SUCH IN FIXTURE SCHEDULE 75. ALL RECESSED LIGHTING IN A ONE HOUR CEILING TO COMPLY WITH CBC 713. REFER TO DETAILS ON E1.2B AS APPLICABLE FOR FIRESTOP REQ'S FOR LIGHT FIXTURES. 76. ALL CONDUIT WALL & FLOOR PENETRATIONS SHALL BE FIRE PROOFED PER THE CORRESPONDING HILTI FIRE STOP DETAILS ON E1.2A & E1.2B, AS APPLICABLE. 77. PENETRATIONS TO THE MEMBRANE OF ALL FIRE PARTITIONS BY ELECTRICAL BOXES & DEVICES SHALL COMPLY WITH CBC 713. REFER ALSO TO FIRE STOP DETAIL ON E1.2A. 78. ALL DISCONNECT SWITCHES FOR HVAC HEAT PUMPS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE ROOM ACCESS POINT. 79. EM & OR EXIT LIGHTING FIXTURES WITH TEST BUTTONS SHALL HAVE TEST BUTTONS INSTALLED IN AN ACCESSIBLE LOCATION WITHOUT REMOVING ANY PART OF FIXTURE. 80. EM / NIGHT LIGHT FIXTURES SHALL BE WIRED SO AS TO REMAIN ON ALL THE TIME (24/7). APPLE IL01.N SOW (EX BLDG & EX TENANT, NEW BADGING OFFICE RENOVATIONS) - ONE INFINITE LOOP - CUPERTINO, CA 1. PROVIDE (2) 20A, 120V, CUBICLE FEEDS; (1) 20A, 120V, 4PLEX WALL RECEPTACLE; (1) DATA RING & STRING OUTLET; (1) CARD READER RING & STRING PROVISION IN ROOM A141...AS IS REFLECTED ON SHEET E2.1. COMPLIANCE WITH CA 2019 ENERGY CODE SECTION 130.5 FOR POWER IS NOT REQUIRED FOR THIS PROJECT PER CA 2019 ENERGY CODE SECTION 141.0.b.2.P. 2.REPLACE EXISTING LIGHTING WITH NEW LED GRID TROFFER LIGHTING IN ROOM A141; PROVIDE NEW ENERGY CODE COMPLIANT LIGHTING CONTROLS; RELOCATE ONE EXIT FIXTURE FROM EXISTING DOUBLE DOOR TO NEW CORRIDOR DOOR....AS IS REFLECTED ON SHEET E3.1. REFER TO SHEET E3.2 FOR CA 2019 ENERGY CODE SECTION 130.0 FOR LIGHTING COMPLIANCE FORMS. 3.POWER FOR ITEM 1 & 2 ABOVE TO BE PROCURED FROM EXISTING ELECTRICAL PANELS. NEW PANELS ARE NOT REQUIRED FOR THIS PROJECT. 4.ALL MECHANICAL & PLUMBING EQUIPMENT, & POWER FOR THE SAME, IS EXISTING TO REMAIN AS IS, & N.I.C.. 5.PROVIDE MISCELLANEOUS DEMOLITION WORK AS REQUIRED FOR CONSTRUCTION OF THIS PROJECT. VIF WITH GC & CUSTOMER. REFER TO ARCHITECTURAL DRAWINGS FOR DEMO SCOPE, AS APPLICABLE. ABBREVIATIONS 1P/2P/3P A/AMP AF AS A/C AC ACL AFF / AFG AIC AL ANN ATS AWG BJ BS/BLDG BR BRKR C C.U. CAB CATV / COAX CB CC CCC CCTV CEC/CBC CECHA ComEd COMP CONN CONV CR CT CU CUH D/D DC DISC.SW. DP DPDT DPST DWG E.C. EF EHD EL ELEC EM EMT EP EQ ER/EX EUH EWC / EWH F FA FB FC/FC FDC FLUOR FLR FP FS GEN GFI GEC / GRD GP GRS HID / HPS HP HPFF HV Hz IBC IC IG IMC INC JB K KO kVA kW / KWH LA LC LS LTG LV / LVC M MC MCB / MFS MCC MCM MERC MFR SINGLE POLE, TWO POLE, THREE POLE AMPERES (AMPS) AMPERE FUSE AMPERE SWITCH AIR CONDITIONER ALTERNATING CURRENT ACROSS THE LINE ABOVE FLOOR FINISH / ABOVE FINISH GRADE AMPERES INTERRUPTING CAPACITY ALUMINUM ANNUNCIATOR AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BONDING JUMPER BUILDING STEEL, BUILDING BRANCH BREAKER CONDUIT COEFFICIENT of UTILIZATION CABINET CABLE TELEVISION COAXIAL CIRCUIT BREAKER COMMUNICATIONS CONTRACTOR CURRENT CARRYING CONDUCTOR CLOSED CIRCUIT TELEVISION CALIFORNIA ELECTRIC CODE / CALIFORNIA BUILDING CODE COMMONWEALTH EDISON CHICAGO HOUSING AUTHORITY COMMONWEALTH EDISON COMPANY COMPRESSOR CONNECTED CONVENIENCE CONTROLLED RECEPTACLE CURRENT TRANSFORMER COPPER CABINET UNIT HEATER (for switches) DIMMER SWITCH, DEDICATED DIRECT CURRENT DISCONNECT SWITCH DISTRIBUTION PANEL DOUBLE POLE DOUBLE THROW DOUBLE POLE SINGLE THROW DRAWING ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC HAND DRYER ELEVATION ELECTRIC (ITY) EMERGENCY ELECTRICAL METALLIC CONDUIT EXPLOSION PROOF EQUIPMENT EXISTING TO REMAIN / EXISTING ELECTRIC UNIT HEATER ELECTRIC WATER COOLER / HEATER FUSE or FUSED FIRE ALARM FLOOR BOX FAULT CURRENT / FOOT CANDLE FIRE DEPARTMENT CONNECTION FLUORESCENT FLOOR FAN POWERED BOX FUSED SWITCH GENERATOR GROUND FAULT INTERRUPT GROUNDING ELECTRODE CONDUTOR / GROUND GENERAL PURPOSE GALVANIZED RIGID STEEL CONDUIT HIGH INTENSITY DISCHARGE / HIGH PRESSURE SOD. HORSEPOWER HIGH POINT of FINISHED FLOOR HIGH VOLTAGE HERTZ (cycles per second) INTERNATIONAL BUILDING CODE INTERRUPTING CAPACITY ISOLATED GROUND INTERMEDIATE METALLIC CONDUIT INCANDESCENT JUNCTION BOX (for switches) KEY SWITCH KNOCK-OUT KILOVOLT-AMPERES KILOWATT / KILOWATT HOURS LIGHTNING ARRESTOR LEAD COVERED LOUD SPEAKER LIGHTING LOW VOLTAGE / LOW VOLTAGE CONTRACTOR METER (for switches) MOMENTARY CONTACT MAIN CIRCUIT BREAKER / MAIN FUSED SWITCH MOTOR CONTROL CENTER THOUSAND CIRCULAR MIL MERCURY VAPOR MANUFACTURER MH/M.H. MLO MTD MTR MV METAL HALIDE / MOUNTING HEIGHT MAIN LUGS ONLY MOUNTED MOTOR MULTI-VAPOR N NC / NO NEC NEUT NF NL NEW NORMALLY CLOSED / NORMALLY OPEN NATIONAL ELECTRIC CODE NEUTRAL NON-FUSED NIGHT LIGHT NTS / NIC OH P PA PB NOT TO SCALE / NOT IN CONTRACT OVERHEAD (for switches) PILOT LIGHT PUBLIC ADDRESS PULLBOX PDU PH PNL PRI PROT PT POWER DISTRIBUTION UNIT PHASE PANEL PRIMARY PROTECTION or PROTECTIVE POTENTIAL TRANSFORMER PWR R RC REC RECEP RF POWER RESISTANCE REMOTE CONTROL / ROOFING CONTRACTOR RECTIFIER RECEPTACLE RADIO FREQUENCY RH RT R/RL/RW S S/T SEC RHEOSTAT RAIN-TIGHT REMOVE / RELOCATE / REWIRE SWITCH SHUNT-TRIP SECONDARY SC SPDT / SPST SPEC SN SEPARATE CIRCUIT SINGLE POLE DOUBLE THROW / SINGLE THROW SPECIFICATION SOLID NEUTRAL SS STF SWBD/SWGR SYM / SYS STAINLESS STEEL SEAL TITE FLEX CONDUIT SWITCHBOARD / SWITCHGEAR SYMMETRICAL / SYSTEM T/D T.C. / TC TEL / TEL CL TELEPHONE/DATA TERMINAL CABINET / TIME CLOCK TELEPHONE / TELEPHONE CLOSET TGL TL TOC TR / TO TRANS TOGGLE TWIST-LOCK TOP OF CONDUIT TRIP / THERMAL OVERLOAD TRANSFER MTVTC/MTTC TYP UG / UNG UH UL MAIN TELEVISION / MAIN TELEPHONE TERMINAL CABINET TYPICAL UNDERGROUND / UNGROUNDED UNIT HEATER UNDERWRITERS LABORATORIES UNO UPS V / VA / W UNLESS NOTED OTHERWISE UNINTERRUPTABLE POWER SYSTEM VOLT / VOLT AMPS / WATTS VD VP / VT VOLTAGE DROP VAPOR-PROOF / VAPOR TIGHT WP / WT XFMR / XFM WATER-PROOF / WATER TIGHT TRANSFORMER WH WATT-HOUR BOC BOTTOM OF CONDUIT AFC AVAILABLE FAULT CURRENT BAL BGB BALLAST BUILDING GROUND BOX CLG / CLO CEILING / CLOSET CO/Co. CONDUIT ONLY COMPANY CKT CIRCUIT FAAP / FACP FIRE ALARM ANNUNCIATOR PANEL / CONTROL PNL F&I / F&IBO FURNISHED & INSTALLED / BY OTHERS KA THOUSAND AMPERE KEC KITCHEN EQUIPMENT CONTRACTOR LPS/HPS LOW PRESSURE SODIUM / HIGH PRESSURE SOD. MSB MAIN SWITCHBOARD MM METER MAIN OCPD OVER CURRENT PROTECTION DEVICE SLD SINGLE LINE DIAGRAM ST STEEL FLEX CONDUIT VIF VERIFY IN FIELD WM WIRE MOLD EPO EMERGENCY POWER OFF CFL COMBO FAN LIGHT TVTC / TTC TELEVISION / TELEPHONE TERMINAL CABINET EGC EQUIPMENT GROUND CONDUCTOR SOW SCOPE OF WORK UGPS UNDER GROUND PULL SECTION DRAWING LIST PROJECT VICINITY MAP E0.1 DRAWING INDEX, SYMBOL LIST, GENERAL NOTES, SINGLE LINE DIAGRAM NOTE, PROJECT VICINITY MAP. E1.1 APPLE IL01.N L1 BUILDING FLOOR PLAN, AREA OF WORK. E1.2A ELECTRICAL DETAILS. E2.1 APPLE ROOM A141 POWER PLAN, SCHEDULES, DETAILS, PANEL SCHEDULE. E3.1 APPLE ROOM A141 LIGHTING PLAN, SCHEDULES, DETAILS. E3.2 CA 2019 ENERGY CODE SECTION 130.0 COMPLIANCE FORMS, LIGHTING FIXTURE SCHEDULE. S k07 5 HP, 240V, 1Ø MANUAL MOTOR STARTER - EATON B230AN OR = COS MB ( (M 202 SL CL SL TP F TP-12 5-30R F9 DEVICES RACEWAY AND WIRING FIRE ALARM GENERAL ALARM DEVICE / GENERAL ALARM DEVICE WITH VISUAL ALARM DEVICE PRE-SIGNAL ALARM DEVICE / PRE-SIGNAL ALARM DEVICE WITH VISUAL ALARM VOICE COMMUNICATION SPEAKER / BEACON VOICE COMMUNICATION SPEAKER WITH VISUAL ALARM DEVICE (PER FIRE PREVENTION) REMOTE ANNUNCIATOR LAMP FOR SYSTEM SMOKE DETECTOR NOT USED HVAC DUCT SMOKE DETECTOR MANUAL PULL STATION SPRINKLER WATERFLOW INDICATOR SPRINKLER ALARM VALVE ATTACHMENT SPRINKLER PRESSURE SWITCH HALON EXTINGUISHING SYSTEM DRY CHEMICAL EXTINGUISHING SYSTEM MAGNETIC/ELECTRONIC DOOR ELECTRIC DOOR LOCK CITY FIRE ALARM BOX CENTRAL STATION TIE AND DISCONNECT FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL FIRE ALARM CONTROL PANEL / FIRE ALARM ANNUNCIATOR PANEL VOICE COMMUNICATION CONTROL PANEL ELEVATOR STATUS/CONTROL PANEL HVAC DUCT FIRE DAMPER CONTROL VISUAL ALARM DEVICE SELECTED DEVICES HEAT DETECTOR (135° FIXED TEMPERATURE/RATE OF RISE) SYSTEM SMOKE DETECTOR WITH INTEGRAL HORN BEAM SYSTEM SMOKE DETECTOR (UL-268) TRANSMITTER BEAM SYSTEM SMOKE DETECTOR (UL-268) RECEIVER WET CHEMICAL EXTINGUISHING SYSTEM GASEOUS EXTINGUISHING SYSTEM HOLD OPEN DEVICE SPRINKLER VALVE SUPERVISORY (TAMPER) SWITCH CITY FIRE ALARM BOX TIE AND DISCONNECT PANEL TROUBLE BELL WITH TEST AND SILENCE SWITCH WITH LAMP A AV SV V RA SD SD S WF AV PS HES DES WES GES H VSS CBT CST FACP VCP ECP D FA TB SD T SD R SIGNAL SYMBOLS INTERCOM (wall or ceiling mount) TELEPHONE TERMINAL CABINET BUZZER CHIME CLOSED CIRCUIT TELEVISION CAMERA AMPLIFIER MICROPHONE JACK VOLUME CONTROL MOTION SENSOR CARD READER (verify exact location) See Security and Architectural Specifications ELECTRIC STRIKE (verify exact location) See Security and Architectural Specifications KEYPAD (verify exact location) See Security and Architectural Specifications DOOR RELEASE SECURITY DOOR CONTACT EMERGENCY PANIC STATION TELEPHONE ENTRY SYSTEM TELEPHONE/DATA DEVICES TELEPHONE / DATA COMBINATION WALL OUTLET AS NOTED ON PLANS. TELEPHONE OUTLET (poke-thru) See Telephone/Data specifications. DATA OUTLET (poke-thru) See Telephone/Data specifications. TELEPHONE/DATA COMBINATION OUTLET (poke-thru) See Telephone/Data specifications. WALL MOUNTED TELEPHONE / PUBLIC PAY PHONE GROUND WIRE CONCEALED IN CEILING OR WALL CONDUIT RUN CONCEALED IN OR BELOW FLOOR ARROWHEAD DENOTES HOMERUN TO PANELBOARD. CONDUIT RUN CONCEALED IN CEILING OR WALL ARROW IMPLIES DIRECT PATH TO DESIGNATED PANEL TICK MARK INDICATE QUANTITY OF WIRE: PHASE AND SWITCH LEGS DENOTED AS SHORT LINES NEUTRAL DENOTED AS LONG LINE. GROUND WIRES DENOTED AS LONG LINES WITH DOT CONDUIT STUBBED UP / CONDUIT STUBBED DOWN JUNCTION BOX (wall or ceiling mounted) EQUIPMENT TAG CONDUIT SEAL MULTI-OUTLET ASSEMBLY WIREWAY CABLE TRAY BUSWAY (BUSDUCT) CABLE TAP BOX FLEXIBLE CONDUIT JUNCTION BOX (exposed or in ceiling) UNDERFLOOR DUCT SYSTEM: DIFFERENT TYPES OF OUTLETS OR MANHOLE / HANDHOLE INDICATES POWER DUCT INDICATED TELEPHONE DUCT INDICATES SYSTEM DUCT CONNECTIONS TO UNDERFLOOR DUCT SYSTEM. VARIOUS SYMBOLS IDENTIFY LOCATION OF PULLBOX LIGHTING TRACK LIGHTING WITH TRACK AND FIXTURE STRIPLIGHT ON EM CIRCUIT OR 90 MINUTE BATTERY RECESSED DOWNLIGHT ON EM CIRCUIT OR 90 MINUTE BATTERY EMERGENCY BATTERY PACK LIGHT / REMOTE HEAD EM LIGHT RECESSED DOWNLIGHT / RECESSED DOWNLIGHT WALL WASHER PENDANT MOUNTED FIXTURE 2 x 2 / 2 X 4 FLUORESCENT FIXTURE 1 x 4 FLUORESCENT FIXTURE STRIPLIGHT 2 x 4 FLUORESCENT FIXTURE ON EM CIRCUIT OR 90 MINUTE BATTERY MC = MOMENTARY CONTACT 3W = 3-WAY SINGLE POLE TOGGLE SWITCH 4W = 4-WAY 2P = TWO POLE 3P = THREE POLE LV = LOW VOLTAGE DIMMER SWITCH (wattage rating on plan) PHOTOCELL THERMOSTAT, 44" TO TOP OF STAT LOCKOUT SWITCH / PUSH BUTTON PUSHBUTTON STATION WITH ONE / TWO / THREE BUTTONS KEY-RESET CONTROL STATION STOP-LOCK PUSHBUTTON STATION EMERGENCY POWER OFF MUSHROOM BUTTON SINGLE RECEPTACLE (wall mounted @ 18" AFF to center, UNO) DUPLEX RECEPTACLE (wall mounted @ 18" AFF to center, UNO) DOUBLE DUPLEX RECEPTACLE (wall mounted @ 18" AFF to center, UNO) PUSHBUTTON STATION WITH TWO BUTTONS AND PILOT LIGHT SINGLE RECEPTACLE (flush floor mounted) DUPLEX RECEPTACLE (flush floor mounted) DOUBLE DUPLEX RECEPTACLE (flush floor mounted) SINGLE RECEPTACLE (poke-thru) / DUPLEX RECEPTACLE (poke-thru) DOUBLE DUPLEX RECEPTACLE (poke-thru) RECEPTACLE CONNECTED TO CELLULAR FLOOR SYSTEM SPLIT WIRED DUPLEX RECEPTACLE (wall mounted @ 18" AFF to center, UNO) RECEPTACLE MOUNTED ABOVE COUNTERTOP 20A COMBINATION USB RECEPTACLE, LEVITON T5832-W, OR EQUAL CLOCK OUTLET AND CLOCK FOR INTEGRATED CLOCK SYSTEM WP = WEATHERPROOF EX = EXPLOSION PROOF T = THERMAL OVERLOAD P = PILOT LIGHT D = DIMMING SWITCH K = KEY OPERATED W MH PB TES AMP TTC CH VC MS CR ES KP DR DC EP M T PC J CTB SL KR I UP DN J W W W CT CT CT B B B NAC DUCT SMOKE DETECTOR REMOTE TEST SWITCH WITH HORN AND LIGHT.SS RT POWER DISTRIBUTION BOARD (surface mounted) METER (surface mounted) PANELBOARD (surface mounted) PANELBOARD (recessed mounted) MOTOR (rating as indicated) FUSED DICONNECT SWITCH NON-FUSED DISCONNECT SWITCH COMBINATION MOTOR STARTER AND MAGNETICALLY HELD CONTACTOR OR MOTOR CONTROL CENTER FUSED DISCONNECT: SWITCHGEAR, SWITCHBOARD, C F ELEVATOR SELECTOR SWITCH FURNISHED BY ELEVATOR CONTRACTOR. INSTALLED BY E.C. EL SS "FB" INDICATES FLOOR BOX WITH BLANK COVER HANDS FREE COMMUNICATIONS DEVICE AT AREA OF RESCUER ASSISTANCE. MECHANICALLY HELD, ELECTRONICALLY OPERATED RELAYR RECEPTACLE 250V 1Ø 3W RECEPTACLE 3Ø 5W T V DT V T = CATV (CABLE TELEVISION) D = DATA COMBINATION OUTLET (wall mounted) V = VOICE (TELEPHONE) T = CATV (CABLE TELEVISION) COMBINATION OUTLET (wall mounted) V = VOICE (TELEPHONE) NETWORK INTERFACE DEVICENID PHOTOCELL FOR CONTROL OF LIGHTING DUSK TO DAWN. INTERMATIC K4100 SERIES EQUAL TO ASCO 917 SERIES. CONTROL PANEL FURNISHED WITH OCPCPAND PREWIRED WITH EQUIPMENT J B JUNCTION BOX (ceiling mounted - FAN RATED) W/ DECORATIVE COVER. MULBERRY #40430 GENERATOR ANNUNCIATOR PANELGAP J FA JUNCTION BOX W/ BLANK COVER & 1"c ROUTED TO FACP FOR EXTENSION OF FUTURE FA SYSTEM PAINTED RED & STENCIL "FIRE ALARM" "D" INDICATES MOTOR OPERATED DAMPER VARIABLE FREQUENCY DRIVE (VFD) STARTER 1Ø &/OR 3Ø FURNISHED BY OTHERS, RECEIVED & INSTALLED BY E.C.VFD CONTROL PANEL FURNISHED WITH PACKAGE EQUIPMENTCP NEMA SIZE 1 - UP TO 10HP 480V 3Ø NEMA SIZE 2 - UP TO 25HP 480V 3Ø NEMA SIZE 3 - UP TO 50HP 480V 3Ø NEMA SIZE 1 - UP TO 7 1/2HP 208V 3Ø NEMA SIZE 2 - UP TO 15HP 208V 3Ø NEMA SIZE 3 - UP TO 30HP 208V 3Ø EXIT/DIRECTIONAL SIGN 2-WAY COMMUNICATIONS DEVICE WITH AUDIBLE & VISUAL SIGNAL. ROUTE 3/4" CONDUIT TO TELEPHONE TERMINAL BOARD FOR CONNECTION TO AUTOMATIC DIALER FOR "911", TYP. VERIFY EXACT REQUIREMENTS WITH THE CITY OF CHICAGO FIRE DEPARTMENT AND COMPLY WITH THE IBC. W OS DS / FIXTURE TAG - TEXT DENOTES FIXTURE TYPE, CKT, SWITCH CONTROL LEGRAND SINGLE POWER FLOOR BOX #RFB2 (OR =) W/COVER. UNO. COORDINATE LOCATION, COLOR & ALL REQUIREMENTS WITH GC. LEGRAND COMBO POWER / DATA FLOOR BOX #RFB2 (OR =) W/COVER. PLATE, UNO. COORDINATE LOCATION, COLOR & ALL REQ'S WITH GC. WALKER COMBO POWER / DATA POKE THRU #RC700 SERIES (OR =) WITH COVER PLATE, UNO. COORDINATE LOCATION, COLOR & ALL REQ'S W/GC. UNO, 30A, 208V, L6-30R CORD CAP S.O. CORD DROP, REFER TO PLANS. UNO, 30A, 208V, L15-30R CORD CAP S.O. CORD DROP, REFER TO PLANS. UNO, 20A, 120V, FOURPLEX CORD CAP S.O. CORD DROP, REFER TO PLANS / HH JUNCTION BOX / WALL JUNCTION BOX FURNITURE PARTITION BASE FEED JB, ONE FOR POWER, ONE FOR DATA, J/ SIZED PER CODE, INSTALLED @ 18" AFF, UNO. INSTALL 3/4" FOR POWER & 1" (VIF) DATA CONDUIT STUBBED INTO CEILING CAVITY. FURNITURE PARTITION POWER POLE JB IN CLG, SIZED PER CODE. POWER POLE F&I BY FURNITURE CONTRACTOR, WIRED BY THE EC. COORDINATE ALL REQUIREMENTS & LOCATION WITH THE FURNITURE CONTRACTOR. WIREMOLD 30TP2 POWER POLE, UNO. REQUIRED POWER PER THE PLANS. / 2 x 2 FLUORESCENT FIXTURE ON EM CIRCUIT OR 90 MINUTE BATTERY 1 x 4 FLUORESCENT FIXTURE ON EM CIRCUIT OR 90 MINUTE BATTERY / CEILING MOUNT OCCUPANCY SENSOR, WATT STOPPER #W2000A OR = / WALL MOUNT OCCUPANCY SENSOR, WATT STOPPER #W1-300 OR = / CEILING MOUNT DAYLIT SENSOR, WATT STOPPER OR =. UTILITY COMPANY KWH METER NOT USED- APARTMENT MEDIA BOX BRANCH CIRCUIT / FEEDER TAG. REFER TO CORRESPONDING FEEDER SCH. SPECIAL RECEPTACLE, FLUSH WALL MOUNT, 18"AFF UNO. NUMBER NEXT TO DEVICE IS NEMA#. VIF TYPE & LOCATION WITH GC PRIOR TO INSTALL. PS PSV H M FIRE ALARM MINI HORN / FIRE ALARM MINI HORN STROBE DEVICE FIRE ALARM AUDIO VISUAL DEVICE S B LOCAL SMOKE DETECTOR WITH BATTERY BACKUP & FA SYSTEM INTERFACE EC TO PROVIDE TYPICAL "RING & STRING". CABLE TYPE: CAT6E BY OTHERS. TV TELE DATA WALL OUTLET AS NOTED ON PLANS. (3/4" EMT STUB INTO CLG) P AV UNIT LOAD CENTER, FLUSH MOUNT HOME NETWORK CENTER, FLUSH MOUNT, VERIFY HEIGHT AFF IN FIELD J FBF J PP J S / / S ** S 2 HP,1Ø MANUAL MOTOR STARTER - SQD CLASS 2510, TYPE K01 / K02 OR = S 30A, 3Ø MANUAL MOTOR STARTER - SQD CLASS 2510,TYPE K06 OR = S WATT STOPPER TS200 (SPST) ELECTRONIC IN WALL TIMER SWITCH, OR = S LO P1-1,3,5 CONDUIT HOMERUN TO PANEL WITH FEEDER TAG FOR CONDUIT & WIRE F5 LOCAL COMBO C.O / SMOKE DETECTOR WITH BATTERY BACKUP & FA/ / / / / LOCAL SMOKE DETECTOR WITH BATTERY BACKUP & FA SYSTEM INTERFACE, AND WITH INTEGRAL SOUNDER DEVICE TO PROVIDE 70 DECIBELS AT PILLOW / / GFI DUPLEX RECEPTACLE / GFI DOUBLE DUPLEX RECEPTACLE (wall mount) WP WP GFI DUPLEX RECEPTACLE (wall mounted @ 18" AFF to center, UNO) / NOT USED- NOT USED- "A" H1-6a FAAP / - HD DD / ( (GF GROUND FAULT CURRENT SENSING CT'S FOR MAIN GROUND FAULT BREAKER S SYSTEM INTERFACE 200kA SURGE PROTECTION DEVICE - EATON SPD-200-480Y-2-K FOR 480V, OR =.SPD 200kA SURGE PROTECTION DEVICE - EATON SPD-200-208Y-2-K FOR 208V, OR =. S 1 HP, 1Ø THERMAL MOTOR STARTER - SQD CLASS 2510,TYPE F02 OR = / / CEILING MOUNT HALLWAY OCC SENSOR, WATT STOPPER #W2000H OR = USB CABLE TYPE: CAT6E. (CABLE BY OTHERS). EC TO PROVIDE PULL STRING. TV WALL OUTLET AS NOTED ON PLANS. (3/4" EMT STUB INTO CLG) CABLE TYPE: RG6 COAX. (CABLE BY OTHERS). EC TO PROVIDE PULL STRING. AV WALL OUTLET AS NOTED ON PLANS.(2G JB & 1" EMT STUB INTO CLG, VIF) CABLE TYPE: VIF (CABLE BY OTHERS) TELE DATA FLOOR OUTLET AS NOTED ON PLANS. CABLE TYPE: CAT6E. (CABLE BY OTHERS) TV FLOOR OUTLET AS NOTED ON PLANS. CABLE TYPE: RG6 COAX. AV FLOOR OUTLET AS NOTED ON PLANS. CABLE TYPE: CAT6E, VIF. (wall mounted @ 18" AFF to center, UNO) S 3 HP,1Ø MANUAL MOTOR STARTER - SQD CLASS 2510, TYPE K05 OR = 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E0.1 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 GE N E R A L N O T E S , S Y M B O L S , A B B R E V I A T I O N S , 1 - L I N E 1 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:26:48 -07'00' Arnold Hom 06/23/21 APPLE IL01 LEVEL 1 FLOOR PLAN SCALE: 1" = 12' - 0"E1.1 1 1 E2.1 STAIR ELEV. MECH. MECH. MECH. STAIR BELOW TO OPEN ELEV. COMPAC T O R SHOWER SHOWER STAIR MECH. STAIR COMPANY STORE P124 OFFICE N121 TELECOM STORAGE N119 DATA/ COMM. P122 SECURITY P120 ECS SKINNY LAB MECHANICAL N115 ELECTRICAL ROOM N113 COPY/MAIL ROOM N113A DRY CLEANING P118 GVS NOC ROOM P119 INTERVIEW P115 VENICE CONFERENCE ROOM P117 ROME CONFERENCE ROOMP113 OH-LA-LA CAFE P111 VENDING P1 1 6 EH S RO O M ELEVATOR ELEVATOR ELEVATOR R111 OCR R113 OCR R115 OCR R117 OCR R119 OCR R121 OCR R120 OCR R118 OCR R116 OCR R114 OCR R112 OCR S107 OFFICE x2 P161 OCR P159 OCR P162 OCR P158 OCR P160 OCR S105 EY CONFERENCE ROOM S103 S101 S104 S102 S100 ERNST & YOUNG T1001 T1002 T1003 T1004 T1005T1006 T1007 T105 T106 OCR T101 OFFICE T107 WAREHOUSE STORAGE T108T110 N107 N112 N114 MEN N116 WOMEN S124 TELECOM S122 JANITOR S120 ELECTRICAL N109 N110 BOULDER CREEK VIDEO CONFERENCE ROOM N109A STOR. N108 LONDON CONFERENCE ROOM A105 LOBBY ATRIUM LOUNGE D136 D135 OFFICEx2 D137 BADGING STUDIO D127 DROP ZONE LAB A112 SINGAPORE CONFERENCE ROOM D129 STORAGE D123 MEN D121 WOMEN D113 D115 STORAGE D111 SECURITY OFFICE A116 ELECTRICAL D117 ELECT. D112 COFFEE A138 A136 A134 A111 HONG KONG CONFERENCE ROOM A1 1 3 MO M ' S RO O M B134 VIPER B136 MERLIN B138 COUGAR B140 ICE MAN B142 MAVERICK B135 INTERVIEW CENTER B133 B130 WOMEN B132 MEN B128 DEVELOPER RELATIONS BRIEFING CENTER B127 SERVER ROOM B126 PROJECTION ROOM B121 BEIJING CONFERENCE ROOM B113 STORAGE B111 MEN B109 WOMEN A133 TELECOM MDF/MPOE B114 A141 OFFICE A142 OFFICE STORAGE (DEVILBISS / MODULES) A143 LOADING DOCK REST ROOM P1 1 9 A IN T E R V I E W P125 CONFERENCE ROOM P132 OFFICE P134 CONFERENCE ROOM P135 OFFICE P133 OFFICE P131 OFFICE P1036 P1037 P1038 P1039 P1040 P1041 P1010 P1014 P1012 P1015 P1013 P1016 P1042 P1017 P1018 P1019 P1022P1021 P1020 P1043 P1044 P1023 P1024 P1025 P1028P1027 P1026 P1045 P1029 P1030 P1031 P1034P1033 P1032 P1035 N157 78 9 10 11 12 13 14 15 16 17 18 A B B.3 C D D.3 D.5 D.7 D.8 D.9 E F F.1 F.2 F.5 F.7 G H 1 E3.1 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E1.1 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 AP P L E I L 0 1 L E V E L 1 F L O O R P L A N , A R E A O F W O R K 2 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:26:21 -07'00' Arnold Hom 06/23/21 1. Floor or Wall Assembly - Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 26 in. See Concrete Blocks (CAZT) category in Fire Resistance Directory for names of manufacturers. 2. Metallic Sleeve (Optional) - Nom 24 in. diam (or smaller) Schedule 40 (or heavier) steel pipe cast or grouted into floor or wall assembly, flush with floor or wall assembly. 3. Through Penetrants - One metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor or wall assembly. The annular space shall be min 0 in.(point contact) to max 2-1/4 in. The following types and sizes of metallic pipes or tubing may be used: A. Steel Pipe - Nom 20 in. diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 20 in. diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in. diam (or smaller) steel electrical metallic tubing or nom 6 in. diam (or smaller) steel electrical metallic tubing or nom 6 in. diam (or smaller) steel conduit. D. Copper Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe. 4. Firestop System - The firestop system shall consist of the following: A. Packing Material - Min. 4" thickness of min 4.0 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top end of sleeve for floors or from both ends of sleeve for walls as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* - Sealant - Min 1/2" thickness of fill material applied with the annulus, flush with the top end of the sleeve for floors, or with both ends of the sleeve for walls. Min 1/2" thick bead of all material to be installed around pipe at interface of sleeve for point contact installations. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS-ONE SEALANT *Bearing the UL Classification Marking FIRESTOP SYSTEMS R Underwriters Laboratories, Inc. Reproduced by HILTI, Inc. Courtesy ofJuly 18, 2011 R C AS S F ED C US Page: 1 of 1 %%USECTION A-A%%UTOP VIEW A 2 L Rating At Ambient - Less Than 1 CFM/sq ft 3 4B A L Rating At 400 F - 4 CFM/sq ft T Rating - 0 Hr F Rating - 3 Hr System No. C-AJ-1155 4A 4B 1 CA J 1 1 5 5 %%UTOP VIEW 1. Floor or Wall Assembly - The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw-attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 in. higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* 5/8 in. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32-1/4 in. for steel stud walls. Max diam of opening is 14-1/2 in. for wood stud walls. The F Rating of the firestop system is equal to the fire rating of the wall assembly. 2. Through-Penetrants One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. An annular space of min 0 in. to max 2-1/4 in. is required within firestop system. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe - Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe - Nom 30 in diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. 3. Fill, Void or Cavity Material* - Sealant Min 5/8 in. or 1-1/4 in. thickness of fill material applied within the annulus, flush with both surfaces of wall for 1 or 2 hr walls, respectively. At the point contact location between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe covering/wall interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS-ONE SEALANT *Bearing the UL Classification Marking FIRESTOP SYSTEMS Page: 1 of 1 Underwriters Laboratories, Inc.Reproduced by HILTI, Inc. Courtesy ofR October 14, 2015 R C AS S F ED C US C A J 1 0 5 4 %%USECTION A-A 2 A 1B L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400 F - 4 CFM/sq ft F Rating - 1 & 2 Hr (See items 1 & 3) System No. W-L-1054 T Rating - 0 Hr 3 A 1A \A 1 ; 7 / 8 " \A1 ; 5 3 / 4 " \A1 ; 4 1 / 4 " \A1;2 15/16"\A1;8 7/8"\A1;3 3/16"\A1;7 5/16"\A1;3 3/16" \A1;10 3/4" \A1 ; 8 1 / 8 " \A1;3 5/16" \A1;10 3/4" \A 1 ; 4 9 / 1 6 " \A 1 ; 5 " \A 1 ; 5 1 / 8 " LEGRAND OMNIBOX #880-S2 LEGRAND OMNIBOX TRIM, VIF WITH CUSTOMER / GC POKE THRU-FLOOR BOX-POWER POLE SCALE: N.T.S. 7 TYP. SEISMIC ANCHORING DETAILS SCALE: N.T.S. 4 USE IF &/OR AS APPLICABLE \A1 ; 9 " {TYPICAL LINEAR LTG. SUPPORT. SEE FIXTURE SCH. ON SHEET E3.2 FOR HEIGHT AFF. AS APPLICABLE} \A 1 ; 2 . 5 " (E) T-BAR GRID LINEAR LTG COMPLETE INSTALLATION DETAIL, VIF. ALL INSTALLATIONS SHALL COMPLY W/FIXTURE SPECIFICATIONS & ALL ARTICLES OF NEC. TY P I C A L AI R C R A F T CA B L E D R O P , 3 PE R F I X T U R E , VI F AIR CRAFT CABLE BY {FINELITE} 1/4"-20 STUD BY {FINELITE} SLIP RING & SET SCREW BY {FINELITE} CLG CABLE RE- TAINER/{FINELITE} SJT CORD BY {FINELITE} 4" S Q . BO X BY E C TY P I C A L P O W E R CA B L E D R O P , ON E P E R R O W (E) T-BAR GRID 1/2" FLEX ADAP- TER BY {FINELITE} 5" CANOPY BY FINELITE STRAIN RELIEF BY {FINELITE} RE T A I N E R RI N G BY FI N E L I T E #12GA. CEILING WIRE TO 4x PURLIN, VIF. 3 PER 12' FIXTURE (E) T-BAR GRIDID S CA D D Y BY LE D A L I T E 1/2" FLEX BY EC(E) T-BAR GRID {TYPICAL HID HIGH BAY FIXTURE. SEE FIXTURE SCH. ON SHEET E3.2 FOR HEIGHT AFF. AS APPLICABLE} {HIBAY FIXTURE PER DRAWINGS} {\Fromans.shx|c0;LOOP CORD & PLUG} {INSTALL J-BOX WITH 15A, 277V(VIF) TWIST LOCK RECEPTACLE, MATCH FIXTURE {TYPICAL FL. HIGH BAY FIXTURE. SEE FIXTURE SCH. ON SHEET E3.2 FOR HEIGHT AFF. AS APPLICABLE} {\Fromans.shx|c0;ROOF DECK} {BRANCH CIRCUIT PER DRAWINGS} {ATTACH FIXTURE TO GLUELAM VIA 3/8x4" LAG EYE BOLT} {#12 SAFETY JACK CHAIN} {\Fromans.shx|c0;GLUELAM BEAM} {C A D D Y 4H 5 8 BE A M CL A M P , {#12 JACK CHAIN} {FIXTURE HANGER} {14/3 SO CORD & TL PLUG INTEGRAL W/FIXTURE. STRAP CORD TO CHAIN WITH TIE WRAPS.} {4SQ. BOX SECURED TO BAR JOIST, WITH TLOCK RECEPTACLE.} {( E ) B A R J O I S T OR WO O D 4 x PU R L I N } {SEISMIC CLIP OR METAL SCREW @ EACH CORNER, VIF W/INSPECTOR} {TYPICAL GRID TROFFER FIXTURE. SEE FIXTURE SCH. ON SHEET E3.2 FOR HEIGHT AFF. AS APPLICABLE} {\Fromans.shx|c0;CEILING GRID ASSEMBLY} \A1;VIF {FOR LIGHT FIXTURES < 56#, 2-12 GA. HANGAR WIRES @ OPPOSITE CORNERS REQ'D. FOR LIGHT FIXTURES > 56#, 4-12 GA. HANGAR WIRES ARE REQ'D. (1 @ EACH CORNER) INSTALL WIRES SLACK. INSTALL SHALL COMPLY WITH 2019 CBC {TYPICAL FL. HIGH BAY FIXTURE. SEE FIXTURE SCH. ON SHEET E3.2 FOR HEIGHT AFF. AS APPLICABLE} {#12 JACK CHAIN} {FIXTURE HANGER} {C A D D Y 4 H 5 8 BE A M C L A M P , TY P E V I F . } {1 2 / 3 M C C A B L E , ST R A P C A B L E T O JA C K C H A I N W I T H CA B L E T I E W R A P S } {(E)BARJOIST OR WOOD 4x PURLIN} {4 S Q . B O X SE C U R E D TO B A R J O I S T , WI T H TL O C K RE C E P T A C L E . } {RECESSED GRID TROFFER} USE IF &/OR AS APPLICABLE TYPICAL LIGHTING FIXTURE DETAILS SCALE: N.T.S. 9 TYPICAL HILTI FIRESTOP DETAILS SCALE: N.T.S. 5 ABOVE HILTI FIRE STOP DETAILS REFLECTED FOR CONCEPTUAL PURPOSES. APPROVED EQUALS ARE ACCEPTABLE. USE IF &/OR AS APPLICABLEUSE IF &/OR AS APPLICABLE H3 H2C G B A X3 X2 X0 B C AN G H1 X1 EQUIPMENT GROUNDING CONDUCTOR (EGC), SIZED PER NEC 250-122. GROUNDING ELECTRODE COND. (GEC). PER NEC 250.30.A.4 & A.5, THE BUILDING OR STRUCTURE GROUNDING ELECTRODE SYSTEM (GES) TO BE USED AS THE GROUNDING ELECTRODE FOR THE SEPARATELY DERIVED SYSTEM. PER 250.68.C.1 & C.2, APPROVED WATER PIPING &/OR BLDG STEEL MAY BE USED AS EXTENSION OF THE GES. EQUIPMENT GROUNDING CONDUCTOR (EGC), SIZED PER NEC 250-122. BOND TO ENCLOSURE WITH LAYIN LUG DRY TYPE XFMR ENCLOSURE SH I E L D ( W H E R E A P P L I C A B L E ) SEE SLD ON SHEET E0.1 FOR ALL GROUNDING METHODS & GROUND CONDUCTOR SIZES. ALL XFMR & SERVICE GROUNDING & BONDING & CONNECTIONS TO COMPLY WITH 2017 NEC (2019 CEC) ART 250, & SPECIFICALLY W/250.28, 250.30, 250.50, 250.53, 250.64 & 250.104. SE C O N D A R Y C O N D U C T O R S PE R T H E D R A W I N G S PR I M A R Y C O N D U C T O R S PE R T H E D R A W I N G S MAIN BONDING JUMPER(MBJ) PER 250.30.A.1, 250.28.A-D TYPICAL DRY TYPE XFMR GROUNDING DETAIL TYPICAL SERVICE GROUNDING DETAIL 480V,3%%C,Δ 208Y/120V,3%%C BOND JUMPER PER 250.104.B MAIN BOND JUMPER COND (MBJ)PER NEC 250.28.A-D METAL UG WATER PIPE GRND ELECTRODE IN DIRECT CON- TACT W/THE EARTH FOR AT LEAST 10', PER 250.52.A.1 >20' 1/2" DIAM. CONCRETE ENCASED GRND ELECTRODE (UFER &/OR GROUND RING) PER NEC ART. 250.52.A.3&4 MINIMUM #4 AWG BARE CU PER NEC ARTICLE 250.52.3 #6 AWG CU BJ PER 250.53.E IF APPLICABLE, MIN. 8'x5/8" CU ROD ELECTRODE PER NEC ARTICLE 250.52.A.5 GROUND ELECTRODE COND (GEC)CONNECTION WITHIN 5' OF PIPE ENTRANCE IN TO BLDG PER 250.52.A.1 BLDG. STEEL MAIN SWITCH BOARD ENCLOSURE EQ U I P GR N D BU S NEUT BUS GROUND ELECTRODE COND (GEC)PER NEC 250.64-66 #6 CU-30/45 KVA #2 CU-75 KVA #1/0 CU-112.5 KVA #1/0 CU-150 KVA #2/0 CU-225 KVA #3/0 CU-500 KVA #3/0 CU-750 KVA EQUIP BOND JUMPER PER NEC 250.102 #1 0 C U - 6 0 A #8 C U - 1 0 0 A #6 C U - 2 0 0 A #4 C U - 3 0 0 A #2 C U - 4 0 0 A #1 C U - 6 0 0 A #1 / 0 C U - 8 0 0 A #2 / 0 C U - 1 0 0 0 A #3 / 0 C U - 1 2 0 0 A #4 / 0 C U - 1 6 0 0 A #2 5 0 C U - 2 0 0 0 A #3 5 0 C U - 2 5 0 0 A #10 CU-60A #8 CU-100A #6 CU-200A #4 CU-300A #2 CU-400A #1 CU-600A #1/0 CU-800A #2/0 CU-1000A #3/0 CU-1200A #4/0 CU-1600A #250 CU-2000A #350 CU-2500A +6'-0" AFF VERIFY TOP/BOTTOM SECT 1 & MLO OR MCB BEFORE MFGR. METAL DIRECTORY HOLDER LATCH & KEY BREAKERS DOOR OVER LOCK TRIM DEAD FRONT NAMEPLATE BREAKERS TOGETHER FOR SURFACE MOUNTING. SPACE CANS (4) 1/4x20 BOLT CANS 1.5" APART FOR FL MNT 3" CLOSE NIPPLE WITH BUSHINGS MAIN LUGS OR M C B FEED THRU SECTION 1 LUG S SECTION 2MAIN LUGS \A1;20" STUD \A 1 ; 6 " 3/4" ALL AROUND TRIM OVERLAPS FLUS H \A1;20" SURFACE \A 1 ; 6 " TYPICAL PANEL BOARD DETAIL SCALE: N.T.S. 1 USE IF &/OR AS APPLICABLE TYPICAL XFMR GROUNDING DETAILS SCALE: N.T.S. 2 USE IF &/OR AS APPLICABLE TYPICAL UG TRENCH DETAIL SCALE: N.T.S. 3 USE IF &/OR AS APPLICABLE LEGRAND SERIES RC700 POKE THRU FOR FLUSH DEVICE OR FLUSH FURNITURE FEED \A 1 ; 1 0 ' 5 " - 1 2 ' 5 " \A 1 ; 1 5 . 2 5 " COMMUNICATION SECTION/DEVICES POWER SECTION WITH DEVICES WI R E M O L D P P 30 T P - 2 V 30 T P - 4 V 25 D T P - 4 1 2 , PP T Y P E & DE V I C E S P E R PO W E R P L A N \A1;2 3/4" \A1;1 7/8" COMMUNICATIONS PO W E R \A 1 ; 1 1 7 / 3 2 " \A1;3" MIN. CLEAN SAND CONDUIT SIZE ANDQUANTITY PER DRWG. RED CAUTION TAPE FINISH GRADE APPROVED 95% COMPACTED FILL UNDISTURBED SOIL ABOVE PG&E GREEN BOOK DETAILS & SPECIFICATIONS ARE REFLECTED FOR REFERENCE ONLY, & SHALL BE USED IF &/OR AS APPLICABLE. EC SHALL CONFIRM ALL INSTALLATION METHODS & REQUIREMENTS WITH PG&E PRIOR TO ALL Greater depth may be necessary at the riser 30 inches when installed in street area 14 4 1 12 6 Cable 2 1 elevision Primary Secondary 1 1 NA1 1 5-12 12 6 1 10-30-00 18 2 24 1,2000 . #08: 30 2 6 1 December 063928 3 of 4 Electric Customer Underground Commercial ertical Radius The number of cables per phase is based on 80% of the panel nameplate rating. This does not apply to panels rated Service rating shall be the termination section, pullcan, service section, or main service switch rating, rounded local random, General facilities telephone secondary grouped requirements. between elephone (Conduit) Service clearance betweenspacing facilities. clearance maintained between is Gas T 4 4 NA NA 4 5-1 Joint cover 5. 6. T Gas able clearance underneath and Provide FacilityFacility elephone Buried) (Directelephone (Conduit) backfill cable facilities and grouped allow 1 5-1 istelevision flow tomaterial gasandthe , of facilities nearest to telephone Cover Cable elevision 1 1 4 Secondary Inchesin Electric 1 1 4 Clearanceand T (D i r e c t NA NA 4 Trench elephone Buried) native ypical maintain provisions Gas compaction backfill 5-5.to or(sand T additional facilities and facilities. cable television todepth theto or backfill and diameter level afrom inNotes 1. 3. 4. 2. inch in larger-diameter depths Provide electric reference Provide Ensure 4" 2" ypical rench more not T 18 " iew V S 5-5 occasional than G Design S soil) C T Service containing orstate federal, the ariances to V 128. ofprovisions ifrequired bemay gas ifcover and facilities. facilities are the of sh a l l General any meet conform Order minimums. applicable required facilities a l l of trenchthe within incheswithin 2 rated panel requires bus duct. distances, a bus duct is to be used. a 4-inch for and able 5-1 1,2000 2 3 See ensure between December 1 24 24 18 Cover 12 6 12 Electric V 2 " able Conduit Diameter T 3 Bend 3 " 4 " 5 " 125 200 400 (Amps) 1,000 1,200 1,6 0 0 Service 4,000 2,0 0 0 1 1/ 2less than 100 126 320 - - 600 800 and 1 cross electric, 12E 1 2,5 0 0 3,0 0 0 3,500 See area. rocks requirements. Order installing " 5 " 5 Duct 5 " 22 1 1 1 2 2 2 3 5 7 2 " 3- " 3 " 3 " 5 " 5 " 5 " 5 " 5 - " Panel 3 5 3 7 3 Buss 8 Copper N/A N/A N/A N/A N/A N/A N/A N/A N/A Conduit Size and Number - ypical fect Other Installing elephone Gas Service (Secondary) Electric elevisionCable G = = S = = C 5-1 for See able Cover and on Page 5-12 " or Clearance Service Cable for Facilities able 1 Other Design this able 2 " or rench Modify to0 600 Volts ypes ype PVC Hot-Dip Galvanized Rigid Steel Schedule Conduit T Approved 40 or 80 and and Conduit for for Requirements Underground Serve Maximum Load 1 Cables to " . for 24 " Construction 24 Horizontal " " " 24 36 36 " " " 36 3660 Copper PhasePhase 1 -1/0 1 -#2 1 -4/0 1 - 1/ 0 1 350 1 4/ 0 2 350 2 4/0 1,000 2 350 -1,000 2 -350 -1,000 3 - 350 - 5 - 350 - 7 - 350 2 2 3 5 7 5 7 1,0 0 0 8 1,000 Neutral N/A N/A N/A N/A N/A N/A N/A N/A 5 250 7 250 8 250 N/A N/A Approval UG-1: PG&E Prior marked Spec. on conduit) DB 120 C80.1 C Owned with (must be for Installing Services Specification USAS Commercial Services Services Greenbook USE IF &/OR AS APPLICABLE TYPICAL CONNECTRAC DETAIL SCALE: N.T.S. 8 USE IF &/OR AS APPLICABLE TYPICAL CORD DROP DETAILS SCALE: N.T.S. 6 #10 AWG SO CORD DROP. CONDUCTOR QUANTITY PER RECEP. TYPE \ A 1 ; 4 8 " , V I F \A1;48", VIF OPEN CEILING INSTALLATION 4 SQ. BOX W/IND. RAISED COVER & DEVICE RECEPTACLE. DEVICES PER PLANS. 3/4" CORDGRIP STRAIN RELIEF, TYP. BOTH ENDS GRID CEILING INSTALLATION 4 SQ. BOX WITH 5/8" MUD RING (E)GRID CEILING 1G STAINLESS STEEL COVER PLATE,TYPICAL 4" SQUARE BOX, SECURED TO (E) ROOF STRUCTURE VIA 1/4"x1" LAGS #12 GAUGE CEILING WIRE CA D D Y 5 1 2 BA R HA N G E R TYPICAL DATA CORD DROP DETAILTYPICAL RECEPTACLE CORD DROP DETAIL CONDUIT PER DWGS 3/4" SEAL TITE FLEX, TYPICAL,VIF 4 SQUARE BOX. DATA DEVICE & WIRING BY OTHERS \ A 1 ; 4 8 " , V I F \A1;48", VIF OPEN CEILING INSTALLATION GR I D CE I L I N G IN S T A L L A T IO N 4 SQ. BOX WITH 5/8" MUD RING (E)GRID CEILING 1G STAINLESS STEEL COVER PLATE,TYPICAL 4" SQUARE BOX, SECURED TO (E) ROOF STRUCTURE VIA 1/4"x1" LAGS #12 GAUGE CEILING WIRE CA D D Y 5 1 2 BA R HA N G E R (E) SLAB ON GRADE CONDUIT PER DWGS #1/0-400A #2-400A INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 SPECIFICATIONS. THE ABOVE BOLT SIZES COMPLY WITH THE 2019 CBC 1617A FOR ANCHORAGE TO CONCRETE. XFMR DIMENSIONS AND WEIGHT MAY VARY FROM ONE MANUFACTURER TO ANOTHER. REFER TO MANUFACTURER'S #4/0 #350 #500 75 75 76 #3/0 #3/0 #3/0 56 #2/0 56 46 #3/0 #3/0 #1-600A #1/0-800A #1-600A 300 150 225 750 500 1000 #2/0-600A 4350 3200 3900 50 36 36 60 44 44 5/8 X 6 5/8 X 6 5/8 X 6 1450 1025 24 31 800 24 20 31 26 1/2 X 5 1/2 X 5 5/8 X 5 INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 INSTALL PER NEC 450 ABOVE TABLE PER 2019 CBC 1617A & ICC ES ESR 1917. SEE HILTI CUT SHEETS FOR SPECIFIC HILTI BOLTCALCS. LOCAL JURISDICTIONS MAY REQUIRE SPECIAL INSPECTION ON EXPANSION ANCHORS PRIOR TO INSTALLATION, GEC #6 #4-300A #4-225A #6-200A #2-400A CU #10 40 40 31 #10 31 CU #1/0 #6 #2 EGC HSECONDARY F19 FEEDER 112.5 45 75 F14 KVA PRIMARY 30 F12 FEEDER F19 / F21 NOTESAPPROX. D W 1/2 X 5 1/2 X 5 1/2 X 5 ANCHOR (4) EACHWT.(LBS) 750 350 500 19 19 14 26 20 26 300 14 20 (N)MSB - APPROXIMATE DIMENSIONS 1745 LBS - 72"W x 39"D x 91.5"H (N)DPL1 - APPROXIMATE DIMENSIONS 3507 LBS - 138"W x 51"D x 91.5"H MSB/DPL1 TO BE ANCHORED TO NEW EQUIPMENT PAD PER EQUIP. SPECS, & STRUCTURAL CALCS AS APPLICABLE. NEW EQUIPMENT PAD 5/8" %%C A307 BOLT 4. 2 5 " MI N \A 1 ; P E R X F M R S P E C NAME T A G NP \A1;PER XFMR SPEC ISOLATION PADS NAME PLATE IF APPLICABLE FOR 30to150 KVA'S 1/2"x5" HILTI KWIK BOLT TZ, TYP OF 4. DRILL & EPOXY HOLE W/HILTI HIT-RE-500 PER 2019 CBC 1617A. \A1;3"\A1;3" 11/16" Holes (E)SLAB ON GRADE OR NEW STRUCTURAL STAND, REFER TO STRUCTURAL CALCS AS APPLICABLE, & 1-E2.1. ABOVE ANCHORAGE REQ'S ARE REFLECTED FOR REFERENCE ONLY. SEE STRUCTURAL DRAWINGS FOR ALL REQ'S. PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE PER FEEDER SCHEDULE 1/2" %%C A307 BOLT FOR 225to750 XFM 5/8" %%C A307 BOLT 5/8" BOLT-225to750 XFM 1/2" BOLT - 30to150 XFM PER FEEDER SCHEDULE PER FEEDER SCHEDULE 1/2 X 5 4- 1 / 4 " MI N . {5/8"x5" HILTI KWIK BOLT TZ, TYP OF 4 EA. DRILL/ EPOXY THE HOLE WITH HILTI HIT-RE-500 PER 2019 CBC SECT. 1617.} {3"x3"x2" 2-HOLE "L"} 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E1.2A 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 E L E C T R I C A L D E T A I L S 3 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:25:49 -07'00' Arnold Hom 06/23/21 IL01.N ROOM A141 POWER PLAN SCALE: 3/16" = 1' - 0"E2.1 1 POWER SCOPE OF WORK FOR ROOM A141 THIS SHEET: PROVIDE (2) 20A, 120V CIRCUITS FOR CUBICLE FURNITURE BASE FEEDS & (1) 20A, 120V, 4PLEX WALL RECEPTACLES USING EXISTING 20A, 120V CIRCUITS IN THIS ROOM. ALSO PROVIDE (1) DATA RING & STRING OUTLET & (1) CARD READER RING & STRING PROVISION.....AS IS REFLECTED IN ABOVE POWER PLAN. COMPLIANCE WITH CA 2019 ENERGY CODE SECTION 130.5.D FOR POWER IS NOT REQUIRED FOR THIS PROJECT PER CA 2019 ENERGY CODE SECTION 141.0.b.2.P.iv . REFER TO THE ARCHITECTURAL DRAWINGS AS APPLICABLE FOR DEMOLITION SCOPE OF WORK. 11 LTG & POWER SHEET NOTES AS APPLICABLE [ ] (SEE ALSO GENERAL NOTES ON E0.1) [1] SEE SINGLE LINE DIAGRAM ON SHEET E0.1, & DETAILS ON SHEET E1.2A, FOR ALL APPLICABLE WIRING &/OR GROUNDING REQUIREMENTS. SEE DETAIL 4 ON SHEET E1.2A FOR SEISMIC ANCHORING REQUIREMENTS ON ALL ELECTRICAL EQUIPMENT EXCEEDING 400 LBS. IN WEIGHT. [2] ALL POWER / DEVICES / LIGHTING THIS ROOM ARE EXISTING, SHALL REMAIN AS IS, & ARE NIC, UNO. [3] PROVIDE CEILING J-BOX WITH REFLECTED CIRCUITS FOR FURNITURE POWER POLE, PP IS F&IBO, & WIRED BY THE EC. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [4] PROVIDE FLUSH WALL J-BOXES FOR POWER & DATA @18" AFF FOR CUBICLE BASE FEED. BASE FEED IS F&IBO, WIRED BY THE EC. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [5] PROVIDE BLDG STANDARD IEM DOOR IN DOOR CU 400A, 208Y/120V, 3Ø, 4W, N1, 100% N, 22 KAIC, 84 CKT, MLO SURFACE MOUNT PANELBOARD. SEE SLD ON SHEET E2.5, & DETAIL 1 & 2 ON E1.2A FOR WIRING / GROUNDING REQUIREMENTS. COORDINATE LOCATION WITH GC & CUSTOMER. EC TO VIF CONDUIT ROUTING PATH FOR NEW PANEL FROM SOURCE, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [6] PROVIDE BLDG STANDARD IEM DOOR IN DOOR CU 150A, 208Y/120V, 3Ø, 4W, N1, 100% N, 10 KAIC, 42 CKT, MLO, SURFACE MOUNT PANELBOARD. SEE SLD ON SHEET E2.5, & DETAIL 1 & 2 ON E1.2A FOR WIRING / GROUNDING REQUIREMENTS. COORDINATE LOCATION WITH GC & CUSTOMER. EC TO VIF CONDUIT ROUTING PATH FOR NEW PANEL FROM SOURCE, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [7] PROVIDE BLDG. STANDARD OR = LEGRAND COMBO FLOOR BOX 880-S2 WITH BRASS COVER PLATE, VIF. PROVIDE 3/4" PVC SCH 40 POWER & DATA CONDUITS FROM BOX TO NEAREST DEVICE AS REFLECTED. ALL SLAB ON GRADE SAW CUTTING & PATCHING F&I BY GC. EC TO VIF THE SLAB IS FREE OF OBSTRUCTIONS PRIOR TO ALL SAW CUTTING. COORDINATE BOX LOCATION / REQUIREMENTS WITH GC. INSTALLATION SHALL COMPLY WITH THE NEC & MANUFACTURERS SPECS. SEE ALSO DETAIL 7-E1.2A ON E1.2A. COORDINATE POWER & DATA CONNECTION TO FURNITURE WITH GC, AS APPLICABLE. [8] PROVIDE LEGRAND POKE THROUGH FITTING RC700-A &/OR RC700-6A, OR APPROVED =. EC TO PROVIDE FLOOR CORE FOR THE FITTING PER THE MANUFACTURER'S SPECIFICATIONS. EC SHALL VIF ANY OBSTRUCTIONS IN THE FLOOR SLAB PRIOR TO CORING. ALL CONDUIT & WIRING SHALL BE INSTALLED IN TENANT SPACE BELOW, & SHALL TERMINATE INTO THE ADJACENT WIRING DEVICE AS REFLECTED. COORDINATE LOCATION & ALL REQ'S WITH THE GC & CUSTOMER. REFER TO DETAIL 7-E1.2A ON E1.2A FOR POKE THROUGH SPECIFICATIONS & PICTURE REFERENCE. PROVIDE DEVICES PER THE DRAWINGS. [9] PROVIDE 120V POWER FOR FRACTIONAL HP CEILING MOUNT EXHAUST FAN, WHICH IS F&IBO, & WIRED BY THE EC. FAN SHALL BE CONTROLLED BY LIGHT SWITCH AS REFLECTED ON SHEET E3.1 & DETAIL 6 ON SHEET E1.2A. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC / MC. [10] PROVIDE 120V, 1Ø POWER IN WALL J-BOX @ 18" AFF(VIF) FOR CONNECTION TO NEW INSTAHOT WATER HEATER. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / PC. [11] PROVIDE 1-GANG FLUSH BOX @ 44" AFF (VIF) WITH 3/4" C. FROM BOX TO >6" ABOVE CEILING FOR NEW CARD READER. CARD READER & WIRING PROVIDED BY OTHERS. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [12] PROVIDE 120V IN CEILING 4SQ. J-BOX FOR CONNECTION TO FIRE-SMOKE DAMPERS. COORDINATE LOCATION & ALL REQUIREMENTS WITH MC / GC & THE MECHANICAL DRAWINGS. [13] PROVIDE 120V IN CEILING 4SQ. J-BOX FOR CONNECTION TO FIRE ALARM SYSTEM EQUIPMENT. COOR- DINATE LOCATION & ALL REQUIREMENTS WITH LIFE SAFETY CONTRACTOR & THE GC. [14] PROVIDE 120V POWER IN CEILING J-BOX & UP/DOWN LV WALL SWITCH CONTROL FOR CONNECTION TO NEW PROJECTOR SCREEN. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC & CUSTOMER. [15] PROVIDE 4PLEX RECEPTACLE FLUSH IN CEILING FOR CEILING PROJECTOR. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC / CUSTOMER. LABEL DEVICES "CEILING PROJECTOR". [16] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO SECURITY SYSTEM CAMERA. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [17] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO 12V DOOR CONTACTS FOR SECURITY SYSTEM. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [18] PROVIDE REFLECTED CEILING CORD DROP AS REFLECTED. SEE APPLICABLE SHEET E1.2A DETAIL FOR INSTALLATION REQUIREMENTS. COORDINATE LOCATION & REQUIREMENTS WITH GC & CUSTOMER. [19] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO ELECTRIFIED MECHOSHADE. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [20] PROVIDE GFI RECEPTACLE WITHIN 25' OF MECHANICAL EQUIPMENT PER NEC ARTICLE 210-63. EXTEND SAME 120V TO ANY APPLICABLE HVAC ACCESSORIES, IE CONDENSATE PUMP & SMOKE DETECTOR. [21] PROVIDE WIREMOLD 30TP-2V OR 30TP-4V OR 25DTP-412(VIF) POWER POLE WITH DEVICES AS REFLECTED ON THE SHEET E2.1. REFER TO DETAIL 7 ON SHEET E1.2A FOR PICTORAL REFERENCE. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [22] NOT USED. [23] PROVIDE 120V SHOW WINDOW RECEPTACLE FLUSH IN CEILING EVERY 12' PER NEC 210.62., 220.14. RECEPTACLES SHALL BE CONTROLLED VIA TC1 AS REFLECTED IN DETAIL 3 SHEET ON E1.2A. [24] ALL ELECTRICAL EQUIPMENT IN THIS ROOM SHALL COMPLY WITH CLEARANCES PER NEC 110.26, VIF. [25] EC TO VIF ALL DEVICE LOCATIONS & REQUIREMENTS IN THIS ROOM WITH GC PRIOR TO INSTALLATIONS. [26] EXISTING SERVER ROOM IS NOT CLASSIFIED & CONSTRUCTED AS AN INFORMATION TECHNOLOGY EQUIPMENT ROOM. THUS, COMPLIANCE WITH NEC / CEC ARTICLE 645 IS NOT REQUIRED. [27] ALL SERVER / IDF ROOM DATA WIRING, IF APPLICABLE, IS F&IBO. EC SHALL VIF WITH GC & CUSTOMER FOR ALL CONDUIT REQUIREMENTS FOR DATA LADDER RACK REQUIREMENTS AS APPLICABLE. [28] PROVIDE 208V, 1Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO EXTERIOR MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. PROVIDE 3/4" CONDUIT WITH PULL STRING FOR CONTROL WIRING FOR HP1 & FC1. [29] PROVIDE 208V, 3Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE GC. [30] PROVIDE 120V, 1Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. FAN TO BE CONTROLLED VIA THE RESTROOM LIGHTING CONTROL, VIF. [31] REFLECTED CIRCUITS (VIF) ARE EXISTING IN CEILING JB FROM PREVIOUS LAYOUT CONFIGURATION. EXTEND EXISTING CIRCUITRY TO NEW & / OR RELOCATED DEVICES AS REFLECTED. VIF ALL REQ'S. [32] PROVIDE MISCELLANEOUS ELECTRICAL DEMO IN THIS ROOM, REFER TO ARCHITECTURAL DEMO PLAN. [33] PROVIDE 480V, 3Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. [34] PROVIDE 30 kVA, 480V Δ TO 208Y/120V, 3Ø, N1, XFMR AT REFLECTED LOCATION. SEE SLD ON E0.1 & DETAIL 2 ON SHEET E1.2A FOR WIRING & GROUNDING REQUIREMENTS. VIF XFMR LOCATION WITH GC. SEE DETAIL 4 ON SHEET E1.2A, & STRUCTURAL DRAWING AS APPLICABLE FOR ANCHORING XFMR TO EX FLOOR SLAB. UPON PROJECT COMPLETION & WITH XFMR UNDER FULL LOAD, VIF XFMR SECONDARY OUTPUT VOLTAGE, & ADJUST TAPS AS REQ'D TO MAINTAIN 208V (L-L) & 120V (L-G). EC TO VIF CONDUIT ROUTING PATH FOR NEW XFMR FROM SOURCE PANEL, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [35] PROVIDE 75 kVA, 480V Δ TO 208Y/120V, 3Ø, N1, XFMR AT REFLECTED LOCATION. SEE SLD ON E0.1 & DETAIL 2 ON SHEET E1.2A FOR WIRING & GROUNDING REQUIREMENTS. VIF XFMR LOCATION WITH GC. SEE DETAIL 4 ON SHEET E1.2A, & STRUCTURAL DRAWING AS APPLICABLE FOR ANCHORING XFMR TO EX FLOOR SLAB. UPON PROJECT COMPLETION & WITH XFMR UNDER FULL LOAD, VIF XFMR SECONDARY OUTPUT VOLTAGE, & ADJUST TAPS AS REQ'D TO MAINTAIN 208V (L-L) & 120V (L-G). EC TO VIF CONDUIT ROUTING PATH FOR NEW XFMR FROM SOURCE, & PROVIDE JB'S AS REQUIRED FOR NEC COMPLIANCE. [36] PROVIDE NEW BUILDING STANDARD (IEM OR APPROVED =) 2000A, 208Y/120V, 3Ø, 4W, N1, 200% N, 50 KAIC, 100%, MCB, SURFACE DISTRIBUTION. PANEL. SEE SLD ON SHEET E2.3 FOR WIRING, GROUNDING & APPLICABLE INSTALLATION REQUIREMENTS. COORDINATE LOCATION WITH THE GC & CUSTOMER. [37]PROVIDE NEW BUILDING STANDARD (IEM OR APPROVED =) 1200A, 480Y/277V, 3Ø, 4W, N1, 50 KAIC, 80%, MLO, SURFACE MOUNT DISTRIBUTION PANEL. SEE SLD ON SHEET E2.3 FOR WIRING, GROUNDING & APPLICABLE INSTALLATION REQUIREMENTS. COORDINATE LOCATION WITH THE GC & / OR MITAC. EC TO VIF CONDUIT ROUTING PATH FOR (N)DPH1 FROM MSB, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [38] PROVIDE 4"x36" ABOVE GRADE GRS CONCRETE FILLED BOLLARD WITH CAP AT REFLECTED LOCATIONS. BOLLARDS SHALL BE PAINTED CAUTION YELLOW & SHALL BE SECURED TO FLOOR VIA (4)5/8"x 4" WEDGE ANCHORS. COORDINATE LOCATIONS/ALL REQ'S WITH GC, & STRUCTURAL DRAWINGS IF APPLICABLE. [39] PROVIDE NEW EATON EUSERC APPROVED 800A METER / MAIN COMMERCIAL METERED SWITCHBOARD MEP, WHICH REPLACES EXISTING SWITCHBOARD MEP. REFER TO PICTURE REFERENCE ON DETAIL 9-E1.2A FOR PICTORAL REFERENCE OF THE EXISTING SWITCHBOARD MEP. NEW SWITCHBOARD SHALL BE 800A, 208Y/120V, 3Ø, 4W, N1, 65KAIC, WITH THREE TENANT UTILITY METER SOCKETS, & THREE CORRESPONDING TENANT MAIN BREAKERS AS IS REFLECTED ON SHEET E0.1 SLD, & ON SHEET E1.2A DETAILS. EC TO PROCURE GEAR SHOP DRAWINGS FROM SWITCHBOARD VENDOR, & SUBMIT TO PG&E & THE CITY OF SAN JOSE FOR APPROVAL ALONG WITH THIS DESIGN, PRIOR TO THE PURCHASE OF THE SWITCHBOARD. SEE SLD ON SHEET E0.1 FOR WIRING / GROUNDING REQUIREMENTS. REFER TO SHEET NOTE 40 BELOW FOR SECURING THE SERVICE TO THE EX FLOOR SLAB. SEE ALSO GENERAL NOTE 20 ON SHEET E2.1 FOR ADDITIONAL REQUIREMENTS. [40] EQUIPMENT SHALL BE SECURED TO EXISTING EQUIPMENT PAD & EXISTING EXTERIOR WALL PER THE EQUIPMENT SPECIFICATIONS, & THE STRUCTURAL DRAWINGS IF APPLICABLE. THE EQUIPMENT WEIGHS >400 LBS. THUS, EQUIPMENT IS NOT REQUIRED TO HAVE SEISMIC ANCHORING PER CBC / UBC. REFER TO DETAIL 4-E1.2 ON SHEET E1.2 FOR ALL EQUIPMENT MOUNTING REQUIREMENTS. [41] EC SHALL HAVE NEW MEP TESTED & CERTIFIED BY AN APPROVED TESTING AGENCY, I.E POWER SYSTEMS INC. THE TESTING SHALL INCLUDE MAIN BREAKER TESTING & GROUND RESISTANCE TESTING. A COPY OF THE TESTING REPORT TO BE SUBMITTED TO THE CUSTOMER. A CERTIFICATION STICKER SHALL BE SECURED TO SWITCHBOARD ADJACENT TO THE MEP MAIN BREAKER. [42] PROVIDE (2) 2' EMT EMPTY CONDUIT STUBS IN CEILING SPACE FROM NEW MSB1 FOR FUTURE TENANT PANEL. PANEL & WIRING TO BE PROVIDED UNDER A FUTURE ELECTRICAL PERMIT SUBMITTAL. REFER TO SLD ON SHEET E0.1 FOR ADDITIONAL REQUIREMENTS. EC TO VIF EXISTING FIELD CONDITIONS FOR CONDUIT INSTALLATION REQ'S, & VIF WITH THE GC CONDUIT ROUTING LOCATIONS. [43] PROVIDE (1) 2' EMT EMPTY CONDUIT STUB IN CEILING SPACE FROM NEW MSB1 FOR FUTURE TENANT PANEL. PANEL & WIRING TO BE PROVIDED UNDER A FUTURE ELECTRICAL PERMIT SUBMITTAL. REFER TO SLD ON SHEET E0.1 FOR ADDITIONAL REQUIREMENTS. EC TO VIF EXISTING FIELD CONDITIONS FOR CONDUIT INSTALLATION REQ'S, & VIF WITH THE GC CONDUIT ROUTING LOCATIONS. [44] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO FUTURE SIGN, WHICH IS F&IBO. SIGN TO BE CONTROLLED VIA TC1 AS REFLECTED IN DETAIL 3 SHEET ON E1.2A. COORDINATE SIGN J-BOX LOCATION & ALL REQUIREMENTS WITH THE GC. [45] POS RECEPTACLE LOCATED UNDER COUNTER IN CABINET. VIF LOCATION & ALL REQ'S WITH THE GC. [46] PROVIDE 208V POWER & NON-FUSED DISCONNECT SWITCH FOR FLEXIBLE CONNECTION TO NEW WATER HEATER. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & PC. [47] EC TO VIF WITH THE GC & TENANT ALL EQUIPMENT POWER REQ'S & LOCATIONS PRIOR TO INSTALLATIONS. [48] PROVIDE ENLIGHTED PC.01.20 PLUG CONTROLLER FOR CONTROL OF RECEPTACLES IN THIS ROOM IN THE CEILING CAVITY, VIF. REFER TO APPLICABLE DETAILS ON THIS SHEET FOR WIRING DIAGRAMS. INSTALLATION, WIRING, & PROGRAMMING SHALL COMPLY WITH THE 2019 CA ENERGY CODE, SECTION 130.5 FOR LOAD CONTROLLED RECEPTACLES. THE REQ'D 120V INPUT POWER FOR THE CONTROLLER TO BE PROCURED FROM THE RECEPTACLES CIRCUIT IN THIS ROOM. [49] PROVIDE P&S 26352CHW (OR =) SPLIT WIRED CONTROLLED RECEPTACLE. RECEPTACLE CIRCUIT FOR THIS ROOM TO BE WIRED TO THE ENLIGHTED PLUG CONTROLLER LOCATED ABOVE / IN THE CEILING. REFER TO APPLICABLE DETAILS THIS SHEET FOR WIRING DIAGRAMS. INSTALLATION & WIRING SHALL COMPLY WITH THE 2019 CA ENERGY CODE, SECTION 130.5 FOR LOAD CONTROLLED RECEPTACLES. TOP HALF OF THE RECEPTACLE SHALL BE LABELED AS A CONTROLLED RECEPTACLE PER THE CA 2019 ENERGY CODE . [50] REFER TO ENLIGHTED DETAILS THIS SHEET, & ENLIGHTED SUBMITTAL PACKAGE FOR ADDITIONAL LIGHTING CONTROL REQ'S, & LIGHTING CONTROL SEQUENCE OF OPERATIONS & PROGRAMMING, FOR THIS ROOM. ALL LIGHTING & CONTROL INSTALLATIONS TO COMPLY WITH THE 2019 CA ENERGY CODE. ALL NEW LIGHTING IN THIS ROOM TO BE FED FROM EX LTG CKT FROM PREVIOUS CONFIGURATION. [51] PROVIDE REFLECTED PRINTER RECEPTACLE AT THE END OF THE FURNITURE CUBICLES. REFER TO FURNITURE CONTRACTOR CUBICLE DRAWINGS FOR ADDITIONAL REQ'S & INSTALLATION METHODS. [52] PROVIDE REFLECTED RECEPTACLE & DATA OUTLET @ 66" AFF FOR TV MONITOR. VIF ALL REQ'S WITH GC. [53] PROVIDE CONNECTRAC SERIES OVER FLOOR RACEWAY AS REFLECTED. INSTALLATIONS SHALL COMPLY WITH NEC 380. VIF CONNECTRAC LOCATIONS & ALL REQUIREMENTS WITH THE GC / CUSTOMER. REFER TO CONNECTRAC DETAIL SHEETS ON SHEET E1.2A, DETAIL 8 FOR ADDITIONAL REQUIREMENTS. [54] PROVIDE (N)CLASS 3000 SERIES EMON CUSTOMER KWH METER, #208100C KIT, VIF. METER SHALL BE LOCATED ADJACENT NEW PANEL LD. COORDINATE REQUIREMENTS, LOCATION & PROGRAMMING WITH THE GC & THE TENANT. METER TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS & APPLICABLE ARTICLES OF THE NEC. REFER TO SLD ON SHEET E0.1 FOR ADDITIONAL REQUIREMENTS. [55] PROVIDE 20A, 120V 4PLEX RECEPTACLE @ 18" AFF FOR LAB 121 NEW RACK EQUIPMENT. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC PRIOR TO INSTALLATION OF SAME. [56] PROVIDE BUILDING STANDARD CABLOFIL CF 105-150 CABLE TRAY @ 96" AFF TO BOTTOM AFF, VIF. SECURE CABLE TRAY TO EXISTING WALL WITH CABLOFIL FASU 100 WALL BRACKETS ON 60" CENTERS. ALL CABLE TRAY INSTALLATIONS TO COMPLY WITH NEC ART. 392 & THE MANUFACTURER'S SPECIFICATIONS. SEE DETAILS 7, 8, & 9 ON SHEET E1.2A FOR CABLE TRAY SPECIFICATIONS & INSTALLATION REQUIREMENTS. VIF WITH GC & THE CUSTOMER CABLE TRAY LOCATIONS & ALL REQ'S. ALL CABLE TRAY TO BE BONDED TOGETHER & TO EX BLDG STEEL VIA #4 THHN CU & LUGS FROM CABLE TRAY TO EX BLDG STEEL OR EQUILVALENT GROUND SOURCE, VIF. ALL CABLE TRAY CABLING IS F&IBO. EC SHALL FIELD COORDINATE CABLE TRAY INSTALLATIONS & LOCATIONS WITH ALL OTHER TRADES. THE CABLE TRAY IS SELF CONTAINED IN THIS LAB & DOES NOT PENETRATE THE SIDE WALLS, THUS FIRESTOPPING IS NOT REQ'D. [57] REFLECTED CONDUIT PATH IS REFLECTED FOR CONCEPTUAL REFERENCE ONLY. EC TO VIF ACTUAL CONDUIT PATH IN CEILING WITH ALL EXISTING CONDITIONS IN THE CEILING, & ADJUST ACCORDINGLY. [58] PROVIDE BUILDING STANDARD G4000 WIREMOLD ON WALL @ 24" AFF TO TOP, VIF. ALL WIREMOLD INSTALLATIONS SHALL COMPLY WITH NEC 386. THE SUM OF THE CROSS SECTIONAL AREA OF ALL CONTAINED CONDUCTORS SHALL NOT EXCEED 20% OF INTERIOR CROSS SECTIONAL AREA OF THE WIREMOLD. FURTHERMORE, THERE SHALL NOT BE MORE THAN 30 CURRENT CARRYING CONDUCTORS AT ANY POINT IN THE WIREMOLD. CONDUITS FEEDING WIREMOLD SHALL ALSO COMPLY WITH ALL CONDUCTOR DERATING REQUIREMENTS PER NEC 310-15. VIF LOCATIONS & ALL REQUIREMENTS WITH THE GC & AEROHIVE. REFER TO DETAIL 7-E1.2A ON SHEET E1.2A FOR INSTALLATION REQUIREMENTS. [59] PROVIDE BUILDING STANDARD G4000 WIREMOLD SUSPENDED FROM CLG STRUCTURE, VIF. WIREMOLD INSTALLATIONS SHALL COMPLY WITH NEC 386. THE SUM OF THE CROSS SECTIONAL AREA OF ALL CONTAINED CONDUCTORS SHALL NOT EXCEED 20% OF INTERIOR CROSS SECTIONAL AREA OF THE WIREMOLD. FURTHERMORE, THERE SHALL NOT BE MORE THAN 30 CURRENT CARRYING CONDUCTORS AT ANY POINT IN THE WIREMOLD. CONDUITS FEEDING WIREMOLD SHALL ALSO COMPLY WITH ALL CONDUCTOR DERATING REQUIREMENTS PER NEC 310-15. VIF LOCATIONS & ALL REQUIREMENTS WITH THE GC & AEROHIVE. REFER TO DETAIL 8-E1.2A ON SHEET E1.2A FOR INSTALLATION REQUIREMENTS. F3 0 F33 F32 F31 FEEDER / BRANCH CKT SCHEDULE. CONDUCTORS TO BE CU, UNO. USE SCHEDULE AS APPLICABLE. CONDUCTORS QT Y F29 F13 F15 F17 F18 F19 F20 F21 F16 F14 F24 F25 F26 F28 F27 F23 F22 F11 CONDUIT PHASE QTY SIZETYPE TAG QTY SIZE F6 F4 F1 F2 F3 F5 F7 F8 F9 F10 F1 2 NEUTRAL GROUND QTY SIZE SIZE 1. ALL CONDUCTORS SHALL BE TYPE THHN / TWHN 90° 600V COPPER FOR ABOVE GRADE, & THWN-2 90° 600V COPPER FOR BELOW GRADE/WET LOCATIONS, UNO. 2. REFLECTED CONDUCTORS HAVE NOT BEEN DE-RATED FOR NON-STANDARD AMBIENT TEMPERATURES & ARE BASED ON 30°C AMBIENT. 3. REFLECTED CONDUIT SIZES ARE MINIMUM SIZES PER NEC CHAPTER 9 (CONDUIT CONDUCTOR CHARTS). 4. ALL CONDUCTOR SIZING INCLUDES VOLTAGE DROP & DERATING CALCS, & SHALL COMPLY WITH NEC ART. 310. 5. SHOULD UG PVC CONDUIT BE SUBSTITUTED FOR EMT CONDUITS, PROVIDE EGC SIZED PER NEC TABLE 250.122, & INCREASE C. SIZE AS REQ'D FOR COMPLIANCE. 3#600-H,2#600-N,1#250-EGC IN EA. 3#350-H,1#350-N,1#3/0-EGC IN EA. 3#500-H, 1#2-EGCPVC/EMT 3 1#10-H, 1#10-N, 1#10-EGCPVC/EMT 3/4 EMPTY CONDUIT WITH PULL STRING 2#10-H, 1#10-N, 1#10-EGCPVC/EMT 3/41 PVC/EMT 3/4 1#10-H, 1#10-N, 1#10-EGC 3#10-H, 1#10-EGC EMT/FLEX 4 3 4 6 3 3EMT/FLEX 43 2 3 1 3 13 1/0 1/0 3 3 2 3 3 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 500 300 3 3 3 3 350 3 EMT/FLEX EMT/FLEX EMT/FLEX WIREWAY EMT/FLEX 3/0EMT/FLEX 4/0EMT/FLEX 2 1 1 1 1 1 1 1 1 1 2 1 1 2 6sets 4 2 3 2 1/2 12x12 2-1/2 2-1/2 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/4 350 1/21 EMT/FLEX 10 EMT/FLEX 10 12 10 12 2 2 1 3 103 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 10 4 10 6 10 5 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 3 3/4 1 1 1 1 1 1 1 1 1 3/4 1/2 1/2 1/2 1/2 3/4 3/4 6 3 1 EMT/FLEX 1 0 2 0 6-6IG 1 1 10 8 1 8 1 8 61 1 6 1 6 1 8 1 4 4 61 0 41 20 1/0 1/0 1 1 2 2 0 1 0 1/0 1 1 1 1 6 3 1 3/0 500 300 1 0 1 350 0 3/0 4/0 1-0 350 10 1 10 1 1 1 1 1 10 12 10 12 10 10 12 10 12 10 1 1 1 1 1 1 10 1 1 10 10 10 2 10 10 2 2 2 1 106 0 CR 5 HP, 240V, 1%%C MANUAL MOTOR STARTER EATON B230AN OR =, FOR HVAC EQUIPMENT DATA ALL DEVICE TYPES & COLOR, & WALL PLATE FINISH & COLOR, SHALL BE WHITE PLASTIC, UNO. REFER ALSO TO SHEET E0.1 SYMBOL LIST & GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. 5-15R RECEPTACLES MAY BE SUBSTITUTED FOR 5-20R CONVENIENCE RECEPTACLES, UNO. NEMA#/DEVICE P D Sms S mts Sa L5-30R L5-30R LOCATION AS NOTED, UON RECEPTACLE & DEVICE LEGEND. USE THIS SCHEDULE AS APPLICABLE. DEVICE SYMBOL DEVICE NEMA # ADDITIONAL NOTES Sk07 AV 5-20R(VIF) WALL @ 44" POKE-THRU W/1G RING CR 4SQ JB W/DATA SEE SHEET NOTE 11 SEE SHEET NOTE 8 POWERPOLE WALL WALL 20A-2P 30A-3P 600V 600V 120/277V 20A-1P 5-20R(VIF) W/DATA 2G DATA 2G DATA PER E2.1 WALL WALL WALL MANUAL MOTOR SW TOGGLE SWITCH SQD TYPE KO2 MANUAL MOTOR SW SQD TYPE KO6 SEE SHEET NOTE ** CLG DROP 4SQ BOX & 3/4" C. 2G 4SQ BOX & 1"C SEE SHEET NOTE 18 (2)5-20R FLUSH CLG. FLUSH CLG. L5-30R (2)5-20R 5-20R L5-30R W/DATA W/2G DATA 5-20R (2)5-20R CLG DROP WALL CEILING FLOORBOX SEE SHEET NOTE 18 SEE SHEET NOTE 7 NEMA# PER DEVICE NEMA# PER DEVICE 4PLEX W/DATA NA NA WALL/WM 5-20R (2)5-20R 5-20R GFI W/2G DATA 5-20R DUPLEX 4PLEX DUPLEX DUPLEX W/DATA WALL/WM WALL/WM WALL/WM WALL/WM 1RB1B-33JNEW BF JB "T1" (E)XFM 2EX-"1LEB" EX - " 1 R B 1 C . 1 & 2 " EX-"1LB1" EX-"1REB" EX-"1RB1" EX - " 1 R B 1 B " EX - " 1 R B 1 A " 3 CR 11 (EX)1RB1B-33,35,37,39,41(VIF)J EX CEILING JB31 1RB1B-35JNEW BF JB3 F1 F1 (N)1RB1B-37 +18",VIF (N)DATA F1 25 NOTE: ALL RECEPTACLES IN ROOM A141 TO HAVE DEDICATED NEUTRAL CONDUCTORS PER APPLE 07.31.18 ELECTRICAL DESIGN BUILD GUIDE LINES. 161718 D.7 D.5 D.3 D.8 D.9 E D C A116 ELECTRICAL A138 A136 A134 A133 TELECOM MDF/MPOE A142 OFFICE A141 OFFICEROOM B114 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E2.1 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 RO O M A 1 4 1 P O W E R P L A N , S C H E D U L E S 4 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:25:21 -07'00' Arnold Hom 06/23/21 1 LTG & POWER SHEET NOTES AS APPLICABLE [ ] (SEE ALSO GENERAL NOTES ON E0.1) (1)NOT CONTROLLED DUPLEX RECEP(1)CONTROLLED DUPLEX RECEPTACLE CR CR CR CL GCS1 CR ALL DEVICE TYPES & COLOR, & WALL PLATE FINISH & COLOR, TO BE VIF WITH GC. ALL DEVICES & CONFIGURATIONS SHALL COMPLY WITH THE 2019 CA ENERGY CODE & CA ELECTRIC CODE. ENLIGHTED DEVICES SHALL BE INSTALLED & WIRED PER THE ENLIGHTED DEVICE SPECIFICATIONS, VIF. LOCATION AS NOTED, UON ENLIGHTED (U.N.O.) DEVICE LEGEND. ALL ENLIGHTED CONTROLS ARE WIRELESS, U.N.O. DEVICE SYMBOL ENLIGHTED CAT # & DEVICE TYPE SW I T C H WR C 1 CL GCS3 SW I T C H WR C 2 CL GCS2 CL GPOE CL GSCF CL GPLC CL GGW CR NCR GW-2-01 GATEWAY CONTROLLERCEILING PC-01-20 PLUG LOAD CONTROLCEILING WALL WS-2-00 WALL CONTROL WALL NOT USED CEILING SU-4E-01 COMPACT SENSOR CBL-3-7F COMPACT SENSOR CU-3E-1R CONTROL UNIT LWP-SW-PoE-8-8, PoE SWITCH SU-4E-01 COMP SENSOR (FACTORY) P&S 26352CHW SPLIT-WIRED CR (2)P&S 26352CHW SPLIT-WIRED CR P&S 26352CHW SPLIT-WIRED CR WM OFR FURNITURE CONNECTION CEILING CEILING CEILING CEILING WALL WALL FLOOR FLOOR WALL [1] SEE SINGLE LINE DIAGRAM ON SHEET E0.1, & DETAILS ON SHEET E1.2A, FOR ALL APPLICABLE WIRING &/OR GROUNDING REQUIREMENTS. SEE DETAIL 4 ON SHEET E1.2A FOR SEISMIC ANCHORING REQUIREMENTS ON ALL ELECTRICAL EQUIPMENT EXCEEDING 400 LBS. IN WEIGHT. [2] ALL POWER / DEVICES / LIGHTING IN THIS ROOM ARE EXISTING, SHALL REMAIN AS IS, & ARE NIC, UNO. [3] PROVIDE CEILING J-BOX WITH REFLECTED CIRCUITS FOR FURNITURE POWER POLE, PP IS F&IBO, & WIRED BY THE EC. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [4] PROVIDE FLUSH WALL J-BOX FOR POWER & DATA @18" AFF FOR CUBICLE BASE FEED. BASE FEED IS F&IBO, WIRED BY THE EC. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [5] PROVIDE NEW BLDG STANDARD 225A, 208Y/120V, 3Ø, 4W, N1, 100% N, 10 KAIC, 42 CKT, MCB SURFACE MOUNT PANELBOARD. SEE SLD ON SHEET E2.1 & DETAIL 1/2 ON SHEET E1.2A FOR WIRING / GROUNDING REQUIREMENTS. COORDINATE LOCATION WITH GC & CUSTOMER. EC TO VIF CONDUIT ROUTING PATH FOR NEW PANEL FROM SOURCE, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [6] PROVIDE NEW BLDG STANDARD 225A, 480Y/277V, 3Ø, 4W, N1, 25 KAIC, 30 CKT, MLO, SURFACE MOUNT PANELBOARD. SEE SLD ON SHEET E2.1, & DETAIL 2 ON SHEET E1.2A FOR WIRING / GROUNDING REQUIREMENTS. EC TO VIF CONDUIT ROUTING PATH FOR NEW PANEL FROM SOURCE, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [7] PROVIDE BLDG. STANDARD OR = WALKER COMBO FLOOR BOX 880CS3-1 W/827B BRASS COVER PLATE. PROVIDE 3/4" PVC SCH 40 POWER CONDUIT & 1" SCH 40 PVC DATA CONDUIT FROM BOX TO NEAREST DEVICE AS REFLECTED. ALL SLAB ON GRADE SAW CUTTING & PATCHING F&I BY GC. EC TO VIF THE SLAB IS FREE OF OBSTRUCTIONS PRIOR TO ALL SAW CUTTING. COORDINATE BOX LOCATION / REQ'S WITH GC. INSTALLATION SHALL COMPLY WITH THE NEC & MANUFACTURERS SPECS. SEE ALSO DETAIL ON SHEET E1.2A COORDINATE POWER & DATA CONNECTION TO FURNITURE PANELS WITH GC. [8] PROVIDE WALKER POKE THROUGH FITTING RC700-A &/OR RC700-6A, OR APPROVED =. EC SHALL PROVIDE FLOOR CORE FOR THE FITTING PER THE MANUFACTURER'S SPECIFICATIONS. EC SHALL VIF ANY OBSTRUCTIONS IN THE FLOOR SLAB PRIOR TO CORING. ALL CONDUIT & WIRING SHALL BE INSTALLED IN TENANT SPACE BELOW, & SHALL TERMINATE INTO THE ADJACENT WIRING DEVICE AS REFLECTED. COORDINATE LOCATION/ALL REQUIREMENTS WITH THE GC & CUSTOMER. SEE DETAIL ON SHEET E1.2A FOR PICTORAL REFERENCE ONLY. PROVIDE DEVICES PER THE DRAWINGS. REFLECTED POKE THRU MAY BE EX FROM PREVIOUS FURNITURE & RELOCATED TO THIS LOCATION, VIF. [9] PROVIDE 120V POWER FOR FRACTIONAL HP CEILING MOUNT EXHAUST FAN, WHICH IS F&IBO, & WIRED BY THE EC. FAN SHALL BE CONTROLLED BY LIGHT SWITCH AS REFLECTED ON SHEET E3.1 & DETAIL 6 ON SHEET E1.2A. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC / MC. [10] PROVIDE 208V POWER IN WALL J-BOX @ 48" AFF(VIF) FOR FLEXIBLE CONNECTION TO NEW WATER HEATER. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / PC. [11] PROVIDE 120V POWER (IF APPLICABLE) IN CEILING/WALL J-BOX FOR CONNECTION TO NEW CARD READER CARD ACCESS SYSTEM. ALSO PROVIDE 1-GANG FLUSH BOX @ 44" AFF(VIF) WITH 3/4" C. FROM BOX TO 6" ABOVE CEILING. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [12] PROVIDE 120V IN CEILING 4SQ. J-BOX FOR CONNECTION TO FIRE-SMOKE DAMPERS. COORDINATE LOCATION & ALL REQUIREMENTS WITH MC / GC & THE MECHANICAL DRAWINGS. [13] PROVIDE 120V IN CEILING 4SQ. J-BOX FOR CONNECTION TO FIRE ALARM SYSTEM EQUIPMENT. COOR- DINATE LOCATION & ALL REQUIREMENTS WITH LIFE SAFETY CONTRACTOR & THE GC. [14] PROVIDE 120V POWER IN CEILING J-BOX & UP/DOWN LV WALL SWITCH CONTROL FOR CONNECTION TO NEW PROJECTOR SCREEN. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC & CUSTOMER. [15] PROVIDE 4PLEX RECEPTACLE FLUSH IN CEILING FOR CEILING PROJECTOR. COORDINATE LOCATION & ALL REQUIREMENTS WITH GC / CUSTOMER. LABEL DEVICES "CEILING PROJECTOR". [16] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO SECURITY SYSTEM CAMERA. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [17] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO 12V DOOR CONTACTS FOR SECURITY SYSTEM. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC / CUSTOMER. [18] PROVIDE REFLECTED CEILING CORD DROP AS REFLECTED. SEE APPLICABLE SHEET E1.2A DETAIL FOR INSTALLATION REQUIREMENTS. COORDINATE LOCATION & REQUIREMENTS WITH GC & CUSTOMER. [19] PROVIDE 120V POWER IN CEILING J-BOX FOR CONNECTION TO ELECTRIFIED MECHOSHADE. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [20] PROVIDE GFI RECEPTACLE WITHIN 25' OF MECHANICAL EQUIPMENT PER NEC ARTICLE 210-63. EXTEND SAME 120V TO ANY APPLICABLE HVAC ACCESSORIES, IE CONDENSATE PUMP & SMOKE DETECTOR. [21] PROVIDE WIREMOLD 30TP-2V OR 30TP-4V OR 25DTP-412(VIF) POWER POLE WITH DEVICES AS REFLECTED ON THE SHEET E2.1. REFER TO DETAIL 7 ON SHEET E1.2A FOR PICTORAL REFERENCE. COORDINATE LOCATION & ALL REQUIREMENTS WITH THE GC & CUSTOMER. [22] NOT USED. [23] PROVIDE 120V SHOW WINDOW RECEPTACLE FLUSH IN CEILING EVERY 12' PER NEC 210.62., 220.14. RECEPTACLES SHALL BE CONTROLLED VIA TC1 AS REFLECTED IN DETAIL 3 SHEET ON E1.2A. [24] ALL ELECTRICAL EQUIPMENT IN THIS ROOM SHALL COMPLY WITH CLEARANCES PER NEC 110.26, VIF. [25] EC TO VIF ALL DEVICE LOCATIONS & REQUIREMENTS IN THIS ROOM WITH GC PRIOR TO INSTALLATIONS. [26] EXISTING SERVER ROOM IS NOT CLASSIFIED & CONSTRUCTED AS AN INFORMATION TECHNOLOGY EQUIPMENT ROOM. THUS, COMPLIANCE WITH NEC / CEC ARTICLE 645 IS NOT REQUIRED. [27] ALL SERVER / IDF ROOM DATA WIRING, IF APPLICABLE, IS F&IBO. EC SHALL VIF WITH GC & CUSTOMER FOR ALL CONDUIT REQUIREMENTS FOR DATA LADDER RACK REQUIREMENTS AS APPLICABLE. [28] PROVIDE 208V, 3Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. [29] PROVIDE 480V, 3Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE GC. [30] PROVIDE 120V, 1Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. FAN TO BE CONTROLLED VIA THE RESTROOM LIGHTING CONTROL, VIF. [31] REFLECTED CIRCUITS (VIF) ARE EXISTING IN CEILING JB FROM PREVIOUS LAYOUT CONFIGURATION. EC SHALL EXTEND EXISTING CIRCUITRY TO NEW &/OR RELOCATED RECEPTACLES AS REFLECTED. [32] PROVIDE MISCELLANEOUS ELECTRICAL DEMO IN THIS ROOM, REFER TO ARCHITECTURAL DEMO PLAN. [33] PROVIDE 480V, 3Ø POWER & DISCONNECT SWITCH FOR CONNECTION TO ROOF MOUNT HVAC EQUIP. COORDINATE LOCATION & ALL REQUIREMENTS, INCLUDING CONTROL REQUIREMENTS, WITH THE MC. [34] PROVIDE 75 kVA, 480V Δ TO 208Y/120V, 3Ø, N1, XFMR AT REFLECTED LOCATION. SEE SLD ON E0.1 & DETAIL 2 ON SHEET E1.2A FOR WIRING & GROUNDING REQUIREMENTS. VIF XFMR LOCATION WITH GC. SEE DETAIL 4 ON SHEET E1.2A, & STRUCTURAL DRAWING AS APPLICABLE FOR ANCHORING XFMR TO EX FLOOR SLAB. UPON PROJECT COMPLETION & WITH XFMR UNDER FULL LOAD, VIF XFMR SECONDARY OUTPUT VOLTAGE, & ADJUST TAPS AS REQ'D TO MAINTAIN 208V (L-L) & 120V (L-G). EC TO VIF CONDUIT ROUTING PATH FOR NEW XFMR FROM SOURCE, & PROVIDE JB'S AS REQUIRED FOR NEC COMPLIANCE. [35] PROVIDE NEW BUILDING STANDARD (IEM OR APPROVED =) 2000A, 208Y/120V, 3Ø, 4W, N1, 200% N, 50 KAIC, 100%, MCB, SURFACE DISTRIBUTION. PANEL. SEE SLD ON SHEET E2.3 FOR WIRING, GROUNDING & APPLICABLE INSTALLATION REQUIREMENTS. COORDINATE LOCATION WITH THE GC & CUSTOMER. [36]PROVIDE NEW BUILDING STANDARD (IEM OR APPROVED =) 1200A, 480Y/277V, 3Ø, 4W, N1, 50 KAIC, 80%, MLO, SURFACE MOUNT DISTRIBUTION PANEL. SEE SLD ON SHEET E2.3 FOR WIRING, GROUNDING & APPLICABLE INSTALLATION REQUIREMENTS. COORDINATE LOCATION WITH THE GC & / OR MITAC. EC TO VIF CONDUIT ROUTING PATH FOR (N)DPH1 FROM MSB, & PROVIDE JB'S AS REQ'D FOR NEC COMPLIANCE. [37] PROVIDE 4"x36" ABOVE GRADE GRS CONCRETE FILLED BOLLARD WITH CAP AT REFLECTED LOCATIONS. BOLLARDS SHALL BE PAINTED CAUTION YELLOW & SHALL BE SECURED TO FLOOR VIA (4)5/8"x 4" WEDGE ANCHORS. COORDINATE LOCATIONS/ALL REQ'S WITH GC, & STRUCTURAL DRAWINGS IF APPLICABLE. [38] PROVIDE NEW EATON EUSERC APPROVED 800A METER / MAIN COMMERCIAL METERED SWITCHBOARD MEP, WHICH REPLACES EXISTING SWITCHBOARD MEP. REFER TO PICTURE REFERENCE ON DETAIL 9-E1.2A FOR PICTORAL REFERENCE OF THE EXISTING SWITCHBOARD MEP. NEW SWITCHBOARD SHALL BE 800A, 208Y/120V, 3Ø, 4W, N1, 65KAIC, WITH THREE TENANT UTILITY METER SOCKETS, & THREE CORRESPONDING TENANT MAIN BREAKERS AS IS REFLECTED ON SHEET E0.1 SLD, & ON SHEET E1.2A DETAILS. EC TO PROCURE GEAR SHOP DRAWINGS FROM SWITCHBOARD VENDOR, & SUBMIT TO PG&E & THE CITY OF SAN JOSE FOR APPROVAL ALONG WITH THIS DESIGN, PRIOR TO THE PURCHASE OF THE SWITCHBOARD. SEE SLD ON SHEET E0.1 FOR WIRING / GROUNDING REQUIREMENTS. REFER TO SHEET NOTE 40 BELOW FOR SECURING THE SERVICE TO THE EX FLOOR SLAB. SEE ALSO GENERAL NOTE 20 ON SHEET E2.1 FOR ADDITIONAL REQUIREMENTS. [39] EQUIPMENT SHALL BE SECURED TO EXISTING EQUIPMENT PAD & EXISTING EXTERIOR WALL PER THE EQUIPMENT SPECIFICATIONS, & THE STRUCTURAL DRAWINGS IF APPLICABLE. THE EQUIPMENT WEIGHS >400 LBS. THUS, EQUIPMENT IS NOT REQUIRED TO HAVE SEISMIC ANCHORING PER CBC / UBC. REFER TO DETAIL 4-E1.2 ON SHEET E1.2 FOR ALL EQUIPMENT MOUNTING REQUIREMENTS. [40] EC SHALL HAVE NEW MEP TESTED & CERTIFIED BY AN APPROVED TESTING AGENCY, I.E POWER SYSTEMS INC. THE TESTING SHALL INCLUDE MAIN BREAKER TESTING & GROUND RESISTANCE TESTING. A COPY OF THE TESTING REPORT TO BE SUBMITTED TO THE CUSTOMER. A CERTIFICATION STICKER SHALL BE SECURED TO SWITCHBOARD ADJACENT TO THE MEP MAIN BREAKER. [41] PROVIDE NEW TITLE 24 APPROVED ELECTRONIC TIME CLOCK TC1 ADJACENT TO NEW PANEL L** FOR CONTROL OF FUTURE SHOW WINDOW RECEPTACLES, & FOR FUTURE SIGN. TC1 SHALL BE INTERMATIC ET80215C SURFACE MOUNT, OR APPROVED =. REFER TO DETAIL 3-E1.2 ON SHEET E1.2A FOR ALL WIRING & INSTALLATION REQUIREMENT'S. [42] PROVIDE ENLIGHTED PC.01.20 PLUG CONTROLLER FOR CONTROL OF RECEPTACLES IN THIS ROOM IN THE CEILING CAVITY, VIF. REFER TO APPLICABLE DETAILS ON THIS SHEET FOR WIRING DIAGRAMS. INSTALLATION, WIRING, & PROGRAMMING SHALL COMPLY WITH THE 2019 CA ENERGY CODE, SECTION 130.5 FOR LOAD CONTROLLED RECEPTACLES. THE REQ'D 120V INPUT POWER FOR THE CONTROLLER TO BE PROCURED FROM THE RECEPTACLES CIRCUIT IN THIS ROOM. [43] PROVIDE P&S 26352CHW (OR =) SPLIT WIRED CONTROLLED RECEPTACLE. RECEPTACLE CIRCUIT FOR THIS ROOM TO BE WIRED TO THE ENLIGHTED PLUG CONTROLLER LOCATED ABOVE / IN THE CEILING. REFER TO APPLICABLE DETAILS THIS SHEET FOR WIRING DIAGRAMS. INSTALLATION & WIRING SHALL COMPLY WITH THE 2019 CA ENERGY CODE, SECTION 130.5 FOR LOAD CONTROLLED RECEPTACLES. TOP HALF OF RECEPTACLE TO BE LABELED AS A CONTROLLED RECEP PER THE CA 2019 ENERGY CODE. [44] FIXTURE SHALL BE WIRED AS A NIGHT LIGHT / EM FIXTURE WITH (E) UNSWITCHED LIGHTING CIRCUIT AS REFLECTED (SAME CIRCUIT AS NORMAL POWER). EM FIXTURE WIRING SHALL COMPLY WITH NEC ARTICLE 700.9 & 700.12. SEE ALSO GENERAL NOTE 67 & 80 ON SHEET E0.1. [45] NEW EXIT FIXTURE SHALL BE WIRED WITH (E) EM UN-SWITCHED LIGHTING CIRCUIT AS REFLECTED. EXIT FIXTURE WIRING TO COMPLY WITH NEC ARTICLE 700.9 & 700.12. SEE ALSO GENERAL NOTE 67 ON E0.1. [46] UNO, APPLICABLE LTG, EXIT / EM LTG, NIGHT LTG & SWITCHING IN THIS ROOM IS EXISTING & IS NIC. [47] PROVIDE NEW BLDG STANDARD LED EXIT FIXTURE WITH 90 MINUTE BATTERY AS REFLECTED. FIXTURE SHALL BE WIRED TO NEARBY NEW LIGHT FIXTURE CIRCUITRY AS REQ'D. SEE ALSO NOTE 45 ABOVE. [48] EXIT FIXTURE IS EX & TO REMAIN. VIF THE FIXTURE WORKS PROPERLY, & RECTIFY IF REQUIRED. [49] PROVIDE ENLIGHTED WS.2.00 WIRELESS WALL CONTROL, INCLUDING ALL REQ'D ACCESSORIES (VIF WITH ENLIGHTED), FOR CONTROL OF FIXTURES IN THIS ROOM / AREA. SEE DETAILS ON THIS SHEET FOR WIRING / INSTALLATION REQUIREMENTS. COORDINATE SWITCHING LOCATIONS WITH THE GC. [50] PROVIDE ENLIGHTED SU.4E.01 COMPACT WIRELESS OCCUPANCY CEILING SENSOR, INCLUDING ALL REQUIRED ACCESSORIES (VIF WITH ENLIGHTED), FOR AUTOMATIC CONTROL OF FIXTURES IN THIS ROOM / AREA. SEE DETAILS ON THIS SHEET FOR WIRING / INSTALLATION REQUIREMENTS. THIS CEILING SENSOR ALSO COMPLIES WITH ALL DAYLIT REQ'S PER THE 2019 ENERGY CODE SECTION 130.1. [51] PROVIDE ENLIGHTED SU.4E.01 COMPACT WIRELESS OCCUPANCY CEILING SENSOR, INCLUDING ALL REQUIRED ACCESSORIES (VIF WITH ENLIGHTED), FOR AUTOMATIC CONTROL OF FIXTURES IN THIS ROOM / AREA. SEE DETAILS ON THIS SHEET FOR WIRING / INSTALLATION REQUIREMENTS. THIS CEILING SENSOR ALSO COMPLIES WITH ALL DAYLIT REQUIREMENTS PER THE 2019 ENERGY CODE SECTION 130.1. SENSOR IS INTEGRAL (FACTORY INSTALLED INTO THE FIXTURE) WITH THE REFLECTED FIXTURE . [52] REFER TO ENLIGHTED DETAILS THIS SHEET, & ENLIGHTED SUBMITTAL PACKAGE FOR ADDITIONAL LIGHTING CONTROL REQ'S, & LIGHTING CONTROL SEQUENCE OF OPERATIONS & PROGRAMMING, FOR THIS ROOM. ALL LIGHTING & CONTROL INSTALLATIONS TO COMPLY WITH THE 2019 CA ENERGY CODE. ALL NEW LIGHTING IN THIS ROOM TO BE FED FROM EX LTG CKT FROM PREVIOUS CONFIGURATION. [53] PROVIDE ENLIGHTED GW.2.01 GATEWAY CONTROLLER, INCLUDING ALL REQ'D ACCESSORIES (VIF WITH ENLIGHTED), FOR CONNECTION OF WIRELESS DEVICES IN THIS SUITE. SEE DETAILS ON THIS SHEET FOR WIRING / INSTALLATION REQUIREMENTS. COORDINATE GATEWAY LOCATION WITH THE ENLIGHTED. [54] PROVIDE BUILDING STANDARD LED 2' x 2' GRID TROFFER FIXTURE AS REFLECTED WITH REQUIRED CONTROLS. THE NEW FIXTURE REPLACES THE EXISTING 2'x4' GRID FIXTURE & REDUCES WATTAGE BY 20W. PER 2019 CA ENERGY CODE SECTION 141.0.B.2.Ii, WATTAGE CALCS & COMPLIANCE IS NOT REQ'D. USE ENLIGHTED DETAILS AS APPLICABLE USE ENLIGHTED DETAILS AS APPLICABLE CR 5 HP, 240V, 1%%C MANUAL MOTOR STARTER EATON B230AN OR =, FOR HVAC EQUIPMENT DATA ALL DEVICE TYPES & COLOR, & WALL PLATE FINISH & COLOR, SHALL BE WHITE PLASTIC, UNO. REFER ALSO TO SHEET E0.1 SYMBOL LIST & GENERAL NOTES FOR ADDITIONAL REQUIREMENTS. 5-15R RECEPTACLES MAY BE SUBSTITUTED FOR 5-20R CONVENIENCE RECEPTACLES, UNO. NEMA#/DEVICE P D S ms S mts S a L5-30R L5-30R LOCATION AS NOTED, UON RECEPTACLE & DEVICE LEGEND. USE THIS SCHEDULE AS APPLICABLE. DEVICE SYMBOL DEVICE NEMA # ADDITIONAL NOTES S k07 AV 5-20R(VIF) WALL @ 44" POKE-THRU W/1G RING CR 4SQ JB W/DATA SEE SHEET NOTE 11 SEE SHEET NOTE 8 POWERPOLE WALL WALL 20A-2P 30A-3P 600V 600V 120/277V 20A-1P 5-20R(VIF) W/DATA 2G DATA 2G DATA PER E2.1 WALL WALL WALL MANUAL MOTOR SW TOGGLE SWITCH SQD TYPE KO2 MANUAL MOTOR SW SQD TYPE KO6 SEE SHEET NOTE ** CLG DROP 4SQ BOX & 3/4" C. 2G 4SQ BOX & 1"C SEE SHEET NOTE 18 (2)5-20R FLUSH CLG. FLUSH CLG. L5-30R (2)5-20R 5-20R L5-30R W/DATA W/2G DATA 5-20R (2)5-20R CLG DROP WALL CEILING FLOORBOX SEE SHEET NOTE 18 SEE SHEET NOTE 7 NEMA# PER DEVICE NEMA# PER DEVICE 4PLEX W/DATA NA NA WALL/WM 5-20R (2)5-20R 5-20R GFI W/2G DATA 5-20R DUPLEX 4PLEX DUPLEX DUPLEX W/DATA WALL/WM WALL/WM WALL/WM WALL/WM IL01.N ROOM A141 LIGHTING PLAN SCALE: 3/16" = 1' - 0"E3.1 1 LIGHTING SCOPE OF WORK FOR ROOM A141 THIS SHEET: PROVIDE NEW LED GRID TROFFER LIGHT FIXTURES, USING EXISTING LIGHTING CIRCUIT FROM PREVIOUS LIGHTING CONFIGURATION; PROVIDE NEW EXIT LIGHT FIXTURE IN ROOM B114 USING EXISTING EM EXIT CIRCUITRY FROM NEARBY EXISTING LIGHT FIXTURE IN THE ADJACENT CORRIDOR, VIF ALL EXISTING CIRCUITING CONDITIONS.......AS IS REFLECTED IN ABOVE LIGHTING PLAN. REFER TO SHEET E3.2 FOR THE CA 2019 ENERGY CODE SECTION 130.0 COMPLIANCE FORMS. REFER TO THE ARCHITECTURAL DRAWINGS AS APPLICABLE FOR DEMO SCOPE OF WORK. F3 0 F33 F32 F31 FEEDER / BRANCH CKT SCHEDULE. CONDUCTORS TO BE CU, UNO. USE SCHEDULE AS APPLICABLE. CONDUCTORS QT Y F29 F13 F15 F17 F18 F19 F20 F21 F16 F14 F24 F25 F26 F28 F27 F23 F22 F11 CONDUIT PHASE QTY SIZE TYPE TAG QTY SIZE F6 F4 F1 F2 F3 F5 F7 F8 F9 F10 F1 2 NEUTRAL GROUND QTY SIZE SIZE 1. ALL CONDUCTORS SHALL BE TYPE THHN / TWHN 90° 600V COPPER FOR ABOVE GRADE, & THWN-2 90° 600V COPPER FOR BELOW GRADE/WET LOCATIONS, UNO. 2. REFLECTED CONDUCTORS HAVE NOT BEEN DE-RATED FOR NON-STANDARD AMBIENT TEMPERATURES & ARE BASED ON 30°C AMBIENT. 3. REFLECTED CONDUIT SIZES ARE MINIMUM SIZES PER NEC CHAPTER 9 (CONDUIT CONDUCTOR CHARTS). 4. ALL CONDUCTOR SIZING INCLUDES VOLTAGE DROP & DERATING CALCS, & SHALL COMPLY WITH NEC ART. 310. 5. SHOULD UG PVC CONDUIT BE SUBSTITUTED FOR EMT CONDUITS, PROVIDE EGC SIZED PER NEC TABLE 250.122, & INCREASE C. SIZE AS REQ'D FOR COMPLIANCE. 3#600-H,2#600-N,1#250-EGC IN EA. 3#350-H,1#350-N,1#3/0-EGC IN EA. 3#500-H, 1#2-EGCPVC/EMT31 1#10-H, 1#10-N, 1#10-EGCPVC/EMT3/4 1 EMPTY CONDUIT WITH PULL STRING 2#10-H, 1#10-N, 1#10-EGCPVC/EMT3/41 PVC/EMT3/41 1#10-H, 1#10-N, 1#10-EGC 3#10-H, 1#10-EGC EMT/FLEX43 4 6 3 3EMT/FLEX 43 2 3 13 13 1/0 1/0 3 3 23 3 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 500 300 3 3 3 3 350 3 EMT/FLEX EMT/FLEX EMT/FLEX WIREWAY EMT/FLEX 3/0EMT/FLEX 4/0EMT/FLEX 2 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 2 6sets 4 2 3 2 1/2 12x12 2-1/2 2-1/2 1-1/4 1-1/2 1-1/2 1-1/2 1-1/4 350 1/21 EMT/FLEX 10EMT/FLEX 10 12 10 12 2 2 1 3 103 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 104 10 6 10 5 EMT/FLEX EMT/FLEX EMT/FLEX EMT/FLEX 3 3/4 1 1 1 1 1 1 1 1 1 1 1 1 3/4 1/2 1/2 1/2 1/2 3/4 3/4 6 3 1 1 EMT/FLEX 1 0 20 6-6IG 1 1 10 8 1 8 1 8 61 1 6 1 6 1 8 1 4 4 61 0 41 20 1/0 1/0 1 1 2 2 0 1 0 1/0 1 1 1 1 6 3 1 3/0 500 300 1 0 1 350 0 3/0 4/0 1-0 350 10 1 10 1 1 1 1 1 10 12 10 12 10 10 12 10 12 10 1 1 1 1 1 1 10 1 1 10 10 102 10 10 2 2 2 1 106 0 "T1" (E)XFM 2EX-"1LEB" EX - " 1 R B 1 C . 1 & 2 " EX-"1LB1" EX-"1REB" EX-"1RB1" EX - " 1 R B 1 B " EX - " 1 R B 1 A " "F2" 1LB1-12 wrc1.a 1LB1-12CS1 51 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 1LB1-12CS1 52 a WRC149 47 "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a "F2" 1LB1-12 wrc1.a 161718 D.7 D.5 D.3 D.8 D.9 E D C A116 ELECTRICAL A138 A136 A134 A133 TELECOM MDF/MPOE A142 OFFICE A141 OFFICE ROOM B114 USE ENLIGHTED DETAILS AS APPLICABLE 51 51 515151 51 51 51 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E3.1 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 RO O M A 1 4 1 L I G H T I N G P L A N , D E T A I L S , S C H E D U L E S 5 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:24:46 -07'00' Arnold Hom 06/23/21 04.12.21 CUSTOMER 90% MJ D.D. REVIEW - 04.14.21 ISSUED FOR MJ BUILDING PERMIT - TH E S E E L E C T R I C A L D E S I G N D R A W I N G S A R E GE N E R A T E D / C R E A T E D B Y T H E E L E C T R I C A L CO N T R A C T O R ( I N S T A L L E R ) O F R E C O R D Anthony J STATE OF CALIFORNIA REGISTERED ELECTRICAL CONTRACTOR T. MARSHALL ELECTRIC LIC. C10 #664428 EXP: 02.28.2023 Of Sheets Date Scale Drawn Sheet Job REV./COMM.BY 65 3 3 S I E R R A L A N E DU B L I N , C A 9 4 5 6 8 PH O N E : 9 2 5 . 7 3 4 . 9 9 9 9 LI C E N S E # 6 6 4 4 2 8 C 1 0 a s s o c i a t e s Lt d . a r s h a l l M T. E3.2 04.07.21 AS NOTED MJE MJE #21108 AP P L E I N C . - B U I L D I N G I L 0 1 . N E X I S T I N G B U I L D I N G & T E N A N T - N E W B A D G I N G O F F I C E R E N O V A T I O N S O N E I N F I N I T E L O O P , B U I L D I N G I L 0 1 . N - C U P E R T I N O , C A 9 5 0 1 4 C A 2 0 1 9 E N E R G Y C O D E S E C T I O N 1 3 0 . 0 C O M P L I A N C E 6 6 4/14/2021 Digitally signed by Anthony Jones DN: cn=Anthony Jones, o=T. Marshall Electric, email=ajones@ tmarshall.com, c=US Date: 2021.04.14 15:24:05 -07'00' Arnold Hom 06/23/21 GENERAL NOTES 1. ALL NEW DUCTWORK SHALL BE CONSTRUCTED, INSTALLED, SEALED, AND INSULATED AS REQUIRED BY CMC 2019 (OR NEWER), TITLE 24, AND LATEST SMACNA EDITION. 2. FURNISH ALL LABOR, MATERIALS, TRANSPORTATION, AND PERFORM ALL REQUIRED OPERATIONS TO PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM, IN ACCORDANCE WITH THE FULL INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS, PER STANDARD TRADE PRACTICES. 3. ALL LOCATIONS OF DUCTWORK AND EQUIPMENT ARE SHOWN DIAGRAMMATICALLY. ADHERE TO LOCATIONS AS CLOSELY AS POSSIBLE. VARY RUNS OR SHAPE OF DUCTWORK AS REQUIRED DUE TO SITE CONDITIONS, STRUCTURAL, OR OTHER OBSTACLES. 4. DUCT DIMENSIONS INDICATED ON PLAN ARE NET INTERIOR DIMENSIONS. PROVIDE MINIMUM LENGTHS OF SA AND RA DUCTS AS SCALED FROM DRAWINGS. 5. ALL EQUIPMENT SHALL BE INSTALLED WITH SUFFICIENT ACCESS TO CONTROLS, FILTERS, ELECTRIC MOTORS, ETC. DO NOT LOCATE THESE ITEMS IN GYP. BOARD CIELINGS. 6. ALL HVAC DUCTS AND PIPES SHALL BE SUPPORTED AND BRACED PER CMC 2019 ASCE-7-5, CHAPTER 13 AND ALL PIPING SHALL BE INSULATED PER T24 REQUIREMENTS. SCOPE OF WORK DRAWING INDEX OFFICE TI 1. RELOCATE EXISTING REGISTERS TO ACCOMMODATE NEW FLOOR PLAN. 2. NEW DUCT TO MATCH EXISTING WHERE REQUIRED. MAP KEY PROJECT NO. 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 SCALE: DRAWN BY: w w w . d a v i d w h i t n e y a r c h . c o m S a n J o s e , C A 9 5 1 2 6 3/ 3 0 / 2 0 2 1 9 : 0 0 : 0 5 P M M0.0 One Infinite Loop Cupertino, CA 95014 MECHANICAL COVER SHEET AP21.01 KSS IL01.1N NO. DESCRIPTION: DATE: DESCRIPTION PERMIT DRAWING DATE 04/08/21 1/4" = 1' Arnold Hom 06/23/21 18 E D.9 D.8 D.7 D.5 D.3 OFFICE A141 OFFICE B115 OFFICE B110 PROJECT NO. 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 SCALE: DRAWN BY: w w w . d a v i d w h i t n e y a r c h . c o m S a n J o s e , C A 9 5 1 2 6 3/ 3 0 / 2 0 2 1 9 : 0 0 : 0 5 P M M1.0 One Infinite Loop Cupertino, CA 95014 MECHANICAL DEMO PLAN AP21.01 KSS IL01.1N NO. DESCRIPTION: DATE: DESCRIPTION PERMIT DRAWING DATE 04/08/21 1/4" = 1' Arnold Hom 06/23/21 18 D.7 D.5 D.3 OFFICE A141 F1 F1 F1 F1F1 F1 F1 F1 F1 PROJECT NO. SCALE: DRAWN BY: 2 1 8 5 T h e A l a m e d a , S t e. 1 0 0 S a n J o s e , C A 9 5 1 2 6 w w w . d a v i d w h i t n e y a r c h . c o m 3/ 3 0 / 2 0 2 1 9 : 0 0 : 0 5 P M M2.0 One Infinite Loop Cupertino, CA 95014 MECHANICAL PLAN AP21.01 KSS IL01.1N NO. DESCRIPTION: DATE: DESCRIPTION PERMIT DRAWING DATE 04/08/21 1/4" = 1' Arnold Hom 06/23/21