Loading...
RM-2021-018 Stamped Plan Set0 C CUPERTINO Case # Approva Approva Signatur mmunity Development Department Planning Division - Cupertino APPROVED RM-2021-018 Application Number(s) ody: Director / Staff ate 09/27/21 Gian Paolo Martire Case Manager SHUK A RESID NCE(AD ITION) as❑ C Lj oIN 7 N (00 CA 95014 GENERAL NOTES: ABBREVAITIONS AND INDICATIONS DRAWING INDEX PROJECT DATA: 1, THE ARCHITECTURAL SITE PLAN IS PR❑VIDED FOR BUILDING A.B. ANCHOR BOLT NTS NOT TO SCALE A-1.0 TITLE SHEET 1. LOT SIZE: 6,439 S.F. AP N 3 69 — 027 — 0 42 AND SITE WORK LAYOUT ONLY, THE CONTRACTOR SHALL VERIFY ON A/C ASPHALTIC CONCRETE NOM NOMINAL A-2.0 SITE PLAN SITE ALL GRADES, EXISTING IMPR❑VEMENTS, PROPERTY LINES ACC. ACCOUSTIC O/C ON CENTER A-2.1 EXIST. HOSE PLANS 2. ZONING: RI-6 EASEMENTS, SETBACKS UTILITIES AND SUBSTRUCTURES, ALL DISCREPANCIES SHALL BE IMMEDIATELY DISCUSSED WITH ARCHITECT. ALUM ALUMINUM OPG. OPENING A-3.0 FLOOR PLAN LAND USE: LOW Density Res . (1 — 5 DU/AC) 2' FINISH GRADE SHALL PROVIDE P❑SITIVE DRAINAGE AWAY FROM BLK C.J. BLOCK COLD JOINT LAM PLAS LAMINATED PLASTIC PL GL PLATE GLASS A-4.0 ELEVATIONS &SECTION 3. CONSTRUCTION TYPE: V— B (N 0 FULL FIRE SPRINKLER) A-5.0 ROOF PLAN & DETAILS BUILDING. CONIC CONCRETE PLY PLYWOOD C-0.0 S U RVAY MAP OCCUPANCY GROUP: R — 3 / U CONT CONTINUOUS RDWD REDWOOD 3. PAD GRADE UNDER BUILDING SHALL HAVE POSITIVE SLOPE TO A C.I. CAST IRON RWL RAIN WATER LEADER 4. M a u l i k S h u K l a, email: m a u l i ks h u kla@yahoo.com MINIMUM OF ONE AREA DRAIN WHICH SHALL BE PIPED TO DRYWELL, DF DOUGLAS FIR SIM SIMILAR 5. BLDG AREA: 4. IRRIGATION SYSTEM SHALL BE DESIGNED TO PREVENT SATURATI❑N OF ELEV (E) ELEVATION EXISTING TEMP GL TEMPERED GLASS T&G TONGUE AND GROOVE EXIST, G AREA: 1 ,055+447(GAR)+363(Family Rm) (A) SOIL ADJACENT TO BUILDING. EXIST EXISTING T.O.C. TOP OF CURB REMOVED AREA: — 3 6 3 (Family R m) (A) 5, ALL C❑NSTRUCTI❑N SHALL EXCEED THE LATEST EDITI❑N OF CODES EXT EXTERIOR T.O.P. TOP OF PLATE ADOPTED BY LOCAL BLDG OFFICIAL. THESE SHALL INCLUDE: THE F.E. FIRE EXTINGUISHER TYP TYPICAL NEW ADDITION AREA: 680 SF. (B ) UNIFORM BUILDING CODE, NATIONAL ELECTRIC CODE, UNIFORM FIN FINISH UON UNLESS OTHERWISE NOTED TOTAL BLDG AREA: 1 SF PLUMBING CODE, AND ALL OTHER HEALTH AND SAFETY CODES, F.O.C. FACE OFCONC VGDF VERTICAL GRAIN DOUGLAS FIR ,735+447(GAR) ❑RDINANCES AND REQUIREMENTS ADOPTED BY GOVERNING AGENCIES. NOTIFY THE ARCHITECT ANY VIOLATI❑N OF CODE IMMEDIATELY, F.O.B. FACE OF BLOCK W.I.C. WALK IN CLOSET (NEW PORCH) AREA: 35 SF (C) F.O.S. FACE OF STUD WC WATER CLOSET „ FDN FUNDATION WWF WELDED WIRE FABRIC PROJECT NOTES 1 ST FL. 18 EAVE AREA 361 S.F. (D ) 6. THESE PLANS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY, THEY ARE NOT EXHAUSTIVELY DETAILED NOR FULLY SPECIFIED, IT IS THE FTG FOOTING TH THRESHOLD 6. LOT COVERAGE (A+B+C+D) 2,578/6,439 = 40.04% RESP❑NSIBILITY OF THE CONTRACTOR TO SELECT, VERIFY, RESOLVE, GALV G.I. GALVINIZED GALVINIZED IRON 0 CONCRETE 7. FAR: 2,182 / 6,439 = 33.89% AND INSTALL ALL MATERIALS AND EQUIPMENT, 0 GRAVEL GYP.BD. GYPSUM BOARD 0 EARTH 8. REMODEL. AREA: 329 s f 7. THE ARCHITECT WILL NOT BE OBSERVING THE C❑NSTRUCTI❑N OF THIS H.B. HOSE BIBB GYPSUM BOARD SURVEY NOTES: PROJECT, THE CONTRACTOR IS SOLELY RESP❑NSIBLE FOR THE QUALITY CONTROL AND C❑NSTRUCTI❑N STANDARDS FOR THIS PROJECT. INSUL INSULATION ® INSULATION 1. THE LIC. SURVEYOR SHALL SUBMIT THE INT INTERIOR ® METAL 8. ALL SUB -CONTRACTORS SHALL D❑ THEIR BEST & PROFESSI❑NALLY TO INV INVERT ® MASONRY CERTIFICATION LETTER OF THE REQUIRED SET COORDINATE THEIR WORKS WITH EACH OTHER. N❑TIFY GENERAL M.B. M.C. MACHINE BOLT MEDICINE CHEST MORTAR, GROUT, CEM PLASTER BACK AND PAD HEIGHT TO CITY OF PRIOR TO V I N I C I TY M A P CONTRACTOR ANY DISCREPANCY & DIFFICULTY, ® PLYWOOD MIN. MINIMUM ® FINISH WOOD FOUNDATION INSPECTION. 9. WHERE CONSTRUCTION DETAILS ARE NOT SHOW OR NOTED FOR ANY MTL. METAL ® ROUGH WOOD PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER N.I.C. NOT IN CONTRACT L­nea°r F—AAve SIMILAR WORK. 2 O DOOR INDICATION ECTION NO. A APPLICABLE BUILDING CODES: Tan-Ghae " TargetQ �Marina Food o 10, TRADE NAME AND MANUFACTURERS REFERRED TO ARE FOR QUALITY - BUILDING SECTION SHEET NO. 2019 CALIFORNIA BUILDING CODE ds Market Apple Stevens a Lazy Dog T oervary Creekl(scol) aResensCree&Bar STANDARDS ONLY, SUBSTITUTIONS WILL BE PERMITTED AS APPROVED BY OWNER, B WINDOW INDICATION _ DETAIL INDICATION 2019 CALIFORNIA RESIDENTIAL CODE n reek aced c � p e r t i n o StevensCreek ales tiger sugar Cupertino � 0 5tevenscreek Blvd 02 Valley P 11, WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 2019 CALIFORNIA MECHANICAL CODE lllam Faria �Pr�4 Ha NO" a ti ary School V 9—fieidDo �b,�AVr Ile QTheBihmareApartmentsp WG S f Cupertino High School n p CAL FIELD VERIFY ALL CABINET SPACE AND FIXED GLASS SIZES, APPLIANCE, FIXTURES, EQUIPMENT ETC. CLEARANCES, 2019 CALIFORNIA PLUMBING CODE PdccAvc s""rsenr PeppnTreeLn p w - - f 0 Low AV* ,vl. w RodriguesAve I 12, THE T24 REPORT IS A PART OF THIS DRAWINGS. ALL SPECS & 2019 CALIFORNIA ELECTRICAL CODE She°yOr 9 Cupertino Library ro 4aMWilsolaPak DETAILS [IF THIS REPORT TAKE PRECEDENCE OVER THIS SPECS & 2019 CALIFORNIA FIRE CODE Range 49Ranch Market � > y o DETAILS OF THIS DRAWINGS 2019 CALIFORNIA ENERGY CODE �h�lYl.. m RANCHO w Pacifica Pr Phll Ln 51 Bette Ave, j R I N C O N A Ave E slriaen of CA 950:14 McClellan ad a frilirldrive 13, DURING C❑NSTRUCTION STAGE, IF ANY ADDITIONAL EQUIPMENT TO BE Sllveratlo upertino, home INSTALLED OF CHANGE ORDERS REQUESTED BY OWNER, THE 2016 CALIFORNIA GREEN BLDG CODE Aqui Cupertino 9 SRatly®ro eel _ 4"nwar nipple Ave CONTRACTOR SHALL NOTIFY THE ARCHITECT OR ENGINEERSSCOPE OF WORKS: J� a "'Iw'"`^ ��`°aIMMEDIATELY,CITY OF CUPERTINO MUNICIPAL CODE Tpumps� �'rIeWOY d Q Hyde Middle 4 q A 6wff 7r` u 'C Me19Y5 Ln S� � The Home Depot "ge % o TP Tea 14, CONTRACTOR'S PROPOSAL INCLUDES ON THE SITE PROJECT MANAGEMENT REMOVED EX. FAMILY ROOM. aemaa°" _ N �ollym°nPaFk, a § Safeway ® "�$ AND FIELD SUPERVISION AS REQUIRED TO MAINTAIN A SAFE AND g-riing�t �d 5 O �P 4 K'flib[Yly. EFFICIENT WORK PLACE, 2. ADDED A NEW FAMILY ROOM AND TWN VED ROOMS. 4 y liemherwaad°r �° o '� � �°' j c 3. ADDED A BAY WINDOW AT LIVING ROOM. Fallen,oaf rn Clarendon Sl_� i 2 ACSstarto pr r�oeLn m y r�mAkl"sp, 2.a - 5 +A_fWPl Nelson S. ailworthc) �eO' ElementarySchool 4 fi%a a 4. REBUILT THE FRONT PORCH Rwr, C A L A B A Z A S ALDERB ROOK gdell Dr t es °cy � NORTH � Mart an Jose Be Anza 19India Cash And Carry sf8 ry GO0 le Ea°"noorwaY J O A Q U I N MILLER Ln Windsor Phyllis Are %t N REV]BIONS BY 04/15/'21 BID & PERMIT DRAWN MC CHECI® MC DATE AS SHOWN SCALE AS SHOWN JOB NO. 81­� A=1 mO OF SIL Ere Em CUPERTII Case Apprc Apprc Signa FEVISIONB BY 04/15/'21 BID & PERMIT D"N CF P?I<ED AS ?HAVN AS TSHMN JOB NO. SHEET A=2 OF SHEETS Em CUPERTII Case Apprc Apprc Signa FEVISIONB BY 04/15/'21 BID & PERMIT D"N CF P?I<ED AS ?HTWN AS TSHMN JOB NO. SHEET A=2ml OF SHEETS 0 C mmunity Development Department Planning Division — Cupertino UPERTINO APPROVED Case # RM-2021-018 Application Number(s) Approva ody: i —9 Approva ate 09/27/21 Signaturf Gjan Paolo Martire Case Manage 00 23'-9' t B O o n 20'-9" 1' 1 I� L O 0) O.I CLONR CLAN AREA CO CH ATThN S: 1 "=10'-0" Material Conservation & Resource Efficiency: A. Annular spaces around pipes, electric cables, conduits or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. B. Recycle and/or salvage for reuse a minimum of 50 percent of the nonhazardous construction and demolition waste in accordance with one of the following: 1. Comply with a more stringent local construction and demolition waste management ordinance; or 2. A construction waste management plan per Section 4.408.2; or 3. A waste management company per Section 4.408. 3; or 4. The waste stream reduction alternative per Section 4.408.4. C. An operation and maintenance manual shall be provided to the building occupant or owner. Environmental Comfort: a. Duct systems are sized, designed, and equipment is selected using the following methods: 1. Establish heat loss and heat gain values according to ANSI/ACCA 2 Manual J-2004 or equivalent. 2. Size duct systems according to ANSI/ACCA 1 Manual D-2009 or equivalent. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S-2004 or equivalent. FLOOR PLAN AREA CALCULATION: SECTION DIMENSIONS AREA A 20.75X15.92 330.34 B 23.75X30.5 724.38 C (GARAGE) 23.75X18.83 447.21 D 5.92+9.58 X1.83 2 14 E 3.67X9.58 35.16 F 6X10.25 61.50 G 29.42X19.33 568.69 TOTAL FLOOR AREA 2,182 S.F. Installer & Special Inspector Qualifications; a. HVAC system installers are trained and certified in the proper installation of HVAC systems b. Special inspectors employed by the enforcing agency must be qualified and able to demonstrate competence in the discipline they are inspecting. C. Verification of compliance with this code may include construction documents, plans, specifications builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which show substantial conformance WALL FRAMING SCHEDULE: 1. All exterior wall shall be 2X6. 2. All interior wall shall be 2X4, (U.N.O. on the structural plans) 3. pulmbing wall shall be 2X6, (framer shall verify w/ Plumber) 4. the wall between the garage and habitable room shall be 2X6. 5. see structural plans for additional wall stud size. 6. Install fire stops along 1 Oft intervals (both horiz. and vert.) along the length of any balloon framed wall above 1 Oft height. Bed room Window Notes: a) Minimum net clear openable dimension of 24 inches in height (R310.1.2). b) Minimum net clear openable dimension 20 inches in width (R310.I.S). c) Minimum net clear openable dimension of 5.7 square feet in area. Grade floor openings shall have a minimum net clear opening of 5 sq ft (R310.1.1). d) The bottom of the clear opening shall not be greater than 44 inches measured from the floor (R3 10. 1). Door Notes: a) FRONT DOOR: At least one side -hinged egress door from each dwelling unit not loss than 3 feet wide and 6.5 feet high with minimum 32 inches width clear. Egress door shall be readily open -able from inside without the use of a key or special knowledge or effort (R31 1.2). b) All doors shall be 8ft height at 1 st floor, U.N.O. Pollutant Control Notes: a) Duct & other related air distribution component openings shall be covered during construction. b) Adhesives, sealants and caulks shall be compliant with VOC and other toxic compound limits. c) Paints, stains and other coatings shall be compliant with VOC limits. d) Aerosol paints and coatings shall be compliant with product weighted MIR limits for ROC and other toxic compounds. e) Documentation shall be provided to verify that compliant VOC limit finish materials have been used f) Carpet and carpet systems shall be compliant with VOC limits. g) 80 percent of floor area receiving resilient flooring shall comply with specified VOC criteria. h) Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. i) VOC of all required materials shall comply w/ Calgreen Table 4.504.1, 2, 3 & 5. Interior moisture Control Notes: a) Vapor retarder and capillary break is installed at slab on grade foundations. b) Moisture content of building materials used in wall and floor framing is checked before enclosure. SUBFLR. VENTILATION: SEE VENT LOCATION @ BLDG ELEV, LIV'G AREA VENT REQ'D: 680/150=4,53 S.F. VENT PROVIDED: USE 8"X14" GALVERNIZED VENT SCREEN (FREE FLOW AREA 0,65SF) 4,53/0,65= 7 TOTAL OF 8 PLACES PROVIDED WALL LEGEND _ = EXIST. WALL TO BE REMOVED EXIST. WALL TO REMAIN ® NEW 2X STUD WALL W/ GYP. BD. 1055 FLOOR PLAN NOTES: OALL INTERIOR FINISH MATERIALS, EQUIPMENTS, PLUMBING FIXTURES AND ELEC. FIXTURES SHALL BE SELECTED BY OWNERS. PROVIDE INTERCOM, SECURITY & VACUUM AT OWNER'S OPTION. O O PROVIDE 18"X24" UNDERFLOOR ACCESS O PROVIDE 30"X30" ATTIC ACCESS, MIN, 30" HEADROOM CLEARANCE. O 7.75" MAX. FOR IN —SWINGING DOORS & 1/2" MAX. FOR OUT —SWINGING DOORS FROM THE TOP OF THE THRESHOLD TO THE LANDING AT THE EXTERIOR DOORS. O CONC. LANDING. 3'X3' MIN. (MATCHED DOOR WIDTH) O BATH TUB AND SHOWER NOTES: A. FINISHED WALL W/ NONABSORBENT SURFACE UP TO 72" ABOVE FLOOR B. TEMP. GLASS ENCLOSURE, SHOWER DR. SHALL HAVE 22" CLEARANCE C. PROVEDE FIBER —REINFORCED GYPSUM BACKERS (OR APPR. EQ.) OCUSTOM TUB WITH CERAMIC TILE SHELF AND EDGE, PROVIDE ACCESS PANEL AT MOTOR SIDE. O ALL EXTERIOR WOOD DOORS SHALL BE SOLID CORE WITH WEATHER STRIP. C) O C) O W O 0 7 REF. N. 20' F.Q.B. PROPOSED FLOOR PLAN S1/4.._1._0.1 FEVIBIONB BY 04/ 15/' 21 BID & PERMIT DRAWN MC CHECKED MC DATE AS NOTED SCALE AS NOTED JOB NO. BHEET A-3.0 OF SHEETS Case Apprc Apprc Signa REVISIONS BY 04/15/'21 BID & PERMIT N 0 N o _ M I iQ � N _ U W � Jib N SAP J J C0 W z Q a � A ct z � E cl) Q Qj W W O � W W � � Q � � W DRAWN MC CHECKED MC DATE AS NOTED BcA�E AS NOTED JOB NO. BHEET A-4.0 OF BHEETB Em CUPERTII Case Apprc Apprc Signa FE/ISIONS BY 04/15/'21 BID & PERMIT DRAWN MC CHECKED MC DATE AS NOTED SCALE AS NOTED JOB NO. SHEET A-5,0 OF SHEETS C mmunity Development Department Planning Division — Cupertino CUPERTINQ APPROVED Case # Appro� Appro-, SignatL SHUKLAR RESIDENCE 851 BETTE AVENUE CUPERTINO, CA APN: 369-27-042 W E C & A S S O C I A T E S 2625 MIDDLEFIELD RD k658 PALO ALTO, CA 94306 TEL: (650) 823-6466 FAX: (650) 887-1294 LICENSE STAMPS AND SIGNATURE L.6235 ♦�` 9 �F CA4lFp�' ISSUED DATE: JAN 23, 2021 SCALE: 1"=10' DRAWN: BG JOB: 10078 SHEET TITLE: BOUNDARY &PARTIAL SITE SURVEY SHEET NO. coo WEC